EXECUTIVE SUMMARY
Sunrise Environmental, Inc. (SEI) provided air monitoring services for Reliance Environmental
Services, LLC (RES) at The Landmark Unit 701, located at 610 Lionshead Circle, Vail,
Colorado on May 23, 2010. The field representative for SEI was Mr. Scott D. Sanders. Work
was performed in conjunction with asbestos abatement at the site. Asbestos abatement was
conducted by Reliance Environmental Services, LLC; a Colorado Department of Health licensed
asbestos abatement contractor.
SEI’s scope of work included collection and analysis of final clearance air samples, performing
visual inspections of work areas prior to collection of air samples, and assembling project
documentation.
Subsequent to cleanup, SEI visually inspected the containment areas for visible dust and debris.
Upon passage of visual inspection, SEI collected final clearance air samples and notified
Reliance Environmental Services, LLC when laboratory results indicated airborne fiber
concentrations were not in excess of 0.01f/cc as required by Colorado Department of Public
Health and Environment (CDPHE), Regulation 8.
At project completion, air-monitoring results indicate concentrations of airborne fibers did not
exceed 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for re-
occupancy following asbestos abatement.
CLIENT: Reliance Environmental Services, LLC.
20274 E. Union Drive
Aurora, Colorado 80015
PROJECT
LOCATION: The Landmark, Unit 701
610 Lionshead Circle
Vail, Colorado
DESCRIPTION
OF WORK: Final Clearance Air Monitoring
ASBESTOS
ABATEMENT
CONTRACTORS: Reliance Environmental Services, LLC.
SUNRISE
ENVIRONMENTAL INC.
REPRESENTATIVE: Mr. Scott D. Sanders
INTRODUCTION
SEI provided air monitoring services for Reliance Environmental Services, LLC at The
Landmark, Unit 701, located at 610 Lionshead Circle, Vail, Colorado on May 23, 2010. The
field representative for SEI was Mr. Scott D. Sanders. Work was performed in conjunction with
the removal of asbestos containing ceiling texture at the site. Asbestos abatement was conducted
by Reliance Environmental Services, LLC; a Colorado Department of Public Health and
Environment (CDPHE) licensed asbestos abatement contractor.
SEI performed the final visual inspection, and the collection and analysis of Phase Contrast
Microscopy (PCM) air samples after asbestos abatement. SEI successfully participates in the
AIHA Proficiency Analytical Testing (PAT) Program (Laboratory ID# 196102) and participates
in inter-laboratory and intra-laboratory round robin analysis. All SEI analysts have been
certified in NIOSH 582E to perform collection and analysis of PCM air samples.
SCOPE OF WORK
Reliance Environmental Services, LLC’s scope of work for this project consisted of the
removal/disposal of asbestos containing ceiling texture from Unit 701.
SEI has performed the following Industrial Hygiene services:
• Performed visual inspections of the abatement areas,
• Collection and analysis of PCM air samples to monitor concentrations of airborne
fibers after asbestos abatement in accordance with CDPHE Regulation No. 8,
• Assembled and submitted project documentation.
The findings set forth in this report are strictly limited in time and scope to the date of the
evaluation. The conclusions presented in the Report are based solely on the services described
therein, and not on scientific tasks or procedures beyond the scope of agreed upon services. SEI
performed a visual inspection and collected final clearance air samples following the removal of
accessible areas of asbestos containing ceiling texture in Unit 701. Suspect asbestos containing
materials not included in the abatement scope of work may still be remaining in the unit,
including but not limited to: asbestos containing drywall joint compound or drywall texture.
PROJECT DESCRIPTION
Sequence of field work: Table 1 summarizes the field work in the order in which it was
completed.
Table 1. Summary of Field Work
DATE FIELD WORK
05-23-10 Pre-clearance visual inspection of Unit 701 containment.
