HomeMy WebLinkAboutM10-0074NOTE: THIS PERMIT MUST BE POSTED ON JOBSI TE AT
MEOFVW '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
ASFR
Job Address: 760 POTATO PATCH DR VAIL
Location.....:
Parcel No...: 210106302015
OWNER MYHREN, VICTORIA H
355 CLAYTON ST
DENVER
CO 80206 -4228
APPLICANT RIO GRANDE CO.
3990 HAVANA ST
DENVER
CO 80239
License: 376 -M
CONTRACTOR RIO GRANDE CO.
3990 HAVANA ST
DENVER
CO 80239
License: 376 -M
05/20/2010
05/20/2010 Phone: (303) 375 -0913
05/20/2010 Phone: (303) 375 -0913
Desciption: ADDITION AND REMODEL: INSTALL ONE DIRECT VENT GAS FIREPLACE
Valuation: $3,300.00
ALL TIMES
Permit #: M10 -0074
Project #: PRJ10 -0007
Status ...:
ISSUED
Applied ..:
05/20/2010
Issued. .:
05126/2010
Expires. .:
11/22/2010
***** rt#########*********#*##############******#* # # # ### # # # ### # * * ***rt#* *## # # # #### # FEE SUMMARY***##*************#######*###***********#########**** rt * * ** * * * # #*# # # # ### # # # #*# * # * ****#
Mechanical Permit Fee --- > $80.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $184.00
Plan Check------------ - - - - -> $20.00 Use Tax Fee ------ > $0.00 Additional Fees------ - - - - -> $0.00
Investigation — --------------- > $80.00 TOTAL PERMIT FEE --- > $184.00
Total Calculated Fees - -> $184.00 Payments------------ - - - - -> $184.00
BALANCE DUE--- - - - - -> $0.00
APPROVALS
Item: 05100 BUILDING DEPARTMENT
05/25/2010 JRM Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTIONS ALL BEM E TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(
AM - 4 Pl�ll•.
Z co — 10
/ Si nature oflOwner or Coh�tra�cttor
I ockof �l� q_1
Print Na
Date
mechcan ical_permit_041908
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO
Statement
*************************************************************
* * * * * * * * * * * * * * * * * *
* * * * * * * * * * * **
Statement Number:
R100000548 Amount: $184.00 05/26/201010:34
AM
Payment Method:
Cash Init: JLE
-----------------------------------------------------------------------------
Notation:
DOUG SCHLEIF
Permit No:
M10 -0074 Type: MECHANICAL PERMIT
Parcel No:
2101 - 063 - 0201 -5
Site Address:
760 POTATO PATCH DR VAIL
Location:
Total Fees:
$184.00
This Payment:
$184.00 Total ALL Pmts:
$184.00
Balance:
$0.00
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code
-------------- - -
Description Current Pmts
--
-
MP 00100003111100
- ------------------------ - - - - -- ------
MECHANICAL PERMIT FEES
- - - - --
80.00
PF 00100003112300
PLAN CHECK FEES
20.00
PN 00100003153000
INVESTIGATION FEE (BLDG)
80.00
WC 00100003112800
-----------------------------------------------------------------------
WILL CALL INSPECTION FEE
4.00
- - - - --
Boller /Furnace Apollcstions MUST include_
❑ Mechanical Room Layout/Plan with Dimensions
❑ Combustion Air Duct Size and Location
d Flue or Vent Size
❑ Gas Piping Plan (If applicable)
o Heat Loss Calculations*
❑ Equipment Cut Sheets For Boiler /Fumace
*Nor required for same ske (BTU) Golder rw/acelnent wRh no system
cfianpes, or snow melt
i Project Street Address:
(Number) (Street) Su Ite #
i 1 )
Bulldlpg/Complex Name:
Contractor IAformatio
Fireplace APP111cations MUST include:
d Equipment Cut Sheets for Fireplaces/Log Sets
(Manufacturer's Info showing make, model & approval listing)
Office Use;
Project #: ' 00
Building Permit #: ILI C� Q
Mechanical Permit
Lot #: 5 Block # -2-- Subdlvision: XZW ( D" Palm_
I Company. 0 U
Y Address: �
Company �,, r Detailed Description of Work:
P �!3�X�,i�_��
1
City: State: Zlp: vv)
Contact Name.
