HomeMy WebLinkAboutB10-0124NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWiVOFVAIi
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD /ALT MF BUILD PERMIT
Job Address: 714 LIONSHEAD PL VAIL
Location......: UNIT 683, MARRIOTT
Parcel No....: 210107205017
OWNER ARTINIAN, RON 06/01/2010
5 BRISTOL DR
MANHASSET
NY 11030
APPLICANT T. HORN ENTERPRISES INC.
PO BOX 552
EDWARDS
COLORADO 81632
License: 926 -B
CONTRACTOR T. HORN ENTERPRISES INC
PO BOX 552
EDWARDS
COLORADO 81632
License: 926 -B
Description:
CONSTRUCT ROOF -TOP DECK
Occupancy: R2
Type Construction:IB
Permit #:
B10 -0124
Project #:
PRJ10 -0106
Status..
ISSUED
Applied ..:
06/01/2010
Issued ...:
06/11/2010
Expires ...:
12/08/2010
Valuation: $21,500.00
Total Sq Ft Added: 0
__________________________________________________ ________________•_____________= FEE SUMMARY =_______________________________________________ ______________________________•
Building Permit Fee ------ > $349.25 Will Cal Fee --------------------- > $4.00 Total Calculated Fees ------------- > $810.26
Plan Check--------------- - - - - -> $227.01 Use Tax Fee --------------------- > $230.00 Additional Fees ----- — ---------------- > $75.00
Add'I Plan Check Hours -> $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES--------- - - - - -> $885.26
Investigation------------ - - - - -> $0.00 Recreation Fee------------ - - - - -> $0.00
Payments ------------------------------- > $885.26
Total Calculated Fees--- - - - - -> $810.26 BALANCE DUE ------------------------ > $0.00
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM - 4:00 PM. —
��_ 0
Signature of Owner or Contractor Date
if`�w0if r-r/ �
Print Name
06/01/2010 Phone: (970) 390 -5111
06/01/2010 Phone: (970) 390-5111
b Id — a It_co nstructio n_perm it_041908
APPROVALS
Permit #: B10 -0124 as of 06 -11 -2010 Status: ISSUED
Item: 05100 BUILDING DEPARTMENT
06/08/2010 cg Action: AP
Item: 05400 PLANNING DEPARTMENT
06/01/2010 bgibson Action: AP plans routed to Al
Item: 05600 FIRE DEPARTMENT
06/02/2010 McGee Action: AP
See the Conditions section of this Document for any that may apply.
bld_a It_construction_permit_041908
CONDITIONS OF APPROVAL
Permit #: B10 -0124 as of 06 -11 -2010 Status: ISSUED
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: 14
(BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
Cond: CON0011458
The new exterior lights shall be the Bridge B50 T50 fixture
that received design review approval.
bld_a It_constru ction_perm it_041908
TOWN OF VAIL, COLORADO Statement
Statement Number:
R100000663 Amount: $885.26 06/11/201008:37 AM
Payment Method:
Check Init: SAB
Notation: 3189 T.HORN
ENTERPRISES
-----------------------------------------------------------------------------
Permit No:
B10 -0124 Type: ADD /ALT MF BUILD PERMIT
Parcel No:
2101- 072 - 0501 -7
Site Address:
714 LIONSHEAD PL VAIL
Location:
UNIT 683, MARRIOTT
Total Fees: $885.26
This Payment:
$885.26 Total ALL Pmts: $885.26
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code
-------------- - - -
Description Current Pmts
- --
BP 00100003111100
------------------------ - - - - -- ------ - - - - --
BUILDING PERMIT FEES 349.25
CL 00100003123000
CONTRACTOR LICENSES 75.00
PF 00100003112300
PLAN CHECK FEES 227.01
UT 11000003106000
USE TAX 4% 230.00
WC 00100003112800
-----------------------------------------------------------------------
WILL CALL INSPECTION FEE 4.00
- - - - --
Separate permits are required for electrical, plumbing, mechanical, fireplace, etc.
