Loading...
HomeMy WebLinkAboutA10-0016TOWN OF VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 VAIL FIRE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 1980 S FRONTAGE RD E VAIL Location.....: 1661 SUNBURST DR. Parcel No...: 210109200002 Project No OWNER TOWN OF VAIL 05/05/2010 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL CO 81657 APPLICANT BEST ELECTRIC, THE P.O. BOX 273 EAGLE CO 81631 License: 640 -S CONTRACTOR BEST ELECTRIC, THE P.O. BOX 273 EAGLE CO 81631 License: 640 -S Permit # Status ... . Applied..: Issued . . . Expires . .: A 10 -0016 ISSUED 05/05/2010 05/17/2010 11/13/2010 05/05/2010 Phone: 970 - 328 -1610 05/05/2010 Phone: 970 - 328 -1610 Desciption: STARTER SHACK ALARM - ONE ON ONE CHANGE OUT WITH ADDED NOTIFICATION Valuation: $3,500.00 s► i# fkfkitw #wkf► * * # ## * # *► # * it * #i#► iii ►►#► # # # # # # # # # # # # # #w # # # # # ## ### FEE SUMMARY kksk####►# w## 4##►*#►# ii# k# i#* # #► # # # #s#► #i #kkiifw # # # # # # ## # ## ** ttt# kt### t# 4## i## ii4*# i#***##►#►# k### ktt# t##* w# it#*###*##*### t#*# i# f#*#►►*►#►* i## t#► t# t# tt###### fwt####*##*###*# # ► # ► *R # # # *t # ## #t *#s * # * # # * *► f # ► DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HO Electrical-- - - ---> $0.00 Total Calculated Fees —> $419.25 DRBFee- - - - - -> $0.00 Additional Fees--- -----> ($419.25) Investigation - -> $0.00 Total Permit Fee ---- -> $0.00 Will Call---- --- - -> $0.00 Payments------------ ---- -> $0.00 TOTAL FEES - -> $419.25 BALANCE DUE ----> $0.00 tiifitikis# Rif# wfw#►*►## it►# k►# it► ififw► ktf### i# w#f#####►###►##►### tii# f# tkt# i►#►► kfiii# ff###►##►►#► i#►## k# tf►► t►# ►i►►k► # # #i #f # #►fww #ww # # i # #► #i #► Approvals: Item: 05600 FIRE DEPARTMENT 05/11/2010 mcgee Action: AP ## kti# t# fwwfi► w*## 4►# flit► 4► 4►### fif# i# f#► k## w# w# if#►# t#►#►#►# i# t# i►►##►#►## kf►#► f►► k######## wf####►*►**►►#►##►# i ► #► #► #► #k #k #►i #►#i # # #i # #ki #f # # CONDITIONS OF APPROVAL ** ttt# kt### t# 4## i## ii4*# i#***##►#►# k### ktt# t##* w# it#*###*##*### t#*# i# f#*#►►*►#►* i## t#► t# t# tt###### fwt####*##*###*# # ► # ► *R # # # *t # ## #t *#s * # * # # * *► f # ► DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HO SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER � A SS Department o ommunt y eve opmen f 75 South Frontage R ad Vail, Colorado ; . iTel. 97A�47 N De o men e - - "`�° onded RT-1Q ARM PERMIT AWrove as SU� rc I a Fire Alarm shop drawings are required at the time of application ra5i� information l isted on the 2nd page of this form. Application will �Y� -� nat hP arcP[Zted Without this information `itle:�C )ate: Project Street Address: 1�I- ISIS htV__��+ f r_- Vdi (Number) (Street) (Suite #) /" Building /Complex Name: (-3 C, Yt" l 6 U./ `, 7",-( , r e✓ 5 Lh It /- I/ Contractor Information: i L Company: aLs _ l lelc ( L P Company Address: I . 0 1 o, City: Stater Zip: Contact Name: �Ql 11s Contact Phone: 9 1 E -Mail - 44\ri ,- )E st vat ( - ILL° -t / I Vont4 ctor it Contractor Registration No.: Signature (required) Property Information Parcel #: 1j l a d ko \ nC1 2- — VZ, (For parcel c ontact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglec / / Tenant Name: V �� (K Lft' aii J ( � JI &�.G (W A) L A) I o Owner Name: wiI 6k & ( ( Office Use: (J r / Project #: 1 — � — o Building Permit #: Alarm Permit #: Lot #: Block # Subdivision: Detailed Description of Work: nAC ©�� I, eth (use additional sheet if necessary) Does a Fire Alarm Exist? Yes (x) No( ) Does a Sprinkler System Exist? Yes( ) No 06 Work Class: I New ( ) Addition ( ) Remodel ( ) Repair ( ) Retro -Fit ()() Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial �k) Restaurant ( ) Other ( ) Date Received: Complete Valuation for Fire Alarm Permit: qV Fire Alarm $: Do MAY 0 4 2010 Lc, TOWN OF VAIL 29- May -09 Battery calculations A list of specific device model numbers Equipment cut sheets of each type of device The number of each type of device Information indicating the specific zones Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the following: A Colorado Registered Engineer's stamp t Device locations on reflected ceiling