,. TOWlV OF VAtI, ' Town of Vail Community Development 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Job Address: 675 LIONSHEAD PL VAIL Location.......: P151, STARBUCKS, ARRABELLE Parcel No.....: 210106326001 OWNER ARRABELLE AT VAIL SQUARE LLC 03/30/2010 PO BOX 7 VAI L CO 81658 Permit #...: E10-0017 Project #..: PRJ10-0095 Issued......: 04/05/2010 APPLICANT NORTHERN LIGHT ELECTRIC, LLC 03/30/2010 Phone: 970-476-5066 PO BOX 643 EDWARDS CO 81632 License: 432-E CONTRACTOR NORTHERN LIGHT ELECTRIC, LLC 03/30/2010 PO BOX 643 EDWARDS CO 81632 License: 432-E Desciption of Work: Valuation: $600.00 Phone: 970-476-5066 INSTALL POWER SUPPLY FOR FOOD OVEN Square feet: **.*****«***«.,******«*,.,«**********„«***«********************«*******«***************.,*.,***,.***.,**********,.****.,*******«««****„«***«***,.**..**,.* CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. *********«****«***««*********«**«****.,********«****************«*.,***********«**,�,.*�,,,,,.,,****x**�****,.,.***„***.,.,,.****„*«******,.*x*******,.**,,*,.** INSPECTIONS If more than two inspections are performed an additional inspection fee will be applied for each inspection requested/needed. All electrical inspections are performed on Tuesdays and Thursdays. Requests must be received the day before and not later than 4 p.m. *************************************«***********************************************************************************************�********.* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. SIGNATURE: Date (Master / homeowner / or non-licensed contractor performing work) PRINTED NAME: elec_permi 100109 ***********************************************r**************************************�**+** TOWN OF VAIL, COLORADOCopy Reprinted on O1-14-2013 at 16:45:04 O1/14/2013 Statement *******+*****************+*++*******************�****++**+************+********************* Statement Number: R100000254 Amount: $193.75 09/05/201011:00 AM Payment Method:Credit Crd Init: LC Notation: CC ROBERT L HOUSER, NORTHERN LIGHT ----------------------------------------------------------------------------- Permit No: Parcel No: 2101-063-2700-8 2101-063-2700-9 2101-063-2701-0 2101-063-2701-1 2101-063-2701-2 2101-063-2701-3 2101-063-2701-4 2101-063-2701-5 2101-063-2701-6 2101-063-2701-7 21.01-063-2701-8 2101-063-2701-9 2101-063-2702-0 2101-063-2702-1 2101-063-2702-2 2101-063-2702-3 2101-063-2702-4 2101-063-2702-5 2101-063-2702-6 2101-063-2702-7 2101-063-2702-8 2101-063-2800-2 2101-063-2800-3 2101-063-2800-4 2101-063-2800-5 2101-063-2800-6 2101-063-2800-7 2101-063-2800-8 2101-063-2800-9 2101-063-2801-0 2101-063-2801-1 2101-063-2801-2 2101-063-2801-3 2101-063-2801-4 2101-063-2801-6 2101-063-2801-7 2101-063-2801-8 2101-063-2801-9 2101-063-2802-1 2101-063-2802-3 2101-063-2802-4 2101-063-2802-5 2101-063-2802-6 2101-063-2802-7 2101-063-2802-8 2101-063-2802-9 2101-063-2803-0 2101-063-2803-1 2101-063-2803-3 2101-063-2803-4 2101-063-2803-6 Site Address: Location: E10-0017 Type: ELECTRICAL PERMIT 2101-063-2600-1 675 LIONSHEAD PL VAIL P151, STARBUCKS, ARRABELLE Total Fees: $193.75 This Payment: $193.75 Total ALL Pmts: $193.75 Balance: $0.00 **************�*****************�*****************+*********�+*************+*************�** ACCOUNT ITEM LIST: Account Code -------------------- 00100003111100, GFPO EP 00100003111100 PF 00100003112300 WC 00100003112800 Description Current Pmts ------------------------------ ------------ ELEC PERMIT FEES-GFP012 85.00 ELECTRICAL PERMIT FEES 30.00 ELEC PLAN REVIEW 74.75 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- E10-0017 : Entries for Item:190 - ELEC-Final 16:45 01/14/2013 Action Comments By Date Unique_ Ke AP sgremmer 04/06/2010 A000132 211 Total Rows: 1 Page 1 RECESSED FLUORESCENT LUMINAIRE, LAY -IN Q RECESS MOUNTED WALL LUMINAIRE ® RECESSED FLUORESCENT LUMINAIRE, FLANGED ZI_V O PORCELAIN KEYLESS LAMPHOLDER, BRYANT #5228 W/ 10OW A19 'PC' TWO POLE SWITCH SV VARIABLE SPEED SWITCH PC I.F. LAMP. INDICATES PULLCHAIN ® SURFACE OR PENDANT MOUNTED LUMINAIRE S I SLj TRACK LIGHTING THERMAL OVERLOAD SWITCH SURFACE OR PENDANT MOUNTED STRIP OR INDUSTRIAL LUMINAIRE 4.P EMERGENCY LIGHTING UNIT a A SHADING INDICATES EM SYSTEM, LOWER CASE SUBSCRIPT INDICATES SWITCHING, UPPER CASE SUBSCRIPT INDICATES LUMINAIRE TYPE TYP MANUAL SWITCH, HORSEPOWER RATED EXIT LIGN7, ARROWS AS INDICATED, FACES INDICATED @Y SHADING COMBINATION SWITCH AND DUPLEX RECEPTACLE SURFACE MOUNTED CEILING LUMINAIRE DIMMER SWITCH 0- 0 POLE MOUNTED LUMINAIRE I EXTERIOR BOLLARD LUMINAIRE ON SITE PLAN �* PUSHBUTTON SECURITY CONTROL PANEL FO SURFACE MOUNTED WALL. LUMINAIRE 11ME CLOCK 0< SPOT LIGHT ® RECESS MOUNTED CEILING LUMINAIRE REFERENCE ® DARKROOM SAFE LIGHT (TWO COMPARTMENT SHOWN) ®3 RECESS MOUNTED CEILING LUMINAIRE - DIRECTIONAL) EXISTING TO REMAIN 15,284 UNDERCOUNTER LIGHTING 23565 EXISTING TO BE REMOVED POWER MECHANICAL EQUIPMENT REFERENCE - SINGLE RECEPTACLE ® MOTOR STARTER EXISTING TO REMAIN - REPLACE DEVICE DUPLEX RECEPTACLE 2.3 KVA I --PM ---- I PLUG -MOLD (MULTI -OULET ASSEMBLY) Gn DUPLEX RECEPTACLE, GROUND FAULT PROTECTION AC I- WM- ---1 WREMOLD (SURFACE RACEWAY) iG DUPLEX RECEPTACLE, ISOLATED GROUND ABOVE FINISHED FLOOR `� CONNECTION TO PREWIRED EQUIPMENT AFG DOUBLE DUPLEX RECEPTACLE MLO MAIN LUGS ONLY FLEXIBLE WIRING CABLE ANNUNCIATOR DUPLEX RECEPTACLE, HALF SWITCHED MANUAL TRANSFER SWITCH ARF CONDUIT, CONCEALED NC DUPLEX RECEPTACLE, CEILING MOUNTED ASSD - - CONDUIT, EXPOSED ® DUPLEX RECEPTACLE, FLOOR MOUNTED AUTOMATIC TRANSFER SWITCH - - - CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR Ep DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED NO -+ CONDUIT TURNING DOWN 4 SPECIAL RECEPTACLE NOT TO SCALE - --Q CONDUIT TURNING UP ® SPECIAL RECEPTACLE, FLOOR MOUNTED CB --- CONDUIT CAPPED Q THERMOSTAT CLOSED CIRCUIT TELEVISION OFOI BRANCH CIRCUIT HOME RUN, NUMBER OF ARROWS INDICATES (E) EXISTING OSWF A -1,3,5 NUMBER OF CIRCUITS, SUBSCRIPT INDICATES PANEL do CIRCUITS �J JUNCTION BOX, WALL OR CEILING