Contact Phone: (use additional sheet N necessar
'
_ ry
E -Mail Q �� - oayll Gas Piping Included
To&of'�Gwtractor keglstratlon 14o. - �'Y� Gas piping by others
' a Wood to Gas Fireplace Conversion
,C(o Boiler Location:na ure (required) ;
I,.......,_....... ,............, ... - Interior ( ) Exterior { ) Othe
Property Information __.. -- 1...., .-_.. - -- ..•..__..�......»._.- er
Parcel #: Number of Existing Fireplaces: ^�
i (For parcel A contact Eagle County Assessors Office at 970-28 -8640 or Gas Appliances Gas Logs Wood/Pellet I
visit www- eagiecounty.us/patie) :_....__ _.._ .._._,,, - • - _, .__,......�.�.._,,,..
Tenant Name: Number of Prop" Fi
(Commercial Properties) Gas Appliances Gas Lags Wood /Pellet I
i Owner Name: Type of Building: I
Complete Valuation for Mechanical Permit. i0 Sln le -Famll Duplex y ( )Commercial ( )
g Y1 p ( ) Multl -Famtl
Restaurant( ) Other( )
Mechanical S:
Date Received:
MAY 19 2010
A Y-09
to 'd 'ON XVJ TOWN ON VA I V 43M OIOZ- 61 -AVN
MECHANICAL PERMIT
HEAT &GLO,.
No one builds a better Hre
Model:
SLR -B (COSMO)
NOTICE
DO NOT DISCARD THIS MANUAL
Important operating Read, understand and follow • Leave this manual with
and maintenance these instructions for safe party responsible for use
instructions included. Installation and operation. and operation.
A WARNING: 'If the Information In these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death,
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building. "
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This appliance may be Installed as an OEM installation In
manufactured home (USA only) or mobile home and must be
Installed In accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard Ibr Installation in Mobile
Homes, CAN/CSA Y24011014, in Canada,
This appliance is only for use with the types) of gas Indicated
on the rating plate.
i
GAS -FIRED
C UL US
LISTED
I A WAR NING
HOT SURFACES/
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause bums.
• DO NOT touch glass until it Is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing orptherfiammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been Supplied with an Integral barrier
to prevent direct contact with the tlxed glass panel. Oo
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly Install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas titter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualified personnel, Hearth & Home
Technologies suggests NFI certified or factory trained
• professionals, or technicians supervised by an NFI
certified professional.
Heat & Glo • SLR-8 • 2195 -900 Rev. G • 12/09
Owner's. Manual
Installation and Operation
ZO 'd 'ON XVA Wd 60:£0 a3M OIOZ- 61 -AVN
is
C. BTU Specifications
1
Listing and Code,
A. Appliance Certiftcation
MODEL: SLR -19
LABORATORY Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Fireplace Heater
STANDARD: ANSI Z21.88b -2008 CSA 2.33a -2008
Vented Gas Fireplace Heaters
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles ", and "Gas Fired Appliances for
Use at High Altitudes ".
NO77CE. This Installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSi 2223. i- tatest edition in
the U.S.A. and the CAN/CGA B149 installation Codes in
Canada.
NOT iNTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance, It should not be
Factored as primary heat In residential heating calculations.
B. Tempered Glass Specifications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as defined by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certified to the requirements
of ANSI 297.1 and CPSC 16 CFR 1202 (Safety Glazing
Certification Council SOCC# 1596 and 1597. Architectur-
al Testing, Inc. Reports 02- 31919.01 and 0241917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 "Certification and labeling requirements"
which refers to 15 U.S. Code (USC) 2063 stating "...Such
certificate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered."
Some local building codes require the use of tempered
glass with permanent marking in such locations, Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
Models
MAXInum
WIMUm
adfic■
rO.& or Canada)
Input
BTU&
Input
gn1M
am
MINIM
US
(0 -2000 KTJ
28,000
NIA
lsd2
SLR -B (NO)
CANADA
(2000 -4500 FT)
21,870
NIA
"a
US
(0-2000 FT)
25.000
NIA
.057
SLR-8 (LP)
CANADA
(2000 -4u00 Fr)
23,500
2
N/A
#54
D. High Altitude installations
NOTICE If the heating value of the gas hat been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA. Reduce input rate 4% for'each 1000 feet
above 2000 feet.
