HomeMy WebLinkAboutM10-0065 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ,. �w�o�vnQ;• Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.4792149 MECHANICAL PERMIT Permit #: M10-0065 ACOM Project #: PRJ10-0177 Job Address: 174 E GORE CREEK DR VAIL Status. . . : ISSUED Location.....: SERVER ROOM, LODGE AT VAIL Applied. . : 05/12/2010 Parcel No...: 210108281001 Issued. . . 05/19/2010 Expires . .: 11/15/2010 OWNER LODGE PROPERTIES INC 05/12/2010 Phone:81657 IN CARE OF C/O FIXED ASSETS DEPT 390 INTERLOCKEN CRESCENT STE 1000 BROOMFIELD CO 80021 APPLICANT TOLIN MECHANICAL SYSTEMS COM 05/12/2010 Phone:303-455-2825 12005 E 45TH AVE DENVER CO 80239 License:221-M CONTRACTOR TOLIN MECHANICAL SYSTEMS COM 05/12/2010 Phone: 303-455-2825 12005 E 45TH AVE DENVER CO 80239 License:221-M Desciption: COMMON ELEMENT: INSTALL MINI SPLIT AIR CONDITIONING TO SERVER ROOM IN BASEMENT Valuation: $10,000.00 «........«.......«............................................,....,"�............FEE SUMMARY..............«.....»......,�....�.........*......�......�.......«..................... Mechanical Permit Fee---> $200.00 Will Call------------> $4.00 Total Calculated Fees---> $254.00 Plan Check------------------> $50.00 Use Tax Fee------> $0.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> 5254.00 Total Calculated Fees--> $254.00 Payments---------------> 5254.00 BALANCE DUE---------> 50.00 w�eewww�r�wxwrxww,ew�www�rawtaawwrr�r+rwww��rwwxw.vrtwwwrnewwwwtrr,rww�wqiwx►tnwww�eav:wtwwxww,rtirnw�rwwrer,rwt,v.rwwt,tw�w�:�,t►:*wt.,'�����.�***+*r,t►:wir�wwff�►��*:,�+'*►,t:Mi*�i►►f�ir+�sr:,t��t:w���►� APPROVALS Item:05100 BUILDING DEPARTMENT 05/19/2010 cg Action:AP ♦►ww��of�*+r�tr�r:t�rxx*�wr��.se:s.ive�t+m�i*i+rtr+��►wt*�*�rt�i►:n�w*►w�w+wwrwe,t►�►yv r�tw+ert+nwwrrewwwrwrertrrt,rxrw�w+rWr,�tt�xw,rw�,Ktw:��v►++ximw+.ri�vewntww.r,t�r�,et+t+�rwtw�xx�tr�+,r►xwr►r+�www.erwwrr CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond:42 (BLDG 2009)CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 1nlff iiN�f�lkfff�tRkM}�HrfMlrf�l+lH*1�HtR►##**1rfr�flr�!#R�tR+��tMR#RRiMO**kM�hH��!#RR►RRN*R*►+hFrtf�Ff'4+hl�ldtMf�l�ll�InlM#1tR�R+RQMM�tk�RkYnH'f#iR�tkRMR*tk W�e+4RHRfr�ttr4k�MrtrRVMt�tt+4+R#M+RRtRYrA+R�etR#f�!#M*�RtNeft# DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4 PM. 4 U i natur r or Con ctor Dat Name m ec h ca n ica I_pe rm it_041908 M10-0065: Entries for Item:390 - MECH-Final 09:48 12/04/2013 Action Comments By Date Unique_ Ke AP See Shanes inspection Martin 11/26/2013 A000164 677 Total Rows: 1 Page 1 ***�*******�*s*�M�*�**#****rt****�*********�w*rt***�s*******s*�**�a*�*s**t*esss�*sM**w*s**�*** TOWN OF VAIL, COLORADO