Project Street Address: 6 F3
') / , k) L:e44s e'd C : r Roar
(Number) (Street) (Suite / #
Building /Complex Name: 41 2M Aff: eft
Contractor Information:
Company: T, Hoe n £o. �.c • n �: s e s v� e
Office Use: �f , ,
Project #: P "� to d t 0 �D
DRB #: V V6t000gC; rL
Building Permit #: 1�2I C) — ® 1 2 T
Lot #: Block # Subdivision: VO ( 6I-
Company Address: P. D_ /30X S S 2 Detailed Scope and Location of Work: 1 b x 1 - 6
City: State: D. Zip: 8/ 6 3 2 De k 1 top o /z R o v P
Contact Name: t J J he r o i f a% c ad P L U le R g: C Dee-1
Contact Phone: 3)19 - 3 9a - S r
(use additional sheet if necessary)
E -Mail LAv1 la') ee.%,'vi.fe 1 . 11 of
Town of Vail Contractor Registration No.: Sol 6 ` i3
Work Class:
New ( ) Addition (>e_1) Remodel ( ) Repair ( ) Other ( )
X Work Type
Contractor Signature (required) I Interior ( ) Exterior 54 Both ( )
Properiq Information Type of Building:
E 2-lp #t o ?.2 OS o /) Single-Family( ) Duplex( ) Multi-Family( j
I #, contact Eagle County Assessors Office at 970 - 328 -8640 or 4
l ia
Commerc ���� Other(
)
visit www.eaglecounty.us/patie) 1
Tenant Name: Does a Fire Alarm Exist? Yes (pQ No( )
Owner Name: h I`7�
JJ • Monitored Alarm? Yes (QQ No( )
Oh i / � h
Does a Sprinkler System Exist? Yes (>CL, No( )
i
Valuations (Labor &Materials) # & Type of Existing Fireplaces: Gas Appliances
t
Gas Log Wood /Pellet Wood Burning
Building: $ 'ap o0o
Plumbing:
Electrical:
Mechanical: (including fireplace)
Total:
$ /,5700
# & Type of Proposed Fireplaces: Gas Appliances
Gas Log Wood /Pellet Wood Burning
Date Received: D L� V
MAY 2 2010
TOWN OF VAILR
01- Jan -10
BUILDING PERMIT APPLICATION
Vail, Colorado
Denver, Colorado
Frisco, Colorado
Rifle, Colorado
Monroe & Newell
May 27, 2010 Engineers, Inc.
K.H.Webb Architects, P.C.
710 South Frontage Rd West, Suite A
Vail, CO 81657
Re: Artinian Roof Top Terrace, Vail, CO (M &N #8225.00)
Dear Kyle:
As requested, Monroe & Newell Engineers, Inc. has reviewed your plan dated September
1, 2009 for the project. The purpose of our review is to provide our opinion of the
structural impact of the project to the existing building.
The existing building is a precast concrete structure using precast double tees, precast
beams and columns, and precast load bearing/shear walls.
Based on our review of the existing structural drawings, it is our opinion that the existing
framing is capable of supporting the additional dead load of a palletized "wood" deck.
Occupancy live load requirements are less than the design snow load and are acceptable.
The concentrated load from the center support column of the proposed circular stair
needs to be distributed to the supporting double tee(s) below. A base plate of /4 "xl' -0"
wide x4' -0" long centered below the column is required with the 4' -0" direction
perpendicular to the tee legs below.
If you have any questions or comments, please call.
MONROE & NEWELL ENGINEERS, INC.
Very truly yours,
QikV
Peter Monroe, P.E.
Principal
CW Colorado
. tCAR Ww+d7teM+eKa� n,rre d:+Wecle
Platinum Sponsor
:e omemi"Yem
www.monroe- newell.com
� MAY 2 8 2010
TOWN OF VAIL
1701 Wynkoop Street . Suite 200 • Denver, Colorado 80202
(303) 623 -4927 • FAX (303) 623 -6602 • email: denver ® monroe- newell.com
M. D. Moller Compare
P.O. BOX 1508 Edwards, CO 81632 (970) 376.8785
Mi ke@Monerelectric.com
5-27-10
Attn: Kyle Webb
Re: Artinian Electrical Evaluation
Kyle,
After my visit at the Artinian residence yesterday, it is my opinion that it will be achievable to
add the small electrical load per your electrical plans.
First, we will be gaining 1- 20amp 120volt circuit due to eliminating the one rooftop ventilation
unit. As far as the additional electrical per your plans, it is achievable by adding the new load of
300 watts (6- 12volt, 50 watt deck lights) onto an existing electrical circuit in the rooftop
electrical panel. Essentially, we will not be adding any additional load to the existing panel, only
extending existing circuitry.
