Loading...
HomeMy WebLinkAboutVAIL VILLAGE FILING 7 BLOCK 5 LOT 4 PRE 2000 REPLAT LEGALQucstions? O,n. Planning Staff at 479-2 l2{l APPLICATION FOR DESIGN REVIEW APPROVAL CENERAL INFORMATION This application is lbr any projcct requiring Dcsigrr Rcvicrv approval. Any projcct rcquiring dcsign rcvicw ntust rcccivc Dcsigrt Rcvic:, itp;:o','al pri ol to subnrittrrtg tbra building pcrnrit. iol slle(;llc iir1,.r:riratiou. scc thc subnrittal rctluircnrcnts tbr thc particular approval that is rcqucsted. Thc application canuot be acceptcd until all thc rcquircd intbnnation is subnrittcd. Thc projcct nray also nccd to be rcvicwed by thc Town Council and./or thc Plauring and Environrncntal Cornnrission. Design Rcvicw Board approval cxpircs onc ycar aftcr final approval unlcss a building pcrmit is issued and construction is startcd. A. DESCRIPTION OF THE REQUEST: u.LOCATION F PROPOSAL:I}LOCK:FILING: PHYSTCAL ADDRESS:,J( (C:ontact c Co. Asscssors Ofticc at 970-32tt-tJ640 tbr parcel #) TOI'//N OFVAIL c. D. E. F, c. PARCEL #: ZONING: NAME OF OWNER(S): MAILINC ADDRESS: OWNER(S) SIGNATURE( NAME OF APPLICANT: MAILING ADDRESS: H. enoNe:.?2 14O e5# TYPE OF REVIEW AND FEE: E Ncw Construction -$200 Construction of a ncw building. lncludcs any addition whcrc squarc footagc is addcd to any rcsidcntial or conrmcrcial buildins. tr Addition -$50 f Minor Altcration -$20 lncludc.s minor changcs to buildings and site inrprovcmcnts, such as, rcroofing. painting, windorv additions. landscaping. fcnccs and retaining walls. ctc. E Conceptual Review - $0 For any application where thc applicant wishcs to mect lvith Dasigu Rcvicw Board to dctcmrinc whcther or not thc projcct gcncrally conrplics with thc design guidclinas.,Thc DRB docs not votc on conccptual rcvicws. DRB fees arc to bc paid at the timc of submittal. Latcr. whcn applying for a building pennit. plcasc idcntify thc accuratc valuation ofthe projcct. Thc Town of Vail will a .iust thc fce according to thc projcct valuatiop. PLEASE SUBMIT THIS APPLICATION, AI-T, SUNUITTAL REQUIREMENTS AND THE FBE To THE DEPARTMENT oF COMMUNITY DEVEL0PMENT, 7s SOUTH FRONTAGE ROAD. VAIL, COLORADO 8I657. PHoNE: /: ? 142 l4 Jan 98 George Ruther Town of Vail Community Development Re; May Residence Minor Alteration ARC H ITECTS George, Per our discussion, attached is additional information for the current Minor Alteration submittal. Below is a narrative corresponding to the attached drawings, which are in addition to the exterior lighting issues you already have in you possession. Some of these issues pertain to either the original house or the recently completed cabana. But as we have done in the past (because of one owner, and the lot line abandenments) we are submitting this as one property. There are five main issues in this request; l. Exterior lighting (drawings and narrative previously submitted). 2. Addition of exterior stone veneer at existing house. Re; attached drawings "4 - Main Level Floor Plan", and "13 - Exterior Elevations". 3. Addition of "man-door" in existing garage door at original house. Re; drawing " I 3 - Exterior Elevations. 4. Extension ofexisting fence along new cabana from existing house. Re; drawings "l - Site Plan (existing house site indicating location of existing fence) and A10l - (new cabana) Site Plan. Existing and new fence design indicated on drawing "l- Site Fence". 5. Add stone/slab on grade patio outside billiards room, north side of cabana. (Per previous submittal landscaped area required is 9,900 s.f., existing is 10,422. Re; attached previous DRB application). If you have any questions or comments please call. Thanks again, George! D&c <wE/*"-*, Dale Smith Architect Ll95l5\DOC\CRol l498.WPD PlanningaArchitecturetlnteriors 1650 East Vail Valley Drive Fallridge C-1 . Vail, CO 81657 r fpb@colorado,net . fax (970) 476-4901 . (9701 476-6342 lbrrurEDore o 8 Egf FIL T COPY 5. A request for an amendment to Section 18.54.050 J (Design Guidelines - outdoor lighting), to allow for the exemption of low wattage lighting from the outdoor lighting regulations. Applicant: Roy & Paula May, represented by Dale Smith/ Friizlen,Pierce, Briner Planner: Lauren Waterton Dominic Mauriello gave an overuiew of the staff memo and explained that this was lo allow low level lighting to make a property safer, after lhe DRB final review. He then explained the new language. Greg Moffet asked if the applicant had anything to add. John Schofield thought the 25 watt output was on the low side and he thought it should be in the 40 watt range. He said stairs typically have wattage in the 40-60 watl range. Gene Uselton said this was a sensible proposal. Greg Amsden said he was in favor of this, as it was a safety issue. Ann Bishop had no comments. Diane Golden agreed with the safely issue. Greg Moffet said he agreed with the safety issue. John Schofield made a motion for approval with a change in the language to include a maximum initial lumen output of 400 (or equivalent to a 40 walt bulb). Gene Uselton seconded the motion. The molion passed by a vote of 6-0. Planning and Environmental Commission Mnutes October 27 . 1997 rllcrrlein Consun,n? Engineers Consulting Geotechnical Engineers 12364 W. Alameda MAIN OFFICE (303) 989-1223 (303)989-0204 FAX Pkwy. Suite 135 . AVON (970) 949-6009 (970) 949-9223 FAX Lakewood, CO 80228 SILVERTHORNE (970) 468-6933 (970) 468-6e39 FAX August 5, 1997 George Shaeffer Construction Company P.O. Box 373 Vail, CO 81658-0373 Subject: Excavation lnspection for Proposed Pool tot4(1067 Ftarmigan Road) /v\h/ Pf9tOANCA Vail, Colorado Job No. 97-209 As requested, a representative from our office inspected the soil exposed in the proposed pool excavation at the subject site on July 28,29 and August 4, t997. The purpose ofour inspection was to veri! that the exposed materials would safely support the proposed pool. 1'he depth of the excavation varied frorn 2.0 to 9.0 feet. The materials exposed in the bottom of the excavatiorr consisted of 1.5 to 5.0 feet of crushed rock. Beneath the crushed rock, the subsurface tnaterials consisted of a moist to wet, dense, gravelly, sandy, silt with some cobbles. The exposed soils and crushed rock within the excavation were compacted in accordance with our recommendations. ln our opinion, the natural soils and the crushed rock will safely support the proposed pool. Our opinion is based on the natural soils remaining unsaturated. We appreciate the opportunity to provide this service. lf we can be of further service, please contact us. S incerely, K.OECHLEIN CONSULTINIC ENCINEERS William H. Koec President SBM/jt (2 copies sent) cc: Town of Vail ri, P.E. TDL'N OF UBIL COI'I-DEU r€rcfilng rFqueFt rpE03-479-2412*ruL 1le6 9:24 No .0O2 P.O2 tt lqrs/trarn read lhe - Hrzard RtPort, datsd f fle prepared by lrom the oonoluelona thet tho FopoBod bulldlng ls localed In a hazard zone, and there lr lhe Dobntlal hazard ol -hazard zrne, utd lr |he pomnilal hazard ol - house. cat,3lng damege, We c€ preparad to acospl thcBs lacls and Bulldlng Drpqrtnant gnnt gr p.rmiL \ \^\ STATE OF COLOFADO COUNTY OF My oommlsslon cxplruc: ) ) rc. ) cnht'|rur:rd 07/r8/96 09:08 rTXIRX N0.4694 P.002 JAN_'B_9?F.POM : Tc|t,-C: O.I'-DEt, -DEF T.I D . g?O4?Sl24S2 . t.trGAL DESCRISI'ION: Lot HeighL fotal GRFA Primarfr GRFA Secoadary GanA . Setbacks SiLe Cowerage I.arrd,scapins e- Le'4r'- {D% Retaining waL1 Heighes .. Park-ing Ga-r3g,'g Credit Driwe: Complies with T-O.v. Water Course Setback Do Finish Grades Exceed EDvj. ronmen tal_,/Ha "ards : '!,'{t?* * qFcp_lD.^/?Z a,y- 3'/6, € Regra PermiLled. Slope 8+ proposed stope--16 ,[ Lighring Ord,inance (}z- -=4o ncI Yes ItP< &.- Ntll.. . NO Does Lhis rrcru€sl irrvuive a ZjO Adciicioa? +p _.How much or Cne artovred. aso aoailion is uFea-mrhis reguest?.."Q.....'-.,:. Previous conditions of approwal (ctreck properElr fi].e): ZONE DTSTRICT ?/S PROPOSED GSE ?I= roi srze '\,gyrd I - =l& * Brrrr,DABr,E roT AREA AI1o!ir.qg <=orltEd e*iSFrpg. pfopo.Feg TqFiL =;3' t-at <{tOt ZS.qO- + 4zs =_Z,IEF t,40 + gs. -J_% PTONE Sides Rear 7b% view Corrid,or Ehcroachment; yeg zci,' 15'15' -3.3oO +- { 3oo) (5oo) ts oatwJ,+5l_ NO t/ l. ) Flopd Plain r-,!t - 2J Percenr Slope (< > 3Ot) I 3) Geo.l.ogic ttazardsa) S$ow.Avalanche ,-JO.b) Rockfal]-c) DebrisFrffi 4) wetlands No 43qry!. oE 5Je 5J&4 oL 745 oE 7A, +Z=tAa--. H-pe (4Ju8Y,s-S =- 7,%l .\ 0t /16/97 I7204 TXIRX N0.656? OIL P. 001 Nicholas Lampids, ph.D. CONSULTING GEOLOGIST P.O. BOX 2 SILT, COLORADO 81652 Phone / Fax (970) 876-5400 (24 HOURS) July 3, lgSa Dale Smith Fr i tz l enPi erceBri ner 1650 E. Vail Valley DrlveSuite C-lVall C0 81657 REt Hazard Evaluation I LO67 ptarmigan Road, l'lay Residence Dear l'lr. Smi th I I vieited the above referenced home in Vail recently ior purposegof a geologic hazard evaluation, especially as it pertains torock {all potential . As you know thie hazard ig noted on theTown o{ Vail's ,naps as encroaching onto the property, wtth"l"ledlum" designation. In addition, debris flow and aval anchehazard are mapped as extending to the south side of the road.The expansion, aE ghown on your mapts (where the western home willbe razed), is on the north Eide of the road, further {rom thesource o{ rocks, and out of the other two zones. The topography ig such that rocks will tend to stop in the heavyaspen growth on the Eolrth stde of the road. The outcropping ofrocks above the lot is minor and quite a distance from thishouse. I saw no large rockE near this home. Even though it isnot likely that mud or snow can reach the proposed expanlion, ttwould be prudent to landscape and grade the front (eouth) side ofthe property to preclude material from approaching area6 ofvulnerability. In addition to the walle shown, perhap- the entrydrive could have a high point in it at about the property line toprevent material from entering very far. The near gide of thehome (front) should be planned accordingly. The'-property doee lie in a geologically lrengitive area, butdevelopment, or mltigation in front of the home, will notincreage the hazard to other property, or structures, or topublic righte-of-wayr roads, gtreets, .easements, utilities orfacilities or other properties of any kind. If there are f LrrtherqueEtions, pleare contact me. Si ry:erel y, ///I --'t/ ,t-pq ".y'vt\Nicholarr f,a,npi ri sConsulting Geologist AA/13/t9% t?129 FR0[{ Kocchlein Consulting Engr T0 LAAS61'S,?A4?SZ4SZ p,Az ,ll..il,*1{,(.o.,0.-o.;-- William H. Koechlcin, p.E. Prcsidcnt sBIWjt (2 copics scnt) AVON (970) 949€009 (970) 949-922r F$( (97p)4OE{q}3 (szo1156* ro Ktch lei n ConsuftintEngineers Consultln g Geotechnic-al Englnecrs 12i164 W. Aemede Plffy. Suib 135. Ldcrvood, GO MAIN OFFICE (303) 989-1223 (303) 989-0204 F$( August 12. 1996 Shaaffer Constnrction P.O, Box 373 Vail. CO S1658 Subject: Excavationlnup*tion Proposcd Residence Lor 4 (1067 prarmigan Road) Vail. Colorado iob No. 96-193 As rcqrrcsted. a reprcscntative fifir otrr officc iuspected thc fpundation malerials erpo;gd in tfie oonrnlctcd cxqav*tion at thc subjcct sitc uu Arrg,ust g, 1996, The pur.puw uf our irEpsctign w{s to vcrifi'that thc cxposud materials sauld safl:l1, support a sprcad footing ftundrtion ry$cm fur thc proposed n:srdeucc. 'flrc dcpth of the cscavation varied betrlscu 4.0 to 10.0 feet, The rnateriats arpo*d in thebottort of tlrc nrcavation frr the residcncc. consistcd of a densc to !€ry dcnrc- rtrdv, silt erdgnvel with sorne cobblcs. The exposed soils rvithin thc et(cniilion wctr compr.ted in ace,ondalrec with uur rvstmmendsions. ln our opinion, thc exposed soils will sdbty'srppon a !F!!d fgoting foundation s;vstrm dcsigncd for i me{mun ailo"rtt, soil bahg'ffin of 3,000 psf. We apprcciatc the opportunity to providc this sen,ice. lf nc can be of furthcrscrvicc, plcase COnt Ct us. Sin<xrclr'. KO ECHLEN CONSULTII{O ET{GINEERS g0iEn TOTFI- P.Oz A8/13/L996 t?tZg FR0l'1 Koechlein Consulting Ensr T0 t@A56t97?,4792452 P.@1- rtcnbin Consultin?engineers Gonsulting Geotechnlcal Engineers 12364 W. Alrrldt Pkry. Sulb ls. Ldrwoorl GO t0421 MAIN O"FFICE (300) 989-1223 AVON SILVEHIHORNE (303) 98*0204 FAX (g7o) e4s9u' FA)( (97!)468€eX! (97O) C5g!693e pN( rrxr',,-;t-f ,. --i"iri ' 7q{ L robNo. 4(6.tti3 Item(s): Purposc: (e7q949€0G i\ o. I t,.r L\ you requcstcd /-_ ror lour lntonnatrcn fot your approval twiew and raurn rrply to scnder Other (ree ranrks) Remarkt: Copics: ", Dl ?ur,..