HomeMy WebLinkAboutVail Village Filing 2 Lot E & F (15) I`I tII`I1ti��1�11�1R11���1 4 . - 0 2 3 H I S R E I� GENERAL NOTES: 2 1, COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER AND WITH GE 1 MEDICAL SYSTEMS INSTALLATION DRAWINGS PRIOR TO ROUGH—INS, 2 2. ALL CONDUIT AND DUCT RUNS SHALL HAVE LONG SWEEP BENDS. �— 3. CONDUITS AND DUCT INSTALLED ABOVE CEILING OR BELOW FLOOR I -- - - 0__ - I I MUST BE INSTALLED AS NEAR TO CEILING OR FLOOR AS POSSIBLE I I I i TO REDUCE RUN LENGTH, CONSTRUCTION MANAGER 4. ALL DUCTWORK SHALL BE CERTIFIED/RATED FOR ELECTRICAL POWER The HCBeck Group PURPOSES AND SHALL BE ELECTRICALLY AND MECHANICALLY PO BOX 8529 BONDED TOGETHER IN AN APPROVED MANNER, Avon, Colorado 81620 I I I I I (TYR. I I I n I, 6. ALL WIRES SPECIFIED SHALL BE STRANDED, FLEXIBLE, THHN/THWN, ---I- --- °_ I I I I COLOR—CODED, COPPER ONLY, CUT 10'-0" LONG AT OUTLET BOXES, I - PT = _ °_ 4 DUCT TERMINATION POINTS OR STUBBED CONDUIT ENDS, UNLESS OTHERWISE NOTED. ALL CONDUCTORS, POWER, SIGNAL AND GROUND, MUST BE RUN IN CONDUIT OR DUCT SYSTEM. RING OUT AND TAG DAVIS PARTNERSHIP ARCHITECTS ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BE CONTINUOUS AND 0225 MAIN STREET . UNITC 10 1 E . COLORADO 81632 LLJ FREE FROM SPLICES, 970.926.8960 F.970.926.8961 L I __ _� ^_ I — m 7. ROUTING OF CABLE DUCTWORK, CONDUITS, ETC., OTHER THAN SHOWN ON THIS DRAWING MAY RESULT IN THE NEED FOR GREATER 6 9 ! r XRL1 THAN STANDARD CABLE LENGTHS (REFER TO GE MEDICAL SYSTEMS DRAWINGS FOR MAXIMUM USABLE LENGTHS POINT TO POINT. I I I ISSVEIREVISION DATE NO. FOR PERMIT 12/12/03 I I +54" ADDENDUM #1 3/16/04 u 1 �I 3 1. EXISTING PANEL "PG—DHM" IS LOCATED IN THE EAST MAIN (D TO ROOM, REFER TO "SECOND FLOOR KEY PLAN", THIS TO "PG—DHM" SHEET FOR ROOM LOCATION. 2. REMOVE EXISTING WARNING LIGHT. PROTECT EXISTING 120V BRANCH - CIRCUIT FOR REUSE UNDER NEW WORK, REFER TO "X—RAY ROOM NORTH v I EwG DARK RM POWER AND SYSTEMS PLAN", THIS SHEET, FOR MORE INFORMATION. X-EAY ROOM LIGHTING PLAN, 3. NEW WARNING LIGHT. CONNECT TO EXISTING 120V BRANCH CIRCUIT, SCALE, 1/4" 1'-0" 4' fl 4' g' 4. PROVIDE 11" SQUARE, RECESSED INCANDESCENT DOWNLIGHTS WITH NORTH TEMPERED PRISMATIC LENS AND REGRESSED WHITE DOOR, LITHONIA 1 #LA-1IRW—T73, OR ENGINEER—APPROVED EQUAL. PROVIDE (1) 100W A-19 LAMP FOR EACH LUMINAIRE. 1 SCALE; 1/4* = 1`-0" - 4' 0 4 8' 5. NOT USED. ' REG, P 6, PROVIDE 150OW, 'WHITE, SLIDE—TO—OFF DIMMER SWITCH, LUTRON *•c •o Hfwe• DINT-1500—WH, OR ENGINEER—APPROVED EQUAL. 727 7, REMOVE EXISTING SMOKE DETECTOR AND REINSTALL ON NEW CEILING, 0 EXTEND EXISTING FIRE ALARM CIRCUITRY AS NECESSARY. be .� - $. REMOVE EXISTING LUMINAIRE. PROTECT EXISTING 120V NORMAL AL ELECTRICAL LEGEND LIGHTING BRANCH CIRCUIT ORIGINATING FROM PANEL "L1A" LOCATED IN CORRIDOR APPROXIMATELY 75' WEST OF THE X—RAY ROOM. DESCRIPTION LE TRI A H 9. CONNECT TO EXISTING LOCAL 120V NORMAL LIGHTING BRANCH WIREWAY ® ESC ION 1 RDWAR CIRCUIT ORIGINATING FROM PANEL 11A", PRIOR TO NEW WORK, VERIFY WITH AMMETER THAT THE BRANCH CIRCUIT DOES NOT A MAIN DISCONNECT PROVIDE NEW 70A3P, 48OV, 30, RECESSED, ENCLOSED CIRCUIT BREAKER PANEL WITH AUTO EXCEED 6.0 AMPERES WITH ALL LOADS SWITCHED ON. RESTART FEATURE, GEMS #E4502HY. I - _- -- , �.�..� I ' I DLK1 DOOR SWITCH PROVIDE NORMALLY OPEN 24V DC SAFETY DOOR INTERLOCK LIMIT SWITCH, THE ROOM DOOR SHALL I I BE CLOSED TO ALLOW X—RAY OPERATION. MOUNT +6'-6" AFF TO CENTER. J I z W r K CASSETTE HOLDER PROVIDE 6 0X6"X4" DEEP PULLBOX WITH 11-1/2" DIAMETER CHASE NIPPLE AND COVERPLATE. MOUNT FLUSH IN WALL +2'-3" AFF TO CENTER. W Q LO I I O OC CONTROL CONSOLE PROVIDE 6"X6"X4" DEEP PULLBOX WITH 2-1/2" DIAMETER CHASE NIPPLE AND COVERPLATE. MOUNT �I I - -- --- -- - -�I FLUSH IN WALL +1'-6" AFF TO CENTER. w © ;; I{ PT TABLE PROVIDE (2) 1-1/4" DIAMETER SHORT NIPPLES WITH BUSHINGS AND LOCKNUTS. 41 �Y / \ t - - - - a — I � `��' 7 -` �`s_L XG GENERATOR PROVIDE 32" OF GROMMET MATERIAL FOR AN $"X8" OPENING IN DUCT COVER. PROVIDE 6'-0" OF 3: 0 cu I 1 1-1/2" FLEXIBLE METAL CONDUIT, AND (2) 1-1/2" 90 DEGREE CONNECTORS. 0 M X—RAY W O �°� I XRLI WARNING LIGHT PROVIDE PRESCOLITE #EX1R "X—RAY ON" INCANDESCENT LUMINAIRE, OR ENGINEER—APPROVED EQUAL. ROOM w 1 24V, $A OR LESS LOW VOLTAGE SOURCE. MOUNT 6" ABOVE DOOR. O PROVIDE WARNING LIGHT CONTROLLER, GEMS4500AM, AND INSTALL_ PER GEMS DRAWINGS.00, AL CD j XTS1 X—RAY TUBE HANGER " " BE GE PROVIDE 32 4F GROMMET MATERIAL FOR AN $ X$ OPENING IN, DUCT COVER. w w L) 2 �/ I - SWD-1 SURFACE WALL DUCT PROVIDE 10"X3-1/2" SURFACE WALL DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE GONERS. .J I U SURFACE MOUNT +0'-9" AFF TO CENTER. o x u SWD-2 SURFACE WALL DUCT i PROVIDE 10-X3-1/2* SURFACE WALL DUCT WITH DIVIDERS AND REMOVABLE, / � » ACCESSIBLE COVERS. _ J J SURFACE MOUNT FROM FINISHED FLOOR TO +1 —0 ABOVE FINISHED CEILING. - SWD-3 SURFACE WALL DUCT EXISTING 4X4» SURFACE WALL DUCT. J u, cu �+:5 1 TD TRENCH DUCT PROVIDE 12"X3" TRENCH DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS, NORTH Q a ` MOUNT FLUSH IN FLOOR. a' +, N -> NO SCALE a- NORTH -5 SCALE; 1/4" - 1'-0" - FEEDER SCHEDULE ELECTRICAL 0 4 0 4 $ 0i WIRE AND C014DUIT SIZE EAST MAI N PLANS � 1 ELECTRICAL CD 1 2-1/2"C WITH PULLWIRE ROOM :� Offic Opy b ! f b Iii 2 (2#12+#12c)1 f 2"C DATE 12/12/2003 e U 3 (4#4+#1/OG)1-1/4"C _ b 8 DRAWN 8Y CMP �s CL L 4 (3#4+#1/0G)1-1/4"C CIiK'D BY CMP APPR—OVED r� ` - _ SHEET FILE E2',0.DWG d FOR ELEC POWER I APPEARS TO MEET THE ` e ` ` 65 . COPYRIGHT 2003 BY DAVIS PARTNERSHIP P.C., ARCHITECTS X NATIONAL ELECTRICAL CODE AS ADOPTED&AMENDED BY SHEET MINOM f> WWIN 0 -VAI By ,�� ` ` le NORTH Dale SECOND FLOOR KEY PLAN G,�✓ �l'' �C>��r v NO SCALE 7 Q.P.A. PROJECT # 03942.00 J7 r i 1 a PANEL PG-DHM EXISMG- NORMAL VOL WASE - 124D AWP: MAIN BRENaM ® um ofty 0 Ii ou Nmmr. : SUWADE w All GRpJND BUS. NEUTRAL 0 DOMIP-71ON L R A L R MINE DESCRIPTION LOAD JU G . ST. PANEL "DHA� [� u 2 M 3 4 M 5 6 PEAK LOAD REPORTED OVER LAST 12 MONTHS SPR 7 8 6P AS REPORTED BY HOLY CROSS ENERGY: 9 1` 260.0 KW (AUGUST 2003) OQFISTI9CTl0�l _ 11 12 - 305.9 KVA (O 85% PF) X 125% = 382.3 KVA COT 4 SP 13 14- SP . 15 1 DEMAND LOAD REMOVED: BE)X13� 17 78 19 20 OLD X-RAY UNIT (EST.) - 18.0 KVA X 10DX - 18.0 KVA Ate'Colorado 81620 SP SP 21 2 FROM PANEL "L1 A (LIGHTING) 0 8 KVA X 1259 = 1.0 KVA SP 2 24 sP LO�ID JUSTIFICATION F R PANEL L1 A TOTAL DEMAND LOAD REMOVED: _ 1 , 25 6 100A. 120/208V, 38. 4W DEMAND LOAD ADDED: 27 28 TO PANEL 'LPG-DHM" (X-RAY) - 48.5 KVA X 1 DOX = 48.5 KVA DAVIS PARTNERSHIP ARCHITI=M SP 29 30 Isp DEMAND LOAD REMOVED: " = 1.1 KVA X 125X = p,� TO PANEL "L1 A (LIGHTING) 1.4 KVA ��'COLORADO 8 � SP 31 32 s E.D, RENOVATION PROJECT, TOTAL DEMAND LOAD ADDED: 00 49.9 KVA 33 34 ISSUED 10-3-03. REVISED 11-7-03 - 2156 VA X 100% - 2156 VA 970.926.8960 F.970.92SM1 SP 35 36 LIGHTING - 800 VA X 125X - 1000 VA NET DEMAND LOAD ADDED: 30.9 KVA SP 37 38 SP TOTAL DEMAND LOAD REMOVED: _ VIA SP 39 40 TOTAL DEMAND LOAD: = 413.2 KVA SP 41 42 sP DEMAND LOAD ADDED: M 1 IN N UGH7ING 1100 VA X 1259 = 1375 VA TOTAL A VOLT-AMPERES A TOTAL MAIN DISIRIBU71ON PANEL CAPACITY: E LE . 48501 NET DEMAND LOAD MOVED: = 1781 VA 2000A FUSES IN MAIN DISCONNECT SWITCH 1662.8 KVA ISSUEIREVISION DATE NO. CONNECTED 1:25 CONNECTED 68.5 KVA 1171ING PT: T 10 DESIGN 997.7 KVA � 2/12/0 DPAAND 73.4 KVA 1. SPARE 9242 KVA1 3�18�If14 EST 20.0 `1. 24.9 CONNEVED : - PHASE A 22.8 KVA 5 1 - 5 PHASE B 22.8 KVA IN 1.00 PHASE C 22.8 KVA _ PHASE BALANCE Oli4ER 1.00 A TO 8 1007 WELL B 70 C 1009 is C 70 A 1008 1. NOT USED "L1A" wL1A1" TOTAL 68.5 KVA -73.4 KVA ALL CIRCUIT BREAKERS (D LOAD 1 82.3 AMPS ARE 20 AMP. 1 POLE 2. REMOVE E=71NG CIRCUIT BREAKER AND FEEDER BACK TO SOURCE. X-RAY DESIGN 1 ;0 AMPS LMII ESS NOTM 4TI#RwNSE 3. SHORT CIRCUIT VALUES BASED ON 500KVA UTILITY TRANSFORMER WITH WANE ARE 1111.7 AMPS IMPEDANCE Z=1.5X 100A L - LIGHTING R = RECEPTACLE M - MOTOR T - TRANSFORMER SP - SPACE S - SUBFEED E - EQUIPMENT A - APPLIANCE 0 = 07HE R SPR = SPARE 60A3P NO LO R . NG. P1 IMADE WX ll=l R`MERIM41 1011 101PAM TO.tiiMlIM 1001119 PANE.. Al All 'AL A w To ' 37276 • +� TO FLASH TO TO 110 TO . , "P 4 "PPPP1" "LPPD"/ ATS-2 STERILIZER 7 "MCC" ATS-3 "LPL' A7S 1 3-1(f.1) wwww,w VXK00N$Lt7N698NffKNC. 400A 1000A 600A 200A 600A 40A 10DA 10DA 100A 150A 175A 175A 300A t Jim J&4 JJI ,I,NN JJ N I € I FRN FRN FRN FRN FRN FRN FRN FRN I 400A 1200A 600A 400A 600A 60A 100A 100A 100A 100A 100A 200A 200A 200A 400A 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P I I SPACE € I SPARE SPARE I w J co DISTRIBUTION Pmm 3X " z - 120/2W 30, 4W, 3DDOA 120 20BV. 30. 4W. 10DOA (D 100.000 AIC V -� t CL j W w � NEW d Q Q� O O � X-RAY RM B 0 £a A�lu COND. ' 7oA -- 3P cu v� BL1A1" UNIT {ROOF} H A" DHLC � O 4 III cu RF M SAN 6 - 0 O ROOM 125A TO 125A 9 _ Q Dj C3 FRS-R ~PG- AMBULANCE W a 200A O BUILDING FEEDERS 10DA3P 225A3P 1200A 3 SHORT CIRCUIT SCHEDULE W s 200A LIEBERT MCB MICE 3P GR J 1 L FUSES INTERCEPTOR 250A MCB )( SHORT CIRCUIT CURRENT J I TVSS d -- d LPS 3 r 5 3P ss 400A3P 1 40,094A C3 30KVA, 45KVA, 75KVA. #2G 2 4136-3 - 208V, _ 208V. - Z0$V. _ _ 3 33,871A d I- 30,4W 30.4W 30.4W 500KVA, 4 9,156A +a' 100A HOLY CROSS 480-120/ 0 50D KVA FUSES 8 2 n. HOLY CROSS �� 208V.3lf.4W SECONDARY 1DOA 1 27AD-MOU TED 150A soA 45A A A 11 OA 125A 12 WA 7 A FEEDER SCHEDULE ONE-LINE DIAGRAM (SERVICE 2R) I t I LIPS FUSES FUSES FEU -FUSES LPOS IRS IRS FUSES I AND LOAD r� WIRE AND CONDUIT SIZE i 3000A 2000A 200A 200A 60A 1DDA 10DA 100A 200A 1OOA 200A 200A 1200A 1200A JUSTIFICATIONS vi 3 I I I IV FmS I SPACE 3P 3P 3P IV 3P 3P 3P � 3P 3P 3 I 1 6[(4-500KCMIL+#1/0G)4"C]+2(4"C) A 2 2[(3-500KCMIL+#1/OG)3•C]+4(3"C) off, _j L _ L _ L _ - - _ _ - r 3 4[(4-250KCMIL+2#2G)3-1/2"C]+ ME 12/12,/ 03 4(3-1/2-C) a 10 1 2 #4/OG TO BUILDING DIMMUT d STEEL AND COLD " " 4 3[(4--500KCMIL+#2/OG)3-1/2"C] a WATER PIPES 1 3000A. 277 48OV, 38, 4W 5 (2#1/0+#3G)1-1/2"C CWD BY CYP L = = DOKCMIL,G TO "MDG" 100,000 AIC S PARTIAL EAST NORMAL 6 ( -�'/��'-�/4"c sr�r � ao.� 7 4 2+. G)1-, 2 C d # 1 oo +r soon BY aws P.C. Arrocrs 11111111101-111111 PDXR .ME-UNE Q"AMI AP RO D 8 3[ .4=600KCMIL+#3/OG)4"C] x NO SCALE - FOR ELEC POWER APPEARS TO MEET THE g NATIONAL ELECTRICAL CODE U AS ADOPTED&AMENDED BY TOWN OF VAIL E3mO BY W 13.PIL PROJECT# 43942.00 Date ^_2 a E / PROJWT ADDRESS ALL BULDIM SHEET ; SNEEr MANE REV. >t QIgE 1_ DO NOT SCALE DRAWINGS. VAIL ALLEY MEDICAL CENTER APPL ONU BULOM ODES : ARA*IfECRDAL 2. IF DISCREPANCIES IN ARCHITECTURAL ELEMENTS (PARTITIONS, DOOR LOCATIONS... ETC) 181 MEADOW DR AO.0 GENERAL INFORMATION OCCUR BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, THE ARCHITECTURAL VAIL. COLORADO DRAWINGS SHALL GOVERN; ADVISE ARCHITECT PRIOR TO COMMENCING WORK. 1997 THE UNIFORM BUILDING CODE A1.0 DEMOLITION FLOOR AND CEILING PLAN � 1998 THE INTERNATIONAL MECHANICAL CODE A2.0 FLOOR AND CEILING PLAN 3. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME COMPLETELY FAMILIAR WITH ALL 1997 THE UNIFORM FIRE CODE A3.0 DETAILS ow %ft %%U" L23MM CEN M EXISTING CONDITIONS IN THE AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. 