Loading...
HomeMy WebLinkAboutDRB100201Design Review Board ACTION FORM TOWN C0hV69JN Y DEVELOPMENT Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel :970.479.2139 fax: 970.479.2452 web: www.vailgov.com Project Name: FIRE STATION 3 Project Description: Participants: DRB Number: DRB100201 CHANGES TO APPROVED PLANS: CHANGE RETAINING WALL MATERIAL TO MESA ASHFORD RETAINING WALL SYSTEM ASHLAR FACING OWNER TOWN OF VAIL 06/08/2010 75 S FRONTAGE RD VAIL CO 81657 APPLICANT TOWN OF VAIL 06/08/2010 MARK MILLER, FIRE CHIEF 75 S FRONTAGE RD VAIL CO 81657 Project Address: 2399 N FRONTAGE RD W VAIL Location: FIRE STATION 3 Legal Description: Lot: Block: Subdivision: VAIL DAS SCHONE FIL 1 Parcel Number: 2103 -114- 1501 -9 Comments: BOARD /STAFF ACTION Motion By: GILLETTE Action: APPROVED Second By: UESBO Vote: 4 -0 -0 Date of Approval: 06/16/2010 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and /or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12 -3 -3: APPEALS. Cond:202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner: Bill Gibson DRB Fee Paid: $0.00 Application for Design Review Changes to Approved Plans General Information: This application is for all changes to approved plans prior to Cert 6 � v 4; plication for Design Review cannot be accepted until all required information is received by the Community Development Department. Design review approval expires one year from the date of approval, unless a building permit is issued and construction commences. Submittal Requirements: 1. Three (3) Copies of all pertinent approved plans with illustrated, labeled changes 2. Joint Property Owner Written Approval Letter, if applicable Fee: $20 Single Family Duplex Multi- Family ✓ Commercial Description of the Request: Change retaining wall m to Mesa As hford R Wall System Ashlar Facing Physical Address: 2399 North F r o nt ag e Road West Parcel Number: 21 03 1 1 4 15019 (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.) Property Owner: Town of Vail Mailing Address: 75 South Frontage Road, Va il, CO 81657 Owner's Signature: Phone: 477 -3474 Primary Contact/ Owner Representative: Mark Mil ler, Fire Chief Mailing Address: same E -Mail: mmiller @vailgov.com Fax: Phone: same For Office Use Only: Cash_ CC: Visa / MC Last 4 CC # Auth # Check # Fee Paid: a v Received From: Meeting D ad. _ 6 - &41 10 DRB No.: 12 91 10 0 PD ) Planner: Project No: D/dg -- aoe I Zoning: Land Use: Location of the Proposal: Lot: Block: Subdivision: FarW A 'R C,%A T60 C+ V WL I DOS SGVIOKQ I01-Jan-10 Architecture Re: Vail Fire and Emergency Services Station 93 Vail, Colorado P r a n n i n g Proposed MSE Retaining Wall Revision BWG Project No. 09083 Interiors The general contractor is requesting a substitution to the approved MSE retaining wall product. Approved Product: The Keystone Century Wall - Vail Blend product was previously presented to DRB. An example of the appearance of the product is included on the next page and in the attached brochure. This product is composed of three different block sizes to obtain the installed pattern and has more of a rough hewn look. An actual installed example in the product in the Vail Blend color can be viewed at the new snowcat access road at 890 S. Frontage Road West. Proposed Product: The Mesa Ashford product is the proposed alternate to the Keystone product. An example of the appearance and color is included on the next page and a brochure is attached. This product would be composed of three different size block to obtain the installed pattern and has more of an dressed stone (ashlar) look. One exception to the brochure and the mock up is that the vertical unit would be cut in half to provide an 8" x 6" unit resulting in a pattern matching the pattern of the approved product above. A mock up of the product is available for viewing at the north side of the fire station site. u c ,u '2 o. ' 2 a+ ° DRB Memo m 0 June 8, 2010 Architecture Re: Vail Fire and Emergency Services Station 93 Vail, Colorado P r a n n i n g Proposed MSE Retaining Wall Revision BWG Project No. 09083 Interiors The general contractor is requesting a substitution to the approved MSE retaining wall product. Approved Product: The Keystone Century Wall - Vail Blend product was previously presented to DRB. An example of the appearance of the product is included on the next page and in the attached brochure. This product is composed of three different block sizes to obtain the installed pattern and has more of a rough hewn look. An actual installed