Loading...
HomeMy WebLinkAboutFairmont Letter 101408 75 South Frontage Rd. Department of Community Development Vail, Colorado 81657 970-479-2138/479-2139 FAX 970-479-2452 October 14, 2008 David Louie Sent via email to Dlouie@sb-architects.com TJ Brink Sent via email to Tbrink@semperdev.com Adam Williams Sent via email to Awilliams@arcipm.com Re: Fairmont Vail PEC Final Review Submittal Dear David, TJ and Adam, I am writing to provide a summary of comments from Town of Vail Departments as well as a summary of requirements for your PEC submittal for the November 10, 2008 meeting. Building Department: I clarified with Martin Haeberle, Chief Building Official, who confirmed that you will have to pick between the 2003 and the 2009 ICC. Martin is happy to discuss this further. Public Works: Provide a response to all comments provided by Tom Kassmel at our last meeting. The loading and delivery bay will need to accommodate a WB50. Please depict this on the plans. Be mindful of garage door height and grade changes at garage entry. CDOT approval- Tom confirmed that a preliminary meeting where CDOT gives a conceptual approval of the Frontage Road grading and access will be sufficient prior to PEC final approval. However, a condition of the PEC approval will be to get final approval from CDOT. Fire Department: Provide fire staging and egress on a separate site plan to clearly identify where staging and egress will occur and how fire trucks can be accommodated. Need to provide access from fire command center to fire staging. If you would like to discuss this further, please contact Mike McGee as soon as possible. Planning: A conditional use permit application needs to be submitted. In anticipation of this application, the project was noticed to the public as a major exterior alteration, as well as a conditional use permit for dwelling units, accommodation units, employee housing units, conference facilities and meeting rooms on the basement level, multi-family dwelling units on the first floor, and an eating and drinking establishment on the second floor. If the conditional use permit includes any conditional uses other than those listed above, we will need to renotice the item, and you will need to submit self-addressed stamped envelopes to send notice to adjacent property owners. Please note the requirements for parking, with doubled parked/ valet spaces at a maximum of 50% of the required parking, and compact spaces at a maximum of 25% of parking. Also note that enclosed parking spaces have a minimum size of 8 feet x 18 feet, while you are showing bigger spaces as part of your plan. Ensure that all plans have clearly labeled items and no internal coding that will be unrecognizable by Town Staff (i.e. S1- is this stairs?) PEC Submittal Requirements: In addition to addressing any applicable comments above, please submit the following items for review by Town Staff and the PEC by October 27, 2008. Conditional Use Permit application, and SASE envelopes for adjacent properties, if applicable Letter from TJ Brink confirming that no HOA approval is necessary, since he has the rights to development, and as such, approves the project A written statement describing the proposal and how the proposal complies with the applicable adopted master plans and planning documents, including: Employee Housing Analysis: Existing and proposed square footage of dwelling units and each individual commercial use Parking analysis: Provide data on how the project complies with TOV parking requirements Summary of zoning requirements and how the project meets these requirements. I have attached a zone check sheet that will help you in this summary. Photo overlays and/or other graphic material to demonstrate the special relationship of the proposed development to adjacent properties, specifically VVMC, and to public spaces Utility companies’ sign-off for the project Four sets of full size plans and ten sets of 11x17 plans, including the following (for detailed requirements, see section 6 of this letter): Stamped Topographic Survey Existing and Proposed Site and Grading Plans including details on pedestrian an vehicular access, with a separate site plan showing fire staging and egress Landscape Plan showing proposed landscaping (including trees to be removed), with hardscape and softscape color coded and labeled with square footage of each section. Note that landscape areas must be 300 sq feet or more to count as part of landscaping. If there are any retaining walls, note the elevation at bottom and top of the walls. If any walls are greater than 3 ft tall (with a 6 foot max for all walls) the wall details need to be stamped by a Colorado Licensed Professional Engineer Roof Height Plan showing ridge and peak elevations and natural or interpolated grade below ridges and peaks, as well as average height calculations Roof Plan showing areas of flat roof shaded and percentage of flat and sloped roof noted on plans Existing and Proposed Architectural Elevations including dimensions of sections of materials on the façade. Provide a color-coded copy of combustible materials for the Fire Department Sun/shade analysis of the existing and proposed building for the spring/fall equinox and winter solstice at 10:00 am and 2:00 pm Existing and Proposed Architectural Floor Plans including clearly labeled dwelling units, accommodation units, employee housing units, and individually labeled commercial space with square footage for each individual unit or use A 3D model of the project and adjacent buildings, to be submitted electronically A physical model of the proposed development to include buildings and major site improvements on adjacent properties will be required at the PEC meeting. Detailed Submittal Requirements: The following outlines detailed information to include on each sheet of plans: Topographic survey: Wet stamp and signature of a licensed surveyor Date of survey North arrow and graphic bar scale Scale of 1”=10’ or 1”=20’) Legal description and physical address Lot size and buildable area (buildable area excludes red hazard avalanche, slopes greater than 40%, and floodplain) Ties to existing benchmark, either USGS landmark or sewer invert. This information must be clearly stated on the survey Property boundaries to the nearest hundredth (.01) of a foot accuracy. Distances and bearings and a basis of bearing must be shown. Show