1994 THE UNIFORM PLUMBING CODE EDWARDS COLORADO 4. CONTRACTOR TO COORDINATE THE FOLLOWING WITH THE OWNER: PROJECT PHASING. SITE 1999 THE NATIONAL ELECTRIC CODE ACCESS, TEMPORARY UTILITIES AND OWNER INSTALLED EQUIPMENT. ELlET•I X OON'SnWCWN MMNAOER/ MK 5. THE CONTRACTOR SHALL NOTIFY THE OWNER 7 DAYS PRIOR TO COMMENCING WITH WORK. E1-0 ELECTRICAL COVER SHEET =IRA= P.O. BOX 8529 E2.0 ELECTRICAL PLANS AVON, COLORADO 81620 6_ THE CONTRACTOR SHALL KEEP PREMISES FREE FROM" ACCUMULATION OF WASTE E3.0 ONE-LINE DIAGRAM AND LOAD JUSTIFICATIONS CONTACT: TODD BERRY (303) 466-9665 MATERIALS AND DEBRIS THROUGHOUT THE ENTIRE BUILDING AREA- FAX (303) 466-9667 E4.0 ELECTRICAL SPECIFICATIONS 7- ALL INTERIOR ELEVATION DIMENSIONS ARE FINISHED DIMENSIONS, UNLESS OTHERWISE OCCUPP= TYPE AND OONSTRUCWt NOTED- CONSTRUCTION MANAGER ARCHTEICT WWIS PARrNEFAM. P.C. The HCBedc GwW OCCUPANCY CLASSIFICATION: 1-1.1 HOSPITAL tUBC TABLE 3A 0225 MAIN ST., UNIT C101 8- GENERAL CONTRACTOR IS TO COORDINATE LEAD SHIELDING REQUIREMENTS AND PO BOX 8529 EDWARDS, COLORADO 81632 SPECIFICATIONS. LEAD SHIELDING IS TO BE INCORPORATED INTO GYPSUM WALL BOARD. Avon.Calorado81620 CONTACT. SCOTT NEVIN, AIA (970) 926-8960 DOOR, DOOR FRAME, WINDOW, AND WINDOW FRAME PER SHIELDING ANALYSIS PROVIDED F TR TI N: TYPE I FIRE-R SI FAX (970) 926-8961 BY THE OWNER. 9. GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR THE FOLLOWING: O12MLIM ENONEOM 1N0C A. GYPSUM WALLBOARD ALLOWABLE FLOOR AREA: UNLIMITED UBC TABLE 5B 7350 E. PROGRESS PLACE, SUITE 100 B. LIGHTING AND ELECTRICAL DEVICES DAVISpARTNERSHIPARCHI ENGLEWOOD, CO 80111 C. DOORS. FRAMES, DOOR HARDWARE, WINDOW FRAME AND LEAD GLASS 0225 KIANV STREET.UNIT C101 ALLOWABLE HEIGHT: U `TABU MECHANICAL AND ELECTRICAL CONTACT: CRAIG PERRY (303) 721-6600 D. ALL FINISHES INCLUDING FLOORING, CEILING TILE, RUBBER BASE AND PAINT. EDWARDS,COLORADO 81632_cp _ FAX (303) 721-0200 9170.926.8980 F.970.926.8961 REFER TO ELECTRICAL FOR ADDITIONAL REQUESTED SHOP DRAWINGS. FIRE P N TI ' AUTOMATIC SPRINKLER SYSTEM C 10. GENERAL CONTRACTOR IS TO COORDINATE EQUIPMENT DELIVERY AND ACCESS. NOT PROVIDED IN REMODELED ROOM DETECTORS AND ALARM SYSTEM TO REMAIN -11. GENERAL CONTRACTOR TO HAVE ARRANGEMENTS MADE FOR TEMPORARY STORAGE OF RADIOLOGY EQUIPMENT. UBC SECTION 904.2.2 ISSUEIREVISION DATE NO. 100% CDS 12/12/0 Q)GODE INFORMATION OSHEETINDEX 3 PARTICIPANTS (D GENERAL NOTES -% Fil NON-RATED PARTFf= 1111► LEAD LNNQ 125 DOOR IDENTIFIER DETAIL IDENTIFIER ADJ. ADJUSTABLE MIN. MINIMUM FULL-HEIGHT JW METAL STUDS 0 16' O.C. `-_ `-:" A7.1 A.F.F. ABOVE FINISH FLOOR MTL. METAL MAX. W/ ONE LAYER 'S TYPE "X" GYPSUM ._ :`•x_:=_`; GYPSUM BOARD HARD WOOD 0mcE NEW ROOM ALUM. ALUMINUM O.C. ON CENTER BOARD EACH SIDE TO 4" ABOVE CEILING W/ :_ _ _ :;; .z VENEER PLYWOOD 125 IDENTIFIER CFT. CERAMIC FLOOR TILE PREY. PREVIOUS LEAD LINING ON INTERIOR SIDE CONC. CONCRETE RE: SHIELDING ANALYSIS (BY OWNER) CONT_ CONTINUOUS P. LAM_ PLASTIC LAMINATE PV. PLANK VINYL a CORR. CORRIDOR RE: A2.0, A3.0 - -: � - _ DETAIL SECTION RB. RUBBER BASE CONCRETE BATT INSULATION STORAGE EXISTING ROOM 1 IDENTIFIER CPT. CARPET RE: REFER 150A IDENTIFIER A1't CWT_ CERAMIC WALL TILE R.O. ROUGH OPENING DBL DOUBLE S.F. SQUARE FEET lfl NON-RATED PAR7fl10N PARTITION DISP. DISPENSER HARD WOOD � EACH S.S. STAINLESS STEEL SCOTT MICHAEL WALL IDENTIFIER BY OWNER ELEC. ELECTRIC STD. STANDARD • NEV1N ' 1J - — — — - ELEV. ELEVATION STOS. STANDARDS FULL-HEIGHT 2 J5w METAL STUDS ® 16" O.C. EQ. EQUAL STRUCT. STRUCTURE �i 202985 V� MAX. W/ ONE LAYER fib" TYPE 'X" GYPSUM "RD ON INTERIOR SIDE. ALIGN FACE W/ OUTSIDE EQUIP. EQUIPMENT (TY P. SUSPENDED FACE OF WALL DUCTS LUMBER INTERIOR EXT. EXTERIOR TYP_) TYPICAL Ail RE: SHIELDING ANALYSIS (BY OWNER) A1.1 1 ELEVATION EXIST_ EXISTING TREAT. TREATMENT R£: A2.0, A3.0 REFERENCE _ GA. GAUGE U.N.O. UNLESS NOTED OTHERWISE 1 GALV. GALVANIZED VCT. VINYL COMPOSITION TILE r GYP. BD. GYPSUM BOARD SV SHEET VINYL I 1• G.C. GENERAL CONTRACTOR �3 EXISTING LEAD LIVED WALLS WOOD BLOCKING I I HPDL HIGH PRESSURE DECORATIVE LAMINATE VVMC VAIL VALLEY MEDICAL CENTER ENLARGED PLAN 1NSUL INSULATION W/ WITH AO WINDOW IDENTIFIER I IDENTIFIER MECH_ MECHANICAL WB. WOOD BASE GENERAL CONTRACTOR TO CONFIRM EXISTING WALLS I I WD. WOOD W COMPLY W/ NEW SHIELDING ANALYSIS PROVIDED BY THE OWNER PLYWOOD D pt coz, z < Lo IMENSION LINE ! W REFER TO 1/A2.0 FOR WALL TAGS 4,- pi .. C)Vb dJ� (,� _.J > r tE CcxjoSE Cr c6k*5--w-_-%ucwtKj J W OC �'Q [/l.[ rfic..L Q ❑ ❑ U p (DWALL fi 47 V�7C �`. ��TYPES MATERIAL SYMBOLS (DSYMBOLS (DABBREVIATIONS • ❑ Ww O APPim01/ED Q Conwmft MW soon OF W= UNE 7i0�JNOF Y�tIL ftf*a� J . ServloM J id1 a x be Cutdb%cd to be •waAe �s w+ISM aIC DOOR AND FRAME SCHEDULE jig - I �a� r�J J ... ........................ :. � a a�+ .IMr.i,.n, ar«tw and �IMIN R�nl�. d J r DOOR — `--- w Prcvm do r. Imrs m said tea.. Q FRAME �—__� � _ _; E a���s b«a= wl4r�dolmas d r ki '144 wpm SIZE ' `---- MATL. MARK WD HGT THK MATL. HARDWARE SET NO.1 NOTES -- 001 4'-0" 7'-0° 1 3/4" WD HM 1 1 LEAD LINED DOOR AND PIVOT FRAME RE: SHIELDING ANALYSIS BY OWNER; COLOR TO MATCH HALLWAY SCHEME _I r GENERAL INFORMATION DOOR HARDWARE SET 1 : i full EXIT 176 1 PIVOT SET RKSON -- -- SWE OF w= vvmc 1 SIDE PIVOT MOON RADIOLOGY ROOM %n 1 PASSAGE SEf LEAD LIB INSIDE ROSE SCHLAGE 1 WALL BUMP IVES I DATE 12/12/2003 I OVERHEAD DOORSTOP GL DRAWN BY BJP 1 SMOKE SEAL PE VIKO RE: HARDWARE CONSULTANT: BOB EURICH, AHC (DENVM CHK'D BY SN SHEET FILE AO-O.dwg COPYRIGHT 2M BY DAVIS PART UMHP PAC.. ARCHITECTS SHEET NUMBER: A0m0 @DOOR AND FRAME SCHEDULE o KEYPLAN ® NOT TO SCALE o VICINITY MAP NOT TO SCALE D.P.A. PROJECT# 03942.00 N N EXISTING PASS THROUGH TO REMAIN REMOVE EXISTING CONSOLE TURN OVER TO OWNER EXISTING CIRCUIT BREAKER BOX TO REMAIN RE ELEC. DEMO CONTROLLER TURN OVER TO OWNER 4� REMOVE EXISTING PHONE MOUNT BOX AND ELEC. SURFACE MOUNTED CONDUIT DEMO WALL AND WINDOWS DEMO EXISTING VCT BOOKING IN ENTIRE ROOM TO CENTERLINE OF DOOR OPENING OONSTRUCTION MANAGER The FKBedc Group RE 7/A3.0 NTROL 1= _ _ _ = RE: ROOM FINISH SCHEDULE FOR NEW FLOORING ON A3.0 PO box am RAD EXAM ROOM 1 Avork Cd mdo81620 002 00 1 REMOVE EXISTING 4'-0" X 6'4' HT. DOOR, FRAME AND HARDWARE 1 ENLARGE OPENING TO ACCEPT A 4'-0" X 7'-0" HT_ DOOR, FRAME AND HARDWARE REMOVE EXISTING X-RAY WALL STAND TURN OVER TO OWNER DAVIS PARTNERSHIP ARCHITECTS 0225 MAIN STREET.UNIT C101 EDWARDS,COLORADO 61632 970.926.8960 F.970.925.8961 II 7'-41�" DEMO EXISTING RUBBER BASE IN ENTIRE ROOM - - - N RE: ROOM FINISH SCHEDULE A3.0 I ISSUE/REVISION DATE NO. i 1 1 REMOVE EXISTING X-RAY TABLE 100% CDS 2/12/03 AND FLOOR MOUNTING BWKET 1 TURN OVER TO OWNER 1 1 CUT AND DEMO EXISTING CONCRETE SLAB FOR NEW TRENCH DUCT RE. 1/A30 AND COORDINATE W/ EQUIPMENT SHOP DRAWINGS BY G. E EXISTING TRANSFORMER TO BE REMOVED RE ELEC. TURN OVER TO OWNER 1 DEMOLITION FLOOR PLAN At0 V4' - T-w COTT, AEk NEViN 202985 �D AR W F- J co Z — u") LU Q co 0 J r J w OC co Q ❑ ❑ o vo ❑ DEMO EXISTING X-RAY SUSPENSION ARM W o ' AND TURN OVER TO OWNER DEMO EXISTING SMOKE DEFECTOR � J O ROL J T REMAIN CONTW b DEMO EXISTING 'N-USE" LIGHT HELD VERIFY YO PRIOR TO W o PREPRING UNISTRUT SHOP DRAWINGS � U � — RAD GAO R00 R EXA ROOM J I oo A I X J rZi OQ 1 r I EXISTING WALL SUPPLY DIFFUSER TO REMAIN — I I I I I I I > co Q _ - 1 ;%ij I DEMO EXISTING EQUIPMENT STATIONARY RAILS I I I I I REUSE EXISTING UNISTRUT IF POSSIBLE — 1 d L J S.D. AND TURN OVER TO OWNER I I I I I I OTHERWISE DEMO T —1 — 1— 1 — 1— T IRE: 3/A3.0 1 _ A — _ — _ _ _ _ _ DEMO EXISTING CABLE DRAPE RAIL r - -I ^ — r - , - — T SAVE FOR POSSIBLE REUSE r -1 I I I I I I I I I I I DEMO EXISTING LIGHTS RE: ELEC. DEMOLITION PLANS r L J DATE 12/12/2003 DRAWN BY BJP CHK'D BY SN SHEET FILE AO-O.dwg 2 DEMOLITION CEILING PLAN 3 DEMOLITION ABOVE CEILING PLAN " " M3 fff MMS PMrP OOP P.C" M01MCM AL V4' - T-w Aw V4' - I-W sl-m MUM: Al ■ D.P.A. PROJECT# 03942.00 LEAD LINED WINDOW RE SHIELDING ANALYSIS (BY OWNER) EXISTING CIRCUIT BREAKER BOX TO REMAIN RE: ELEC_ RETELLS OPERATORS CONSOLE PROVIDE NEW PHONE WALL MOUNTED BY G_E CONCEAL WIRE IN WALL 24 GAUGE BACKING RE: ELEC. BEHIND GYPSUM BOARD RE: INTERIOR ELEVATION 4'-0° x 7'-0' x 1 3/4' LEAD LINED DOOR RE A3.0 NEW FLOOR MOUNTING BRACKETS FOR PROTEUS X-RAY TABLE BY G.E. CONSTRUCTION MANAGER CONTR L The HCBedc Gww 002 � 3 PROTEUS X-RAY TABLE BY G.E. PO BOX 8529 3 15� 007 Avon,Colorado 87620 z FURR OUT WALL FOR FLUSH FIT 3A Eo W/ WALL DUCTS AND MAIN DISCONNECT RE: 4 & 5 A3.0, ELEC. AND G. E. SHOP DRAVANGS 3 RAD EXAM ROOM DAMS PARTNERSHIP ARCHITECTS (STING 001 0225 MAIN STREET.UNIT C101 ao z EDWARDS,COLORADO 81632 i 970.926.8960 F.970.926.8961 m x 2'-9' `a 2 o3 X-RAY WALL STAND BY G.E. 24 GAUGE BACKING BEHIND GYPSUM BOARD EXISTING 4' X 4' WALL DUCT r- W ;., RE: 3/A3.0 ISSUE/REVISION DATE NO. ■ ao ;' 2 i `i 100% CDS 2/12/03 in o n NEW X-RAY GENERATOR FLOOR MOUNTED MOUNTED BY G. E 2'-9' 3 9'-3 " 3' DOSiING NEW CONCRETE FLOOR TRENCH TO ACCEPT 12" X 3" TRENCH DUCT 15'-10" RE 1/A3.0 EXISTING ONE OF THE FOLLOWING MUST BE INSTALLED FOR GE INSITE CONNECTION BASED UPON SYSTEM CONFIGURATION A (1) INTERNET ACCESSIBLE VIRTUAL. PRIVATE NETWORK WITH A STATIC IP ADDRESS AND (1) TELEPHONE LINE - DEDICATED DIRECT-DIALING, VOICE GRADE B_ (2) TELEPHONE LINES - (1) DEDICATED DIRECT-DISTANCE-DIALING, VOICE GRADE AND (1) A DEDICATED DATA LINE RE: ELEC. AND G. E. SHOP DRAWINGS 1 FLOOR PLAN w2.o v4• - 14r p n'9 SCO MICHAEL 7�C NEVIN r� 202985 v� A w F-- —� GO Z — Lo W Q � U J 2 X 4 ARMSTRONG SECOND LOOK CEILING TILE J w co W/ 'We* STANDARD WHITE CEILING GRID aC 0 ❑ o 6' 6' 6' 6' 6' � o ❑ SMOKE DETECTOR 1'-7'L 1'-8' I,Z 2'-6' 4 2'-6' 2'-6' Z 2'-6" 2 RE: ELEC. w w O NEW XT RADIOGRAPHIC SUSPENSION WITH INBOARD MOUNTING. w ❑ o INSTALLED 8Y G. E COORDINATE W/ GENERAL CONTRACTOR � J o C TRO EXISTING CONCRETE Jasr_ TO REMAIN � � W o NEW IN-USE' LIGHT ABOVE 02 RA EXAM 'ROOM FIELD VERIFY LAYOUT PRIOR TO CON R0 I_ _XAM ROOhV O S.D RE: ELEC_ AND G_ E_ SHOP DRAWINGS PREPARING UNISTRUT SHOP DRAWINGS 001 o DO1 LIGHTS TYP. RE: ELEC. J ^ J O IXISTING WALL SUPPLY DIFFUSER TO REMAIN GENERAL CONTRACTOR TO CLEAN ' co J M_ > DIMENSIONS PROVIDED TO SHOW _- - - -. - DIFFERENCE BETWEEN EXISTING STRUCTURE AND NEW UNISTRUT LAYOUT LONGITUDINAL NEW STATIONARY RAIL FOR XT SUSPENSION REQUIRED BY G. E. NEW UNISTRUT OR REUSE EXISTING UNISTRUT. Fl INSTALLED BY G. E COORDINATE: W/ GENERAL CONTRACTOR UNISTRUT SUPPORT CAPACITY INCLUDING ANCHORAGE ' IS TO BE COORDINATED W/ G. E. AND A LETTER IS O TO BE PROVIDED NOTING EXISTING STRUCTURE CAN V SUPPORT NEW EOUIPMENT'S STATIC AND DYNAMIC LOADS 0 0 ----- - PLANS 94E CF r_­&lw(XlAJ6 #t7 rwEin N w 2'-2' 2'-2" 1 2'-2' 1 2'-2' 1 2'-2" SPcrtr R SUPPORT REQUIREMENT PROVIDED BY 2' DATE 12/12/2003 DRAWN BY BJP REUSE EXISTING CABLE DRAPE RAIL IF POSSIBLE EQUIPMENT SUPPLIER (G. E.) RAIL PROVIDED BY GENERAL CONTRACTOR CHK'D BY SN SHEET FILE AO-O.dwg 2 CEILING PLAN 3 ABOVE CEILING PLAN ooPYRIG14 2M BY DAVIS PARTNERSHIP Q.C.' ARCHftECTS A2.0 v4' - 1'-0' A2A V4' - T-0' SHEET NUMBER: ■ D.P.A. PROJECT# 03942.00 ROOM FINISH SCHEDULE EXISTING SLAB tNOSE WALLS CEILING NEW SLAB TO MATCH ROOM NO ROOM NAME FLOOR a4SE MAT. COLOR N S E I IN I MAIL HEIGHT EXISTING W/ 001 RAD E MM ROOM VCT 1 Na I Pr 1 PF t PT 2 Pr t CLM 1 8'-7' FI B ERM ES H TO 002 CONTROL_ VCT t RB I PT 1 � t PT 21K t CLN6 t s'-7' MATCH EXISTING � 12 x 3' TRENCH DUCT BY G. E RUBBER BASE: ROPPE: COLOR 1= P172 CHAMPAGNE � VCT 1 = MANNINGTON #407 2'-g. PT 