Statement *�e**s*�ss*a*s�sa*rt*s*****�ss�s#*s***s**�**�s****ss*********s**ss�*�***�******+r*s*t**�*�**f*rt Statement Number: R10000a505 Amount: $254.00 OS/19/201001:57 PM Payment Method:Credit Crd Init: LC Notation: CREDIT CARD FROM MIRE CLEMENT, TOLIN MECH ----------------------------------------------------------------------------- Permit No: M10-0065 Type: MECHANICAL PERMIT Parcel No: 2101-OB2-8100-1 Site Address: 174 8 GORE CREEK DR VAIL Location: SERVER ROOM, LODGE AT VAIL Total Fees: $254.00 This Payment: $254.00 Total ALL Pmts: $254.00 Balance: $0.00 *sr*K***�***�**s*+�*M**#**ss#*t****rtM***rt�#*s**s*****�r�***M**�rs+***sy���#*****s***s*******s* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- --------------_---------------- ___--------- MP 00100003111100 MECHANICAL PERMIT FEES 200.00 PF 00100003112300 PLAN CHECK FEES 50.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- ' � � "� ' '� '� ° ` ' Departrnent,of�ommurtity D�velopinen � � �f�� ��� �.� ` ' � '�5 South Frantage � ` ,��', .� �, �"'% 'a.� �q� �� .��.- �y` '. .�� �a �.1°� � `..�,,,, �y��,�•.d, r �, �1 .II..'.k '��i , �: a��#� � �'< � t��� . Ya��.�.i� Vr� '�` . `�S's�� ��� `b.' . , 'p� s.`a,E'ys <��� � . . � a r �,. .. e . L. �a . � . � .. ,� �� � W . ` �,;� ;�� µ�, �. ��;� t �� �' � �t,y�� `�' �` . � � �� �� , .��• a' .» ir' �� '�' 3� � . < �'� ^ t_ _, � . . W i , .� , �. _ e� . .., � ; ,.��- � � rt _ - �.�, . . ,.�,�, _ . �,. �. • : MECHANICAL PERMIT � Boiler / Furnace &Fireplace Applications MUST include: (,e���1� ❑ Complete Mecharncal Room Floor Plan with Dimensions ❑ Boiler size&e�ciency �Q� ❑ Combustion Air Duct Size and Location ❑ Equipment Cut Sheets for Fireplaces/Log Sets� � � ❑ Flue detail or Vent size, location&termination (Manufacturer's info showing make, model &appro I sting) ��l ❑ Gas Piping layout including development length calculations Office Use: 2 �( ❑ Heat Loss Calculations Project#: � �� — Q �� � \ \ _ _ __ __ ��I� IC�a � Project Street Address: Building Permit#: �� ��� �o�� (�� � � � Mechanical Permit#: M� d � G��� (Number) (Street) (Suite#) /�� Lot#!'�w Block#GlC Subdivision: v����- I ' Building/Complex Name: ���� �•� � t ��_ I ` Define Scope and Location of Work: �� d ,�" v Contractor Inform ti n: ,Q � • /"� Company: ��n �'►PL �u,,.v. � ��1 � SCrva � .�o•� � � �n Company Address: $73 /��-�.•�s ,,�-�•c �� _ b-s e �---c...-� .. ,/1�: f�v b�, I.,�' City: 7�•�VC�'�,�1..