HomeMy WebLinkAboutF10-0009TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Job Address: 168 GORE CREEK DR VAIL Location.....: SUITE 142, LOTUS, LODGE AT VAIL Parcel No...: 210108221008 Project No OWNER YELLOWSTONE CAPITAL LLC 04/21/2010 IN CARE OF NAME SCHAUS & ASSOCIATES LLC 355 S TELLER ST 350 LAKEWOOD CO 80226 APPLICANT WESTERN STATES FIRE PROTECTI 04/21/2010 7026 SOUTH TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S CONTRACTOR WESTERN STATES FIRE PROTECTI 04/21/2010 7026 SOUTH TUCSON WAY ENGLEWOOD CO 80112 License: 338 -S Permit #: F10 -0009 Status ...: ISSUED Applied..: 04/21/2010 Issued . .. 04/26/2010 Expires. .: Phone: 303 - 792 -0022 Phone: 303 - 792 -0022 Desciption: TENANT IMPROVEMENT (LOTUS RESTAURANT): RELOCATE 12 SPRINKLER HEADS, PLUG ONE HEAD. Valuation: $4,600.00 FEE SUMMARY Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $627.50 Plan Check --- > $432.00 DRB Fee ------ — ----------- —> $0.00 Additional Fees------ - - - - -> ($483.50) Investigation -> $0.00 TOTAL FEES -- -------- - -> $627.50 Total Permit Fee ---------- > $144.00 Will Call - - - - -> $0.00 Payments------------------- > $144.00 BALANCE DUE --------- > $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 04/26/2010 sb for David Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. OR CONTRACTOR FOR HIMSELF AND OWNER TOWN OF VAIL, COLORADO Statement ####*****#*###***#********#####*****###********###******#**** * # * * * * * * # * * * * * # * * # # * # # * * * * * * # #* Statement Number: R100000378 Amount: $144.00 04/29/201003:07 PM Payment Method: Check Init: LC Notation: #120142 / WESTERN STATES FIRE PROTECTION ----------------------------------------------------------------------------- Permit No: F10 -0009 Type: SPRINKLER PERMIT Parcel No: 2101 - 082 - 2100 -8 Site Address: 168 GORE CREEK DR VAIL Location: SUITE 142, LOTUS, LODGE AT VAIL Total Fees: $144.00 This Payment: $144.00 Total ALL Pmts: $144.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 SPRINKLER PERMIT FEES 144.00 mnnfi' L J Z > 75' i v'° 01 ^ FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: I 6 i Gore Creej< l bv - • _ (Number) (Street) (Suite #) Building /Complex Name: Contractor Information: Company: W S `= P CompanyAddress: S- TU4S6 , CC, W City: C e_' I 1a ` State: -(--a zip: U / / Contact Name: Job° 4YC���1 Contact Phone: � ^ � E - Mail i eG �� V e1. Ck LQ_ U> S"r p • y� S Town of Vail Contractor Registration No.: 3 3 FS — S X Contra or Signatur (required) Property Information Parcel #: "m O 10 8 a--�_ ) 00 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us/patie) Tenant Name: L0'+u S C l q rle 1/1 o Owner Name: C.p�'1 -� Complete Valuation for Fire Sprinkler Permit: ire Spri� wo -oa Office Use: Project #: Building Permit #: ✓ 77J Sprinkler Permit #: n I O ( ,� ( Lalj� Block #Subdivision: Detailed Description of Work: R6oc -aAt- �,- SaY+ •�k�r- ke-as. � 1 w4 1 Sprt� �l.et- ea (use additional sheet if necessary) Detailed Location of Work: 5tZAc 1 �� Lod of VC:.1 Does a Monitored Fire Alarm Exist? Yes -No ( ) Does a Sprinkler System Exist? Yes-�Q No ( ) Work Class: New ( ) Addition ( ) Remodef�{4 Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commerciai�4 Restaurant ( ) Other ( ) Date Received ApprP s Submitted 10 �4proved as Noted ❑ 3y: roe: _FiQ . LSPOr rn D(o -S�,17 3at+e• oK -aa - 1 `�N b y aB 3 ' D ��9 APR 2 1. 