Loading...
HomeMy WebLinkAboutB10-0112NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES .• TOWNOFVAlI, ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.4792149 ADD/ALT MF BUILD PERMIT Permit #: B10-0112 Job Address: 1370 SANDSTONE DR VAIL Location......: UNIT 8, EIGER CHALETS Parcel No....: 210312103008 OWNER LOPEZ, IVAN 05/18/2010 PO BOX 6852 AVON CO 81632 APPLICANT HOLM CONSTRUCTION INC. P. O. BOX 5356 VAIL CO 81658 License: 122-A CONTRACTOR HOLM CONSTRUCTION INC. P. O. BOX 5356 VAIL CO 81658 License: 122-A Description: REMODEL TOWNHOME Occupancy: IRC Type Construction:IRC 05/18/2010 Phone:970-390-1315 05/18/2010 Phone: 970-390-1315 Project #: Valuation: Total Sq Ft Added: Status . . : Applied . . : Issued . .. : Expires . ..: PRJ10-0068 ISSUED 05/18/2010 O6/08/2010 12/05/2010 $155,000.00 0 ............................................«.,,....,........._..........,...,,.. FEE SUMMARY ...,,........,,..................,..._,,.._...................._._..,,,.,..,.., Building Permit Fee------> $1,301.75 Will Cal Fee---------------------> $4.00 Total Calculated Fees-------------> $5,051.89 Plan Check--------------------> $846.14 Use Tax Fee---------------------> $2,900.00 Additional Fees-----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTA� PERMIT FEES------------> $5,051.89 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments-------------°----------------> 35,051.89 Total Calculated Fees--------> $5,051.89 BALANCE DUE------------------------> �0.00 ..............................................................................................«.........___.............._,_....._..,.........,...,..,.,.,,....,_.__...............,..., DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00AM-4•�� �0 Signature of Owner or Contractor ate ��� -(-� ��, Print Name bld_a It_constructio n_pe rm it_041908 fiXwkN#i�t#ttiftfA�A�/w#X/f�f�fxfff�fwftft�wwwXrtwN��#fw��}Rf4fwfwxxx/wMwttwww##w�iwff*f#�wRtw*wYwkit#xXxffwwwl���#�����f4#f##!ff*#ffx**f*wf#wfYrttN�ffl4kkkkwkkrtMkw�wwww##rtwfw#wwwwkwwk APPROVALS Permit #: B10-0112 as of 06-08-2010 Status: ISSUED 4t44ff tii�triff�ttr4fw�1'i1'ti(�ffRHff}��4�R1rRRrtA'trYlYri't�kfff*4RA4RRRf�f�R#tf fffrtf'YrM'kft*1`441`1`fft`Rtktrf�ffRf4�ktitLYrYtlii(f#iffifl`i*iF4�RYi4rt4�kttYe�kYf�L#t*ii(f#*4}wffe4A�R*fekRrtfiil'�RYeiFikfYrtfti#t441�4ff1�44f�fflw+� Item: 05100 BUILDING DEPARTMENT 06/07/2010 CG Action: AP Item: 05400 PLANNING DEPARTMENT 05/20/2010 bgibson Action: AP 05/20/2010 bgibson Action: AP Plans routed to E-5. Item: 05600 FIRE DEPARTMENT 05/19/2010 mvaughan Action: APCR provide detail on fireplace flue reconstruction. Monitored fire alarm system shali be made to prevent false alarms during renovation. modifications to system shall require fire alarm permit through VFES. rtiMf�kMA'w4rte/A'�k44i(�k444Lf4f4��fftf4wtMfNMfi1'YrY�F�k#'�kYLRf44f##i!ilL444l41ff�f�,l�eftw4#iYReyrlrw4RtrfiRfrrthi4w'fffYr#'i1'YrYrir�kf4f �lff+f*f(tix*M:Yit�RttiiYr4M9'rt�FYrwf�krt4Nllr�kff i(#f1f##i1(iF4++#R1(l4�Rf4ff�fR*krtKkRYr##'i1'f#wf See the Conditions section of this Document for any that may apply. b I d_a It_co n st ru ct i o n_pe rm it_041908 •lfffftxi�xwrtwfw�fxft4xf�f}ttrtf�k���A+w#ffw}f�kwYkYk�f�iff�fR3x�lfwffwkwwYYww4fklftlR���ffMNfFwwwwltfkt#�f##fff*twwiwwwtkkifltt#*f##t*ffxxxkN/Nwfffifftwwktfiffftfi#tfexf�w�ff�R�ffwktf CONDITIONS OF APPROVAL Permit #: B10-0112 as of 06-08-2010 Status: ISSUED ........................................................................................................................................................»..,.,,,,,.....,,,,......,,., Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 16 (BLDG 2003): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC. Cond: 18 (BLDG 2003): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 bld_a It_constru ction_pe rm it_041908 ****************************************************+***�**********+*********�************++ TOWN OF VAIL, COLORADO Statement *********************************�******�*********++*****************+********************** Statement Number: R100000640 Amount: $4,205.75 06/08/201001:52 PM Payment Method: Check Init: SAB Notation: 4252 HOLM CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B10-0112 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2103-121-0300-8 Site Address: 1370 SANDSTONE DR VAIL Location: UNIT 8, EIGER CHALETS Total Fees: $5,051.89 This Payment: $4,205.75 Total ALL Pmts: $5,051.89 Balance: $0.00 **************�********************�***�*********************************+****************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 1,301.75 UT 11000003106000 USE TAX 4°s 2,900.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- +**r***�******�**************************************************�******+******��*****��**** TOWN OF VAIL, COLORADO Statement �**�*�*�**s**�**�********�***�***r**********r******************s«***:****«*�**+**+*�*****+** Statement Number: R100000497 Amount: $846.14 05/18/201002:01 PM Payment Method: Check Init: JLE Notation: 4238 HOLM CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B10-0112 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2103-121-0300-8 Site Address: 1370 SANDSTONE DR VAIL Location: UNIT 8, EIGER CHALETS Total Fees: $5,051.89 This Payment: $846.14 Total ALL Pmts: $846.14 Balance: $4,205.75 **r****r**********************************sss**********s�**********************************s ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 846.14 BUILDING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: I3so ���r ►�� D��� � (Number) (Street) (Suite #) Building/ComplexName: ���E� ��1 7 Contractor I formation: Company: ��/��1 ��C � _ � �L- Company Address: � - O �a%� �3 J� City: V �'�— State: �� Zip: � �t� �� Contact Name: _ L.��p � '�L� Contact Phone: Q�a '-�� `-13 �s E-Mail �'lC1\ ���Ut�,�� A� O�y�(dtn � �� t�. Town of Vail Contr or Re istration No.: � 2�'-�1. X Contra r Signature (required) Property Information ��� #� ?lU�� 2l D3�f� (For parcel #, contact Eagle County Assessors Office at �sit www.eaglecounty.usJpatie) Tenant Name: � V�J C,O �� Z Owner Name: ( U 1+'�� �O P�Z- Valuations (Labor S� Materials) e �+ Building: $ �() . ood ^ �� Plumbing: $ 2� • °�U� Etectrical: $ � b , vo (5 � o� Mechanical: (including fireplace) $ �. ob � � Total: $ ( �J�. 0 a o Office Use: n,� ` �-/ Project #: r 'C�J � � �Q �/� � DRB #: ,I/ ��Q �Q� Building Permit #: �� G� � Z- Lot #: C�lock # Subdivision: � �� Detailed Scope and Location of Work: Q�NpV��� c � O�r '� �'Zst+�-� c� (�v�*a� i' k�no�-S . (use additional sheet if necessary) Work Class: New ( ) Addition ( ) Remodel (f/f Repair ( ) Other ( ) Work Type Interior ( � Exterior ( ) Both ( ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family (� Commercial ( ) Other ( ) Does a Fire Alarm Exist? Yes (� No () Monitored Alarm? Yes ( � No ( ) Does a Sprinkler System Exist? Yes () No ( V� # 8� Type of Existing Fireplaces: Gas Appliances � Gas Log �C Wood/Pellet Wood Buming _ #& Type of Proposed Fireplaces: Gas Appliances 1 Gas Log � Wood/Pellet Wood Burning __...._.. _ __. _ _.___ _ ..._ __._.__. ____...___.__ Date Received: ( Vl Su rd � u. ���v _ �► i5�i� . l �' �l,u� r�.viw C C�C OMC MAY 18 2010 '�,1WtV �F V�11L -Jan-10 �jQ � l IZ Vail Fire Department Asbestos Testing 8� Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from exposure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regulations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testinq required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: Single-Family Dwelling: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Defnition of single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abatement contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: ❑ Will not disturb more than the threshold limits identified above � Tested negative, or at 1% or below (2 copies of test results included) ❑ Tested positive at more than 1%, requires abatement (2 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of � age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and PhaseouY' rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: David Rhoades, Fire Inspector Vail Fire Department 75 S Frontage Rd d rhoades@vai I gov. com 970-477-3454 www.vailpov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303-692-3158 asbestos@state.co.us � � www.cdphe.state.co.us D EIVE MAY 18 2010 �'���!� ��' �.���!