Loading...
HomeMy WebLinkAboutRIDGE AT VAIL UNIT C86127|2AOS 13:28 9789269689 Englneerlng, Inc. CryIIJ(|E)TIOIMC4L Jwc27,2C0.5 Mr. I{en Sontlmd Sortlnd Contrrctorr, Inc. P.O. Bqx 4252 vail' co 8165t Town of Vail LKP EI.GI I€ERII.G I].E o PAGE g2 0,1(RE: Opo HolcObccwrdon & Foundrdo Invotigetion Unit 5C, Ridge at Vail Townhomcs I il60 Ridgc lamo, Tovm of Vail Eaglc County, Colorado ProjcotNo. 05121 0o5 ' oofa OFFICH $[IPY DcrrKen: At lour requcrt, on Junc 22, 2005, wc viritcd the comuuction sit€ at Unit 5C, Ridge d Vail Townhomee, 146O Ridge [.rne, Town of Vril, Eegle Comt, C,olorrdo. The purposc of otn sitc vieil wac to obrenre ud tcst 6e sil crpoacd in tbc foundetion excavation for proporcd addition. Thp cxosvrtion aonristcd ooc Ear,h, sbout 20 fcct long, in a rougbly "L" shape; stepping into thc lot The orte rangcd from about 3 feer to 6 frd, wift onc stcp. Thc c:<cevrtion wao on thc south gide of thc exi*ing tonmhomc, Th eoil oxpo*d st thc bottm of thc hcnoh conrisrcd of mndy*loyty grrvel and ehalc be&odr" Thts soil is suitableftr tlv design furing capcity of 20& psl Foudrtion walls r€taining certh and rctaining strucnrrcs that are l*erally srpported rhorld bc dcrigred to rcsfut an oquivalcnt fluid dcnoity of 60 pcf for an "at-rcst" candition. Latorlly uncrtreincd stnrcturer, rctrining the on-sitc eartbr should bc dcsigrcd to rcri3t an cquivalcnt fluid deocity of40 pcf for thc 'activC casc. Thc abovc dcsi8n rocdrtncodstions rssrme dninerl backfrll conditioos and s huizontal b.ckfill nrr&cc. Srnchargc lording duc to rdjNo€ot structurcs, weight of tcrnponry storcd cmetruction mrtcrilb.od €qrdpmmt, furclfuid brckfill md hydrostatic prcesurc &rc to undlaincd brckfill should bc incorpor,rrcd in Sc dorign. To redrcc thc risk of surfacG wstcr infiltnting the foundation gubosil, we rpcommcnd inrrallation of a fottndation pcrimctcr drain. Tho forrrdatiur pcrimetcr drEin should cou6ile of r 4-inch diurrcilrr, pcrfurrted pipe, dopcd to r nritrhlc gravity orrtlcf, or io I rufiip prmp locariorl at e l/4 itrc,h per foor fc flqiblc or at a t/E of an irch for rigid pipc. Thc drain pipe rlouH bc leid ovcr u impenrriour moisturoturi€r gluod to the formdation wall ana covcrai with a minimum of 6 incher of -3l4-irch ftcedreining grmuhrmatcriel. Ocolcxtite (Mirafi l40N or bquivdent) chould be uscd to covor tho frcaai'iiing grEvcl to Fcvcnt eiltrtioir alrl cloggine oftle .lrah. lto backfll abovc tl: drain ahould uc gcnuLr md;rl to within 2 rcct of urigr;r,Dd rwfaoc to prcvcnt a buildup ofhy&ostafic preseure. P.o.Bor 2837, Edvudq @ 81632, (920) 926-9088 Tcl, (9t0)9@0E9Frx AV27/2995 13:28 9789269889 Mr. KenSortland Pago - 2, hoject No. 05121 Juttc 27, 2fi)5 Extcrior bockfill should be corryactcd at or neu thc optimrur moisturc contqrt to at lcast 957o of the maximutr standsrd Prcctor density undcr pavcm€ot, sidewalk and patio areas md to at loast 90/ of the maximum stardrnl Proctor deneity undcr tadso@ arcas. They shorld uce mcchanical methods of oompaction. Do not prddle tho formdation excevation. Thc sitc sufloundfuU thc building stucture should slope away from the building in aU dircctions, A minimum of t2 incheg in the firgt l0 foet is recommendcd in upaved areas, and tlucc inchce in lhe frd l0 fccl in parrcd ueas. The top of thc grmular formdation bocklill should be covercd with a rnfuimum of I fmt of rclrtively impcrvious fill to rcducc tre potential of curfuc watcr infiltruing thc foundation subsoils. Sqfrcc watcrnrnndly ihaioittg toward 0ro pmposed buitding rite should bc divcrtcd around urd awry frur it by moans of drainrgc swelcs or other rpprovcd methods. thc rcof drains md dovm spouts should extend and dicohrrga bcpnd Ore limits of tho backfill. fhis rGpott has boen prcprrcd ecording to locally acccpted profcssimal gcotcchnical coginccring standrdr. Thcrc ie no othcr warmty eithc cxprccscd or implicd. Sfurccrcly, LKP Engineering, LKP EFEIhEERI].S I1€ v PAGE O3 ,t.ft'q LuizrPqtrovska" Pr€sidcnt tr\WE I 2.!XF0J I 2t opcnr.frdvpd $t.,%*r ti: LKP EnginocrinS, Inc. REPT131 ArF D lnlbrmaddl 4:12 pm vail, co- clry ol - RequesEd lnspec-t 9rEr Ugnday, Ocbber 17,2005' Inse€cton Areal SH Slb Acklr.ssl 1460 RIOGE LN VAIL RIDGE AT VAIL TH, UNIT C :*iL- - o.""ffii BELE. suulg DIL!.C}|ARLESA. DAt{lCl ELECIRIC Phone DANS ELECTRIC PhONE ELECTRICAL FOR R@M ADDIIIOI.T AIS KITCI#N LIGT{IS Run Id: 3796 AMF SlaTs: ISSUED Incp Aroa: SH 970"39$1173 97G39Gt173 Acttvlty: CorSTyTa: cllvner: Apglhard: Coi$rr&r: Dcccrlp0on: RcouesEd lnspecdon(sl lbm: Requerilor: Coninre 3: Asslqned To:- Acflon: 190 ELECflnal DANICIELECTRIC wll cofl 9]+1001 for.cc.:s SliAff.l Requcsted Tlme: 00100 At- Phom: gt+1001 EnfiercdBf DGOLDEN K Thne Exp: F t oufl'-frt I n2 ^+r' fc "-a Ch e,uq e K' ;/- /!-4t// ?A'-/4 1- 'GFT TtTc v ) 5G, 001(tlD lns!.cdon Hlsbrt APAPPROVED REPT131 Run Id: 3796 4:12 pm Vall- CO-ClOr Of Requesbd Inspect Dab: lfondry, ffib€r 17, m05- lnsoectlon Arer: CG Slte Addre$l l,{60 RIoGE lJ{ vAlL RIDGEATVAILTH, UNITC AEEE@r$e! Aclhrltti: lrlfft-Oil04 Tvoe: &MECH SubTwo: AMF Sbtus: ISSUEDConstTnl: OccrFo'Ifty: (6e: InspArea'CG olrvriet: DILL.CMRLESA.ADolkrnt R & H lrECflAt{CAL LLC Phom: (970) 32&26$l Co'nha6r: R & H ltECllAt{CAL tLC Phom: €70) 32&26S D..cdp{on: Ot CTyIDRK HEATI}.IG SYSTEM FOR STIJDY ADD|nON. ADD 1315 SO FT OF GRFA r'r AIReou€sbdtnso€cdon{sr /I f poPD ltem: 3ff1 llECHflnd RequestedTlme: l0:00At Rcqu€$r: R&HMECInNTALLLC - Ptptr: gl+looi ColtiBrnt3: wlll ca]l 90,1-1fl)l tor acc.tt Asslgned To: GDEIICKII Edend By DGOLDEN K- Acilon: llme Exp: Item: 315 PLMSGaglbm: 320lbm: SX) lbm: SrlOlbm: 39, Acilotr: APAPPROVED Actlon: APAPPROVED TLtu,oe C*'fr. f F**t 6, FItv 1",-* +. 'f)Le'-'^* </d lW",u/ z/a{ lnsoccfon HlstorY hsm: 2fi) MECF+Rouoh ItBm: 3lO MEcr+t|3r0ng * ApprowO - 0907/05 thspccb,r: JRM '- Comment APPROVEO Dt CT|l.lG JR"Appowd- TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2t38 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: MO5-0204 Co: oo& Job Address: 1460 RIDGE LN VAIL Status . . . : ISSUED Location..,.,: RIDGE AT VAIL TH, UNIT C Applied . . : 0910212W5 Parcel No...: 210312110003 Issued . . : 09/O6/2C05 Project No : ?k:Os- -60\ I Expires . .: 03105120{J6 owNER DrLtrJ, CIIARLES A. 09/02/2005 807 S WARSON ST I-,OUIS MO 63t24 APPLICAIim R & H MECI{a}IICAIJ IJIJC 09/02/2005 Phone: (970) 328-2699 PO BOX 810 EAGIJEco I l_531 License: 184 -M COMTRACTOR R & H MEeHAlrrcAIr LLc o9/02/2o0s phone: (970) 328-2699 PO BOX 810 EJAGI,B co 81531 Licens€: 184-M Desciption: DUCTWORK HEATING SYSTEM FOR STUDY ADDITION. ADD 131.5 SQ FT OF GRFA Valuation: $1.000.00 Fireplace Infornation: ResEicted: Y # ofcas Applienc€s: 0 #of Gas Logs: 0 #of Wood Pellet: 0 Mechanical-- > Plan Check-- > lnvestigation- > wilt cdl---> 920. 