Loading...
HomeMy WebLinkAboutB10-0134NOTE; THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 'MRW0 Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD /ALT MF BUILD PERMIT Permit #: B10 -0134 Project #: PRJ10 -0226 Job Address: 913 LIONS RIDGE LP VAIL Location......: UNIT 315, BREAKAWAY WEST Parcel No....: 210301407015 OWNER WILSON, JOYCE P. & JAMES P. 06/15/2010 18556 E LONG AVE CENTENNIAL CO 80016 APPLICANT BRIGHT DESIGNS BARBIE BRIGHT PO BOX 2133 EDWARDS CO 81632 License: 1009 -B CONTRACTOR BRIGHT DESIGNS BARBIE BRIGHT PO BOX 2133 EDWARDS CO 81632 License: 1009 -B Description: INTERIOR REMODEL Occupancy: R2 Type Construction:VA 06/15/2010 Phone: 970-926-7866 06/15/2010 Phone: 970-926-7866 Status .. : ISSUED Applied..: 06/15/2010 Issued ...: 07/07/2010 Expires ...: 01/03/2011 Valuation: $18,250.00 Total Sq Ft Added: 0 ***«**«******** *rt *rtrtrtrt « + * * * * * * * * * * * * * * * * «rt « « «« rtrt *rt ** «rtrt # #+4 * * * *4 « « « « « « « « « « * * * « * ** FEE SUMMARY « * 4 * * * « « * ** Building Permit Fee ------ > $307.25 Will Cal Fee--------------- - - - - -> $4.00 Total Calculated Fees------ - - - - -> $675.96 Plan Check — ---------- - - - - -> $199.71 Use Tax Fee ------ ------ ------ > $165.00 Additional Fees------------ - - - - -> $0.00 Add'I Plan Check Hours- $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES------ - - - - -> $675.96 Investigation ------- --- ----- > $0.00 Recreation Fee ---------- — ---- > $0.00 Payments - -- - ----------------- - - - - -> $675.96 * * + * « 4 * * *** **rtrt *# rtrt#++*+******************* rtrtrtrt*#**++*+********«*«*«««** Total Calculated Fees--- - - - - -> rtrtrt« rtrtrt* rtrtrtrt44 # # * * «f4 $675.96 « * # * * « «« « * * « « «rt«rtrtrtrt BALANCE DUE ------- — ---- — -------- > ++ rtrt«*++* « * * * * * * * * « * * « « * * * * * * « «f* «rtrtrtrtrt* #rtrt **rt + # $0.00 # # * + + +««4 + * * # * ** *** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FO PECTION SHAL E MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - M. 7 , 7 -la Signature of or tractor , Date Print Name bld_a It_construction_perm it_041908 APPROVALS Permit* B10 -0134 as of 07 -07 -2010 Status: ISSUED Item: 05100 BUILDING DEPARTMENT 07/01/2010 JRM Action: AP Item: 05600 FIRE DEPARTMENT 06/17/2010 drhoades Action: AP See conditions. See the Conditions section of this Document for any that may apply. bld alt_construction_permit_041908 CONDITIONS OF APPROVAL Permit #: B10 -0134 as of 07 -07 -2010 Status: ISSUED Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: CON0011478 Separate permit/shop drawings required for any changes /alterations to the existing fire alarm and fire sprinkler system. A lock -off closet would require sprinkler coverage. bld_a It_construction_pe rm it_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100000812 Amount: $675.96 07/07/201010:31 AM Payment Method: Check Init: LC Notation: 49008 / BRIGHTDESIGNS /LE SOLEIL ----------------------------------------------------------------------------- Permit No: B10 -0134 Type: ADD /ALT MF BUILD PERMIT Parcel No: 2103 - 014 - 0701 -5 Site Address: 913 LIONS RIDGE LP VAIL Location: UNIT 315, BREAKAWAY WEST Total Fees: $675.96 This Payment: $675.96 Total ALL Pmts: $675.96 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ BP 00100003111100 BUILDING PERMIT FEES - - - - -- 307.25 PF 00100003112300 PLAN CHECK FEES 199.71 UT 11000003106000 USE TAX 4% 165.