*--- t, "lqt IOV,l'SsO '/ r{r, rr . DESI APPLICATION - TOWN 1 DATE RECEIVEDI DATE OF DIIF MEETING:****r*trr*** BE DE|/.OEff, r . *r-:e*{!:.,!,t,111r-t!.r,,,rf .$r*f ' *ri***t**r, A. Fl D. a meets and bounds legal l on a separate sheet and aLtach tYtAn .r1. li 1.fldtlZONING: NAME OFMailing APPLICANT: Address: {iul:t,Mn IJ NAME OF OWNER(S) APPLICANT'S Address:REPRESENIATTVE:NAME OF Mai J. ing Phone sr Mailing Address: APPLICATIONS WILL NO? BS PROCSSS.ED WITHOW ORhIER'S STGIVE?URE I. Condominium Approval if applicable. ,1 . DRB FEE: DRB fees, as shown above,\ are Lo be paid at. Lhetime of submit.tal of t.he DRB,applilaeion. Later, whenapplying for a-buirding permit,-plbase idencify t,he accurat,evaruaLion of [he proposal . The town of vait wirt aajust. Ltrefee according to the table below, to ensure the correct feeis paid. - FEE SCHEDULE: ,tr Y VAIJUATION t\ + .|n ,t ra.iv 9 rvrvvv FEE O ZU. UU $ s0.00 $100.00 $200.00 $400.00 $s00. 00 ONE YEAR AFTER FINAI ISSUED AI{D CONSTRUCTION $L0,001 -$ 50,0OO$ so, 001 - $ 1s0,0oo $l_50,001 - $ s00,000 $500, 001 - 91, 000, 000$ Over $1, 000, 000 DESIGN REVIEW BOARD APPROVAITTEXPIRES APPROVAIJ IJNI'ESS A BUTLDING PIiR}'IT ISIS STARTED. il DESCRIPTION: * U"r Construction (g200.00) ___Minor Alrerarion ($20.00)Addition ($50.00) . conceptual Review (gO) ADDRESS z lcb'l f"i.;:t,(ttttw I+); I,EGAL DESCRIPTTON: IJoT ft 6 BlockSubdivi.sion | ,{tllage If property is described bydescription, pldase providlt.o this applicat.ion. PAID: S Z@,OO 1. ,/ t-' .NAI{E OF PROJECT:$ LEGAL DESCRrpTron: :.,6t k ly(zsLocK .: 4 S?REET ADDRESS : lCb l l)l ,t ,, ^tn:,, . The following informaEion is required Review Board before a final approval A. BUIIJDING MATERIALS: TYPE oF(/yWiZ*l FtNleg ArlO f_Wrr+1G_, SUBDIVTSTON f:,i, f or submi t t.aI can be iiven: MATERTAIJ to Lhe Design APre4 €fr",, | fr{, l7;';' 6y;* -,,ffi,bf) (/* .74e,4<XA) ,/s/0 fAttT r-'v tr4 aE/ 53 &urc+t / ql t'EIEE{<filAzlA t z-to^i zt a,r' t_- I rze-iS Zza Ud <:xZ @rd 6/D/,QCt Zl ,a<'D/ Lrl ,!a!fc/r 9/2^j) COLOR Roof Siding Ot.her waIJ Materials Fascia Soffits Windows Wrndow Trim Doors Door Trim I{and or Deck Rails FIues Flashings Chimneys Trash Encl osures Greenhouses Ret,aining Walls Exterior Liqhting Ot.her LANDSCAPING: ,</a /<JA &9tEtcg =LrsT_gE_ltaEERTALS Name t PI,ANT MATERT.P'" PROPOSED TREES AND SHRUBS ao* or, 11, ouanLlE,v srze...- ofs]'ze /T to F4p-*, TTJAT- *yt'rtNA &H:ryF>'',) FoeUlu S rtW ut o rcA A#-r\) S.l nre ln L,LclS,t r LtLAc rous t.rees is 6proposed shrubs. Tvpe W'4/zt' 5og.* Minimum size of shrubs is Sguare Footaqe *Indicate ecJ, m * * Indica t.e5 qallon. GROUND. COVERS Qnn SEED TVDI' OF IRRTGATION TYPE OR METHOD OF EROSION CONTROL c.LANDSCAPE LIGHTING: If ext,erior liqhE.ing is proposed, pleaseshow t.he number of f ixcures ind f ocat.iois orr'a '".furat" lighting plan. fdenrify each fixEure from t.he tiqhCing ptan 1l lhe space below and provide rhe height above giade, -t.ype ofligh-t.proposed, lumen outpuL, ruminous area and a cut sheeL ofthe light. fixture. (Section 19.54.050.I) D.OTHER LANDSCAPE FEATURES (reLaining walls, fences, swimmingpools, eEc.) prease specify, rndiiate heighcs oi'tecaininiwalls. Maximum heighr ot wllls wit.hin the fronc set,back is3" Maximurn heighu of warrs ersewhere on the prop.tcy is 6,. F&na-t oF TTJE fAr/b Ar.-rr:> T7-j€ Fac- 9F'rry fpt/r1,J/.. /Ot / frAt'q'n r'.;irqttr futr-qo*t oF FE4foe) ft& [Jta:'tE. A /4 .8 Pgr'P6x24u F€<t-* DEPAR?MENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED DEMO. OF PART/ALL BUDG. Job Address: 1067 PTARMIGANLocation... : 1067 PTARMIGAN ParceI No.. : 2101-092-09-002 Project No. : PRJ96-0095 APPLICANT SHAEFFER CONSTRUCTION P O BOX 3?3/ VArL CO 81658 CONTRACTOR SHAEFFER CONSTRUCTION P O BOX 373, VArL CO 81658OWNER MAY ROY & PAULA 4508 W MONTROSE, CHICAGO IL 60641 Description: DEMO OF EXSISTING RESIDENCE Occupancy: R3 Single Family Residence Type Construction: V NR Not in tablel Type Occupancy: Valuation: 12,000 Add Sq Ft: RD Status...: ISSUEDRD Applied. .t o6/07/L996Issued...: 06/20/1996 Expires..: 72/17/1996 TOWN OF VAIL 75 S. FRONTAGE ROAD vArL, CO 81657 97 0-479-2138 ON JOBSITE AT AI.,,L TIMES Permit #: D96-0007 Phone: 3038455656 Phone: 3038455656 Fi reotacc Infornation: Restri cted:flof Gas App l, i anccs:#of Gas Logs:fof uood/Pa t tct: *ffi**ffi*Jiffi*M*#ffiffitrffi FEE SUIIMARY ffi**rrjr Bui Lding---->165.00 Restuara:rt Ptan Revi ey--).00 Total catcutated Fccs---> 375.25 Ptan Chcck---> 107.?5 DRB Fee--------- Investigation> .00 Recrcation Fee----------> .00 Total PlrDit Fcc----) 375.25[i f,t cal,t---> 3.00 cleEn-up Deposit--------> 100,00 Payncnts-----------> 375.25 TOTAL TEES------ tr*ffi**ff '|/.*'Hrffi ffi ffr|t#(ffiffii|Hrftr*ffi ***ffi *ffi ffi ***ffi*ffi ItEm: .O51OO BUILDING DEPARTMENT DeDT: BUILDING Division:06/.07/1996 CHARLIE Action: NOTE PLANS TO CHARLIE06'/0.7./1996 CHARI,IE Action: APPR CHARLIE DAVISIt'em:'.O54OO PLANNING DEPARTMENT DeDt: PLANNING Division:06/07/.1996 CHARLIE AcIion: NOTE PLANS TO LAUREN06'/20'/1996 LAUREN Action: APPR I!e{ri',9t990_EIBE qEPARTMENT Dept: FIRE Division:06/07/I996 CHARLIE Action: AppR N/AIte.fni'.05500 PUBLIC WORKS ' Dept: PUB WORK Division: Q6,/.Q7/.1996 CHARLIE Action: NoTE pLANs To LARh.t po6'/20/t996 CHARLIE Acrion: AppR FOR LARRY p Itetii'.05?Q0_ENy_IBqNMENT+L HEA_LTU -_ ,_ Depr: HEALTH Division;06/07 /L996 CHARLIE eciionl-epFn n/eItem:'.05900 LIQUOR Dept: CLERK Division:06/07/1996 CHARLTE Acrion: AppR N/A f**rrfi **rikftt*H<ffi ffi ffi*tr**t*trkf ***ffi ffiffi ffi*ff fi rlr*ftt*rrt*t*rtsi See Page 2 of this Document for any conditions that may apply to this pernit. DECLARATIONS I.hereby acknowtedge that t have read !\is appLication, {itLed out in ful.t the infornation required, coftpl,cted 6n accurate plot PLan, and state that att the information provided as required is correct. I agnee to compty vith the inforMtion and ptot i:l,an,to conPly with aLI Tovn ordinances and state [aws, and to buitd this structurr rccording iothc Town's zoning and subdivisibn codes, design revie!, appnoved, uniforn. Bui tding Code and other oPdinances of REOUESTS FOR II{SPECTIONS S{ALL BE ITADE TI'ENTY-FOUR HOURS IN ADVANCE BY Scnd Cl,ean-Up Deposit To: GEoRGE SHAEfFER CoNSTRUCTIoN CONDITIONS as of 06/20/96 Permit Type: DEMO. OF PART/ALL BUDG. Applicant: SHAEFFER CONSTRUCTION 3038455656 Job Address:Localion: ].067 PTARMIGAN RD Parcel No: 2101-092-09-002 Description: DEMO OF EXSISTING RESIDENCE Conditions: 1. FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE STARTED.2. FIELD II{SPECTIONS ARE REQUIRED TO CHECK FOR Town appt icabte thereto. 3E oUR oFFICE FRol 8:00 A[ AND OIINER ******************************************************************************** Permit #: D96-0007 Status: ISSUED******************************************************************************** Applied: 06/07 /L996Issued: 06/20/t996 To Expire z I2/L7 /t996 ANY WORK CAN BE CODE COMPLIANCE. **************************************************************** TOWN OF VAIL, COLORADO Statennt**************************************************************** Statemnt Number: REC-0159 Anount: 375,25 06/20/96 15:34 Palrment, Method: CASHCK Notation: *32495 Init: CD **************************************************************** Permit No:Parcel No:Site Address: Location: This Payment Account, Code 01 0000 41310 01 0000 4L332 01 0000 22002 01 0000 41336 D96-0007 Type: A-DEMO 2LO1-092-O9-002 1067 PTARMIGAN RD ],067 PTARMIGAN RD DEMO. OF PART/ALL BU 375.25 375.25 .00 Amount 165.00 ]-07 .25 100 .00 3.00 Total Fees:375.25 Tota1 ALL Pnts: Balance: Description BUILDING PERMIT FEES PLAN CHECK FEES CLEANUP DEPOSITS WILL CALL INSPECTION FEE f ::ffi:i;;:il.sT::',f :fi t'''ff; "!*"coNsrRucr;EpARcEr #; gl)l O?9 n?oaA PERMTT AppLrqAT/roN FoR,,t ' '- '' oerri--A/A-/qb [ ]-Building 6 l-Plunbing [ ]-Electricat g ;-uechanibal 1Srn"" D,r'rl,-Jdn rob Nanes fltUny fu{t- I' Job Addressz /AZ Pttqnb,*a Pa/, Lesat Descriptionz rctffialock;l sithng 7 sulyr;$w, ua,,, ail+. owners Nane: R\,+P"I,.U Y1* Address:ttn Qt*eru;g,o"a FA p:n.q76-g\t7 Architect:Address: ' F.OoLp Ung AL p1n. .176 -bgtl General Description: Work Class: [ ]-Ne!r [ ]-Alteration [ ].-Additional t l-Repair t4-o1-fle+b,"ohbt Number of DweLling units, I Nunber of Acconnodation units: *: : :- :ff #A: -$ ?.;i7.:::: : ; . : .' App 1 i anc e s- Ga s Los s- wood/ Pe 1 1 et- l\* " * * " " &l W| -ffi t @ og D qe*- ELUATIONS * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * BUTLDTNG: | . :.lK Er.EerRrcAL: $ orHER: $pLrruBrNG: , ./ I)l' MECIiANTCAL: s- roiaii - t/ 7'--,-l*******'r*****!r*****+*_****** coNTRAclgR rNFoBl,fATroN ****!r********************* *f Eeneral contracton O,o,"o.-sApr{p.r,(le,,J-6-. Town of vail neq. No;titE- Electrical. Contractor: -/- | > Town of Vail Req. NO.Address: f pboneNumber: Ptunbing Contracto". l4f\ Town of VaiI Reg. No.Address: --'-- phone Number: --_ --|- T::!iii:"I contractg4 rown of vait Ree. No.Address: ./ - bL^i^ r'..-r-^-- z! '!Y'-Phone Nuraber: ******************************** FORBUILDING PERMIT FEE: PLWBING PERUTT FEE! MECHANTCAI, PERMIT FEE: ELECTRICAL FEE: OTHER TYPE OF FEE: DRB FEE: oFFrcE usB ************* * * * *********** **** BUTLDING PI"AN CTTECK FEE: PLUUBTNG PIAN CHECK FEE: I4EC1IANTCAL PI,AN CHECK FEE: RECREATION FEE: CI.EAN-UP DEPOSTT: TOTAL PERI'IIT FEES: BUTLDTNG: STGNATURE: ZONING: STGNATT]RE: CLEAN UP DEP,OSIT IEFTIT{D TO: o CEORCE SHAEFFER PO. Box 373 Vail, Colorado 81658 (970) 845-56s6 (e70184s-Hllddd Town of Vail Office of Community Development 75 SouthFrontageRoad Vail, Colorado 81657 RE: Demolition Permit Application 1067 Ptarmigan Road Vail, Colorado Dear Sir or Ms: Enclosed is an application for a "Demolition Permit". Our intentions are to remove the entire structure along with all miscellaneous improvements such as patios, driveways, etc. as soon as possible. A new single family residence will be constructed in its place. The tentative schedule is for this project to commence by July 15, 1996. According to the architect, Bill Pierce, he anticipates having the Architectural and Structural plans for the new residence available for me to apply for a Building Permit by June 24,1996. Prior to demolition, we will be erecting a 7' to 8' high screen fence along the 3 property lines. Other than trucks having street access in order to haul out the debris, we will not be doing any work within the Right-A-Way area at this time. An Estimated cost for the "Re-Claiming or Re-Vegetation" of this site is as follows: Importation and placement of approximately 1,100 C.Y. of Structural Fill & Top Soil (Cost estimate by Long's Excavation) Re-seeding of disturbed area (approximately 4,500 SF) 8,300.00 (Cost estimate by Fitz Landscaping) 1,360.00 Miscellaneous (labor for fence removal, clean-up) 500.00 Total: $ 10.160.00 Deposit amount Due: ($10,160 xl25Yo) Your cooperation regarding this matter is greatly appreciated. $ 12,700.00 Sincerely, GEORGE Enclosure cc: Roy and Paula May FFER CONSTRUCTION COMPANY FILE COPY 75 South Frontage Road Vail, Colorado 81657 970-479-213V479-2139 FAX 970-479-2452 April 9, 1996 D ep artment of Community D evelopment Bill Pierce Fritzlen, Pierce & Briner P.O. Box 57 Vail, CO 81658 RE: Proposed May residence, 1067 Ptarmigan Road Dear Bill: Thank you for appearing before the Design Revierv Board on Wednesday, April 3, 1996, with the proposed May residence, located at 1067 Ptarmigan Road. Design Rwiew Board As you are aware, the Desigt Review Board conceptually reviewed the proposed May residence. Upon completion of their conccptual review, the Design Review Board's only questions or concerns were with regard to the proposed relocation of the existing trees and the addition of some form of architectural element on the long expanse of roof on the north elevation. The Desigr Review Board indicated that the four proposed spruce trees adjacent to the property on the golfcourse be moved back onto the May property. The Design Revierv Board felt thc best location for the relocated spruce trees would be immediately adjaccnt to the pool wall and fence along thc north property line. It was felt that thc sprucc trees placed in this location would act as a good buffer between thc golfcourse and the proposed pool deck. The Design Review Board also had concerns regarding the large expanse ofroofon thc north elevation of the building. It was felt that some form of architectural projection or feature be added to help break up the roof, Each of thesc concerns needs to be addressed by yourself or Dale Smith at the time of final review of the proposed May residence. Zonins Analvsis Thc Communify Development Department staffhas compleled a Zoning Analysis of the proposed project. Each of the items listed below addresses an issue which must be resolved prior to final review by the Design Review Board. Final review for the May residence is tentatively scheduled for April 17, 1996. The following items must be addre.ssed: l . As drawn, the garage portion of the building is in lhe front setback. If you do not propose to have the building locatsd in the front setbach please make the appropriate changes. Ifyour desire is to have the building in the fronl setback, please complete and submit an application for a front setback variance for review by the Planning and Environmental Commission. {; *tn"uoru"^ Z. Thc proppscd rctaining rvalls on the southcast corncr of the residence exceeds 6' in height. Pulsualt fo Cffiei f e.SS, Supilemental Regulations, retaining walls shall notcxceed 3' in the front setback, or O'lnyt"tre.c else on thc proPerty. As proposed, thc wall is 7'87' tall' 3. please label the crawlspace on Shect 4,-201 as having a head hcight of 5' or less from the carth to the floor joists above. 