HomeMy WebLinkAboutB10-0129 comment letterDepartment of Community Development
5 South Frontage Road
Vail, Colorado 81657
970-479-2138
FAX 970-479-2452
www.vailgov.com
______________________________________________________________________
PROJECT REVIEW COMMENTS
DATE: 6/11/10
TO: Geyer Construction
pgeyerconstruction@gmail.com
PERMIT APPLICATION #: B10-0129
PROJECT ADDRESS: 610 W Lionshead #701
OCCUPANCY GROUP: R2
TYPE OF CONSTRUCTION: IB
NUMBER OF STORIES: existing
BUILDING AREA: existing
● Submit two complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified.
● Please respond in writing to each comment with a response letter addressing each comment.
BUILDING DEPARTMENT COMMENTS
Architectural Comments:
1 Indicate building construction type per IBC ch. 6 on the plans. Town of Vail records indicate IB construction type for the Landmark building
2 Indicate on plans all new framing to be non-combustible construction. Include wall and ceiling construction details. IBC 602.2
3 Revise loft guard height to 42” minimum per IBC 1013
4 Revise 6.1 wood framing notes on the plan sheets. Wood framing is not permitted in type IB construction.
5 Show stairway construction with non-combustible framing per IBC 1009.6
Structural Comments:
6 Clarify scope of structural work, include structural sheets in the plan sets