MOUNTED PULL BOX T1'U GROUND BAR Q JUNCTION BOX, FLOOR MOUNTED EP EXPLOSION PROOF ELECTRICAL PANELBOARD, CONTROL PANEL OR OTHER SUB - DISTRIBUTION CENTER EPO EMERGENCY POWER OFF TP CABINET, AS NOTED EVO FLEXIBLE WIRING DISTRIBUTION BOX TVSS � MAIN SWITCHBOARD /DISTRIBUTION CENTER ® MOTOR TYPICAL I ' I TRANSFORMER Oj DISCONNECT SWITCH (NON - FUSED) G CT CURRENT TRANSFORMER CABINET UNDER GROUND DISCONNECT SWITCH (FUSED) GENERATOR CONTROL PANEL UON UTILITY METER ZJ COMBINATION STARTER/DISCONNECT UPS GAIN GENERATOR ANNUNCIATOR PANEL HAND OFF AUTOMATIC y SWITCHING IG ISOLATED GROUND , a I SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING) ZI_V LOW VOLTAGE SWITCH S TWO POLE SWITCH SV VARIABLE SPEED SWITCH 5 THREE - WAY SWITCH 4--P EXPLOSION PROOF SWITCH S FOUR - WAY SWITCH S THERMAL OVERLOAD SWITCH DOOR CONTACT KEY OPERATED SWITCH _ C MOMENTARY CONTACT SWITCH CARD READER MANUAL SWITCH, HORSEPOWER RATED ,tp 'jl�S COMBINATION SWITCH AND DUPLEX RECEPTACLE SECURITY CAMERA DIMMER SWITCH DATA OUTLET PHOTOCELL CONTROL I SWITCH WiTH PILOT LIGHT (PILOT LIGHT iS 'ON' WHEN SWITCH IS 'ON') �* PUSHBUTTON SECURITY CONTROL PANEL SWITCH WITH PILOT LIGHT LOCATOR (CONTINUOUSLY LIGHTED HANDLE) FT C 1 11ME CLOCK MAGNETIC DOOR LOCK OTHER 13,962.0 OCCUPANCY SENSOR REFERENCE SYMBOLS 1 DETAIL NOTE REFERENCE A EXISTING TO REMAIN 15,284 KITCHEN EQUIPMENT REFERENCE 23565 EXISTING TO BE REMOVED UH MECHANICAL EQUIPMENT REFERENCE 0 EXISTING TO BE RELOCATED FIRST 10 KVA 2.3 EXISTING TO REMAIN - REPLACE DEVICE ABBREVIATIONS 2.3 KVA A AMPERES MCP MOTOR CIRCUIT PROTECTOR AC ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERUNE OF DEIAM+6" ABOVE COUNTER OR BACK SPLASH MEC SEE MECHANICAL EQUIPMENT SCHEDULE AFF ABOVE FINISHED FLOOR MIN MINIMUM AFG ABOVE FINISHED GRADE MLO MAIN LUGS ONLY ANN ANNUNCIATOR MTS MANUAL TRANSFER SWITCH ARF ABOVE RAISED FLOOR NC NORMALLY CLOSED ASSD AIR SAMPLING SMOKE DETECTION NIC NOT IN CONTRACT ATS AUTOMATIC TRANSFER SWITCH NL NIGHT LIGHT BFG BELOW FINISHED GRADE NO NORMALLY OPEN C CONDUIT NTS NOT TO SCALE CATV CABLE TELEVISION OC ON CENTER CB CIRCUIT BREAKER OFC OWNER FURNISHED, CONTRACTOR INSTALLED CCTV CLOSED CIRCUIT TELEVISION OFOI OWNER FURNISHED, OWNER INSTALLED (E) EXISTING OSWF ON SiTE WORK FORCE EM EMERGENCY PB PULL BOX EMDC EMERGENCY MAIN DISTRIBUTION CENTER SB STAND -BY EP EXPLOSION PROOF SDC SUB - DISTRIBUTION CENTER EPO EMERGENCY POWER OFF TP TAMPER PROOF EVO EMERGENCY VENTILATION ON /OFF TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER EWC ELECTRIC WATER COOLER TYP TYPICAL FA FIRE ALARM OF UNDER FLOOR G GROUND UG UNDER GROUND GCP GENERATOR CONTROL PANEL UON UNLESS OTHERWISE NOTED GFI GROUND FAULT INTERRUPTING UPS UNINTERRUPTABLE POWER SUPPLY HOA HAND OFF AUTOMATIC y VOLTS IG ISOLATED GROUND VFD VARIABLE FREQUENCY DRIVE MAX MAXIMUM W/ WITH MCB MAIN CIRCUIT BREAKER W/O WITHOUT MCC MOTOR CONTROL CENTER WP WEATHER PROOF MDC MAIN DISTRIBUTION CENTER XF-MR TRANSFORMER 1 A GENERAL SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. SITE EXAMINATION THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED iN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS /SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO LICENSEE. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY LICENSEE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. COORDINATION THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. TESTING ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. TEMPORARY POWER THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL WIRING FOR CONSTRUCTION. THE TEMPORARY SERVICE SHALL BE A MINIMUM OF 60 AMPS, SINGLE PHASE, THREE WIRE, 120/208 VOLTS FUSED AT MAIN DISCONNECT. ALL RECEPTACLES ON THIS TEMPORARY SERVICE SHALL BE PROTECTED BY A GFI BREAKER. MECHANICAL EQUIPMENT ALL FINAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. EXISTING SYSTEMS DEMOU11ON THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. POWER OUTAGES THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:00PM AND 5:OOAM. BASIC MATERIALS AND METHODS MATERIALS PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED AND LABELED, OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE LOCAL JURISDICTION, FOR THE PURPOSE FOR WHICH THEY ARE USED, iN ADDITION TO MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS, NO SUBSTITUTION TO MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. CUTTING AND FITTING PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT OF THIS SECTION. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE LICENSEE AND LANDLORD. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES, AND HOLES IN SLABS, WALLS, AND CASEWORK. RACEWAYS PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT AND COPPER CONDUCTORS, OR MC CABLE FOR MECHANICAL EQUIPMENT, LIGHTING, AND POWER. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORROSION- RESISTANT FITTINGS. SCHEDULE 40 PVC IS ACCEPTABLE WHERE PERMITTED BY CODE AND FOR UNDERGROUND RUNS OR CONCRETE ENCASEMENT WHERE NOT EXPOSED TO PHYSICAL DAMAGE. THE MINIMUM SIZE OF CONDUIT SHALL BE 1/2" UNLESS OTHERWISE NOTED. CONDUIT RUNS CONCEALED IN CONCRETE SHALL BE 314" MINIMUM, UNLESS OTHERWISE NOTED. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. RIGID CONDUIT SHALL BE HOT DIPPED GALVANIZED. BRANCH CIRCUIT WORK CHASED INTO EXISTING CONSTRUCT10N FOR CONCEALMENT UNDER PATCHED FINISHES SHALL BE INSTALLED IN RIGID CONDUIT, OR EMT, WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRING. PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FiRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T &B FLAMESAFE OR OTHER APPROVED METHOD. CONDUCTORS AND TERMINATIONS CONDUCTORS AND TERMINTATIONS CONDUCTORS SHALL BE COPPER, INSULATED FOR 60OV. TYPE THWN/THHN. NUMBER 12 AWG MINIMUM. MOTORS AND OTHER WIRING THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED CONDUIT, WIRING, AND SAFETY SWITCHES FOR ALL MOTORS, AND OTHER ELECTRICAL EQUIPMENT , EVEN THOUGH THE MOTORS AND ELECTRICAL EQUIPMENT MAY BE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. SHALL BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS REQUIRED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. THE ELECTRICAL EQUIPMENT MAY INCLUDE BUT NOT BE LIMITED TO SUCH ITEMS AS GRILLE MOTORS AND INTERLOCKS, STOREFRONT AND INTERIOR SIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES, ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATA SYSTEMS, INTERCOMS AND STEREO SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCA11ON AND SIZES WITH THE TRADE SUPPLYING THE EQUIPMENT BEFORE INSTALLING THE CONDUIT OR OUTLETS. SWITCHES AND RECEPTACLES SWITCHES SLATER NO. 2770 -WH OR APPROVED EQUAL WITH MATCHING COVERPLATES. INCANDESCENT DIMMERS LUTRON NOVA T SERIES WITH MATCHING COVERPLATES, 1500 WATT MAXIMUM, AS REQUIRED FOR FIXTURE QUANTITIES SHOWN ON THE LIGHTING PLAN. RECEPTACLES LUTRON NOVA T SERIES WITH MATCHING COVERPLATES, 1500 WATT MAXIMUM, AS REQUIRED FOR FIXTURE QUANTITIES SHOWN ON THE LIGHTING PLAN. SLATER NO. 6242SM OR APPROVED EQUAL WITH MATCHING COVERPLATES. INSTALL RECEPTACLES WiTH GROUND PIN UP AT +15" UNLESS OTHERWISE NOTED. AT BACKBAR MOUNT AT +10" ABOVE COUNTERTOP UNLESS OTHERWISE NOTED. PROVIDE GFCI TYPE WHERE INDICATED. OCCUPANCY SENSORS WATTSTOPPER #WA -100 -WHITE FOR USE IN ALL TOILET ROOMS. DISCONNECTS AND FUSED SWITCHES FUSED SWITCHES HEAVY DUTY TYPE, HORSEPOWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL. OUTDOOR AND WET LOCATION SWITCHES SHALL BE RAINTiGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600 AMPERES OR LESS SHALL BE UL CLASS RK1 DUAL - ELEMENT, TiME- DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601 AMPERES OR LARGER SHALL BE UL CLASS L TiME- DELAY, CURRENT LIMITING FUSES. NAMEPLATES PROVIDE PERMANENT NAMEPLATE LABELING ON ALL DISCONNECTS. INCLUDE LOAD SERVED, VOLTAGE, PHASE, HORSEPOWER, FUSE SIZE, AND TYPE. MOUNTING MOUNT INDEPENDENT OF THE MECHANICAL UNIT HOUSING UNLESS SPECIFICALLY ACCEPTED BY THE LOCAL CODE AUTHORITY. PROVIDE UNISTRUT SUPPORT CHANNELS MOUNTED IN COORDINATION WITH ROOF PENETRATION AND PATCHING WORK. COORDINATE WITH GENERAL CONTRACTOR. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS AS PROVIDING GROUND CONTINUITY. PANELBOARDS PROVIDE BRANCH CIRCUIT PANELBOARD(S) AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. PANELBOARDS SHALL HAVE PLUG -IN BREAKERS AND MAIN LUGS ONLY OR MAiN BREAKERS AS REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 TYPE HOUSING AS MANUFACTURE BY "SQUARE D ", "ITE% OR EQUAL. ENCLOSURE(S) SHALL BE COMPLETE WITH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED DIRECTORY UNDER PLASTIC COVER IN EACH PANEL DOOR. ALL MULTIPLE POLE BREAKERS SHALL HAVE A COMMON TRIP HANDLE. LIGHTING PROVIDE A NEW LIGHTING SYSTEM COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE AND UL LiSTiNG REQUIREMENTS. CLEAN ALL FIXTURES AT TIME OF JOB COMPLETION UTILIZING MANUFACTURERS APPROVED OR RECOMMENDED CLEANING SOLUTIONS. ALL FIXTURES AND LAMPS ARE SELECTED AND PROVIDED BY STARBUCKS AS SCHEDULED ON SHEET SC.2 UNLESS NOTED OTHERWISE. TELEPHONE SYSTEM TELEPHONE WIRING AND SYSTEM PROVIDED BY LICENSEE. VERIFY SYSTEM REQUIREMENTS AND ROUGH -IN LOCATIONS WITH LICENSEE PRIOR TO START OF CONSTRUCTION. SECURITY SYSTEM NOTES SECURITY WIRING AND SYSTEM PROVIDED BY LICENSEE. VERIFY SYSTEM REQUIREMENTS AND ROUGH -IN LOCATIONS WITH LICENSEE PRIOR TO START OF CONSTRUCTION. POS / DATA LINE NOTES P.O.S. WIRING AND SYSTEM PROVIDED BY LICENSEE. VERIFY SYSTEM REQUIREMENTS AND ROUGH -IN LOCATIONS WITH LICENSEE PRIOR TO START OF CONSTRUCTION. SYSTEMS LEGEND (Not all symbols listed below are used on these drawings) SYMBOL DESCRIPTION SYMBOL DESCRIPTION © TELEPHONE TERMINAL CABINET (SIM PAGING SYSTEi,I SPEAKER 'M' INDICATES MUSIC SYSTEM ONLY BREAKER TELEPHONE TERMINAL BACKBOARD <� VOLUME CONTROL GENERAL TELEPHONE OUTLET W --WALL, P =PAY T DOOR CONTACT ® TELEPHONE OUTLET, FLOOR MOUNTED F CARD READER A TP TELEPHONE/POWER POLE E= SECURITY CAMERA 2,080 DATA OUTLET ES ELECTRIC DOOR STRIKE �► COMBINATION TELEPHONE/OATA OUTLET FSCP1 SECURITY CONTROL PANEL 0 TELEVISION OUTLET ML MAGNETIC DOOR LOCK Cotor, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- LEC.DWG - E1.0 PLOT: 02/25/2010 0 2:10pm REV. 02/25/2010 CAD: )ITafer XREF: tb.dwg EXISTING PANEL "NE5" Panel Notes: 250 A MAIN CIRCUIT BREAKER VOLTAGE 277 1480 V 1. NEW CiRCUiT BREAKER IN EXISTING PANELBOARD 400A BUS PHASE 3 PH WIRE 4 W TYPE: CUTLER MTG.: SURFACE' 14,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL BREAKER CCT PH CCT BREAKER TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCR NOTE AMP J P AMP / P I PANEL "NE5L" 1,200 2,080 5,922 13,962 0 23164 175/ 1 A 2 20/ 1 0 x 95% = 2.9 KW 97% OTHER 13,962.0 S 14,180.0 1720 RECEPTACLES 1,250 0 7,031 15,284 0 23565 / 3 B 4 20 / 1 0 7,759.6 FIRST 10 KVA 2.3 KVA SPARE 2.3 KVA x 100% = 2.3 KW 0 180 7,098 14,180 0 21458 / 3 5 C 6 20/ 1 0 0.0 KVA x 100% = 0.0 KW AMPACITY = SPARE " WH -1 MOTORS 1,362 7,760 7760 45/ 7 A 8 20 / 1 0 6 20/ 1 LARGEST 21.3 SPARE x 125% = 26.6 KVA x 90% = 24.0 KW E004,E533 PHASE AMPACITY 130.5 7,760 7760 / 9 B 10 201 1 0 x 100% = 1.2 KVA x 90% = 1.1 KW NEC DEMAND SPARE 201 1 8401 " OTHER 43.4 KVA 7,760 7760 / 3 11 C 12 20/ 1 0 250.0 GENERAL SPARE KVA x 100 % = SPARE x 100% = 23.3 KW 101.9 PHASE BALANCE A -B 0 20/ 1 13 A 14 20/ 1 0 FCU -1 SPARE 1% SPARE 6%1 11 TOTAL 94.0 KVA 0 201 1 15 B 16 20 / 1 4 GENERAL NOTES: SPARE E451 SPARE 4,560 BREAKER ACCESSORIES 'PROVIDE NEW UPDATED 0 20/ 1 17 C 18 20/ 1 0 600 * = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES iN PENCIL. SPARE E338 SPARE *" = SHUNT TRIP 4,560 0 20/ 1 19 A 20 20 / 1 0 B 16 2011 456 SPARE 456 SPARE A300 0 20/ 1 21 B 22 201 1 0 45601 3 17 C SPARE 501 SPARE 3,858 0 20/ 1 23 C 24 201 1 0 1,020 SPARE 20/ 1 19 SPARE 20 / 2 3858 0 20/ 1 25 A 26 2O 1 1 0 E422 SPARE 1,200 SPARE 120 20/ 1 21 B 22 0 2011 27 B 28 2011 0 3,858 E162 SPARE E431 SPARE 1,020 102 0 20/ 1 29 C 30 20/ 1 0 / 2 3858 3,858 SPARE SPARE E206,207,208 0 20/ 1 31 A 32 201 1 0 25 A 26 20 / 1 SPARE SPARE E301 0 241 1 33 B 34 20 t 1 0 1,560 156 20 / 1 27 SPARE 28 SPARE 136 1,368 0 20/ 1 35 C 36 201 1 0 1. 