�- ♦ 4 EMSL Analyticai, Inc. '✓�G ���) Z 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: (303) 740-5700 Fax: (303) 741•1400 Email: denverlab@emsl.com A�� Quentin Danziger Q Consuiting, Inc. PO Box 997 Vail, CO 81658 Customer ID: Customer PO: R�e��ed: EMSL Order: INES78 12/21l09 11:43 220904027 ���� 1 MAY 18 2010 E' Fax: Phone: (970) 390-0087 " " Project: Elger Chalet �8 EMSL Proj: 't'OW� O� VAIL Analysis Date: 12/21/2009 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance °� Fibrous % Non-Fibrous % Type 01-01 Baler Room White 100% Non-fibrous (other) None Detected z2osaso2�-0o0� Texture Non-Fibrous Homogeneous 01-02 Storage Roan White 1U0% Non-fibrous (other) None Detected zzo9oaoz�-0002 Texture Non-Fibrous Homogeneous 01-03 Laundry Texture White 100% Non-fibrous (other) None Detected � no9oeo2�-000s Non-Fibrous Homogeneous 02-01-Jdnt Baler White Compound Sheetrack/Joint Non-Fibrous zzo9oao2��000a Compound Homogeneous 100% Non-fibrous (other) None Detected 02-01-Drywali Baler Brown/White 10% Ceilulose 90% Non-fibrous (other) None Detected 22osoao2�-0ooaa Sheetrack/Joint Fibrous Compound Heterogeneous 02-02-Jant Gar�age Whfte 100% Non-fibrous (other) None Detected Compound Sheetrock/Joint Non-Fibrous 2zosoeoz�-0oos Compound Homogeneous 02-02-Drywall Garage Brown/White 10% Cellulose 90% Non-fibrous (other) None Detected 220904027-0OOSA Sheetrock/Jant Fibrous Compound Heterogeneous Arralyst(s) '' , � � DeCavallas M'�chael (15) Erin Orthun, Laboratory Manager or other approved signatory Due to magnification limitations inherent in PLM, asbestos fibers in tlimensions below the resolu6on cspabiliry of PLM may not be detected. The �imit of tletedion as atated in Ne method is 1%. The abooe test report relates only to the items tested and may not be reproduced in any form without the e�ress writtan approval of EMSL An�ytical, �nc. EMSL's liabiliry is limited to Me cost of analysis. EMSL bears no reaponsibiliry for sample collection actiHties or analytical method limitadons. Interpretation antl use of test results are the responsibility of the Gient. Samplas recei�ed in gootl condition unleas othen+ise noted. This report must not be used to claim product endorsement by NVLAP or any agency of tha U.S. Go�emment Test Report PLM-7.12.0 Printed: 12/21/2009 11:10:55 AM � , EMSL Analytical, inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: �303) 740-5700 Fax: (303) 741-1400 Email: denverlab�aemsl.com An�: Quentin Danziger Q Consulting, Inc. PO Box 997 Vail, CO 81658 Fax: Phone: (970) 390-0087 Prqect: Elger Chalet �8 Customer ID: Customer PO: Received: EMSL Order: EMSL Proj: Analysis Date: INES78 12/21/09 11:43 AM 220904027 12/21 /2009 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type 02-03-Jant Laundry White 100% Non-fibrous (other) None Detected Compound Sheetrack/Jant Non-Fibrous zzos000z�-0ooe Compound Homogeneous 02-03-Drywall Laundry Brown/White 10°/a Cellulose 90% Non-fibrous (other) None Detected 220904027-0006A Sheetrock/Jant Fibrous � Compound Heterogeneous �03-01 Dark Wood Brown 10% Cellulose 70% Non-fibrous (other) 20% Chrysotile no9oao2�-0o0� Linoleum Fibrous Heterogeneous 03-02 Dark Wood Brown 10% Cellulose 70% Non-fibrous (other) 20% Chrysotile zzosoaoz�-000s Linoleum Fibrous Heterogeneous 03-03 Dark Wood Brown 10°/a Cellulose 70% Non-fibrous (other) 20% Chrysotile zzosoaozi-0oos Linoleum Fibrous Heterogeneous 04-01 Colored Linoleum Various 70% Non-fibrous (other) 30% Chrysotile nosoaoz�-oo�o Fibrous Heterogeneous 04-02 Colored Linoleum Various 70% Non-fibrous (other) 30% Chrysotile 2zosoaoz�-oon Fibrous Heterogeneous Analyst(s) DeCavallas Michael (15) Erin Orthun, Laboratory Manager or other approved signatory Due to magnification limitations inherent in PLM, asbestos fibers in dimensions below the resolution capability of PLM may not be detected. The limit of detedion as stated in the method is 1%. The abo�ne test 2port relates only to the items tested and may not be reproduced in any fortn wit�out the e�ress written approval of EMSL Analytical, Inc. EMSL's liability is limited to the cost of analysis. EMSL bears no responsibility for sam ple collection actitifies or analytical meNod limitations. Interpretation and use of test resutts a2 the responsibiliry of the client. Samples receieed in good condi6on unless othenvise noted. This 2port must not be used to claim product endorsement by NVLAP or any agency of the U.S. Go�emment. Test Repart PLM-7.12.0 Printed: 12/21/2009 11:10:58 AM 2 r . EMSL Analytical, Inc. 7330 S. Alton Way Building 12 Suite A, Centennial, CO 80112 Phone: (303) 740-5700 Pax: (303) 741-1400 Email: denverlab@emsl.com A�"� Quentin Danziger Q Consulting, Inc. PO Box 997 Vail, CO 81658 Fax: Project: Elger Chalet #8 Phone: (970) 390-0087 Customer ID: Customer PO; ReCeived: EMSL Order: EMSL Proj: Analysis Date: INES78 12/21/09 11:43 AM 220904027 12/21/2009 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbe s Sample Description Appearance % Fibrous % Non-Fibrous % Type 04-03 Colored Liraleum Various 70% Non-fibrous (other) 30°r6 Chrysotile zzosoaoz�-ooi2 Fibrous Heterogeneous Arralyst(s) DeCavallas Michael (15) r'' - , ' . Erin Orthun, Laboratory Manager or other approved signatory Due to magnification limitations inherent in PLM, asbestos fibers in dimensions balow the resolution capability of PLM may not be detected. The limit of detection as stated in the method is 1%. The abooe test report relates only to the items tested and may nat be reproduced in any fartn without the e�ress written approval of EMSL Analytical, Inc. EMSL's liability is limited to the cost of analysis. EMSL bears no responsibility for sam ple collection actiHties or analytical method limitations. Interpretation and use of test results are the responsibility of the Giant. Samples recei�ed in good condition unless othenvise noted. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Gooemment. Test Repart PLM-7.12.0 Printed: 12/21/2009 11:10:59 AM THIS IS THE LAST PAGE OF THE REPORT. 3 ��/fl N L c� Pt.z. ic�t:5 � 1��N�.E=i LIGHT FIXTURE SCHEDULE lune5th?010 LOPEZ RES[DENCE __ ___ __ _ _ _ _ _ _. . . _ _ _ _ _ rPE Tag Description Manufacturer 'Model MfgrNo. Lamp(s) Accesorv(ics)/Commen[s � -- -_____. . . .. ... . . . - --- --- -. _ .. . . _ . . .. . __.. . . . ._ . .. . . _ __ _ ._.. _ _ . . . _ .. ._ . . . _ _ . . _-.__. _. .__ _.. ._--. _. _ . . . _ . . . . _. _ A Reccssed adjustable downlight __. Cooper RSA_ ___ . ComboLight � . G-A-037M 16-M-I-N-R-B-N _. .( I) 370.' MRI6 � IC Rated Housing: Integral Transformer, Mud-ln Trimless (Note: SOW mac) _. . _. _.. . _-___ ._ . _ ._.. . ... ..... ....... . _ ... ._----. _. __ .. ..______. ..-- -._-.___ - ---- -.._- _.__ _ _._._..._.. � B '.Recessedadjustabledownlight Cooper RSA �.ComboLight �C2-A-037M16-M-I-N-R-B-N (1) 37W MRI6 �� IC Rated Housing; Integral Transformer, Mud-In Trimless (Note: SOW ma�c) �� � ��� ._ ;-_. �- - ___-------_.. _.____- _ __-- _.._ _ _. �----__. ___ ___-._._ ..__..__ . . _-..___ _ .. _ . _ . _. .---.. _. . ----. . .-- ---- --- . _ _.... . . _. --- ---.. __ _.. . . . _ __-_ -_ _ _.--- _ _ . p� ��. Recessed downlight Halo � Eco-Twist H?78[CAT w'404C Specular Clear Trim ( I � 16.21 or 28W Low� Pmfile Spiral i'�vist ' IC Rated Housing: Non-dimable ballast v rwii ��C I. � Compact Fluorescent Zv�- -' ---. ._ .__. ___.---__ _ . .__.____ . . _. . _..__ .. .. .. _.__ . _-__ . . . .. _ __.. . ._.___... __ . ._. __ __.___. . _ ._____ _.__ - ___ __. _. .. ... .. ._... .. .. _ . �� � v�.. D Wazeryroof adjustable shower light Juno . ICPL426E_ Smes Housing ICPL426E Series Housing w!441 W-SC Trim ( I) 28 W 2JOOK CPL 3 mbe lamp __ IC Air-Loc Housing u�- �5 edg Adj.; Crome Trim Ring�Clear Lens ���� Prosted Ring , _ .._. __._.-----_. .__. _. ___- __... ____... . ... . _ _ .. ._ . _ _._. _. _. ---- ----- � � ---.. . _... _.--. ..__ . . . ... _. . .. _. ._. . .... ww � . . . . � __. .. __ _ . . _ . _._ . u a s �aee�„�;:�,,,;s �� � ��--r-.-�-°� �,,.n.� �„� F - - - -- - - - - _ _ _ _ _ - - - - __ _ __ __ ¢ �'. F Wa11�Sconce . .-... -. . '�Energie ��Zrn T2 wi 7'NB Ribbed . .. .�. (1) SOW MRI6 . . ..... Mowt fixture with bottom edge 6" A.F.F. .. . - . .....--��- - -..... .. a��. � . � . '�.. Reflector � ZT'N 4"x 13" Zenn 120V '�. . . :_. .._ ._._ .._ -- -._.. _.. . . . . _ ..--. ... _. .�.. . _ _.. ._. _. _ _._- . _. _._ . ..._-- . .. ----.____.. _..__ ._ ----- .__ ...