4. It appears that the finished floor elevation ofthe exercise room shown on Sheet 4-204 is inconecl Please rnake thc appropriate changcs as necessary' 5. pursuanloSection t8.l3.l0l,LandscapingandSiteDevelopment"atleast60%ofeachsiteshall be landscaped. As proposed, 58.6% of ihelot remains in landscaping. Approximately 218 sq. ft. of landscaping must bi adaed to the proposcd landscape plan. Please make the appropriate changes as nccessary. 6. In order to determine the proposed building height, please indicate all roof ridge elelations on the site plan. Addirionally, ail eiisting and proposed contours should be shown beneath the proposed structure. 7. plcase indicate the proposed top ofwall height ofthe pool privacy fence along the front properfy linc. As I believe youire awarb, fences, hedges andwalls cannot exceed 3'in height in the front setback. 8. In order to determine whether the proposal complies with the Outdoor Lighting Ordinance, please show all proposed exterior tighs on the sitc plan, as well as the appropriate building elevations. Based upon your lot size of 16,500 q. ft., seventctn exterior lights are permitted on the property. 9. prior to the issuance of a Building Permit for the construction of the proposed May residence,-a revocable Right-of-Way Permit will need to be issued for the improvements shown in the public right-of-way. 10. To determine the limit of disturbance for the demo/rebuild, please indicate on the site plan and the landscape plan, a proposed limit of disturbance. Additionally, thc limil of disturbance should be delineaicd'on tire property during construction with a construction fence to protect the undisturbed , areas. I l. According to the proposed site plan and lowcst level floor elevation, it appears a palio is necessary on the noih side of tfie Uuilding. As shown, elevaiion grade 54 intersects the building at a point approximately rvhere thc lowesl levcl of floor clevation of 52.5 cxits the building. Please make any changes that are necessary. Shoutd you have any questions or concems with regard lo the information addressed in this letter, as always, pf .*. Ao not hesitaie io give rne a call. I can be reachcd most easily during regular office hours at 479- 2145. Sincerely.Lt c-,fu^f PaJ'4- Gcorge Ruthcr Town Planner cc: Dalc Smith "liBiJfHfflllrfr Category Number 6 Projec't Name: Building Name: Project D€scription: Owner, Address and Phone: n cnite"V6t"c<)Rodre6s and Phone:f----' Lesal Descripti . tror4 I "J/Ftock 5 suouivision \/a,, I Vil/{e, Jh Zone District 4 S Projec{streetAaaress: l[b1 ?t'*ant,7*L Q^*t Comments: Motion by: Seconded by: p(nnnrovat fl Disapproval ! Statf Approval Conditions: ,.-'t --I| t./ t tv_,l Town Planner o*' df nfql DRB Fee Pre-paia h @rja). oa FritzlenPierceBriner 1650 E. Vail Valley Drire, Suite C-l . Vail, Co. 81657 . (970) 476-6342 . Fax: (970) 476-4901 June 17, 1996 George Ruther TOV Community Development Re: May Resifunce George, Thanlafor taking time to meetwith Bill Pierce and me on the above referenced project last week. Below are the responses to your questions and comments. AIso, attached is an update set of plans reflecting some changes per your requests. The items belaw correspond to those items in vour letter dotedJune 12.1996. @ I Please note the comments on sheet AI02 Site PIan pefinining to location of new utility lines. 2. The site will be laid out by a licensed surveyor, ond we ctre aware the outer-most face of the building will be placed outside of the required setback lines. 3. The crawlspaces have been noted as requested. I believe there are only two crawlspaces. 4. The requested section, as discussed during the meeting, will be looking to the west through the east garage. I'll provide you with this section prior to or at the DRB meeting on l(ednesday, June 19. 1996. @. n, barrel vault height has been lowered to el. 87'-0" per our discussion. Re: drawings. 6. As discussed, we will provide qll noted or appropriate details at the DRB meeting. 7. We hove contacted Nicholas Lampins to provide an update on the original hazard report on this property. We understand this update is required prior to isstance of the building permit. I'il copy you with the report once we receive it. bUY. There is not patio or deck outside of the doors in question. These doors simply oryn to a grqssv area adjacent to the golf course. If there qe any other questions or comments please call. Ihanks! @ @ Associate L:\95 I 5\DOC\TOV06 l1.DOC -"-{2bc)&,4 c.:tE: Lpg sa I -l \- \) oa FILECTPY 75 South Frontage Road VaiL Colorado 81657 970-479-2 I 3 8/479-2 I 39 FAX 970-479-24s2 June 20. 1996 De p artrnent of C ornmunity D evelopme nt Bill Pierce Fritzlen, Pierce & Briner P.O. Box 57 Vail, CO 81658 RE: The proposed May residence. located at 1067 Ptarmigan Road/Lot 4, and west half of Lot 5, Block 5, Vail Village 7th Filing. Dear Bill: Thank you for appearing before the Desi-m Review Board on Wednesday, June 19, 1996, with the proposed tvtay reiidence. As you are aware. the Design Review Board corditionally approved the proposed residence. The residence was approved rvith the following conditions: I (Or) fttat 5 ever-qJccn fees be plantcd on the north side of the rcsidence, adjacent to the golf cowseV andthat a rJviscd landscape plan be submitted reflecting those changes. A Geologic HazardReport must be prepared in accordance with Chapter 18.69 of the Town of Vail Muiicipal Code and submitted io the Community Development Department prior to the application for a building permit. A rer,ocable right-of-way permit must be issued for the improvcmcnts proposcd in the right-of- way prior to the issuance of a building permit. An outdoor lighting plan must be submittcd, reviewed and approved by the Design Review Board prior to the issuance of a building permit' Public Works approval is required prior to tbc issuance of a building permit. 3. 4. 5. Again, thank you for appearing before the Design Review Board with the proposed May residcnce. Each of the conditions oi approval indicated above must be resolved prior to issuance of a building permit. Should you have a-ny questions or concerns with regard to the information addressed in this ietter, as always, please do not hesitate in giving me a call. You can reach me most easlly at479-2145- GR/jr -Q,,a,r-.- {S rr"r"rroruo 75 South Fronnge Road VaiL Colorada 81657 970-479-21iV479-2139 FAX 970-479-2452 June 12, 1996 D epartment of Communiry D evelopment {< Dale Smith Friblen, Pierce & Briner P.O. Box 57 Vail, CO 81658 RE: The proposed May residencc, Lot 4 and west half of Lot 5, Block 5, Vail village 7th Filing. Dear Dale: Tbank you for your Design Review Board application for the proposed May residence to be locatdat 1OOZ ntardgai Road" Staff has iompleted a preliminary rwiew of yolr-application. Several issues were idJntified through oru review. Each of tbe issues addressed below must be resolved at the time of final review. Cunently, your application is scheduled for final review before the Design Review Board on Wednesday, June24,1996. The following is a list of issues which must be addressed: l. The utility lines serving the residence from the north are proposedlhrouglr an existing stand of aspen tees. Please relocate the utility lines so as not to disturb the existing stand oftrees. 2. As proposed, the structure is located right on the north, south and east setback lines' Please note that at the time of application for a building perrnit, the building foundation will be required to be located byi licensed surveyor. Additionilly, pr.tor to anyframing inspection for the proposed residence, atr Improvexlent Location Certificate will be required. 3. Label alt the crawlspace areas on the proposed floor plans as having a head height of5' or less, 4. Please provide section drawings through the east garage. A section should be provided througf the garage in both a north/south direction, as well as in an east/west direction. 5. In order to deterrnine building height, please provide ridge elevations for the proposed skylight and barretvaulL e7 o'tV {S"ot"uoruo dr 6. prior to final review, please provide drawings ofthe architectural details ofthe building' (i.e., soffit, fascia, deik rails, window and door trim, etc')' T.AccordingtotheTownofVailGeologicHazardAreaMaps,thelroposcdrgsiaencl]1 partially l6cated in a medium severityiockfall zone. Please pr91de a hazard repol!.tor the property, in acoordance with Chipter 18.69 of the Town of Vail Municipal Cddb. g. On the northeast comer of the building, on the north elevation, a row of doors is being proposed. Do these doors exit out on-to an exterior patio? If so, the patio has not been indicated on the site plan or landscape plan. Please make any corections necessary. . . Again, each of the issues addressed above, must be resolved prior-to-fin{ review by 1!9 P$iry Review Board on June 24, 1996. In ordei to remain on the agenda for the June 24, 1996 Design Review Board meeting, please submit all revisions by no later than 5:00 p.m., Monday, June l7th. Should you have any questions or concerns with regard to the information addressed in this letter, as always, ptiasl do not hesitate to givc me Jcall. I can be reached most easily during regular office hours at 479'2145. Sincerely, Htwn- George Ruther Town Planner Gr/jr - c/,*z7 r P/Y74 / n, 4/ubaV'r?Vov A'77'/n ' fr FamiIy Oj Primary/Secondary ZONE CHECK FOR Residence, Duplex, ZONE DISTRTCTS DATE: . LEGAIJ DESCRIPTION: L,ot l, {r?"n Subdivision ADDRESS: OWNER PHONE PHONEARCHITECT Single .,+,1zoNE Drsrnrcr #/S PRoPosED usg ?ls s Height TOEAl GRFA Primary GRFA Secondary GRF'A . Setbacks Site Coverage Landscaping e- LoT srzE ' ,gfr{ ' . 318F- BurrJDABrrE rJor AREA 41rp,.wed Er.+f;,Fins s{sng€cg TcFiI (30)[dt 77<tD + 42s- =J,ils 3j& 3jllt "z t,5r(O + 42s =.l %olc { sncr (300) (600) (s00)ffi t.*lI----_ Permitr,ed slope 8t proposed slope-alL _ 20, 15, 15, 3,3'^ 9 gaD 3'/6' 5 neqrd Complies with T'.O.V. LighLing ordinance Yes ol: No 33' 4JLtR+ot- Front, Sides Rear 7D% 14s zo'ts / 1O.€t<.s 7,931 tD.^//.2 ctL_.+- OL 2', Percent Slope l< > 3O%'t Zfu/o 3) Geologic Hazardsa) Snow Avalanche /tlo. Dt rr'OcJ(rarr -llteb <6.tElc) Debris FIow ND. - No/ 4) Yes wet lands view Corridor EncroachmenE: Does this reqiiesL iuyuive allqw muqh of Ehe alLowed 250 250 Addi t,ion? Np Addition is usofrifEfr-Efig reques g?_-e,_ .ttot t*r l0% Rebaining Wa11 Height.s , Parking Garage Credit Drive: WaLer Course Setback (30) (s0) Do Finish Grades Exceed 2:1 (50t) Envi ronmen taI /Hazards :1) Flopd P1ain b) Rockfall oY- < ,l rN,l* YEs_ No_4_ ou_ Previous condit.ions of approval (check properLy file) : olL oa er ASCilrlcrutl PlAr{}'ilN0 t N T r R t oR s DqlsEIC OB SCFRnITT'E - ww\ublf 2(.W,4W? NTa 4ale i, ..,:.,;d:,-.1-::i;,Sl... ...*, I --.- PrrAtAw "-?3Yt11P (re.$?Q a17. tANP ?lllaq-.' /n"1t-a ll,'/ t h"i"' l6t '"--#-/'' , agc i RGEE!.d BtvtSror o4z4 rlu-^ts i@:4 /l er ABCNlTtCruRt PIArrtH0 tH rr Rt 0Rs DslrJrIC 6Ur( 1$UC3rotJ AT Fv ?a\q42W, eW9 w?e@ A'el|1. wdrt ggw' .$ALLta ?^vWz ?_A.{U?-5 +ffir+: ?4P Wo-l b" an?.af?P e&:ft+ lrylAiisa t^t*t* @' 7FitYIJ),-^'( "\1 ,ni,4,'t) '22 qOf !