1,560 SPARE 201 1 SPARE C 30 20t 1 180 0 20/ 1 37 A 38 20/ 1 0 GENERAL RCPT SPARE SPARE 20/ 1 31 A 01 20/ 1 1 39 B 40 201 1 0 200 SPARE 1 SPARE 1,560 :E840 0 20 / 1 41 C 42 20 / 1 0 20/ 1 575 SPARE 575 PHASE LOADING SUMMARY PANEL LOADING SUMMARY LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND LIGHTING 1,200.0 1,250.0 0.0 M LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL RECEPTACLES 2,080.0 0.0 180.0 MOTORS OTHER GENERAL TOTAL BREAKER CCT PH CCT CONNECTED PF= MOTORS 5,922.0 7,031.0 7,098.0 RECEPT LIGHTING 2.5 KVA x 125% =' 3.1 KVA x 95% = 2.9 KW 97% OTHER 13,962.0 15,284.0 14,180.0 1720 RECEPTACLES 1 A 2 50/ 3744 GENERAL 7,759.6 7,759.6 7,759.6 FIRST 10 KVA 2.3 KVA x 100 % = 2.3 KVA x 100% = 2.3 KW CONNECTED TOTAL (VA) 30,923.6 31,324.6 29,217.6 B REMAINDER 0.0 KVA x 50 %= 0.0 KVA x 100% = 0.0 KW AMPACITY = " MOTORS 1,362 136 1110 NEC CALCULATED C 6 20/ 1 LARGEST 21.3 KVA x 125% = 26.6 KVA x 90% = 24.0 KW E004,E533 PHASE AMPACITY 130.5 134.1 124.5 REMAINDER 1.2 KVA x 100% = 1.2 KVA x 90% = 1.1 KW NEC DEMAND 201 1 8401 OTHER 43.4 KVA x 65 %= 28.2 KVA x 100% = 28.2 KW AMPACITY = 250.0 GENERAL 23.3 KVA x 100 % = 23.3 KVA x 100% = 23.3 KW 101.9 PHASE BALANCE A -B B -C C -A E338 FCU -1 1,176 1% 7% 6%1 11 TOTAL 94.0 KVA / 2 8 4.7 KVA 81.7 KW 1,508 GENERAL NOTES: E451 4,560 BREAKER ACCESSORIES 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. 14 20/ 1 600 * = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES iN PENCIL. E338 *" = SHUNT TRIP NEW PANEL "NE5L " Panel Notes: 400 A MAiN CIRCUIT BREAKER VOLTAGE 120 1208 V I. CIRCUIT VIA ASTRONOMICAL TIME CLOCK CONTACT. 400 A TYPE: SQUARE D MTG.: SURFACE BUS PHASE 3 PH WIRE 4 W 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) M d 4 0 0 n X o NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL BREAKER CCT PH CCT BREAKER TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE AMP / P AMP / P GENERAL RCPT 1,720 1720 201 1 1 A 2 50/ 3744 3,744 El 52 SOUND SYSTEM 30 30 20/ 1 3 B 4 / 2 3744 3,744 " E314 1,362 136 20/ 5 C 6 20/ 1 153 1,536 E004,E533 " 1,362 1362 2 7 A 8 201 1 8401 840 E334 SPARE 0 20/ 1 9 B 10 20/ 1508 1,508 E338 FCU -1 1,176 117 20/ 1 11 C 12 / 2 150 1,508 E451 4,560 4560 50/ 13 A 14 20/ 1 600 600 E338 4,560 4560 ! 15 B 16 2011 456 456 A300 4,560 45601 3 17 C 18 501 3858 3,858 E162 E420 1,020 102 20/ 1 19 A 20 / 2 3858 3,85 E422 1,200 120 20/ 1 21 B 22 501 3858 3,858 E162 E431 1,020 102 201 1 23 C 24 / 2 3858 3,858 E206,207,208 1,500 150 .." 20/ 1 25 A 26 20 / 1 840 840 E301 E532 1,560 156 20 / 1 27 B 28 201 1 136 1,368 E574 1. 1,560 201 1 29 C 30 20t 1 180 180 GENERAL RCPT 1,560 20/ 1 31 A 32 20/ 1 200 200 EXTERIOR SIGNAGE 1 1,560 :E840 201 1 33 B 34 20/ 1 575 575 CUH -I E334 840 20 / 1 35 C 36 20 / 1 0 __+ LIGHTING 1 37 A 38 20 / 1 100q 1,000 LIGHTING 1 WARMER 1,750 1750 39 B 40 20/ 1 24261 1,176 1,250 OH COILING DOOR 1,7501 1750 2 41 C 42 20/ 1 01 SPARE OADING SUMMARY LOAD TYPE (VA) LIGHTING RECEPTACLES MOTORS OTHER GENERAL PH A 1,200.0 2,080.0 5,922.0 13,962.0 OA PH B 1,250.0 0.0 6,311.0 15,284.0 1,750.0 PH C 0.0 180.0 7,098.0 14,180.0 1,750.0 LOAD TYPE LIGHTING RECEPTACLES MOTORS OTHER GENERAL _ CONNECTED LOAD KVA 2.5 KVA FIRST 10 KVA 2.3 KVA REMAINDER 0.0 KVA LARGEST 13.7 KVA REMAINDER 5.7 KVA 43.4 KVA 3.5 KVA TOTAL 71.0 KVA NEC CALCULATED DEMAND x 125% = x 100 % = x 50% = x 125% = x 100% = x 65 %= x 100%= LOAD 3.1 KVA 2.3 KVA 0.0 KVA 17.1 KVA 5.7 KVA 28.2 KVA 3.5 KVA 59.8 KVA POWER FACTOR x 95% = x 100% = X100% = X90% = x 90% = x 100% = x 100% = DEMAND LOAD KW 2.9 KW 2.3 KW 0.0 KW 15.4 KW 5.1 KW 28.2 KW 15 KW 57.4 KW PANEL CONNECTED PF= 96% CONNECTED AMPACITY 197,0 NEC DEMAND AMPACITY = 166.0 TOTAL (VA) 23,164.0 24,595.0 23,208.0 NEC CALCULATED PHASE AMPACITY 233.7 248.4 232.0 400.0 PHASE BALANCE A -B B -C C -A 6% 6% RO GENERAL NOTES: 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THiS PROJECT, ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. BREAKER ACCESSORIES * = GFCI ** = SHUNT TRIP MECHANICAL EQUIPMENT SCHEDULE KEY ITEM MOTORS OTHER EQUIV. VOLTAGE FEEDER PROTECTION DISC AT UNIT NOTE HP FLA WATTS LD (VA) VLTS PH SETS SIZE "C BREAKER JDISC SW. ____j FUSE DiSC. SW. FUSE FCU -1 EXISTING FAN COIL UNIT 112 1,176 120 1 1 2 # 12 1 # 12 G 314 20 A 1 P 30 A 1 P 12 1 CUH -1 CABINET UNIT HEATER 1 1/4 1 1 696 120 [1 11 2 12 t # 12 G 3/4 20 A 1 P 30 A I P WH -I WATER HEATER 1 1 8.0 1 23,2791 480 1 3 1 1 3# 6 1# 10 G 1 45 A 3 P 60 A 3 P NOTES: 1. EXISTING FAN COIL UNIT. TENANT TO PROVIDE BRANCH CIRCUITING TO UNIT AND 120V THERMOSTAT. iown of Va OFF I= , UO dx �1 ti �1 �+4 i • i • 1 C.AToj RtliNIA EA ssoaAns Co CONSULTING P i'- CFIANICAVIELECTRICAL FNCID;EERS @'Jb Tator Strcct. Lakco -oc, 00 8W1-t00 3031232•6200 Pax 303!.333701 croUcatorrama.corn wwwcatornjrra.com ASI #1 _ 09/24/0 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. Z M d 4 0 0 n X o o d = o z U = w z n w z C.AToj RtliNIA EA ssoaAns Co CONSULTING P i'- CFIANICAVIELECTRICAL FNCID;EERS @'Jb Tator Strcct. Lakco -oc, 00 8W1-t00 3031232•6200 Pax 303!.333701 croUcatorrama.corn wwwcatornjrra.com ASI #1 _ 09/24/0 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. NE5L -32 SEE DETAIL ll /A7.0 FOR LOCATIONS OF LANjPOS/EIfCTRICAL DEVICES AND EQUIPMENT AT BEVERAGE P.O.SS VERIFY WITH LICENSEE PRIOR TO CONSTRUCTION. NEMA 5-20R RECEPTACLE 0 54" AFF FOR MUSIC SYSTEM. <;, > EXISTING FAN COIL UNIT. CONTRACTOR TO CIRCUIT TO NEW PANELBOARD NEMA 5-20R RECEPTACLE 016" AFF IN STORAGE CABINET. SEE DETAIL 6/A7.0. <1,7> GFI RECEPTACLES 0 48" & 18" AFF, SEE DETAIL 1/A7.1. PROVIDE 2 "C WITH PULLCORD FROM TELECOM ROOM TR -1D, THIS FLOOR, APPROXIMATELY 80' -0" FOR TELECOM CABLING. COORDINATE CABLING REQUIREMENTS WITH OWNER. D EN O TED GENERAL NOTES: 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS. NO EXPOSED CONDUIT WILL BE ALLOWED IN THE PUBLIC VIEW. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN AND ORDERING MATERIALS OR EQUIPMENT. 7. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 8. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND /OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA do ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 9. DIMENSIONS INDICATED ARE TO THE FINISH FACE UNLESS OTHERWISE NOTED. 10. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. ALL BRANCH CIRCUITS ARE 2f12, #12G, 1/2 "C UNLESS OTHERWISE NOTED. POWER PLAN NOTES: I. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT. 2. PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS, 3. DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE. DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE AND MOUNTED AT 6' -3 ", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS. 4. RECEPTACLES INDICATED TO BE MOUNTED ABOVE COUNTER ARE TO BE MOUNTED HORIZONTALLY 6" ABOVE COUNTER. 5. PROVIDE 4" SQUARE OUTLET BOX, SINGLE GANG MUD RING AND BLANK SINGLE GANG COVER PLATE FOR ALL INDIVIDUAL TELEPHONE, DATA, COMBINATION TELE /DATA AND TELEVISION OUTLETS. ROUTE 3/4" CONDUIT WITH PULL WARE TO 6" ABOVE ACCESSIBLE CEILING. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. 6 • COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH -IN. REFER TO CASEWORK DETAILS ON SHEETS A7.0 - A7.2. 7. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. 8. ALL RECEPTACLES IN KITCHEN AREA AND AT PREP COUNTERS SHALL BE GFl PER NEC 210.8.B.(2). 9. NO RECEPTACLES SHALL BE MOUNTED BELOW +18" AFF UNLESS OTHERWISE NOTED. 10. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. 11, JUNCTION BOXES, CONDUIT, AND OUTLETS MOUNTED INSIDE CASEWORK SHALL BE POSITIONED TO AVOID OBSTRUCTIONS OF EQUIPMENT SUCH AS REFRIGERATION AND DISHWASHER, AND POSITIONED TO ALLOW MAXIMUM AMOUNT OF STORAGE CAPACITY IN CABINETS. 1 r•i i ii i 4 EO till, C ATOR,1 uNIA � ASSomTES, Co. C.ON XUT C, ,MF(.'HANICALELECTRICAI. F.. *aTNF.ERS 899 Tabor Street. Lskc - mvcod,CO W01.470 303r,32 .6200. Fax?03PL33�3;:' mocatarnrma.cam . roxx ^.catarn�ma.corn ASI #1 _ 09/24/07 PERMIT �. 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALT. REMAIN PROPERTY OF THE ARCHITECT, AND NO PART" THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS, CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. r • i r KEY NOTES: 11 NOT USED. NEMA 5-20R RECEPTACLES FOR RETAIL GRINDER. SEE DETAIL 5/A7.1 �- NEMA 14-50R RECEPTACLE FOR TWIN BREWER, 3/4 "C - 3#6 AND 1 #10G. SEE DETAIL 3/A7.1, CONTRACTOR TO PROVIDE A NEMA 6 -50P ��.� CORD CAP FOR THE BREWER, BRYANT OR EQUAL. NEMA 6-508 3/4 E � OCL SEE DETAIL MACHINE, A 5 A HOT SEE DETAILS UNDERCOU ER TOR d RIGE AND • az•�r . <> NEMA 5-20R RECEPTACLE FOR ICE MACHINE. » HARDWARE EQUIPMENT CONNECTION AT FOOD CASE. PROVIDE SEPARATE (1 12OV, 15 AMP, AND (1 220 V 20 AMP DEDICATED CIRCUITS. ROUTE CONDUIT TO SIDE OF CASE 0 9' AFF FROM ADJACENT BEVERAGE POS CABINET STUB -UPS. NEMA 14-50R RECEPTACLE FOR DISHWASHER, 3/4 "C - 3#6 AND 1#10G. NEMA 5-20R RECEPTACLE 0 15" AFF. N p V v � Z O O M o X a w O < o - V _ o C ATOR,1 uNIA � ASSomTES, Co. C.ON XUT C, ,MF(.'HANICALELECTRICAI. F.. *aTNF.ERS 899 Tabor Street. Lskc - mvcod,CO W01.470 303r,32 .6200. Fax?03PL33�3;:' mocatarnrma.cam . roxx ^.catarn�ma.corn ASI #1 _ 09/24/07 PERMIT �. 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALT. REMAIN PROPERTY OF THE ARCHITECT, AND NO PART" THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS, CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. r • i r KEY NOTES: 11 NOT USED. NEMA 5-20R RECEPTACLES FOR RETAIL GRINDER. SEE DETAIL 5/A7.1 �- NEMA 14-50R RECEPTACLE FOR TWIN BREWER, 3/4 "C - 3#6 AND 1 #10G. SEE DETAIL 3/A7.1, CONTRACTOR TO PROVIDE A NEMA 6 -50P ��.� CORD CAP FOR THE BREWER, BRYANT OR EQUAL. NEMA 6-508 3/4 E � OCL SEE DETAIL MACHINE, A 5 A HOT SEE DETAILS UNDERCOU ER TOR d RIGE AND • az•�r . <> NEMA 5-20R RECEPTACLE FOR ICE MACHINE. » HARDWARE EQUIPMENT CONNECTION AT FOOD CASE. PROVIDE SEPARATE (1 12OV, 15 AMP, AND (1 220 V 20 AMP DEDICATED CIRCUITS. ROUTE CONDUIT TO SIDE OF CASE 0 9' AFF FROM ADJACENT BEVERAGE POS CABINET STUB -UPS. NEMA 14-50R RECEPTACLE FOR DISHWASHER, 3/4 "C - 3#6 AND 1#10G. NEMA 5-20R RECEPTACLE 0 15" AFF. 1 <'��`> NEMA 5 -20R RECEPTACLE FOR "C" WATER FILTER SYSTEM 0 67" A.F.F. NEMA 5 -20R RECEPTACLE FOR COFFEE WARMERS. SEE DETAIL 3/A7.1. E "> (2) NEMA 5-208 RECEPTACLES FOR BLENDERS IN 4-PLEX BOX, MOUNT BOX TO DE -WALL ABOVE BLENDER CABINET, EACH DUPLEX RECEPTACLE TO BE SEPARATED TO RECEIVE TOTAL SEE DETAIL 1/A7(l 2) DEDICATED CIRCUI1S, (4) DEDICATED CIRCUITS NEMA 5-208 RECEPTACLE FOR SCALE. SEE DETAIL 5/A7.1. <9> I NEMA 6 -30R RECEPTACLE FOR WARMER. NOT USED. CONTRACTOR TO PROVIDE DIRECT ACCESSIBLE POWER FOR ALL ELECTRICAL SIGNAGE WITHIN 6 " -O' OF SIGNAGE LOCATION. CONTRACTOR TO PROVIDE TWO (2) SPARE 3/4" CONDUITS WITH PULL STRINGS FROM ELECTRICAL PANEL TO BARRISTA, AND SHALL BE STUBBED AND CAPPED 6" AFF INSIDE CASEWORK. 'gA' CONTRACTOR / PROVIDE A Na +' C CAP FO a• ` 1 MA CHINE O FOR CTS2 ESPRESSO MACHINES, CIRCUIT VOLTAGE SHALL BE BETW EEN r AND 225 VOLTS REQUIRED THE CONTRACTO SHALL INSTALL A STM3UCKS PROVIDED 1.5 kVA BUCK-BOOST TRAN SFO I IMER TO BE MOUNTED TO THE INS O BARISTA. CONTACT STARBUCKS DM PRIOR 70 EQUIPMENT INSTALL IF A BU C K — BOOST IS REQ < �>II . i 40* NOT USED. Cotor, Ruma €c Assoc. FILENAME:P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- PWRI.DWG - E2.0 PLOT: 02/25/2010 0 2:09pm REV: 02/25/2010 CAD: jhafer XREF: bgl.dwg xbgl- xfloorplan.dwg xbgl- eq- furn.dwg pwrl.dwg tb.dwg hvl.dwg I I I l TEM#, QTY j DESCRIPTION I MANUFACTURER I M0DEL r'F` VOLTS WATTS E AMPS REMARKS i SKU RESP. PEN DAN'?S /SCONCES I ELATE C4V 113T 1 26 J LAMP FOR PEND 17W L011 ! 