__--------- __. _ _. ._ _ ._._. __ r�n .G � Wall Sconce iT.B.D. �I'.B.D. T.B.D. T.B.D. .T.B.D. � -� - - � � �'� '--__ ------ -_ . _.___._ -____ .:__._- � --- ---- -----_. ._. .__.------ ---... .___ .. . .---------_ . _._ ___... ___--� . ._. . .._. . . _._. . . . __. . �; _..---- - _ .. _--- ._. _ � -�i �,H Wall Sconce ; P.B.D. �,'C.B.D. '�T.B.D. T.B.D. T B.D. � Q;- . ..._- --__ __-. ___.---- -----. .___ .. ___. _ _ .. . .. ____ _ . . _.- - -. __ .__ ._--- . ___ . _- ..- ._---- -----_ -_- _ _ _. . . _ --- -- � 3'� Hl Wall Swnce (Fluorescent) T B.D. ,T B D T.B.D. T B D. � �T B.D. ._ _ '� _ . _.. ._.- ._ ...- . . ___-- ._- �---------_ __-_ _ .__�; . . _ _. ... _ . . � - --..- ---_.. _._ _ .__- ... -----_ . . . _.._ ---- ---- -- _ .. . .._._._------ �_-___ - ----- --._____----- --- . . .. ----- . . _ . �� [ Cove Lighting ___ __ _ LEDTromcs __. .._ .. LHDString � LEDStrmgs05; SOmm spacing_ Wazm White ( I)LED Lamp!SOmm I Provide Dimable Drivers & Power Supplies as req'd ��_ . _.. . . ... _ _ .. . _- ___ ._ . . _.- --- -- - .... . - -__.. _----__ _--- ---_ ._ . _ _ . ---- .__.- -.. .- ----- ---- -_._. . . .--- --____ _.. . ____ . .__ ._- . ___.__ __-- -_.. _._._ ._- ---__ _._ .__..--- -- - ... ---� -+ _._ .___- � -- -- ---- -- - � -- ----- --- ---- '�,J SurfaceMoun[edFlourescent Nulite �SFSeries SF-2?SWTB-120-IS-L-WH 25WT83500K .. ___._ ______ ..._.. _---- -- _._ ��- - � � ---... ... _ -__ ____. --- .__ ____.___... . _... _-_- _----__ .... ._...- ----.___ .__. .._- ._ ____ .___ ..;- -- - - -._ _ .. ._ � ..-- -- --- -- - - -- -- - �- t ---- --- - — --_ ._ ___ ___ . . �� K Undercabmet Lighhng CSL CounterAttack __ NCAX-I �0 (�mfv len�ths rea'd) Whue w- Lense Xwon Halogen Lamps �� I _ .._ . __ .__.. . .. _ ..-- -- •_. _ . . _ �-- ----- - . .. . .. _. .... _-- -_ . . _- � ------ ,_,�L Stem-MountedlncandescentTrack ... .� __ ,T.BD-.. -----.._ _ �T.B.D. �------_ -�--- - �T.B_D._ . .._ .... ___-_ _...� TB.D_ - ---- ---._ ___-_ I�TB.D. --- ... ---- ... .... . ____ __....� . -- ---_ _._..__I 1 ... '- -_.__._----- - - -___.__. ----. ..-------- ._.�- --..___ _... .----'-- . _---- ----- _ ___ ... .-------- -..__---- .. . . .... .. .. ... ..._ --- _.._ --- - ------ — -_. ___- ------. . _ __.___ _____-- __'�, M_ �I Wall-Mounted Directwoal Lighhng _. __. _ i BK Lighhng ___ ._ : S�gn Lite �. SN-8-SAP 9-B-18-C w% Remote Transfortner , SOW MR16 EXN (40 deg J Flood Lamp_ __�Ploished aluminum Fin., Clrae Lens; I8 Stem; Remote Transfortner � � � � v V I � � � 0�0 ,�JL 12 Z TOW� o� �AIL . r,, , O � � �l � � I J C D H1 IECC 2009 Fixture Count Lamp Type Quantity Tag Lamp Type LED 8 A Incandescent Linear Fluorescent 4 B Incandescent CFL 21 F Incandescent CFL 6 G Incandescent Linear Fluorescent 2 K Incandescent L Incandescent M Incandescent Total High Percer Hi 41 51.90% Total Other: �, 1 3 8 1 1 1 � � � � � � � � DESCRIPTION An adjustable Recessed fixture with a trimless insert suitable for downlighting and accent applications. Utilizes ONE (1) 12V MR16 lamps. For new construction applications in insulated ceilings. Rated for direct contact with insulation material. SPECIFICATION FEATURES A... Housing Housing and plaster frame: 18 gauge CRS with flat black powder coated internal finish. Perforated meshplate allows for trimless installation in drywalVplaster ceilings by allowing the ceiling's mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled "kn'rfe-edge" lips to ensure a clean edge. Can accommodate 0.50" to 1.25" ceiling thickness. B... System Protection: Thermal protection provided to guard against overheating. C... Junction Box Integral j-box and low vottage (12� electronic, magnetic or toroidal transformec 120V input, 12V output. Junction box is U.L. listed for through branch wiring. Includes five 1/2 trade size knockouts. * io.oa° D... Lamps One (1) 12V MR16 lamp mounted in adjustable double gimbal. Lamp holder is individually removable and may be regressed 1" for additional cut-off. lamp can accept up to three optical accessories (i.e. lens + hex louver + snoot). 45° x 45° locking lamp adjustment. Beveled-edge lamp ring is secured with threadless, bayonet action. Optional retractable arm is available for lamp pulldown and extreme aiming. E ... Mounting GOT NAIL hanger bars include pre- installed nails that easily install in regular lumber, engineered lumber, and laminated beams. Safety and guidance system prevents snagging, ensures smooth straight nail penetration and allows bar hangers to be easily removed if necessary. � io.2a° + _ _� i ��.00., ( --.� � Double � Gimbal 45° x 45° ' � Adjust � NOTES: De-Rated wattage labels are available. 12V Primary voltage is available. ORDERING INFORMATION RSA LIGHTING Automatic levelling flange aligns the housing and lets you hold the housing in place with one hand while driving the nails. Housing can be positioned at any point within a 24" joist span. Pass- N-ThruT"" feature allows bar hangers to be shortened without removing from plasterframe. Score lines allow "tooless" shortening for 12" joists. Integral T-bar clip snaps onto T-bars with no additional clips required. F ... Labels cULus listed for IC applications, suitable for use in damp locations. Ceiling Cut-Out: 4.67" x 4.67" � �a.zo° � 12.00" - 24.00" � �� �—'— 10.24 " --� 21.70,• }— -- 77.00„ i _ _ � �— 3.88" - � I � 3.88" � `- �--. � Perforated Meshplate Integral Low Voltage Transformer COMBOLIGHT� Recessed Fixture One (1) Light 12V MR16 50W Max. Air-Tite I.C. Housing w/ Trimless Insert cOua C1 A N N Configuration Lamp Type / Wattage Label Power Supply Lamp Mechanism Trim Insert Finish C1 ` COMBOLIGHT 020M16 = 20 Watt max. MR1612V Voltage G` Double Gimbal N= Trimless Recessed One (1) Light 037M16 ° 37 Watt mau. MR16 12V t=120V R= Retractable Double Gimbal 050M16 = 50 Watt max. MR7612V 2' 27N �OP� Lighting www.cooperl igM ing. com Housing A ° Air-Tite Insulated Ceiling Power Supply E = Electronic Low Voltage Transformer Trim Insert M= Magnetic Low Voltage N= Trimless Transformer Specifications and Dimensions subject to change without notice. RSA LigMing • 7945 Orion Ave. • Van Nuys, CA 97406 • 818-349-3030 • FAX 81 &349-3031 Housing Interior W = White B = Black S' Industrial Silver re� oso�io � �. � � � �� � � �. , � DESCRIPTION An adjustable Multi-lamp Recessed fixture with a trimless insert suitable for downlighting and accent applications. Utilizes TWO (2) 12V MR16 lamps. For new construction applications in insulated ceilings. Rated for direct contact with insulation material. SPECIFICATION FEATURES A... Housing Housing and plaster frame: 18 gauge CRS with flat black powder coated intemal finish. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling's mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled "kn'rfe�dge" lips to ensure a clean edge. Can accommodate 0.50" to 125" ceiling thickness. B... System Protection: Thermal protection provided to guard against overheating. C... Junction Box Integral j-box and low voltage (12� electronic, magnetic or toroidal transformer. 120V input, 12V output. Junction box is U.L. listed for through branch wiring. Includes five 1/2 trade size knockouts. � io.oa•• -� D... Lamps Two (2) 12V MR16 lamps mounted in adjustable double gimbals. Lamp holders are individually removable and may be regressed 1" for additional cut-off. Lamp can accept up to three optical accessories (i.e. lens + hex louver + snoot). 45° x 45° locking lamp adjustment. Beveled-edge lamp ring is secured with threadless, bayonet action. Optional retractable arm is available for lamp pulldown and extreme aiming. E... Mounting GOT NAIL hanger bars include pre- installed nails that easily install in regular lumber, engineered lumber, and laminated beams. Safety and guidance system prevents snagging, ensures smooth straight nail penetration and allows �---_ i o.2a„- —� I �.00° / Double \ Gimbal \45° x 45 % Adjust NOTES: De-Rated wattage labels are available. 12V Primary voltage is available. ORDERING INFORMATION RSA LIGHTING bar hangers to be easily removed if necessary. Automatic levelling flange aligns the housing and lets you hold the housing in place with one hand while driving the nails. Housing can be positioned at any point within a 24" joist span. Pass-N-ThruT"' feature allows bar hangers to be shortened without removing from plasterframe. Score lines allow "tooless" shortening for 12" joists. Integral T-bar clip snaps onto T-bars with no additional clips required. F ... Labels cULus listed for IC applications, suitable for use in damp locations. Ceiling Cut-Out: 4.67" x 8.55" �_ _ ia.2o,. . � 12.00" - 24.00" � � 2i.