2010 TOWN OF VA, 1 01- Feb -10 S •F �y. X,. � .. si�SN > 75' i v'° 01 ^ FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: I 6 i Gore Creej< l bv - • _ (Number) (Street) (Suite #) Building /Complex Name: Contractor Information: Company: W S `= P CompanyAddress: S- TU4S6 , CC, W City: C e_' I 1a ` State: -(--a zip: U / / Contact Name: Job° 4YC���1 Contact Phone: � ^ � E - Mail i eG �� V e1. Ck LQ_ U> S"r p • y� S Town of Vail Contractor Registration No.: 3 3 FS — S X Contra or Signatur (required) Property Information Parcel #: "m O 10 8 a--�_ ) 00 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us/patie) Tenant Name: L0'+u S C l q rle 1/1 o Owner Name: C.p�'1 -� Complete Valuation for Fire Sprinkler Permit: ire Spri� wo -oa Office Use: Project #: Building Permit #: ✓ 77J Sprinkler Permit #: n I O ( ,� ( Lalj� Block #Subdivision: Detailed Description of Work: R6oc -aAt- �,- SaY+ •�k�r- ke-as. � 1 w4 1 Sprt� �l.et- ea (use additional sheet if necessary) Detailed Location of Work: 5tZAc 1 �� Lod of VC:.1 Does a Monitored Fire Alarm Exist? Yes -No ( ) Does a Sprinkler System Exist? Yes-�Q No ( ) Work Class: New ( ) Addition ( ) Remodef�{4 Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commerciai�4 Restaurant ( ) Other ( ) Date Received ApprP s Submitted 10 �4proved as Noted ❑ 3y: roe: _FiQ . LSPOr rn D(o -S�,17 3at+e• oK -aa - 1 `�N b y aB 3 ' D ��9 APR 2 1. 2010 TOWN OF VA, 1 01- Feb -10 APR 2 12010 D -- r- 6 CEILING ._. _ .... _.. I . I i SI R DRAIN r .0CEILING T.0SOFFIT ` L T4l CEILING A � � 94 EI C LNG 7'E CEILING i � Y � * � * R 7*4 091 NG 94 CEILING Brian Houser Western States Fire Protection Co. NW Level ill B C Registration #121351 rMe: Date: SpriMcbr tem Lay-0 Signature 1. THIS SPRINKLER SYSTEM IS DESIGNED AND INSTALLED PER NFPA 1 2. ALL BRANCH LINES AND ARMOVER PIPING 1 • TYPE M COPPER SPRINKLER PIPING; 3. EXISTING SPRINKLER SYSTEM IS A WET SYSTEM. 4. SYSTEM CHANGES DO NOT AFFECT EXISTING HYDRAULICS. 5. ALL ELECTRICAL, PAINTING, HOLES N CEILING ANDIOR REFLECTED CEILING IS NOT N OUR SCOPE OF WORK, BY OTHERS. B. PROTECTION OF SPRINKLER HEADS IS BY OTHERS. PAINTED OR DAMAGED SPRINKLER HEADS WILL BE REPLACED 7. SPRINKLERS CAN NOT BE CONCEALED BY HARD LID TYPE CEILINGS UNTIL AFTER ROUGKN INSPECTION. 9. HANGERS TO BE LOCATED AND INSTALLED IN ACCORDANCE WITH NFPA -13. 10. KITCHEN IS ORDINARY HAZARD. OWING ROOM IS LIGHT HAZARD. SCOPE OF WORK: RELOCATED EXISTING SPRINKLER HEADS TO NEW TENANT DESIGN RELOCATE -10 PLUG-3 ADD-2 TOTAL OF 12 SPRINKLER HEADS � IC I k �# RELIABLE 06% CONCEALED SPRRIRLER MEAD DRAkNN BY: " PIPESIZE Western States DATE: 4„9NO LOTUS RESTAURANT -LODGE AT VAIL Fke Ptetmfim co. SCALE: t,r•1'A VAIL, CO 81657 174 CFN7'PR r 17 -0 GS, c ow SFItINO3- CO 61601 CONTRACT Ni1BER TENANT FINISH SPRINKLER SYSTEM Td: 303 3409SS] F¢ 97D 4EiA � RNrt N NAIId CdwWa Stsk R%WrjAm N=ba i � l 1 i Ir -7 CEILING i Approved as Submitted CA Approved as Noted 0 K � EXIBTBIGIA LLOICATIDPENDANT BPRIN LER MEADS G ADDED NENII PIHIIao W BPABMM INADB e PLUG EXKTNG BPRBBKLEII HEAD — — — � — EXIBTBIC BPABaCLlR I.EEB COPPER PIPE HANGER @PAC= PIPESIZE MAX WINGER SPACING 1' 9'.0 I-sw 117-0 1 -Ur 117.0 r 17 -0 I- 16 - 000q STATE OF COLORADO DIVISION OF FIRE SAFETY PLAN REGISTRATION FORM Date *­l /D Contractor Registration Number 6 3;L— Contractors Name Mailing Address - 7a d S- Tae -soy, (Jc. v city State eo Zip Code RO / dam Telephone No 303 - ? ?.)-- O& Emergency No. Sae- Name of Project L04LtS S sk. 1 �kr - Project Address 1 (t!�re C vet City ✓� State O Zip Code R/ 6 S Description and Location of Work to be com feted License /Certificate No, or P.E.) (for additional comments use separate sheet) Distribution: Original Copy goes to Division of Fire Safety Upon total completion of form. Copy to local fire department. Copy to contractor and copy to building owner upon completion and sign -off.