*'t{rv r.rv-oQ -{o e! t 4']1"t-l- n>svtn,tri,.rc.Jo c< ) Q*, A> aepd,L &fuEr ,U)ulld fu./v.t'ru7r vwv4?eizoFila izt' av, gaag <- aFv. ?Ttt+d Nok -^u**fuI;; b' ins*tu'o ( - ue o+ fl+"u-it * 1glr"*3*a S*- IEYtrgIU 8. t!o. =-_-!.GF fl^ 4/ -.k1€m v (/ ='-.t ?gaUE oj ACCUlItcrunt PTAHX tNs tx Tr Rr oRs DEIIDIG OB SflrRnuLE sIDre Ott CZ,IV. vJ /\4Y "*9I.4tFt4 /r z-2xtz 2t 6i,&r-]t]6 llb ?A, ao,*\(Vfrt+t".a> iill Ith t= il{| l: ::"'/1 lllili yv {+f -l+" 4zrv iug'5.(*p er,z"'v-2 ----r-= O\ €-auz =ya4LaFo\ l><d *4, St?trJ,.qat ep*3 2-zxtzZt E4)AA 44.tu wn Hua Tuc, - - =-F4lff +ury1arg aq 1^b/,\ I I l_ llAY ft,ttlo*pe EEU!8IqU D8c. tlo.l8oiEe!. frit L few,ila 7t*F 4 ,"q\rft{ lol' '' .oaerceBrlner snFrRnuLE 4eefr,rrJr4w4ntltlll i: I ll lltltl -*ir-_r t---rt llrlli : I ,-.i I_-:_:: . --- ' -'--,l --t: roaL ft,+J/4- /ArtNat ear -1,<+ AT|ENQ4t{.qpa7vetN.4\tew. /Lner \--. ItOAr Ll PtE 4r\5==Wauaua\p. 4" cerreehvrl v1tA N z*p . Ewtv.o?FkttA 1Vr,,1t4r rtoalEc! $ vtr-.n*.o*i IM \6kM?tY6Jre E+,9t41-a74'1r,+T+t#FET. In EEYIASIf Ac. tK). qivtt@ i+(Ya'nw ^lL(bVf,)tj.Et tl|. v,c, vFtN. l! 1-XlI,-93 ?tvlavl4 -j OfFct lox 57 1000 lJotrsRDot g|gjffi,Sl6so 505 476 6542 FAx sos 476 4eo I oj -.--:-.gtt=3iiu' er ARCHITgCTUNE P.[AI{NIH€ IH I€RIQRS D8$rIISG OB SgrrRnIIrE A FrN FeV ^. - l/4 u^I|vtr, aA . 2x2 e.96?E.t<t dufr FU,T ar ATUTHAFIE oN 3plt ?a? ap 3t/ztl ?aL'( Ito . ttJ5 . aFy* rvLT arJ , >"iP ?".q8 ./att rue ----\ /2, 4Gerfb?\ ... ruw #TT ItJ5. i+Fftr l"-, :*a tai-v .' _-.Ta?. IJAr-L : 3trorlz ae 1Xb qet$A 42H 1/2't f AP.aA zxo A/ FUtv 6ATt b nt, - v. B- ,! / ?ttJ. ar',r, . alvIEI(u nnc. ro. .r1&Y-.- 1"tr2 ._. _ nge I RGSET.doc 1-!.lar-g3 i/ ,ii6io t-1 OFFICEEOXS? IO0OUSEID€!tW'VAtlCO.ORI\DoOl656 SOJ 476 6J42 FAx JoJ 476 4901 ojer lllllll0 lNTrRloRS SCrRnIrr.R aH r24 ttr* aF1t a^l1a)J6 otJ ZlxZ e.Eep*t aA P+ (e-LT 6N ef "4A1/^reQp g+r Fr)e oA 3t/ztl ?ovY 150. l|Jt aA 9* FerT Al Aa't'7A?- ?ee- ^'12 , '\---',. 4.L..fuiJ.4 o-? reue5 6ee- .T4)arurAL. ,i ,., 1Yz -4 1-o' 'i:$9 1 )RGSm.doc -l-Uar-93 Qt'..'iStolJ --'l Ancfi lTEcrun! pLAttxtNo rNrIRt oRs .:=cffisk- .N '.. ;'h-u ,.V*P'?'ri. Vq"xl'y',v2" fuc er+. .."fuvT-Ih?L : dd/\Ttt-*/' 1? ---..'i' :-. :.E-'.- - llu " 1'-o" aago I lRcs8'l!.doc : Lf-Uar-93 I8I[IAId DBG. rl0. Oa O1 FritzlenPierceBriner 1650 E. Vail Valley Drive, Suite C-I . Vail, Co. 81657 . (970) 47&6342 o Fat: (970) 4764901 June 19, 1996 George Ruther TO V C omrruni ty D eve I opment Re: Mry Residence George, Attached qre several details ( site railing, roofeaves, etc. ) per your request. I hove yet to develop (or findfrom the previous May residence) qny window and/or door elevation denils. These details will be ifuntical to those on the existing house, and I will prwide those to you as soon as I can. If this poses a problem please let me htow. Thanks! Dale Smith, Architect Associate 5- 1O't4 ettaz<ererJ ' L:\95 I 5\DOC\TOV06l9.DOC oj Nicholas Lampiris, Ph.D. coN$u-TrNri o!pLQGriir o'.t Jo?of,163u,".n 'holc / For (97O) g7F +00 E4 HOUFS) July 3, L9P6 Dale Snith Frt tzl rnPi rrcrBrl ner t65O E. VelI vallEy DrlvrEsite E-lVelI CO Elg57 RE: Hezrrd Eveluatlcnr 1067 Ptermigan Eoadl llry Rrridrnce Dear Flr. Smith: I viritrd thr aboye re{trenerd htrne tn Vail rrcrntly for purFotrlof r g€ologtc hessrd cv.elusticnt especi.l ly cr tt pcrtainr torock frll potrnttal , As you know thir hazrd l; noted on thoTown o# Val 1'g aFs e3 rncrorehing onto tho propartyt wtthtrltediumr' Cmlgnrtion. In edCttlonl debrtr flow end avalrnchrhaeard lrt nrpprd ar qxtcndlng to the gouth sldc of tlrs rord. The exprnrion, ei shonn on your mrps (htheri tha wcstirn hcme wtllb: rrrcdl r 1r on the north rtds sf Lhe rcad I ftlrthEr from thE Eourtrc ef rocki, end out of the othar tno zonag. The topogrephy ir such thet rockt wilt tcnd to rtop tn thr hrevy sbpEn grorth on the solrth 11 di o.f the rEad. Thr outcropplng Ofrocke ebovr the lot ig nlnor and quitr r dlrtrnct from thirhqure. I t.u no lsrgd rggFi ntf,r thtlr homG. EvBn tnougn lt lrnot llkrly thrt mrd pr snow cln resch thr proporcd rxpenrien, ltReuld bc prqcltnt tg lanulcapc and graCe the front (routh) ttrlE ofthe propcrty to preclude netrrtrl from .ppro.ching rrErr o+vulneraDlflty. In adclttttrn to tnt HrItE EhoHnr Ferhrpg th: cfitrydriva could hrvr r high Fotnt ln it et about thi proprrty lino toprevrnt ,nrtarlal from enterinq vEry fer. The nesr ride o{ thrhane (frontl rhoutd be plsnnEEl eccordlngly, Tha proprrty doee lia ln e groloEtcrlly frnlltlrrG rFetl butdrv:lopment, or Bltlgetish in front of tha hom:1 will notincrrrrl tha hrzrrd to othrr Frop:rty, or gtructuran, or topublic right3-o+-rayl roads, itraet;r €arcrnrrrts, utilitiar orfasillttes or other proparttrt of any kind. f{ thrrr are {urth:rquestlon3, pleem cmtact mt. Sing:arely t-jrLl -d/q Nteholff grlplrlr Eonrulting 6eclogist roo E gCUgId NS'IZIIE{I08t9Zt0tE rvd cz:IT s6/80/10 OO Design Review Action Form TOWN OF VAIL Project Name: May ResidenceChange to approved plans Project Description: Change to lighting, fencing, addition ofstone veneer Owner, Address and Phone:Roy & Paula May Architect/Contact, Address and Phone: Dale Smith, FriElen, Pierce and Briner, 1650 Pqst Vail Valtey Drive, F'allridge C-l Vail' Colorado 81657 Project Street Address: 1067 Ptarmigan Road Legal Description:Lot 4 & the west ll2 of Lot 5, Block 5' Vail Village 7th Parcel Number 210l-092-09-002 Comments: Building Name: Motion by: Ted Eingst Seconded by: Clark Brittian Vote: 3-0-1 @ierce abstain) Conditions: Town Planner: George Ruther Date: tlzt/gE Board / Staff Action Action: Approved F: TEYERYONE\DRB\APPROVAL\9 8\l DRBAPPR. FRM DRB Fee Pre-Paid: $20.00 Town ot Vall rtment of Communlty Developmenl 75 S. Frontage Road Vail, CO 81657 Name: DAl€ SvrniJJ.r Address: Project: lo the TOWN OF VAIL Account No. Please make checks payable 001 0000 314 1'110 001 0000 3141112 001 0000 3141112 001 0000 3141112 00f 0000 3141112 001 0000 3141112 001 0000 3141112 001 0000 3141211 Zonino and Address Uniform Buildinq Code Uniform Plumbino Code Uniform Mechanical Code Uniform Fire Code National Electrical Code Other Code Books Blue Prints/Mvlar Coov Fees 001 0000 314 111 1 001 0000 314 1 11 1 Studies, Master Plans. elc. 001 0000 315 3000 001 0000 311 2300 001 0000 315 2000 001 00003123000 Conlraclors License Fees 001 0000 312 4000 n Aoplication Fee 001 00003124000 Additional tion Fee 001 0000 31 1 2200 001 00003153000 D gql$ Ee ytey_Qgerdle _elP re - Buildino Investioalion Fee 001 0000 240 3300 sit 001 0000 312'^^^r'r --r-..-^^r I i^J!66a 001 0000 230: 'ooi oooo7or *lti,ffi'tg".Hiil; #.lilflrount Tendered ,Sdad pnY T0 Tt€ Q!!ER S FTRSTBffT( n unIL UAIL, Co 8165/ : l0?l0l5l9: F{N DEHFII {ILYTnf{ tF VAIL 57e e337 '001 0000 310 0000 311 001 0000 31 1 001 0000 311 001 0000 311 ooT0ooo gt i ooTooob s1T oo-r o0o-o s11 Tom of Uail ---- -!fr nFTffiR RECEIPT +lr sEJ! ESlrlI FB r)mtfR: ImTE: fttfrt9l ut nscriDir ieegzt 001 0000 311 0-01 0000 311 001 oooo 311 o0r 0000 311 DESCRIPTIfi{ O€SIfl NE|JIEII FErxtf $Illl ffY I ffiTf{I TP TI t5e.0e DR 0( Comments: tsY nfiERtm uil0 ffIfr-fifr1]1 16:,,147 fso.nMilI TFIDEEI} IsE:EI TSI{ YIIJ F(lR YITJR PNYEilI! Checkf l'lt{-l Received by'6.R .Cash -- Money Order # Penaltv Fees/Re-ln Plan Review Be-check Fee ($40/per ho Olf Hours Inspection Fees o O*rd cdl the Planning staff at 4?9-21 38 APPLICATION FOR PLANNING AND ENVIROI\MENTAL COMMISSION APPROVAL GENERAL INFORMATION fni*"pptiotion is for any poject requiring approval by the Plurning and Environmental Commission. For spcific information. se€ the submittal-r.quiti.*t" foi tne particutar approval that is requesbd. The application can not be accepted until all required information is submitted- The project may also need to be reviewed by the Town Council and/or the Desigt Rwiow Boud. A. TYPEOFAPPLICATION: tr Additional GRFA (250) tr BedandBrealfast tr Conditional Use Permit tr Majoror tr MinorSubdivision tr Rezoning tr SigrVariance tr Vriance fl ZonngCodeAmendment B.DESCRIPTION OF THE REQI.JEST: tr Amendment to an Approved Dwelopme'nt Plan tr Employee Housing Unit (IYPo: tr Major c tr Minor CCI Exterior Alteration (Vail Village) tr Maju or tr Minor CCII Extctior Alttration (Lionshead) tr Special DweloPment Distict tr Major m E Minor Arnendmqrt to an SDD ft.6ffi 'zw,fu,{w ICIy/N0FVUl" c.LOCATION OF PROPOSAL : LOT'/' OWNER(S) STGNATIJRE(S): NAME OF REPRESENTATIVE: MAILINGADDRESS: K_t FILING y'ATZ U, D. E. F. G, NAMEoF ovtNexlsl: P.dq l' Pzlrua r/1al/. MATLTN6ADDRESS: / z, '. ,xtr 9r. crJlar -72 (l0t/O' p'oNre, " i{r ?-."/ ,:? PH)NE. 1/6 f( b.4/L FEE - SEE THE SUBMITTAL REQUIREMENTS FOR THE APPROPRIATE FEE. ST'BMIT THIS APPLIC,A,TION, ALL SIJBMITTAL REQI'IREMENTS AND TIIE TEE TO TIIE DEPARTMENT OF COMMTJMTY DEVELOPMENT. T5 SOUTH FRONTAGE ROAD' For OfficeUse Only: rceraa: L9o/ cw,1b69 sy: A'k Application Date:- PEC Meeting Datc VAIL, COLORADO t1657. Rcvincd 6D5 /ot Design Review Action Form TOWNOFVAIL Project Name: May Residence Project Description: Change to previously approved plans-conversion of crawl space on lowest level Owner, Address and Phone: Roy & Paula May Architect/contact, Address and phone: BffiTlll;,X;:"J:l;$ililtf;T,llil'r1l??""st vail vailev Project Street Address: 1067 Ptarmigan Road Legal Description: Lot 4/East ll2 of Lot 5' Block 5' Vail Village Seventh. Parcel Number: Buildine Name: Comments: Board / StaffAcdu Motion by: Action: Approved Seconded by: Vote: Conditions: Approved per plans attached and dated 12124/97 Town Planner: George Ruther Date: 12/24/97 DRB Fee Pre-Paid: S50.00 F:\EvERYoNE\DRB\APPROVAL971MAY. D24 23 December 1997 George Ruther Town of Vail Community Development Re; MAY RESIDENCE 1067 Ptarmigan Road Interior Conversion Addition Submiffal ARCHITECTS George, Attached is a partial floor plan of the area we discussed yesterday. This area, below the west garage, was originally intended to remain crawl space. However, there was apparently some confusion between myself and the contractor at the time other crawl spaces were converted to allowable GRFA this past August. This submittal is intended to legitimizeilegalize the area indicated on the attached drawing, which should be eligible for usable space per the Interior Conversion Ordinance. I will be submitting to you this Monday, Dec.29, the Exterior Lighting Alteration plans we also spoke of. Previous submittals; Original DRB approval - June 20,1996. Previous Minor Alterations approval - Apil21,1997 Previous Minor Alterations approval - August 26, 1997 A. Sheet A201 - Lower Level Floor Plan (partial attached) 1. Revise clouded area between grid lines A & B and 7 &9 from Crawl Space to Unfinished Basement space. Should you have any questions please call. Thanks and have a great holiday! &U-c7r4- Dale Smith Architect L\95 I s\DOC\tvl 22397.wDd PlanningaArchitectureolnteriors 1650EastVail Valley Drive Fallridge C-l . Vail,CO81657 . fpb@colorado.net . Iax (9701476-4901 . (97O) 476-6142 Qu.r,ionr?Qlll thc Plr:n:iirg StatTat 479-1128 APPLICATION FOR DESIGN REVIEW APPROVAL GENEML INFORMATION This application is for any projcct rcquiring Dasign Rcvicrv approval. Any projcct rcquiring dcsigr revicw must rcccivc Dcsign Review approval prior to submitting for a building pcrmit. For specific information, sce the submittal rcquircmcnts for thc particular approval that is rcquestcd. Thc application cannot bc acceptcd until all the requircd information is submittcd. Thc projcct may also nccd to be rcvicwcd by thc Town Council and/or thc Planning and Environmcntal Contmission. Dcsign Rcvierv Board approval cxpircs onc ycar after final approval unlcss a building pcrmit is issued and construction is startcd. A. DESCRIPTION OF THE REQUEST: LOCATION OF PROPOSAL:B, c. D. E. PFTYSICAL ADDRESS: PARCEL #: ZONING: NAME OF OWNER(S): MAILING ADDRESS: (Contact Eaglc Co. Asscssors Officc at 970-32E-8640 for parcel #) PHONE: F. G. owNER(S) STGNATURE(S): NAME OF APPLICANT: tr New Construction - $200 EJ Addition - $50 E Minor Altcration - S20 H. oNE: q7d /71- tst'Z Construction of a new building. Includcs any addition whcrc squarc footagc is addcd to any rcsidential or comncrcial building. Includcs minor changes to buildings and site improvcments, such as, rcroofing. painting. window additions. landscaping. fcnccs and retaining walls. etc. DRB fces are to be paid at the timc of zubmittal. Latcr. whcn applying for a building pennit. pleasc identiff thc accuratc valuation ofthc projcct. Thc Town ofVail will adjust thc fce according to thc projcct valuation. PLEASE SUBMIT THIS APPLICATION., ALL SUBMITTAL