� State: Zi l�r � p• (use additional sheet if necessary) Contact Name: ���<-�-J'J• R �� S 4 3 g�i �I ��_c�q 3 ° Gas Piping Included Contact Phone: ❑ Gas Piping by Others E-Mail ❑ Wood to Gas Fireplace Conversion ... , _. _ ,._ _ Town of Vail Contractor Registration No.: �21 '� Boiler Location: Interior( ) Exterior( ) Other( ) X /',��- D _. . . �., , . . , . . _ . :Number of Existing Fireplaces: Contractor Signature(required) __. , , .. ,._,.. .. , ,: : : ,,, :,Gas Appliances Gas Logs Wood/Pellet Property Information ..,, ... .. . ., . __, . . . � Parcel#: �' ���$ 2 �Q(�1 `Number of Proposed Fireplaces: (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or 'Gas Appliances Gas Logs Wood/Pellet . visit www.eaglecounty.us/patie) _ _ Type of Building: Tenant Name: (Commercial Properties) Single-Family( ) Duplex( ) Multi-Family( ) Commercial(y) Owner Name: �^• �P�"''P��� �s Restaurant( ) Other( ) Date Received: ,S�� Complete Valuation for Mechanical Per it: (including fireplaces) 2 � �/7 (� D LS V � O �"! l.� Mechanical$: � O0� MAY � � 2010 TQWN t��' V�IL C:\cdev\forms\permits\bu il ding\mechanical�ermit_010110 �:� Town of Vail . o_, _o____ � �ppY ; � ICE OFF � : . : � ,t: - ___ . � . . � o il � �J�! r!� i � ,� I ;' d. o a � _ � '�� '� i � �Jy�!; ,� . a o , � . ; � � � � — -- � a __...._..... . _ . . . r�t�_ �r Ma i miu...,+ yM1�r�' _ . --r q"pTir—_� , ..I . -_� ° ° �� -----y'�-��.._ r---------- u+we �� -- — I------- -- _ . . . psile'. 'J.. . ...—' ' .. �. �� . . . . . . . . ,. ... , �' � y� .. _,. . . . 0 L�.. --..:.-'--'--- ' --_'_� tMi��ieV.MM:NMt'�p MyAf' . �. .::. . '.� �. , . . ' . - . KFi ' ._'___ _�� ' . ..' � ° ° �,! ��Po�Af.%D � ��� �c-F � e,-, � �„NnkP• 'p,,ur���^f. ° ° .�o �' �(,I. i�i � : �poY�'I .ti 0 0 �� �,� : A � � 1 , � � �t A.��: 1 a _ . _ ���a � � 1r. ��-_ , �S N�'}t: °Pf'n ' • . � � .. . . . . . .. �� . . , '��__'.'__.__v . . ...JUI i7 191t 1 \\ J 2 OI1IOl.No.8���7 �T�' . . ''�4r° \ .;j � ==-� _ _ � . . � . � . � � . . � � � � . � . Owq,Nn. ��� � ���� ;w�+_., . , � .� ,�_" v�._'Cit�l _�""..';'.r�—.� �' � w' � J�r y '�✓ 4.. 'd ,� � �a2. i-� � ?� .� t � -�� ar.ew++i.i�.lA+ � � � � <�a . . . . ' . � �..` ' .i�'� .. � .r' � . .y.� �. 1 � � . ,� �� �T�w, LL � I . . . t�i'lo � � . � . . . . �1 � � � d ��� � � ' �— k ,�i ,�.«.�+ � y'�� � - �.q�ea�w�w.1.re� y �� � __ 9 ! i•i3� /�o r � , �rn.► ., �-+ 'I . . . "�'ll I I . � � � � . �. �. l _ . � LL _ � . �- q 9 ,�(� � • j :��� ��►�-{ � ,«�.,� -�, --! . I` * . . ,eviw� .. -C � �S 4 .6(6bs� �: �i'rn'.4�A"- eia �,'r9r� T �d+A+dk� . )�w".+qpn'V`. i . :�! . - . �. . � . pY;IUnwrw- vRh � A . . - . . . .�i�w � ir..: .,�..._��� � . � � .. * :.. _ Ai�*� .}rw.wa.�. ' � Jl7 l�� ' _"x.+nh �V��. .� .w ~� . .�.wr+*+ . i � ...'tq.rN� - . _J.. ' � . . . . . . �� � (.eqir.. .i12 �12�r �146. . ° -- 9.itd , i ' , ,or�.r — � A r �r� ' � �+w . � � . . . (FW MiN'T � �� � lo� � .. ' . . Q �.