example in the product in the Vail Blend color can be viewed at the new snowcat access road at 890 S. Frontage Road West. Proposed Product: The Mesa Ashford product is the proposed alternate to the Keystone product. An example of the appearance and color is included on the next page and a brochure is attached. This product would be composed of three different size block to obtain the installed pattern and has more of an dressed stone (ashlar) look. One exception to the brochure and the mock up is that the vertical unit would be cut in half to provide an 8" x 6" unit resulting in a pattern matching the pattern of the approved product above. A mock up of the product is available for viewing at the north side of the fire station site. F r s A.. r - as � _ ~• � ,may � — Wa jP ? ' .�9F r ""•'�. e _ v Previously presented and approved MSE wall material (Keystone Century Wall) Proposed substitute MSE wall (Mesa Ashford) I N 0 , Introducing r 4 I-IF 5 e M . 4 C i - f � d' The 4" Keystone Half Century Wall" can be easily combined with 8" Keystone Century Wall units for almost any application. The photograph above beautifully illustrates this design combination. 1 Note: Keystone Half Century Wall availability varies by region. Contact your local Keystone sales representative for more information. KE'(STO N E. Centur3waR,) Crafted specifically for taller wall structures and heavy -load- ing conditions, Keystone Century Wall' offers the distinctive appearance and character of a random - pattern, natural stone wall with the structural integrity, performance, and the envi- ronmental friendliness of concrete. Three different -sized Keystone Century Wall units give the appearance of classic, hand - crafted stone, yet make it fast and almost effortless to create visually stunning and heavy -duty wall structures. The Keystone Century Wall is perfect for residential, commercial, industrial, and institu- tional applications. Keystone Century Wall is also easy to install and utilizes a unique, patented fiberglass pin connection method for added structural integrity and performance. The open -core design of the Keystone Century Wall units allow for additional facial stability and interlocking capacity. In large -scale and tall wall applications, Keystone Century Wall offers the design freedom to create curves, 9o° corners, battered and near -ver- tical walls, terraces, and more. Keystone Century Wall is the ultimate wall system to handle the big jobs with beauty and brawn. Offering a quaint, old - world appearance while providing superior strength, Keystone Century Walls can rise to great heights with appro- priate engineering.* *For walls over 3 feet in height, soil reinforcement is generally necessary. A qualified engineer should be consulted for design and analysis of structures. RETAINING EXCELLENCE Features &Benefits PATENTED PIN SYSTEM . The Keystone Century Wall uses high- strength fiberglass pins for shear resistance, alignment, and geogrid connection. VARIOUS ALIGNMENT OPTIONS • All units (excluding caps) have the option of a near vertical set back. CHARACTER & STRENGTH • These rugged and random -sized high- strength concrete modules have the color and texture of natural stone. • Larger unit dimensions are the appropriate scale for tall wall construction. FIBERGLASS PINS Keystone Century Wall uses high- strength fiberglass pins with "shouldered" caps. 13­ <i 5 - 1 /4" (130mm) total length 1 - 1 /4" (32mm) shoulder length 1 12" (13mm) diameter at pin shaft 3/4" (20mm) diameter at shoulder ASTM 4475-85 short beam shear= 6,400 psi (44 kPa) 90 CORNER UNITS LEFT & RIGHT) • Corner units have both "near vertical" and setback (8.8 setback positions. • Corner units can be used as wall units with either the 16" or 12" face exposed to add a larger percentage of longer units to the exposed face area composition • Corner units can be placed on end (vertical) to create a 16" high jumper unit between (2) 8" high wall courses. Some field adjustment may be required on the textured 90° end to rest squarely on the course below. CURVES A. COMMON RADIUS (with unit tail extensions left in place) = 23' -6" B. MINIMUM RADIUS (with unit tail extensions removed on site) = 4' -6" NOTE: each individual unit or any series of units in random order will build to the same common radius positions "A" or minimum radius " BOTTOM VIEW OF LARGE UNIT F P IN RECEIVING CHANNEL * Product colors may vary from those shown in this brochure. Unit availability, dimensions, weight, and color may vary by region. LARGE UNIT 93 lbs. (42 1(g) 8 "h x 12 "d x 18 "w* (2o0mm x 300mm x 450mm) MEDIUM UNIT 58 lbs. (26 kg) 8 "h X 12 "d x 11 "W ' >fE r (200mm x 300mm x 28omm) SMALL UNIT 37 lbs. (17 1(g) 8 "h x 12 "d x 7 "w* (200mm x 300mm x 28omm) 90 CORNER UNIT (two sides textured) Corner units provided in left /right sets 78 lbs. (35 kg) 8 "h x 12 "d x 16 "w* (200mm x 300mm x 400mm) Note: Check with local representative for unit availability. CAP UNIT (two sides textured) 30 lbs. (14 kg) i 4 "h x 12 "d x 14 " /8 "w* (200mm x 300mm x 355mm /200mm) 9 RETAINING EXCELLENCE Grander Scale... �n z r` a J Hi s . -ar X 1' 7 tdi�.'Y , !