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Project Street Address: JU-_ (Number) (Street) (Suite #) Building /Complex Name: Office Us Project #: Building Permit #: 1 O — t� >4 _ - --- - --- Lot #: Block # Subdivision: Contractor Information Company: 7W.16 Company Address - 6!�!x Z/ a, Detailed Scope and Location of Work: City: �� =`�7 State: � Zip: Contact Name: Contact Phone: �7 e ( e additional sheet if necessary) E -Mail r / 6 d�&_� �O Work Class: Town of Contractor Registration No.: ' / �� New ( )Addition ( )Remodel (v Repair ( ) Other ( ) Signatur & Work Ty e Interior V) Exterior( ) Both( ) Property In formatio U /`f�U �U� ype of Building: Parcel #: Ze / s 6 !� Single Family ( ) Duplex ( ) Multi - Family (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or Commercial( Other visit www.eaglecounty.us /pan ommerca e) ( ) ( ) Tenant Name t<S Does a Fire Alarm Exist? Yes ( No( ) ' 1 / (� ) Owner Name f,��jCS � �c9L1Ge �/ /!S6/(J Monitored Alarm? Yes No ( _ Does a Sprinkler System Exist? Yes ( No ( ) Valuations (Labor & Materials) # & Type of Existing Fireplaces: Gas Appliances Gas Log Wood /Pellet Wood Burning Building: $_ -` �/ _ _ _ - - -� # & Type of P oposed Fireplaces: Gas Appliances Plumbing: $ Gas Log Wood /Pellet Wood Burning Electrical: $ c' % � !o1 1 Mechanical: (including fireplace) $� Date Received: i % i Total: $ /a i i v1 OF 01- Jan -10 BUILDING PERMIT APP Separate permits are required for electrical, plumbin rc hhanical, fireplace, etc. l 1 ZM Final Clearance Air Monitoring Report 936 Lions Ridge Loop, Vail, Colorado 81657 Presented to: Mr. Richard Capra Rocky Mountain Abatement, Inc P.O. Box 621840 Littleton, CO 80162 -1840 Project Details: DSC Project #: 2348 Conducted: June 7, 2010 Performed & Prepared by: Mr. Steve Shurtliff DS Consulting, Inc. P.O. Box 6864 Avon,CO 81620 (303) 378 -1544 I*_- Consulting EXECUTIVE SUMMARY DS Consulting, Inc. (DSC) conducted a final visual inspection, performed aggressive clearance air monitoring, and analyzed clearance air - quality samples via Phase Contrast Microscopy (PCM) for an asbestos abatement project within the residential home located at 936 Lions Ridge Loop, Vail, Colorado on June 7, 2010. Services were provided at the request of Mr. Richard Capra with Rocky Mountain Abatement, Inc. in support of asbestos abatement activities being conducted to remove asbestos - containing drywall and vinyl flooring from a full containment in a portion of the residence. Monitoring locations and frequencies were determined by the DSC- authorized representative Mr. Steve Shurtliff, EPA accreditation No. 15413. PCM analysis was also performed by Mr. Shurtliff (see Appendix B for certification). DSC's scope of work for this project included performing a final visual inspection and collection and analysis of aggressive final air quality samples by NIOSH 582 - trained personnel for determination of airborne asbestos (as total fibers) concentrations in identified areas. DSC is a participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 and has a rating of Proficient. The abatement project passed final visual inspection and the analytical results of all samples collected were below the clearance criteria of 0.01 fibers /cubic centimeter (f /cc) (see Appendix A for Air Sample Analysis). PROJECT INFORMATION CLIENT: Rocky Mountain Abatement, Inc. ON- SITE SUPERVISOR: Mr. Juan Noriega PROJECT LOCATION: 936 Lions Ridge Loop, Vail, Colorado PROJECT CONTACT: Mr. Richard Capra DSC REPRESENTATIVE: Mr. Steve Shurtliff DATE OF SERVICES: June 7, 2010 AIR SAMPLE ANALYSIS: See Appendix A CERTIFICATES: See Appendix B 2 PROJECT INTRODUCTION DS Consulting, Inc. (DSC) conducted a final visual inspection, performed aggressive clearance air monitoring, and analyzed clearance air - quality samples via Phase Contrast Microscopy (PCM) for an asbestos abatement project within the residence located at 936 Lions Ridge Loop, Vail, Colorado on June 7, 2010. The above - referenced services were provided at the request of Mr. Richard Capra with Rocky Mountain Abatement, Inc. in support of asbestos abatement activities being conducted to remove asbestos - containing drywall and vinyl flooring from the residence. Sample locations were determined by the authorized representative, Mr. Steve Shurtliff of DSC. Mr. Shurtliff is a State of Colorado certified Air Monitoring Specialist, EPA certificate No. 15413. PCM analysis was performed by Mr. Shurtliff. SCOPE OF WORK DSC's scope of work for this project included conducting a final visual inspection, performing aggressive clearance air monitoring and analyzing clearance air - quality samples via Phase Contrast Microscopy (PCM) using NIOSH 582 - trained personnel for the determination of airborne asbestos concentrations (as total fibers) in the containment area(s). DSC is a participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 and has a rating of Proficient. The analytical results of all air clearance samples collected were below the PCM clearance criteria of 0.01 fibers /cubic centimeter (f /cc). AIR MONITORING Air - quality samples were collected utilizing a modified NIOSH 7400 Method, whereby samples were collected on 25- millimeter (mm) mixed - cellulose, ester- membrane filters with 0.45- micron pore size and analyzed via Phase Contrast Microscopy (PCM) as per the customer's requirements. Sample Collection - PCM samples, when applicable, were collected on 25- millimeter (mm) mixed - cellulose, ester- membrane filters with 0.45- micron pore size with an effective collection area of 385 mm. All filters were pre - assembled by the manufacturer in three stages, conductive sampling cassettes with extension cowls. Air samples were collected at flow rates of approximately 12.5 liters per minute (L /m) using Thomas high - volume pumps with a minimum of 1,200 liters being collected. Flow rates were collected at the beginning and at the end of the sampling period utilizing an airflow rotameter calibrated against a primary -flow calibration instrument. Start times and stop times were recorded for all sampling periods. A field blank and lab blank were also collected and analyzed along with the five (5) clearance samples. PCM Sample Analysis Method - PCM samples were analyzed according to a modified NIOSH 7400 Method —A Counting Rules— although samples were collected on 25 -mm mixed - cellulose, ester - membrane filters with 0.45- micron pore size and analyzed via PCM. Air sample results contained in this report have been calculated with blank sample corrections. APPENDIX A - AIR SAMPLE ANALYSIS Sample Date: June 7, 2010 AMS /Analyst: Mr. Steve Shurtliff Client: Rocky Mountain Abatement, Inc. DSC Project #: 2348 Project Location: 936 Lions Ridge Loop, Vail, Colorado On -site supervisor. Mr. Juan Noriega Saniple NUmber CL -1 PUMP Sainple .