ELECTRICAL PERMIT
Electrical Permit Submittal Reauirements Includina Heat Taue Installation
• Floor plan / Site plan showing proposed work
• Building Type
• Occupancy Group listed on plans
❑ Load Calculations and one -line diagram when loads or circuits are being added
NOTE: For Multi - Family and Commercial buildings —plans and calculations must be prepared by a Colorado Licensed Electrical Engineer
Project Street Address: / / 8�?
(Number) (Street) (Suite #)
Building /Complex Name: �/3�ito ✓L C
Contractor Information:
Company: 4_4 T 01— 7`i
Office Use:
Project #:
Building Permit #:
Electrical Permit #:
1F Q Q C)
Lot `- -Block #
t Subdivision:
Company Address: - d k
/ as Define Scope and Location of Work: CA
City: (15.4-/J4 L State: Zip: v` C
Contact Name: FOUp, �C G�.F
Contact P / '71 -
E - Mail L !/C /t L/ /77 TU✓Ld (use additional sheet if necessary)
Town of Vail Contractor Registration No �s� /•-
Includes Temporary Service: ( ) Yes (�N0
X
C r ctor Signature (req red) Work Class:
New ( ) Addition ( ) Remodel (�� Repair ( )
Property Information �/ Other ( ) 1
Parcel #: A ie) l0 O / 0O` � 7 O O
(For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Type of Building:
visit www.eaglecounty.ustp tie) Single- Family ( ) Duplex ( ) Multi - Family ( ) Commercial
Tenant Name: 'e A /,-, i'C /� ( ) Restaurant( ) Other( ) �D
Owner Name: P - A /-e /
Date Received:
Provide BOTH square footage of area of work AND Valuation
(Labor & Materials)
Amount of SQ Ft.:
Electrical $:
z D
p F IE o W [E D
APR 2 2 2010
TOWN OF VAIL
Department of Community Development
75 South Frontage Road
f Vall,�olorado 81657
., Tel: 970 -479 -2128
`
Fax: 970-479-2452
Web: www,vailgov.com
Development Review Coordinator
01- Jan -] 0
Electrical Load Calculation Worksheet
(/ N.E.C. 220.82
THIS SHALL BE ON THE JOB SITE AT ALL TIMES
Permit #
Contractor /Owner:
Job Address: . m. , .o oi� 1 Ae < e1a hG�C' c
Phone # Z ?-! " �/ 2 Z- Z- C 7 Q j
SUBMIT TWO COPIES
Date:
0/ 40
Total Sq. Ft.
Email:
Number
Item
Watts
Air Conditioning Example
(not heat pump)
Compressor 20 amps
Fan 5 amps
Unit Total Load = 25 amps x 240V
Elec. Fumace @ N.P.R.= 6000 watts x 65% _
3900 watts
Use 6000 watts since it is larger
Sq. Ft, @ 3 Watts per Sq. Ft - 220.12
Z
20 Am Appliance circuits was each - 220.52(A)
P� PP @ 1500 wafts )
oba
Range (Nameplate Rating - N.P.R.)
®
i
Overt (N.P.R.)
--- ..... -
Heat Pump Example
Compressor 20 amps
Fan 5 amps
Unit Total Load = 25 amps x 240V =
6000 watts
Aux. Heat Strip = 6000 watts x 65% _
3900 watts
Total Heat Pump Load = 9900 watts
Heat Pump Note:
When doing load calculations where heat
pumps are installed, the load for most heat
pumps that are equipped with auxiliary heat
strips will be larger under the demand for heat.
For purposes of load calculations only, on heat
pump compressor and fans use 65% of
auxiliary heat load to show total heat pump
.--�
Cooking Units (N.P.R.)
Water Heater (N.P.R.)
1
Dishwasher (N.P.R.)
Disposal (N.P.R.)
�p
Washer [(1500 watts min. N.E.C. 220.52(B)]
Dryer [(5000 watts min. or N.P.R. if larger) N.E.C. 220.541
Motors (N.P.R.)
Other (N.P.R.)
Other (N.P.R.)
Air Conditioning Equipment
Air Conditioning [cooling @ (N.P.R. x 100 %)],
Subtotal =
(Loss 1" 10KW - 10,000 @ 100% = 10,000 Watts
Electrical Heating @ (N.P.R. i x 65% =
Remainder @ 40% S 51010 b @ 40 %,. - Watts
NOTE: Use the lariest lodd `- Heat or Cool =
Total Air Cond. and /or heat pump load = Watts
Heat pump (compressor & fans) x 100% =
Total Service Load Watts
Aux. Heat strips' (or elect. furnace) x 65% =
Total Service Load Watts -240V = _Amps
Total Heat Pump Load =
Service Size
NOTE: Amps x Circuit Voltage = Watts
F 2 ? 2: 13
N OF VAIL
Cj0,C)o2S
/3-so -1P
W30 -2010 Inspection Request Re orting Page 53
4:38 pm Vail, CO - City OF
Requested Inspect Date: Thursda�yy Julyy 01, 2010
Assigned To: JMONDRAGON
Insp ection Type: ELEC
Site Address: 595 VAIL VALLEY DR VAIL
UNIT 182
A/P /D Information
Activity: E10 -0025 Type: B -ELEC Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area:
Owner: MAX HAECHLER & ELIZABETH M. HAECHLER
TRUSTEES
Contractor: HEART OF THE ROCKIES ELECTRIC INC Phone: 719 - 942 -5477
Description: WIRING FOR INTERIOR REMODEL
Reauested Inspectionts
Item: 190 ELEC -Final
Requestor: HEART OF THE ROCKIES ELECTRIC INC
Assigned To: ON
Acti Time Exp:
Requested Time: 08:00 AM
Phone: 303 - 886 -1909 (lori)
Entered By: SBELLM K
Inspection Histo
Item: 120 ELEC -Rough "' Approved'"`--- -
05/04/10 Inspector: MDENNEY Action: PA PARTIAL APPROVAL
Comment: CEILINGS.
05/13/10 Inspector: mdenney Action: AP APPROVED
Comment: Panel was not completed at this time, shall be inspected during final.
Item: 190 ELEC -Final
REPT131 Run Id: 11641