1 = SHERMAN WILLIAMS PAINT SW 1116 VELLUM PT 2 = SHERMAN WILLIAMS PAINT WS 1188 BURMESE JADITE CLNG 1 = ARMSTRONG SECOND LOOK W/ 2 X 2 LOOK, l%s" 1'-1' GENERAL NOTE: ALL NEW AND EXISTING WALL DUCT TO BE PAINTED TO MATCH ADJACENT WALL it �4 -4 • _ 4 e q ' " - CONSTRUCTION MIANAGER a The HCBe&Group PO BOX 8529 Avon,Colorado 81620 0 1/2"Ox1'-0" FLOOR DUCT TO BE FLUSH DOWELS AT 12" W/ FINISHED FLOOR, DAVIS PARTNERSHIP ARCHITECTS O.C.. DRILL AND GROUT AS REQUIRED 0225 MAIN STREET.UNIT C101 EPDXY 5" MIN. INTO EDWARDS,COLORADO 81632 6 EXISTING SLAB 970.926.8960 F.970.926-8961 3 AlD 5 DO NOT UNDERMINE EDGE OF EXISTING SLAB 4 ISSUE/REVISTON DATE NO. ❑ 1 DETAIL A8A 1 v2• - r-O' 100% CDS 2/12/03 0 0 2 KEY PLAN AND FINISH SCHEDULE A8A v4• - r-0• NEW 10' X 3 1/2' SURFACE WALL DUCT QQ EXISTING 4' X 4' SURFACE WALL DUCT 21� 0 o _r r p MICHAEL EXISTING aRcur BREAKER NEVC EN PROTEUS GENERATOR BOX TO REMAIN BY G. E. I RE: ELEC. NEW PHONE `/ 202985 NEW PROTEUS GENERATOR w EXISTING PASS THROUGH RE: ELEC. BY G. E EXISTING 4 X 4 10 / 24 GAUGE STEEL SHEET KING TO REMAIN �1) AR I SURFACE DUCT / ATTACH TO STEEL STUDS UNDER GYPSUM BOARD NEW 10' X 3 1/2" SURFACE WALL DUCT PID NEW PROS WALL STAIN BY G. E �— NEW 1 1/2' DIA CHASE PILE 4 \ COVERPLATE " 1 6' X 4' W 1 T-Ti' o ` _ • NEW PHONE AND NETWORK CONNECTION w/ Z NEW 12' X 3' TRENCH DUCT CONDUIT TO VERY. TO ABOVE FINISHED CEILING PROVIDE {2) 16 GAUGE STEEL STUDS co EACH SIDE OF DOOR JAMB TO STRUCTURE co UJ � � J w co < 0 00 V0 3 INTERIOR ELEVATION 4 INTERIOR ELEVATION 5 INTERIOR ELEVATION 6 INTERIOR ELEVATION 0 2 A8:0 v4• - r-w AS.O v4• -'r-0 AS.O v4• - r-w ASA v4• - T-0• w w 0 00 }. < J w0 w � V w --� X J NEW EMERGENCY OFF SWITCH vw " > co Q 3'--O' J �-- 4'-a' 2'-6' Q 11 \ \ LEAD LINED FRAME N m RE: SHIELDING ANALYSIS TTY OWNER z VERITY DIM. W/ CD LI: T7OOR PLAN, TYP. vERl�r DIM. w/ INTERIOR ELEVATIONS �- FLOOR PLAN. TYP. )5.,� ,.� & DETAILS 16 GAUGE STL FLANGE NEW 2 1/2' DML CWSE NIPPLE STAINLESS STEEL, TYPE 430, 16 GAUGE a ANCHORAGE, AND COVERPLATE KICKPLATE W/ L-BEND AT DOOR EDGES LENT SHIELDING ANCHORAGE, N RE: SHIELDING ANALYSIS LEADED GLASS LEAD LINED DATE 12/12/2003 6 X 6 X 4 BOX BY OWNER RE SHIELDING ANALYSIS RE: SHIELDING ANALYSIS BY OWNER BY OWNER BY BJP NEW PROTEl15 OPERATOR'S CONSOLE CHK'D BY SN 1tg"1YP CONTROL SIDE RADIOLOGY ROOM SIDE 24 GAUGE SHEET BACKING IN WALL SHEET FILE AO--O.dwg COPYRIGHT 2003 a1' DAMS PARTNERSFIP P.G.. ARCIIIEECTS 7 INTERIOR ELEVATION 8 DOOR ELEVATION - 001 S WINDOW ELEVATION 10 DOOR JAMB DETAIL 11 WINDOW JAMB DETAIL SHEET NUMBER- A8A v4• - r-w A3A v4• - T-fl AS.O v49 - r-W A8 O i vL" - r-0' A8 O i V2• - Tom' ■ D.P.A. PROJECT# 03942.00 NOTE: ALL SYMBOLS SHOWN ON LEGEND ® ® GENERAL NOTES (FOR ALL ELECTRICAL ME12 EII EGTRI -AL LEGEND ARE NOT NECESSARILY USED. 1. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS, LIGHTING SCHEMATIC WIRINQ GRAPHICS 2. ALL 120V BRANCH CIRCUITS SHALL BE 3—WIRE (PHASE,NEUTRAL.GROUND). PHASE, MKK C ENGINEERS INC . NEUTRAL, AND GROUND CONDUCTORS SHALL BE SIZE 12 AWG UNLESS OTHERWISE O DOWNUGHT METER NOTED. OH WALL MOUNTED FLUORESCENT OR INCANDESCENT GROUND CONNECTION AS NOTED Mechanical, Electrical & Energy❑ Consultants 3. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AND DIAGRAMS FOR LOCATIONS OF LUMINAIRE, AS NOTED --� DISCONNECT SWITCH FLOOR AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/ OR FUSES HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE POWER 7350 East Progress Place, Suite 100 MOUNTED LONG AXIS HORIZONTAL AT +18" AFF TO CENTER. � STRAIGHT BLADE DUPLEX RECEPTACLE — MAGNETIC MOTOR STARTER Englewood, Colorado 80111 CONSTRUCTION MANAGER g 4. PROVIDE TYPED UPDATED PANEL DIRECTORIES FOR ALL EXISTING PANELS AFFECTED The HCBeok Ga4 JUNCTION BOX, AS NOTED CIRCUIT BREAKER. MOLDED—CASE, (303) 721--6600 BY REMODEL WORK. PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS PO BOX 8529 �J OUTLET BOX THERMAL—MAGNETIC www.mkkeng.com REQUIRED. Awx%Colo aft 81620 Qj WALL MOUNTED OUTLET BOX ENCLOSED CIRCUIT BREAKER, MOLDED—CASE, 5. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS ENCLOSED CIRCUIT BREAKER, MOLDED—CASE, THERMAL--MAGNETIC 500 West 18th Street, Suite 200 7535 Hilltop Circle AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS 0 Cheyenne, Wyoming 82001 Denver, Colorado 80221 WOULD ALLOW, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE. THERMAL—MAGNETIC ENCLOSED FUSED DISCONNECT SWITCH (307) }634-7647 (303 428-8808 PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF REMODEL WORK ,--9 CONNECTION TO PRE—WIRED EQUIPMENT REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE DAMS PARTNERSHIP ARCHITECTS 0225 MAIN STREET. UNIT C101 MIS BREAKER PANEL POWER TRANSFORMER NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT EDWARDS.COLORADO 81632 827 Rood Avenue 10$15 David Taylor Drive, Suite 170 DOCUMENTS. 970.926.8960 F.970.925.8981 SS TRANSIENT VOLTAGE SURGE SUPPRESSOR CURRENT TRANSFORMER Grand Junction, Colorado 81501 Charlotte, North Carolina 28262 TRANSFORMER AMMETER (970) 245-3177 (704) 717-9950 6. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER PRIOR TO ROUGH—INS. Q VOLT METER COORDINATE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL ELEVATIONS, 175 N. 27th St., Suite 902 CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS. COORDINATE CIRCUITING TRANSFER SWITCH Billings, Montana 59101 LOCATION OF LUMINAIRES WITH ARCHITECTURAL REFLECTED CEILING PLANS. CONDUIT RUN (406) 256-1141 ® 7. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE ISSUFJRfVISION DATE NO. CIRCUIT HOMERUN TO PANEL OR CABINET, CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. NO. OF ARROWS INDICATE NO. OF CIRCUITS FOR PERMfr 2/12/03 Ci GENERATOR 8. PROVIDE (1) 3/4"C WITH BUSHING AND PULL WIRE FROM EACH TELEPHONE, DATA COMMUNICATION SYSTEM OR COMMUNICATION OUTLET SHOWN, TO ABOVE ACCESSIBLE CEILING. V WALL MOUNTED TELEPHONE OUTLET 3 MOTOR. NUMBER INDICATES HORSEPOWER 9. ALL ITEMS SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. ALL ITEMS SHOWN HEAVY LINE WEIGHT ARE NEW, OR RELOCATED AS WALL MOUNTED DATA OUTLET NOTED. 0 WALL MOUNTED COMBINATION TELEPHONE/DATA SWITCHING ABBREVIATIONS 10. ON DEMOLITION PLANS, ALL ITEMS SHOWN HEAVY LINE WEIGHT SHALL BE REMOVED, OUTLET BOX S WALL MOUNTED SWITCH UNLESS OTHERWISE NOTED, ALL ITEMS SHOWN LIGHT UNE WEIGHT ARE EXISTING TO CEILING OR WALL MOUNTED SPEAKER SUBSCRIPTS: NOTE: ALL ABBREVIATIONS SHOWN REMAIN, UNLESS OTHERWISE NOTED. FIRE ALARM MTEM D = DIMMER ARE NOT NECESSARILY USED. 11. MAINTAIN CIRCUIT CONTINUITY FOR ALL EXISTING ITEMS THAT ARE REMAINING OR ® �}I CEILING OR WALL MOUNTED DETECTOR BEING RELOCATED. AC — ABOVE COUNTER AFC — ABOVE FINISHED CEILING 12, ALL NEW WIRING REQUIRED IN REMODELED AREAS SHALL BE FISHED THROUGH AFF — ABOVE FINISHED FLOOR EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS, SURFACE AFG — ABOVE FINISHED GRADE MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS. CONTRACTOR AIC — AMPS INTERRUPTING CURRENT SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS NOTED TO DO SO. AL — ALUMINUM CO — CIRCUIT BREAKER 13. ALL ITEMS SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY CU — COPPER INCLUDING ALL ASSOCIATED CONDUIT AND WIRE BACK TO POINT OF ORIGIN OR DF — DEMAND FACTOR NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS OTHERWISE NOTED. WHERE EST — ESTIMATED EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM FLA — FULL LOAD AMPS WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK COVE RPLATES OVER GFI — GROUND FAULT INTERRUPTER EXISTING BOXES ARE NOT ACCEPTABLE. IF EXISTING CONDUITS ARE ROUTED IN MCA — MINIMUM CIRCUIT AMPS CONCRETE FLOOR SLABS. WALLS OR CEILINGS, THEY SHALL BE CUT BACK TO WITHIN MCB — MAIN CIRCUIT BREAKER CONCRETE AND FILLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH MLO — MAIN LUGS ONLY WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. NC — NORMALLY CLOSED NIC — NOT IN CONTRACT 14. PROVIDE 1/4" TAPE LABELS ON ALL RECEPTACLES AND SWITCHES THAT INDICATES PANELBOARD AND CIRCUIT NUMBER. LABELS SHALL BE BLACK NO — NORMALLY OPEN LETTERS ON WHITE OR CLEAR BACKGROUND. NTS — NOT TO SCALE OC — OVER CURRENT 15. COORDINATE INSTALLATION OF COMMUNICATION CABLING, TERMINATIONS, AND OL — OVERLOAD DEVICES WITH HOSPITAL. PF — POWER FACTOR 16. WORK UNDER THIS CONTRACT IS IN OCCUPIED SPACES AND EQUIPMENT ROOMS. W SC — SHORT CIRCUIT CONTRACTOR SHALL SCHEDULE AND COORDINATE WORK AND ANY EXISTING V NC — VAIL VALLEY MEDICAL CENTER EQUIPMENT DOWNTIME WITH THE OWNER. ALL WORK OUTSIDE CONSTRUCTION J XFMR — TRANSFORMER BARRIERS SHALL BE DONE DURING OFF OR WEEKEND HOURS. Z —�- E 17. ALL RECEPTACLES IN PATIENT CARE AREAS AS DEFINED IN NEC 517.2 SHALL U BE HOSPITAL GRADE. Cn I& THE ELECTRICAL CONTRACTOR SHALL MAINTAIN FIRE RATINGS FOR ALL CONDUIT o E PENETRATIONS THROUGH FIRE RATED CONSTRUCTION. CL d ❑ ❑ N 19. ALL CONDUIT AND WIRE SHALL BE CONCEALED EXCEPT IN ELECTRICAL ROOMS. U ❑ LO N 20. ALL NEW AND RELOCATED LUMINAIRES SHALL BE SUPPORTED INDEPENDENTLY ❑ OF CEILING SUPPORT HANGERS, IN COMPLIANCE WITH UBC REQUIREMENTS W W o (U 21. ALL ABANDONED WIRING SHALL BE REMOVED FROM DUCTS OR CONDUIT. ❑ p 22. ALL FLOOR PENETRATIONS SHALL BE X—RAYED AND THE X—RAYS INSPECTED AND '-' W o L APPROVED BY THE OWNER PRIOR TO DRILLING OR CORING. ALL PENETRATIONS W 4 SHALL BE FIRE—PROOFED. ANY PENETRATION LARGER THAN 1/2" SHALL BE CORE—DRILLED. o, ..j X J > 00 Q J � � S H a 0 CD ELECTRICAL W COVER SHEET A a, CD DATE 12/12/2003 U DRAWN BY CMP d CHK'D BY CMP L SHEET FLE E1.O.DWG C5 L COPYRIGHT 2003 By DAVIS PARTNERSHIP P.C., ARCHITECTS I X El mO f ('7 %D / D.P.A. PROJECT# 03942.00 E GENERAL NOTES: 2 1. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER AND WITH GE 1 MEDICAL SYSTEMS INSTALLATION DRAWINGS PRIOR TO ROUGH-INS. 2 2. ALL CONDUIT AND DUCT RUNS SHALL HAVE LONG SWEEP BENDS. 3. CONDUITS AND DUCT INSTALLED ABOVE CEILING OR BELOW FLOOR MUST BE INSTALLED AS NEAR TO CEILING OR FLOOR AS POSSIBLE I o I I 0 TO REDUCE RUN LENGTH. I 1 I I i CONSTRUCTION MANAGER I i I I I I I I 4. ALL DUCTWORK SHALL BE CERTIFIED/RATED FOR ELECTRICAL POWER The O BOX eck G� PURPOSES AND SHALL BE ELECTRICALLY AND MECHANICALLY ia c BONDED TOGETHER IN AN APPROVED MANNER. Avon, Cdarado 81620 6. ALL WIRES SPECIFIED SHALL BE STRANDED, FLEXIBLE, THHN/THWN, (TYP. " ° I I I I " I' COLOR-CODED, COPPER ONLY, CUT 10'-0" LONG AT OUTLET BOXES. DUCT TERMINATION POINTS OR STUBBED CONDUIT ENDS, UNLESS SIGNAL AND GROUND, I � I ,� I OTHERWISE NOTED. ALL CONDUCTORS. POWER, DAMS PARTNERSHIP ARCHITECTS MUST BE RUN IN CONDUIT OR DUCT SYSTEM. RING OUT AND TAG 0225 MAIN STREET.UNIT C101 I r -- -- -- - I ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BE CONTINUOUS AND EDWARDS.COLORADO 81632 ' I FREE FROM SPLICES. I I I T I I I ' I I I 970.926.8960 F.970.926.8961 z I I_ _, I I _ m 7. ROUTING OF CABLE DUCTWORK, CONDUITS, ETC., OTHER THAN s I o Q SHOWN ON THIS DRAWING MAY RESULT IN THE NEED FOR GREATER THAN STANDARD CABLE LENGTHS (REFER TO GE MEDICAL SYSTEMS J_- - - - -- - DRAWINGS FOR MAXIMUM USABLE LENGTHS POINT TO POINT. ISSUE/REVISION DATE NO. 1 I I l i 1 I 3 I " FOR PERMIT 2/12/03 FLAG NOTES THIS SHEET: O J ' 1 1. EXISTING DISTRIBUTION PANEL "DHA" IS LOCATED IN THE EAST MAIN I I \ 3 ELECTRICAL ROOM. REFER TO "SECOND FLOOR KEY PLAN", THIS Q1 TO "DHA" SHEET FOR ROOM LOCATION. 