REQUIREMENTS AND THE FEE TO THE DEPARTMENT OF COMMUNITY DEVELOPMENT. TS SOUTH FRONTAGE ROAD, vArL. coLoRADO 81657. MAILING ADDRESS: @J jYel. ao'o' HOSE BIB--I TlECHANICAL VENTILATION TIJILL BE NEEDED FOR BOTH CRAU,IL SPACE AREAS. ACCESS PANEL o (q UNFINISHED BASEIlENT LINE OF GARAGE ABOVE RE: A2O2 # Eso IO' CHU TIJALL IIJ,/ FTR. T.O.CONC EL. 51',-O" leorLee rLur loPENrNG.tcooRD. u'l IIIECH. CONTRACTOR 1 I1ECHANICAL NEUJ GRFA 3I5 5F SLOPE CONC, SLAB TO DRAIN TYP, t2'-to' T.O. IIIALL 2XlFRAHEDI,IIALL I' PL ST //€r/4 Pt*t AZa/ LoA&, LE\,/EC F6oqZ fUSlA/d%Fftb,arug Z3 ./ob7 PfuVn/ra^/rec 4/ 3 October 1997 Town of Vail Community Development Planning & Environmental Committee Re; TOV Outdoor Lighting Ordinance Amendment ARCH ITECTS The purpose of this submittal is to review the existing TOV Lighting Ordinance and it's possible alteration. I would like to review three things; it's stated intent, i.e. why it was created; the existing Ordinance in terms of it's specific requirements; and difficulties that are arising with it. With this in mind, I would then like to review potential amendment(s) to the Ordinance. As stated in the Ordinance, it's intent is ".../o minimize the unintended and undesirable side ffict ofoutdoor lighting, while encouraging the intended and desirable safety and aesthetic purposes of outdoor lighting..." artd"...to protect the legitimate privacy of neighboringresidents...".This concept is still valid and conect. However many of the specific requirements generated to implement this concept are no longer valid. The Ordinance, as it is cunently written, uses the area of a given site to determine the quantity of "light sources" allowed for that site ( a light source being defined as "a single artificial point source of luminescence...". One light source is permitted for each one lhousand square feet of site area. Other definitions noted in the Ordinance include; Luminous Area - the maximum light emitting from a single source (the physical area of source measured in square inches). Source Lumens - total initial lamp lumens of the light source. Height Limits - maximum mounting height for residential applications is eight feet (8'). Luminance - a ratio of source lumens to luminous area. Exemptions - current residential exemptions include Christmas tree lights, and [address] sign illumination. These requirements were based on the lighting technology and desired aesthetic effects available at the time the Ordinance was written. These requirements no longer fully accomplish the goals for which they were intended. With the existing codes, it is possible to meet all requirements, yet still create undesirable side effects. New technology which uses both smaller light sources and lower luminous output are discouraged with the existing wording of the code due to the quantity restriction. The current Ordinance provides no means for the Town or Design Review Board to make any subjective exceptions to accommodate new technology and design concepts. L195 1 5\DOC\LITEAMEN.WPD PlanningoArchitectureolnteriors 1650 East Vail Valley Drive Fallridge C-1 . Vail, CO 81657 r fpb@colorado.net r fax (970) 476-490'l . (97O') 4764342 lO/23/57 lL:'L7 FAI 970{764901 Below are two proposed exemptions to the oristing Lighting Ordinancc, which allow the Torvn md Design Rwiew Board the oppornrnity to addrcss design pmposals on an individual basis. These o<emptions do not alter or undermine the qdsting Ordinance in any way, but povidc a means for that Ordinance to mect its intended goals; "...to minimize the unintended and tndesirable side efect of outdoor lighting, while encowagingthe intended and dcstrable safety and aesthetic pwoses of outdoor lighting.,." and'...to protect tlw legitimate privacy of neighb or ing residents..." . PROPOSED EXEMPTION Additionrl LiChting Light sources requested beyond thosc altowcd by Section 18.54.050(C)l 1, Item b' Frequency .qhnll meet the following; Light Sornces, whioh are placed uo more thm 18" above finished grade, meeting existing Sections 18.04.137 pul-Cutoffor 18.54.050 Luminase, may be gfante4 for safery and/or aesthstic purlx)ses, atthe discretion of the Directory of Comnunity Developm.enL FRITZLEN PIERCE L:\95I5U)Cu,rIAM[NzWrr, PlanningaArchit€cilreelntetiors 1650 Eastvatl valley Dfve Fallridge c-1 ' vail' co 81657 r hb@colorado'net ' fa" (97o) 476-4901 t {97o) '7ff342 @ool MEMORANDUM To: Planning Division From: George Ruther, Town Planner Date: September 23, 1997 Re: Exterior Lighting Discussion with the Design Review Board On Wednesday, September 17, 1997, the Design Review Board discussed the Town's exterior lighting ordinance. The discussion was in response to a request of a local architectural firm to use new technologies in outdoor lighting such as fiber optics. The following is a summary of the DRB's comments on the issue: o The current ordinance that regulates lighting based on lot size does not necessarily address the problems associated with outdoor lighting. o The idea of allowing low-level ground lighting seems reasonable. o Amend the ordinance to regulate a maximum luminous output for a site and but less emphasis on the numbers of lights. o Do not further complicate the existing ordinance if we make changes. o Create exemptions for certain types (exit lights, step lights, etc.) or levels (less than "X" luminous output, fully cut-off, etc.) of lighting when it comes to quanttty' o Continue to ensure no negative impacts on adjoining properties. o Establish development standards (orientation, height, location" etc.) for outdoor lighting and relax the current regulations. o The Town should amend regulafions to keep pace with new technologies. e Consider a foot candle measurement for the development as a whole. Again, the above thoughts are the result of the DRB discussion on the outdoor lighting issue. I would suggest that we discuss the issue at greater length and possibly make changes to the existing ordinance. In my opinion, however, this is not necessarily a top priority given the current staffing situation. TO: FROM: DATE: RE: o MEMORANDUM Planning and Environmental Commission Community Development Department October 27,1997 A request for an amendment to Section 18.54.050(J) (Design Guidelines - Outdoor Lighting) of the Zoning Code to exempt light sources which are no more than 18 inches above grade and are either fully cutotf or have a maximum initial lumen output of 250, from the total allowable number of exterior light sources permitted on a property. Applicant: Roy and Paula May, represented by Fritzlen, Pierce, BrinerPlanner: Lauren Waterton I. DESCRIPTION OF THE REOUEST The applicant is requesting an amendment to the Zoning Code to allow additional exterior light sources beyond the total allowable number of exterior light sources permitted on a property. The additional light sources are proposed to be no more than 18 inches above grade and are either fully cutoff or have a maximum lumen ouFut of 250 (the equivalent ot a25 watt bulb). The proposed code revision would amend Section 18.54.050(J)2b (Design Guidelines - Outdoor Lighting - Frequency). The existing text is shown for reference, the proposed additional text is shown in itallcs. b. Frequency. For lots in residential zone districts, the maximum number of light sources per lot shall be limited to one light source per one thousand square feet of lot area. The location of said lights shall be left open to the discretion of the property owner, so long as the lights are in compliance with the Town ot Vail's Municipal Code. Lights sources, which are placed no more than 18" above finished grade, and are either fully cutoff, as defined by Section 18.04.137, or have a maximum initial lumen output of 250 (equvilent to a 25 watt bulb), may be allowed in addition to the total number of permitted outdoor light sources. Number, location and style of such light sources is subject to Design Review. The proposed text change would allow lights such as, step lights, landscape lights and walkway lighting, in addition to the lights currently permitted. These lights are generally recessed into walls or mounted just above ground level and provide lighting for a small area. The applicant has indicated that because the current regulations limit the total number of lights per site, there is a tendency to use one brighter light than to use smaller more focused lights. The result is a greater impact on adjacent properties from these brighter lights, The applicant has stated that the proposed change meets the intent of the lighting regulations which is to minimuze the unintended and undesirable effects of outdoor lighting. II. BACKGROUND In 1993, the Design Guidelines were amended to add the outdoor lighting regulations. The current regulations for residential properties limit the maximum number of light fixtures to one light source per 1,000 square feet ol lot area. For example, a 15,000 square foot lot is permitted a maximum of 15 exterior light sources. There are also resrictions on the total luminance of each fixture and the maximum height. The only light sources which are currently exempt from these regulations include Christmas tree lights, sign illumination and municipal lighting. See attached for the complete regulations for outdoor lighting. III. CONFORMITV WITH THE TOWN'S RELEVANT PLANNING DOCUMENTS In considering the proposed amendment to the Zoning Code, staff reviewed the intent of the Design Guidelines and the purpose statement of the Outdoor Lighting. Zoning Code According to the purpose statement of the Design Review chapter, the intent of the design guidelines is to ensure that development is compatible with the existing landscape and to protect neighboring properties from negative impacts of development. The intent of the Outdoor Lighting section of the Design Review chapter is to "minimize the unintended and undesirable effects of outdoor lighting while encouraging the intended and desirable safety and aesthetic purposes of outdoor lighting." Staff believes that the proposed amendment is in accordance with both the purpose statements of the Design Review chapter and of the Outdoor Lighting section of the Design Review chapter. The ability to add additional low level lighting may reduce impacts on adjacent properties. Property owners would have the ability to use these low level lights which have limited impacts on adjacent properties, while improving safety, particularly around steps and wallflvays. Staff believes that this proposed amendment will not negatively impact adjacent properties and can improve the overall aesthetics of outdoor lighting. IV. STAFF RECOMMENDATION Staff recommends approval ol the proposed amendments to the Zoning Code, subject to the following finding: That the proposed amendment is in accordance with the purpose statements of the Design Review Chapter of the Vail Municipal Code and is in accordance with the intent of the Outdoor Lighting regulations of the Design Guidelines. oo Design Review Action Form TOWN OFVAIL Projcct Name: May Residence - Changes to Approved Plans Project Description: See Letter in the File datd9l4l97 Owner, Address and Phone: Roy & Paula May 2l E. Scott Street, Chicago, Il. 60610 Architect/Contact. Address and Phonc: Dale Smith, FPB, 1650 E. Vail Valley Drive, Vril' Colorado' 8r6s7 476-6342 Projcct Strcet Address: 1067 Ptarmigan Road Legal Description: Parcel Number: Comments: Lot 4ll2 & 5, Block 5, Vail Village 7th Building Name: Motion by: Seconded by: Vote: Condition-s: Action: Town Planner: George Ruther Date: 914197 $70.00 / StaffAction DRB Fee Prc-Paid: Qucstions? C.tttPtunning Staff at 479'2128 APPI,ICATION }'OR DESIGN REVIEW APPROVAL CENIIRAL INFORMATION This application is for any projcct rcquiring Dcsign Rcvicw approval. Any projcct rcquiring dcsign rcvicrv mu'st rcccivc Dcsign Rcvicw approval prior to subntitting lbr a ttriiding pcrnrit. ior spccific infomration' scc thc submittal rcquircnrcnts for thc parlicular approval thal is rcqrtcstctl. Ttrc aplpiication cannot bc aoccptcd until all thc rcquircd infornration is subnrittctl. Thc piojcct nray also nccd to bc rcvicwld by thc Town Council atrd/or thc Planning and Environrncntal Cornnrission. Dcsign Rcvicrv Board approval cxpircs onc ycar aftcr linal approval unlcss a buil<ling pcrmit is issucd and construction is started' A. DESCRIPTION OF Tl.IE REQUEST: TOWN OF VAIL