�o„ 17.00•, _ _ _ }-- 7 75" � i� 3.88" --• - �-- - 3.88" C , a ;' �_::-- , � Perforated Meshplate Integral Low Voltage Transformer COMBOLIGHT� Recessed Multi-Lamp Fixture Two (2) Light 12V MR16 Air-Tite I.C. Housing w/ Trimless Insert cOua C2 A N Configuration Lamp Type / Wattage Label Power Supply Lamp Mechanism Trim Insert Finish C2 = COMBOLIGH7 020M16 = 20 Watt max. MR16 72V Yoltage G= Double Gimbal N= Trimless Recessed Two �2) Light 037M16 = 37 Watt max. MR1612V 1=120V R° Retractable Double Gimbal 2 = 27N �OP� Lighting www.cooperlightinq.com Housing A = Air-Tite Insulated Ceiling Power Supply E = Electronic Low Voltage Transformer Trim Insert M= Magnetic Low Voltage N= Trimless Transformer Specifications and Dimensions subject to change without notice. RSA Lighting • 7945 Orion Ave. • Van Nuys, CA 91406 • 818-742-3838 • FAX 818-7423801 Housing Interior W = White B ° Black S' Industrial Silver �e� oso�io DESCRIPTION Halo"p Eco-Twist'"^ takes energy efficient compact fluorescent lighting to the next generation of technology with a NEW twist compact fluorescent lamp and ballast system. The H2781CAT incorporates this new CFL tech- nology in an insulated ceiling housing rated for direct contact with ceil- ing insulation. The H2781CAT AIRTITE"" housing design prevents airflow between attic and living areas and saves on both heating and air condi- tioning costs.The electronic compact fluorescent ballast is a new multi- wattage design allowing complete interchangeability between 16, 21, and 28 watt lamps. The Halo Eco-Twist system is designed to allow easy transition from energy-consuming incandescent lamps to a new gener� tion of energy-saving, low profile, high color CFLs. Halo Eco-Twist ac- complishes this transition by offering direct compatibility with a wide selection of current Halo trims designed originally for the incandescent "A-lamp° DESIGN FEATURES A...Housing Single wall aluminum housing. Sealed and gasketed for AIRTITE installation, with the ceiling-contact gasket pre-installed on the plaster frame. Can be used in 2"x 8" joist construction. Housing adjusts for ceilings up to 1-3/8" thick B...Plaster Frame Includes regressed locking screw for hanger bars and cutouts for crimping hanger bars in position. C...Junction Box • �isted for through branch circuit wiring • Positioned to accommodate straight conduit runs • Seven 1/2" trade size conduit knockouts with true pry-out slots • Slide-N-Side"" connectors allow non-metallic sheathed cable to be installed without tools and without removing knockouts. Accepts a wider range of non-metallic sheathed cable - the standard cable types used in lighting for both U.S. and Canada. - Allows wiring connections to be made outside the junction box - Simply insert the cable directly into the trap after connections are made - accommodates the following standard non-metallic sheathed cable types: (US) #14/2, #'14/3, #12/2, #12/3 (Canadal #14/2, #14/3, #12/2. D....Bar Hangers Bar Hanger Features include: • Pre-installed nail easily installs in regular lumber, engineered lumber and laminated beams • Safety and guidance system prevents snagging, ensures smooth straight nail penetration and allows bar hangers to be easily removed if necessary. • Automatic levelling flange aligns the housing and lets you hold the housing in place with one hand while driving nails • Housing can be positioned at any point within 24" joist span COO�R Lighting www.cooperlighti ng.com • Pass-N-ThruT"' feature allows bar hangers to be shortened without removing from plaster frame. • Bar hangers do not need to be removed from frame for shortening • Score lines allow "tool-less" shortening for 12" joists • Bar hangers may be repositioned 90° • IntegralT-bar clips snaps ontoT-bars - no additional clips required. E...Socket GZ16q is a 4-pin socket with easyTWIST & CLICK"" locking installation action. The socket allows interchangeable use with 16, 27, and 28 watt lamps. F...Lamp SpiralTwist Compact Fluorescent lamp (purchase separately) • T3 Low Profile SpiralTwist • BaseType: GZ16q (4-Pin base with Twist & Click actio�) • CCT:2700°K • CRI: 86 Lamp Designations • 28 Watt: CF28TW/E/GZ16q/827/LS 1,675 Lumens • 21 Watt: CF21TW/E/GZ16q/827/LS 1,225 Lumens • 16 Watt: CFI6TWJE/GZ16q/827/lS 910 Lumens • Lamp Available: Living Spaces"" brand from Osram Sylvania, and from Halo - see accessories • Over 10,000 hour rated average life • 86 CRI rated lamps with enhanced R9 red that provides excellent color and high visual comfort • Color temperature of 2700°K for warm incandescent-like light p.............. E � . � s F s =- D �� 6 V2' 1lssmml ♦----� Geiling - Opening HALO G...Electronic Ballast Models are provided with a 120Volt, residentially rated, multi-wattage elec- tronic fluorescent ballast.The ballast is rated for interchangeable use with 16, 21, and 28 watt GZ16q base Compact Fluorescent lamps. Ballast is a high frequency electronic type, UL Listed Class P, Type 1 Outdoor. Ballast includes InherentThermal Protection, and end of lamp life protection feature that shuts down the ballast upon lamp failure. H...Air-TiteTM Patent Pending socketinterface main- tains airtight rating of 6" aperture Air- Tite rated trims. Labels • UL Listed for Damp Location • UL Listed wet location with select trims • UL Listed for Direct Contact with Insulation and combustible material • UL listed for FeedThrough • UL, cUL Listed Compliance • State of CaliforniaTitle 24 2008 High Efficacy Compliant • Meets Washington State Energy Code • Meets NewYork State Energy Conservation Construction Code • International Energy Conservation Code High EfFicacy Compliant • CertifiedAlR-TITE"" underASTM-E283 Patents • Housings andTrims may be covered by one or more of the following U.S. Patents and additional Patents Pending. - Housings: 6076788, 6082878, 6147307,6498295 - Trims: 5662413, 6726347, 5673997 � )' fnn�.������. C Top View �; �____ � , � 0 (p', o n � ... . . .. 1191�mZm� ,n� namm] ,... E:.—���. _. � � 26Im�m1 � Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes �',`'��� ',��° ,..� x.: H2781CAT 6" Insulated Ceiling AIR-TITETM' Recessed Housing 6" TRIMS For use with: 16 Watt / 21 Watt / 28 Watt Low Profile, SpiralTwist Compact Fluorescent Lamps Eco-Twist�'` =;� ,�� � 1T "1'�` +IT 16Watt 21Watt 28Watt FOR USE IN INSULATED CEILINGS FOR DIRECT CONTACT WITH INSULATION Energy Data Mia StartingTemp Sound Ratiny ClassA -5°F / -20°C EMI/RFI Emissions FCC 47CFR Part 18 Consumer Limits Input Frequency 60 Hz Power Factor > 0.50 THD < 150% Input Voltage 120V Crest Tactor < 1.7 Ballast factor 1.04 Input Power 18W i sw Input Current 028A max Input Pawer 24W 21W Input Curren[ 0.38A max Input Power 32W 28W Input Current 0.45A max 6��°�!4,Lb� a2/�,,c;�\; ADV090638 ORDERING INFORMATION SAMPLE NUMBER: H2781CAT - 30WAT Order housing , trim, lamp, and accessories separately . Housing � H2781CAT=lnsulated Ceiling �� Housing AIR-TITE�"" 2YEAR LIMITED WARRANTY Energy Star Labeled Recessed Lighting Cooper Lighting 1The Company) warrants this product ("the product") against defects in material or workmanship for a period of [wo years from date of original purchase, and agrees to repair or, at [he company's option, replace a defective product without charge for either replacement parts or labor during such time.This does not include labor to remove or install fixtures.This warranty is extended only to the original purchaserofthe product.A purchasers receipt or other proof of date of original purchase acceptable to the Company is required before warranty performance shall be rendered.This warranty only covers product failure due to defects in materials or workmanship which occurs in normal use. It does not cover the bulb or failure of produc[ caused by accident, misuse, abuse, lack of reasonable care, alteration, or faulty installation, subjecting Ihe product to any but the specified electrical service or any other failure not resulting from defects in materials or workmanship. Damage [o the productcaused by separately purchased, non-Company supplied components or bulbs, and corrosion or discoloration of components are not covered by this warranty.There are no express warranties except as described above. THE COMPANY SHALL NOT BE LIABLE FOR �NCIDENTAI, SPECIAL OR CONSEQUENTIAL DAMAGES RESULTING FROMTHE USE OFTHE PRODUCT OR ARISING OUT OF ANY BREACH OFTHIS WARRANTY. ALL IMPLIED WARRANTIES, IF ANY, INCLUDING IMPLIEDWARRANTS OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATIONTOTHE DURATION OFTHIS EXPRESS WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions or limitations may not apply to you. No other warranty, written or verbal, is authorized by the Company.This warranty gives you specific legal rights, and you may also have other rights which vary from sta[e to state.To obtain warranty service, please write to Cooper Lighting, 1121 Highway 74 South, Peachtree Ciry Georgia 30269. Enclose product model number and problems you are experiencing, along with address and telephone number.You will then be contacted with a solution or a Return Goods Authorization number and full instruc[ions for returning the product. All returned products must be accompanied by a Re[urn Goods Authorization Number issued by the Company and must be returned freight prepaid. Any product received without a Return Goods Authoriza[ion Number from the Company will be refused. Cooper Lighting is not responsible for merchandise damaged in transit. Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed. Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them. / COOPER Lighting H2781CAT Trims Reflectors, Wall Wash, Baffles, Adjustable, Lensed (Shower Rated) REFLECTORS � � ��1� �. ��� SuperTrim - AIR-TITE'"' 30CAT=Specular Clear, Air-Tite 30HAT=Haze, Air-Tite 30RGAT=Residential Gold, Air-Tite OD: 7 1/4' (184mm) SuperTrim - AIR-TITETM 30SBAT=Specular Black, Air-Tite OD: 7 1/4' (184mm) Specular Reflector 404C=SpecularClear 404H=Haze 404SN=5atin Nickel 404AC=Antique Copper 404TBZ=Tuscan Bronze 404RG=Residential Gold OD: 7 1/4' (184mm) Specular Reflector 405SC=SpecularClear 405H=Haze 405RG=Residential Gold 405CG=Champagne Gold OD: 7 1/4' 1184mm) White Cone Reflector - AIR-TITETM �� EHT712=White Reflector Cone, High Gloss Appliance White ERT712 ERT712T5=White Reflector Cone, High Gloss Appliance White w/ Torsion Springs OD: 7 1/4' (184mm) BAFFLES SuperTrim -AIR-TITETM' 30PAT=BIack Baffle 30WAT=White Baffle 30WATH=White Baffle, Clear Reflector 30 30SNAT=Satin Nickel, Air-Tite 30ACAT=Antique Copper, Air-Tite 30TBZAT=Tuscan Bronze, Air-Tite OD: 7 1/4' (1S4mm) Full Cone Metal Baffle -AIR-TITETM ERT713=61ack Metai Baffle, High Gloss Appliance White Trim Ring w/ Friction clips ERT773 ERT713WHT=White Metal Baffle, High Gloss Appliance White w/ Friction ciips EflT713TS=61ack Metal Baffle, High Gloss Appliance White Trim Ring w/ Torsion Springs ERT713WHTTS=White Metal Baffle, High Gloss Appliance White w/ Torsion Springs OD: 7 1/4' (184mm) � Full Cone Metal Baffle -AIR-TITETM (Taller height than ERT713 for deeper lamp ERT713L regression) EFT713L=BIack Metal Baffle, High Gloss Appliance White Trim Ring w/ Friction clips ERT713LTS=61ack Metal Baffle, High Gloss Appliance White Trim Ring w/Torsion Springs OD: 7 1/4' (184mm) ADJUSTABLES � Eyeball - 30°Tilt 78P=White Eyeball 78SN=5atin Nickel 78 78B=6rass Eyeball 78AC=Antique Copper 78TBZ=Tuscan Bronze 78P6=Polished Brass Eyeball 78PAT=White Eyeball IAIR-TITE) OD: 8' (203mm) ��� � � ERT704 DIFFUSERS C�� 171 Coilex Regressed Eyeball 420P=BIack Baffle, White Eyeball 420P6=61ack Baffle, Polished Brass Eyeball 420W=White Baffle, White Eyeball OD: 7 1/4' 1184mm) Eyeball ERT704=High Gloss Appliance White Trim Ring w/ White Eyeball ERT704PB=Polished Brass Trim w( Polished Brass Eyeball OD: 8' (203mm) Drop Opal Lens - Glass 171P=White Trim Ring 171PS=White Trim Ring Shower Light OD: 8' 1203mm1 �/ Dome Lens - Glass 772PS=White Trim Ring, Shower Light 172ACS=Antique Copper Trim Ring, ��Z Shower Light 172SNS=Satin Nickei Trim Ring, Shower Light 172TBZS=Tuscan Bronze Trim Ring, Shower Light OD: 7 3/4' (197mm) �� Baffle Wall Wash 430P=BIack Baffle, White Scoop, White q3p Trim Ring 430W=White Baffle, White Scoop, White Trim Ring OD: 7 1/4' (184mm) Accessories (Order Separately) Lamp: ti� Compact Fluorescent lamps, GZ76q base t•- 7216= 16 Watt, 910 Lumens: CF16TW/E/GZ16qB27/LS lamp '� Z221=21 Watt, 1225 Lumens: CF21TW/ElGZ16q/827/LS lamp ..,�__. :a�'� Z228=28 Watt, 1675 Lumens: CF28TW/E/GZ16q/82�/LS lamp -� �� MetalTrim Rings Compatible with 404 and 405 trims TRM6P= White Metal TRM6PB= Polished Brass TRM6C= Chrome TRM6M8= Black Metal TRM6SN= Satin Nickel TRM6TBZ=Tuscon Bronze TRP7M6= Black Plastic OversizeTrim Rings For use when ceiling opening is cut too large. 0T403P is compatible with 404 and 405 trims. For other trims 0T400P or OT403P may be placed behind existing trim ring to hide cut-out irregularities. 0T400P=9 1/4' White Metal OT403P= 8' White Plastic Note: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1 B8 905.5074000 FAX 905.568.7049 � �, • SYLVANIA exclusive CFL phosphor formulation provides enhanced rendition of the strong red color (CIE R9) generating richer, warmer, redder color tones • Energy saving alternative to incandes- cent lamps saves up to 75% energy compared to similar lumen output incandescent • Long life: 12,000 hour average rated life • TCLP compliant • ENERGY STAR° qualified (13W only) SYLVANIA introduces a new family of compact fluorescent lamps with enhanced phosphor technology. These new micro-mini Twist lamps not �'' � only have all benefits of the standard micro-mini product (instant on, low levels of inercury <1.5mg, small form factor) they are also designed �amp Type Micro Mini Twist to provide improvetl rendering of warm tones and strong red colors. The impact of this improved color performance is not reflected in the Color Rendering Index (CRI). That metric does not include rendering of strong red colors. Truly with Living Spaces enhanced warm tone rentlering... THIS IS NOT YOUR ORDINARY COMPACT FLUORESCENT LAMP! Living Spaces by SYLVANIA; your COZY, COMFORTABLE LIGHTING'". Applications Hospitality (hotels, restaurants) Healthcare (hospitals, assisted living) Residential Property management Retail (lighting showrooms, floor displays) CF049 11/08 Application Notes 1 2 3 4. 5. 6. 7. • <1.5 mg of inercury lowest in market • Small form factor - smallest in market • T2 tube diameter - Full spiral technology Wattage 13W, 20W, 23W Do not install on dimming circuits or in outdoor applications Do not use in emergency exit fixtures or lights Do not use on electronic timers, photocells, lighted switches or any other switches that tlo not meet UL20 Sec. 7.6.15 Meets CSA, FCC and UL requirements Use only 120V AC, 60Hz circuit Install and remove lamp from fixture by grasping plastic base, not lamp glass Best performance achieved when operated at 77°F/25°C SEE THE WORLD IN A NEW LIGHT SYLV�N,A � � � � � � � Catalog # � Project � Comments Prepared by _ _ � �j 1 �• � � � Type Date � Average � Item Ordering Bulb Nominal Incandescent Initial Color Rated Energy Number Abbreviation Pkg. Type Wattage Wattage Lumens Temp. CRI Life (hrs.) Star �29972 CFI3EUMICRO/827/LS/RP2 2/box, 6/cs micro-mini 13 60 800 2700K 82 12,000 ✓ 29973 CF20EL/MICRO/827/LS/RP2 2/box, 6/cs micro-mini 20 75 1200 2700K 82 12,000 29974 CF23EUMICRO/827/LSlRP2 2/box, 6/cs micro-mini 23 100 1400 2700K 82 12,000 � � � � � �. � � Compact Fluorescent � DULUX� EL Lumens Life CFI3EUMICRO/LS 800 12,000 � CF20EUMICRO/LS 1200 12,000 CF23EUMICRO/LS 1400 12,000 � 'Energy savings over life of DULUX EL lamp at $0.10/kWh � � � 1 � � (p) �" MOL (in.) CFI3EUMICRO/LS 3.85 � CF20EUMICRO/LS 429 � CF23EUMICRO/LS 4.45 � � � � • � � � �. �° Typical Fluorescent Lamp Mortality �r �oo �<. so � 80 � z 70 > � 6� � � � 50 F- w 40 � U W 30 �j a 20 10 0 � 0 20 40 60 80 100 120 140 PERCENT RATED LIFE � � • • Similar Incandescent 60NW 75A/W 100A/W (B) Diameter (in.) 1.53 2.02 2.02 160 180 200 � z � � � w ¢ � � Z C� ¢ a ioo 95 90 85 80 75 70 65 60 55 Incandescent Lumens Life 850 1000 1170 750 1690 750 (C) Base Width (in.) 1.66 2.14 2.14 Lumen Maintenance Curve Watts Saved 47 56 77 Energy* CFL Life vs. Savings Incandescent $47 10 x $56 13 x $77 13 x ' 1f/ �� _ 50 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10,000 12,000 OPERATING HOURS Living Spaces 2700K o., e o.is o.ia a� o� o.iz aE mo �o o.i U� ar � a 0.08 N � � � 0.06 O Z 0.04 0.02 0 ,�0� p0� Color Rendering Index (CRI) ah° h°° yh° 6�' e`'° �d' ��'' e� WAVELENGTH (nm) Color rendering index (CRI) is a system derivetl from visual experi- ments. It assesses the impact of different light sources on the per- ceived color of objects and