Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E10-0092
TOWN OF Town of Vail Community Development 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Job Address: 1187 HORNSILVER CR VAIL Location.......: Parcel No.....: 210109205001 OWNER SHARER, KEVIN W. THOUSAND OAKS THOUSAND OAKS CA 91320 APPLICANT MARMOT ELECTRIC P.O. BOX 4511 AVON CO 81620 License: 250 -E CONTRACTOR MARMOT ELECTRIC P.O. BOX 4511 AVON CO 81620 License: 250 -E Desciption of Work: Valuation: $12,000.00 05/27/2010 05/27/2010 Phone: 970 - 926 -0990 Permit #...: Project #..: Issued......: 05/27/2010 Phone: 970 - 926 -0990 REPLACE LIGHT FIXTURES Square feet: 500 E10 -0092 PRJ10 -0165 06/03/2010 CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 INSPECTIONS If more than two inspections are performed an additional inspection fee will be applied for each inspection requested /needed. All electrical inspections are performed on Tuesdays and Thursdays. Requests must be received the day before and not later than 4 p.m. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances,and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Ihternattiion "I uilding and Residential Codes and other ordinances of the Town applicable thereto. SIGNATURE: (' Date (Master / homeowner / or non - licensed contractor performing work) PRINTED NAME: M I kG f f i L( --E2 elec_permi 100109 ELECTRICAL PERMIT Electrical Permit Submittal Reguirements Including Heat Tape Installation ❑ Floor plan / Site plan showing proposed work • Building Type • Occupancy Group listed on plans ❑ Load Calculations and one -line diagram when loads or circuits are being added NOTE: For Multi - Family and Commercial buildings —plans and calculations must be prepared by a Colorado Licensed Electrical Engineer Project Street Ad V tl s: � R r- (Number) (Street) (Suite #) Building /Complex Name: Contractor Information: Company: JN' /'o'1" Company Address: A0 2 5m City: Ayln State: w Zip: v Contact Name: Tc) , S Contact Phone: ! 7 U L/� `� U/ ,2 0 E -Mail Town of Vail ntractor egistration No.: " X Con Signature (required) Property Inf j rmation (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Office Use: Project #: M Q ( � Building Permit #: � ✓' Q Q V t o Electrical Permit #: Ev ► ( / — © O Lot #: Block # Subdivision: Define Scope and Location of Work L4 )a.ce �rJ <f e, (use additional sheet if necessary) Includes Temporary Service: ( ) Yes �gNo Work Class: New ( ) Addition ( ) Remodel) Repair ( ) Other ( ) Type of Building: Single - Family Duplex ( ) Multi - Family ( ) Commercial ( ) Restaurant ( ) Other ( ) Owner Name: 5 4FA', A k'`FV /N i,v Date Received: Provide BOTH square footage of area of work AND Valuation 4-, (Labor & Materials) _& Y. Amount of SQ Ft.: J " `- Electrical $: �/w C , co &Yrt cyq 51�,-fe / . MAY 2 6 2010 TOWN OF V/.�I,a7Cr TOWN OF VAIL, COLORADO Statement Statement Number: R100000613 Amount: $193.75 06/03/201012:40 PM Payment Method: Check Init: SAB Notation: 2593 marmot electric ----------------------------------------------------------------------------- Permit No: E10 -0092 Type: ELECTRICAL PERMIT Parcel No: 2101 - 092 - 0500 -1 Site Address: 1187 HORNSILVER CR VAIL Location: Total Fees: $193.75 This Payment: $193.75 Total ALL Pmts: $193.75 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- 00100003111100, GFPO ELEC PERMIT FEES- GFP012 95.00 EP 00100003111100 ELECTRICAL PERMIT FEES 20.00 PF 00100003112300 ELEC PLAN REVIEW 74.75 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 N O N ■ 1c o n' 13 L I G H T I N G LSH14991C — SHALLOW IC HOUSING 4" LOW VOLTAGE HOUSINGS 4 SPECIFICATION 12V Out 37W Max MR 16 12" Ceiling cut -out: 4 112" Application: General purpose recessed downlight housing for low to medium height ceilings for residential and light commercial applications. A variety of trims, compatible styles and finishes are available to achieve the proper d6cor and illumination. Housing: Pre -wired housing adjusts up to a 1 1 14" ceiling thickness. Integral thermal protector to guard against improper lamping and installation. Housing provides an adjustable socket plate wich allows for use of different lamp types. Trim is secured with torsion wing springs. Mounting: Housing suitable for new construction installations only, supplied with (2) 24" adjustable hanger bars with 90 degrees repositioning ability. Hanger bars equipped with nail -less install 3/4" serrated barbed studs and with captive nails, for faster and easier secure mounting in wood joists. Set - screws lock into position