HomeMy WebLinkAboutFP1_2 8 31 09 Flush 212" Single FDCHorn & Strobe Check Valve 2" copper pipe 1" test valve for anti freeze Weather proof 31 total heads 15 heads for lower level 16 heads for upper level MIS-REPRESENT THE EXACT LAYOUT OF THE LAYOUT & CALCULATIONS. AID THE AUTHORITY HAVING JURISDICTION WITH SPRINKLER SCHEMATIC MAY IN SOME CASES SPRINKLER SYSTEM. IT IS INTENDED TO HELP MILE HIGH DESIGN GROUP 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLER DESIGN COMPANY ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -THIS SET OF FIRE FIRE SPRINKLER SHOP DRAWINGS HAVE BEEN REVIEWED AND FOUND TO BE ACCEPTABLE BY TIMOTHY N. TROSTEL, JR -N.I.C.E.T. IV # 102055. SR. ENGINEERING TECHNICIAN -FIRE PROTECTION NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINNERING TECHNOLOGIES ____________________________________/____/____ Michael McGee Digitally signed by Michael McGee DN: cn=Michael McGee, o=Vail Fire & Emergency Services, ou=Deputy Chief, email=mmcgee@vailgov.com, c=US Date: 2009.08.31 15:59:16 -06'00'