B. c. D. ti. I.OCATION OF PROPOSAI-: LOT: PHYSICAI- ADDRESS: PARCEL II: ZONING: NAMI] OF OWNER(S): MAILINCi ADDRTJSS: I]LOCK:FILINC: (Contact Eaglc Co. ,4U PI{ONE: Consinrction of a ncw building. Includcs any addition whcrc squarc tbotagc is addcd to any rqsidcntial or cornnrcrciill building. lncludcs Ininor changcs to buildings and sitc improvcntcnts, such as' rcrooling, painting. windorv additions, landscaping. fcnccs and rctaining walls, ctc. F. c. owNuR(s) SIGNATURB(S) : NAME OF APPLICANI': MAILINC ADDRIJSS: PE OF REVIEW AND FIIE: Ncw Conslruction - $200 TYPE OF RIlVlliw A E Ncw Conslruction !'looitiou - Q fr'linor Altcration - I t. @ @ DRBfccsarctobcpaidatthctinrcofsubnrittal. Latcr.whcnapplyingforabuildingpcntrit,plcascidcntify thc accuratc valuation of thc projcct. ThcT'own of Vail will adjust thc fcc according to thc projcct valuation. PLEASE SUBMIT THIS APPLICATION, AI,I., SUBMITTAL REQUIREMENTS AND THE FEE TO THE DEPARTMENT OF COMMUNITY DEVELOPMENT, T5 SOUTH FRONTAGE ROAD' vArL, COLORADO 81657. Asscssom Officc at 970-328-8640 for parcel #) PI-IONI]: MAYRESIDENCE 1067 Ptarmigan Road. Town of Vail Minor Alteration to Approved Plans Alteration List Previous submittals; Original DRB approval - June 20, 1996. Previous Minor Alterations approval - April2l , 1997 A. Sheet Al02 - Site PlanI l. Rerrise driveway slope and drainage pattern. | 2. Revise southwest edge ofpool deck configuration. I 3. Revise existing pool and deck configruation; APPROVED BY THE TC\AJN OF VAIL DESIGi'I REVIEW BOARD r .l_-* 4i4lq'| PIANNER 6@4GE ?' ' a. Existing deck and fence, west of existing pool, to remain. Existing pool to be filled and paved to match existing. b. Add raised firepit (re;detail C/AI02) adjacent to southwest comer of existing house. c. Add two stepped planter area at south end ofdeck stairs. d. Revise deck stair cofigtration. e. Existing curved wall around existing spa to remain. g. Add landscaped planter around exisfing curved spa wall. B. Sheet L101 - Landscaping Plan la. Existing deck and fence, west of existing pool, to remain. Delete previously proposed landscaping.I b. Add two stepped planter area at south end of deck stairs. Re;plan for planting materials. I c. Add landscaped planter around existing curved spa wall. Annuals planting materials to be placed here each season. C. Sheet A201 - Level One Floor Plan l. Convertcrawlspace into Wine Room ( ll8 square feet) per section 18.71.040 Interior Conversions. D. Sheet A203 - Level Three Floor Plan l. Add new floor structure at elevation 92'-0" (601 square feet) per section 18.71.040 Interior Conversions. Lt95 I 5\DOC\TOV82697.WPD PlanningoArchitectureolnteriors 165O East VailValley Drive Fallridge C-1 o Vail, CO 81657 r fpb@colorado.n et . fr( (97o, 476-4901 . (97O) 476-6?42 MAYRESIDENCE 1067 Ptarmigan Road. Town of Vail Minor Alteration to Approvcd Plans Alterntion List Previous subrnittals; Original DRB approval - June 20,1996. Previous Minor Alterations approval - Aptil21 , 1997 A. Shcct Al02 - Site PlanI l. Itcvise clriveway slopc and clrainago patternr l_195 r 5\DOCII OV82697.WPD l)lannirrg 1650 tast Vail Valley Drive F.rllridgc (i- I r SCHITECI5 ,4,,/ '', : ,,' .t-'.i* t c)K, -- r-tiictis*offiwcstT@c oipooi?cA[ conlig-rfaiio1 t 3. Ilcvisc cxisting pool antl dcck cort ligtrration; a. llxisting clcck and {bncc, wcst ol'cxisting pool, kl rcrrrain. llxisting pool to bc flllctl and pavcd to rt'tirtch cxisting. b. Add raisccl lilcpit (rc;dctail C/A102) acljaccnt to southwcst cornct' ol'cxisting ltotrsc. c. Aclcl two stcppcd plantcr arca at sotttlt cnd ol'dcck stairs. d. ltcvisc dcck stair coligulation. c. l')xisting curvccl 'uvallarouttcl cxisting spa [o rctrrain. g. Add lanclscapcd plarrtcr arottncl cxisting curvccl spa wall' l|. Shcct Ll0l - Landsc:rping Plan e a. Iixisting clcck and l'cnce, wcst of cxisting pool, to rcnrain. Deletc prcviously proposed lartdscaping. I b. Add two stcpped plantcr arca at south end of dcck stairs. Re;plan fiol planting matcrials. 1 c. Add landscapcd planter arouncl existing ourvccl spa wall. Annuals planting materials to bc olaccd herc each scason. C. Shcet A20l - Level Onc l'loor Plan l. Convelt crawlspace into Wine l{oonr ( | l8 squarc fcct) per sectiotr 18.71.040 Interior Conversions. D. Shcet A203 - Level I'hrco Floor Plan 1. Add new floor stlr-rcture at clevation 92'-0" (601 square feet) per section 18.71.040 Intcrior Convet'siorts. o Ar<'lritcctrrrc o Interiors Vail, CO u1057 r fpb@colorado.nct r fax (970) 476-4901 ' (97o' 476'6342 ,,---- _ - -'a- E. Sheet E101 - Electrical / Lighting Site PIan (Notes; A. re;Sheet Al02 for Site Plan alterations. B. Re; previously approved sheet A202 for building light). l. Add duplex outlets at various tree locations for Christrnas tcSrTECtS lighting. 2. Add recessed louvered step lights (X-2a) at driaveway wall. 3. Add recessed address light at driveway wall, to match existing house. 4. Revised patio stair step lights from louvered type to continuous fiber-optic rope-type (X-3), to be place under stair nosing. 5. Add paver lights (X-4) randomly tluoughout paver deck area. 6. Add low pedestal down lights (X-2a) at landscape area southwest and northeast of swimming pool. t.:Y)5 | 5\DoC1TOV82697. wPD PlarrnirrgaArchilccturcolntcriors 1650 EastVailValley Drive Fallrid6c C-l o Vail, COlJ1657 r fpb@colorado.net . fax (g7)r 476-4901 t @7o|, 476-6342. t, t' ,+- ,1:.i;.i::-+::::: . : : -,-, .----:- -- - ' 5 I Ftbr c0P TOWN OF VAIL Depanment of Community Development 75 South Frontage Road Vail, Colorado 81657 970-479-2138 FAX 970-479-2452 September 24,1997 Dale Smith FriElen, Pierce, Brincr 1650 East Vail Valley Drivc, Fallridgc C-l Vail, Colorado 81657 Rc: Exterior lighting at thc May rcsidcncc/Lot 4, Block 5., Vail Village 7th Dear Dalc, I reccivcd your fax of Scptcnrbcr 23, 1997. rcgarding thc cxtcrior liglrting at the May rcsidencc. On Wedncsday, September 17, thc Design Re vicw Board discusscd the usc of fibcr optics for outdoor lighting. The Board did qa! rcvicw thc proposcd lighting plan for thc May rcsidcncc, nor was that thc purpose of the discussion. The purpose of thc discussion was to get thc Board's opinion on thc cxisting lighting ordinancc and the usc of fibcr optics for outdoor lighting. From the discussion, thc Board suggested that your firm prcscnt a zoning code tcxt amcndmcnt to the Planning and Environmcntal Commission. Thc extcrior lighting approvcd for thc May rcsidcnce appcars on the DRB approved plans datcd Junc 16, 1996. Bascd upon thc lot sizcs, thc codc pcrmits you to install up to scvcntccn cxtcrior lights at the May residcncc. If you have any questions, please do not hesitatc to contact mc. You can reach me at479-2145. Sincerely, A*Q*-*l'-t Ceorge Ruther, AICP Town Planner {g*t^""' l0/29/Sl l$:S0 FIS70 0014781o F'ax Drtc: To: Fer: Re: thndcr: Cover Sheet October 29, 1997 George Ruther 479-2452 LiChting Orclinance Stcphanic Lord FRITZLESI PIERCB Eoor RCHITECTS please catl (nq47G6342 Ext 15. Creorge - I was askcd after the meeting to for over tbe lrrnen output of an incandcsccst 40W A lup. Atachcd is Osran Sylvania's and GE's specificatiou fo1 6 {Q$ InmF. Because the lurncn ortrput ranges with both rnanrtfirtrrt!f,'s, I would rccoumend thc highcst numbsr whic]r is thc standard GE bulb with 505 lumens be ihe maximum lumcn output to use in the code revision- Please call with auy qrrcstiors.4x/ Plannlng a Arf,hitcrl te a lnEriors 16sO €-t\hilvolLy Dric FalLidge C-l o Vril, CO 81657 o fptndrt@nil.ne! . frx (97o),+7g9ot . Om) {7e43,02 FRITZI,EN PIERCE Goor PAGE,66I/gv,L,o ,=rl"o=", ;r!tn'tl-ll rI E I I l0/29/gf lt:tg OCT zs 'sl? t 4: 34 F r 070{70{001 r*on l"trNc crGEHcy e) 5 E l-JrE' r|H ^TJEE!e7 E /\ Hg EH U ry ItIoatL IT -r--'-.-rt--G.-r----r-rrtt- - r.F- F-.:f-J.-Far-fr-r f t-xE-.EaH t| tf l!a:!,trF b.arh- t_it {.:r. TOTRL PBGE. AA I ** Ifrl-,rr Lol29/97 13:28 IXIRX N0-0s49 P.001 oo 'rowN ot; vAll, ,, ^r,- 3-_L -2i...-, -. .9a. ll:CXS NAltli t^ Y,\llt.E TO ()tj I A . .'- TAX''' - COST 'I (tf^l, Hiscel laneous Cash tJ'-l-:.i,tj":+ i f .i: *il : r,t - lt*r+ r r, t. + iI i f,!4 H':,:qrt. rrrt. # i.t # ,r::'ii.:; - FF:ITiL-Et.].FLEF:{::E,F,rF;It..1EFl'. irjf.{It,{ii t-|-:rt.:'t fif'IE.f.{{t f'1Ef.r1!i- firrr,:r-rrrt. t.en,:le r*d l :r:5r_l, t:ii:i Item paid rJ l ElB lJr:i 4 1 I lrjt:lrjr:l ffnoun l. paid :5r'1. r.18 i.1 : I t::il:t rNtt.1 | (Xt(,0 45t |lr l't(t 0'i'il'tlir------- I'1,; .TNDI.ITO_NAI_LBTTI cAsll l---J cK,I --'/-' lll.oLJ o 2 ( 98 L+ i,,a^/-,"d-il\ Grape Vine Filigreeo Hummingbird Filigreeo EP-7AtV0-BZ Evergreen 7" Post Mount fixture with standard classic Arch Overtay,o white opatescent art gtass and bronze finish. Post Mounts ESP.TAGW Evergreen 7" Low Vottage Stem Mount with classic Arch Overlay,o gold white iridescent gtass and verdigris patina finish. 5t€m Mount-Low Voltage Pine Needte Fi li gre eo Sycamore Fi[igreeo FixtureModet Height 0veralt MaximumHeight Wattage E5P.7 E5P.9 7 ,1' 9 3/r," 19 V?" (1)12V-50W' 27l/t', (1)12V-50W.FixtureModel Height overall l.taximumHeight Wattage ' l?V.s1lv type Al9 lonp .equned. Fixtures nount ,ith 1" squor. X l1-1/8 tten.EP.i EP.9 EP -T2 tr-10 7 1/1" 9 ,a" 72' 72 ,1" 15" (1) 100 (1)1oo (1) 100 70 14" (1)60 15 V{' 19 Vz" fi ues nount rith o 1 1.0. post odapter C-U.1. listed lot wet locationt. ,itlurct con be nodiJied lot lJw conpa.t fruoq.eot :[6" fn lvtat|* C,u*o€f, v i Downlight Bollard The clossic wedge fixlure is now ovoil- oble wilh o choice of oosls os o com- plete bollord fixture. The wood post provides simple inslollotion by direcf buriol ond mointenonce{ree finishes. The sleel posl mounls with conventionol base plote. See Seclion D - 682 - for o more complele descriplion of lhe fixture heod. Le* t|^u" llt' rin lt\rr'qhJ- oxld IE* lrrra^- a- zb l.w&'rt sN*Pw-L o eXample* o€ trJ0uld *,ael! bfnendrurtt. I eyl'evtor $hfu -ftta+ wtn rw propxed lNall rrDur^{ed, lu/vu/ - out*gl,,r* ltplz fW,^., I-Eo tlW t1v'o-w l6tr ahow a{T'd/- htoll rysufrl"l, €,^llt4 U^.+off , \rmq ft'ai-lgt\ - ,-'oGign Review Action Ftn TOWN OF VAIL caresory numoer t lZ oa" t/Z/ft Project Name: Building nane: -zt J*l Qe'-, .I Project Description: Owner, Address and Phone: nrcrrite"lglft ?)ddress and Ph one : L.egaf Descriptiontw4 lz/{abck 5 suoaivision \*;l Vi(l*,?a 1% zon€ District 7/^ Project Strset Address: Comments: Motion by: Seconded by: fl Approval n Disapproval y{ starnRRrovat Conditions: Town Planner It oate: 1f 7 I f 1l DRB Fee Pre-paid lt April 18,1997 George Ruther Town of Vail Community Development Re; May Residence 1067 Ptarmigan Road Vail,81657 George, ARcHlrEcr Attached it the DRB application, check (in the amount of $20.00) and associated drawings for minor alterations to the May Residence, which is currently under construction. Also atiached is a copy ofthe original zone district application. I've only included those plans that I felt were important to you; the site plan, floor plans and exterior elevations. While several clouds, indicating changes, exist on the bluelines themselves, I've clouded in red those changes that are pertinant here. Below I've described the changes that have occurred on each sheet. should vou have anv questions please call' Thanks! fu/t . A000 - Cover Sheet 1. Indicates plans attached for this submittal. Al02 - Site Plan l. Add manicured putting green and sand trap to northwest corner of site. 2. Add recessed natural gas fire pit between new building and swimming pool. 3. Add additional landscaping strip between existing spa and swimming pool. 4. Add above-grade natural gas fire pit and stone bar at south-east corner ofdeck. A20l - Level One Floor Plan l. Revise floor layout, including GRFA and crawlspace alterations, between grid lines 6/8 and A/E. l202-Level Two Floor Plan l. No TOV impact changes. A203 - Level Three Floor Plan l. No TOV impact changes. 1J04 - Roof Plan 1. No TOV impact changes. A30l - East Exterior Elevation l. Add window between grids I and 2. 2. Add stone adjacent to grid 1. A302 - South Exterior Elevations. l. Alter glazed doors between grids G and J. A.303 and A304 1. Add stone veneer as indicated. Ll95 I S\DOC\TOV4 I 8.wnd PlanningoArchitectureolnteriors 1650 EastVail Valfey Drive Fallridge C-l . Vail,CO81657 . fpbarcht@vail.net . fax (9701476-4901 . (97O) 47G,6342 L. r.vlred t,/l'l/9,! DESTGN REVISW o BOARD o OF VAIIJAPPLICATION - TOWN DATE RECETVED: DATE OF DRB MEETING: ***!rtt!t*** , coLo&ADO *lt*****!t**I. PRO.IECT rNFOR!4ATrON: DESCRIPTION: B.TYPE OF REVIEW: New Construction. (g200.00) _KMinor Alterat.ion ($20.00)Addition ($50.00) Conceptuat Review (S0) ? D, ADDRESS: , LEGAL, DESCRIPT ON: IJOtSubdivision Block 5 a meets and bounds on a separate sheet, If property is described bydescription, pleiase provideto Lhis application. 