1 IBSTORE HNDOFF I BAST.... SOURCE SC{TEC ?93 120/208 120 � ; STORE - BROMA - � 1 =1844 a 1 � SB � 1- f YELLOW 1 1893113 L" i9 14 8 IN LAMP FOR ' 120 1 32 22 rFLUORESCENT BULB L926 L AhAP 29392 ( 120 30� i j NETWORK CF30EL /TWISTf1 /8L SB 140005 MONORAIL TRACK E208 1 70CII10A i SBUX4840 115 j 3.8 ; COME IN 8' LENGTHS, ADL4 °RACK & TRACK FIXTURES TECH LIGHTING III I VARIES CLEAR TRACK FIXTURE } Ll 45 1 8 ( JUNO `t+t R552WH I I USES L9 47 LAMP 1 1659: SB L174- f 1 TRACK WHITE 8' � JUNO R9WH � � � 105939 I SB NE5L �- FLUORESCENT FIXTURES 12GT 332 Al2 L563 1 3 2X4 FOR AC' LI THONIA 1120GEB 120 { � W/ (3) L966 LAMPS j 119695 SB Ann Tinr ITFVA, '" VERTICAL CFL ADL.1 1 22 4 I ELATE C4V 113T 1 26 J LAMP FOR PEND 17W TECHNICAL CONSUMER PRODUCT I I SB , DO WNLIGHT SC{TEC SCi t EC 205T ; I 120/208 W/ HOLD BUTTON 160 PAR 30 LAMP 160 PAR SB LIGHTS IN FOOD PREP COMPACT � 1- 3/8 CWF 1 1893113 L" i9 14 8 IN LAMP FOR ' 120 1 32 22 rFLUORESCENT BULB 2X4 OR STRIP 29392 ( 120 30� i Ann Tinr ITFVA, '" VERTICAL CFL ADL.1 1 22 4 I ELATE C4V 113T 1 26 VOLTS I I I SB , DO WNLIGHT SC{TEC SCi t EC 205T ; I 120/208 W/ HOLD BUTTON 178081 LC 4AMPS 0 240V 105373 I SB € COMPACT � I 37.7 3/8 CWF 1 1893113 PLAYER 5 PER CASE/ ORDER: { 0400 � A D_2 22 rFLUORESCENT BULB SLYVANlA 29392 ( 120 30� i j NETWORK CF30EL /TWISTf1 /8L SB 140005 MONORAIL TRACK E208 1 70CII10A i SBUX4840 115 j 3.8 ; COME IN 8' LENGTHS, ADL4 5 j SYSTEM TECH LIGHTING III I VARIES CLEAR J " CURVE ON SITE. C, C 1 700 MO JOHN I I ��- ADL5 8 TILT HEAD - JOHN TECH LIGHTING is GC SUSPENDED I 16 ADL8 5 MONOPOINT TECH LIGHTING 700JSCO67C LAMP GO I WALL. M1TD ARCH LGNIRC -W- LED GC XEM 1 EM BATTERY UNIT LIGHT0L2ER SC72TA I PROVIDE STEM KIT CEILING MTD EPA X10 1 LITHCNIA AFN- W -PREM XENON IF NEEDED � BATTERY EXIT Y i Y II< I ITEM## QTY I DE.SCRlPTION MANUFACTURER MODEL � � VOLTS � AMPS SUPPLY WASTE � REMARKS SKU ## j RESP. At ;Xli IrlpY CYC'i "one �. ACCESSORIES AMERICAN I ( I I A602 4 , POS BANK W /225X PIN SECURITIES i i 155279 LC ADDITIONAL ITEMS i J I WWW.TANNOY.COM / I ADL3 3 MUSIC SPEAKERS TAN! 4OY CF1S501 BM € I 1 .519.475.11 58 ! GC (TEM# QTY I PHONE - 1 LINE MANUFACTURER 4 MODEL �'# VOLTS I AMPS SUPPLY WASTE A001 i SYS SC{TEC SCi t EC 205T ; I 120/208 W/ HOLD BUTTON 178081 LC 4AMPS 0 240V 105373 I SB E162 2 MACH MACH ESP VERISMO Ti iERMOPLAN 801 208/1 I 37.7 3/8 CWF 1 1893113 PLAYER PLAY 0400 � 1 30 � C400 PLAYER/ Aiv4P/ 186650 SB A009 1 COMBO PKG NETWORK ; 120 I WATTS 140005 PWR STRIP E208 1 A300 2 L _ i I SOS REGISTER STANDARD - SBUX4840 115 j 3.8 ; LC ACCESSORIES AMERICAN I ( I I A602 4 , POS BANK W /225X PIN SECURITIES i i 155279 LC ADDITIONAL ITEMS i J I WWW.TANNOY.COM / I ADL3 3 MUSIC SPEAKERS TAN! 4OY CF1S501 BM € I 1 .519.475.11 58 ! GC (TEM# QTY DESCRIPTION MANUFACTURER 4 MODEL �'# VOLTS I AMPS SUPPLY WASTE REMARKS SKU ## REST'. E004 I 1 GRINDER -- COFFEE 1 DITT#NG ( KR-1203 110 11.8 AT BACKBAR W/ BAG 145182 SB €1RFWIrt'n W"ATFR lz,Y`~TFMi E206 1 BREWER - TWIN AMERICAN C" SYSTEM REFRIGERATOR UC 3/8 NEMA 14- 50R /P; 1 40006 E152 1 COLUMBIA � METALWARE P400E 120/208 36 � C 4AMPS 0 240V 105373 I SB E162 2 MACH MACH ESP VERISMO Ti iERMOPLAN 801 208/1 I 37.7 3/8 CWF 1 1893113 SB i 801 ( VERiSPlO E207 1 T _ SALT TANK G ROUP WATER W"ATFR lz,Y`~TFMi E206 1 WATER SYSTEM "C" 1 WATER SYSTEMS I �- C" SYSTEM REFRIGERATOR UC � 2 DR D 1 40006 SB ICE MACHINE (AIR PROCESSOR IGROUP I I WATER SYSTEM "C" ;WATER SYSTEM i E207 1 T _ SALT TANK G ROUP WATER ; 140005 SB E208 1 WATER SYSTEM "C" C SYSTE M ;CROUP 140003 SB - SOFTENER J REFRIGENA lON /ICE: E301 I I R REFRIGERATOR UC 2 DR D ICE MACHINE (AIR 4 8" DOUBLE ( 115 7 AT BfLRfSTA UNDER 1 10101 SB DOOR ESPRESSO C106HAP 0 /10 13.1 CWF O /10 3 I WITH 500¢# BIN 112639 SB jj CWF B55PSA N/A 109459 SB T I UC4048 15 7 SAFE AS E301 110 SB SELF- CONTAI 208V / 14.5 / W/ FRONT PULL -OUT 181804 SB EYED - HO RIZ. 115V 2.45 AM S REFRIGERATION UNIT TG1 F__ i S LEFT 1 8.5 257006 SB TG2R 2S 11 - 15 10 247029 SB TGIF -1S 1 5 8.5 257003 SB I E451 11 SA NITIZ R HOBART ! LXIH 08 -240 1 120/20 1 38 3/4" H44 3/4-" ID NEMA 14 -50 R/P 181987 SB ' i I E806 13 I COFFEE SHUTTLE ' AMERICAN I METALWARE I CS-1 121 1 I FOR WARMER PAD 85'!003 S8 a } I 3 TEM ## QTY j DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU F`# RESP. c XFMR RETAIL "NE5" TO WEST MAIN GROUND GROUND 8,734A BAR ELECTRODES VD =0.83 - HCEA METER 250.4G 7G � 7G M 1 HEC1 RETAIL HER1 HEV3 RETAIL HEV1 PAD MOUNTED - - CONDO "SE1" RETAIL SKI OP "NE1" LTG/ ICE RINK C RINK 300KVA P HOUSE . T.S - AND MECH SNOWMLT 0OKVA 7G 7G TYPICAL TO EAST - _ _ _ - EAST 120/208V I N I TV5S HCEA SWITCHBOARD HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER G TRANSFORMER ( _ _( m }� m m m I i IscA= 17,140 GFl 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED II 10OA3P 250A3P 250A3P 250A3P 40DA3P 25OA3P 40OA3P 50OA3P 1600.4G I I 160OA3P IsCA= 18,430 L - - - - - - - - - - - - - - - - _ _ _ _ - VD -1'58 1600A COMMERCIAL METER BANK, MDC -HET 277/48OV, 3PH, 4W GENEF�.AL NOTES: SCHEDULE KEY (RESPONSIBILITIES): F GJC PROVIDED BY GENERAL CONTRACTOR INSTALLED BY GENERAL CONTRACTOR F l INS BY GENERAL CONTRACTOR F I NSTALLED RPROVI ERAL CONTRACTOR R FC PROVIDED BY STARBUCKS, INSTALLED BY FIXTURE CONTRACTOR FEEDER SCHEDULE KEY CO DUCTORS "G 250.4 G 4# 250 1# 4 G 3 1600.4 G 5 1 4# 500 1# 4/0 G 3 1/2 I 7 G 1# 310 G 3/4 MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE BUILDING LOAD SUMMARY MDC -HE1, 277/480V 3PH 4W - 2000A BASE BUILDING CALCULATED LOAD 1197 AMPS PANEL NE5 LOAD 102 AMPS TOTAL MDC LOAD 1299 AMPS I _ 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE /DATA /FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7. INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED CONCEPT DRAWINGS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 8. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. TRANSFORMER SCHEDULE KEY (6) HV FLA LV FLA HV PROT (1) HV PROT (1) HIGH VOLTAGE FEEDER (3) LV PROT (2) LV PROT (2) LOW VOLTAGE FEEDER (3) GROUNDING (4) DIMENSIONS (5) WEIGH7 BTUH NOTE 480 V 208 V OCT BRKR SWITCH IFUSE CONDUCTORS I ''C COT BRKR SWITCH JFUSE I "C CNDTRS I "C HIGH I WIDE I DEEP (5) OTPT (5 T112.5 135.3 312.3 1 175 A 3 P 1 3# 2/0 , 1# 6 G 2 400 A 3 PI 1 # 3 G 1 2-1/2 I 1 # 1 /0 3/4 39.25 1 30.00 24.00 725 1 14168 NOTES: 1 .) PRIMARY Q.C. PROTECTION PER NEC 450 -3. 2 •) SECONDARY O.G. PROTECTION PER NEC 450 -3. 3 .) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 4.) BONDING AND GROUNDING CONDUCTOR PER NEC 250 -66. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6 •) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K RATED TRANSFORMERS, 7.) FOR K -RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND /OR LOAD. L3 w M w It 0 Y N F Z O M O o Q O W X O N � C N � Y V Z u _ w ffi CATOR. R1INiA ti AssocIATFs, Co. CONSUTLMNG MECHANIC.AUF.LEC RICAL ENGINEERS 896T80or Sxeel. Lakewood. 00 ?0401.4700 303(232-620-'. Fax 30W33- 0l WaI4 CMto(Mm0.cem. VAwv.04:0rrum0.c0m ASI #1 09/24/07 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENTOF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. ELECTRICAL SCHEDULE SHEET CYO Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- ELS.DWG - SC.2 PLOT 02/25/2010 0 2:08pm REV. 07/13/2007 CAD: )'hafer XREF: tb.dwg E451 11 SA NITIZ R HOBART ! LXIH 08 -240 1 120/20 1 38 3/4" H44 3/4-" ID NEMA 14 -50 R/P 181987 SB ' i I E806 13 I COFFEE SHUTTLE ' AMERICAN I METALWARE I CS-1 121 1 I FOR WARMER PAD 85'!003 S8 a } I 3 TEM ## QTY j DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU F`# RESP. c XFMR RETAIL "NE5" TO WEST MAIN GROUND GROUND 8,734A BAR ELECTRODES VD =0.83 - HCEA METER 250.4G 7G � 7G M 1 HEC1 RETAIL HER1 HEV3 RETAIL HEV1 PAD MOUNTED - - CONDO "SE1" RETAIL SKI OP "NE1" LTG/ ICE RINK C RINK 300KVA P HOUSE . T.S - AND MECH SNOWMLT 0OKVA 7G 7G TYPICAL TO EAST - _ _ _ - EAST 120/208V I N I TV5S HCEA SWITCHBOARD HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER G TRANSFORMER ( _ _( m }� m m m I i IscA= 17,140 GFl 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED II 10OA3P 250A3P 250A3P 250A3P 40DA3P 25OA3P 40OA3P 50OA3P 1600.4G I I 160OA3P IsCA= 18,430 L - - - - - - - - - - - - - - - - _ _ _ _ - VD -1'58 1600A COMMERCIAL METER BANK, MDC -HET 277/48OV, 3PH, 4W GENEF�.AL NOTES: SCHEDULE KEY (RESPONSIBILITIES): F GJC PROVIDED BY GENERAL CONTRACTOR INSTALLED BY GENERAL CONTRACTOR F l INS BY GENERAL CONTRACTOR F I NSTALLED RPROVI ERAL CONTRACTOR R FC PROVIDED BY STARBUCKS, INSTALLED BY FIXTURE CONTRACTOR FEEDER SCHEDULE KEY CO DUCTORS "G 250.4 G 4# 250 1# 4 G 3 1600.4 G 5 1 4# 500 1# 4/0 G 3 1/2 I 7 G 1# 310 G 3/4 MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE BUILDING LOAD SUMMARY MDC -HE1, 277/480V 3PH 4W - 2000A BASE BUILDING CALCULATED LOAD 1197 AMPS PANEL NE5 LOAD 102 AMPS TOTAL MDC LOAD 1299 AMPS I _ 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE /DATA /FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7. INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED CONCEPT DRAWINGS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 8. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. TRANSFORMER SCHEDULE KEY (6) HV FLA LV FLA HV PROT (1) HV PROT (1) HIGH VOLTAGE FEEDER (3) LV PROT (2) LV PROT (2) LOW VOLTAGE FEEDER (3) GROUNDING (4) DIMENSIONS (5) WEIGH7 BTUH NOTE 480 V 208 V OCT BRKR SWITCH IFUSE CONDUCTORS I ''C COT BRKR SWITCH JFUSE I "C CNDTRS I "C HIGH I WIDE I DEEP (5) OTPT (5 T112.5 135.3 312.3 1 175 A 3 P 1 3# 2/0 , 1# 6 G 2 400 A 3 PI 1 # 3 G 1 2-1/2 I 1 # 1 /0 3/4 39.25 1 30.00 24.00 725 1 14168 NOTES: 1 .) PRIMARY Q.C. PROTECTION PER NEC 450 -3. 2 •) SECONDARY O.G. PROTECTION PER NEC 450 -3. 3 .) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 4.) BONDING AND GROUNDING CONDUCTOR PER NEC 250 -66. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6 •) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K RATED TRANSFORMERS, 7.) FOR K -RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND /OR LOAD. L3 w M w It 0 Y N F Z O M O o Q O W X O N � C N � Y V Z u _ w ffi CATOR. R1INiA ti AssocIATFs, Co. CONSUTLMNG MECHANIC.AUF.LEC RICAL ENGINEERS 896T80or Sxeel. Lakewood. 00 ?0401.4700 303(232-620-'. Fax 30W33- 0l WaI4 CMto(Mm0.cem. VAwv.04:0rrum0.c0m ASI #1 09/24/07 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENTOF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. ELECTRICAL SCHEDULE SHEET CYO Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- ELS.DWG - SC.2 PLOT 02/25/2010 0 2:08pm REV. 07/13/2007 CAD: )'hafer XREF: tb.dwg XFMR RETAIL "NE5" TO WEST MAIN GROUND GROUND 8,734A BAR ELECTRODES VD =0.83 - HCEA METER 250.4G 7G � 7G M 1 HEC1 RETAIL HER1 HEV3 RETAIL HEV1 PAD MOUNTED - - CONDO "SE1" RETAIL SKI OP "NE1" LTG/ ICE RINK C RINK 300KVA P HOUSE . T.S - AND MECH SNOWMLT 0OKVA 7G 7G TYPICAL TO EAST - _ _ _ - EAST 120/208V I N I TV5S HCEA SWITCHBOARD HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER HCEA METER G TRANSFORMER ( _ _( m }� m m m I i IscA= 17,140 GFl 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED 100% RATED II 10OA3P 250A3P 250A3P 250A3P 40DA3P 25OA3P 40OA3P 50OA3P 1600.4G I I 160OA3P IsCA= 18,430 L - - - - - - - - - - - - - - - - _ _ _ _ - VD -1'58 1600A COMMERCIAL METER BANK, MDC -HET 277/48OV, 3PH, 4W GENEF�.AL NOTES: SCHEDULE KEY (RESPONSIBILITIES): F GJC PROVIDED BY GENERAL CONTRACTOR INSTALLED BY GENERAL CONTRACTOR F l INS BY GENERAL CONTRACTOR F I NSTALLED RPROVI ERAL CONTRACTOR R FC PROVIDED BY STARBUCKS, INSTALLED BY FIXTURE CONTRACTOR FEEDER SCHEDULE KEY CO DUCTORS "G 250.4 G 4# 250 1# 4 G 3 1600.4 G 5 1 4# 500 1# 4/0 G 3 1/2 I 7 G 1# 310 G 3/4 MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE BUILDING LOAD SUMMARY MDC -HE1, 277/480V 3PH 4W - 2000A BASE BUILDING CALCULATED LOAD 1197 AMPS PANEL NE5 LOAD 102 AMPS TOTAL MDC LOAD 1299 AMPS I _ 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE /DATA /FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7. INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED CONCEPT DRAWINGS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 8. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. TRANSFORMER SCHEDULE KEY (6) HV FLA LV FLA HV PROT (1) HV PROT (1) HIGH VOLTAGE FEEDER (3) LV PROT (2) LV PROT (2) LOW VOLTAGE FEEDER (3) GROUNDING (4) DIMENSIONS (5) WEIGH7 BTUH NOTE 480 V 208 V OCT BRKR SWITCH IFUSE CONDUCTORS I ''C COT BRKR SWITCH JFUSE I "C CNDTRS I "C HIGH I WIDE I DEEP (5) OTPT (5 T112.5 135.3 312.3 1 175 A 3 P 1 3# 2/0 , 1# 6 G 2 400 A 3 PI 1 # 3 G 1 2-1/2 I 1 # 1 /0 3/4 39.25 1 30.00 24.00 725 1 14168 NOTES: 1 .) PRIMARY Q.C. PROTECTION PER NEC 450 -3. 