Loading...
HomeMy WebLinkAboutB07-0045TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD /ALT COMM BUILD PERMT Job Address: 2077 N FRONTAGE RD WEST VAIL Location.......: ROCKY MOUNTAIN REPROGRAPHICS Parcel No....: 210311416030 03/13/2007 OWNER WEST VAIL ASSOCIATES LTD 03/13/2007 2121 N FRONTAGE RD W 101 09/25/2007 VAIL Plan Check - -- > CO 81657 $0.00 Additional Fees ---------- > APPLICANT WIRTH MANAGEMENT INC 03/13/2007 2111 N.FRONTAGE RD. WEST, SUITE J VAIL Will Call - - - - -> CO 81657 Payments ------------------- > License: 690 -B CONTRACTOR WIRTH MANAGEMENT INC 03/13/2007 2111 N.FRONTAGE RD. WEST, SUITE J VAIL CO 81657 License: 690 -B Permit # B07 -0045 Project # PRJ07 -0086 Status ...: ISSUED Applied ...: 03/13/2007 Issued ...: 03/29/2007 Expires.....: 09/25/2007 Phone: (970)479 -1082 Phone: (970)479 -1082 Desciption: ROCKY MOUNTAIN REPROGRAPHICS -DEMO PARTITION WALL, CONSTRUCT NEW WALL AND ADD AN OFFICE SPACE Occupancy: B Type Construction: VA Valuation: $15,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 ********************************** s * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************ a**** * * * * * * * * * * * * * * * * * *s * * * * * *s * * * ** Building - - - - -- > $251.25 Restuarant Plan Review -- > $0.00 Total Calculated Fees -- > $417.56 Plan Check - -- > $163.31 Recreation Fee-------- - - - - -- > $0.00 Additional Fees ---------- > $0.00 Investigation -> $0.00 TOTAL FEES ------------- > $417.56 Total Permit Fee --------- > $417.56 Will Call - - - - -> $3.00 Payments ------------------- > $417.56 BALANCE DUE --------- > $0.00 Approvals: Item: 05100 BUILDING DEPARTMENT 03/23/2007 jplano Action: CR Correction letter sent, F: \cdev \CHRIS \PERMIT.COMMENTS \B07 - 0045 \B07- 0045.DOC 03/29/2007 JPLANO Action: AP REVISIONS REVIEWED AND APPROVED Item: 05400 PLANNING DEPARTMENT 03/13/2007 JS Action: AP NO EXTERIOR CHANGES Item: 05600 FIRE DEPARTMENT 03/14/2007 DRhoades Action: APPR Approved as noted: 1. Alarm and sprinkler systems in this unit must be complatible with existing building systems. 2. An alarm application, with shop drawings, must be CONDITIONS OF APPROVAL Permit #: B07 -0045 as of 03 -29 -2007 Status: ISSUED Permit Type: ADD /ALT COMM BUILD PERMT Applicant: WIRTH MANAGEMENT INC (970)479 -1082 Job Address: 2077 N FRONTAGE RD WEST VAIL Location: ROCKY MOUNTAIN REPROGRAPHICS Parcel No: 210311416030 Applied: 03/13/2007 Issued: 03/29/2007 To Expire: 09/25/2007 Description: ROCKY MOUNTAIN REPROGRAPHICS -DEMO PARTITION WALL, CONSTRUCT NEW WALL AND ADD AN OFFICE SPACE Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. submitted and approved by VFES and shall comply with NFPA 72 and Town of Vail Standards. 3. A fire sprinkler application, with shop drawings, must be submitted and approved by VFES and shall comply with NFPA 13 and Town of Vail Standards. 03/15/2007 DRhoades Action: APPR All smoke detectors shall be changed out prior to any work occurring, by a registered alarm company, with heat detectors. After all construction work has been completed, the smoke detectors shall be reinstalled and inspected /tested by VFES. See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCF/�Y TELEPHONE AT 479 -2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. �� SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R070000381 Amount: $417.56 03/29/200703:19 PM Payment Method: Check Init: LT Notation: Wirth Management / 2717 ----------------------------------------------------------------------------- Permit