1ega1 and aLLach F. ZONING: NA}4E OFMailirig APPLTCANT: Address: NAME OF APPLICANT' S REPRESE}TT t{NAME OF OITINER (S ) : Mailing Address: I Mailing Address: J APPLrcATroNs wrIJL NoT BE pRocEssED wrrilour owNER,s sTGNATttRE L Condominium Approval if applicable. ,J. DRB FEE: DRB fees, as shown above,\ are Eo be paid at, EheLime of submit.ral of the DRB applilapion. Later, whenapprying for a buirding permit,-prbabe identify the accuratevaluat.ion of Lhe pqoposal . The iown of vaiL witt adjust Lhefee according to tiie cable below, E.o ensure the correct feeis paid. FEE SCHEDULE: VALUATION ,ralAarP v P rv,utru$ 10,001 - $ s0,000$ 50, 001 - $ 1s0, 000 $1s0, 001 $ s00, 000 $500, 001 - 91, 000, 000$ Over $1, 000, 000 DESTGN REVIEW BOARD APPROVAIJ,EXPIRES APPROVAI, IJNI,ESS A BUIIJDING PERI'{IT IsIS STARTED. r. .Ei ll $ 20.00 $ 50.00 $100.00 $200.00 $400.00 $s00.00 ONE YEAR AFTER FINAIJ ISSUED AND CONSTRUCTION JAN- ' Ei-9:2 -DEt,-DEPT- :!l\ :. ! ': '. -.t!rar"i ):i: ttr-g'rfu. ZOTTE D:ISTRIC? PROPOSED trSS Height. fotal GRE.A Primarfr GRFA Secoadarl, eRFA - sehbacks giLe Coverage .I,and,scaping & d< 3J6b ws 76'0€ / 4.€ Ig.-€ 7,951 t4f7?=z PFopoFeg TqFtt cZ- -- Yes &- _ No Nlr- 4 clL zD7, ce*s- 6D% 3.3oo qFqp 3, /6, 5 Reqrd. &,- 6y- 4o YEs No r/ L) F].o-od P]'ain .{L 2l Perceflr Sl_ope (< > 30$) 3l GeoloEic Hazardsa) Snow'AvalaDche t-Jo-b) Rockfallc) DebrisFrm il) weE.IaDds x-th- Yes No ,/ 230 Addition?Addirion is used ti rh-Eis reguest?-_Jl*.*_ Previous conrri tions of approwal {c}reck properEy f ile) : __ OaL Z.3.tD- + 4zs =_ZJ.&F t,40 * gE -_!,%_ Prone Sides Rear view Corridor ErcroachmenL: Does Lb,is le(iri€u L irrvui.ve aHow nuch of Lhe atlowed 250 (3oo) (soo) (eooltltrof t.4T-r[------ PermiLted gl.ope 8t proposed slope-1fu[ .'t"15' {tot A].lowed I \-t(30)r33.1/ tl,-Tg_ 13' 1{.7Lt*h 611 26' 15' 15. ReLaini-ng Wall Heights . Parking caragre Credi t, Drive: Complies with T.O.v. IJighring Ordinance watser course Sei,back (30) (s0) Do Finish Grades Exqeed 2:1 (5016) gDvironmea t aI./Ha zards : E:r<isE.ino 0r/16/97 17 204 TX/RX N0.6567 P.001 f CASH DE Legal Subdivision Date of Address: DEVELOPER IMPROVEMENT AGREEMENT 1b: and among ereinafter called the "Devoloper"), and the TOWN OF VAIL (hereintsfter called the nTown"). WHEREAS, the Developer, as a condition of approval of the tTI-a li fi'o,,t- plans, dated 6/ t./ ,1q-h, wishes to enter into a Developer lmprovement Agreement; and WHEREAS, the Developer is obligated to provide security or collateral sufficient in the judgment of the Town to make reasonable provisions for completion of certain improvements set forth below; and WHEREAS, the Developer wishes to provide collateral to guarantee performance of this Agreement, including constructlon of the above-referenced improvements by means of the following: Developer agrees to establish;a cash deposit with the Town of Vail in a dollar amgunt ol $J41@- (125o/o ol the total cost ot the work shown below) to provide securlty for lhe following: IMPHOVEMENT Q-olr'he.,'- o!. . , ----------::_ b$. NOW, THEREFORE, in consideration of the lollowing mutual covenants and agreements, the Developer and the Town agree as follows: 1. The Developer agrees, at its sole cosl and expenses, to furnish all equipment ald material necessary to perform and complete all improvements, on or before SOq- el ,lQqb-. The oevetoper shal comptete, in a good workmanlike manner, all improVements hs listed above, in accordance with all plans and specifications filed in the office of the community Development Department, the Town of Vail, and to do allwork incidental thereto according to and in compliance with the following: a. Such other designs, drawings, maps, specifications, sketches, and other matter submitted by the Developer to be approved by any of the above-referenced governmental entities. All said work shall be done under the inspection of, and to lhe satisfaction of, the Town Engineer, lhe To,,rrn Building Offlcial, or other official from the Town of Vail, as affected by special districts or service districts, as their respective interest may appear, and shall not be deemed complete until approved ancl accepted as completed by the Town of Vail community Development Department and Public Works Department. 2. To secure and guarantee performance of its obligatlons as set lorth herein, the Developer agrees to provide security and collateral as follows: Page 1 of 3 to A cash deposit account in the amount ot g 47oo to be held by the Town, asescrowagent' shall provide the security for thd improvements set forth above if there isa default under the Agreement by Developer. 3. The Developer may at any time substitute the collateral originally set forthabove for another form of collateral acceptable to the Town to guarantee the faithful completion ol those improvements relerred to herein anct the performance gf the terms of thisAgreement' Such acceptance by the Town of altsrnatlve eollaterjl snat ue at trre iownt sofediscretion. 4. The Town shail not, nor shal any officer or emproyee thereof, be riabre orresponsible for any accident, loss or damage happening or occuiring to the work specified inthis Agreement prior to the completion and-acceptance of the same, nor shall the Town, norany officer or.employee thereof, be liable for any persons or property injured by reason of thenature of said work, but all of said liabilities shall and are nereOliasir_rmed by the Devetoper. The Developer hereby agrees to indemnify and hold harmless the Town, and any of itsofficers, agents and employees against any losses, claims, oamages, or liabilities to which theTown or any of its officers, g.sg|js or emproyees.may become subject to, insofar as any suchlosses, claims, damages or liabitities 1or ictions in respect tn"teoiiinai-"rise out of or arebased upol any performance by the Developer hereunder; and the Devetoper shall reimbursethe Town for any and ail regar or.other expenses reasonabry incurred by the Town inconnection wilh investigating.or delending any such loss, crlim, oamag6, ti"oility or action.This indemnity provisio-n snit oe in addition to any other liability which the Developer mayhave. 5. lt is mutuaily agreed that the Deveroper may appry to the Town and the Townshall authorize for partial release of the collateral deposited "iiinine iown tor each categoryof improvement at such lime as such improvements are constructed in compliance with allplans and specifications as referenced hereunder and accepted by the Town. Under nocondition will the amount of the collateral that is being held be reduceo betow the amountnecessary to complete such improvements. 6' lf the Town delermjnes that any of the improvements contemplated herein arenot.constructed in compliance with the plans and specifications set forth heiein by the date setforth in paragraph 2, the Town may, bui shall not be required to, withdraw from the cashdeposit such funds as may be necessary to complete the unfinished lmprovements. TheTown shall release such funds upon the written requesf of the staff of the CommunityDevelopment Department stating that the improv6ments have not been completed as requiredby the agreement. The Town shall not require the concurrence of the devetoper prior to therelease of the funds, nor shall the Town be required to verify independently that theimprovements have not been completed as required by this Agreement, but shall release suchfunds solely upon the request of the communily DeveiopmeniDepartment. It the costs of completing the work exceed lhe amount of the deposit, lhe excess, together with interest at twelve percent per annum, shall be a lien against the property andmry be collected by civil suit or may be certified to the treasurer of Eagle County'to be collected in the same manner as delinquent ad valorem taxes levied against such property. lf the permit holder fails or refuses to complete the cleanup and tandscaping, as definecj in ihis chapter, such failure or refusal shall be considered a violation of the Zoning code. 7. The Developer warrants all work and material for a period of one year after acceplance ol all work referred to in this Agreemenl by the Town pursuant to section 17 '16.250 if such work is located on Town of Vail propefi or within Town of Vail right-of-way. l|me t0 time, provldeel lhet such amondments be In wrltlng and sxecutedby all panies hereto. Dated the day and year first above written. Page 2 of 3 I t -v STATE OF COLORADO COUNTY OF EAGLE STATE OF COLORADO COUNTY OF EAGLE updsteC 9/20/!91 Witness my hand and official seal. My commission expires: Wr:X1i:resyevetoe:rffi emzlPreementwasack{gyled#Eoremeh'0. Witness my hand and officialseal. My commission expires: fu5 ll A il/aL-- PLANNER, COMMUNIW Page 3 of 3 oz F = lJ.jI o rn @ a!,ul ltJu- F = uJ /b/s tlor ,alz la/zt ->r? o\ v z ts rJ) z P Js trt!o (9z d = utF o F Fa 2 =o ozz olrl|- z o =f f d) c6 ozz c l+.9 ldQ^ to3[ li se\ lr3* \tE .F g. N! q) (tt op (5 .Do .5 EE6 E8 c.2o_ x.:F] ;(DrJ](r)@€cr)N(fl e q 3 '-oo6 -C -rq)$NF L = uJ z o @ Y UJ z J.L f- tu z dl =l 9z IollJ = {rl z tr r.lJ o c 3 LU UJ z UJ o- Lu lz x F uJo (t) UJ UJt! F = uJ(L J F =.Y'; >= c96 eEt Dt-:e P$'Et\'\ (a.ir\T (9@zH F:r F. OO-r Q &XO €co '6Hoc(,Af'{ H z rl C) z o ) G ouJ 6 z.6 =lJ J 2 IJJ: E E€;A*.€8E: €aeP5 EiseEo.(!o.-:o=-o"(!:o-! 9:APF IEEPev(/).eOO Ee 5 H"^o6:'-X' EstS= - a; q; !=o(,c ef;;=E € Ei:ic - :*- >r=Eoo3;8; e EEgg3 NOtrvntvA F t-.F F '' tI.rF Z Z L.roooEF^<hzt-ai=;E6ocix66 g' ozXE* s :>ei=c 9 g EEioftEiN(J (\l =>E -I IH FJ H F Ff .{. & O{ ah rqE .A i EHHB F. z tr tt_ E. UJo- @ t! (L !uE zo troo X I!(J uJc-+z i !z Az -Fdo3frOI tz)z aF oo oI(-) X |(X X lo Fa z F J CD z r<( u,Jo rl:l 2l zl o uJo alJ uJzo F (r uJ(L .J z EooH*?:o9 l) CE utz if- zo F -Jl z < =t IJJ o tr z tr luF =qrz LC)OO u)z z UJF a(I)o-zo F IIJY IJJdl oF-:o\FO\ =-'E.uJoa! -itl- ..oE;-o-^zvo rVI Fr HF,oEz6 z z3 oP E =Fi=z-f=F-dPE !Dt )..i5 ==idd= tr E lll o-t!o uJoz oo F E o- JFUJ:h=f(r()' IJJ>(LOl!9o\UJ;<[:> l!'J IL UJ F cotclo q' (l) c E EoIJ o E =Elrl o-zIF() EF(nzo(J =.1 EI ililol zl 3lolFI =.1ol uJl 5I al>l bl zl 3lolFI I I I I zl c;lull :l al>l r|-lol 5l sOl uJFI F I I l\TI tt)oll lnl a IXI FCI Iol Iv)lull -rrJt t{ al< El o j><= =(J I "lrllI r'.1PI<lHI-l zl<l =ldlFll g 4 & I ct) 14 rrlF Hu) ui z Nrl rJ\ ra I @ lltl l?l I .J. IlNl l-l9"1azl HslarrltJlq=l .q u-ltol9zlgpl ol =.1 OIull 5l ?l>t bl zl 3lolFI zts- =d!zrr-o o F Fz 9z Io LU cir =Fl-o2 E -,r O<F uJ<zE (tZo J 9 F() UJ F UJF I O J<O rir tllJO / FEt] Enzt !lE tr z q io\ tr NRI RS5\g\ N 6, \ -\\-r > E\;trJ-- *v-I ! \ AH <t \n a =l lqz rl E;Ui- <9I hdit F; f I t E tiIH tE- =-rtt>(9.., !lF =ozo9-o-ot zo Fq*d6FG2o6|:QZ*< |rIta,oIt. .,i E{E1 E-g tstsl|fEg< -lro(. YZF< Efr 41 Q2ZA<i oriZqtx9 o.l.-{ EE<t v(, ul65 ENd'r( 6 iED EH$ o ul ul o(J2t I Er lrl 0. t! z I oJ -f o -l > lr.e) -, -etl- R \ Lt { \-=t \ \ lnun F/z- box r oo vail, colorado 81652 3O3.476-5613 PLAN CHECK 24 July 1973 0ccupancy Group l/J Fire Zone lll Type of Construction V Va I uat i on $ 85,942 .00 The fo I low ing items have of the Un i form Bu i ld ingprior to the issuance of SHEET 2 2. SHEET 3 t. 2. SHEET 4 t. 2, SHEET 'Framing aroundjoisfs. Sec. STAUFER RES IDENCE Jerry L. Aldrich been noted to be in violation Code and must be corrected a Building Permit: Garage area must have 120 square inches of vent area Sec. 1504 Wood beams enter ing conc rete requi res *rtair space on top, sides and en ds. Sec. 2517(c)5 Handrai ls must return fo wa I I Sec. 3305( i ) Mechanical vent in bathroom Sec. 1405(a) Roof beams must bear on wall Sec. 25 18(e)4 Trusses to be des igned for 65/ l0l l0 f i rep lace req u i res 25t8(d)4 GENERAL NOTES doub le cross SHEET I I tr'lood beams ente r i ng concrete requ ired jrr air space on top, sides & end. Sec. 25 17(c)5 PLAN CHECK . STAUFER RESIDENCE 24 July 1973 Page 2 CLARI FICAT ION REQUI RED SHEET 3 Ventlng systern for dryer and range. SHEET 7 Structura I deta | | for attachment of rafter to wall at Section ilD'Dil GENERAL NOTES SHEET 6 Cantilever detail. SHEET 8 Understai r space encloser. ADDITIONAL INFORMATION REQUIRED SHEET 2 Soi I beari ng pressure for co lumn pads. SHEET 3 P I umb i ng deta I ls. SHEET 8 6 x l2 wood beam support. DESIGN REVIEIV BOARD DATE OF MEETING MEMBERS PBESENT: . SUBJECT: ACTION TAKEN MOTION: VOTE:FOR: APPROVEDT --.