00 Resularant Plan Review- > 95.00 DRB Fee------------ > $0 . 00 TOTAL FEES--> s3.oo So. oo Total Calculated Fees-- > so . oo Additional Fees------ > S28 . oo Total Permit Fee------- > $28.00 s0. 00 $28.00 $28.00 *|l.*|tti*tt*+*+.+*.:t+:t't.{.lt'|*{.**|,t.*il*|it|t.+|l.++*+{..*'.:}:t't'|.*'|*|'.lt*+'t**..|*|**|.******. ITCM: 051-OO BUILDING DEPARI.I'IENT o9/o2/2oo5 JS Action: Ap IECM: O55OO FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BL,DG.): FIEL,D INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPIJIANCE. Cond: 22 (BLDG.): COMBUSTIONAIR IS REQUIRED PER CHAPTER 7 OF TIIE 2003 IMC AIID SECTION 304 OF THE 2OO3 IFGC AS MODIFIBD BY TOWN OF VAII,. Cond: 23 (BI.,DG.): BOTII.,ER INSTAI.I,ATION MUST CONFORM TO I,'A}TUFACTURERIS INSTRUCTIONS ATID CHAPTER 10 OF THE 2OO3 IMC. Cond: 25 (BL,DG.): GAS APPIJINiICES SHALL BE VEIITED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BL,DG. ) : ACCESS TO MECIIAIIICAIJ EQUIPMEI\IT MUST COMPL,Y WITH CHAPTER 3 OF THE 2003 IMC AND CIIAPTER 3 OF TIIE 2OO3 IFGC.. Condr 31 (BLDG.): BoTLERS SHALIJ BE MoITNTED oN FLooRs oF NoNcoMBUsrrBLE coNsr. IrNLEss I.,ISTED FOR MOI'NTTNG ON COMBUSTIBIJE FI.'OORING. Cond: 32 (BLDG.): PERMIT'PIJANS AI,ID CODE AT.TAIJYSIS MUST BE POSTED IN MECIIAIiIICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILTER ROOMS SHAIJIJ BE EQUIPPPED WITH A FIJOOR DRAIN OR OTIIER APPROVED MEN.IS FOR DISPOSTNG OF IJIQUID WASTE PER SECTION 1004.5. DECLARATIONS I hereby acknowledge that I have read ttris application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comfily with all Town ordinances and state laws, and to build this structure according to the towns zoning and suMivision codes, design review approved, International Building and Residential Codes REQUESTS Ft)R INSPECTTON SHALL BE MADE TWENTY.R)UR HOTJRS IN PM. ordinances of the Town applicable thereto. OR CONTRACTOR FOR HIMSELF AND OWNEF BY TELEPHONE 479-2149 OR AT OUR OffiCE FROM 8:00 AM - 4 *rttll+*'l'r'r'r*f ***'i'l'rllf tt*:i:t'r:ittt*f ta{r{rt{'*tttttttt*f *,},}**,r,},r*+{rtttf ttf f ,t+llttttttttt**++++++ TOWNOFVAIL, COLORADO Statement**'|*lf****+'t'tt+*i*t'|'t'|'t*****itf'ttt**i+++++{'**'}**t+*{r**********f****+****++'t{'{'*{'*{'!t't{'**{'++t** Statement Nunber: R050001452 J{mount: 529.00 09/OG/20OSO3:48 pM Palment Method ! Check Init: IJC Not.aeion: #1663 3 /R&H Mechanical Permit No: M05-0204 Tl4)e: ITECHANICAL PERMIT Parcel No3 2103 - 121- 1000 - 3 Site Address: 1460 RIDGE lJlil VAIL I,OCAtION: RIDGE AT VAII, TH, I'NIT C Tota1 Feea: $28 . 00 This Payment: $28.00 Total ALL Pmts: $28.00 Balance: $0.00*lt*t't************ft**t****a*aa*{"}*X't'}**l***a++lt****a*******l*ltt*********f*t***l*tal+**+l++ ACCOIJNT ITEM LIST: Accorrnt Code Description Current PmtE MP OO1OOOO31111OO MECHANICAIJ PERIIIT FEES 2O.OO PP OO1oOOO31123o0 PLATiI Cr{ECK FEES 5.OO wc 00100003112800 wIIJr CaLL INSPECTION FEE 3.00 Sep, 1, 200t 1l:46Alrl R&H |[4ECHANICAL APPUCATION WILL NOT BE ACCEPTED IF ITICOMPTETE OR ProJect #: Building Permit#: Mechanical Permlt #; N0,3309 P, 3 . ZS S. Frontage Rd. Vall, Colorado 81687 Prcvide Mechanical Room Layout drawn b scale to inclpdeo Meclranical Room-Dimenilons .ll- t - r.! i .rr_/ \ i ,. .,1 f :t:!, gitil Permit wilt not be acrcepted wlttrout the foltowing; VALUA MECHANICAL: $ 100O. @nbctt -- I Parcel I ll::=i ' gns tzt t oa"/ t**^,[ft lt par rdo .a.robMd'ess: lLlba P'&a-k) be- Legal Descrifion Lot:Blocka3?Tl Fitias:,Subdfvision: olA v th,! bnd,o**WrP v Engtneer: il Adilress:Phone: Debiled descJi' N..ILrJ.^a lJ<rti.-4 S./fu., , Work,Class: Nerv() Addition( ) Atentjoi Repair.( ) Other( ) BoilerLocation: InFrior( ) Exterior( ) Otheri ) ll Does an EHU exiS, at this locaUon:Ycs (\No( ) Type of Bldg: Slngle.famlty ( ) Dupts( ( ) Mutti-family Commercial ( ) Restauont( ) O0rer( ) nqfrvpe sf Fireplac€s Existing ) Gas Loas ( ) wood/pellct ( ) wmd Buminq ( ) No/rype oi Fireplaces Proposed: Gas Apptlances ( ) cas Log;a ) W - Is Oris a conversion from -! ol{LY********:F:r:F**!t**!r***:F***,*:}**!r:t 1,2005i11:45 &H MECHANICA kL t \ I Svryn 4b FL@IL 0l(anut Ezl 1, ilEil ErtpFGilril{r-'#rteh.-\.-. '{- #,r":h:,T;::*'^ LlvrNovam@ tr I S?€Lt-6Ltt't'el #;tr*;' q"\ 'r* ll / bq ". -9t-/iI / Sep, l, 2005 l1:45AM R&|| MECHANIcAL No, 3 309 P. l Rall lrlrcnilrclLllG POBoxElo - FAX To:From: Nancy PHoNE 970-32&2099-FN( 970-328{234 aqqpAyi_-Jovm of Vail Datc 9lll05 lhone: 97G419A325 Pages:3 fq 97047y2452 Re: 1460 Ridee l-arre *tC Doris Attached is oru pormit application along with a drawing on fte abovo refcrsnced projoct If you havc any questions pleasc feel free to call me. Thank you g,'(rU-A ArPrD lntormafron Requesbd Insoect Date:' lnspecfron Area: Site Address: E0&0176 _ Tlpe: SELEC Occupaity: DILL. CI-TARLES A. DANICI ELECTRIC DANICI ELECTRIC Uonday, Augustz2,2005 1460 RIDGE LN VAIL RIDGE ATVAILTH, UNITC Arttultv: Const TypS: OlrnEr: Applkant Contraclor: De*riptbn: RequesEd InsDecdor sl Item: l2O ELEC*ouoh Requeslor: DANICI ELECT{IC DAVE COm'N€nbj A.M., WILL CALL DAVE Strtn: ISSUED Insptuea' SH Phon€: 97O-3q11173 Phone: 97GGX)-1173 ELEC1RICAL FOR R@IT AODITIOT'I ANO KITCHEN LIGHTS Requested Tlme: Phon€: Ent€r€d By: 09:00 AM 970'3SP'1173 FROT.IT KAss[ned To: SFIAHN Aclbn: _ Tlnc-Exp: iZrullt)I) u,rt lnspecdon HlstorY It m: 110 ELEC-TefiD.Powtr It€m: 120 ELEC-Rouih Itcm: 130 ELEC-Conilult Item: 140 ELEC-Mlsc. nem: 19O ELEC-Flnal W na/,h^ /4//rou(e t ftzf o{ REPT131 Run Id: 3538 TOWN OF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2138 OWNER DIIJtrJ, CHARTJES A. 807 S WARSON sT r-,ours MO 63L24 APPLICAI{T DA}IICI EIJECTRIC PO BOX 7245 . BRECKEIIRIDGE co 80424 Licenge: 114-E CONTRACTOR DA}ITCI EIJECTRIC PO BOX 7246 BRECKENRIDGE co 80424 License: 114-E Electrical---- > DRB Fee----- > lnvestigation-- > Will Call------- > TOTAL FEES- > DEPARTMENT OF COMMTJNITY DEVEI,OPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRJCAL PERMIT Job Address: 1460 RIDGE LN VAIL Location.....: RIDGE AT VAIL TH, UNIT C ParcelNo...: 210312110ffi3 Project No : QQS-oS -60 c( I Permit #: Status , . Applied. Issued . Expires . E05-0176 j65 - oa&J .: ISSUED.: 08/18/2005 . : 08119/2005.: Ail6l2OO6 08/r8/2O0s o8/!8/2oos Phone: 970-390-11?3 08/L8/20os Phone z 97o-39o-tL73 Desciption: ELECTRICAL FOR ROOM ADDITION AND KITCHEN LIGHTS Valuation: $1,000.00 Square feet: 200 *'i|.'