HomeMy WebLinkAboutE10-0130 SET RE�EIPT
R�CEIPT I�UM�ER: R14U�447ZU
SET ZD: 5����Q�235 SET NAME: Temp set of Type AGTIVITY
TR.A,NSA�T�C]N DATE: 4612212�1� T�TAL PAYMENT: 4.4 5 6.2 5
T�TAL PAID FRQM TRL]ST: .�4
T4TAL PAID FR�M CURRENCY: 4,4 5 5.�5
SET TRANSACTI�NS:
S�t Memb�r Amount
E14-Q1�9 193 .75
E10�-Q11� 193 .75
Elfl-�111 193 .75
El�-0112 193 .75
E10-D113 193 .75
E10-�114 193 .75
Eln-D�15 193 .75
E14-�116 193 .75
El�-�117 193 .75
E1Q-Q118 193 ,75
Ela--�119 193 .75
E10-Ql�Q 193 .75
E14-�121 193 ,75
El�-�1�2 193 .75
E1�-0123 193 .75
El�-�124 193 .75
E10-�125 193 .75
ElQ-Q126 193 .75
E1�-0127 193 .75
El�-�128 193 .75 .
E1�-�129 193.75
E1Q-Q130 193 .75
ElQ-�131 193 .75
TQTAL: 193.T5
TRAN SACTI�N LI ST:
Type Method D�scriptian Am�unt
Payment Check �20D 4.45��.25
TC�TAL: 4.4 5 5.�5
AC��UNT ITEM LIST:
Description Account Cad� Current Pmts
ELEC PERMIT FEES-GFPOl2 OO1DD�0311110Q, 2, 185.D�
ELE� PLAN REVIEG�T PF �01�0��31123� 1, 719.25
ELEC'�'RICAL FER�IIT F'EES EP 0�14DD�31111.4 46�,�fl
WZLL CALI., INSPECTION FEE WC OQl�Q0�311�8fl 92.�D
TQTAL: 4.455.2�
RECEIPT ISSUED BY: LCAMPBELL INITIALS: JLE
ENTERED DATE: U51�21Z01� TrME: 11:37 AM
s
� �
���'���` Town of Va�l Community Q��el�pment
7� South Frontage Road, Varil, �ol�rado 81�57
p. 97�.479.2�39 f. 97�.479.�45� insp�cti�ns 97�.479.Z'�49
ELECTRICAL PERMIT
Job Address: �� VAI L RD VAIL Permit#...: E'I�-�'I 3�
Location.......: UN IT 4�7, VAI L PLAZA H�TEL Proje�t#..: PRJ'I�-��84
Pa r�el No..,..: �1�1�825��41 Issued......: �G1�212�'I�
C]WNER VAIL PLAZA DEVEL�PMENT LL� �61151��1�
15VAILRD
VAI L
CC] 81G57
APPLI�ANT ENC�RE ELE�TRI� 061151�4�� Phone: �97�}949-9�77
PC] B�X 8549
AV�N
C� B�fi�Q
L�cense: 33�-E
C�NTRACT�R EN��RE ELE�TRlC �51151��1� Phone: �97�}949-9277
P� B�X 8849
AVC]N
C� 81���
License: 331�E
Desciption of Work: ADD �IR�UIT F�R CL�-fHES DRYER
Valuat�on: $15�.U0 Square feet: ���
*******************�*******�**********�****************�****************�***********************************************************************
. C�NDI"�I�NS �F APPRC}VAL
Cond: �2
��LD�.}: FIELD �NSPE�TI�NS ARE RE�UIRED T� CHE�K F�R C�DE C�NIPLIAN�E.
C�nd: 42
�BLDG Z��9} CARB�N M�N�XlDE DETECT�F�S RE�UlRED T� BE lNSTALLEa PER ���9 IRC R3'�5
******************************************************��*********************************************�*******************�******.�********�*�****
iNSPECTl�NS
If mor�than two �nspections ar� perfarmed an additional inspectivn fee will be applied for each inspecti�n request�dlneeded.
All elec�rical inspections are perfvrrned on Tuesdays and Thursdays. Requests musf be r�ceived the day before and not later
than 4 p.m.
**********�***********��**************�******��******************************************************************************************�*****�
DE�LARATI�NS
I here�y acknowledg� that I have read this application, fill�d out in full the information requ�red, camp�ete� an a�curate plot
plan, and state that all the informati�n as required is corre�t. I agree ta comply with the information and plot plan, tv comply
with all Town ordinanCes and state laws, and to build th�s sfructure a�cord�ng to the tvwns zvning and subdivision codes,
�esign review ap ro lnternatianal Building and Resident�al �odes and other ordinances af th�T�wn applicable thereto.
,
SIGNATLIRE: Date
�Master 1 homeo r 1 or on-licensed contractor perforrr�ing work}
A
P��NTED NAIVIE: C�
elec_permi 1�0��9
4. � �i�
r�, , ��_ - � , .e;, � _ a s � . �°�
41 T.. y� '�{{�
, T � � �S thb�r�tag�'
�E'�f F �'��t ji��"° � .Y l.�� � � ��r�• � e y� �� •� '�}�2 � �+� Gl
t 5: �'Y'. � �.y� fl` • .;{r�
:"�'..� t k. 's c � .i*91? 'ti-.Ap 1� '' ij..• ,
_ �
�L: ' v A�.. � � ��a�_5� -
�� � � � .._� '� • �
2j� ��L..:e 'Lr �7�� a.��,�i t� � ,,_,e, � . Y� �q '9�
���
�o
yQ:i , "F' y.{e.,hy 1s .F�� .. n,��'7.