plans Reflected Ceiling Plans (RCP) Typical device wiring diagrams Battery calculations Circuit diagrams Point to point wiring diagram Wiring type, size and number of conductors The source of AC power circuits Fire alarm panel locations Knox Box location Fire Department Process For Commercial & Residential Fire Alarm Systems Information indicating monitoring method and monitoring agency Information regarding property managers and contact numbers Owner's primary residence location and contact numbers Instructions for fire alarm system operations and any pertinent code numbers for proper opera- tions This check list has been provided to ensure that our review process may be handled in a timely manner. I have read and understand the above listed submittal requirements: Project/Street Address: JL Contractor Signature: Date Signed: U 29- May -09 Fire Department Guidelines For Preventing Non - Emergency Fire Alarms In order to prevent a non - emergency response from the Vail Fire Department Suppression crews to the con- struction location you may be working on, we ask that you perform the following tasks: S� Determine what kind of fire alarm system exists within the structure you are working in with the owner or the manager of the property involved or by contact- ing the Vail Fire Department. Determine with the owner or manager of the property, which alarm company services the system for them Become familiar with the different components that are associated with the fire alarm system and how they operate before the DEMO begins. Never paint a smoke detector, thermal detector, or any other component of the fire alarm system and never paint a sprinkler head. For larger projects, please contact the Vail Fire Department so that we can work with you in determining what needs to be done to alter or "Zone Out" spe- cific areas of the alarm system for the structure. Please contact the Vail Fire Department at 479 -2252. I have read and understand the above listed submittal requirements: Project/Street Address: Contractor Signature: Date Signed: 29- May -09 Fire Department Guidelines Pre -Plan Information Sheet BUILDING INFORMATION: Building Name: Street Address & Phone #: Knox Box Location: KA Alarm Panel Location: h�r� Alarm Silence & Rest Codes: aSQS RPS': Names & Phone Numbers (Work & Home) Owner: Property Manager: Property Maintenance Mgr: Alarm Service Company: BUILDING UTILITIES: Gas: Main Location: Other Locations: Electric: Main Location: Other Locations: Water: Main Valve Location: Main Fire Valve Location: Secondary Fire Valve LOG: S �+ 29- May -09 U � Q LO Cn oO w O 00 R9 Q J —O � CO � w � 00 R9 fy o Q C--,% > —O � O � U nnn LL m J z 0 D (D U) J � ® awls aiu ®W H LL O 36' 10" - o O = w Z w H � cn Q W W = n Ow O z C) O W W Y W � ow o s w z a_ J W 0 Z W J Q U) 0 0 Z C 00 R9 N o Q C--,% > —O N o LL I 0 _ X ( =U p nnn mO 3:J co O m H D Q WA m H U) Q 0 U C.0 CO =Cfl 00 L1J N z 0� N —O co 0 _ X ( =U p m mO 3:J co o M< W ti � �. IntelliKnight® Model 5700 Single Loop Addressable im Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control /communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 800 - 328 -0103 or in Connecticut, call 203 -484 -7161. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial /parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports Hochiki or SK devices. 5700 also features a powerful built -in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built -in support for up to 50 Hochiki devices or 50 SK detectors and 50 SK modules. • Up to 125 zones and 125 output groups • Uses standard wire —no shielded or twisted pair required • Built -in digital communicator. • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Distributed, intelligent power • Drift compensation • 13 pre - programmed output cadences (including ANSI -3.41) and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built -in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances • Built -in annunciator with 80- character LCD display • RS -485 bus provides communication to system accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Improvements in SKSS deliver five times faster upload /downloads • Built -in RS -232 interface for programming via PC • Built -in Form C trouble relay rated at 2.5A at 27.4 VDC • Two built -in Form C programmable relays rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Installation The 5700 is a surface mount FACP. Compatibility The 5700 SLC supports multiple device types of the same protocol: • Hochiki • SK You cannot mix Hochiki and SK devices on a FACP. However, any combination of addressable devices of the same protocol can be used on the 5700. 