**:tt**{.*{|:t|*:i+++**{.t,tl.{||t*tt**l.'|*'*|lt*|i1*'*,t*a'|*'.|||*.**||* ss1.7s $0.00 $0. 00 93 .00 $54 .7s 9s4 . ?s s0. 0o $s4 . ?s $s4 . ?s $0. 00 Toel Calcrlated Fees- > Additional Fees----- > Totrl Permit Fec---- > Pa',nFnts--------- > BALANCE DUE..-----> Approvals: Item: 06000 ELECTRICAL DEPARII'IENT o8/t9/2OO5 shahn Action: AP Item: 05600 FIRE DEPARI'IIENT ******al.***,t**l{.++*++l+*itlltltlll CONDITIONS OF APPROVAL Condr 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CI{ECK FOR CODE COMPLIA}ICE. DECLARATIONS I hereby aclnowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state tlnt all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and stat€ laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. RSQIJESTS FOR INSPECTION SHALL BE MADE TWENTY.FOIJR HOI,JRS IN ADVANCE BY TELEPHONE AT 479-2149 OR OFFICE FROM E:m AM - 4 PM. OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF ***********++********++++++{'*****lfff++f+f*t***'}la**+{'********f'}ffat++*******lr******'t**+++l'* TOWNOFVAIL, COI,oRADO Statement *****t*****t+t*'t*+lr+f++'i++*'t****fiti+++**tat'}*'ltt{'*+++++++f*+*t*******++************.i******* Statement Nurnber: R050001341 Anount, | $54.?5 08/t9/200503:28 PM Palment Method: Check Init: LCNotation: #3092/DANICI EIJECTRIC Permit No: 805-01?5 Type: ELEeTRICAIJ PBRMIT Parcel No: 2103 - 121- 1000 -3Site AddrbEe: 1450 RIDGE Illil VAIII Location: RIDGE AT VAIIJ TH, ttNIT C Total Feea: $54.75 ThiB Payment: $54.?5 Total AL,[, Pmts: $54.75Balance: $0.00 ACCOI,JNT ITEM LIST: Account code DeEcription EP OO1OOOO31111OO EIJESTRICSJJ PERMIT FEES WC OO1OOOO31128OO WIIJIJ CAIJIJ INSPEETION FEE Current Pnts 51.75 3. OO I'J,/VTIWYAIL 75 S. Frontage Rd. Vail, C,olorado 81657 APPUCATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGN -oo.{/ Proiect #: Building Permit #: Electrical Permit #: 97 O- 47 I -2149 (I n sPecti INFORMATION 7zo - 3q0- il? 9Town of Vail Reg. No.: hvtal fu-€orttt. fi< Fax#: 9?O 5 Contractor Signature: COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (labor & Materials) ELECTRICALVALUATION: $ IOOOAMOUI,IT OF SQ FT IN STRUCTURE:f;ta p Assessoo Office at 970'gZE'8Ag or fr#.for Parcel #Contad o9l2 , t OOt) robAddress: l4p fat\M Lf VfulLlob Name: l\U Fnn ho}mott r Work Class: New ( ) Addition K) Remodel (4{ Rgptit ( ) T"'"p P"*"t ( ) ffit *' El'tu ""i" " this location: Yes ( ) tlo () Work Type: Interior 6,Q Exterior (oO Both 6l) @) Mutti-family (.2\- commercial ( ) Restaurant ( ) other( ) No. of Accommodation Units in this building: No. of Existing Dwelling Units in this building: 3 it for a hot tub: Yes ffist: Yes( ) NoExist Yes( ) No F:\cdedBUlLDING\APPLTCATION S\ELECPERM2005'DOC 07t062.005 o o 0 B B o MWNOF Amendment to the 2002 N.E.C. Town of Vail Ordinance 4, Series of 2O05 Overhead seruices are not allowed in the Town of Vail. Underground seryices have to be in conduit (PVC) from the transformer to the electric meter, main disconnect switch and to the first electrical distribution circuit breaker panel. The main disconnect switch shall be located next to the meter on the exterior wall of the structure easily accessible. All underground conduib are required to be inspected before back-filling the trench. In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are accepted. NM Cable (Romex) is not allowed in commercial buildings or structures exceeding three (3) stories, No use of aluminum wire smaller than size #8 will be permitted with the Town of Vail. TOWN OF VAIL ELECTRICAL PERMIT GUIDELINES All installations of exterior hot tubs or spats require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form atbached (if applicable). If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck over 30" above grade, you must also obtain a building permit. If this permit is for installation of an elterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and veriff that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application. If this is a remodel in a multi-family building with a homeowners association, a letter of permission from the association is required. If this permit is for a commercial space, two (2) sets of stamped drawings are required. the above. '<- n-09 Date SignedSignature If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at97O-479-2L47. The inspector can be reached on Tuesdan Thursday and Friday mornings between the hours of 8am and 9am. You may also leave a voice mail and the inspector will call you back. I have read and underc F:bdev\BUILDINGV,PPUCATIONS\ELECPERM2005. DOC 07n6n005 SAUNDRA LEE SPAEH AIA P Ro r Ess I ifi il'Jt?'ro *o,, o * Moy 25, 2005 Mr. Chris Gunion l.C.C. Plons Exominer Town of Voil Building Sofety ond Inspeclion Services 75 South Frontoge Rood Voil, CO 81657 Re: The Dill Deck Enclosure; Building Permil # 805{080 Deor Mr. Gunion: Thonk you for toking lhe time lo meel wilh me todoy. Reviewing oll of fhe documenls togelher, wifh regoid to the property lines, wos very helpful for me lo undersfond ond reiponO to your Lode concerns os well os ollowing the project lo move forword in o limely foshion. The following ore in response fo the Building Sofety ond Inspeclion Services Plon Review Second Check Comments: L lt is unde6lood thol fhe building permil issued for lhis project sholl include lhe condilion thot on lmprovement ond Locotion Certificole survey musi be performed ot the time thot fhe new foundofion is in ploce. This will indicole ihe exoct dislonce from the exterior woll of the strucfure lo the plotted wesl property line for lhe purposes of fire seporolion. 2. Should fhe ILC indicole lhot fhe new structure is within the required 3'-0" fire seporolion dislonce or the roof overhong is wifhin fhe required 2'{" fire seporolion diitonce, the plons sholl be revised fo show t hour construcfion, (in occordonce wilh UL ossemblies), of ony encrooching struclure ond lhe woll ond/or overhong sholl be consiructed in occordonce wilh lhe revised plons. 