�� ...1 � ,Pi�-: _{.,,.,,e ,R .'�a�Mw ,I � wu -� r.cs ��• �C (..�� � MWO.tYt � � - ,� . . I,, I{�l .., . . � ��r�l�/ . 'L p� �. t., �{y; -` ' 1' � '�t�• � p�l �': .�rNY � I � . . � ��� �J C �. � � r� ., ,u�,o+. . 4° ( � l,.� �inf� a , �� <lo . _ � ,-►+"'r"a�nnr � r � R� , ` � ,1 `lM�-` • ,. F ' ';. ' ' � - n�ra i � .�pW F 3 �- � �P� :�� . ; ��, � . Y� � , . j . v�a+wa.r+as:;n,` . ,�+,,; � t:: ' t�� ��'f�. � . .._pu.wK.a ww.i . . L3y � . . . . '�;r`,; .. f ri�� •�q'�; L y3a.�v.+oda `� °�: . w.wa�nq�. . . *�. Y 1�� .� .�: �_. ��s j . . ��� - ., �.�-:,� :,;;. . . . ,��,�t � ' � 4i sr - � C,oropl�dtG�2 i � ;�'} r .:y�f 4 r .�,t r �� 3 x .� >;����rh�hii '. ; ,rr�l���GS�W' t.�,,f .r J + � '�c� �.C�f� , . . . L�'��.t 'F�rr"}6,Y,F�� I`. �i!/i ..a.� {�(1f� }+ .� �±5{,�t. �"- . ."� .�.;.�.. ., ' . . . � ' t' . � �d,�. � �1.�"F 7 �i� . f.. J/� .y �T.�.�. � � t.. r^Yj x:�. � YWn�`I�rk:v �. . . ...., � .�.:: .. .. ... , . - . . .. . .' ' .. '�. .� .. . .. -. �. .... ..-�.,.. . . .. � :' .. .�. .... � . . .. �I Q�-oO6S MITSUBISHI ELECTRIC �I(.SLII�� HVAC Advanced Products Division Split-ductless A/C and Heat Pumps . � . . . . . . . . ��� : • � • • � � Job Name: Location:�7y �'. Date: 3 � Purchaser. �e%n ��jQ����� Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction Unit Designation: Schedule No.: _ _ _ :: � GENERAL FEATURES � IIII • !�a •Wall-mounted indoor unit for residential and commerciai _ �4�� ; �4'J,,. applications � _ ,�_ �,� � . .._ •Shiny-white-exterior plastic;compad design Indoor Und:PKA-A36KN. 'II � � �`*" • •Quiet operation--both indoor and outdoor units � ' •Wireless remote controller is induded r °��I , �M, ' •Seff-check function�ntegrated diagnostics i�� ' •Limited warranty.five years on parts and defeds and seven years 'M�ire�ss Remote ��� � ' on compresso►s Contrdle� 4�,. � �' �� - OPTIONAL ACCESSORIES `�` ------ OutdoorUnit PUY-A36NHA3 Indoor Unit Indoor Unit •Remote Temperature Sensor(PAC-SE4ITS-E) MCA.............................................. 1 A Fan Motor ................................... 0.57 F.L.A. Outdoor Unit Fan Motor Output.................. ... ...........56 W •M-NETAdapter(PAC-SF81 MA-E Airflow(Lo-Mid-Hi) ................705-810-920 Dry CFM •Air Outlet Guide(PAGSG59SG-�) •Wind Baffle(WB-PAZ) 635-730-830 Wet CFM Air Filter ........... ............. Polypropylene Honeycomb Sand Pressure Level(Lo-Mid-F�i....................43-46-49 d6(A) DIMENSIONS UNIT INCHES I MM W 46-1/16/1,170 D 11-5/8/295 H 14-3/8/365 Cooling* Weight................................... ..46 Ibs./21 kg Rated Capacity............ ...................34,200 Btu/h Extemal Finish.................... Munsell No. 1.OY 9.2/0.2 Minimum Capacity ............................12,000 Btu/h Field Drainpipe Size O.D............. ...........5/8"/16 mm SEER............ ..........................14.0 Btu/h/W Remote Controller....................... .........Wireless Total Input............................... .. 5,030 W •Rating Conditions(Cooling)-Indoor.BO°F(27°C)DB/67°F(19°C)WB. Outdoor.95°F(35°C)DB/75°F(24°C)WB. Outdoor Unit Compressor .................. DC Inverter-driven Twin Rotary Electrical Requirements MCA............ ................................ . 25 A Power Supply............ ........208/230V,1-Phase,60 Hz Fan Motor.................... ................ 0.75 F.L.A. BreakerSize........................................30 A Sound Pressure Level Voftage Cooling..................................... . . .48 dB(A) Indoor-Outdoor S1-S2 ......................AC 208/230V Indoor-Outdoor S2-S3 ............................DC 24V DIMENSIONS INCHES/MM Wireless Remote Controller...................... ...... DC W 37-3/B/950 D 13+1-3/16/330+30 OPERATING RANGE H 37-1/e/943 �ndoor�rtakeniremp. anaoor�rnekear7emp. Weight ...................................163 Ibs./74 kg Mauhnum ss^F oe,»^� wa »s^�es^c �e 6ctemal Finish............. .... .....Munsell No.3Y 7.8/1.1 coor�y MfnMnum srF�gc oe.srF�� we o^F--�e^c�os RefigerantType............... ................... R410A "With oplional wind baffle accessory installed.Ii not installed,the minimum Refigerant Pipe Size o.D. temperature will be 23°F(-5°C)DB. G85 Sld@................................5/8"/15.88 mm Liquid Side............. ...................3/8"/9.52 mm Max.Refigerant Pipe length............ .........165'/50 m Max.Refigerant Pipe Height Difference ............100'/30 m ConnectionMethod ................................Flared �4 � �I��V GR R �I ' / � � 1 � � Top aNe $a �s-nn eza.� 17431.7 Unit: inch (mm) �� �� a Len siae ppp y� Front siOs MouM1board aoWalvY '.4 ��� eS ■ C z-zsr.�z ♦ a�iuez s 5-irz�2��� n- z55 y��(s) A FmM stle(Gris tqen) �P���P Wqck M hale ———_______ por�Pp�9 OEFR0.5T5TMA BY lamp R ceiver Terminal dodc tor Outdoa und 7erminai bbck(or ower w I o 6on �Y� MAiemote�m�u�o�er PKA-A�Itnmodek) Fillarhook _ (F- °�" °t��"�' 1•3l1 30 '__'__' ' � � 17-15�32 441 pipe � 4-27 123 2-79,32 66 � 7 1 4 0 61/16(159) 23-1l32 585 Mse C�' S9l32 734 UntlerdEe � � Piping connection department �°"'°� � """" �O L'puid pipe Refigerant pipe:3/8 O.D(�9.52) e B Flared connection:3/8F ��� Sleeve '0f0wBf� Refigerant pipe: 5/8 O.D(�15.88) (�„a,a��Iy) Throu9h hde �Gas pipe Flared connection:S/8F �-�j 1e �5�����2 0 Drain hose 5/8(�16)O.D 75 Required soace(Indaor uiMl Air inlet �crod�w no�s a�c�q�o c � � @ � B A " Hir ounet � � \ C� N z Min.