No: B07 -0045 Type: ADD /ALT COMM BUILD PERMT Parcel No: 2103 - 114 - 1603 -0 Site Address: 2077 N FRONTAGE RD WEST VAIL Location: ROCKY MOUNTAIN REPROGRAPHICS Total Fees: $417.56 This Payment: $417.56 Total ALL Pmts: $417.56 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 251.25 PF 00100003112300 PLAN CHECK FEES 163.31 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNi 47 O �v Project#: 3--- • Building Permit #: TOWN OF VAIL BUILDING PERMIT APPLICATION From Rd. Separate Permits are required for electrical, plumbing, mechanical, etc.1 7s S. VaS, Cokm*1i sitar cnNTReP_rnR IMOnDUATIMI CQMPLETE VALUATIONS FOR BUILDING- PERMIT Labor & Materials BUILDING: $ � ID o0 0 ELECTRICAL: $ S boa OTHER: PLUMBING: $ MECHANICAL: $ & TOTAL: $ Q o 0 r-ar PareW $ G �sn� f`afan/v' d.�eae�...� n/ .e ss e'fn _ ease sc,Jn ­.R-2. .- - - - -- - - -'- - - - -- -- - - - OR OFFICE USE ONL Job. Name: Y`POfv�to� o C Job Address: r 04 V4 Q le Legal Description Lot: Block: Filing: Subdivision: \lol AC4.s J(i�6I SSoc. Q A Address: 2t 11 i „ � one: • dress: t �h 4 00 ,� Ph one: *Phone: Engineer: Address: Deta descriptiotf work: ►�, GXmia.% W l ^eta U0,111 Adj oj , u Work Class: New( Addition ( ) Remodel Repair ( ) Demo ( ) Other ( ) Work Type: Interior M Exterior ( ) Both ( ) Does an EHU exist at this location.- Yes ( ) No ( ) Type. of Bldg.: Single -fWMY ( ) Two ( ) MuWfamily ( ) Commercial Restaurant ( ) oftw ( ) No. or Existing Dwelling Units in this building: No. of Accommodation Units in this building: VT of QM&M Existi : Gas Appliances Gas Logs Wood/Pellet Wood Bumi Z f N2M= of fi P : Gas Appliances Gas Logs Wood/Pellet Wood Bumi NOT ALLOWED Does a Fire Alarm t Yes No ( ) Does a ire Sprinkler System Exist: Yes ), No OR OFFICE USE ONL 0 O TOWN ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION . I have included the asbestos test and report with my building permit application applicant signature OR date • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature OR date • The building was constructed after October 12, 1988. S �c�11 fia 6 rI e- - 'QVt d w a S It 0" *, Z, P(s S. 03 It z appli nt signature dat The date of construction was original construction date F: \cdev \FORMS \Pennits \Building \building_permitDOC Page 4 of 16 02/09/2005 BUILDING PERMIT ISSUANCE TIME FRAME Imo. If this permit requires a Town of Vail Fire Department Approval, Engineer's (Public Works) review and approval, a Planning Department review or Health Department review, and a review by the Building Department, the estimated time for a total review will take as long as three (3) weeks. All commercial (large or small) and all multi - family permits will have to follow the above mentioned maximum requirements. Residential and small projects should take a lesser amount of time. However, if residential or smaller projects impact the various above mentioned departments with regard to necessary review, these projects may also take three (3) weeks to review and approve. Every attempt will be made by this department to expedite this permit as soon as possible. I, the undersigned, understand the plan check procedure and time frame. I also understand that if the permit is not picked up by the expiration date, that I must still pay the plan check fee and that if I fail to do so it may affect future permits that I apply for. Agreed to by: PH name / gnature p Project Name: ° �c "� �R (��6 �� °�' �� CS Date: C 11 Zl d F:\ dev\FORMS\Perrriits\Building\building_permit.DOC Page 5 of 