- DISAPPROVED: SUMMARY: 4 f.la.---SFCONDED BY AGAINST 61 /3 ar 36/ 4*dla/,s' tt V 7 N. CERTIFICATE OF OCCUPANCY AND COMPLIANCE Vail, Coloraa" -l-?.:.2-.---. -ts.!2- Permit is hereby granted.-f--' -T".--ll-...--Tla_lm.+.g.s_,--J-r-.__.-_-__--- - to occupy the ,building "r--.,i.lS!-e--I'.+-lp.r,ly.-I!.f-p.id-q.r_r_e-q on Lots "....-1-..-.....-..-- --, Block.-.? 1!1 l_ili:.-g..... Addition. Located in --__-..--.8-t s-identi rl --- zoning district. The address knor,r,jn as rrtarm iqan R oad Applicant shall maintain said building in accordance wirh all Present or future ordinances wich respect ro sanitation, buil_ Building Official C€RTIFICATE OF OCCUPANCY .AND COMPLIANCE Vail, Colorado Jt:.'l.v-.-?.]- t p 7.,9 . Permit is hereby granteU. --5-." T.. - -_H-._ --T-a-ln.ag.e__ , ' ro occupy rhe building *...lills.1.e. ..fglnily_.. on Lots ----.-8.--------------, Block___.-_.- --- -_S_- -_-- --- _---__ Addidon.F Located in -..-.----.-.--- i zoning district. The address knon4r ., _.... -i l.g-T_ti gg.L..i:g.g.9. Applicant shall maintain said building in accordance,rnth allfuture ordinances with resgect to_ sanitation, buil-Present or Buildl-ng Official a APPLICATION TCIR BUILDING PERMIT THE TOWN OF VAIL (Applicant fill in thle scctioa only) Date of Application _E- Address T"r. No..?82.G3!L Addregs Tel. No, .i/--{.f 'f Addrees City 6"-rilr- Te'l. No. 4tt4- BUILDING INFORMATION New Addition Alteration- RePairs. Type of occupa' cy-ib-- (Al1 parte of building)t{oF Bo No. No. .0!0 tU,.l' l t Lot Block Subdivieion Approval perrnit. $_ $ .n.":;'w slrlto Check $-- Amount Fiaa1 inepe"tio._ TCertificate of occupancy & compliance EffirncDnarNsIc-Nqffi;;;^r'nr.,f,sya; No of storlesL:Ft. roomel--No. baths- water closete iL of of (Gircle correct claa eificationl . Type of conatruction I. U. III. I V@ . Occupancy group A.B.C.D.E.F. C.HA| . f)Signed d,d. /W (Permitteel by planaing and architectural control committee to obtaln buildiag 2/f - fr,4"t Date BUILDING INSPTCTION Receipt otetans t-/@l Approval of Plara J'.f '22 2 sets reouired) Amount of Permit Pee $ 32.to Pald: Caah Paid: CaahAmount of Clean up Fee glJ.r6i Date perrnit iecued Zarrl tt lVZo Tap fee paid No. of Familiee ESTIMATED COST O F CO NSTF.U CTION Jl4g4t,(MaterialE & Labor) Congtruction clean-up - - Tll"{93'-i ,. r'rYlilUfl Eit; 14t211,'rOI .ir{.IA ,rIAv'{5 vlv!' )"i: a-HT (1'lno nc;lire;.. eirfl oi Ijrl tne tilccAl 7i',tI f n' 1)l/) {rfl OI+ir-lJIil i c.:iiiirhA ,r' ll'l i icit.:.:rr,. it rsll A ..._- --__tt ?n.6qiif o,) 1o oelT t :::: ii..i'tci i r, rl ' 56 f '.' 1 ' -l li r.r... l r 'll eril<>'r. lt .tV IL :1 ,' 1.' i,/:rto61 I t_'r ,,.','i e Js e o-i,: .r:,f :iw i.r .ol4 __-aiiii,,;t t; -.;'4 l'P')c il" r/l),_i'ra'a|l.,'tf ]r111ii14 j} -,Ir1 i r od l .J ,.1 : l : ,'r ,rlsi'l j .T, ri.H.O.-:! (rrcilecillaastf, t:. . rror.. sleri )f i .ilT .lt.I noillu"rJr,i.llr li] ar-i,(T .ii .fl .l).1.4 guorg \"1r!.RqutrC lr s: rI. ilj g t0fsr'',{i:' 'i:r-lc.rI: n()i ! )''1lenr)3 ctc r! o1...r:i,1,1:;,2 d qrnnqr, r 1i. r"' l Sairt.qslg Y,; Ir'v('1Cq A .li lrr.reg :!oiJ?so"r.i i+i::; q .o 1o 1'Jr ril i i r.rp h 1\. !.rlt ,.' 'r : li '.-':';g 3Jr([ -._-.--J-_,:.: :-'1bb6 prriblisa --r-F+ to . .t -. ncr3; :llf tictl i -i llc ii.1 . '' 1 .grtSt,[. : r.!1 bb ,. .b't_-.-="\*-::i, ftiP ' c eer bbr\ * t )B UILDING PERMIT Vail, C olorado Pe rrnit Dut.--/eceA_&--re 2d Permission is hereby g'^ftud M, f. fc n n.l, aa 4,-t .tfu.-t" ct-t/r-of a 2 storv crU;/,Lt "". -r ddre e e 'Iype of Construction -E Grouu- J^ Contractor -i pproved In accordance with the C omrnittee, subiect to Protective Covenants, provisions set Iorth bY the Vail the rules and regulations as set and in cornpliance with the 1964 -l rchitectural Control forth in the Vail Village Uni{orm Ruilding Code. INSPFCTICN RECORD (For Departrnental use OnlY) d INSPECTION ..\PPROV,A L COMMENTS DATE & SICNITURtr ITOUND;\ TIONS FR.^ MING f'IN,rr L o0 trl ROUGH 0) I'r FINA L ROUGH FINI\ L ot); aq O' ROUGHu0 r! (,lr z'r FIN.^ L / ,AP o PLIC o RMIT BUiLDING INFORMI TION New A ddition BUILDING.DIMENSIONS No. of stories u ffiZ; No. of roorns .y' No, baths 9 No. of water clos ets__-a__ /)'No. of l.arnilLes_-tr!)fu ESTIMATED COST ROF CONSTRVCTION Lc,eed. eo (Materials & Labor) ti OJ E Eo IdF+|F Building addre s s Date of Application A - /o ! 6? Name P ddress City 6Tel. No. Name A ddres s City Narne Lot BIock Subdivision Addr".. F.o. A)J SVt City doia d^?r'. Tel. No.4lt -{(t? ATION FOR BUILDING PE THE TOWN OT' VAIL licant fill in this section onl INSPECTION RECORD (for Departmental use only) APPROV! L rd l)uD y)o!)rlA (Circle correct classification) -A.Type of construction I, II, ffi, iV,(y/ Z. Occupancy group B, C, D, E, F, G, J $t\ Rhf\lIh${ll {rJ }..o (0 o !,).P (l, |J L(uu I E rd() (J c o lr+to E o co +,a q) od dc ft{ (t q) trlF .o q)to tt) ,.op. {u .lta g g, .0o .ii .n 0: {+ {) Q) +t F tr cto 4.1 \\ I \ I\ q) d fl. d o ha,ad t (lt o c)oq) M fit t{ o q) ru r{ ,1 ilgp? 53 H$ HE;8<9 "u? z2 zd, zEen7.,rop,9 (J u d H :l\ COMMENTS DATE & SIGNATUREINSPECTION FOUNDTl.TIONS A lteration Repairs Type of occr:rpanc1l -A rea of Lot I(J- 9i .:;.d ox trJct6.d +' d 0.)+rbo +l tr altr7 ri o+r? o'1 >O lrpho -;prt6oe3 ".8hn!6 a5 -..a!'6<.!.c, z F,'u H U)zH z Jl-l lr.l 0)t-{ d ho U) rna (t l'!{ d 14 ho d tr dc FC).Io !)t{n. (/) tr k i,, ,Xc, ato F oddtr Eo uijud'd>trq)(d :l o+ltr q) q) v, a\tol{d Lo g' fit o, o o tr lr {) FRAMING FIN^ L ROUGH FINA L ROUCH FINA L ROUGH I"INP L \ Hanch ?3, lg70 Mt. E. T. tt. TalnageVall CO Dean lln. Talnagc: Although thc plans fon your ncaldcnce on Ptannl.gan Roadonlglnally indicatcd a two-fanily Btructunc, it has coneto lly attentLon that it nilght be uaed as a thr€e-fanllystructur:c when your additlon ta conpleted. Thc zoning fonthLs anea llmLts uBage to two ltving unite. Tha dwellingnay not be occupied ae thr:ee Bepanata living unita wlthkitchcn facllLtLcs. Thencfona, th6 downataine po:r'tion ofthe maln pa!.t of the house should not be nented outeeparately lf the new addltlon lc nanted as a acparatcunlt. I an eura you ane alneady fanllian with theae negubenents,but thought it dsslrable to ccnd thlg nenlnder. Pleaecaontact ne if you have any questl.ons. Slnccrely, THE TOI{N OT' VAIL Sfgn"tc F. Blaks Lyneh Torn Hanagen FBL/oar EVERETT / ZETGEL 2305 CANYON BOULEVARD BOULDER ARCHITECTS AIA coLoRADO 60302 3o3 444 257r June 23, L969 Charles G. Bynum, P.E. Buildinq Officiai. Town of Vail ColoradoP. O. Box 531Vail, Colorado 81657 Re: Talmage ResidenceVail, Colorado Dear Sir: This letter is in response to your l-etter of June 11 , 1969, which item-ized certain discrepancies in the plans for the Talmage residence. Thefollowing are our coments and/or proposed corrections to these dis- crepancies: l. Enclosed, please find a detailed survey of the Talmage property showing approximate location of the residence. 2. Found.ation wall reinforcement will be: vertical bars: #5 G 48"with voids filled with concretei horizontal bars: #6 @ 48" con-tained in concrete filled "U" blocks. This anount of steelyields 0.J-9 square inches per square foot total reinforcing. 3. Door from garage closer. 4. Bunkroom on lower area well. 5. East bedroom on main Level has 3-#W2N3 windowsi west bedroom (not to be buil-t at this time) has t-#W1N3 window. 6. Superficial floor area of east kitchen is 106 square feet; super-ficial- floor area of west kitchen (not to be built at this time)is 32 squ€rre feet, which we feel- is totally adequate for a vacationhouse. We hope that prior to the time this kitchen is built, thismatter can be resolved. to house will be a L-3/4" solid core door with leveL will have one Anderson #W2N3 window in an Mr. C. G. Bynum, P.E.-2-June 23, 1969 7. A1I toilets will have a minimum clear space of 30 inches. We woul-d like cLarification of your comment that basins also need 30 inches. We are not aware that the Code requires this space,nor can \^/e see where our plans anywhere show l-ess than that. 8. A11 guard rails on balconies shown have no openings less than9 inches. 9. Windows in the west bedroom on the upper floor will be changed from 2-418 windows to 2-422 to increase minimum open dimension beyond that required (22"). A11 other wind.ows either complywith the Code or are not to be built at this time. I0. Both fireplaces will- have hearths in accordance with the Code. 11 . We are attempting to find why a letter of approval from theArchitectural Control Cornrnittee has not been sent to your office.It is our understanding that the project has been approved. In accordance with our telephone conversation of today, I will meet you in your office at 1:00 p.m. I Wednesday, June 25, 1969. Very truly yours , EVERETT/ZETGEL, ARCHITECTS, A. I.A. Project Architect SIG:mcs cc: Mr. ?{m. Renner o "aI .Y ,l ltarro 7+.2e :xbn-\__ /aaa _ )/* 3- 2f* e.fc - /2 * 2.5'g - €. oa ?2. ee 12.5P /5.t>o 22.feta a fVt cva 6o, nr /tt,ta -Zc.-tr,P 77. 2-f -.?/a Cft 2J J.zt 2f. eo Q/e* a7 3 a ?, z-f ,6/e/t I t w. L.RENNER trENTRAtrTt]RAax 37'7 - 476-sslg . VA.|L, CoLoRADo Bf 657 .-'- TIIE FIIST IIATIC:1'1. l.'.:iK Ct tA6Ln Ca , r' a- tl pLL W. L. RENNER CON'TRACTOR t to D or.r-ur s $*t4-.r-q ar 2v 4<'{. (') /,t' t.| +!n: s*:: ,: a*,..,. -rt - . - -j rNsPEcrroN RDco BUILDING DEPARTMENT VaiI, Colorado Phone 476-56L Notice: Inspections will not b€ made unless this card is posted on the job. -AJ-L subcontractors must be iioensed and sign this -. To Insure Inspection sam,e day call: 476-5613 before 11:00 A M DO NOT COVER UP ANY WORK NOT INSPECIED ca,rd to obtain inspection. Concrete Heatjng Eleslr,iaal Plumbing Dry Wall or I.lathing I It_- I T(| G(|MPLY WITH C(IDE INSPECTION BECOBD Inspection To obta:n in:pections call 4?6-5613. Inspections will be made the same day irn calls before 11 A. M. No inspection will be made on Saturday, Sunday, or legal holidays. Date Approved Rejected By Inspections will not be rnaile until oermit has been secured and contm,c' for has signetl and placed his llcense number in the sPaceo above. Footings 'r/2- F Inasonry Plumbing /q -- tt' Notice: Certificate of Occupancy and Compliance must be ob- tained before structure is occupied. I BUILDING PERMIT Vail, Colorado Pe rrnit Perrnission is hereby granted as 6a/t.tf.r b ce; tf- -.f a *xt story rerlJe nce ! dd""r" /ftrr-3..-. fo. / In accordance with the C ornrnittee, subject to Prote ctive Covenants, Type of C onstruction -T C ont ra cto r provisions set forth by the Vail the rules and regulations as set and in cornpliance with the I964 -4. rchite ctural C ontrol forth in the Vail Village Uniform Building Code. -rGroup r"t" UL*,2 A n-rL Y. ./. .tco-"- -i pproved --/Vail Building Inspec INSPECTION RECORD (For Departrnental use Only) INSPECTION }-OUND,\TIONS .\ PPROVS L COMMENTS DATE & SIGNITURE FRA MING bo tr ) FINA L ROUGH 0) 14 FINI L ROUGH bo; o,FINl\ L ROUGH h0nd 0) a FINII L Ev er ett / Zeige I Archltec ts 2305 Canyon Boulevard Boulder, Colorado 80302 Gentlemen: Plans submltted for the subject resldence dlscrepaneies: 1 The plot plan should lot lines and curve Iot area by D. M. Reason ls lot cove ordlnance. 2. Re u.B.c. 2418 (f) June 1L, 1969 and bearings on nt to compute the the lot area. by the zoning n walls does not meet See Sectlons 2314 (k) 3 and a handout sheet based upon on lower floor has no light or ventilation. ta 3. i'!. 5. A the U. Bj nts. r fronr 6 to house should be 1 3,/8 inch soild Bunk wlth an automatic closer. 405 (a). Bedroom on maln floor shows no windowg. Kltchen superflclal floor area ts less than 50 square feet. We have on hand a request from another architect to amend SecHon 1307 (b) to read, "32 square feet", however, thts has not passed the Board of Trustees as of thls date. RE: TALMAGE RESIDENCE t 7.' Tollets and baslns need a 30 irrch space. 8. Guardralls on balconies should have openlngs no greater than I lnches, Sectton L?L4. 9. Bedroom wlndows do not appear to have an opinable area as required by Section 3320. lO. Flreplaces should have a hearth in accordance wlth Section 3?0a 01. 11. We need a letter from you statlng that the house wiII be bullt ln accordance wlth the U. B. C. and a letter from the Archttectural Control Committee approvlng the appearance. Sincere'ly, THE TO\MN OF VAIL Chartes G. Bynum, P. E. Buildlng Offlclal cc:IvIr. W. L. R P. O. Box 5?7 ValI, Colorado /)v \\. .2'