surfaces. The first step is to tletermine the color temperature of the light source being rated. Next, each of eight standard color samples is illuminated—first by the light source and then by a light from a black body matched to the same color tempera- ture. If none of the samples changes in color appearance, the light source is given a CRI rating of 100. Any changes in color appearance which do occur result in a lower rating. The CRI tlecreases as the aver- age change in the color appearance of the eight samples increases. Any CRI rating of 80 or above is normally considered high and indicates that the source has gootl color properties. The Color Rendering Index (CRI) is generated by using the 8 sample colors (R1 thru R8), which are then averaged together to produce the rated CRI for the light source. In additional to the 8 colors used in the CRI measurement there are also 6 additional special colors (R9 thru R14) which are not incorporated in the CRI index. As can be seen from the chart below Living Spaces (Retl Line) significantly increases the amount of R9 as compared to standard Compact Fluorescent Lamps (Blue Line). The R9, Strong Red, color protluces richer, warmer, redder color tones. It is this enhancement of the R9 color that makes Living Spaces such a unique product. Truly, Living Spaces is not your ordinary CFL. CRI Test Colors R2 R3 ■ RS R6 R7 R8 - Living Spaces - Standard CFL CF 13 EL / MICRO / 827 / LS / RP2 Compact Wattage: ElecVonic Bulb Type: 8= 82 CRI Living RP= Retail Pack Fluorescent 13 watts Ballast Micro Mini 27 = 2700K Spaces 2 per pack i � � re �ASts usi 11 � rr�as / � j � �! � �W � • � �s � , ° � ��P _ . Instant-On ��- . 111Yill�did�l�C!`i �� 1 �I �. k� �� ,^g', A :� � ft `��4ri �� ., ..� � _ ,,.� CFL Buibs Bom i �`" �� ,��' , -, _--------- � � • ,� SYLViUN/�1 � � LI NG � � � � �� � ���� � �� � � � � � �� � :: � t CFl �, �•. � �� � � � �. � � � � �� �. � � � � SYLVANIA is a registered trademark of OSRAM SYWANIA Inc. � ENERGY STAR is a registered trademark of the U.S. Environmental Protection Agency � - -- �� �� � Lamps shail be a DULUX EL Micro-Mini Twist for Living Spaces having a T2 diameter (13, 20 or 23W). Lamp shall have a correlated color temperature 2700K and a CRI of 82. Lamps shall be designed with enhanced phos- phor techno�ogy for improved color rendition. Average rated lamp life shall be 12,000 hours. Lamp MOL shall not exceed 3.85" (13W), 4.29" (20W) and 4.45" (23W). Lamps shall be TCLP Compliant OSRAM SYWANIA ` National Customer Service and Sales Center 18725 N. Union Street Westfield, IN 46074 USA Industrial Commercial Phone: 1-800-255-5042 Fax: 1-800-255-5043 National Accounts Phone: 1-800-562-4671 Fax: 1-800-562-4674 OEM/Special Markets Phone: 1-800-762-7191 Fax: 1-800-762-7192 Display/Optic Phone: 1-888-677-2627 Fax: 1-800-762-7192 In Canada OSRAM SYLVANIA LTD Headquarters 2001 Drew Road Mississauga, ON L5S 1S4 Industrial Commercial Phone: 1-800-263-2852 Fax: 1-800-667-6772 Special Markets Phone: 1-800-265-2852 Fax: 1-800-667-6772 Visit our website: www.sylvania.com � a �� '�� 0 a A a a a z � � � � 0 � 0 0 .lU�O 4" VERTICAL IC COMPACT P�o�e�t: FLUORESCENT HOUSING Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION 26W COMPACT FLUORESCENT LAMP ICPL Energy Star, Air-Loc� new construction housing • Can be completely covered with insulation • Energy efficient sealed housing does not require separate ALG gasket • Air-Loc housing stops infiltration and exfiltration of air, reducing heating and cooling costs • Easy access ballast • 2 year warranry. PRODUCT SPECIFICATIONS Lamp One 26W triple tube (4-pin) CFL lamp. Socket Fixed mounted socket attaches to top of housing. �" Ballast 120V HPF or NPF Rapid $tart Electronic with endof-life � lamp protection • Optional dimming ballast available • UL listed/CSA certified • Mounted inside housing on a removable J- � box cover for ease of maintenance. Trims Trim selection shown on reverse. Trim gasket provided with � housing. � Labels Energy Star qualified • UL listed for through-branch wiring and damp locations • Meets Washington State Air Tight Requirements, IECC • Complies with FCC Part 18 consumer use � limits • Product mechanically protected against improper use of � lamps • Union made AFL-CIO • UL and C-UL Listed • Complies with California's Title 24 energy code • Trims 1 1, 12, 4101 and � 4102 are wet location approved for covered ceiling applications. Testing All reports are based on published industry procedures; � field performance may differ from laboratory performance. �" Product specifications subject to change without notice. INSTALLATION Real Nail° 3 Bar Hangers Telescoping, patented Real Nail� 3 system permits quick placement of housing anywhere within 24" O.C. joists or suspended ceilings • Integral T-bar notch and clip secures housing in suspended ceiling grid — no accessory clips required • 24" expansion stop allows quick placement of fixture in standard grid spacing • Bars scored in two locations for fast, clean breaking, allowing housing installation in tight applications • Bar hangers may be repositioned 90° • Bars captive to mounting frame • Edge-mounted for extra strength • Captive bugle-headed ring shank nail for quick one-step installation and easy removal with claw hammer for fixture relocation • Quick-Loc slot and oversized locking set screw lock fixture in position • Bar hanger foot contoured to align to bottom of construction joist • Alternate mounting holes included. Juncfion Box Pre-wired junction box provided with (6�'/z" and (1)'/4" knockouts, (4) Non-metallic sheathed cable connectors and ground wire, UL and C-UL Listed for through-branch wiring, maximum (6) No. 12 AWG 90° C branch circuit conductors (3 in, 3 out) • Junction box provided with removable access plate • Knockouts equipped with pryout slots. Mounting Frame 22yauge die-formed galvanized steel mounting frame • Rough-in section (junction box, mounting frame, housing, ballast and bar hangers) fully assembled for ease of installation. Housing Airvloc IC housing, .032" aluminum • Access door for junction box accessibiliy • Removable inner housing is vertically adjustable to accommodate up to a 1" ceiling thickness. REV-3/10 ICPL426E, ICPL426EN � DIMENSIONS � � �, 9' 4 1 /2" CEILING CUTOUT PRODUCT CODES Cafalog Number Inpuf Voltage Lamp Rating (max.) Ballast ICPL426E 120V 26W Triple Tube (4-pin) CFL HPF ICPL426EN 120V 26W Triple Tube (4�in) LFL NPF ICPL426EN-06120 120V 26W Triple Tube (4pin) CFL NPF This produd is Energy Smr qualfied and T24 compliant �2 pand >s to 9 7/8" �kaway ue) • ��. Jura L�N�a+� Gaow EySWWM FI�<trl< � � PHOTOMETRICS � Candlepower Distribution � Test No. 267p140 H2781CAT-78P � Eyeball - 30°Tik �,� �Lamp= 28W Lumens= 1675 �Spacing Criterion= 1.4 � Efficiency= 53.1% � �� �, Cone of Light- 0° Horizontal � Distance to Initial Nadir Beam �.. Illuminated Footcandles Diameter Plane � 5�5� �� - $� 7'0' � 5 10.4' _........ _...... _.....__ , 8'0' 4 11.5' �9'0' . 3 12.9' _ .._-- .._ __..----- 10'0' / 3 74.3' �Beam diameter is to 50 % of maximum foot- candles, rounded to the nearest half-foot. �Footcandle values are initial, apply appropriate light loss factors where necessary. Candlepower Deg. CD 0 254 5 254 15 274 25 268 35 236 45 201 55 160 65 96 75 48 85 15 90 0 Zonal Lumen Summary Zone Lumens % Lamp % Fixture 0-30 238 14.2 26.8 0-40 398 23.8 44.7 0-60 715 42.7 80.3 0-90 890 53.1 100.0 90-180 0 0.0 0.0 0-180 890 53.1 100.0 Cone of Light- 30° Horizontal Distance to Inkial Nadir Beam Illuminated Footcandles Diameter Plane � L W CB 5'5' 10 6.6 7.3 3.2 70•.._ ___. g__.. _. 8.4 9.4 4 g•0' �� 5 9.7 10J � 4.6 g'0' 4 10.9 12 5.2 10'0' ..._ 3 12.1 13A 5.8 Beam diameter is to 50 % of maximum foot- candles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light- 30° Vertical Distance to Initial Nadir Beam Illuminated Footcandles Diameter Plane � L W CB 2'0' 42 2.1 2.9 3.5 3'0' ....- -... 19 3.2 4.3 52 40' ...... 