• Locatioii Hi vol. Kitchen Avg. 12.5 Start 2:35 Stop 4:25p Thne 110 Vol. 1364 Fibers/ 3.0/100 0.001 CL -2 Hi vol. Kitchen 12.5 2:35 4:25p 110 1364 3.0/100 0.001 CL -3 Hi vol. Hallway 12.5 2:35 4:25p 110 1364 2.5/100 0.001 CL -4 Hi vol. Bathroom 12.5 2:35 4:25p 110 1364 2.5/100 0.001 CL -5 Hi vol. Bathroom 12.5 2:35 4:25p 110 1364 3.0/100 0.001 CL -lb n a Lab Blank n a n a n a n a n a 0/100 0.000 CL- tb n a Field Blank n a n a n a n a n a 0/100 0.000 4 APPENDIX A - AIR SAMPLE ANALYSIS Sample Date: June 7, 2010 AMS /Analyst: Mr. Steve Shurdiff Client: Rocky Mountain Abatement, Inc. DSC Project #: 2348 Project Location: 936 Lions Ridge Loop, Vail, Colorado On -site supervisor. Mr. Juan Noriega Sample NUmber CL -1 Type Location Hi vol. Kitchen 12.5 2:35 • 4:25p 110 1364 Results 3.0/100 0.001 CL -2 Hi vol. Kitchen 12.5 2:35 4:25p 110 1364 3.0/100 0.001 CL -3 Hi vol. Hallway 12.5 2:35 4:25p 110 1364 2.5/100 0.001 CL -4 Hi vol. Bathroom 12.5 2:35 4:25p 110 1364 2.51100 0.001 CL -5 Hi vol. Bathroom 12.5 2:35 4:25p 110 1364 3.0/100 0.001 CL -lb n a Lab Blank n a L n a n a n a n a 0/100 0.000 CL -fb n a Field Blank n a I n a n a n a n a 0/100 0.000 4 APPENDIX B - CERTIFICATIONS o it d►f {Wt >� 6 a '4 a s ° 'R B STATE OF COLORADO ASBESTOS CERTIFICATION* xj t'ulorado Department of Public Health and [mvonnu:nt Air Pollution Control Division This CCftIfnCS that Steve Shurtliff C NO: 1 '4 13 has net the requirements of 25- 7.507, C.R.S. and .Air Quality ClmWl Commission Regulation No. 8, Part B. and is hereby certified by the state of Colorado in the following discipline: Air Monitoring Specialist* Imued: 9111/2909 E7piro nn: 9/1112919 .t.� 3,_ •Ila �b N/W/^+nv al�tipMJ�.prlM w.,.l�w _ ik anakr...rrbryr..lKyrrd.,. E nvironmenral T raining & C nsulring 2761 WeftWaJ A,awe •7 Fii k-Ood. Coliandnn 8011 i 303 7814421 CERTIFIES MA "f STEVE SHURTLIF has successfully completed THE NIOSH 582 EQUIVALENT COURSE SAMPLING & EVALUATING AIRBORNE ASBESTOS DUST Corse Date: _- I - & )8 Nw of hoes: 94 ExnaDow W Certificate No,: 1>Mq" -L VVV ��` Awrxuixd tiigrwure It Asbestos Inspection and Sampling Report 963 Lion's Ridge Loop, Unit 315 in Vail, Colorado 81657 Presented to; Ms. Barbie Bright Bright Designs PO Box 2133 Edwards, CO 81632 Performed by Mr. Brandon Sinkbeil DS Consulting, Inc. PO Box 6864 Avon,CO 81620 (970) 476 -4182 Project Details. DSC Project #: 2238 Conducted: May 7, 2010 I* Consulting EXECUTIVE SUMMARY On May 7, 2010, Mr. Brandon Sinkbeil of DS Consulting, Inc. (DSC) performed a limited inspection and asbestos sampling at 963 Lion's Ridge Loop, Unit 315 in Vail, Colorado, in order to identify potentially hazardous friable and non- friable asbestos containing materials (ACM) within a portion of the above - referenced residence scheduled for a remodel. Mr. Sinkbeil performed asbestos bulk - sampling of drywall (surfacing material) and vinyl flooring (miscellaneous material) in a total of six (6) locations within the kitchen of the residence. All six (6) bulk - samples were analyzed by Aerobiology and Associates Laboratory, Inc. (NVLAP # 200860 -0) with five (5) laboratory results being positive for ACM between 2% and 60% Chrysotile (see Appendix B for laboratory results). The followingsaninled materials were found to contain asbestos greater than 1% (ACM): Sample Sample Material Friable or Estimated Material Asbestos Location Number Classification Non - Friable Quantities* Condition Content Kitchen Wall DW -01 Surfacing Material Friable +/ -140 ftz Good 3% Drywall Chrysotile Kitchen Wall DW -02 Surfacing Material Friable +J -140 ftz Good 2% Drywall Chrysotile Kitchen Wall DW -03 Surfacing Material Friable +/ -140 ftz Good 2% Drywall Chrysotile Kitchen Vinyl VF -01 Miscellaneous Material Non - Friable +/- 78 ftz Good 60% Flooring Chrysotile Kitchen Vinyl VF -02 Miscellaneous Material Non - Friable + j- 78 ftz Good 60% Flooring Chrysotfle "Quantities are approximations and subject to field verification. 