2. REMOVE EXISTING WARNING LIGHT. PROTECT EXISTING 120V BRANCH CIRCUIT FOR REUSE UNDER NEW WORK. REFER TO "X-RAY ROOM r� POWER AND SYSTEMS PLAN". THIS SHEET. FOR MORE INFORMATION. F-f NORTH _ V I E W G D ARK R M 3. NEW WARNING LIGHT. CONNECT TO EXISTING 120V BRANCH CIRCUIT, X-RAY ROOM LIGHTING ELAN w SCALE: 1/8" = V-0" 4. PROVIDE 11 SQUARE, RECESSED INCANDESCENT DOWNLIGHTS WITH 8' 0 8' 16' NORTH TEMPERED PRISMATIC LENS AND REGRESSED WHITE DOOR, LITHONIA � X—RAY R00� POWER AND MTEMS PL N �►-11RW-T73, OR ENgNEER-APPROVED EIX1AL. PROVIDE (1) 100W .... A-19 LAMP FOR EACH LUMINAIRE. SCALE: 1/4' a 1'-0" 5. REMOVE EXISTING CIRCUIT BREAKER. PROTECT EXISTING ENCLOSURE 4' 0 4' 8' FOR REUSE UNDER NEW WORK. REFER TO "X-RAY ROOM POWER AND SYSTEMS PLAN% THIS SHEET, FOR MORE INFORMATION, 6. PROVIDE 150OW, WHITE, SLIDE-TO-OFF DIMMER SWITCH, LUTRON #NT-1500--W-I. OR ENGINEER-APPROVED EQUAL. 7. REMOVE EXISTING SMOKE DETECTOR AND REINSTALL ON NEW CEILING. EXTEND EXISTING FIRE ALARM CIRCUITRY AS NECESSARY. 8. REMOVE EXISTING LUMINAIRE. PROTECT EXISTING 120V NORMAL LIGHTING BRANCH CIRCUIT ORIGINATING FROM PANEL "L1 A" LOCATED . ELECTRICAL LEGEND IN CORRIDOR APPROXIMATELY 75' WEST of THE X-RAY ROOM. 9. CONNECT TO EXISTING LOCAL 120V NORMAL LIGHTING BRANCH WIREWAY CIRCUIT ORIGINATING FROM PANEL "L1A". PRIOR TO NEW WORK. 0 DESCRIPTION ELECTRICAL HARDWARE VERIFY WITH AMMETER THAT THE BRANCH CIRCUIT DOES NOT EXCEED 6.0 AMPERES WITH ALL LOADS SWITCHED ON. A MAIN DISCONNECT PROVIDE NEW 7OA3P, 48OV, 30, 14,000AIC, RECESSED, ENCLOSED MOLDED-CASE CIRCUIT BREAKER. ----- MOUNT IN EXISTING CIRCUIT BREAKER ENCLOSURE, w DLK1 DOOR SWITCH PROVIDE NORMALLY OPEN 24V DC SAFETY DOOR INTERLOCK LIMIT SWITCH. THE ROOM DOOR SHALL BE CLOSED TO ALLOW X-RAY OPERATION. . MOUNT +6'-6" AFF TO CENTER. J to C I 0 K CASSETTE HOLDER PROVIDE 6"X6"X4" DEEP PULLBOX WITH 1-1/2" DIAMETER CHASE NIPPLE AND COVERPLATE. MOUNT W Q u I FLUSH IN WALL +2'-3" AFF TO CENTER. U J ' r OC CONTROL. CONSOLE PROVIDE 6"X6 X4 DEEP PULLBOX WITH 2-1/2" DIAMETER CHASE NIPPLE AND COVERPLATE. MOUNT +� ------ 1+ FLUSH IN WALL +1'-6" AFF TO CENTER. LL � I ;� It PT TABLE PROVIDE (2) 1-1/4" DIAMETER SHORT NIPPLES WITH BUSHINGS AND LOCKNUTS. ♦ , 0 ❑ (u I -------31 V Tr) - ct� I Q XG GENERATOR PROVIDE 32" OF GROMMET MATERIAL FOR AN 8"X8" OPENING IN DUCT COVER. PROVIDE 6'-0" OF ❑ CD I n 1-1/2" FLEXIBLE METAL CONDUIT, AND (2) 1-1/2" 90 DEGREE CONNECTORS. IX-RAY w I.LI 0 C) XRLI WARNING LIGHT PROVIDE PRESCOLITE JEX1R X-RAY ON INCANDESCENT LUMINAIRE, OR ENGINEER-APPROVED EQUAL. ❑ Q N 24V, BA OR LESS LOW VOLTAGE SOURCE. MOUNT 6" ABOVE DOOR. J XTS1 X-RAY TUBE HANGER PROVIDE 32" OF GROMMET MATERIAL FOR AN 8"X8" OPENING IN DUCT COVER. W 0 a £ 2 � SWD-1 SURFACE WALL DUCT PROVIDE 10"X3-1/2" SURFACE WALL DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS. J i�Ell u 0 SURFACE MOUNT +0'-9" AFF TO CENTER. - J a x J A SWD-2 SURFACE WALL DUCT PROVIDE 10"X3-1/2" SURFACE WALL DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS. • . Q -� SURFACE MOUNT FROM FINISHED FLOOR TO +1'-0" ABOVE FINISHED CEILING • - - . 00 a 0 SWD-3 SURFACE WALL DUCT EXISTING 4"X4" SURFACE WALL DUCT. - - J t N 5 3 TD TRENCH DUCT PROVIDE 12"X3" TRENCH DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS. ��- a MOUNT FLUSH IN FLOOR. FIRST FLOOR KEY PLAN > a NO SCALE o EL NORTH X-RAY ROOM ELECTRICAL DEMOLITION PLAN FEEDER SCHEDULE ELECTRICAL SCALE: 1/8" V-0" EAST MAIN t p C5 8' 0 8' 16' WIRE AND CONDUIT SIZE PLANS i ELECTRICAL 1) Q, 1 2-1/2"C WITH PULLWIRE ROOM 3c a 2 (2#112+#12G)1/2"C i DATE 12/12/2003 3 (4#4+#1/OG)1-1/4"C ` - DRAWN BY CMP 6 - 4 (3#t4+#I/OG)1-1/4"C CHK D BY CMP SHEET FILE I E2.O.DWiG 6 COPYRIGHT 2003 BY OMVIS PARTNERSHIP P.C., ARCHffECTS I - X OHM MAIM V f > NORTH_ SECOND FLOOR KEY PLAN • NO SCALE D.P.A. PROJECT# 03942.00 z a i i i LOAD JUSTIFICATION FOR MAIN OIST, PANEL "DHA" PEAK LOAD REPORTED OVER LAST 12 MONTHS AS REPORTED BY HOLY CROSS ENERGY: 260.0 KW (AUGUST 2003) = 305.9 KVA (0 85% PF) X 125% = 382.3 KVA CONSTRUCTION MANAGER The HCBeck Group DEMAND LOAD REMOVED: PO BOX 85n OLD X-RAY UNIT EST,) = 18.0 KVA X 100X 18.0 KVA Avon,Colorado 81620 " " FROM PANEL "LIA (LIGHTING) = 0.8 KVA X 125X _ 1.0 KVA LOAD JUSTIFICATION FOR PANEL L1 A TOTAL DEMAND LOAD REMOVED: 19.0- 100A. 120/206V, 30. 4W DEMAND LOAD ADDED: NEW X-RAY UNIT = 48.5 KVA X 100X - 48.5 KVA DAVIS PARTNERSHIP ARCHITECTS DEMAND LOAD REMOVED: TO PANEL "Lt A" (LIGHTING) = 1.1 KVA X 125X - 1.4 KVA 0225 MAIN STREET.UNIT C101 E.D. RENOVATION PROJECT, TOTAL DEMAND LOAD ADDED: _ 49.9 KVA EDWARDS,COLORADO 81832 ISSUED 10-3-03. REVISED 11-7-03 = 2156 VA X 100X - 2156 VA 970.928.8960 F.970.926.8961 LIGHTING - 800 VA X 125X - 1000 VA NET DEMAND LOAD ADDED; 30.9 KVA TOTAL DEMAND LOAD REMOVED; - 3156 VA TOTAL DEMAND LOAD: = 413.2 KVA DEMAND LOAD ADDED: LIGHTING = 1100 VA X 125X = 1375 VA MAIN DISTRIBUTION PANEL CAPACITY: NET DEMAND LOAD REMOVED: = 1781 VA 2000A FUSES IN MAIN DISCONNECT SWITCH = 1662.8 KVA ISSUEIREVISION DATE NO. FOR PERMIT 2/12/03 FLAG NOTE ,; O 1. REUSE EXISTING SPARE FUSED SWITCH. PROVIDE NEW FUSES AS INDICATED. O "L1 A" "L1A1" 2. REMOVE EXISTING CIRCUIT BREAKER AND FEEDER BACK TO SOURCE. X-RAY 3. SHORT CIRCUIT VALUES BASED ON 500KVA UTILITY TRANSFORMER WITH RM B IMPEDANCE Z=1.5X 100A 3P 60A3P TO TO TO "LPC"/ TO FLASH TO TO TO TO "P1" 4 "PP1" "LPD" ATS-2 STERILIZER 7 "MCC" ATS-3 "LPL" ATS-1 400A 1000A 600A 200A 600AA 40A OOA - 100A IO A 150A 175A 175A 300A ' I JJN JJN JJN JiN JJN i I I FRN FRN FRN FRN FRN FRN FRN FRN 400A 1200A 600A 400A 600A 60A 100A 100A 100A 100A 100A 200A 200A 200A 400A I 3P 3P 3P 3P 3P I SPACE I I 3P 3P SPARE 3P SPARE 3P 3I? 3P 3P w CL DISTRIBUTION PANEL "DLA" DISTRIBUTION PANEL "MDP" 1 Lo / 3000A 120/208V. 30. 4W, 1000A L.1.1 � f 20 208V, 3�. 4W, rr �� ` 100,000 AIC V J / r W ❑C c o C Q ❑ ❑ 0 00 L Lb 3: ❑ Lo AHU COND. "PG- UNIT (ROOF) "PG- "PG- ❑ c BL1 Al" NEW BH1 A" CT DHM" W w 0 N RF M X-RAY SCAN ❑ 0 ROOM 125A RM B TO 125A3P Q J FRS-R 70A "PG-AMBULANCE BL1 A" L BUILDING 200A 3P KI FEEDERS 10OA3P 3 225A3P 1200A W °i 200A LIEBERT MOB MCB 3P GFI 1 u INTERCEPTOR MCB J ^ J FUSES SHORT CIRCUIT SCHEDULE A 200A TVSS LIDS 3 < r 00 Q SS #BG 400A3P X SHORT CIRCUIT CURRENT ® �, i 3OKVA, 45KVA, 75KVA, #2G J 480- 480- - 1 40,094A - 208V. - 20�8V. - 208V. - � _ 30,4W 30,4W 30,4W 500KVA. 2 36,487A °i 480-120/ 3 11,073A 0 500 KVA FUSES HOLY CROSS 6 2 20OV.30.4W a HOLY CROSS SECONDARY 100A - - - - - - # PAD-MOUNTED R 3P I I ONE-LINE DIAGRAM � 15oA 60A 45A 70A 70A 200A 110A 125A 1200A 750A FEEDER SCHEDULE Q (SERVICE 2R) f f GF I LPS FUSES FUSES FUSES FRS--R FUSES LPS LIDS LIDS FUSES I M AND LOAD w 3000A 2000A 200A 200A 60A 100A 100A 1 OOA 200A 100A 200A 200A 1200A 1200A JUSTIFICATIONS Q T 3P FUSES 3P 3P 3P 3P 3P 3P 0 3P 3P 3P 3P 3P 3P MARE AND CONDUIT SIZE 3 I p I I I SPACE SPACE I 1 6[(4-500KCMIL+#1/OG)4"C]+2(4"C) 2 2[(3-500KCMIL+#1/OG)3"C]+4(3"C) DATE 12/12/2003 m _ _ DID UTION PANEL UHA 4(3-1/2-C) CllrlP 1 2 - #4/OG TO BUILDING 3 4[(4-250KMIL+2#2G)3-1/2"C]+ DRWN BY C5 STEEL AND COLD 480V. 30, 4W, 3000A 'D a WATER PIPES 100,000 AIC 4 3[(4-500KCMIL+#2/OG)3-1/2"C] CHK BY CMP L = = Z 500KCMIL,G TO "MDC" >, 1 PART4L EAST NORMAL 5 (2�n/o+ 3G)1-1/z"c SHEET E3.o.ITWG L COPYRIGHT 2003 B'Y DAMS PMUW-RSHIP P.C., ARCHfI M X POWER- ONE-LINE DIAGRAM , ( +�1/OG)1.-1/4"C (4#2+�8G)1-1/2 C slur N v NO SCALE > -4 E3mO %0 D.P.A. PROJECT# 03942.00 o, ELECTRICAL SPECIFICATIONS— DIVISION ,, PART 1 GENERAL 2.05 OWNERSHIP 3.06 DEVICES 1.01 CODES AND REQUIREMENTS A. All equipment, fixtures, devices, etc. which are removed shall be A. Receptacles and switches: configuration shall conform to NEMA presented to the Owner for disposition. All items which are WD-1. Device body shall be ivory plastic unless otherwise noted. A. All electrical work shall comply with the requirements of the removed but not wanted by the Owner and which are not reused latest edition of the National Electrical Code, Local Building become the property of the Contractor and shall be removed B. Mount devices in accordance with the following schedule Code, and as specified herein, whichever Is more strict. from the site. except where otherwise noted on the drawings: CONSTRUCTION MANAGER B. The Contractor shall comply with the requirements of the PART 3 PRODUCTS 1.) Convenience receptacles— long axis horizontal 1'-6"AFF The HCBedcGmup General Conditions, Supplemental General Conditions, of the 2.) Light switches— latch side of door 4'-0"AFF PO BOX 8529 project specifications, ail Contract Documents, and any base 3.01 EQUIPMENT Avon,Colorado 81820 building specifications and building criteria Included in this 3.07 ENCLOSED CIRCUIT BREAKERS project. A. The Contractor shall provide all equipment and accessories necessary, whether specifically stated or not, to make the A. Enclosed molded—case circuit breaker: NEMA AB 1. Circuit C. Visit the premises before submitting bid as no extras will be required electrical systems complete and operational. breakers shall shall bear the UL label and each enclosure shall allowed for lack of knowledge of existing conditions. be the NEMA type suitable for the surrounding area and DAVIS PARTNERSHIP ARCHITECTS B. All equipment provided shall be new except as otherwise stated conditions. Circuit breakers shall be thermal—magnetic with 0225 MAIN STREET. UNIT C101 D. Drawings are diagrammatic In nature. Take all dimensions from on the drawings. All equipment provided shall be U.L. listed inverse time—current element for low—level overloads and EDWARDS.COLORADO 81632 Architectural drawings, certified equipment drawings, and from when such standards exist for the type of equipment furnished. instantaneous trl ished, p element for short circuits. Circuit breakers 870.928.8980 F.970.926.8861 the structure itself before fabricating any work. and acceptable for installation by the Local Building Authority. shall have interrupting capacity to meet available fault currents. F. Good workmanship and appearance are considered equal to 3.02 ELECTRICAL IDENTIFICATION B. Switches and circuit breakers shall be as manufactured by Cutler— proper operation. Hammer, General Electric, Siemens, Square D, or as accepted, and A. Provide labeling for receptacle and wall switch coverplates as all switches and circuit breakers provided shall be by the some G. Provide all core drilling. channeling, cutting, patching, as specified on the Drawings. manufacturer. ISSUE/REVISION DATE NO. required for Installation of electrical equipment. Seal holes, fireproofing where necessary, and refinish all repair work to B. All junction boxes shall be Identified as to circuits contained 3.08 LIGHTING FIXTURES FOR PERMIT 2/12/03 original condition where damaged by electrical work. within. A. Provide all new lighting fixtures complete with lamps, ballasts, H. Make provisions for safe delivery and secure storage of all C. Provide engraved nameplates for all electrical cabinets, enclosures, reflectors, plaster frames, louvers, stem hangars, etc., and as materials. ponelboords, distribution equipment, electrical equipment, boxes, etc. described on the drawings. I. Provide the Architect with a complete set of plans and 3.03 CONDUCTORS 3.09 FUSES specifications corrected to as—built conditions at the completion of the job. A. Minimum size #12 AWG except for control circuits which may A. Fuses shall be as manufactured by Bussmann unless noted be #14 or signal circuits which shall be as Indicated. All otherwise on the drawings. 