3. Should lhe ILC indicole thoi ony porlion of lhe new sfructure is wilhin the 3'-0" required fire seporotion distonce, ony window opening fhol is encrooching into lhe 3'- 0" hre seporotion ond within the oreo of woll required to be I hour sholl be eliminoled . Agoin, lhonk you for your help with oddressing on unusuol sifuofion, ensuring lhe project's code complionce, yef helping lo keep the proiect moving forword. lf you need further informoiion or hove ony questions, pleose contoct me ol your eorliesf convenience. Sincerelv.a'f ^,i-./**a1 a-,,4 Soundro Spoeh, AIA cc; Mr. Chorles Dill Sortlond Conlrocfon, Inc. POST OFFTCE BOX 454 VA|L COLORADO 81658 970 476 8996 SAUNDRA LEE SPAEH AIA ARCHITECT PROFESSIONAT CORPORATION Mov 17, 2005 Mr. Chris Gunion LC.C. Plons Exominer Town of Voil Building Sofety ond Inspeclion Services 75 South Fronfoge Rood Voil. CO 81557 Re: The Dill Deck Enclosure; Building Permit # 805{080 Deor Mr. Gunion: The following ore in response io the Building Sofely ond Inspeclion Services Plon Review Commenis: I . Included in the resubmitiol is o copy of the resubdivision from l98l . Afler meeting with Elizobelh ond Joe yesterdoy, il wos determined thot lhe subdivisions ore internol/ownenhip plol lines ond ore nol property lines os used ond defined in the lBC. The existing lriplex wos plotled ond divided into ownership ofter construction with no regord tor selbocks or roof eove overhongs. The exisling structure is essentiolly on lhe plol lines, The property is oddressed os o whole os Loi 5. I hove deleled the plot lines on the orchiieclurol sile plon, os the informolion wos misleoding. 2. See response number | . 3. See response number L 4. Crowl spoce venlilolion is newly indicofed on the Lower Floor Plon, Sheet Al ond Wesi Elevolion, Sheet A2 ploced between joisls. 5. The crowl spoce elevofion hos been coordinoled . See lhe grode revisions on the Sile Plon on Sheet lA ond Section | /A2. 6. Existing smoke detectors ore inslolled throughoul the existing struclure per IRC R3l3.l. One new smoke delector is to be insiolled os shown on Sheet ME], in the newly enclosed oreo, obove lhe door '12" below the ceiling. 7. tl is my understonding thoi construction/demolition thot does noi disiurb more lhon 160 sq. fl. of oreo of exisling surfoces does nol require on osbestos lesl nor reporl. The demolilion required for the complelion of lhis project involves removing the exterior foiling deck ond removing the exisling 7'-0'' gloss sliding door leoding to the deck. The opening for the new 5'4" wide pockef door will be l0'{" wide dislurlcing only on oreo 3' by 6'€'' of drywoll, i.e.;21 sq. ft. Atloched ore two revised sets of slomped plons reflecting lhe chonges outlined obove ond o copy of lhe resubdivision olot from 198 . . lf you need further informotion or hove ony questions, pleose contocl me ol your eorliesl convenience. cc; Mr. Chorles Dill Sortlqnd Conlroclon. Inc. POST OFFICE BOX 454 VArt COLORADO 8t658 ?70 476 8996 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEYELOPMENT 75 S.FRONTAGEROAD VAIL, CO 81657 nM79-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT MF BTJILD PERMIT Permit #: BO5-OO8O Iob Address.: 1451 LIONS RJDGE LP VAIL Status.....: ISSUBD Location......: RIDGE AT VAIL TH, UNIT C Afplied...: 05l03l2n5 Parcel No....: 2l03l2ll000.3 Issued ...: 06l0ll2ffis Project No...: Expires...: lLl28l2ffi5 ol{NER DITJIJ, CmRLES A. 05/03/2005 807 S WARSOII ST LOUIS MO 63L24 APPIJICAIiIT SORTIJAT{D CON'IRACTORS 05/03/2005 Phone: 970-904-1001 P O BOX 4252 VAII,co 816s8 Lricense:348-B cor.lTRAcToR soRTr,Al[D CoNTRACTORS 05/03/2005 phone: 970-904-1001 P O BOX 4252 VAII-, co 81558 License: 348-B Descipion: STUDY ADDITION TO TOWNHOME UNIT C Occupancy: R-3 T1rye Construction: V-B Type Occupancy: ?? Valuation: $39,000.00 Fireplaco Information: Resfiicted: Y Add Sq Fc 189 # ofcss Appliances: 0 # ofGu logs: 0 #of $rood Pellet: 0 $0 ,00 Paymen6--------- > $938 . s? Building--- > $532 .55 Rcs0nrant Plan Revicw-> FEE SUMMARY s0, o0 Toal calculated Fees- > s938.57 Plan Check-- > 5346 .22 DRB Fee-------------- > S0 . 00 Additional Fee.s----- > t0. 00 Investigation- > 9o.oo Re6eation Fee---------- > $56,?0 Total Permit Fee----- > S938.57 Will Call--- >93.00 Clean-upDeposit-----> ;ilffi;;-'*r**:i*,.r+**+ai--'--""TPI*P'T;;;;;;;"*******"*.*..*i3i,9,;:l-,**-:-11'S-cI-?S;;;;;;i--'--"******'***l*;3L*'*"**** Item: 05100 BITIL,DING DEPARTI{EIII 05/L2/2o05 caunion Action: CR conment letter aent . see F : \cdev\cHRrs\PERl.rrr. coMMEl[Ts\Bos - 008 0 . Doc o5/23/2oo5 cgunion Action: CR aecond comtrentletter sent . F : \ cdew\ crn: s \ PERMTT . CoMMENTS \80 5 - 0 0 8 0 secondcheck . Doc 05/27/2005 cAunion Action: colvD t hour wall required within 3' of property Line. see ligt of conditions attached to plans. Item: 05400 PITAIINING DBPARIT.TENT 05/04/2oos ee Action: AP PAGE 2 **t**'**'**'t|.'i*!*'t**,*l.'|*|*:}***!t**'t't*'l*'t*t}*:}*'t|''tl.'t*{.*************,s'*'l*'t*'}**!t**:|t{.'+{.!t|t!*'**** CONDITIONS OF APPROVAL Permit #: 805-0080 as of 0601-2005 Status: ISSIJED *l.**:*************{.*tl't't't******'t*!t'['t:t{.lt|t*!i't'i'**'**'t**************'!*+'t*'i***:t**!t'****:t*'**'**'**'**'*!t'}***'**'N.'N.!***** Permit Type: ADD/ALT MF BIJILD PERMIT Applicane SORTLAND CONTRACTORS 97G,904-1001 Job Address: 1451 LIONS RJDGE LP VAIL Location: RIDGE AT VAIL TH, UNIT C Parcel No: 210312110003 Description: STI'DY ADDITION TO TOWNHOME UNIT C Conditions: Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALIJ,CEILINGS,AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cord: 16 (BLDG.): SMOKE DETECTORS ARE REQUIRED IN ALL BEDROOMS AND EVERY STORY AS PER SEC.310.9.1 OF THE 1997I.JBC. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQT'IRED BEFORE ANY WORK CAN BE STARTED. Cord: CON0007136 rl,c REQUIRED PRIOR TO FRAMING TO SHOW LOCATION OF ADJACENT PROPERTY LINE AND TTIE ADDITION. ALL PART OF THE ADDITION WITHIN 3' OF PL REQURE I HOLJR CONSTRUCTION WITH NO OPENINGS PERIRC. Applied: 0510312W5 Issued: 06101120[5 To Expire: lll28l20fl5 ItEM: O55OO FIRE DEPARI'I{EI{T 05/04/2005 ,tirR Action: Ap Item: 05500 PITBIJIC I{ORKS l***.**'**|*|*|'*|.r|.**l|'l|.|.t|1*'|.|*.l|||||***.***a|||t||'t*|tl|t..t*.|i**|*****t|t***|*'t|***.'+|il|.