2 PROJECT OVERVIEW 1. Introduction A limited inspection and bulk- sampling for ACM was conducted at 963 Lion's Ridge Loop, Unit 315 in Vail, Colorado, by Mr. Sinkbeil on May 7, 2010, at the request of Ms. Barbie Bright with Bright Designs. Mr. Sinkbeil is a Colorado State Certified inspector, and has EPA Accreditation #13442 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non - friable ACM from within the kitchen areas of the residence scheduled for a remodel. II. Structural Design The structure is a wood - framed, single family condominium within a larger, multi-unit building. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA- accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk- sampling techniques. The asbestos bulk- sampling was conducted on suspect ACM with a limited number of bulk - samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency /AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk - samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if. 1. They exhibit similar physical characteristics; and 2. The application of the sampled material can be correlated to the application of un- sampled material. 3 Bulk - samples collected were analyzed utilizing the EPA's Method -f or the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk - samples was performed on the "date reported," as listed in the bulk - sample analysis report. IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous: other suspect materials, floor tile, sheet vinyl /linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: ■ The surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: ■ The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). ■ One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. ■ Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. 11 Response - action recommendations for asbestos containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates an imminent hazard exists and should be addressed as soon as possible. A general recommendation indicates no imminent hazard exists and no further abatement activities are required for removal of the material. V. Inspector Comments ACM was identified during the bulk - sampling conducted at 963 Lion's Ridge Loop, Unit 315 in Vail, Colorado. A total of six (6) bulk - samples were collected from the above - referenced address. Five (5) bulk - samples tested positive (greater than 1 %) for asbestos. Asbestos was identified in the kitchen drywall (surfacing material) sample Nos. DW -01, DW -02, and DW -03 at 2 -3% Chrysotile. Asbestos was identified in the kitchen vinyl flooring (miscellaneous material) sample Nos. VF -01 and VF -02 at 60% Chrysotile VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent - asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the kitchen area of the residence at 963 Lion's Ridge Loop, Unit 315 in Vail, Colorado, on May 7, 2010. The quantities are approximations and are. subject to field verification: Homogeneous Area #01 Homogeneous Area #01 - Physical Description (layers): White Tape; Pink brown drywall; White compound Physical Description (layers): White