31 SILENT KNIGHT by Honey ea Model 5700 Model 5700 Fire Alarm Control Panel ]c f'YT,Z'�I Specifications Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power - limited Standby Current: 200 mA Alarm Current: 325 mA Notification /Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power - limited Battery Charging Capacity: 7.0 -35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power - limited notification appliance circuit outputs. 5880 LED /10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865 -3 and 5865 -4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865 -4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. Approvals 5824 Serial /Parallel Printer NFPA 13, NFPA 15, NFPA 16, NFPA 70, & Interface Module Provides one parallel and one RS -232 serial Miscellaneous Accessories 5660 Silent Knight Software Suite User - friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End -user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505 -DTS -K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505- DUCTR. Hochiki and SK Devices See the specification sheets listed below for a complete listing of the Hochiki and SK devices. 53624 Hochiki Devices Specification Sheet NFPA 72: Central Station; Remote Signalling; port for connecting a printer to 5808. Use to Local Protective Signalling Systems; Auxiliary print a real -time log of system events, detector 53623 SK Protocol Devices Specification Protected Premises Unit; & Water Deluge status reports, and event history. Interfaces Sheet Releasing Service. Suitable for automatic, with building control system. manual, waterflow, sprinkler supervisory (DACT non - coded) signalling services. Other Approvals: UL Listed; CSFM 7170 -0559: 144; MEA 429 -92 -E Vol. XVI. SILENT This document is not intended to be used for installation purposes. We try to keep our product MADE IN AMERICA information up -to -date and accurate. We cannot cover all specific applications or anticipate all i3l KNIGHT requirements. All specifications are subject to change without notice. For more information, PIN 350392 Rev. F contact Silent Knight 12 Clintonville Road, Northford, CT 06472 -1610 ECN 09 -520 09/09 by Hon"Wlr Phone: (800) 328 -0103 or (203) 484 -7161, Fax: (203) 484 -7118. www.silentknight.com IntelliKnight & JumpStart are Registered Trademarks of Silent Knight © 2009 Honeywell International Inc. Flexput is a Trademark of Silent Knight vu�y mo-a � I I 1 i I I Av I }�7��MNR1 �✓M I 5700 5496 CJGOJC"t �}Ip TDi -hC7 71911+Mk tlNFYN ]c f'YT,Z'�I Specifications Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power - limited Standby Current: 200 mA Alarm Current: 325 mA Notification /Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power - limited Battery Charging Capacity: 7.0 -35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power - limited notification appliance circuit outputs. 5880 LED /10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865 -3 and 5865 -4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865 -4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. Approvals 5824 Serial /Parallel Printer NFPA 13, NFPA 15, NFPA 16, NFPA 70, & Interface Module Provides one parallel and one RS -232 serial Miscellaneous Accessories 5660 Silent Knight Software Suite User - friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End -user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505 -DTS -K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505- DUCTR. Hochiki and SK Devices See the specification sheets listed below for a complete listing of the Hochiki and SK devices. 