2 •) SECONDARY O.G. PROTECTION PER NEC 450 -3. 3 .) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 4.) BONDING AND GROUNDING CONDUCTOR PER NEC 250 -66. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6 •) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K RATED TRANSFORMERS, 7.) FOR K -RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND /OR LOAD. L3 w M w It 0 Y N F Z O M O o Q O W X O N � C N � Y V Z u _ w ffi CATOR. R1INiA ti AssocIATFs, Co. CONSUTLMNG MECHANIC.AUF.LEC RICAL ENGINEERS 896T80or Sxeel. Lakewood. 00 ?0401.4700 303(232-620-'. Fax 30W33- 0l WaI4 CMto(Mm0.cem. VAwv.04:0rrum0.c0m ASI #1 09/24/07 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENTOF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. ELECTRICAL SCHEDULE SHEET CYO Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- ELS.DWG - SC.2 PLOT 02/25/2010 0 2:08pm REV. 07/13/2007 CAD: )'hafer XREF: tb.dwg SCHEDULE KEY (RESPONSIBILITIES): F GJC PROVIDED BY GENERAL CONTRACTOR INSTALLED BY GENERAL CONTRACTOR F l INS BY GENERAL CONTRACTOR F I NSTALLED RPROVI ERAL CONTRACTOR R FC PROVIDED BY STARBUCKS, INSTALLED BY FIXTURE CONTRACTOR FEEDER SCHEDULE KEY CO DUCTORS "G 250.4 G 4# 250 1# 4 G 3 1600.4 G 5 1 4# 500 1# 4/0 G 3 1/2 I 7 G 1# 310 G 3/4 MEC SEE MECH'L EQUIPMENT SCHEDULE XFMR SEE TRANSFORMER SCHEDULE BUILDING LOAD SUMMARY MDC -HE1, 277/480V 3PH 4W - 2000A BASE BUILDING CALCULATED LOAD 1197 AMPS PANEL NE5 LOAD 102 AMPS TOTAL MDC LOAD 1299 AMPS I _ 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE /DATA /FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7. INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED CONCEPT DRAWINGS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 8. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. TRANSFORMER SCHEDULE KEY (6) HV FLA LV FLA HV PROT (1) HV PROT (1) HIGH VOLTAGE FEEDER (3) LV PROT (2) LV PROT (2) LOW VOLTAGE FEEDER (3) GROUNDING (4) DIMENSIONS (5) WEIGH7 BTUH NOTE 480 V 208 V OCT BRKR SWITCH IFUSE CONDUCTORS I ''C COT BRKR SWITCH JFUSE I "C CNDTRS I "C HIGH I WIDE I DEEP (5) OTPT (5 T112.5 135.3 312.3 1 175 A 3 P 1 3# 2/0 , 1# 6 G 2 400 A 3 PI 1 # 3 G 1 2-1/2 I 1 # 1 /0 3/4 39.25 1 30.00 24.00 725 1 14168 NOTES: 1 .) PRIMARY Q.C. PROTECTION PER NEC 450 -3. 2 •) SECONDARY O.G. PROTECTION PER NEC 450 -3. 3 .) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 4.) BONDING AND GROUNDING CONDUCTOR PER NEC 250 -66. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6 •) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K RATED TRANSFORMERS, 7.) FOR K -RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND /OR LOAD. L3 w M w It 0 Y N F Z O M O o Q O W X O N � C N � Y V Z u _ w ffi CATOR. R1INiA ti AssocIATFs, Co. CONSUTLMNG MECHANIC.AUF.LEC RICAL ENGINEERS 896T80or Sxeel. Lakewood. 00 ?0401.4700 303(232-620-'. Fax 30W33- 0l WaI4 CMto(Mm0.cem. VAwv.04:0rrum0.c0m ASI #1 09/24/07 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENTOF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. ELECTRICAL SCHEDULE SHEET CYO Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- ELS.DWG - SC.2 PLOT 02/25/2010 0 2:08pm REV. 07/13/2007 CAD: )'hafer XREF: tb.dwg BUILDING LOAD SUMMARY MDC -HE1, 277/480V 3PH 4W - 2000A BASE BUILDING CALCULATED LOAD 1197 AMPS PANEL NE5 LOAD 102 AMPS TOTAL MDC LOAD 1299 AMPS I _ 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE /DATA /FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 7. INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED CONCEPT DRAWINGS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. 8. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. TRANSFORMER SCHEDULE KEY (6) HV FLA LV FLA HV PROT (1) HV PROT (1) HIGH VOLTAGE FEEDER (3) LV PROT (2) LV PROT (2) LOW VOLTAGE FEEDER (3) GROUNDING (4) DIMENSIONS (5) WEIGH7 BTUH NOTE 480 V 208 V OCT BRKR SWITCH IFUSE CONDUCTORS I ''C COT BRKR SWITCH JFUSE I "C CNDTRS I "C HIGH I WIDE I DEEP (5) OTPT (5 T112.5 135.3 312.3 1 175 A 3 P 1 3# 2/0 , 1# 6 G 2 400 A 3 PI 1 # 3 G 1 2-1/2 I 1 # 1 /0 3/4 39.25 1 30.00 24.00 725 1 14168 NOTES: 1 .) PRIMARY Q.C. PROTECTION PER NEC 450 -3. 2 •) SECONDARY O.G. PROTECTION PER NEC 450 -3. 3 .) ALL CONDUCTORS ARE COPPER. SEE PLANS FOR INCREASED CONDUCTOR SIZES DUE TO VOLTAGE DROP ETC. 4.) BONDING AND GROUNDING CONDUCTOR PER NEC 250 -66. 5.) DIMENSIONS, WEIGHTS & BTUH OUTPUT SHOWN ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY VARY FROM MANUFACTURER TO MANUFACTURER. 6 •) BRANCH CIRCUITS TO HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT ON K RATED TRANSFORMERS, 7.) FOR K -RATED TRANSFORMERS, PROVIDE PARALLEL NEUTRAL CONDUCTORS LUGS AT TRANSFORMERS, LOW VOLTAGE PANELBOARD, DISCONNECTS AND /OR LOAD. L3 w M w It 0 Y N F Z O M O o Q O W X O N � C N � Y V Z u _ w ffi CATOR. R1INiA ti AssocIATFs, Co. CONSUTLMNG MECHANIC.AUF.LEC RICAL ENGINEERS 896T80or Sxeel. Lakewood. 00 ?0401.4700 303(232-620-'. Fax 30W33- 0l WaI4 CMto(Mm0.cem. VAwv.04:0rrum0.c0m ASI #1 09/24/07 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENTOF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. ELECTRICAL SCHEDULE SHEET CYO Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- ELS.DWG - SC.2 PLOT 02/25/2010 0 2:08pm REV. 07/13/2007 CAD: )'hafer XREF: tb.dwg L3 w M w It 0 Y N F Z O M O o Q O W X O N � C N � Y V Z u _ w ffi CATOR. R1INiA ti AssocIATFs, Co. CONSUTLMNG MECHANIC.AUF.LEC RICAL ENGINEERS 896T80or Sxeel. Lakewood. 00 ?0401.4700 303(232-620-'. Fax 30W33- 0l WaI4 CMto(Mm0.cem. VAwv.04:0rrum0.c0m ASI #1 09/24/07 PERMIT 07/13/07 ISSUED FOR: DATE: THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENTOF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. ELECTRICAL SCHEDULE SHEET CYO Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -126 STARBUCKS \CAD \ELEC \P- ELS.DWG - SC.2 PLOT 02/25/2010 0 2:08pm REV. 07/13/2007 CAD: )'hafer XREF: tb.dwg