|t*l|i*|l|l**| See page 2 of this Document for any conditions that may apply to this perrrit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, cornpleted an accurate plot plan, and stat€ that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordirunces and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code ard other ordinances of the Town applicable thereto. REQITESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 4792149 OR AT OUR OFFICE FROM 8:00 AM - 4 TOWNOFVAIL. COLORADO StsatemenE Nudber: Paltment Melhod: R050000?16 Amount: Check Stat€ment 9938.s7 06 / Ot/2OO5L0 :25 AtrtInit,: IrTNotation: Sortland Cont.ractorB / ck 4LBL $938 . s7 +++ft"t*+****+**+***+*tti*+++++++***********t***aa**aa********t++l++******t*t*+++++f+f******** ACCOI,JNT ITEM LIST: Account, Code Deacription Current PnEa Permit, No: Parcel No: Site AddreEs: IJocat,ion: Thie Payment: BP 00100003111100 PF 00100003112300 RF 11100003112700 wc 00100003112800 805-0080 Type3 ADD,/Ar.,T MF BUrLD PERMTT 2103-121-1000-3 1451 I,IONS RIDGE IJP VAIIJ RIDGE AT VAIL TH, I'NIT C TotaL Fees: Total AIJL Pmte : Balance: BUIIJDING PERMIT FEES PI'AI{ CHECK FEES RECRE,ATION FEES WILI, CAI,I, INSPECTION FEE $938. s7 $938. s7 $o. oo 532.65 346.22 56. ?0 3 .00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSTG FGI CONTRACTOR INFORMATION COMPLETE VALUATIONS FOR BUILDING PER Project #:as\0v/ i{ii!?.!iift'J,# PPLICATION ing, mechanical, etc.! T0WN1FUt 75 S. Frontage Rd. Vail, Colorado 81657 General Contractoi own of Vail Reg. No.:Contact and Phone flb: MIT bor & Materials BUILpTNG:$ 31, O.rA ELECTRTCAL:$ /&o<>o _OTHER: $ PLUMBING: $ .---MECHANTCAL, S 6f 6"*.r*" . -TOTAL: $ ?? l.rzlla\ .-\> /.r-?\.(-. For Parcel # Contact E Ie Coun Assessors Office at 910-329-g640 or visit www.e /. rt'f****************i**+*i***********r**FoR oFFlcE usE o N Ly************************************** ( J lo3iTtlCrderJ Job Name\ .. '{AF"onrLLffi f rA€t, t, Legal Description Filing: fti Detail{ description-f work-: -/)E<tP 2,Vt,ostl0* Work Class: New ( ) Addition ( )Repair( ) Demo ( ) Orher( ) Work Type: Interior ( ) Exterior ( ) Both ()d Does an EH.U exist at this location: yes ( ) No ( ) Typeof Bldg.: single-family ( ) TwoJamiry ( I laurtr-iamity (p commercial ( ) Restaurant ( )orher( ) No. of Existing Dwelling Units in this building: 2 No. of Accommodation Units in this buildino: ( )Wood/peilet( ) Wood Burn Wood Burninq (NOT ALLOWEDDoes a Fire Atarm Existl--yes i-ffi Does a Fire Sprinkler System gxGF--Yes t F:\usersusuther\newBLDcpERM.Do" f fL- ^.VJ + 4gg"\JU v L*P* + g- r^"",Jt z- Dr/ln n DD q t, ?nnllltuu Al'# Ao$ Lwr Department of Community Development 75 South Frontage Road Yail, Colorado 81657 970-479-2138 FAX 970-479-2452 www.vailgoucom March 4, 2005 Ms. Sandra Spaeh, AIA PO Box 454 Vail, CO 81658 (fax) 970.476.1086 Re: 1460 Ridge Lane, Unit C Lot 5F, Ridge at Vail DRB0500s7 Dear Ms. Spaeh, Thank you for submitting an application for design review of a deck enclosure at the above-referenced address. I have staff approved the application on two conditions: 1. All disturbed landscaping shall be replaced according to a specific landscaping plan tci be submitted prior to the applicant's request for Temporary Certificate of Occupancy. 2. All materials shall match existing. Per our conversation, the Ridge at Vail was platted to allow lor 12,500 square feet of GRFA on Lot 5. I calcutated both the original plans and the plans which you submitted for review. lt appears that the total Gross Residential Floor Area (GRFA) currently in existence at Unit C is 2,562 square feet. After 131 .77 square feet of additional lloor area is constructed as part of this 250 addition request, the total square lootage ol Unit C will be 2,693.77 square feet. The site coverage increase that will result from this addition must not resuh in a total net footage of over 20olo of the entirety ol Lot 5, which I have now verified. Lot 5 consists of 'l .2957 acres (56,440 square feet). Therelore the twenty percent site coverage amount allotted to all six units is 11,288 square leet. The site coverage amount occupied by all six units today is 10,315 square feet, not including the 131.77 additional square leet that will result from this approval. The total site coverage at the Ridge (Lot 5) will remain around 18.5% after the addition. patience as these details were finalized. I wish you all the best in your volunteering etforts of weeks. Please don't hesitate to call with any remaining questions or concerns. 970.479.2454 enclosure: Design Review Action Form {p *,.".",o rtn* ,r-m Design Review Board ACTION FORM Deparbnent of Community D€ dopment 75 South Frontage Road, Vail, Colorado 81657 tel : 970,479.2139 faxz 97 0.479.2452 web: www,ci.vail.co.us Project Name: DILL DECK ENCLOSURE DRB Number: DRB050057 Project Desctiption: Deck enclosure resulting in 131.77 additional square feet of GRFA at Unit C, as part of 250 addition request; all materials to makh oristing and detailed landscaping plan to be submitted prior to TCO Participants: OWNER DILL, CHARLES A. 02/2112005 Phone; 807 S WARSON ST LOUIS MO 63124 License: APPUCANT SAUNDRA SPAEH, AIA 0A2U2CF5 Phone: 476-8996 PO BOX454 VAIL co 81658 License: Prolect Addrcss: 1451 ru RIDGE LP VAIL Location: RIDGE AT VAILTH, UNIT C Legal DescripHon: lot: 5{ Bloclc Subdivision: RIDGE AT VAIL TOWNHOMES Parcel Number: 210312110003 Comments: seeconditions BOARD/5fAFF ACTIOI{ Motion By: Actionl SIAFFAPR Second By: ' Vote: DateofApproval: 03/04/2005 Gonditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond:0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building perconnel prior to construction activities. Cond: 201 DRB approval shall not become valid for 20 days following the date of approval. Cond: 202 Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligenUy pursued toward completion. Cond: CON0006959 applicant shall match all new rnaterials to existing rnaterials Entry: 03/04/2005 By: ee Action: AP Cond: CON0006960 Prior to request fior Temporary Certificate of Occupancy, the applicant shall submit a landscaping plan to the Community Development Department to be approved as part of this appl'rcation Enry: 03/04/2005 By: ee Action: AP Planner: Elisabeth Eckel DRB Fee Paid: $3(X!.OO ll Questions? Call the Building Team at 479-2t28 Department of Community Development Project Name:) r,. )yqz Dlaa,.l,<ax - Project Address: l{-rt,- f-l\ft t- tat T-Q. t/ ' + / This Checklist