HomeMy WebLinkAboutPRJ09-0402 B09-0222 . ,Ywr��ll�
--------
------ — -- ���D�I-b�oZ
�63" I
�------ a0"---,��- — -------- I
i � — �
-+--- — • I
I
I
I � I
I I
I li
CIOSP.t I
:�., i
"' I
�
� �
� i
I �edroom ,
: W
II General Scope of Buildin�Permit - Drvwall � i'
Remove tile & drywall above existing bath tub— 72.4 square feet ;
.�__ Drywall total square foot of drywall (2) tubs 144.8 ,
� sembl ��
� Per UL Des U329 1 hour as Y �I ��
� ,� ! Insulate with 3 '/z" Thermafiber SAFB F
' � "m Install Durock (1/2" on interior walls) '�
i X I Existing (5/8" on partition/common areas) I '
� Bath F'an Install '/a"porcelain tile on walls & �' ,
i No Changes ceiling above tub I��
I' No change to existing tub &tub/shower faucet I '
Bath � i
�
'I� n IXW2436 IXW.3321 IXW1536 I�
/56.25 square feet
IXW302124
' � d5"
', � 24.DW Spac' :
in � ..., �� '" --.._.._ ___.._...._..... !i
c� ---
I IBEP24L IXB15WASTEA
._ _�
_ �\
; �;�,_F, �� j
, ��_., w� �
J �
Kitchen °i !'
I �. , � -
�
_ _; ��_�� ' , - I
; , 70 square feet '
I�.. --------- - , i I
I � 60R-BATH-1
__ BF3.
, ._....__ ._ . ,
_
_ _......_.....
i 4 j �> O' O ----IXB36------ IX836
j ' ------ -----
,� - i
_--.—,
------- -........_..
�--- --- _
, _ IXW3021
,
, - � �
� -- -- 5gn �\ i
� `...._„__.. _.._.. _ � I'� I,
-.�� 105" ,
�� M Closet '
, I
-�---
- ---- Eating Nook �
i
� � ' i,
r—
' i
' '�x� Eagle Point �� I T �`� ;
,� �
; ,
' � � Std 1 E�drm Unit � �
'I R, �
' j __ 599 sq�aare feet Total Unit ;
, � ,
o , �, _
� ?� ��� 3/8°' Scale pverall Scope in addition to above
, N �n ?— �,.} I
��°"� `� Remove & install new kitchen &bath
o ��� ' ��. I
�
I �_°�a�� o � �"' ' � == � cabinets, countertops, sinks, faucets � �a:
! �� � d�� I
�a� o � -��, �� U,' ., �
' I �� � '�_� � fD° �� � in same location 1� �
pM 3 cg'�o �+�.�c n� o t�n p�� ,.,� i
° �m�°�°°��� ��� . Remove & install tiie on floor of kitchen F�:�� � �
� � t�=��'���o �� n� < i �
�' � ��a �3 Q�g o a`_+�.� �� �7 baths, 4X4 entry , ^�
��� �
, =�^ �yo.ao�_. � �
�.�o� r fn i_� _. �o �,U � Install wall tile above new kitchen
� ���, @:� counterto ps to un dersi de o f w a l l c a b s � �
� � — � '�
� '� =� � t li h t o v e r k�t c h e n ..
� 11 undercabine g I
� G ����g Room �-a Insta `� ,
� m • v��, sink on separate switch '��
I ;
I � a � « w=g; ?.rn Install new circuit for microwave
i iil � �.-�irt
�, Install new electric devices in kitchen & bat
� lnstall GFCI outlets in kitchen & bath
� Remove smoke detector in kitchen/]iving area � �
' Install heat sensor during construction ���
Re-install smoke detector upon completion �
;
-�-�o� '�-- �
o � � � '
28�� �
� T> � ____ _ — 179° , �
� c�i� �? i
� � zo�„
�� � � ' _ �
1�� --� -- __-
D O � _--
a
ee ,--------. a ""` '" This is an original design and must not be Des�gned. 7/9/2007 I,
All dimens�ons _size designations given are 2O �'�,� ,�e•� released'or copied unless applicable fee has 1 Print�d_ ��1��='��� _;�'
� � �
subject to verification on job site and TECHNOIOGIFS� been paid or�ob order placed. �
� �adjustmenr. to fit job conditions. i� I
i
,I �—''
11 Drawing #: 1 Scale : 0 3/8'_°1'j��
�A-a22Z _ _ ^ - -
F.P 1 Bdrm Un.it