10 4.3 5J 6.9 5'0' 7 5.3 7.2 8.7 6'0' 5 6A 8.6 10.4 Beam diameter is to 50% of maximum foot- candles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. H2781CAT � � Candlepower Distribution �'" Test No. 267p143 ` H2781CAT-404C /'' Specular Reflector �F� �� Lamp= 28W � Lumens= 1675 � Spacing Criterion= 1.9 .2� � Efficiency= 77.6% � � 4HJ � � Candlepower Distribution � Test No. 267p145 H2781CAT-172PS � WhiteTrim w/ �� � Frosted Glass Dome, Wet Location Listed Lamp= 28W � Lumens= 1675 Spacing �"0 � �u Criterion= 1.3 �+ Efficiency= 60.8% � ,c � � • . � � C00%ER Lighting OOP � �. Candlepower Deg. CD 0 320 5 353 15 448 25 507 35 499 45 381 55 257 65 82 75 2 85 1 90 0 Zonal Lumen Summary Zone Lumens % Lamp % Fi�cture 030 386 23.0 29.7 0-40 687 41.0 52.8 0-60 1211 72.3 93.1 0-90 1301 77.6 100.0 90-180 0 0.0 0.0 0-180 1301 77.6 100.0 Candlepower Zonal Lumen Summar Deg. CD 0 264 5 264 15 255 25 243 35 224 45 200 55 174 65 148 75 117 85 86 90 0 Zone Lumens %Lam 0-30 210 12.5 0-40 350 20.9 0-60 659 39.4 0-90 1018 60.8 90-180 0 0.0 0-180 1018 60.8 Cone of Light- 0° Horizontal Dista�ce to Initial Nadir Beam Illuminated Footcandles Diameter Plane ■ T � A 5' 5' � 14 9' .. 7�p•_. .. g � 11.4� .. 8'0' 6 13.1' _ - - g•p• 5 .... .- 14J' . io'o' a ts.a' Beam diameter is to 50% of maximum foot- candles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. / Cone of Light- 0° Horizontal Distance to Initial Nadir Beam % Fi�cture Illuminated Footcandles Diameter 20.6 Plane 34.4 / � 64.7 5�5� _...�._ 9� 7 3' 100.0 7'0' 5 9.3' - --- _ 0.0 8'0' 4 _ __. 10.6' . 100.0 9'0' 3 . 4 71.9' 10'0•..._ __ 3 .... � .. __13.3�-- Beam diameter is to 50% of maximum foot- candles, rounded to the nearest half-foot. Footcandle values are (nitial, apply appropriate light loss factors where necessary. Note: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 168 905.507.4000 FAX 905.568.7049 � �h ��- ZENN T2 � � � � �, �I �1, I� CATALOG NUMBER Photometric Drawing for (1) ZT2-SMT-120 TYPE PROJ ECT C UL US SP CIFICATIONS : i : :> ConStruCtion. Fixture body is constructed of steel. Curved reflector is constructed of aluminum Shielding. For curved reflector, Smooth or Tannenbaum� Ribbed must be specified. DIMENSIONS & DETAILS 3/4' Finish. Fixture body and flange are finished in polyester powdercoat, color RAL 9006. Curved reflector is anodized aluminum. Electrical. Specify 120 or 277 volts. Fixture is provided with integral electronic low voltage transformer. Fixture is UUCUL listed for tlamp locations. iFORMER 3 5/16° � --- i i i i i i i i i i i i i i i i 1'-4 7/8' i i i i i i i i i i i i i i L'__-" Lamping. Single, 50 watt maximum low voltage MR16 halogen lamp with glass integral lens. Lamp not included. Mounting. Fixture may be mounted with lamp facing either up or down. Fixture may be mounted in plaster or drywall up to 1" thick. ADA COMPLIANT. Installation instructions may be found at www.energielighting.com. �Ila���� Energie LLC, 15000 W. 6th Ave, Ste. 202A, Golden, CO 80401 Tel 720.963.8055 Fax 720.963.8044 www.energielighting.com � In an effort to continually improve our products, we reserve the right to change or modify designs and/or materials without prior notice. � n� r� p� All rights reserved. These products may be covered by one or more U.S. or intemational patents or patents pending. 02/10 � � � b� t-� � � TYPE � Z E N N T2 PROJECT c. � .., . � ZT2-SMT � CANDELA DISTRIBUTION LUMINAIRE ,:a � o a5 90 Description: Zenn T2 � "s o 2 2 2 Catalog Number: ZT2-SMT-120 5 3 3 2 � 15 4 4 2 Efficiency:48.8% 25 6 5 1 � 35 g a i Distribution: 14.8% direct, 85.2% indirect �� 45 13 I I i Gc iG 19 1 ZONAL LUMEN SUMMARY COEFFICIENTS OF UTILIZATION LUMINANCE (Candela/sq meter) ANGLE 0-DEG 45-DEG 90-DEG 45 0 595 38 55 0 701 33 65 0 676 30 75 0 713 28 85 0 769 27 ZONAL LUMEN SUMMARY ��II���� Energie LLC, 15000 W. 6th Ave, Ste. 202A, Golden, CO 80401 Tel 720.963.8055 Fax 720.963.8044 www.energielighting.com � In an effort to continually improve our products, we reserve the right to change or modify designs and/or materials without prior notice. � n��� �� All rights reserved. These products may be covered by one or more U.S. or international patents or patents pending. 02/10 � � b� � � � � lfptronics.mm-Energy-SavingLFDLightBulbsandLEDlampsfwAllN�stries 6R/105:55AM � � MyACCnum ShoppicgCar; Checkn�t Call Toll Free ,.a��n by P�� � � ° LEDTRONICS, IN�, L �-aoo-5�9-as�s � �" nr� Furv� of ucNr� C ,� z�� s� 74s3 rou� � ;._, � � Sign In. New User? Sign Up. � HC?MF CONTACT US ta}3G'i=_ .;�'� n42C_ CYUCTS '� t., , '� � t, i iC�N � � i C',t5 .Ir '" ` '.> ^-7 � Home > Product Cateaorv > Tubes. Strios. Strinqs > Stri� & Modular Liahts > Tivoli-Style LED Light Strings, Bright Perimeter Lighting; Durable & Splashproof � LED Light Strings with Tivoli0-Style* LED ��'"��"`� � Light Bulbs � �� „ Check Out � Direct Incandescent Replacement Up to 90%Energy 5avings � Features � Apolications Contact Us � FOR MORE INFORMATION, PLEASE Email This Paqe 4 CLICK A BUTTON BELO i: �' , � \w � • �, ( - � � All Series under this Cate9ory: ►�ia�a9em°ia�'ty� •�. $ystem � LEDS7RING10 Series Light Strings w/ Tivol'r5tyle Bulbs isosoo�:�000 � ��i � ��s �r (;u �lc Translate ` �b �°°d SelectLanguage _-�;� �sautc: � ..- . . { p � .._ .. . . _ - . �� `�'S Gadaels powe2d by „1 __ t09mm —J -i', 0.815 i� �•u.� . Google �, ��-- . [2pJ0) . � � �� � LEDSTRINGIO, 10-meter Length, 100mm LED-to-LED Complete with �EDs � ClearColorless Wire, WaterclearTranspareM LED Base Bectrical-Optiwl Charaeteristics (Ta = 25°C► �j. L' htOut ut . . . . ... Full..-. CLICKTO PART NO. MIN �p� �e�Y � P �x Run �� i��ing OROHt (DESCWP7101� PRICE �, VoMage, V Used, � L� 'iengthlCurrenl. Ertitting ' A�� I� � (rya) w i,,, cd mA Coior �28,,,) � L�STPoNG70-XIVY- � 012V•10M 12Vdc 36Meter ❑Warm AppipUYlf 5138.SOea 1 16.8 W 525 t25° (12VOC,W�White7R) (1.4Artps) (`��) Whi[e � • Other Coiors (Red, Orenge, Yeilow, Green. 81ue7 available for farge quantiryorders � Q?her Va�tage� �ike 74VAC a�'ailable fnr I;�rqe c�uantityorders I � � LEDSTRINGOS Series Light String with Tivoli-Style Bulbs Y� �4��:).k4i � I �es.00J -►{ I� ^E 0�.4 � I . ..p10.2(il httpl/www.ledtronia.com/prodicts/ProductsDetails.aspoe?wP=C622K315�'appliratbns t�. Pagelof4 � . • • � � � � lEDtronics.com-Energy�Savim�LEDLightBulbsandLEDLampsfwAllindustries 6/2/105:55AM �w � � 6 '�i 4,$ s ^1 � l�l�.+{ � � ,.m.{ -'-'� �, \ c)ia.xl� � �� �4 �y Y' � �� _ � � �� ��5 �1e4_?t}�n�r� � , ;'G 701 � „- � �„A LEDSTRING05, 10-meter Length, 50mm lED-to-LED � Complete with LEDs ClearColorless Wire, WaterclearTransparent LED Base � 9edriwl-Optical Cha�aderistics (Ta = 25°C) Pull � CLICKTO PARTNO. MIN �p� �8f9Y LightOutput Iv�xRun L� Viewing OROHt (06CRIPTI01� P�CE �, Voltacje, V' Used, � �� Length/Current, Eniting A�� � (tYP) W Iv,cd MA Cobr (26�) L�5TPoWG05-XIW . , � �ro� 012V-70M y378.00ea 1 12Vdc 33.6W 5.25 18Meter ❑Warm' 125° (12VDC,W.White 6R) (2.8Artps) (��TP�) Whde � � � LED-LP-IOCM Series Light String for Use with Tivoli-Style Bulbs �. � �� _- � � �. , � .. tUChnm - ---Y. �t-- � LED-LP-IOCM, 10-meter Length, 100mm LED-to-LED � String without LEDs ClearColoNess Wire, WaterclearTransparent LED Base �e Bectrical-Optical Characteristics (Ta = 25°C) � hP�t Ful CLICKTO PARf NO. MIN Voltage ,�ergy L'gbtOutput' Max {�n L� Viewing PRICE Used, F�r L� Length/GLrrent; Ertittng A�9� � OROH2 (OE.SCRIPT101� � (bP) yy , I,,, cd MA Cobr �) (20, _ . ------ — - - . �_... ._._... ._--r __.. . _..... . _. __. � L�-LP•10CM-10M-0Ot ' MDTOURT (12VDC,CLEARWFi�NO 534.SOea 2 12Vdc - I -• SArtps -- 3 -- i � L�,NO TRANS {F�}) � � --- . -� -- � LED-LP-5CM Series Light String for Use with Tivoli-Style Bulbs � � � � � f � �f� . . _ __ �,. a.' . � �SDmm �� � �- LED-LP-SCM, 10-meter Length, 50mm LED-to-LED String without LEDs � CiearColorless Wire, WaterclearTransparent LED Base Bectrical-Optical Charaderistics (Ta = 25°C) _ _ _ _ _ . _ _ _ � hput Ful CLICKTO � PARf NO. . MIN ��, VoRage, �ef9Y Light Output Iv�c Run L� Viewing � . PPoCE . �. Used, �r L� '�Length/GLrrent,�Ertittng Angle ORDHt (06CfaPTl01� � -- BUY} (tYP) W I�� cd MA Color � h) 2B, � �� L�LP-SCM-10M•001 ! 2 12Vdc ♦ - SAnps ' .- -- � �ooTOCUrr (izv �n�st�oHSVC � �nio3sa.00ea� --� _ � � �- � PLED500 Series Push-in, 12Vdc, 24VAC Warm White Bulb � ht[pJ/�+�'+w.ledtronics.cem/Products/ProductsDetails.aspoc?YJP=C622K315Mapplirations Page 2 of 4 � • • • � � � � lEDtronics.com-Energy-SavinglEDLightBulbsandLEDlampsiwAlllydustries 6/2/105:55AM � — — o.soo 0o.�e CATHOOE [•1 � '�^� liz.�o� f0e.s�1� � �\�\\ � � 0.244 �1.384. 0.127 (3.101 � ` �� � �,1 • JJI � 1[&20j (09J51 i:'. t.. 1 � t� � 00.201 � 0. j22 (3.101 � 00.19J � _� . 0p.4p5 (05.00j.» — _ 0.275KiJ3) f05.ttj �Ei+l �n, W.000,-0_003 ^ 0330(8.38) `'�� .