53624 Hochiki Devices Specification Sheet NFPA 72: Central Station; Remote Signalling; port for connecting a printer to 5808. Use to Local Protective Signalling Systems; Auxiliary print a real -time log of system events, detector 53623 SK Protocol Devices Specification Protected Premises Unit; & Water Deluge status reports, and event history. Interfaces Sheet Releasing Service. Suitable for automatic, with building control system. manual, waterflow, sprinkler supervisory (DACT non - coded) signalling services. Other Approvals: UL Listed; CSFM 7170 -0559: 144; MEA 429 -92 -E Vol. XVI. SILENT This document is not intended to be used for installation purposes. We try to keep our product MADE IN AMERICA information up -to -date and accurate. We cannot cover all specific applications or anticipate all i3l KNIGHT requirements. All specifications are subject to change without notice. For more information, PIN 350392 Rev. F contact Silent Knight 12 Clintonville Road, Northford, CT 06472 -1610 ECN 09 -520 09/09 by Hon"Wlr Phone: (800) 328 -0103 or (203) 484 -7161, Fax: (203) 484 -7118. www.silentknight.com IntelliKnight & JumpStart are Registered Trademarks of Silent Knight © 2009 Honeywell International Inc. Flexput is a Trademark of Silent Knight vu�y mo-a � I I 1 i I I Av I }�7��MNR1 �✓M I 5700 5496 SILENT KNIGHT SD500- PS /SD500 -PSDA Installation Instruction The SD500- PS/PSDA is an addressable fire pullstation. The SD500- PS/PSDA is a normally open initiating point compatible with Silent Knight Addressable control panels. The SD500- PS /PSDA is designed for indoor use in non- explosive environments. Used to activate a non- coded alarm instantly. An on -board status LED is visible from the front of the pullstation. The LED flashes to indicate proper communication with the FACP (approximately every 30 seconds). Specifications Parameter Rating Max. Line resistance One device in alarm Max. Alarm 23mA. 46 mA for 5 mA for each additional device in Current two devices in alarm. alarm. Max. Voltage 33 V 0 to 49° C Operating Temperature (32° to 120° F) Height 5 -1/8" Dimensions Width 3- 1/16" Mounting Depth 1.5" Operation To activate the fire pull station: 1. Grab the top of the pull station where it is labeled "PULL ". 2. Pull the cover plate out and down. To reset the pull station: 1. Insert key into the lock. 2. Turn the key clockwise. 3. Close the cover plate. 4. Turn the key counter clockwise. Wiring to the SD500 -PS /PSDA Supervised Power Limited r r` _- ~• __2 F11Mr. l A ios� nt . w�wo ■s - Figure 1: Fire Pull Station Wiring Wire the SD500 -PS as shown in Figure 1. FACP Mounting the SD500 -PS /PSDA The pullstation mounts to a standard single gang electrical switch box or a surface mount back box P/N PS -SMBB (sold separately). See Figure 2. P/N 151177 Model SD505 -6SB Installation Instructions Single Gang PS -SMBB Electrical \ -� Switch Box Mounting Holes'„ �w \ 1 - t ... �'. r t \ � 1 IJ To meet ADA requirements the .__..� - pull station must be mounted 48 " ----- ' from the floor for wheelchair forward - - -. access and no more than 54" from the floor for wheelchair side access - -- Figure 2: Mounting the Fire Pull Station Installing The SD500 -LK The SD500 -LK is used to convert the SD500 -PS (single action pullstation) to a SD500 -PSDA (Dual action pullstation. Refer to Figure 3 to install the SD500 -LK Dual Action Conversion Kit. Figure 3: SD500 -LK Installation 3@ SILENT KNIGHT 7550 Meridian Circle Maple Grove, MN 55369 -4927 763 - 493 -6455 800 - 328 -0103 Fax: 763-493-6475 © 2002 Silent Knight P/N 151177 Rev. C, 05/02 http://www.silentknight.com 2 P/N 151177 Addressable Heat Detector im IntelliKnight® addressable heat detectors combine accurate heat detection with pin -point location ID. An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505 -AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD5O5 -MS It the temperature exceeas the trip Addressable Heat Detector point (programmed at the panel), an alarm occurs. The status LED The SD505 -AHS is a heat detector suited to virtually any commercial setting. The SD505 -AHS is an absolute temperature device. This means that it responds