• In CANADA. Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifice size,
E. Non- Combustible Materials Specification
Material which will not Ignite and bum. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof,
Materials that are reported as passing ; I AStM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Fumace at 750 9 C and UL763 shall be
considered non - combustible materials.
F. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and bunt, whether flame proofed or not, or plastered or
unplestered shall be considered combustible materials.
G. Electrical Codes
NOTICE. This appliance must be electrically wired and
grounded in accordance wjM local codes or in the absence
of local codes, with National Electric Code ANSi /NFPA
70- latest edition or the Canadian Electric Code CSA
022.1.
• A 110 -120 VAC circuit for this product must be protected
with ground -fault circuit interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
Heat & Gla • SLR•9. 2195 -900 Rev. G • 12/08
£0 'd ON XVA Wd 60:£0 03M 010Z- 61-AEiW
Note: The following requirements reference various
Massachusetts and national codes not contained In this
document.
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
Installed in every dwelling, building or structure used in
whole or in part for residential purposes, Including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above finished grade In the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas fitter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back -up is Installed on the floor
level where the gas equipment Is to be installed. In addi-
tion, the installing plumber or gas fitter shall observe that
a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be' the
responsibility of the property owner to secure the services
of qualified licensed professionals for the Installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back -up may be installed on the next adjacent
floor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be Installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required In accor-
dance with the above provisions shall comply with NFPA
720 and be ANSI /UL 2034 listed and IAS certified.
Signage
A metal or plastic identification plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly In line with the
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read,
in print size no less than one -half (112) In. in size, "GAS
VENT bIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS".
Inspection
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
Installation unless, upon Inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
In accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment Is exempt from 248 CMR
5.08(2)(a)1 through 4:
• The equipment listed In Chapter 10 entitled "Equipment
Not Required To Be Vented" in the most current edition
of NF'PA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fu-
eled equipment installed In a room or structure separate
from the dwelling, building or structure used in whole or
In part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
A complete parts list for the venting system . design or
venting system.
Gas Equipment Venting System NO Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not pro-
vide the parts for venting the flue gases, but Identifies
`special venting systems ", the following requirements
shall be satisfied by the manufacturer.
• The referenced "special venting system" Instructions
shall be included with the appliance or, equipment in-
stallation instructions; and
The "special venting systems" shall be Product Ap-
proved by the Board, and the instructions for that sys-
tem shall Include a parts list and detailed installation
Instructions.
A copy of all installation instructions for all product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting Instructions, all parts lists for venting
Instructions, and /or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Heat & Glo • SLR -5. 2195 -900 Rev. G • 12109
60 'd 'ON Xdd Wd 60 ; £0 4dM 010Z -6I -M
06 -22 -2010 Inspection Request Re orting Page 11
N Dm Vail, C - City OF
Requested Inspect Date: Wednesday, June 23, 2010
Assigned To: CGUNION
Inspection Type: MECH
Inspection Area: CG
Site Address: 760 POTATO PATCH DR VAIL
A/P /D Information
Activity: M10 -0074 Type: B -MECH Sub Type: ASFR Status: ISSUED
Const Type: Occupancy: Use: Insp Area: CG
Owner: MYHREN, VICTORIA H.
Contractor: RIO GRANDE CO. Phone: (303) 375 -0913
Description: ADDITION AND REMODEL: INSTALL ONE DIRECT VENT GAS FIREPLACE
Requeste Inspection(s
Item: 390 MECH -Final Requested Time: 01:00 PM
Requestor: RIO GRANDE CO. Phone: (303) 375 -0913
Comments: 390 -4529 0
Assigned To: CGUNION � T Entered By: JMONDRAGON K
Action: I o lD Time Exp: `
11104L
Inspection History
Item: 200 MECH -Rough
05/27/10 Inspector: cg Action: CR CORRECTION REQUIRED
Comment: 1 ) NEED INT LLATION MANUAL ON SITE
2) UNABLE TO VIEW VENT TERMINATION AND PORTION BEHIND DRYWALL
Item: 310 MECH- Heating
Item: 315 PLMB -Gas Piping
Item: 390 MECH -Final
REPT131 Run Id: 11620