and prevent shifting after installation. Earthquake structural cable compatible for drop panel ceiling or any other mounting that requires direct support from structural ceilings. Transformer: Class H insulated magnetic transformer installed adjacent to Junction Box, bottom and top accessible. Thermally protected rated for 90° C Socket: 2 -pin porcelain socket with aluminum heat sink plate. Lamp clips to trim to ensure proper and consistent positioning. Junction Box: 16 gauge pre -wired galvanized steel Junction Box, 25 cubic -inch for a maximum of (8) #12 AWG wires. Furnished with (5) 3/4 ", (1) 1" and (4) Romex knock -outs. Strain clamps to install or remove covers for easy access and ground wire. Equipped with safety standard fitting for flex- conduit. Insulation Contact: IC rated housing rated for direct contact with low to medium density loosefill blown and rolled insulation. For use with high density loosefill blown insulation, reduce rated lamp wattage accordingly (roughly %15 - %20). Airflow: Airtight option is designed to restrict air flow from room into plenums in compliance to the WSEC - Washington State Energy Code, (Less than 2.0 CFM -Cubic Feet per Minute). Complies to Title24 air flow requirements (Air- tight). Safety Labels: ETL/CETL listed for through- branch wiring (8) No. 12 AWG 90 °C and suitable for damp locations. NYC approved: Calendar #41937. ORDERING LSHI4991C A :IC Airtight Blank:37W AE :IC Airtight Electronic Tel: 323.904.0200 �J J s 0 7 5/8 5 Blank: 120V -27 :277V Please see website for more compatible items. Note: Wattage limitations on compatible items must be met. ORDERING EXAMPLE : LSH 1 4991CAE-27 Product specifications subject to change without notice. CLEAR LENSED REFLECTOR BAFFLE W / CLEAR LENS ADJUSTABLE GIMBAL � � s REFLECTOR FROSTED GLASS DOME SHOWER DECO GLASS (FROSTED RING) DECO SHIELD REFLECTOR DECO SHIELD BAFFLE ADJUSTABLE SPOT REGRESSED EYEBALL PINHOLE W/ BAFFLE NARROW APERTURE REFLECTOR i WALL WASH REFLECTOR EYELID DECO GLASS PANEL PINHOLE WI REFLECTOR Please see website for more compatible items. Note: Wattage limitations on compatible items must be met. ORDERING EXAMPLE : LSH 1 4991CAE-27 Product specifications subject to change without notice. From:Marmot Electric Inc. 970 524 0991 06/02/2010 15:28 #279 P.001 /002 MARMOT ELECTRIC INC PO Box 4511 Avon Co 81620 FAX To: Matt From:;` Fax: Pages: 2 Phone: Date: 6 -2 -10 Re: cc: Comments: Matt, Due to the 2009 efficiency codes we ore specifying LED MR 16's in the renovation at the Hornsilver residence. Please find the attached specification sheet for said lumping regards John Cummins Marmot Electric Inc From:Marmot Electric Inc. 970 524 0991 06/02/2010 15:28 #279 P.002 /002 Patented ILIAV Technology Standard MR16 Fits most Industry Standard MR16 Lamp replacement Lamp Holders Low Maintenance LED Life Span 50,000 to 100,000 Hours Various Beam 20, 30, 45 and 60 degrees Spreads Aluminum Housing — Sturdy, durable construction, Recyclable, LED operates cooler LED Lamp Technology — Super Bright, High Lumen Output. Environmentally Safe, no Mercury, no Lead, no UV or IR Radiation. 30 -70% Less Energy Usage HOUSING: LED Lamp Tube housings are die -cast i 140 aluminum. Accommodate all existing I i:o MR16 lamp applications. 100 ELECTRICAL: Bo LED Diodes are high intensity. 60 1.5W LED = 35W MR16 . 3.OW LED = SOW MR16 20 MOUNTING: O LED MR16 Lamp adapter fits all respective MR16 lamp holders. LED 3 MR16 30 CW MR16 Foot Candle Comparison Chart* 'Actual measurements @ 3R- 4615 State St. Montclair, CA. 1!. _ _L _k\ ph 909.627.1600 fax 909.627.2887 LED L5 -1007 Lunen- Statr8 7W M1116 LURM -StWI M MIg6 Coventiantl MR16 SOW CW wW W LED: LED Lamp Number of LED Lamps 20 WW: 3000K 1 LED - 1.5W 30 CW :4100K 3 LEDs - 3.OW 45 DL : 6000K 60 I 08 -24 -2010 Inspection Request Reporting Page 57 7:49 am Vim, CO - CitV Of Requested Inspect Date: Tuesday, August 24, 2010 Assigned To: MDENNEY Inspection Type: ELEC Site Address: 1187 HORNSILVER CR VAIL A/P /D Information Activity: E10 -0092 Type: B -ELEC Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: SHARER, KEVIN W. Contractor: MARMOT ELECTRIC Phone: 970 - 926 -0990 Description: REPLACE LIGHT FIXTURES Requested Inspection(s) Item: 190 ELEC -Final Requested Time: 08:30 AM Requestor: Phone: Comments: 970 - 904 -0125 Assigned To: MDENNEY Entered By: MHAEBERLE K Action: Time Exp: Inspection History Item: 120 ELEC -Rough *" Approved *" 06/08/10 Inspector: mdenney Action: AP APPROVED Comment: Item: 190 ELEC -Final REPT131 Run Id: 11843