Tape; White compound; Pink brown drywall Material Classification: Surfacing Material Material Classification: Surfacing Material Sample Location: Kitchen Wall Drywall at Closet Sample Location: Kitchen Wall Drywall behind Refrigerator Material Condition: Good Material Condition: Good Material Quantity: +/- 140 ft Material Quantity: +/- 140 ft Sample #: DW -01 Sample #: DW -02 Asbestos Content (layers): None - detected; None- detected; None - detected Asbestos Content (layers): None - detected; None - detected; None - detected Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII 5 Homogeneous Area #01 Homogeneous Area #02 Physical Description (layers): White mastic; Tan /gray sheet vinyl w gray fibrous backing Physical Description (layers): White mastic; Tan /gray sheet vinyl w ay fibrous backin Material Classification: Surfacing Material Material Classification: Miscellaneous Material Sample Location: Kitchen Wall Drywall behind Refrigerator Sample Location: Kitchen Vinyl Flooring Material Condition: Good Material Condition: Good Material Quantity. +/ -140 ft Material Quantity. +/- 78 ft Sample #. DW -03 Sample #: VF -01 Asbestos Content (layers): None - detected; None- detected Asbestos Content (layers): None - detected; None - detected Recommendations IMMEDIATE - See Section VII Recommendations. IMMEDIATE - See Section VII Homogeneous Area #02 Homogeneous Area #02 Physical Description (layers): White mastic; Tan /gray sheet vinyl w / gray fibrous backing Physical Description (layers): White mastic; Tan /gray sheet vinyl w / gray fibrous backin Material Classification: Miscellaneous Material Material Classification: Miscellaneous Material Sample Location: Kitchen Vinyl Flooring Sample Location: Kitchen Vinyl Flooring Material Condition: Good Material Condition: Good Material Quantity. +/- 78 ft Material Quantity: +/- 78 ft Sample #: VF -02 Sample #: VF -03 Asbestos Content (layers): None - detected; None- detected Asbestos Content (layers): None - detected; None - detected Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII VII. Recommendations IMMEDIATE The laboratory results of the potential ACM sampled at 963 Lion's Ridge Loop, Unit 315 in Vail, Colorado, Colorado, on May 7, 2010, indicate that five (5) bulk- samples were reported as positive for asbestos between 2% and 60% Chrysotile. Asbestos was identified in the kitchen drywall and vinyl flooring. Since the above - referenced material is to be removed from the residence and the total quantity exceeds any of the regulatory trigger levels of 50 linear feet on pipes, 32 square feet on other surfaces, or the volume equivalent of a 55- gallon drum, a Colorado - licensed asbestos abatement contractor is required to perform the removal, including formal notification to the Colorado Department of Public Health and Environment prior to the abatement of the ACM. APPENDIX A CERTIFICATION Colorado Department of Public Healthy and Environment Air Pollution Control Division This terrifies that 1 Brandon Sinkbeil Certification No: 13442 has met the requirements of 25 -7 -507, C.R.S. and Air Quality Control C Commission Regulation No. 8, Part B, and is hereby certified by the state of Colorado in the following discipline: , Building Inspector* Issued: 5/16/2010 Expires on: 5/16/2011 Au APMRepreseMalm • Tk" cari /kaor is w!i/ only wits Me prrvessiew Oje crrrewt Dirisiow- rpprnrd tniriwR caarrfe cesslficrrfiwe is Ike disco/iwe speufted a"m 7 APPENDIX B LABORATORY ANALYSIS Q cc%Q,� N+S N a� 33 .n u a v e a 7 9 S a ° o 0 N 04 N N . c � L O N ° Y ;d 'b G 7 I 4 Z xLi: = Q 4 � a G O i✓ x W °1 U z v 4: c 67 X 'L r 3 > >a > >a > > z Q U u C U on J y • to z Q � z 4 z oe z z z z C N ° � Q �-X OY� w Z U.E C4 O W O n p M Cl • s t� � � Lb � e G. � C Y/ �J O L O e ' N g a 49 O^ T H v � 3 Z z S u -b Vi vi yj in U U Q ri M ro F- Y.. .