In the end we will actually be potentially gaining overall electrical service load if you account for
the deletion of the rooftop ventilation (120volt, 20amp motor load) and only adding 300 watts,
12volts (seasonal lighting) of low voltage lighting.
Please feel free to contact me with any questions (376- 8785).
Thank you,
President / Master Electrician
License #5958
?MikeMo
t
07 -23 -2010
( (t 5 -- ((fib
Inspection Request Reporting
va rn
il _ r-i+ n
Page 6
Requested Ass ect D te : CGUNI ON m P
July 26, 2010 �l� ��' ()(
Inspection Type: BLDG
Inspection Area: CG
Site Address: 714 LIONSHEAD PL VAIL
UNIT 683, MARRIOTT
A/P /D Information
Activity: B10 -0124 Type: A -MF Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: IB Insp Area: CG
Owner: ARTINIAN, RON
Contractor: T. HORN ENTERPRISES INC. Phone: (970) 390 -5111
Description: CONSTRUCT ROOF -TOP DECK
Requested Inspection(s
Item: 90 BLDG -Final Requested Time: 08:30 AM
Requestor: T. HORbLENTERPRISES INC. Phone: (970) 390 -5111
Comments: 390 -
Assigned To: CG U N Entered By: JMONDRAGON K
Action: Time Exp.� �
Comment: RAIL TO SAFPTYTER><7TN7'1 AT BOTTOM
OPFIEN RISERS MUST BE LESS THAN 4" OPENING
3/8" MAXIMUM VARIATION ON RISERS ALLOWED. CHECK BOTTOM RISER
ELECTRICAL FINAL REQUIRED
Inspection History
Item: 226 FIRE DEPT. NOTIFICATION
Item: 30 BLDG - Framing ** Approved
06/18/10 Inspector: CG Action: AP APPROVED
Comment: DECK JOISTS AND SLEEPERS PER PLAN
06/23/10 Inspector: ca Action: PI PARTIAL INSPECTION
Comment: SPRIAL STAIR BASE PLATE ON ROOF
Item: 70 BLDG -Misc.
Item: 90 BLDG -Final
07/01/10 Inspector: cg Action: CR CORRECTION REQUIRED
Comment: 1 RETURN 9 ANDRAIL TO SAFETY TERMINAL AT BOTTOM
2 OPEN RISERS MUST BE LESS THAN 4" OPENING
3 3/8" MAXIMUM VARIATION ON RISERS ALLOWED. CHECK BOTTOM RISER
4 ELECTRICAL FINAL REQUIRED
Item: 534 PLAN - FINAL C/O ** Approved **
07/01/10 Inspector: bgibson Action: AP APPROVED
Comment:
REPT131 Run Id: 11745
L1
06 -30 -2010 Inspection Request Re orting Page 31
4:38 pm Vail, CO - City of
Requested Inspect Date: Thursday, July 01, 2010 ~D l O�
Assigned To: BGIBSON
Inspection Type: PLAN
Inspection Area: CG
Site Address: 714 LIONSHEAD PL VAIL
UNIT 683, MARRIOTT
A/P /D Information
Activity: B10 -0124 Type: A -MF Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: IB Insp Area: CG
Owner: ARTINIAN, RON
Contractor: T. HORN ENTERPRISES INC. Phone: (970) 390 -5111
Description: CONSTRUCT ROOF -TOP DECK
Reauested Inspectionls
Item: 534 PLAN -FINAL C/O Requested Time: 08:30 AM
Requestor: T. HORN ENTERPRISES INC. Phone: (970) 390 -5111
Comments: 390 -5111
Assigned To: BGIBSON Entered By: JMONDRAGON K
Action: Time Exp:
4G
c�
Inspection History
Item: 226 FIRE DEPT. NOTIFICATION
Item: 30 BLDG - Framing ** Approved **
06/18/10 Inspector: CG Action: AP APPROVED
Comment: DECK JOISTS AND SLEEPERS PER PLAN
06/23/10 Inspector: cg Action: PI PARTIAL INSPECTION
Comment: SPRIAL STAIR BASE PLATE ON ROOF
Item: 70 BLDG -Misc.
Item: 90 BLDG -Final
Item: 534 PLAN -FINAL C/O