must be completed before a Buildins Permit application is accepted. u. All pages of application is complete d- Has DRB approval obtained (if required) Provide a copy of approval form sz Condominium Association letter of approval attached if project is a Multi-Family complex O Plan Check Fee required at submittal for projects valued over $25000.00 (See attached Construction Fee Schedule for calculations) d-Complete site plan submitted u Public Way Permit application included if applicable (refer to Public Works checklist) Er Staging plan included (refer to Public Works checklist) No dumoster.oarkinq or material storaqe o Asbestos test and results submitted if demolition is occurrinq ,.J Er Architect stamp and signature (All Commercial and Multi family w'full floor plans including building sections and elevations(4 sets of plans for SFR and Duplex, 5 sets of plans for Multi-Family and Commercial Buildings) E- Window and door schedule {outtstructural plans, including design criteria (i.e.loads) d- Structural Engineer stamp and signature on structural plans (All Commercial and MulU Family) o Soils Repoft must be.submitted prior to footing inspection ^ { Fire resistive assemblies specified and penetrations indicated d Smoke detectors shown on olans o Types and quantity of fireplaces shown ) I have read and understa the a bmitta uirements: Applicant's Signature: Date of submittal: f rUserlUSutnennewBLDGPERM.Doc I0l,t'Ar0f l,Alt Received By: 07 t28t2044 tl BUILDING PERMIT ISSUANCE TIME FRAME If this permit requires a Tswn of Vail Fire Department Approval, Engineer's (Public Works) review and approval, a Planning Department review or Health Department review, and a review by the Building Department, the estimated time for a total review will take as long as three (3) weeks. All commercial (large or small) and all multi-family permits will have to follow the above mentioned maximum requirements. Residential and small projects should take a lesser amount of time. However, if residential or smaller projects impact the various above mentioned departments with regard to necessary review, these projects may take five (5) weeks to review and approve. Every attempt will be made by this department to expedite this permit as soon as possible. I, the undersigned, understand the plan check procedure and time frame. I also understand that if the permit is not picked up by the expiration date, that I must still pay the plan check fee and that if I fail to do so it may affect future permits that I apply for. Agreed to by: Print name Signature Project Name: Date: F:\Users\JSuther\newBLDGPERM.DOC 07 t281?004 II PUBLN WORKS AND THE PUBLE WAY PERMIT PROCESS Horv it relates to Building Permits: Fill out the atbched check list with the Buildinq Permit Application' If yes was answered to any of the quesflons then a Yublic Way" permit is required, You can pick up an application at either Community Development, locabd at 75 Soutt Frontage Road or Public.Works, locaEd at 1309 Elkhorn Drive. Notice sign-offs for utility companies. ALL utilities must field verifo (locate) 'respectlve utilities prior to signing application. Some utility companies require up to 48 hours notice b schedule a locaE. A construction traffic control/staging plan must be prepared on a separate sheet of paper. An approved site plan may also be used, This plan will show locations of all traffic control devices (signs, cones, etc.) and $te work zone, (area of construction, sbging, eb'). This plan will expire on November 1st and will need to be resubmitted for consideration for approval trrough he winter. Be aware hat your resubmission for winter may be denied depending on the location of construction. Skebh of work being performed must be submifted indicating dimensions (length, width and depth of work). This may be drawn on he traffic control plan or a site plan for the job' Submit completed application to the Public Work's office for review. If required, locabs will be scheduled for he Town of Vail electricians and irrigation crew. The locates take place in the moming, but may require up to 48 hours to perform. The Public Work's Construction Inspector will review the application and approve or deny the permil You will be conbc@d as to he status and any requirements that may be needed, Most permib are released within 48 hours of being received, but please allow up to one (1) week to process. As soon as the permit is approved, tre Buibing Deparlrnent will be notified, allowing the "Building Permit" to be released. Please do not confuse the'Public Way Permit" with a "Building Permit". NOTE: The above process is for r,vork in a public way QNLY. Public way Permits are valid only until November 15th. A new Public Way Permit is required each year if vnork is not complete. Re-application each ltlovember 15th doep not mean an aubmatic renewal. r ' tkzt - 6.r__ tand above. Date Signed 07 tz8t?oo4 tl PRJ #: APPLICATION PW #: FOR TOWN OF VAIL Parcel #: PUBLIC WAY PERMIT 20 Blde. Permit #: B - TO['NM , 1. .) Job Name Street Address ( llF unknown callz. 47q-? | la\ Excavating Contractor Nanre Mail Address "l'OV Conlroclor Liceuse Number - REQU ll{EI) State l'hone # Stan Date Completion Date (Permit Expiration Date) 4. Work is for (circle one) Water Sewer Gas Eleclric Telephone CATV Landscaping Temp. Site Access Other 5. Trench-width Length Depth zipCit-v J. (min.4') Bond Amount $Permit Fee $ Total SF $ Toral LF Total Permit Fee $ 6. ALL MATERIAL, EQUIPMENT, AND TMFFIC CONTROL DEVICES MUST BE ON THE JOBSITE BEFORE THE JOB IS STARTED. 7. Rubber out-riggers are required on excavating equipment when working on asphalt. Asphalt surfaces underneath the bucket and lugs shall be protected at all 1imes. 8. A signature below indicates a review ofthe area and utility locations and approval. Once all utility company signatures are obtained , permittce has option ofrouting application through the Public Work office to obtain the necessary Town of Vail signatures. Please allow up to one week to process. Xcel Energy / Public Service Company ( I -800-922-1987) Xcel Energy High Pressure (1-800-922- 1987) Quest ( l -800-922-l987) Comcast Cable ( I -800-922-1987) Eagle River Water & Sanitation District (970-476-7480, ext. I l4) Holy Cross Electric Company ( I -800-922- 1987) Torvn of Vail Electricians (970-479-2158) Town of Vail Irrigation (970-479-2158) THERE WILL BE NO TOTAL STREET CLOSURESI A c.onstruclion lraffic control plan must be submitlcd and approved by the Public Works Departnrenl prior to isruarrce ofthe perrnit. 