✓ f01029 +0.00,'0.06� � � "Tivoli�-Style"' Light Bulbs Bectriwl-OpticalCharecteristics (7a=25°C) _ _ � Fuq hput Ener ligM Output Per CLICKTO PARTNO. MIN � Qirrent,. �� L�Emtting Viewing � OR061 (DESCRIPTIOI� PRICE � Vo(tYP)' V, Uswd, ' A Color Angle I,,, cd t2eht _ Y . _. . _ _ ._ _ _ ♦� P��soo-ww- `r �DO7oCAar 012W 53.75ea 25 t2Vdc 0.168W O.Ot5A 525 �Warm �25, (12VDC 7R) ��e � PL�500-7(IW . . . � �ppTpCMT �Z�W ;3.36ea 100 24VAC OJ68 W' 0.013A 5.25 � Warm �zs� (24VAC,W.Wh4e WhAe �� � � PWR-12VCV-3.33A-PF Accessory Power Supply, 0.5 0.25A, Regulated 90-264YAC � to 12VDC 3.3Amp max � -,. - `= Input Voltage Range: 90 to 264VAC � N • M! ��E�'•� DC Output Voltage: 12VDC (3.33A, 40W ) � ��. •.=.-� -- Input Current Max, typ: 115V/O.SA, 230V/0.25A OperationTemp.: -30°C to +60°C Humidity (Non-Condensing): 5% to 90% � 'i� � UL / CUL Listed, CE Listed IPGG Rabed �A PW R-12VCV-3.33A-PF � Power Supply, 0.5 0.25A, Regulated 90-264VAC to 12VDC 3.3Amp max � Bedrical-Optical Characteristics (Ta = 25°C) � CLICKTOORD62 PA��� PRICE MINBUY (D6CRIPTION) • PYYR�I2VCV-3.33A-PF __ ���i (12VDG3.33A,40W,NPUT80-264VAC,PF0.9{F�� S72.00ea 1 - -- � � All specifications and pricing subject to change without notice. � Features: �e • Three Year Warranty � • Light strings can be cut anywhere along the string following common electrical practices � • Sunlight-Visible LED Bulbs with O�er 50,OOOhr Life • High Shock 8 Vibration Resistance LED Bulbs • Wide Angle Visibility � • Mounting Hardware not Included • Spiash-proof � Appacations: � • Tree Lighting • Display Cases �� • Arohitectural and Indirect Accent Decor Lighting • Accent lighting for Lounges, 8ars, Casinos and Clubs �_ 'LEDtronics Inc. Is Not Affiliated with Tiwli LLC � � � http://www.lep[ronics.can/produas/ProduttsDetails.aspn?WP=C622K315+�applications Paqe3of4 � • • - �nl U l� li �r C TM SF Series (2 or 3-light) 0 O O 4-3/8„ �— 11" �- 7/8" End KO ; �, 0 � � SFW Series (3 or 4-light) o �� � � O 4 3/8 � � 0 � Length Wattage 24-7/8" 14T5, 24T5H0, 17T8 36-7/8" 21T5, 39T5H0, 25T8 48-7/8" 28T5, 54T5H0, 32T8 96-7/8" 28T5-8, 54T5H0-8, 32T8-8 Ordering Information Sample: SFW-417T8-UNV-ISN-WH Series � Lamp � Wattage � Voltage � Ballast SF 2 (2 or 3-light, 3 11" width) 4 SFW (3 or 4-light, 16" width) 14T5 UNV 24T5H0 120 17T8 2�� 21 T5 347' 39T5H0 25T8 28T5 54T5H0 32T8 28T5-8 54T5H0-8 32T8-8 T8 Options �.S (Standard) Instant SIaA PS Program Start HEIS High Effiaency Instant Start HEPS High Efficiency Program Start SF and SFW Series Project Name: Type: Date: Catalog #: Description: The Nulite SF and SFW series are a durable low profile surface mounted lensed luminaire. The prismatic acrylic lens softens lamp brightness. These luminaires are ideal for corridors, walk- ways and stairwells. Specifications: Construction: Housing is die formed of 20 gauge cold rolled steel. All metal parts are finished with polyester powder coat paint. Extruded prismatic acrylic lens with injection molded end caps. Optional injection molded, clear prismatic acrylic lens. Spring tensioned clips allow the lens assembly to be hinged from either side. Reflector / Ballast: Ballast cover/pan is formed and finished with high reflectance white paint. Standard electronic, Class P, ballast. Universal (UNV) voltage ballast is from 120 to 277V. Lamping: 2, 3 or 4 lamp cross-section T5, T5H0 or T8. Nominal 8' housing is a tandem lamp configuration. Luminaire can be ordered with lamps, consult factory. Mounting: Surface, individually or continuous rows. Labels: UL / cUL listed. Damp location is optional. Ballast Factor N Normal !s� L �oW �"� High P.S (Standard) N Normal Program Start HEPS' High Efficiency Program start All Lamp Dimming Option; DIM� Dimming $D� Step Dimming Notes: ' 1. Consult factory. 2. Specific voltage must be ordered for this option. Consult factory for nominal 2' units. Color � Options WH White EM2 Emergency Battery Pack (Standard) BK Black � DL Damp Location IN.1 Injection Molded Lens QW Quick Through Wiring for Continuous Row Applications GLR Fusing Specifications and dimensions are subject to change without notification. Specification sheets on our website supersede all other versions. 2010 Rev. B Nulite reserves the right fo bulk package any order. Nulite Lighting 10770 East 51 st Avenue, Denver, CO 80239 Phone 303-287-9646 Fax 303-287-0316 www.nulite-lighting.com � � �(� U� � � � r C TM SF and SFW Series Page 2 � Photometric Curve �. �Cat.# SF-232T8... Initial lamp lumens - 5800 (2 lamps) � Efficiency - 75.6% � iis7 asa • 579 � .. , F � zas • � __ � � � � � �. .� � __ _ � � � Plan view of KOs on back of housing � � 12-7/16" �� � 2" KO �� Nom.2' o, � o � /� ��Typ. Mounting Hole 7r 3-5/8° Typ. �� 18-7/16" � �—� � Nom. 3' o o � o 0 i���. � �Typ. 7/8" KO �` 6" TYP• /� 24-7/i 6" ♦, �— _ _ � � Nom. 4' � o � o° � � � 48-7/16" � �'� Nom. 8' � o � o� � � � � � � � �'" Specifications and dimensions are subject to change without notification. �"" Nulite Lighting 10770 East 51 st Avenue, Denver, CO 80239 Phone 303-287-9646 Fax 303-287-0316 www.nulite-lighting.com � �...) ......� �..b.,.,...b �..... .. .....� ...... ........ � ..b.. . ..� � � You are at � Under Cabinet I CounterAttack � Xenon � � �� .:H S inch Xenon �� I G inch henon NCAX-120-8 NCAX-120-16 �,,,,,,,,,,..�--°� 24 inch Xenon NCAX-120-24 -� 40 inch Xenon NCAX-120-40 �,. .� ��32 Inch Xenon NCAX-120-32 _- -°-- lof1P 1 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 48" Stem Length Mounting of Box by Coatractor Muet be Designed to Hold Full Fulcrum Weight of the FYzture, (Box by Othere). Aluminum Canopy � 1" Dia. Machined Aluminum Stem Machined Aluminum Body Allowa Vertical and Horizontal Adjuatment 5" Dia. 3 1/2" (2) #10-24 s 1" Black Oside O• Heg Socket Head Stainlesa Steel Mounting Screwa ����• 1� � REMOTE TRANSFORMER STYLE . . "C"— Fluah "B" — 90' Cap Style "A" — 45• Over All Length 39 3/4" Maximum z i/4" / 36" Stem Length Power Canopy Option with 75VA Electronic 1 1/2" Transformer Four 3taialeee 3tee1 6 1�2" �� Hutton Hend Canopy Cover D'la. Mounting Screwe for Tnmper Proof Conetruction Geeketed for Wet Loentioa 1[ounting Looldng 0—Ring Compreasion Knuckle '!ti►o 1/2" KO'e for Wiriag v Entrance. l/ill Accept Coaduit or Romez 75VA Electronic 1Ynneformer Coaaectors Two 1/4" Wall Plnte 1[ountinQ Holes 3 1/2' O.C. To 1[ount To Wall or Receseed Outlet Hoz (1[ounting Hardwere Hy Othere) POWER CANOPY DETAIL INTEGRAL TRANSFORMER STYLE EXAI[PLE: SN — 1 — BZP — 9 Seriea: J � Lamp Type. 0 — By Othera 1 — ESX(201V), 12' Spot 2 — BAB(20W), 40' Flood 3 — FRH(35W), 12' Spot 4— FRA(35W). 23• N. Flood 5 — FMW(35W), 40' Flood 15 — EYR 42W , 12' Spot 16 — EYS 42W , 25• N. Flood 17 — EYP 42W , 40• Flood 6 — EXT 50W , 13' Spot 7 — EXZ 50W , 26' N. Flood 8 — E}IN 50W , 40' Flood 9 — FNV 50VY , 60' W. Flood Finiah: I Powdercoat Satin Wrinkle Bronze BZP BZW Black BLP BLW White Gloss WfiP WHW Aluminum SAp — Verde — VER Lens Type: � 9 — Clear (Standard) 10 — Spread 12 — Soft Focus 13 — Rectilinear il — Honeycomb Baffle Can Style: A-45' B-sa C — Fluah Stem Length: Specify Inchea: 18", 24", 30", 38", �42" or �48" (� Not Anailable with "Poxer Canopy Option) Style: C — Straight Mount vy�. PC75-120 — Pov�er Canopy with 75VA PC75-277 — Power Canopy with 75VA (For Use Wifh Ma�rimum � f?� �S SIGN STAR� S' Intertek 8iO3 B-K LIGHTING i � E i F f � 11-09-2010 Inspection Request Reporting Page 5 4:50 pm Vail_ CO - Citv pf Requested Inspect Date Inspection Area Site Address A/P/D Information Activity: 610-0112 Type: A-MF Const Type: Occupancy: Owner: LOPEZ, IVAN Contractor: HOLM CONSTRUCTION INC. Description: REMODEL TOWNHOME Requested Inspection(s) Item: 534 PLAN - FINAL C/O Requestor: Assigned To: BGIBSON Action: Time Exp: Item: 90 BLDG-Final Requestor: Assigned To: JMONDRAGON Action: Time Exp: Wednesday, November 10, 2010 CG 1370 SANDSTONE DR VAtL UNIT 8, EIGER CHALETS Sub Type: AMF Use: IRC � �J ll c-o�,� h�� Phone: 970-390-1315 Status: ISSUED Insp Area: CG Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 02:00 PM Phone: Entered By: MHAEBERLE K Inspection Historv Item: 226 FIRE DEPT. NOTIFICATION Item: 30 BLDG-Framing *" Approved "` 09/01/10 Inspector: Martin Action: AP APPROVED Comment: Item: 50 BLDG�Insulation . ""Approved** _ . _�_._ __�^_, Comment: C3KAY TO DRYWALL ONCE CORRECTIONS ARE COMPLETE Item: 60 BLDG-Sheetrock Nail "* Approved "` 09/14/10 Inspector: mdenney Action: AP APPROVED Comment: Item: 70 BLDG-Misc. 06/22/10 Inspector: CG Action: NO NOTIFIED Comment: REVIEWED PARTY WALL WITH CONTRACTOR Item: 90 BLDG-Final Item: 534 PLAN - FINAL C/O C� �� �o �� � C � ONDITIONS REPT131 Run Id: 12177