(RES, SEI)
Collection and analysis of five (5) PCM final clearance air samples. (SEI)
PCM clearance samples below 0.01f/cc. RES on-site supervisor is
notified. (SEI)
Containment is torn down. (RES)
AIR MONITORING
Sample Collection
The effective filter area for samples collected on May 23, 2010 was 385mm2.
PCM samples were collected on 25 millimeter (mm) mixed cellulose ester membrane filters (0.8
micron pore size). The filters were preassembled by the manufacturer in conductive three stage
cassettes with extension cowls.
Air samples were collected at a flow rate of 14.8 to 15.0 liters per minute (LPM). Flow rates
were recorded at the beginning and at the end of the sampling period using a DryCal Primary
Standard flow calibrator. All air samples were collected open-faced and positioned at breathing
zone height (approximately five feet above the floor) with exposed portion of the cassette facing
downward. Clearance air samples were collected aggressively and in accordance with CDPHE
Regulation #8. (See Appendix A for sample data)
PCM Analysis Methodology
PCM samples were analyzed by SEI according to the NIOSH 7400 Method (“A” counting rules).
This method can be found in the NIOSH Manual of Analytical Methods. All air sample results
are calculated with blank corrections, checked and reviewed. Unused portions of samples are
archived three months unless client requests special handling. Laboratory analysis was
accomplished utilizing a Phase Contrast Microscope. Size and fiber counts were performed at
400X magnification. The microscopy field area (MFA), defined by the Walton-Beckett
Graticule is 0.00785mm2.
Report Data Key
Fbrs/Flds: Fibers per fields; total fibers counted over total areas examined.
LOD: Limit of Detection; the calculated lower limit of detection expressed in fibers per
cubic centimeter. Based on limit of detection of (5.5/100 fibers/field).
F/cc: Fibers per cubic centimeter.
<LOD: Less than the limit of Detection; thus, the analytical result is less than the value
indicated in the LOD column.
CONCLUSIONS
At project completion, air-monitoring data indicate concentrations of airborne fibers were not in
excess of 0.01f/cc as required by the Environmental Protection Agency (EPA) and CDPHE for
re-occupancy following asbestos abatement.
Reviewed and signed for the company by:
_________________________________
Scott D. Sanders
President
APPENDIX A
PCM AIR SAMPLE DATA
SUNRISE ENVIRONMENTAL, Inc.
Phase Contrast Microscopy Sampling Data Sheet
PROJECT
DATE: May 23, 2010
PROJECT
NUMBER: SEI10-P049
CLIENT: Reliance Environmental Services, LLC.
20274 E. Union Drive
Aurora, Colorado 80015
PROJECT
ADDRESS: The Landmark Unit 701, 610 Lionshead Circle, Vail, Colorado
Sample (Time) Total (Flow Rate (l/min) Total Fibers/
Number Start Stop Minutes Start Stop Avg. Volume Field LOD Fibers/cc
0523-01 --- --- --- --- --- --- --- 1/100 --- ---
0523-02 --- --- --- --- --- --- --- 0/100 --- ---
0523-03 2058 2248 110 15.0 14.6 14.8 1628. 7/100 .002 0.002
0523-04 2058 2248 110 15.0 15.0 15.0 1650. 6/100 .002 0.002
0523-05 2059 2249 110 15.0 15.0 15.0 1650. 8.5/100 .002 0.002
0523-06 2059 2249 110 15.0 15.0 15.0 1650. 8/100 .002 0.002
0523-07 2100 2250 110 15.0 15.0 15.0 1650. 7.5/100 .002 0.002
Sample Sample
Number Type Location/Description Results
0523-01 Field Blank 1/100
0523-02 Field Blank 0/100
0523-03 CLEARANCE Unit 701, kitchen 0.002
0523-04 CLEARANCE Unit 701, living room 0.002
0523-05 CLEARANCE Unit 701, northwest bedroom 0.002
0523-06 CLEARANCE Unit 701, northeast bedroom 0.002
0523-07 CLEARANCE Unit 701, loft 0.002
LOD= Limit of Detection