9. All excavation nrust be done by hand within 18" ofutilities - (Senate Bill 172). forfeiture of bond money. Scheduled inspections that are not ready may result in the Town charging the contractor a reinspection fee. 11. lcertiJythat I have read all chapters ofTitle 8 -Public Ways and Property, of theVail Municipal Codeandall utility Company agreements, signed by me, and will abide by the same, and that all utilities have been notified as required. C'onfuirc:lol's Sisrral.ulc of.,\grcenlent Print natnct clearly Date of signatule ATTACII PLAN OF WORK, INCLUDINC CONSTRUCTION TRAFFTC CONTROL PLAN White - Public Works Shorv street rvith narnes, buildings, and locarion of cuts. USE DASU LINES FOR CUT. Yellow - Contractor F:\Users\JSuther\newBLDGPERN4. DOC o7 t28t2004 tl WHEN A *PUBLT WAY PERMIT" IS REQUIRED PLTASE READ AND CHECK OFF EACH OF THE FOLLOW]NG QUESTIONS REGARD]NG THE NEED FOR A "PUBLIC WAY PERMIT": o Is this a new residence? YES NO ./' tr o n o Is any dminage work bejng done that affecE he Right-of-Way, easemenB, or public property? YES 'NO ,/. tl r Is a "Revocable Right-of-Way Permit" required? YES NO /' Is the Right-of-Way, easemenb or public property to be used for sbging, parking or fencing? YES NO ,./ f.TtT, o ^Rb,t tjgrt'rg, sbging or fencing plan required by Public works? If you answered YES to any of these questions, a "P ublic Way Permit" must be obtained. "Public Way Permit" applications may be obbined at the Public Work's office or at Community Development (a sample is atlached). If you have any questions please call Leonard Sandoval in Public Works at 479-2198. . Does demolition work being performed require the use of the Right-of-Way, easemenE or public property?YEs_ No / Is any utility work needed? YES- NO ./' Are frere any improvemenE being done to the driveway ? YES NO /' Is a different access needed to the site ofrer than the existing driveway? YES- NO-Z Contractor S ignqture Job or project r,rur"' b lcl JecZ &l c: -'--G-Bt-.rt-l., tr <, -f*oarnl ,^r. Date Signed: FlUsers\JSuther\newBLDGPERM.DOC F' /6r,an,^^6 /f^.6c /hl.l^6rm4 07 t28t2004 tl DRAINAGE AND CULVERT INSPECTIONS ARE REOUIRED BY PUBLIC WORKS! Please read and check off each of the items below: The Town of Vail Building Department has developed the following procedures to ensure that new construction sites have adequately established proper drainage from building sites along and adjacent to Town of Vail roads or streets. The Town of Vail Public Works Depaftment will be required to inspect and approve drainage adjacent to Town of Vail roads or streets and the installation of temporary or permanent culvefts at access points from the road or street onto the construction site. Such approval must be obtained prior to any requests for inspection by the Town of Vail Building Department for footings, temporary electrical or any other inspection. Please call Leonard Sandoval at 479-2198 to request an inspection from the Public Works Department. Allow a minimum of 24 hour notice. Also, the Town of Vail Public Works Department will be approving all final drainage and culveft installation with resulting road patching as necessary. Such approval musL be obtained prior to any Final Certificate of Occupancy issuance. Agreed to by: Print Name Signature Project Name: Date Signed: F:\Users\JSuther\neTvBLDGPERM.DOC 07128t2004 MATERtrAL STORAGE AND CONSTRUCTION PARKING Please read and check off each of the items below. (Copies of complete text are available upon request) CODE 5-2-10: DEPOSIIS ON PUBLI WAYS PROHIBTTED o Unlawful deposits: Subject to subsecb'on C frereof, it is unlawful for any person to litter, track or deposit or cause to be littered, tracked or deposited, sand, gravel, rocks, mud, dift, snow, ice, or any other debris or material upon any stree! sidewalk, alley or public place, or any portion thereof. q Notice; Abatement: The Director of Public Worla may notifo and require any person who violates or causes anober b violate the provision of subsection A hereof, or who has in the Director's employment a pe6on who violabs or causes another to violate the same, top remove such sand, gravel, rock, mud, dirt,.snow, ice or any ofrer debris or material within twenty four (24) hours after receipt of said notice by Sre Director of Public Works. In the event the person so notified does not comply with the notice within the period of time herein specified, he Director of Public Works, or oher auhorized agent, may cause any such sand, gravel, rocks, mud, dirt, snow, ice, debris or any other material to be removed from any street or alley at the expense of the notified. o Summons and Penalty: As an alternative to the notice for removal provided in subsection B above, any person who violates or causes another to violate fie same, may be issued a summons to appear before fie Municipal Court of the Town for said violations, and upon being found guilty of a violation hereunder be punished as provided in Section 14"1 of this code. o Notice and Penalty: It is unlawful for any person to fail or refuse to comply with the notice of the Director of Public Works as provided in subsection B hereof, and any such person shall, in addition to payment of the expense of removal incurred by tre Director of Public Works, as provided in subsection B hereof, upon being found guilty of a violation hereunder, be punishable as provided in Section 1-4-1 of this Code. (1997Code: Ordinance 6 (1979). CODES 7-3A-L AND 7-3A-3: PARKING OBSTRUCTING TRAFFE & IMPOUNDMENT AUTHORIZED o No person shall park any vehicle upon a street or at any other place within this Municipality in such a manner or under such conditions as to interfere with the free movement of vehicular traffic or proper sb'eet or highway maintenance. (Ord. 2(1968) 5 1) o Whenever any police officer finds a vehicle attended or unattended, sbnding upon any poftion of a sbeet or upon any place within this Municipality in such a manner as to constitute a violation of any section of this Article, or left unattended for a period of twen$ four (2a) hours or more and presumed