►171 i Lw �pg 1 � r+ -. �1 i RETAINING EXCELLENCE MESA ASHFORUm RETAINING WALL SYSTEM • • • • • The Random, Natural Look for Mesa® Walls Ashlar Facing with the Ashford TI Wall System Obtaining a natural- inspired ashlar finish for your retaining wall project is easy when you follow one of the three patterns developed for use with the Ashford Retaining Wall. The examples below are three of an infinite number of options that can be developed with the Ashford Units. The Mesa Ashford Wall's unique top and bottom channel and positive, mechanical connection allow the flexibility to design almost any look desired. However, P r� P, the best patterns for constructability are designed in two foot vertical sections and have a repeating pattern as shown below. These units are available in the same colors, blends and textures as other Mesa Units. They can even be antiqued for a beautiful weathered look with minimal product waste. Walls can be built to a near - vertical facing angle, or they can be installed to create 90° corners, stairs and dramatic serpentine curves. The Different Mesa Ashford Units The Mesa Ashford System's veneer is made up of three unique, high- compressive strength, dry-cast concrete blocks. Each unit has slots to lock the patented Mesa Connector to the Tensar° Structural Geogrids with the block face. This gives the highest quality, block -to- geogrid connection and assures long -term serviceability. w� Tall Unit: 16 "h x 6 "w x 1T'd nom. 60 lbs. ape . Medium Unit: 8 "h x 12 "w x 11 d nom. 60 lbs. Standard Unit: 8 "h x 18 "w x 11" d nom. 75 lbs. PATTERN SQUARE STANDARD MEDIUM VERTIG FOOTAGE UNIT UNIT UNIT 2 -1 -2 4 2 1 2 6 -7 -2 12 6 7 2 6 -7 -5 14 6 7 5 From the table above, you can determine the block quantities needed for your project based on one of three pre- designed face patterns. For example, a project requiring 1,000 square feet of wall constructed with pattern 6 -7 -2 would be calculated as follows: Step 1: Determine the required units to complete the project by dividing the total project square footage by the pattern square footage. In this case: 1000 / 12 = 83.3 The Mesa Systems Advantage Step 2: Use the results from Step 1 to multiply each unit required for the pattern. For this example: 83.3 x 6 = 500 standard units 83.3 x 7 = 584 medium units 83.3 x 2 =167 vertical units NOTE: Always round to the next whole number when calculating block quantities. Mesa Retaining Wall Systems provide superior, attractive and cost - effective solutions for all your retaining wall needs. They combine the economy and versatility of segmental concrete units with proven geogrid technology to create the new standard in structural wall systems. The only single- source, fully integrated SRW system, the Mesa Systems are designed and detailed to provide optimum efficiency and long -term performance. With their positive mechanical connection, full load transfer is assured from wall face to reinforcement for unsurpassed structural reliability. Easy to handle and install, the Mesa Systems are also low maintenance as well. Blocks are locally available in a wide variety of styles, colors and textures. For more information, call 800 - TENSAR -1. Tensar International Corporation 5883 Glenridge Drive, Suite 200 Atlanta, Georgia 30328 T ensar 800 - TENSAR -1 INTERNATIONAL www•tensar- international.com 02007, Tensar International Corporation, Limited LLC, Inc. Certain products and /or applications described or illustrated herein are protected under one or more U.S. patents. Other U.S. patents are pending, and certain foreign patents and patent applications may also exist. Trademark rights also apply as indicated herein. Final determination of the suitability of any information or material for the use contemplated, and its manner of use, is the sole responsibility of the user. Printed in the U.S.A. MESA_ FLY_ASH_1.07