1.02 WARRANTY conductors shall be copper. PART 4 EXECUTION The Contractor shall provide for the Owner a one—year (from the B, Splices for #6 and smaller conductors — Twist—on wire connectors. date of final acceptance) warranty of all electrical equipment and 4.01 CONDUITS/RACEWAYS systems provided under this contract except for incandescent or C. Splices for — and larger conductors — Solderless or fluorescent lamps. All defective equipment or materials which compression—type CU/ALR lugs. A. All conductors shall be enclosed by conduit sized In accordance appear during the warranty period shall be replaced or repaired by with Annex C of the National Electrical Code. Minimum 1/2" the Electrical Contractor in a timely fashion. D. Wiring, type THHN/THWN, unless otherwise noted. except for factory furnished lighting fixture flexible conduit may be 3/8". PART 2 ELECTRICAL DEMOLITION E. Color Coding: Wiring for control systems to be Installed in conjunction with mechanical and miscellaneous equipment shall 1.) Electrical metallic tubing (EMT) shall be utilized for all 2.01 MATERIALS AND EQUIPMENT be color coded In accordance with the wiring diagrams dry, above grade or above floor applications In accordance furnished with the equipment. Branch circuit wiring, Including with Article 358 of the National Electrical Code. Couplings A. Materials and Equipment for patching and extending work as circuits to motors, and all feeders shall be coded by line or shall be steel compression type, made up wrench—tight. specified in individual sections. phase as follows: 2.02 EXAMINATION Wire AWG and smaller shall be factory color coded. 2.) connections t conduit bat ng�equipmenl t be suchliasdmotors 120/208 Volts 277/480 Volts (minimum 2'-0". maximum 6'-0"), connection to lay--in A. Verify field measurements and circuiting arrangements as shown type light fixtures, or in remodel areas specifically noted for on Drawings. Phase A — Block Phase A — Brown "fishing" In existing walls or non—accessible ceilings. Install Phase B — Red Phase B Orange conduit in accordance with Article 348 of the National B. Demolition Drawings are based upon field observation and existing Phase C — Blue Phase C — Yellow Electrical Code. record drawings. Report discrepancies to Architect/ Engineer Neutral — White Neutral — Gray before disturbing existing Installation. Ground — Green Ground — Green Switch Switch B. All exposed conduit (Including conduit Installed In ceiling plenums) shall be routed parallel or Travellers — Pink Travellers — Purple P ) P perpendicular to the 2.03 PREPARATION building walls. Support conduit as required by the National Electrical Code. W A. Provide temporary wires and connections to maintain existing 3.04 OUTLETS systems in service during construction. When work must C. Provide expansion type fittings for all conduits which cross 00 be performed on energized equipment or circuits, use personnel A. 4" square or octagonal, zinc coated sheet steel boxes. expansion joints. Z J a_ experienced in such operations. E: B. Provide 3/8" no—bolt fixture studs. 4.02 GROUNDING �W U 2.04 DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK V .J � r C. Provide covers set to come flush with finished walls. A. Distribution equipment, conduit systems, supports, cabinets, J W A. Extend existing installations using materials and methods equipment, transformers, fixtures, the grounded circuit conductor, Q Q O a specified. D. Utility or sectional switch boxes only where permitted. etc. shall be properly grounded in accordance with the latest O co edition of the National Electrical Code. Provide all bonding jumpers B. Where devices, switches, motor connections, etc. are to be 3.05 JUNCTION BOXES AND PULL BOXES and wire, grounding bushings, clamps, etc. as required for complete U L.1 removed from walls which are remaining, walls shall be patched grounding. Route ground Conductors to provide the shortest and ig after conductors have been removed. A. Locate pull boxes and junction boxes above accessible most direct path to the ground electrode system. Ground W W O to match original finish, W o Blonk coverplates over existing boxes are not acceptable. ceiling or In unfinished areas. connections shall have clean contact surfaces, tinned and sweated n/ N while bolting. Install all ground conductors in conduit. L.L 2.05 CLEANING AND REPAIR B. Support pull and junction boxes independent of conduit. � Q END OF SECTION W A. Clean and repair existing materials and equipment which remain W O 4 or are to be reused. J V E U J X J o, � � Q d � J r -C Q v 0 ri ELECTRICAL SPECIFICATIONS CD a DAM 12/12/2003 DRAIN BY CMP _d Q CHIM BY CMP N L SHEET FILE E4.0-DWG i COPYRIGHT 2003 BY DAMS PARTNERSHIP P.C.. ARCHITECTS I X SHM WAl U .� E400 ("1 �O D.P.A. PROJECT# 03942.00 o, _ PROM= XORM ALL BuLmm SHM SMW NAME REV. QIgE 1. DO NOT SCALE DRAWINGS. VAIL ALLEY MEDICAL CENTER APPLICAAE BULMS CODES : ARCHffENLW 2. IF DISCREPANCIES IN ARCHITECTURAL ELEMENTS (PARTITIONS, DOOR LOCATIONS... ETC) 181 MEADOW DR AO.0 GENERAL INFORMATION OCCUR BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, THE ARCHITECTURAL VAIL, COLORADO DRAWINGS SHALL GOVERN; ADVISE ARCHITECT PRIOR TO COMMENCING WORK. 1997 THE UNIFORM BUILDING CODE A1.0 DEMOLITION FLOOR AND CEILING PLAN � 1998 THE INTERNATIONAL MECHANICAL CODE A2.0 FLOOR AND CEILING PLAN 3. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME COMPLETELY FAMILIAR WITH ALL _ 1997 THE UNIFORM FIRE CODE A3.0 DETAILS OHS W& %%U EY MEOM CENW EXISTING CONDITIONS IN THE AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. 1994 THE UNIFORM PLUMBING CODE EDWARDS COLORADO 4. CONTRACTOR TO COORDINATE THE FOLLOWING WITH THE OWNER: PROJECT PHASING, SITE 1999 THE NATIONAL ELECTRIC CODE ACCESS, TEMPORARY UTILITIES AND OWNER INSTALLED EQUIPMENT. BRICK OONSTRUIDWN kt* A W SIC 5. THE CONTRACTOR SHALL NOTIFY THE OWNER 7 DAYS PRIOR TO COMMENCING WITH WORK_ 111.0 ELECTRICAL COVER SHEET CONIRACM P.O. BOX 8529 AVON, COLORADO 81620 6. THE CONTRACTOR SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE E2.0 ELECTRICAL PLANS CONTACT: TODD BERRY (303) 466-9665 MATERIALS AND DEBRIS THROUGHOUT THE ENTIRE BUILDING AREA. E3.0 ONE-LINE DIAGRAM AND LOAD JUSTIFICATIONS FAX (303) 466-9667 E4.0 ELECTRICAL SPECIFICATIONS 7. ALL INTERIOR ELEVATION DIMENSIONS ARE FINISHED DIMENSIONS, UNLESS OTHERWISE OCCUPANCY TYPE AND OONSIRUCWt NOTED. CONSTRUCTION MANAGER ARCHT= DAM P.O. The HCBo*Group OCCUPANCY CLASSIFICATION: 1-1.1 HOSPITAL (UBC TABLE 36 0225 MAIN ST., UNIT C101 8. GENERAL CONTRACTOR IS TO COORDINATE LEAD SHIELDING REQUIREMENTS AND PO BOX 8529 EDWARDS, COLORADO 81632 SPECIFICATIONS. LEAD SHIELDING IS TO BE INCORPORATED INTO GYPSUM WALL BOARD, Avon.Cdorado8182D CONTACT. SCOTT NEVIN, AIA (970) 926-8960 DOOR, DOOR FRAME, WINDOW, AND WINDOW FRAME PER SHIELDING ANALYSIS PROVIDED Qe TYPE F TR T N• TYPE I FIRE-RESISTIVE FAX (970) 926-8961 BY THE OWNER. 9. GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR THE FOLLOWING: 7 OONSULMM km A. GYPSUM WALLBOARD G ALLOWABLE FLOOR AREA: UNLIMITED (UBC TABLE 58 7350 E. PROGRESS PLACE, SUITE 100 B. LIGHTING AND ELECTRICAL DEVICES DAVIS PARTNERSHIP ARCHITECTS G ENGLEWOOD, CO 80111 C. DOORS. FRAMES, DOOR HARDWARE, WINDOW FRAME AND LEAD GLASS 0225 MAIN STREET.UNIT C101 E ALLOWABLE HEIGHT: UNLIMITED UBC TABLE 56 MECHANICAL AND ELECTRICAL CONTACT: CRAIG PERRY (303) 721-6600 D. ALL FINISHES INCLUDING FLOORING, CEILING TILE, RUBBER BASE AND PAINT_ EDWARDS,COLORADO 81632 Ov FAX (303) 721-0200 970.928.8960 F.970.926.8961 F- REFER TO ELECTRICAL FOR ADDITIONAL REQUESTED SHOP DRAWINGS. um FIRE 5UPPRESSION- u AUTOMATIC SPRINKLER SYSTEM 10. GENERAL CONTRACTOR IS TO COORDINATE EQUIPMENT DELIVERY AND ACCESS. NOT PROVIDED IN REMODELED ROOM DETECTORS AND ALARM SYSTEM TO REMAIN 11- GENERAL CONTRACTOR TO HAVE ARRANGEMENTS MADE FOR TEMPORARY STORAGE OF U RADIOLOGY EQUIPMENT. BC SECTION 904.2.2 ISSUEIREVISION DATE NO. 100% CDS 12/12/0 OCODE INFORMATION 10SHEETINDEX o PARTICIPANTS (D GENERAL NOTES 125 DOOR IDENTIFIER DETAIL IDENTIFIER 1 NoN-Ru►TEu PurTmoN wi I�r�n IJ�c� � 1 ADJ. ADJUSTABLE MIN. MINIMUM FULL--HEIGHT 39" METAL STUDS 0 16" O.C. _--:_ _ -" A1.1 A.F.F. ABOVE FINISH FLOOR MTL. METAL MAX. W/ ONE LAYER V TYPE 'X' GYPSUM -� .�::-z_= GYPSUM BOARD HARD WOOD OFFICE NEW ROOM ALUM. ALUMINUM O.C. ON CENTER P. PAINT BOARD EACH SIDE TO 4" ABOVE CEILING W/ =:__ .i:::___ VENEER PLYWOOD 125 IDENTIFIER CFT. CERAMIC FLOOR TILE PREV_ PREVIOUS LEAD LINING ON INTERIOR SIDE CONC. CONCRETE P. RE: SHIELDING ANALYSIS (BY OWNER) CONT. CONTINUOUS PV.LAM PLANK VINYL LAMINATE a _ CORR. CORRIDOR RE: A2.O, A3A CONCRETE BATT INSULATION STORAGE EXISTING ROOM 1 IDENTIFIER CPT-CPT_ CARPET RE: REFER R BASE ��pF A1.1 CWT. CERAMIC WALL TILE IDENTIFIER R.O. ROUGH OPENING DBL. DOUBLE S.F. SQUARE FEET I u n WON-RATED PARTITION PARTITION EA. DISPENSER HARD W000 S.S. STAINLESS STEEL STD. STANDARD I�E�lIµ WALL IDENTIFIER EA. EACH ELECTRIC * FULL–HEIGHT 2 Xi" METAL STUDS 0 16" Q.C. _---_ _----------_—_--- BY OWNER ELEV. ELEVATION STDS. STANDARDS 202N 5 j �/ MAX. W/ ONE LAYER V TYPE "X' GYPSUM EQ_ EQUAL STRUCT. STRUCTURE ALIGN FACE W/ OUTSIDE EQUIP. EQUIPMENT SUSP. SUSPENDED � BOARD WALL DUCTS E. (TYP_) TYPICAL � � O INTERIOR ID LUMBER INTERIOR EXT. EXTERIOR RE: SHIELDING ANALYSIS (BY OWNER) A1.1 1 ELEVATION EXIST- EXISTING TREAT. TREATMENT RE: A2.0, A3.0 REFERENCE – – GA. GAUGE U.N.O. UNLESS NOTED OTHERWISE GALV. GALVANIZED VCT. VINYL COMPOSITION TILE r GYP. BD. GYPSUM BOARD SV SHEET VINYL I 1• G.C. GENERAL CONTRACTOR l3 EXISTM LEAD LMW WALLS WOOD BLOCKING I I HPDL HIGH PRESSURE DECORATIVE LAMINATE VVMC VAIL VALLEY MEDICAL CENTER ENLARGED PLAN INSUL INSULATION W/ WITH O WINDOW IDENTIFIER I IDENTIFIER MECH. MECHANICAL W13. WOOD BASE GENERAL CONTRACTOR TO CONFIRM EXISTING WALLS I I WD. WOOD W COMPLY W/ NEW SHIELDING ANALYSIS PROVIDED BY THE OWNER PLYWOOD ` J F_ J co - -� Z — Lo DIMENSION LINE REFER TO 1/AZA FOR WALL TAGS W Q J W Co Q0 ao UD ❑ (DWALL � � 3:TYPES (DMATERIAL SYMBOLS (DSYMBOLS (DABBREVIATIONS ❑ W O W 1 C( � � � o Q J WO CC � Pffil f 9MPE Of WOMC LK G V DOOR AND FRAME SCHEDULE r- DOOR Q FRAME `-- SIZE I --- • W. IIIEADOw M MATL. ` MARK WD IHGT THK MATL. HARDWARE SET NO.1 NOTES r ' 001 4'-0-17'-0- 1 3/4-1 WD HM 1 1 LEAD LINED DOOR AND PIVOT FRAME RE: SHIELDING ANALYSIS BY OWNER; COLOR TO MATCH HALLWAY SCHEME s — I � GENERAL INFORMATION DOOR HARDWARE SET 1 : ; To 1 PIVOTSITT RDGSON pF-- FMT 1O VVMC 1 SIDE PIVOT KGON MIDI XW RM 1 PASSAGE SET LEAD LN3)INSIDE ROSE SCHLAGE 1 WAIL BLPAPER IVES DATE 12/12/2003 1 OVEW4EAD DOORSTOP GL DRAWN BY BJP 1 SMOKE SEAL PFANCO � RE: HARDWARE CONSULTANT: BOB EURICH, AHC <DEWiM CHK D BY SN SHEET FILE AO-O.dwg OOPYWGHr 2W3 BY DAMS PARrNERSW P:C.. ARCrr F8= SHEET NUMBER- AOOO DOOR AND FRAME SCHEDULE o KEYPLAN ® NOT TO SCALE o VICINITY MAP NOT TO SCALE D.P.A. PROJECT# 0&%2.00 N Al EXISTING PASS THROUGH TO REMAIN REMOVE EXISTING CONSOLE TURN OVER TO OWNER - DXISTING CIRCUIT BREAKER BOX TO REMAIN RE: ELEC. DEMO CONTROLLER TURN OVER TO OWNER REMOVE EXISTING PHONE MOUNT BOX AND ELEC. SURFACE MOUNTED CONDUIT DEMO WALL AND WINDOWS F = _ _ = ROOM FINISH SCHEDULE FOR NEW FLOORING G ON ENTERLiNE OF DOOR OPENING INSTRUCTION MANAGER The FICBedc Group RE 7/A3.0 NTROL RAD EXAM ROOM 1 PO BOX 8529 002 Arran,Colorado 81620 00 1 REMOVE EXISTING 4'-0' X 6'-8' HT. DOOR, FRAME AND HARDWARE J.