in alarm if the temperature goes above the trip point (programmed at the panel). lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. -. The SD505 -AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505 -AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the IntelliKnight panel. • Low profile, 2 inches, including base • Absolute temperature device • Simple and reliable addressing • Uses digital communication protocol • The SD505 -AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. • CFSM listed • MEA listed • FM approved SILENT KNIGHT SD505 -AHS Heat Detector Specifications Operating Voltage: 17 to 41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135 °F to 150 °F (57 °C TO 65 °C) Ambient Temperature: 32 °F to 100 °F (0 °C to 37 °C) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70' between sensors on smooth ceilings. Compatible Bases: SD505 -6AB (Sold Separately) (6" Base) SD5054AB (4" Base) Model SD505 -AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505 -AHS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505 -APS Photoelectric Smoke Detector, or SD505 -AIS Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF /transient suppression techniques shall be employed to minimize false alarm potential. Diameter = 5- 15/16" Q f Height = 2 inches, including base Model SD505 -AHS Detector Head (Front View) SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 800 -446 -6444 or in Minnesota 763 - 493 -6435 FAX: 763-493-6475 World Wide Web: http: / /www.silentknight.com Diameter = 3- 15/16" O MADE IN AMERICA FORM# 350229, Rev. 01/01 Copyright © 2001 Silent Knight Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SDSOS -APS Analog / Addressable Photoelectric Type Smoke Detector The SD505 -APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505 -APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built -in fire test feature • Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. • Vandal- resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved * . ` Him SD505 -AM Smoke Detector Specifications Operating Voltage: 17 -41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32 °F to 100 °F (0 °C to 50 °C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505 -6AB (Sold Separately) (6" Base) SD505 -4AB (4" Base) SILENT KNIGHT Model SD505 -APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5- 15/16" i /�9CENT / IQVIQi7' Model SD5054M Detector Base (front view) Diameter = 3- 15/16" WIND o 10 j Model SD505 -APS Detector Head (front view) Height = 2 inches, including base SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 800 -446 -6444 or in Minnesota 763 - 493 -6435 FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight.com MADE IN AMERICA FORM# 350225, Rev. 12/01 Copyright C 2001 Silent Knight SYSTEM �4 SENSOR Selectable- Output Horns, Strobes, and Horn Strobes SpectrAlert" Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features • Plug -in design with minimal intrusion into the back box •Tamper- resistant construction • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Field- selectable candela settings on wall and ceiling units: 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall and ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with existing SpectrAlert products • Compatible with MDL sync module Agency Listings SIGNALING 0 U L F M LISTED APPROVED 54011 (chimes, horrSL'obes, horns) 3G�3572 5551 Z (strobes) crime strobes) PIP The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SPECTRAJW-i r o m S e t e S e n 0 MEA approved 7125 - 1653:186( indoor strobes) 7125 - 1653:188 (horn strobes, MEMS205 -E crime strobes) 7135- 1653:189 (horns, chimes) PIP The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SPECTRAJW-i r o m S e t e S e n SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 1 back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95, 110, 115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobes entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4'1/,8 x 4 11 /16 x 2 -inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32'F to 120 °F (0 °C to 49°C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC /FWR or regulated 24 DC/FWR Operating Voltage Rangez 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6'L x 4.7 - W x 2.5'D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6 - L x 4.7 - W x 1.3' D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 L x 5.0' W x 2.2' D (151 mm L x 128 mm W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1 diameter x 2.2' high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS, TRW -HS) 5.7 x 42 x 0.35'D (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC- HS,TRCW -HS) 6.9 diameter x 0.35' high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05 -0395007 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 Candela Range 150 177 NA NA 228 207 8 -17.5 Volts 16 -33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non - temporal High 57 56 69 75 Non - temporal Medium 42 50 60 69 Non - temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 NA NA 246 220 Coded NA NA 281 251 Low 40 46 52 50 185 UL Max. Current Draw (mA NA NA RMS), 2-Wire Horn Strobe, 286_______258 Standard Candela Range (115-115 cd) 84 88 88 99 DC Input 8 -17.5 Volts 15 15/75 16 -33 Volts 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 Temporal High 136 155 86 88 96 97 112 168 Low 190 73 210 76 218 Temporal Medium 129 152 4 78 High 88 103 160 88 184 92 202 100 206 Temporal Low 129 151 78 76 85 86 101 160 98 184 Non - Temporal 194 75 201 Non - Temporal High 142 161 84 103 92 112 126 181 82 203 88 221 93 229 Non - Temporal Medium 134 155 Coded 85 78 95 110 166 90 189 97 208 216 Non - Temporal Low UL Max. Current Draw (mA 132 RMS), 2-Wire 154 Horn Strobe, High 80 Candela 90 Range 105 (1135-185 cd) 161 184 202 211 DC Input 16 -33 Volts 135 150 177 185 FWR Input 16 -33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non - Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non - Temporal Medium 219 232 262 267 Non - Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output 8 -17.5 16 -33 Switch Volts Volts Position Sound Pattern dB DC FWR DC FWR 24 -Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non - Temporal High 82 82 88 88 93 92 100 100 5 Non - Temporal Medium 78 78 85 85 90 90 98 98 6 Non - Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 8 Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn strobe. A05 -0395 -007 rAlert Advance Dimensions Ceiling -mount horn strobes 7.t I- 2.25-1 5.05` j �2.23t DI a. P IP o 0 Q P� 00 5.98" 0 LJJ Q Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2R *' 2 -Wire Horn Strobe, Standard c&, Red P2RH* 2 -Wire Horn Strobe, High cd, Red P2W* 2 -Wire Horn Strobe, Standard cd, White P2WH* 2 -Wire Horn Strobe, High cd, White P4R* 4 -Wire Horn Strobe, Standard cd, Red P4RH 4 -Wire Horn Strobe, High cd, Red P4W 4 -Wire Horn Strobe, Standard cd, White Wall Strobes SR ' Strobe, Standard cd, Red SRH *t Strobe, High cd, Red SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn Strobes PC2R* 2 -Wire Horn Strobe, Standard cd, Red PC2RH 2 -Wire Horn Strobe, High cd, Red PC2W*t 2 -Wire Horn Strobe, Standard cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW* Strobe, Standard cd, White SCWH Strobe, High cd, White Horns HR Horn, Red HW Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW -2 Back Box Skirt, Wall, White BBSC -2 Back Box Skirt, Ceiling, Red BBSCW -2 Back Box Skirt, Ceiling, White TR -HS Trim Ring, Wall, Red TRW -HS Trim Ring, Wall White TRC -HS Trim Ring, Ceiling, Red TRCW -HS Trim Ring, Ceiling, White PC2WH* 2 -Wire Horn Strobe, Hiqh cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: *Add " -P "to model number for plain housing (no'FIRE'marking on cover), e.g., P2R -P. t Add " -SP'to model number for "FUEGO'marking on cover, e.g., P2R -SP. *'Standard cd'refers to strobes that include 15,15/75,30,75,95, 1 IQ and 115 candela settings. "High cd'refers to strobes that include 135,150,177, and 185 candela settings. 02009 ,ar System Sensor. S YSTEM r7 / EM 3825 Ohio Avenue • St. Charles, IL 60174 rroau< cso�tonssudearoa k9e[non-Msrcsyst­­on,ra SENSOR A05 5 -0395- 0 • - p # 2132 OR Phone :800- SENSOR2•Fax: 630- 377 -6495 ° °� podu in `- 039507.402132ormndaa:ee