+ U a ° o 0 N 04 N O N ° xLi: o Lti O i✓ x W °1 U z > >a > >a > > > U u m U on J y • to z r/I 0 �1 z VJ oe z oe z z z z N Q O e ' N O 49 O^ r- 7- a �� Vi vi yj in M ri M �n vi � O z z z z z z z z z z v n � ^7 C G E e 7 a � >~ = o Is = a m .� a v e U � r 3 v al 3 _ .°' � ¢ � I .� 3 a L E e LL' CJ Q N N M en M v a a a a a a E c a 01 C11 V4 a C11 a C11 a C4 0, C4 °C C V7 O O O O C O O O O O e 3 d 0 0 n �•� H Jill H II H H H 11 r, ti GU >O� - -aomoc F � ,C V- za= �; uuuHn us - u •3c�z,.�U u e U u Ft V QII II� 11 B H uzz�a QQQCrC;FF- n L T � O .T o � a Q o C ^ o --, "�k pf v O OD a d •-cam a veQ r S�i AC1AA � a a LTr ru a :i a °moo z a C a 44 M ` a :n N V ¢ 6 i U •� a U 3 . F u U =a a[; F 0 M E. m a w f N 0. z O U D z 0 z Tz . C3 o = t F— r iJ1 o ri v, o �p O M sv O Q O uj V o Udt> c U*% F g . a LTr v a ° °moo z '3 :n i-•• E U F u U qp a[; F 7 E V bL cD N 0. z z z z 0 z z . C3 a, Q z ,n vi v1 ri M ,., N N M M A C z z z z z z z z z z G Z J •c o � c � � c ,o c � 3 c Z 5 F o i s is I T = a a C ". C a�i o� a o` a N N N N N N N N N C+i C O O ^ O O O q R y y JOB C p N fir; m� "3�� N !I II N ft N !I ft N� N GU >C7�FaGC¢GC] `c , !I N ft ft ft l! �.• d Csz xU a �' U:gu.v:3zzwQ d N u ;.cc QQQUUFF n v �o a v d `o v� a 721 2 7a Cfl tx 0.� 72 -X all rL 8 2 .6 0 -,4 -2 -C 2 U 'LI LLJ 721 0.� O v� r ;-_� = cru>u pox m > <C o < < < < E 2 71 E< • i a V L Y � r O O a O C d. 5 y O n - g 7 B G •'�' `s O 6Y C 1l uaaa 222Y �AqG m g V Y s Q d O O V n � a C y V 1 C bu u E o ° 9 4 O L L a ~ o Q n O T = O ra a �D O � r u w Z u O c ? a bat '52 9! H L u �) Qv'' • i a V L ti .O K m 79 N J T c 77 r U F' r N r� O R 0 G li O 3 O N . ^J Y 3 v y O y n � a C y 1 bu u E o ° 9 L a ~ o ° ; 5 = ra a $ u ? '52 9! H 75 O C C v a '•c ir. J C Q 1 5 E Q p a y '� u ♦ 3 W � 'g a o a L qj on C 0 U 3 on .9 G U C G ow a A2 r v E Gaaj o 9 o co O R ^ " O 7 G C r n `G 5- 9 bo 6 rL w C y y H y C ti .O K m 79 N J T c 77 r U F' r N r� O R 0 G li O 3 O N . ^J Y 3 v A 08 -30 -2010 Inspection Request Reorting Page 1 4'34 pm Vail, GO - City Of Requested Inspect Date: Tuesdayy August 31, 2010 Assigned To: CGUNIO�V Inspection Type: BLDG Inspection Area: CG Site Address: 913 LIONS RIDGE LP VAIL UNIT 315, BREAKAWAY WEST A /P /D Information Activity: B10 -0134 Type: A -MF Sub Type: AMF Status: ISSUED Const Type: Occupancyy: Use: VA Insp Area: CG Owner: WILSON, JOYCE P. & JAMES . Contractor: BRIGHT DESIGNS Phone: 970 - 926 -7866 Description: INTERIOR REMODEL Requested Inspection(s) Item: 90 BLDG -Final Requested Time: 08:00 AM Requestor: BRIGHT DESIGNS Phone: 970 - 926 -7866 Comments: 331 -9656 Assigned To: I Entered By: JMONDRAGON K Action: Time Exp: Thll s Inspection Histo Item: 30 BLDG - Framing ** Approved ** 07/23/10 Inspector: mdenney Action: APCR APPROVED /CORRECTION REQD Comment: Fireplace vent has been pulled loose, re- attach. Maintain fire ceiling assembly. Item: 50 BLDG - Insulation Item: 60 BLDG - Sheetrock Nail **A roved ** 07/28/10 Inspector: MDEN Y Action: AP APPROVED Comment: connection of fireplace vent has been re- established. Item: 70 BLDG -Misc. Item: 90 BLDG -Final REPT131 Run Id: 11853