� 1 ENLJjRGE OPENING TO ACCEPT A 4'-0' X 7'-O- HT. DOOR, FRAME AND HARDWARE i J 1 REMOVE EXISTING X-RAY WALL STAND TURN OVER TO OWNER DAVIS PARTNERSHIP ARCHITECTS 0225 MAIN STREET.UNrr C101 EDWARDS,COLORADO 81632 970.926.8960 F.970.928.8981 M 2'-9' ■ 7 DEMO EXISTING RUBBER BASE IN ENTIRE ROOM RE: ROOM FINISH SCHEDULE A3.0 1 1 ISSUE/REVISION DATE NO. REMOVE EXISTING X-RAY TABU 1 1 100% CDS 2/12/03 AND FLOOR MOUNTING BRACKET l 1 TURN OVER TO OWNER 1 1 CUT AND DEMO EXISTING CONCRETE SLAB FOR NEW TRENCH DUCT RE. 1/A3.0 AND COORDINATE W/ EQUIPMENT SHOP DRAWINGS BY G. E. EXISTING TRANSFORMER TO BE REMOVED RE: ELEC. TURN OVER TO OWNER 1 DEMOLITION FLOOR PLAN Ai0 v+' - r-4' SCOT�AICHAE4- NEViN 202985 v OFD ARG W ~ J 00 Z — L0 W Q co w OC 00 Qa 00 (.) o ❑ DEMO EXISTING X-RAY SUSPENSION ARM ❑ W O AND TURN OVER TO OWNER w DEMO EXISTING SMOKE DETECTOR D 0 ROL EXISnNG CONCRETE JOIST. TO REMAIN Q CON0_T 2 W_6 DEMO EXISTING 'N-USE' LIGHT FIELD VERIFY LAYOUT PRIOR TO w Q EP N U LATRUT SHOP DRAWINGS W J � IRAD LXAMI R00 I= R EXA ROOM 0o J � I I I 001 L j I EXISTING WALL SUPPLY DIFFUSER TO REMAIN r I I I I I I I > 00 Q Fr- , I I I I I REUSE EXISTING UNISIRUT IF POSSIBLE - 1 ,r. 1 DEMO EXISTING EQUIPMENT STATIONARY RAILS L J &D. AND TURN OVER TO OWNER I I I I I I OTHERWISE DEMO —1 — I— I — I— t RE: 3/A3.0 I L I I I _ _ _ -I _ I_ J-I - 1 DEMO EXISTING CABLE DRAPE RAIL I I I I I I SAVE FOR POSSIBLE REUSE r i I I I I I I ! I I I I DEMO EXISTING LIGHTS DEMOLITION PLANS RE_ ELEC. r IL L J DATE 12/12/2003 DRAWN BY 8JP CHK'D BY SN SHEET FILE A0-0.dwg 2 DEMOLITION CEILING PLAN 3 DEMOLITION ABOVE CEILING PLAN COPYNGW "0 BY [NkM PARTNUM4P P.C-. ►rC+FIECTS A1.0 U4' ■ r-O' A10 ;47- T-0' SFFEf NUMBER: Al ■ D.P.A. PROJECT# 03942.00 LEAD LINED WINDOW RE SHIELDING ANALYSIS (BY OWNER) i i EXISTING CIRCUIT BRFAIIER BOX TO REMAIN RE: ELEC_ ROTEUS OPERATORS CONSOLE PROVIDE NEW PHONE WALL M(mJNTED BY G.E. CONCEAL WIRE IN WALL_ 24 GAUGE BACKING RE ELEC. BEHIND GYPSUM BOARD RE: INTERIOR ELEVATION 4'-0" x 7'-0" x 1 3/4" LEAD LINED DOOR RE A3.0 Z NEW FLOOR MOUNTING BRACKETS FOR PROTEUS X-RAY TABLE BY G.E. CONSTRUCTION MANAGER CONTR L The HC N*Group �! ,•�D 3 PO BOX 6529 ¢ 002 PROTEUS X-RAY TABLE BY G.E. Avon.CokmWo 81620 3 X55 001 z FURR OUT WALL FOR FLUSH FIT i W/ WALL. DUCTS AND MAIN DISCONNECT RE: 4 5 A3.0, ELEC. AND G. E. SHOP DRAWINGS 3 RAD EXAM ROOM DAVIS PARTNERSHIP ARCHITECTS ISTI DO 1 ®WAIiDs,COLORADO 816321 R ao � 970.926.8960 F.970.928.8961 X 2'-9' 2 � ? X-RAY WALL STAND BY G.E. C-4 3 24 GAUGE BACKING BEHIND UM BOARD EXISTING 4' X 4' WALL DUCT r- W :�, rt GYPS RE: 3/A3.0 ISSUVREVISION DATE NO. S 0 2 1 `i' 100% CDS 2/12/03 ;n Ln It a o NEW X-RAY GENERATOR FLOOR MOUNTED BY G. E 2.-9w � Ar—�w 3" EXISTING 7 NEW CONCRETE FLOOR TRENCH TO ACCEPT 12" X 3" TRENCH DUCT EXISTING ONE OF THE FOLLOWING MUST BE INSTALLED FOR GE INSITE CONNECTION BASED UPON SYSTEM CONFIGURATION A (1) INTERNET ACCESSIBLE VIRTI AL PRNVATE NETWORK WITH A STATIC IP ADDRESS AND (1) TELEPHONE LINE - DEDICATED DIRECT-DIALING, VOICE GRADE B. (2) TELEPHONE LINES - (1) DEDICATED DIRECT-DISTANCE-DIALING, VOICE GRADE AND (1) A DEDICATED DATA LINE RE ELEC. AND G. E. SHOP DRAWINGS 1 FLOOR PLAN A20 V4• - r-O' CIO r SCOTT M;CHAEL NEViN 202985 v DA w ~ J 00 Z Lf) w co V i V� 2 X 4 ARMSTRONG SECOND LOOK CEILING TILE J w co W/ I(is STANDARD WHITE CEILING GRID � ❑ ❑ O 6w 6w 6' sw V 0 ❑ SMOKE DETECTOR O 1'-7" 1`-N3" 2'-6' 2'-6' 2'-6' 2'-6' RE ELEC. ❑ w o NEW )(F RADIOGRAPHIC SUSPENSION WITH INBOARD MOUNTING. w w ❑ O INSTALLED BY G. E. COORDINATE W/ GENERAL CONTRACTOR J Q C TRO EXISTING CONCRETE JOIST. TO REMAIN � � w ?nI NEW 'IN-USE' LIGHT ABOVE 02 RA EXAM ROOM FIELD VERIFY LAYOUT PRIOR TO Q O S D ADA XAM RE_ ELEC. AND G. E. SHOP DRAWINGS PREPARING UNISTRUT SHOP DRAWINGS w 001 V O 0 0131 LIGHTS TV?. W:51 RE: ELEC. J X '� J ISTING WALL SUPPLY DIFFUSER TO REMAIN ` r GENERAL CONTRACTOR TO CLEAN / 0 O DIMENSIONS PROVIDED TO SHOW J r DIFFERENCE BETWEEN EXISTING STRUCTURE AND NEW UNISTRUT LAYOUT LONGITUDINAL NEW STATIONARY RAIL FOR XT SUSPENSION REQUIRED BY G. E_ F1 INSTALLED BY G. E COORDINATE W GENERAL CONTRACTOR NEW UNISTRUT OR REUSE EXISTING UNISTRUT. � / UNISTRUT SUPPORT CAPACITY INCLUDING ANCHORAGE IS TO BE COORDINATED W/ G. E. AND A LETTER IS ^ ^ TO BE PROVIDED NOTING EXISTING STRUCTURE CAN V V SUPPORT NEW EQUIPMENT'S STATIC AND DYNAMIC LOADS PLANS N r w s s 21-2' 2'-2' 2'-2' 2'-2" 2'-2' a SUPPORT REQUIREMENT PROVIDED BY 2' DATE 12/12/2003 REUSE EXISTING CABLE DRAPE RAIL IF POSSIBLE EQUIPMENT SUPPLIER (G. E_) DRAWN BY BJP RAIL PRONDED BY GENERAL CONTRACTOR CHK'D BY SN SHEET FILE AO-O.dwg 2 CEILING PLAN 3 ABOVE CEILING PLAN °°""T 2M Ff WIS PARTNOMP P.C, ARCHNEC'T$ Ax.O ve - r-w A20 ve - T-0' Sir NUMBER: A200 D.P.A. PROJECT# 03942.00 ROOM FINISH SCHEDULE EXISTING SLAB BASE Wmis CEILING NEW SLAB TO MATCH ROOM NO ROOM NAME FLOOR BASE MAT. COLOR N S E I W MATL HEIGHT 001 RW EMM ROOM VCT 1 RB 1 PT 1 Pf i Pr 2 Pf 1 CLNG 1 II EXISTING W/ 002 CONTROL VCT 1 Re 1 PT 1 Pi 1 PT 2 PT 1 CLNG 1 s'-r FIBERMESH TO MATCH EXISTING 12` x 3" TRENCH DUCT BY G. L RUBBER BASE: ROPPE; COLOR 1= P172 CHAMPAGNE VCT 1 = MANNINGTON #407 2�—g. PT 1 = SHERMAN WILLIAMS PAINT SW 1116 VELLUM PT 2 = SHERMAN WILLIAMS PAINT WS 1188 BURMESE JADITE CLNG 1 = ARMSTRONG SECOND LOOK W/ 2 X 2 LOOK, 1%16" GENERAL NOTE: ALL NEW AND EXISTING WALL DUCT TO BE PAINTED TO MATCH ADJACENT WALL • f - F 4 , -4 A 4 v - - I � 4 •y 1 - z _ - 4 CONSTRUCTION MANAGER a The HCBe&Group PO BOX 8529 Arran,Colorado 81620 0 1/2`Oxl'-0" FLOOR DUCT TO BE FLUSH DOWELS AT 12" W/ FINISHED FLOOR, DAVIS PARTNERSHIP ARCHITECTS O.C-. DRILL AND GROUT AS REQUIRED 0225 MAIN STREET.UNIT C101 EPDXY 5- MIN. INTO EDWARDS,COLORADO 81632 6 EXISTING SLAB 970.92629BD F.970.926.8961 3 A3.0 5 DO NOT UNDERMINE EDGE OF EXISTING SLAB 4 ISSUEIRE111SION DATE NO. ❑ 1 DETAIL AS.O 1 V2' - T-w 100% CDS 2/92/03 0 0 2 KEY PLAN AND FINISH SCHEDULE A3 D 1/4' + f-W NEW 10" X 3 1/2- SURFACE WALL DUCT EXISTING 4" X 4" SURFACE WALL DUCT EXISTING CIRCUIT BREAKER SCOTT MICHAEL #, EW PROTEUS GENERATOR BOX TO REMAIN NEVIN BY G. E I RE: ELEC. NEW PHONE 2029$5 NEW PROTEUS GENERATOR " EXISTING PASS THROUGH RE ELEC_ fL �� gY G. E. EXISTING 4 X 4 1 O 24 GAUGE STEEL SHEET KING TO REMAIN NSFO ARG� I SURFACE DUCT / ATTACH TO STEEL STUDS UNDER GYPSUM BOARD vo NEW 10" X 3 1/2" SURFACE WALL DUCT NEW PROTEUS WALL BY G. E \ Q� NEW 1 1/2' DIA. CHASE PPLE FF \ 'i' COVERPLAW N l.Ll 1 7'-8- 1- N j co EW PHONE AND NETWORK CONNECTION W/ Z �.0 NEW 12" X 3" TRENCH DUCT TO VERT. TO ABOVE FINISHED CEILING PROVIDE (2) 16 GAUGE STEEL STUDS W Q Lo EACH SIDE OF DOOR JAMB TO STRUCTURE co J W Ix oo Q ❑ 00 L) O ❑ 3 INTERIOR ELEVATION 4 INTERIOR ELEVATION 5 INTERIOR ELEVATION 6 INTERIOR ELEVATION 0 2 0 A30 114' - T-0' A&O 1/4' -'r-0 A9A V4' - T-0' ASA 1/4• - T-0' W 111 0 00 �.. Q J �- w 0 w � U J J NEW EMERGENCY OFF SWffCH Q r W II:1 * 3'�' II:2-4f J r 4'-0" 2'-6" Q 11 A3.0 \ _ o \ LEAD LINED FRAME N m RE: SHIELDING ANALYSIS ° BY OWNER o z ,� - VERIFY DIM. W/ C.D ° - FL°0R PL""' TYP. INTERIOR ELEVATIONS e VERIFY DIM. W/ �- `° FLOOR PLAN, TYP. .y ,.� & DETAILS L 16 GAUGE STL NEW 2 1/2" DIA CHASE NIPPLE STAINLESS STEEL, TYPE 430, 16 GAUGE 14Y7 FLANGE AND COVERPLATE KICKPLATE W/ L-BEND AT DOOR EDGES LEAD SHIELDING ANCHORAGE, " RE: SHIELDING ANALYSIS LEADED GLASS LEAD LINED DATE 92/12/2003 6 X 6 X 4 BOX BY OWNER RE: SHIELDING ANALYSIS RE: SHIELDING ANALYSIS BY OWNER BY OWNER DRAWN BY BJP NEW PROTEUS OPERATOR'S CONSOLE CHK'D BY SN CONTROL SIDE RADIOLOGY ROOM SIDE 24 GAUGE SHEET BACKING IN WALL SHEET FILE AO—O.dwg COPYRIGHT 2003 B1f EaAV15 PARTNERSHIP PAC., ARCHRECIS 7 INTERIOR ELEVATION 8 DOOR ELEVATION - 001 8 WINDOW ELEVATION 10 DOOR JAMB DETAIL 11 WINDOW JAMB DETAIL SHEET NUMBER: AS.D 1/4' - T-0' AS.O V4' - T-M AS.O V4' - r-a V2' - 1-0* A3 O 1 V2' - T=0' ■ D.P.A. PROJECT# 03942.00 ® ® _GENERAL NOT_ES.,(FOR ALL_ELECTRICAL SHEETS NOTE; ALL SYMBOLS SHOWN ON LEGEND ELECTRICAL LEGEND ARE NOT NECESSARILY USED. 1. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. LIGHIING SCHEMATIC WIRING GRAPHICS 2. ALL 12DV BRANCH CIRCUITS SHALL BE 3—WIRE (PHASE,NEUTRAL,GROUND). PHASE, MKK C ENGINEERS INC . NEUTRAL, AND GROUND CONDUCTORS SHALL BE SIZE 12 AWG UNLESS OTHERWISE 9 0 DOWNLIGHT ® METER - _ - NOTED. 04 WALL MOUNTED FLUORESCENT OR INCANDESCENT �I! GROUND CONNECTION AS NOTED Mechanical, Electrical & Energy Consultants 3. REFER TO ARCHITECTURAL PLANS, ELEVATIONS AND DIAGRAMS FOR LOCATIONS OF LUMINAIRE, AS NOTED --� DISCONNECT SWITCH FLOOR AND WALL DEVICES. LOCATION WILL INDICATE VERTICAL AND/ OR HORIZONTAL MOUNTING. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE POWER FUSES MOUNTED LONG AXIS HORIZONTAL AT +18" AFF TO CENTER. 7350 East Progress Place, Suite 100 STRAIGHT BLADE DUPLEX RECEPTACLE MAGNETIC MOTOR STARTER Englewood, Colorado 801 i 1 CONSTRUCTION MANAGE g 4. PROVIDE TYPED UPDATED PANEL DIRECTORIES FOR ALL EXISTING PANELS AFFECTED The HCBm*Group ❑J JUNCTION BOX, AS NOTED �— CIRCUIT BREAKER, MOLDED—CASE, (303) 721-6600 BY REMODEL WORK, PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS PO BOX 8529 QJ OUTLET BOX THERMAL—MAGNETIC www.mkkeng.com REQUIRED. Avon,Colmado$1620 QJ 4 WALL MOUNTED OUTLET BOX -�-- ENCLOSED CIRCUIT BREAKER, MOLDED—CASE, 5. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS 0 ENCLOSED CIRCUIT BREAKER, MOLDED—CASE, THERMAL—MAGNETIC 500 West 18th Street, Suite 200 7535 Hilltop Circle AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS THERMAL—MAGNETIC Cheyenne, Wyoming 82001 Denver, Colorado 80221 WOULD ALLOW, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, ENCLOSED FUSED DISCONNECT SWITCH (307) 634-7647 (303) 428-8808 PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF REMODEL WORK DAVIS PARTNERSHIP ARCHI ECTS .o—# CONNECTION TO PRE—WIRED EQUIPMENT REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE 0225 MAIN STREET.UNIT C101 BREAKER PANEL POWER 'TRANSFORMER NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT EDWARDS.COLORADO 816332 827 Rood Avenue 10815 David Taylor Drive, Suite 170 DOCUMENTS. 970.926.8980 F.970.926.8961 SS TRANSIENT VOLTAGE SURGE SUPPRESSOR CURRENT TRANSFORMER Grand Junction, Colorado 81501 Charlotte, North Carolina 28262 a TRANSFORMER Q AMMETER (970) 245-3177 (704) 717-9950 6. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER PRIOR TO ROUGH—INS, VOLT METER COORDINATE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL ELEVATIONS, 175 N. 27th St., Suite 902 CASEWORK SHOP DRAWINGS AND EQUIPMENT INSTALLATION DRAWINGS. COORDINATE CIRCUITING TRANSFER SWITCH Billings, Montana 59101 LOCATION OF LUMINAIRES WITH ARCHITECTURAL REFLECTED CEILING PLANS. CONDUIT RUN L- GROUND FAULT PROTECTION ® (406) 256-1141 ® 7. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE ISSUE/REVISION DATE NO. ! CIRCUIT HOMERUN TO PANEL OR CABINET, CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. NO. OF ARROWS INDICATE NO. OF CIRCUITS FOR PERIMIT 2/12/03 G GENERATOR 8. PROVIDE (1) 3/4"C WITH BUSHING AND PULL WIRE FROM EACH TELEPHONE, DATA OR COMMUNICATION OUTLET SHOWN, TO ABOVE ACCESSIBLE CEILING. V WALL MOUNTED TELEPHONE OUTLET 3 MOTOR, NUMBER INDICATES HORSEPOWER 9, ALL ITEMS SHOWN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. ALL ITEMS SHOWN HEAVY LINE WEIGHT ARE NEW, OR RELOCATED AS WALL MOUNTED DATA OUTLET NOTED. Q WALL MOUNTED COMBINATION TELEPHONE/DATA SWITCHING ABBREVIATIONS 10. ON DEMOLITION PLANS, ALL ITEMS SHOWN HEAVY LINE WEIGHT SHALL BE REMOVED, OUTLET BOX S WALL MOUNTED SWITCH UNLESS OTHERWISE NOTED. ALL ITEMS SHOWN LIGHT LINE WEIGHT ARE EXISTING TO Q Q'I CEILING OR WALL MOUNTED SPEAKER REMAIN, UNLESS OTHERWISE NOTED. SUBSCRIPTS; NOTE; ALL ABBREVIATIONS SHOWN FIRE ALARM SYSTEM D = DIMMER ARE NOT NECESSARILY USED. 11. MAINTAIN CIRCUIT CONTINUITY FOR ALL EXISTING ITEMS THAT ARE REMAINING OR ® ®'I CEILING OR WALL MOUNTED DETECTOR BEING RELOCATED. AC -- ABOVE COUNTER AFC — ABOVE FINISHED CEILING 12, ALL NEW WIRING REQUIRED IN REMODELED AREAS SHALL BE FISHED THROUGH AFF — ABOVE FINISHED FLOOR EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS. SURFACE AFG — ABOVE FINISHED GRADE MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS. CONTRACTOR AIC — AMPS INTERRUPTING CURRENT SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS NOTED TO DO SO. AL — ALUMINUM CB — CIRCUIT BREAKER 13. ALL ITEMS SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY CU — COPPER INCLUDING ALL ASSOCIATED CONDUIT AND WARE BACK TO POINT OF ORIGIN OR DF — DEMAND FACTOR NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS OTHERWISE NOTED. WHERE �1 + EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM EST — ESTIMATED WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FLA — FULL LOAD AMPS FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK COVERPLATES OVER GFI — GROUND FAULT INTERRUPTER EXISTING BOXES ARE NOT ACCEPTABLE. IF EXISTING CONDUITS ARE ROUTED IN : 37276 MCA — MINIMUM CIRCUIT AMPS CONCRETE FLOOR SLABS, WALLS OR CEILINGS, THEY SHALL BE CUT BACK TO WITHIN MCB — MAIN CIRCUIT BREAKER CONCRETE AND FILLED WITH GROUT'TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH MLO — MAIN LUGS ONLY WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. AG NC — NORMALLY CLOSED 14, PROVIDE 1/4" TAPE LABELS ON ALL RECEPTACLES AND SWITCHES THAT �(CON'J11lT1IG NIC — NOT IN CONTRACT INDICATES PANELBOARD AND CIRCUIT NUMBER. LABELS SHALL BE BLACK NO — NORMALLY OPEN LETTERS ON WHITE OR CLEAR BACKGROUND. NTS — NOT TO SCALE OC — OVER CURRENT 15. COORDINATE INSTALLATION OF COMMUNICATION CABLING, TERMINATIONS, AND OL — OVERLOAD DEVICES WITH HOSPITAL, PF — POWER FACTOR 16. WORK UNDER THIS CONTRACT IS IN OCCUPIED SPACES AND EQUIPMENT ROOMS. W SC — SHORT CIRCUIT CONTRACTOR SHALL SCHEDULE AND COORDINATE WORK AND ANY EXISTING VVMC — VAIL VALLEY MEDICAL CENTER EQUIPMENT DOWNTIME WITH THE OWNER. ALL WORK OUTSIDE CONSTRUCTION J XFMR — TRANSFORMER BARRIERS SHALL BE DONE DURING OFF OR WEEKEND HOURS. Z -- L 17. ALL RECEPTACLES IN PATIENT CARE AREAS AS DEFINED IN NEC 517.2 SHALL rW, C0 U BE HOSPITAL GRADE. U J r J W co 18. THE ELECTRICAL CONTRACTOR SHALL MAINTAIN FIRE RATINGS FOR ALL CONDUIT PENETRATIONS THROUGH FIRE RATED CONSTRUCTION. ❑ ❑ oCL .o ru 19. ALL CONDUIT AND WIRE SHALL BE CONCEALED EXCEPT IN ELECTRICAL ROOMS. ❑ LO N 20. ALL NEW AND RELOCATED LUMINAIRES SHALL BE SUPPORTED INDEPENDENTLY 6 OF CEILING SUPPORT HANGERS, IN COMPLIANCE WITH UBC REQUIREMENTS w w o CD OC ❑ Q c°u 21. ALT. ABANDONED WIRING SHALL BE REMOVED FROM DUCTS OR CONDUIT. J 22. ALL FLOOR PENETRATIONS SHALL BE X—RAYED AND THE X—RAYS INSPECTED AND W a APPROVED BY THE OWNER PRIOR TO DRILLING OR CORING. ALL PENETRATIONS W o s SHALL BE FIRE--PROOFED. ANY PENETRATION LARGER THAN 1/2 SHALL BE G U a CORE—DRILLED. J F U X J a T d J r � L _ F- a 0 CD a 3 ELECTRICAL CS COVER SHEET W N (7� 3 A C DATE 12/12/2003 a U DRAWN W CHIP d a CHK'D BY CIMP a T SHEET FILE E1.0.13 MiG 6 COPYRIGHT 2003 BY DAMS PARTNERSHIP P.C., ARCHITECTS X SHIET M111M U El 7 ■ / D.P.A. PROJECT# 03942.00 a / QENERALNOTES: COD 1. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OWNER AND WITH GE MEDICAL SYSTEMS INSTALLATION DRAWINGS PRIOR TO ROUGH-INS. 2 2. ALL CONDUIT AND DUCT RUNS SHALL HAVE LONG SWEEP BENDS. 3. CONDUITS AND DUCT INSTALLED ABOVE CEILING OR BELOW FLOOR MUST BE INSTALLED AS NEAR TO CEILING OR FLOOR AS POSSIBLE o TO REDUCE RUN LENGTH. i I I I CONSTRUCTION MANAGER { I I I I 4. ALL DUCTWORK SHALL BE CERTIFlED/ItATED FOR ELECTRICAL POWER TheHCBedcOroup PURPOSES AND SHALL BE ELECTRICALLY AND MECHANICALLY PO BOX 8 BONDED TOGETHER IN AN APPROVED MANNER. Avon,Colorado 81620 I 4 i• j 6. ALL AIRES SPECIFIED SHALL BE STRANDED, FLEXIBLE, l'FIHN/THWN, (TYP. ' I I COLOR-CODED, COPPER ONLY, CUT 10'-Cr LONG AT OUTLET BOXES, DUCT TERMINATION POINTS OR STUBBED CONDUIT ENDS, UNLESS - OTHERWISE NOTED. ALL CONDUCTORS, POWER, SIGNAL AND GROUND, DAVIS PARTNERSHIP ARCHITECTS € - I MUST BE RUN IN CONDUIT OR DUCT SYSTEM. RING OUT AND TAG i I I 0225 MAIN STREET.UNIT C101 - - - - - - - - I ALL WIRES AT BOTH ENDS. WIRE RUNS MUST BE CONTINUOUS AND EDWARDS.COLORADO 81682 FREE FROM SPLICES. 970.926.8980 F.970.926.8961 Li I I I I z Ld f E L� J I 7, ROUTING OF CABLE DUCTWORK, CONDUITS, ETC., OTHER THAN C) ¢ SHOWN ON THIS DRAWING MAY RESULT IN THE NEED FOR GREATER Of c-> , THAN STANDARD CABLE LENGTHS (REFER TO GE MEDICAL SYSTEMS - - - - - - - 0­0 DRAWINGS FOR MAXIMUM USABLE LENGTHS POINT TO POINT. I ' ISSUEIREVISION DATE NO. ' I I I 3 FOR PERMR 2/12/03 I +54" ❑ �-❑-_ ❑ FLAG NOTES THIS SHEET: O 3 1. EXISTING DISTRIBUTION PANEL "DHA" IS LOCATED IN THE EAST MAIN ELECTRICAL ROOM, REFER TO "SECOND FLOOR KEY PLAN", THIS (1 TO "DHA" SHEET FOR ROOM LOCATION. 2. REMOVE EXISTING WARNING LIGHT. PROTECT EXISTING 120V BRANCH CIRCUIT FOR REUSE UNDER NEW WORK. REFER TO "X—RAY ROOM POWER AND SYSTEMS PLAN". THIS SHEET, FOR MORE INFORMATION. NORTH _ V I E W G DARK R M 3. NEW WARNING LIGHT. CONNECT TO EXISTING 120V BRANCH CIRCUIT. X-RAY ROOM LIGHTING PLAN_, SCALE: 1/8" w 1'-0" 4. PROVIDE 11" SQUARE. RECESSED INCANDESCENT DOWNLIGHTS WITH 8' 0 8' 16' NOR]3j TEMPERED PRISMATIC LENS AND REGRESSED WHITE DOOR, LITHONIA 1t,�� „� Y ROOM POWER AND SYSTEMS PLAN I�-11RWII—T73. OR ENGINEER—APPROVED EQUAL. PROVIDE {1} 100W — A-19 LAMP FOR EACH LUMINAIRE. SCALE' 1/4* = 1'-0" 5. REMOVE EXISTING CIRCUIT BREAKER. PROTECT EXISTING ENCLOSURE 4 0 4 8 FOR REUSE UNDER NEW WORK. REFER TO "X-RAY ROOM POWER AND SYSTEMS PLAN". THIS SHEET, FOR MORE INFORMATION, �r' l 6. PROVIDE 150OW. WHITE. SLIDE—TO—OFF DIMMER SWITCH, LUTRON &•;y jme* • ONT-1500—WH. OR ENGINEER—APPROVED EQUAL. 7. REMOVE EXISTING SMOKE DETECTOR AND REINSTALL ON NEW CEILING. 3726 EXTEND EXISTING FIRE ALARM CIRCUITRY AS NECESSARY. 8. REMOVE EXISTING LUMINAIRE. PROTECT EXISTING 120V NORMAL SNNAL LIGHTING BRANCH CIRCUIT ORIGINATING FROM PANEL "L1 A" LOCATED ELECTRICAL LEGEND IN CORRIDOR APPROXIMATELY 75' WEST OF THE X-RAY ROOM. 9. CONNECT TO EXISTING LOCAL 120V NORM_AL LIGHTING BRANCH WREWAY CIRCUIT ORIGINATING FROM PANEL "L1A". PRIOR TO NEW WORK. Q DESCRIPTION ELECTRICAL HARDWARE VERIFY WITH AMMETER THAT THE BRANCH CIRCUIT DOES NOT EXCEED 6.0 AMPERES WITH ALL LOADS SWITCHED ON. A MAIN DISCONNECT PROVIDE NEW 7OA3P, 48OV, 30, 14,000AIC, RECESSED, ENCLOSED MOLDED-CASE CIRCUIT BREAKER. ------ MOUNT IN EXISTING CIRCUIT BREAKER ENCLOSURE. O ' DLK1 DOOR SWITCH PROVIDE NORMALLY OPEN 24V DC SAFETY DOOR INTERLOCK LIMIT SWITCH. THE ROOM DOOR SHALL BE CLOSED TO ALLOW X-RAY OPERATION. MOUNT +6'-6" AFF TO CENTER. Z Lo Lo a 0 K CASSETTE HOLDER PROVIDE 6"X6"X4" DEEP PULLBOX WITH 1-1/2" DIAMETER CHASE NIPPLE AND COVERPLATE. MOUNT W Q u I FLUSH IN WALL +2'-3" AFF TO CENTER. J OC CONTROL CONSOLE PROVIDE 6"X6"X4" DEEP PULLBOX WITH 2-1/2- DIAMETER CHASE NIPPLE AND COVERPLATE. MOUNT w co FLUSH IN WALL +1'-6* AFF TO CENTER. v I PT TABLE PROVIDE (2) 1-1/4" DIAMETER SHORT NIPPLES WITH BUSHINGS AND LOCKNUTS. ❑ ❑ O cu — � c�u I 0 XG GENERATOR PROVIDE 32" OF GROMMET MATERIAL FOR AN 8"X8" OPENING IN DUCT COVER. PROVIDE 6'-0" OF ❑ 1-1/2 FLEXIBLE METAL CONDUIT, AND (2) 1-1/2 90 DEGREE CONNECTORS, X-RAY ( I ri ROOM w w . 09 C3 XRL1 WARNING LIGHT PROVIDE PRESCOLITE #EX1R "X-RAY ON" INCANDESCENT LUMINAIRE, OR ENGINEER-APPROVED EQUAL. 100 (u 24V, 8A OR LESS LOW VOLTAGE SOURCE. MOUNT 6" ABOVE DOOR. J -r- XTS1 X—RAY TUBE HANGER PROVIDE 32" OF GROMMET MATERIAL FOR AN 8"X8" OPENING IN DUCT COVER. W ' a - _- _ w 0 SWD-1 SURFACE WALL DUCT PROVIDE 10"X3-1/2" SURFACE WALL DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS. J _ ' SURFACE MOUNT +0'-9" AFF TO CENTER. J a ' O u - FA PROVIDE 10-X3-1/2- RFA W � J SWD 2 SURFACE WALL DUCT 0 DE SURFACE ALL DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS. - SURFACE MOUNT FROM FINISHED FLOOR TO +1'-0" ABOVE FINISHED CEILING. • • ■ " . s Co Q SWD-3 SURFACE WALL DUCT EXISTING 4"X4" SURFACE WALL DUCT. - - J r L 5 C' _ TD TRENCH DUCT PROVIDE 12"X3" TRENCH DUCT WITH DIVIDERS AND REMOVABLE, ACCESSIBLE COVERS. NORTH MOUNT FLUSH IN FLOOR. _FIRST FLOOR KEY PLAN NO SCALE 0 a NORTH CD X-RAY ROOM ELECTRICAL DEMOU71ON PLAN FEEDER SCHEDULE ELECTRICAL SCALE: 1/8" V-0" $� 0 8' 16' WIRE AND CONDUIT SIZE EAST MAIN PLANS i ELECTRICAL 1 2-1/2"C WITH PULLWIRE ROOM 3 A 2 (2#12+#12G)1/2"C r DATE 12/12/2003 a i r ■ 3 {44+ 1/OG)1-1/4"C - DRAWN BY CMP d - a 4 (3#4+#1/OG)1-1/4"C - CHK'D BY CMP w w SHEET FILE E2.0.DWG d CAPYRIGFff 203 BY OVIVIS PAKfNERSHIP P.C. ARCHITECTS E " X omw M1� U NORTH ('7 SECOND &QOR KEY PLAN ■ NO SCALE D.P.A. PROJECT# 03942.00 o� i LOAD JUSTIFICATION FOR MAIN DIST. PANEL "DHA" PEAK LOAD REPORTED OVER LAST 12 MONTHS AS REPORTED BY HOLY CROSS ENERGY: 260.0 KW (AUGUST 2003) = 305.9 KVA (O 85X PF) X 125X = 382.3 KVA CONSTRUCTION C ER DEMAND LOAD REMOVED: PO BOX 8529 OLD X-RAY UNIT EST.) - 18.0 KVA X 1 DOX - 18.0 KVA Avon,Colorado 81620 FROM PANEL "L1A (LIGHTING) - 0.8 KVA X 125X - 1.0 KVA WO KVA LOAD JUSTIFICATION FOR PANEL_.._9vLJA TOTAL DEMAND LOAD REMOVED: _ 100A, 120/208V, 30, 4W DEMAND LOAD ADDED: NEW X-RAY UNIT = 48.5 KVA X 1 DOX = 48.5 KVA DAVIS PARTNERSHIP ARCHITECTS DEMAND LOAD REMOVED: D F TO PANEL "L1 A" (LIGHTING) = 1.1 KVA X 125X = 1.4 KVA 0225 MAIN STREET. UNIT C101 E.D. RENOVATION PROJECT, TOTAL DEMAND LOAD ADDED: - 49.9 KVA EDWARDS,COLORADO 81632 ISSUED 10-3-03, REVISED 11-7--03 = 2156 VA X 100X = 2156 VA 970.926.8960 F.970.926.8961 LIGHTING - 800 VA X 125X - 1000 VA NET DEMAND LOAD ADDED: 30.9 KVA TOTAL DEMAND LOAD REMOVED: - 3156 V TOTAL DEMAND LOAD: = 413.2 KVA DEMAND LOAD ADDED: LIGHTING = 1100 VA X 1253E - 1375 VA MAIN DISTRIBUTION PANEL CAPACITY: NET DEMAND LOAD REMOVED: = 1781 VA 2000A FUSES IN MAIN DISCONNECT SWITCH - 1662.8 KVA ISSUE/REVISION DATE NO. FOR PERMIT 12/12/03 FLAG NOTES THIS SHEET-. 0 1. REUSE EXISTING SPARE FUSED SWITCH. PROVIDE NEW FUSES AS INDICATED. O "L1 A" "L1 A1" 2. REMOVE EXISTING CIRCUIT BREAKER AND FEEDER BACK TO SOURCE. X-RAY 3. SHORT CIRCUIT VALUES BASED ON 500KVA UTILITY TRANSFORMER WITH RM B IMPEDANCE Z^1.5X. DIP 00A 60A3P TO .'