&21/32 220 Min2 50.5 � � Me�.2-27I32 72A 2-g�7 gg �� 2-f/t 65 � �-n,c�en � �3rszc�a. cemx meawemem�n�e �Z��+) � 4$11/Nl�)BON1oY .� ' s3 � .— ° ea.+mw ���'^a9 �,a�sn � ��� � ; �`� � � ; ������� ,a.,'°°','&„ _ _ h,aoorunnoIqw5h��. _' ' Z��Wu5l i-t S�e(�5.51 _ ' '_ iRl1751) 0 31/3t�'n) — — 12(it7 3 1-]tfl�50) �—� 1-15/J2�91.5) :.iviM�sl z-+5�rysesl � 11L1 100� _ 1Tf16(p3� 41 Hn — — 41�1015� 4]9!4(1]5) � —. — Syy�t]B.SJ St�xlui� _. . sahe(lnl i-9'18(19� 617q2�Ri� L7)fA�t/tl . . gV32�� nu�ss� i °'mqni n-vna��l t�nrz�sz7 it-srss�m.sl txtw(�tt) P � g a Z � a e @ ���� a � ,n,� � a a � � � w�'—^ � � a ,� �� a � � �n.�.q+q e�-`�. s..m "ti.^°rw v�VJ � - � o � v . � D rn � C � < mD 1ClearanceArea(Around unit 2 SERVICE SPACE 3 FOUNDATION BOLTS 4 PIPING-WIRING DIRECTIONS n Z � I R�uAk Intaka 1�U Shped robhed hob _ ^ The diagrem babw ahows a Dimensions of space needed Please secure ihe unft fumy Piping and vnring connecUons .� 4 Fo�mbuo�eon uio�wye> W � basic exampb. kr service accese are wilh 4 faundelbn(M10<W�Ig>) can be made from 4 diroclbns: y Explantbn of paAkular detaib are shown in the bebw diegrom. boBs.(BOlts end washew musl froM,righl,rear and below. �n airo> epo<za.yy i ream> � o �� gNen in ihe InsWllation manuals etc. be purchased bca�N.) ^ o � � � � sieeurimake A ti � S� � � �S� � ��d eFOWallonhdlMiphh � i�s "d Yi Q ,8 � � � C � � Fq� `a I�I q �t<i�21(J2>^� q _ � Mo'm ��� � / / / � � 1 ��tr0�wqe � 3 _ � R v R � 2-12xJfi Ovsl Mb� m �r,�iim� �> Service 6 ate ��"�"^..> FowWatlon 8op M10<WJPo> r <141UIH aivu� m n � � � Exam le of Notes • x D n 0�••�RetriperentGASpipeconnction�FLARE�15.88<5/B> �`37'��Z' TemWUiBbck m....RO(�peianlLIQUIDplpeconnectiot��FLARE�8.52cy8> R�erAhlnteke �y�py <i-1/18> EaMYrmYW 4ry...Poxvr�upplywl�rp o •1....Indiratbn of STOP VALVE wnneclbn bcalion. SldeAir Inteke �Mqnt...ineow/oulaoorwirip� . � O �O. Serhe parol HeMls HaMk HWe . O�� � O' Handle o000 � ' �' � .,, � , � - � ss ° '� 0 0�00 r � . � � Piping Knockout Hole Details „a.,,,,6> T Front�,� ��., When instalNnp ihe coMuiL �� $�c�S cadirok Set Ihe altachment lo Me iq-U1 i1Mt 6id8 O(Bach PeMI. d Reu WDkq cover T fD m � camurnae "9" 7��° ry+w� � �� m �� �� (2{thl-1/161tnodwul) . > GJU]T 2�27'1L14poa 12CaquMetlechneM Botlom tab ? A 16�7-2YJD ��1.Mip p �V� 7 71qN m ��� o � �N W� Q' FK�XWMhp hoM �$ 0�, Q ^, _ O (Nnockouq 3 7 � 111 � 8 ��8�°' °°` � � 3. � A y� • � — d 730 715 105 N6 Onln Mb � Q N T � (� FmM AoM ; p 1 1> A Nui' Adt /Q-19qY n 70<1�1B> �8Y1 (5-/7J<15/18>) CI Qi - ��y^, , Y� � � �o t� � r� (� � !� a - G 1 � � �a rn� � � N �C � o �� � �. n� O y =' O � 7 � m