16 02/09/2005 _ -r �n L _ F :C H- I -B I T "An LEGAL DESCRIPTION tercel cf.land lying -in the East o*ie -half of the Southeast e- quax[e= of Section II,-Township 5 South, Range 81 West of ,F 3th Pzirecipal Meridian, Eagle County, Colorado described as, `{ :Beginning at the Northeasterly corner of Lot 3, Vail Das ne, Filing No. 3; thence along the Southeasterly right -of -way �` 2,ne of Chamonix Lane on the follo;rir.g two courses: (1) 57.35 clang the arc of a 227.38 fcc_ radius curve to the sight ? trhose central angle is 14 °27`06" and whose long chord be - -ars i. 48 °12'56" E 57.20 feet to a point of tangent; and (2) Ni 5 5 26 129 E 198.04 feet along said tangent; ti.ence S 43 °06'35" E 469.14 feet to a point on the Northerly lir.: of the Interstate Highway To. 70 Right -of -Way; thence Southwest ?rly along said Northerly line on the following two courses: (ij S 44 °02'5C" W 11.00 feet to a point of curve; and (2) 243.43 feet along the arc of said curve to the right whose radius is 5550.00 feet, central angle is 2 °30'47" and whose long chord bears S 45 °18'20" W 243.41 feet; thence N 42 ° 57 "50" W and along the Northeasterly line of said Lot 3. 5(7.21 feet to the point of beginning, containing 124,799.05 - square feat or 2,8650 acres, more or less. fir•_:` . A rt, Chapter 4. Accessible Routes r - - - - - - - - - , I � I I I I I I I S E c I co r I I I I (a) Front Approach, Pull Side r ------- - - - - - 7 I I 14 I I I I I ICC /ANSI A117.1 -2003 *If both closer and latch are provided r- -r - - - - - -- 18min I I n I 445 12 min I I E o 305 I I 00 r I I v I I I I (b) Front Approach, Push Side LO N LO (c) Hinge Approach, Pull Side *If both closer and latch are provided **48 min (1220) if both closed and latch provided 12 min* 305 r ----- - - - - -� I I j 22 min C m 1 1 560 E °I I I C\1 T I I Z' I I I (e) Hinge Approach, Push Side - - - - - - -� 4> I I I I F O 42 min I v r 1 1065, 1 i° I I I I - - - -- (d) Hinge Approach, Pull Side *54 min (1370) if closer is provided C C E cc I ---- - - - - -- I I ----- - - - - -- I4 I 1 I 1 24 min 1 6 I F o 10 I � T I 1 (g) Latch Approach, *48 min (1220) Push Side if closer is provided Fig. 404.2.3.1 Maneuvering Clearance at Manual Swinging Doors 18 24 min 610 (f) Latch Approach, Pull Side y i r ro 011 Department of Community Development Bui lding Safety and Inspection Services 755outh Frontage Road Vail, Colorado 81657 970 -479 -2138 FAX 970 -479 -2452 www. vailgov.com BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: Contractor /Applicant Wirth Management FAX /Email #: 479-1083 Architect Sederberg Mayhew proj #31002 476 -4608 NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: 2 John Plano, Building Plans Examiner 03/23/2006 B07 -0045 Rocky Mountain Reprographics 2111 N. Frontage Road B unknown unknown unknown The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. The following comments will need to be addressed prior to issuance of a building permit; For processing: • Please submit 2 complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. • Please respond in writing to each comment by marking the attached list or creating a response letter. Indicate which plan sheet detail, specification or calculation shows the requested information Please send revisions to the attention of the plans examiner with the building permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, signature, registration number and date on the cover page of any structural calculations, all structural details and