to be abandoned under tre conditions prescribed by Colorado Revised Sbtutes section 424-1102, as amended, the officer shall require the vehicle to be removed or cause it to be removed and placed in storage in the nearest garage or ofrer place of safety designated or mainbined by ttis Municipality, and the charges for towing and storage of such vehicle shall be charged to the owner of he vehicle in additjon to a ten dollar ($10) impoundment charge. (Ord. 2(1968) 5 3:0rd. 28(1981) $ 1) I have read and will comply with the above code provisions: '.1 zJ e position or Relarionship ro project: /PU}{ ) . t'*no'"t' f D$Beiigsrdheirew9tDqeEE!4.lDQlt _07 t?8t2004 ll Town of Vail Survey Community Development Department Russell Forrbst, Director, (970)47s-213s Check all that aoplvDate: t/-2 6':67 1. Which Department(s) did you contact? Building_ Environmental_Housing_Admin_Planning_DRB - PEC_ 2. Was your initial contact with our staff immediate ,/ slow- or no one available-? 3. lf you were required to wait, how long was it before you were helped? tU o 4. Was your project reviewed on a timely basis? Yes/No lf no, why not? 5. Was this your first time to file a DRB app PEC app- Bldg Permit N/A 6. Please rate the performance of the staff person who assisted you: 5 4 3 21 (5 is high) Name: responsiveness, availability) 7. Overall effectiveness of the Front Service Counter. 5 4 3 21 (5 is high) 8. What is the best time of day for you to use the Front Service Counter? 8. What comments do you have which would allow us to better serve you next time? Thank you for taking the time to complete this survey. We are committed to improving our service. (knowledge, F:\UsersUSutheAnewBLDGPERM.DOC 07 t2812004 uzfLLtvo lt:Io .tAI oI{ JZI oldto CAD/rnac Enclosurcs UAItsI'AI ADSUUI.AIIJD Charles A. Dill 807 South Warson Road St. Louis, Missouri 63124 February 10,2005 Best regards, Charles A- Dill sluuo To: Ridge at Vail Homeowners Dear Neighbor: As you will note from the enclosed copy of my letter to my nent-door neighbor' John Hartwig, I am proposing to convsrt my back deck into a study room adjacent to our dining area. John has reviewed my proposat, together with prcliminary drawings, and agreed that this renovatim is acceptabte. ft4y tJ-iit"l is to secure the required buitdi"s ryryryT,* Towu of Vail. Vail requires the approval of tbe project by ^our Uondonuruun Association. Accordingly, ii."*paUf" to you, I would appreciate rf you would €xccute the enclosed fonn and t.tu- iito'ry attenion in the enviiope provided at your earliest convenience. Once this pmject is completed, I would be happy to sbare with you tht Plry: cotrfractor n" "r, .ortr,-"tc., shouli you iecide in t1c firn'e to convert your back deck hto a room as I am proposing. Thank you for your help on this project. Mr. Charles A. Dill 807 SouthWarsonRoad St Louis, Missouri 63124 Dcar Charlie: Condomiuium Associatiou Approval I harre rcvicwed your proposat to convert your back deck into a root& ard agree with this project. JamesFlrum Date I]?lt?(x Date f)ate -2 - | 5 -oS' .Date \1 ,t&c.-rsr-xs(sn.9Pev oerrr a/ 5 Marlene Kcanreye-,?!rG,a Fn-gS. 4,, Piergio.rgio Gosta Darc Depfunent of Community hvelopment Building Safety and Inspection Seruices 75 South Frontage Road Vail, Colorado 81557 970479-2138 FAX 9704n-2452 www.uailgov.com BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO:Contractor/Aoolicant Sortland Contractors FAX/Email#: none given NUMBEROF PAGES: 2 FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: Architect Sandra Spaeh proj#401 none given Chris Gunion, Building Plans Examiner oslL2l200s 805-0080 Dill 1451 Ridge Lane unit C R-3 V-B existing addition The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003International FuelGas Code, 2003International Plumbing Code and 2002 National Electrical Code as modified and adopted by the Town of Vail. The following @mmenB will nd to be addrcsd prtor to issuane of a building permit: For processing: e Please submit two comolete sets of revised construction documents containing the reouested information with all olan revision items clouded or otheruvise identified. o Please respond in writing to each comment by marking the attached list or creatinq a response letter. Indicate which olan sheet. detail. soecification. or calculation shows the requested information. Please send revisions to the attention of the olans examiner with the building permit application number noted. o Please be sure to include on the resubmittal the enqineer's or architect's "wet" stamp. signature, registration number and date on the cover page of anv structural calculations, all structural details and structural sheets of the olans. For commercial or multi-familv oroiects all sheets of the olans must be stamoed. Architectural Com ments: 1 Amend site plan and floor plans to clearly show dimensions to the adjacent south property line. Include the condominium or townhome map showing locations of any other property lines between units. 2 Exterior walls of R-3/U-1 occupancies are required to be one hour fire resistive construction when located less than 3' from property line. Revise plans. Provide a UL or gypsum association listing for the t hour wall assembly. Overhangs are not permitted to extend closer than 2'to the property line and shall be protected by t hour construction on the underside where within the fire separation distance. (R302) 3 Openings are not permitted in exterior walls of R-3/U-1 occupancies are not permitted less than 3' from property line. (R302) 4 Show method of crawl space ventilation. (R408) 5 Coordinate crawl space finish grade with 1/A2 section, structural plans and Town of Vail Planning Department. Structural plans show top of footing al89'-L0 1/2". 6 Smoke detectors are required to be installed throughout the existing dwelling unit per IRC R313.1 7 Asbestos test and report is required for all remodel/addition projecls per TOV ordinance. Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permig please check nll rcquested information is included with the rcsubmitted plans, Please submit revised plans as a complete s€L Partia! plan resubmittals will not be reviewed. Chris Gunion I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Seruices 970.479.2369 caunion@vailgov.com F:\cdev\CHRIS\PERMIT.COMMENTS\805-0080.DOC