existing pins or monuments found and their relationship to the established corner. Show right of way and property lines; including bearings, distances and curve information. Indicate all easements identified on the subdivision plat and recorded against the property as indicated in the title report. List any easement restrictions. Spot Elevations at the edge of asphalt, along the street frontage of the property at twenty-five foot intervals (25'), and a minimum of one spot elevations on either side of the lot. Topographic conditions at two foot contour intervals Existing trees or groups of trees having trunks with diameters of 4" or more, as measured from a point one foot above grade. Rock outcroppings and other significant natural features (large boulders, intermittent streams, etc.). All existing improvements (including foundation walls, roof overhangs, building overhangs, etc.). Environmental Hazards (ie. rockfall, debris flow, avalanche, wetlands, floodplain, soils) Watercourse setbacks, if applicable (show centerline and edge of stream or creek in addition to the required stream or creak setback) Show all utility meter locations, including any pedestals on site or in the right-of-way adjacent to the site. Exact location of existing utility sources and proposed service lines from their source to the structure. Utilities to include: Cable TV, Sewer, Gas, Telephone, Water, Electric Size and type of drainage culverts, swales, etc. Adjacent roadways labeled and edge of asphalt for both sides of the roadway shown for a minimum of 250’ in either direction from property. Site and Grading Plan: Scale of 1”=20’ or larger Property and setback lines Existing and proposed easements Existing and proposed grades Existing and proposed layout of buildings and other structures including decks, patios, fences and walls. Indicate the foundation with a dashed line and the roof edge with a solid line. All proposed roof ridge lines with proposed ridge elevations. Indicate existing and proposed grades shown underneath all roof lines. This will be used to calculate building height. Proposed driveways, including percent slope and spot elevations at the property line, garage slab and as necessary along the centerline of the driveway to accurately reflect grade. A 4' wide unheated concrete pan at the edge of asphalt for driveways that exit the street in an uphill direction. Locations of all utilities including existing sources and proposed service lines from sources to the structures. Proposed surface drainage on and off-site. Location of landscaped areas. Location of limits of disturbance fencing Location of all required parking spaces Snow storage areas. Proposed dumpster location and detail of dumpster enclosure. Retaining walls with proposed elevations at top and bottom of walls. A detailed cross-section and elevation drawings shall be provided on the plan or separate sheet. Stamped engineering drawings are required for walls between 4’ and 6’ feet in height. Delineate areas to be phased and appropriate timing, if applicable Landscape Plan: Scale of 1" = 20' or larger Landscape plan must be drawn at the same scale as the site plan. Location of existing trees, 4" diameter or larger. Indicate trees to remain, to be relocated (including new location), and to be removed. Large stands of trees may be shown (as bubble) if the strand is not being affected by the proposed improvements and grading. Indicate all existing ground cover and shrubs. Detailed legend, listing the type and size (caliper for deciduous trees, height for conifers, gallon size for shrubs and height for foundation shrubs) of all the existing and proposed plant material including ground cover. Delineate critical root zones for existing trees in close proximity to site grading and construction. Indicate the location of all proposed plantings. The location and type of existing and proposed watering systems to be employed in caring for plant material following its installation. Existing and proposed contour lines. Retaining walls shall be included with the top of wall and the bottom of wall elevations noted. Architectural Floor Plans: Scale of 1/8" = 1' or larger; 1/4" is preferred Floor plans of the proposed development drawn to scale and fully dimensioned. Floor plans and building elevations must be drawn at the same scale. Clearly indicate on the floor plans the inside face of the exterior structural walls of the building. Label floor plans to indicate the proposed floor area use (i.e. bedroom, kitchen, etc.). One set of floor plans must be "red-lined" indicating how the gross residential floor area (GRFA) was calculated. See Title 12, Chapter 15 – Gross Residential Floor Area for regulations. Provide dimensions of all roof eaves and overhangs. Architectural Elevations: Scale of 1/8" = 1' or larger; 1/4" is preferred All elevations of the proposed development drawn to scale and fully dimensioned. The elevation drawings must show both existing and finished grades. Floor plans and building elevations must be drawn at the same scale. If building faces are proposed at angles not represented well on the normal building elevations, show these faces also. Elevations shall show proposed finished elevation of floors and roofs on all levels. All exterior materials and colors shall be specified on the elevations. The following shall be shown graphically and fully dimensioned: fascia, trim, railings, chimney caps, meter locations, and window details. Show all proposed exterior lighting fixtures on the building. Illustrate all decks, porches and balconies. Indicate the roof and building drainage system (i.e. gutters and downspouts). Indicate all rooftop mechanical systems and all other roof structures, if applicable. Illustrate proposed building height elevation on roof lines and ridges. These elevations should coordinate with the finished floor elevations and the datum used for the survey. Exterior color and materials, either on the elevations, or on a separate sample board Should you have questions, feel free to call or email. I will need to have all information submitted by Monday, October 27, 2008 at 5pm in order to have this item heard on the November 10, 2008 PEC meeting. If additional noticing is required for the conditional use permit, please inform me of such by Thursday October 23, 2008. Best, Rachel Friede, AICP Planner II (970)479-2440 Rfriede@vailgov.com