B .,�(�"g= J,y,� •: � ��
+ ���} ,�: '�.�i� ' . j�'-.} i e -
_ y�`'' �
ELECTRICAL PERMIT
Electrical Permit Submittal Reauirements Includina Heat Taoe Installation
o Floor plan/Site plan showing proposed work
❑ Building Type
❑ Occupancy Group listed on plans
❑ Load Calculadons and one-line diagram when loads or circuits are being added ��v I O_Q O�S
NOTE: For Multi-Family and Commeraal buildings—plans and calculations must be prepared by a Colorado Licensed Electrical Engineer
Project Street Address: Office Use:
' �ce �'Ad�. Zs„� y2 7 Project#: �1�-�J � G �'"�2��
(Number) (Street) (Suite�
Building Permit#:
BuildinglComplex Name: l��-1L t�?L.�k'Lk- �Tc—` � 2
Electrical Permit#:�l Q�' �( �7�
�Contractor Infortnation:
I Company:
Encore Electric, Inc. Lot#: Block# Subdivision:
�Company Address: PO Box 8849
� Avon CO 81620 Define Scope and Location of Work:
iCity: State: Zip: �..� ��t�'f+CE� �R`CE/Z �
;Contact Name:�nrt�� �s-�-�o�-�.� `
; � C'�eo�cr —r� �at-�r
j Contact Phone: `��G-�-E�l—°��`-{
I ���. c�o„v� ' u
',E-Mail 0.�c�{�qarc�.*^(e, ¢n�w-�e� ;( se additional sheet if necessary)
�
�I Town of Vail C r Registration No.: 331-E `— -
I �Includes Temporary Service: ( )Yes (�lo
/'
on ctor Signature(required) Work Class:
I � New( ) Addition( ) Remodel�') Repair( )
�Property Information 'Other( )
�j Parcei#: 210/U 82854�f� � '�
. i(For parcel#,contact Eagle County Assessors Office at 970-32&8640 or �Type of Building:
�visitwww.eaglecounry.us/patie) �Single-Family( ) Duplex( ) Multi-Family(�j Commercial
�
�Tenant Name: �( ) Restaurant( ) Other( ) _ _
i
�
�Owner Name: ' Date Received:
Provide BOTH square footage of area of work AND Valuation
(Labor�Materials) � � � a �
�Amount of SQ Ft.: /� D �
Electrical$: �.5�� � JUN 11 2010
T��N OF VAIL
oi-r�-io
GENERAL NOTE:
Typical Unit Panel
1. THE SCOPE OF THIS WORK IS
Description Amp Ckt� Ph Ckt# Amp Description TO ADD AN ELECTRICAL
CLOTHES DRYER TO SELECT
KitchenSmallApp#t 20 1 A 2 2o BathroomRecepts/Lights UNITS. THE AFFECTED UNITS
KitchenSrrellApp#2 20 3 B 4 20 BedroomRecepts INCLUDE:
Living Room Recepts 20 5 A 6 20 Kitchen/Liv.Rm Lights
Ftange so � a s zo Fan Coil Units 108 1 14 1 18
2 9 A 10 20 Bathroom Recepts/Lghts 121 2�$ 2 1 4
Dishwasher 20 11 B 12 2o Ba�ony Recept
Refrigerator 20 13 A 14 20 V�Yashing Machine 2�8 222 223
DeckSnowmeft 20 15 B 16 20 Wircowave 224 225 22�
i z �� a, �s so aocnes oryer 308 310 31 1
Snow mett Controls zo �s B 20 2 i 312 313 314
315 316 317
318 321 401
TYPICAL UNIT PANEL SCHEDULE 402 403 404
'� 405 406 407
425 427 501
502 503 504
505 506
TYPICAL UNIT LOAD CALCULATION
SINGLE EXISTING DWELLING UNIT-OPTIONAL METHOD[NEC 220.83(A)]
General Lighting Load[cil 3Va/Sq. Ft(220.12)
1250 Sq. Ft. @ 3Va 3750 VA
(2)Small Appliance Circuits, 1500VA(220.52.A) 3000 VA
(1)Laundry Circuit/Washing Machine, 1500VA(220.52.B) 1500 VA
(1)Dishwasher 1200 VA �l O _. O (Q C/ �..�
(1)Disposal 1176 VA �
(1)Refigerator 1000 VA
(1)Microwa�,e 1100 VA �I d � ����
(2)Bathroom Exhaust Fans 150 VA
150 VA
(1)Range Hood 300 VA � � � � �1/7 f�
(1)Cooktop/Oeen 8000 VA D Li LC'
(1)Clothes Dryer 5000 VA
(1)Deck Snow Melt 3000 VA ' 11 IN 1 1 2��0
(2)Fan Coil Units 324 VA ���
324 VA
Subtotal Non-HVAC Loads 29974 VA
Non-HVAC Loads 100%of 1st 8 kVA plus remainder at 40°/a 16790 VA TO�lVVi� OF VA�L
N/A 0 VA
Subtotal HVAC Equipment 0 VA
Total Demand: 17 KVA
Minimum Feeder Ampacity 81 A �O
Each unit senrice is rated for 125A at 208V/120V Single Phase 3-Wire Q
.
.
.
s •
2 TYPICAL UNIT LOAD CALCULATIONS � �99 =
-� :
.
9°�FS... `�
t�l��c•lric S��NAIENG
nll t ��
��
ENOINEERINQ,LLC 77 Metcalf Road,2nd Floor
4900 West 29th Avenue t1V011�l���1 62�
Denver,CO 80212 (970)949-9277 �+�/�����
(303)955-2084 ICAL CALCULATIONS
www.greenlighteng.com
www.encoreelect.com THES DRYER ADDITION
VAIL PLAZA HOTEL �t CLUB REMODEL JUNE9, zo,o ESK1 . 1