structural sheets of the plans For commercial or multi - family projects all sheets of the plans must be stamped. f 1 Architectural Comments: ik'A1.0: Under "Project Data" change the code reference to the 2003 International Building Code. - A1.0: Provide code analysis for the building and state the type of construction under "Project Data ". t ,3 A1.0: Indicate if separated or non - separated uses are being used. Show uses and occupancy classification for the adjacent spaces, including the upper level. ,4"' A2.0: Show the existing floor /ceiling assembly above and the fire rating it was built to. Unable to determine if the drop ceiling is part of a rated assembly. 0 Show the property line on the north side of the building to verify if the new door is allowed and /or if it is required to be fire rated. General: Provide required plumbing fixtures or show location of existing public restrooms if applicable. (IBC Chapter 29) A2.0: Add an exit sign at the start of the new corridor. (IBC 1011) �9 A2.0: Provide 12" maneuvering clearance on the push side of door #4. (ANSI A117.1- 404.2.4) V Provide structural drawings to add the new door #4 in the existing exterior wall. M" energy compliance for lighting. (IECC 805) A ComCheck compliance certificate is a method the town is accepting. The software can be downloaded at energycodes.gov. Provide engineer stamped electrical drawings. Include anticipated equipment loads and panel schedule. Show existing service and check that it has the capacity for the new and existing loads. Provide list of hazardous material and how it is to be stored. Will a control area be utilized, listed ventilated cabinets? Are the amounts under the allowable per Table 307.7(1) or (2). Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.977 -6278 jplano @vailgov.com F:\cdevkCHRIS\PERMrr.COMMENTS\BO7-0045\BO7-0045.DOC r w FILE MODE -------- - - - - -- 764 MEMORY TX * * COMMUNICATION RESULT REPORT ( MAR.23.2007 OPTION REASON FOR ERROR E -1) HANG, LIP OR LINE FAIL E -3) NO ANSWER ADDRESS (GROUP) --------------- 94764608 1 :52PM ) TTI RESULT --- - - - --- - - - - -- OK E -2) BUSY E -4) NO FACSIMILE CONNECTION P. 1 PAGE P. 212 Department of Community Development Building Safety and Inspection Services 75 South Frontage Road Ball, Colorado 81657 971 -479 -2138 FAX 970 -41 -2452 Imu vailgov.Com Ri AIL DING: SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: Contractor /Applicant Wirth Management FAX /Email #: 479 -1083 NUMBER OF PAGES: FROM DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: nflrrl In wvw f±onu in. Architect Sederberg Mayhew proj #31002 476 -4608 2 John Plano, Building Plans Examiner 03/23/2006 B07 -0045 Rocky Mountain Reprographics 2111 N. Frontage Road 0 P. 1 COMMUNICATION RESULT REPORT ( MAR.23.2007 1:50PM ) TTI FILE MODE OPTION ADDRESS (GROUP) RESULT PAGE ------------------------------------------------------------------------------------------------- 763 MEMORY TX p 94791053 OK P. 2/2 ------------------------------------ REASON FOR ERROR E -1) HANG UP OR LINE FAIL E -3) NO ANSWER E -2) BUSY E -4) NO FACSIMILE CONNECTION Department of Community Development Building Salty and Inspection Services 75 South Frontage Road Vail, Colorado 81657 970 - 479 -2138 FAX 970179 - ,2952 wvtiv. vailgov.cum BUILIUNG SAFETY AND PECTION VICES PLAN REVIEW COMME N TO ContractorlAp�licant Wirth Management FAX /Email #: 479 -1083 Architect Sederberg Mayhew prof #31002 476 -4608 NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: 