�111E►�'0• TO TO "LPC"/ TO FLASH M TO " TO "TO" TO 37276 "P1" 4 "PP1" "LPD" ATS-2 STERILIZER MCC ATS-3 LPL ATS-1 90.IZ`I�-03•� �SSronJnt - - _ - � - - � � - � 400A 1000A 600A 200A 600A 40A 100A 100A 100A 150A 175A 175A 300A I J�J14 JJN JJN JJN JJN I I I FRN FRN FRN FRN FRN FRN FRN FRN I 400A 1200A 600A 400A 600A 60A 100A 100A 100A 100A 100A 200A 200A 200A 400A 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P I I FACE I { SPARE SPARE I W £ 120/208V.� 3�P 4W. 3000A 1 0%208V ON PANEL "�P" W 30, 4W. 1000A 100,000 AIC J r j W ao CL 0 V ❑ u AMU COND. ""` cv "PG- UNIT (ROOF) "PG- "PG- ❑ W da O BL1 A1" NEW BH1 A" CT OHM" 1 N RF M X-RAY SCAN �y ❑ O ROOM 125A RM B TO 125A3P J AMBULANCE FRS-R 70A L BUILDING 200A 3P BL1 A W 0 FEEDERS 100A3P ' 3 225A3P 120DA W V E 2ISE LIEBERT MCB MCB 3P GFI -J FUSES INTERCEPTOR MCB SHORT CIRCUIT SCHEDULE J x J A TVSS 250A 2 LPS 3 3 � SS #8G 400A3P X SHORT CIRCUIT CURRENT 0 in 30KVA, 45KVA, 75KVA. #2G J L 480- 480-- 480- 1 4 G94A = 208V. - 208V. = 208V. - 30,4W 30.4W 30,4W 500KVA, 2 36,487A 480-120/ 3 11,073A 500 KVA 100A MOLL CROSS 6 2 208V.30.4W HOLY CROSS FUSES SECONDARY 100A 277/480V NXFMR 3P r ONE-LINE DIAGRAM 1200A 60A 45A 70A 70A 2oaA 110A 125A 1200A 750A FEEDER SCHEDULE (SERVICE= 2R) ! I I o S FUSES FUSES FUSES FRS-R FUSES LPS LPS LIDS FUSES I AND LOAD W 30ooA 20O A 2DOA 60A IOOA 100A 100A 2DOA 100A 200A 200A 1200A 1200A WIRE AND CONDUIT SIZE JUSTIFICATIONS f?1 T 3P FUSES 3P 3P 3P 3P 3P 3P Uj 3P 3P 3P 3P 3P 3P I A I ! I SPACE DACE I 1 6[(4-500KCMIL+#1/OG)4"C}+2(4"C) 2 2[(3-500KCMIL+#1/OG)3"C]+4(3"C) DATE 12/12/2003 u 1 2 #4/OG TO BUILDING 3 4[(4-250KCMIL+2#2G)3-1/2 C]+ BY CMP d STEEL AND COLD OHg' DISTRIBUTION PANEL 4(3-1/2"C) 480V. 30. 4W, 300DA C WATER PIPES 100.000 AIC 4 3[(4-500KCMIL+#2/0G)3-1/2"C] CHK'D BY CMP L _ = 5ODKCMIL.G TO "MDC" PARTIAL EAST NORMAL 5 (2#1/0+#3G)1-1/2»C SHEET FILE E3,0.OWG >, 1 6 (4#4♦#1/OG)1-1/4 {'i COPYRIGHT 2003 @Y WS PARTNERSHIP P.C.. MCHf MM T MII x ONE-LINE 7 (4#2+#BG)1-1/2"C U NO SCALE > E3mO f cn �O D.P.A. PROJECT# 03942.00 o, ELECTRIQAL SPECIFICATIONS- DIVISION 16000 PART 1 GENERAL 2.05 OWNERSHIP 3.06 DEVICES 1.01 CODES AND REQUIREMENTS A. All equipment, fixtures, devices, etc. which are removed shall be A. Receptacles and switches: configuration shall conform to NEMA presented to the Owner for disposition. All items which are WD-1. Device body shall be ivory plastic unless otherwise noted. A. All electrical work shall comply with the requirements of the removed but not wanted by the Owner and which are not reused latest edition of the National Electrical Code, Local Building become the property of the Contractor and shall be removed B. Mount devices in accordance with the following schedule Code, and as specified herein, whichever is more strict. from the site. except where otherwise noted on the drawings: CONSTRUCTION MANAGER B. The Contractor shall comply with the requirements of the PART 3 PRODUCTS 1,) Convenience receptacles— long axis horizontal 1'-6"AFF The HCBeck Group General Conditions, Supplemental General Conditions, of the 2.) Light switches— latch side of door 4'-0"AFF PO BOX SM project specifications, all Contract Documents, and any base 3.01 EQUIPMENT Avon,Colorado 81620 building specifications and building criteria included in this 3.07 ENCLOSED CIRCUIT BREAKERS project. A. The Contractor shall provide all equipment and accessories necessary, whether specifically stated or not, to make the A. Enclosed molded—case circuit breaker: NEMA AB 1. Circuit C. Visit the premises before submitting bid as no extras will be required electrical systems complete and operational. breakers shall shall bear the UL label and each enclosure shall allowed for lack of knowledge of existing condition& be the NEMA type suitable for the surrounding area and DAVIS PARTNERSHIP ARCHITECTS B. All equipment provided shall be new except as otherwise stated conditions. Circuit breakers shall be thermal—magnetic with 0225 MAIN STREET.UNIT C101 D. Drawings are diagrammatic in nature. Take all dimensions from on the drawings. All equipment provided shall be U.L. listed inverse time—current element for low—level overloads and EDWARDS,COLORADO 81632 Architectural drawings. certified equipment drawings, and from when such standards exist for the type of equipment furnished, instantaneous trip element for short circuits. Circuit breakers 970.926.8960 F.970.926.8961 the structure Itself before fabricating any work, and acceptable for installation by the Local Building Authority. shall have interrupting capacity to meet available fault currents. F. Good workmanship and appearance are considered equal to 3.02 ELECTRICAL IDENTIFICATION B. Switches and circuit breakers shall be as manufactured by Cutler— proper operation. Hammer, General Electric, Siemens, Square D, or as accepted, and A, Provide labeling for receptacle and wall switch coverplates as all switches and circuit breakers provided shall be by the some G. Provide all core drilling, channeling, cutting, patching, as specified on the Drawings. manufacturer, ISSUEIREVISION DATE NO. required for installation of electrical equipment. Seal holes, fireproofing where necessary, and refinish all repair work to B. All junction boxes shall be identified as to circuits contained 3.08 LIGHTING FIXTURES FOR PERMIT 2/12/03 original condition where damaged by electrical work. within, A. Provide all new lighting fixtures complete with lamps, ballasts. H. Make provisions for safe delivery and secure storage of all C. Provide engraved nameplates for all electrical cabinets. enclosures, reflectors, plaster frames, louvers, stem hangars, etc.. and as materials. panelboards. distribution equipment, electrical equipment, boxes, etc. described on the drawings. I. Provide the Architect with a complete set of plans and 3.03 CONDUCTORS 3.09 FUSES specifications corrected to as—built conditions at the completion of the job. A. Minimum size X12 AWG except for control circuits which may A. Fuses shall be as manufactured by Bussmann unless noted be X14 or signal circuits which shill be as indicated. All otherwise on the drawings. 1.02 WARRANTY conductors shall be copper. PART 4 EXECUTION The Contractor shall provide for the Owner a one—year (from the B. Splices for #6 and smaller conductors — Twist—on wire connectors. date of final acceptance) warranty of all electrical equipment and 4.01 CONDUITS/RACEWAYS systems provided under this contract except for incandescent or C. Splices for #4 and larger conductors — Solderless or fluorescent lamps. All defective equipment or materials which compression—type CU/ALR lugs. A. All conductors shall be enclosed by conduit sized in accordance appear during the warranty period shall be replaced or repaired by D. Wiring, type THHN/THWN, unless otherwise noted, with Annex C of the National Electrical Code. Minimum 1/2" the Electrical Contractor In a timely fashion, except for factory furnished lighting fixture flexible conduit may E. Color Coding: Whin for controlsystems to be installed in be 3/8". PART 2 ELECTRICAL DEMOLITION 9� g � conjunction with mechanical and miscellaneous equipment shall 1,) Electrical metallic tubing (EMT) shall be utilized for all 2.01 MATERIALS AND EQUIPMENT be color coded In accordance with the wiring diagrams dry, above grade or above floor applications in accordance p R furnished with the equipment. Branch circuit wiring, including with Article 358 of the National Electrical Code. Couplings Q►:••» �.`��' A. Materials and Equipment for patching and extending work as circuits to motors, and all feeders shall be coded by line or shall be steel compression type, made up wrench—tight. , specified In individual section& phase as fellows: 2.) Flexible metal conduit (FMC) shall be utilized for dl 37276 2.02 EXAMINATION Wire X12 AWG and smaller shall be factory color coded. connections to vibrating equipment such as motors :j7,-x-03: 120/208 Volts 277/480 Volts (minimum 2'-0". maximum 6'-0"), connection to lay—in 669090" A. Verify field measurements and circuiting arrangements as shown Phase A — Black Phase A — Brown type light fixtures, or in remodel areas specifically noted for AL on Drawings. Phase B — Red Phase B — Orange fishing" In existing walls or non—accessible ceilings. Install Phase C — Blue Phase C — Yellow conduit In accordance with Article 348 of the National B. Demolition Drawings are based upon field observation and existing Neutral — White Neutral — Gray Electrical Code. record drawings. Report discrepancies to Architect/ Engineer around -- preen Ground — Green before disturbing existing installation. Switch Swatch B. All exposed conduit (including conduit installed in ceiling plenums shall be routed parallel or Travellers — Pink Travellers -- Purple � P perpendicular to the 2.03 PREPARATION building walls. Support conduit as required by the National L.L Electrical Code. A. Provide temporary wires and connections to maintain existing 3.04 OUTLETS ULI systems In service during construction. When work must C. Provide expansion type fittings for all conduits which cross 00 be performed on energized equipment or circuits, use personnel A. 4" square or octagonal, zinc coated sheet steel boxes. expansion joints. Z J a experienced in such operations. E: B. Provide 3/8" no—bolt fixture studs. 4,02 GROUNDING ��w LO U 2.04 DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK Ll J r C. Provide covers set to come flush with finished walls. A. Distribution equipment, conduit systems. supports. cabinets, J w N 00 A. Extend existing installations using materials and methods equipment, transformers. fixtures, the grounded circuit conductor, ❑ LL Q OCL specified. D. Utility or sectional switch boxes only where permitted. etc. shall be properly grounded In accordance with the latest ❑ 0i m edition of the National Electrical Code. Provide all bonding jumpers r , ❑ 0 B. Where devices, switches, motor connections, etc. are to be 3.05 JUNCTION BOXES AND PULL BOXES and wire, grounding bushings, clamps, etc. as required for complete U cc N removed from walls which are remaining. walls shall be patched grounding. Route ground conductors to provide the shortest and G to match original finish. after conductors hove been removed. A. Locate pull boxes and junction boxes above accessible most direct path to the ground electrode system. Ground � W a Blank coverplates over existing boxes are not acceptable. ceiling or in unfinished areas. connections shall have clean contact surfaces„ tinned and sweated W n/ ❑ 2.05 CLEANING AND REPAIR B. � art while bolting. Install all ground conductors in conduit. pp pull and junction boxes independent of conduit, Q J � � A. Clean and repair existing materials and equipment which remain END OF SECTION W O or are to be reused. W U U J o, A d r J a Q d CD N L —J s O i� ELECTRICAL CS 3 SPECIFICATIONS W 1A 3 A w DATE 12,/12/2003 U DRAWN BY CHIP C5 CHK'D BY CMP SHEET FILE E4.0.DWG d L COPYRIGHT 2003 BY DAMS PARTNERSHIP P.C., ARCHRECTS X U f ■ %D D.P.A. PROJECT# 03942.00