2 John Plano, Building Plans Examiner 03/23/2006 B07 -0045 Rocky Mountain Reprographics 2111 N. Frontage Road B March 28, 2007 Town of Vail, Building Safety and Inspection Services Attn: John Plano, Building Plans Examiner 75 South Frontage Road Vail, CO 81657 Re: Permit #1307 -0045 Dear Mr. Plano: The following comments are in response to your Architectural Comments dated March 23, 2007: V-< Change shown on sheet A1.0. � Change shown on sheet A1.0. ;,3' Non - separated uses are being used; other changes shown on sheet A1.0. Existing ceiling /floor assembly shown on 2/A2.0. Existing assembly built to minimum of 2 -hour rating, dropped ceiling is not part of rated assembly. See also attached photo. Change shown on sheet A1.0; see also attached legal description. LEr No plumbing fixtures required, public restrooms, including accessible restroom, are provided as shown on sheet A2.0. a: Change shown on sheet A2.0. C ,gr Change shown on sheet A2.0. Also, see attached ANSI sheet. 5'5.e Change shown on sheet A2.0, detail 5. ComCheck compliance certificate is attached. Please note: 2'x 2' U -tube option not available, equivalent bulb and wattage used in calculations. Y1 .See attached Electrical sheets. L� No hazardous materials to be stored. Sincerely, S GERBERG, MAYHEW & ASSOCIATES, ARCHITECTS Kurt A. Segerberg, A. I. . President KAS /Ikj enc. Segerberg, Mayhew & Associates Architects, P.C., A.I.A. Mail: P.O. Box 4700 Vail, CO 81658 e -mail: info@smarchs.com http: / /www.smarchs.com Main Office: Eagle -Vail • 101 Eagle Road, Bldg. 6 • Avon, CO 81620 • phone: 970 476 4433 • fax: 970 476 4608 Denver Office: 12600 West Colfax Avenue, Suite A -140 Lakewood CO 80215 phone: 303 623 3355 fax: 303 623 2262 V 03 -09 -2010 Inspection Request Re orting Page 1 4,00 pm Vail, C� OF Requested Inspect Date: Wednesday, March 10, 2010 Inspection Area: JP Site Address: 2111 N FRONTAGE RD WEST VAIL ROCKY MOUNTAIN REPROGRAPHICS A/P /D Information Activity: B07 -0045 Type: A -COMM Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: VA Insp Area: JP Owner: WEST VAIL ASSOCIATES LTD Contractor: WIRTH MANAGEMENT INC Phone: (970)479 -1082 Description: ROCKY MOUNTAIN REPROGRAPHICS -DEMO PARTITION WALL, CONSTRUCT NEW WALL AND ADD AN OFFICE SPACE te al BLDG -Fin C/O Reque or: WIRTH MANAGEMENT INC e �o nts: 390 -2015 >si ed To: JMONDRAGON ction: Time Exp: Requested Time: 08:00 AM Phone: 970 479 -1082 -or- 970 390 -2015 - cell Entered By: JMONDRAGON K Inspection History Item: 501 PW- Access /Staging /Erosion Item: 21 PLAN -ILC Foundation Plan Item: 30 BLDG- Framing ** Approved ** 05/04/07 Inspector: JRM Action: AP APPROVED Comment: FRAMING APPROVED FOR OFFICE SPACE AND HALL WAY ONLY Item: 22 PLAN -ILC FRAMING Item: 60 BLDG - Sheetrock Nail ** Approved ** 05/09/07 Inspector: JRM Action: AP APPROVED Comment: Item: 532 PW -TEMP. C/O Item: 533 PLAN -TEMP. C/O Item: 530 BLDG -Temp. C/O ** Approved ** 05/24/07 Inspector: JRM Action: AP APPROVED Comment: Item: 539 PW -FINAL C/O Item: 538 FIRE -FINAL C/O Item: 540 BLDG -Final C/O REPT131 Run Id: 11115 E07 -0040: Entries for Item: 190 - ELEC -Final 09:19 01/31/2013 Action Comments By Date Unique_ Ke CR SUPPORT FIXTURES FROM STRUCTURE, shahn 05/17/2007 A000100 NOT PIPING. 787 OFFICE NEEDS 2ND SWITCH OR OCCUPANCY SENSOR PER IECC. CABLES CANNOT BE LAYING ON GRID. SECURE THE LOOSE END OF WIRES TO GRID PER NEC 300. STEEL TIE WIRE WAS ALLOWED TO BE USED. AP CORRECTION FROM 5/17/07 APPROVED. shahn 05/18/2007 A000100 813 Total Rows: 2 Page 1