HomeMy WebLinkAboutB06-0280 Rev. # 7TOWN OF VAIL DE1-. - ATMENT OF COMMUNITY DEVELOPI „..sNT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW MULTI -FAM BUILD PERM
Job Address: 442 S FRONTAGE RD WEST VAIL
Location.....: APOLLO PARK
Parcel No...: 210108246023
Legal Description: I I ` S 6� _ (j 6 c( 'i
Project No.:
Permit # B06 -0280
Status ... .
Applied ..
Issued . . .
Expires. .:
�” 1�
ISSUED
09/14/2006
09/21/2007
07/25/2007
OWNER BYRNE, RON 09/14/2006
285 BRIDGE ST
VAIL
CO 81657
APPLICANT BYRNE, RON 09/14/2006
285 BRIDGE ST
VAIL
CO 81657
ENGINEER MONROE- NEWELL ENGINEERS INC.09 /14/2006 Phone: 970 - 949 -7768
PO BOX 1597
AVON
CO 81620
License: C000002150
CONTRACTOR R.A. NELSON 02/14/2007
ARCHITECT RESORT DESIGN ASSOCIATION 09/14/2006 Phone: 970 - 949 -0899
PO BOX 6836
AVON
CO 81620
License: C000002149
Desciption: Town of Vail Adjusted Valuation:
MOUNTAIN VIEW RESIDENCES -NEW CONSTRUCTION OF A MULTILEVEL
CONDO/ GARAGE. Revision Valuation:
Occupancy Type Factor Sq Feet Valuation
RESIDENTIAL/MULTFAM( ZONE 3 IIB 150.64 63,082 $9,502,672.48
STORAGE/LOW HAZ(S2) ZONE 3 IIB 98.55 48,037 $4,734,046.35
Totals... 63,082$34,800,000.00*
4,800,000.00
Fireplace Information: Restricted: Y # of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0
e***+►*** t* r***+*+***►* tst+***+** * * *� *► *x * +t * * * * * * *•x *r► * * * * * * +* FEE SUMMARY t******++*+*********•* s*+* * *s *r * *r * *s * * * + * * * * * *rr *t * * * * *+
Building ------ >
128, 978.75 Restuarant Plan Review - ->
$0.00 Total Calculated Fees --- >
275, 899.94
Plan Check --- >
$83,836.19 Recreation Fee--------- - - - - ->
$63,082.00 Additional Fees------ - - - - ->
$300. 0 0
Investigation ->
$0.00 TOTAL FEES ------------- >
275,899.94 Total Permit Fee — -------- >
276,199.94
Will Call - - - - ->
$3 . 00
Payments ------------------- >
276, 199.94
BALANCE DUE --------- >
$0.00
■**** �►* �* x*** �+ �* r* t* �** v* �* +:s *� * * *► * * * ++ + * *� * * *� *� * + * * * ** apt*►******
�* r* �**** �* �x«**+********** �* a�* �+* av* trvt* *. * * *■�+r♦ *t *trr� *rs■ * * *r�� *��*
Approvals:
Item: 05100 BUILDING DEPARTMENT
12/05/2006 jplano Action: DN COMMENT LETTElu aENT 10/16/06
01/15/2007 jplano Action: AP Full Building Permit
03/29/2007 jplano Action: AP IR:3411; Staging plan stamped by TOV dated
03/14/2007.
Additional $120 due for 2 hours plan review.
04/09/2007 JPLANO Action: PA Rev.4- IR #3621- Shop drawings submittal 1
Additional $0
04/30/2007 jplano Action: AP Approved Rev 3 and Rev 5, eliminated firep.
new
entry details, revise flat roof detail, supplied boulder wall details, 2 hours of
review
due $120.00
09/17/2007 ependley Action: AP Rev7 /IR5466. Change in shoring approved. N(
valuation. Added plan review fee of $60.00 due
Obtained Verbal Approval From Public Works to release the shoring changes
Item: 05400 PLANNING DEPARTMENT
01/05/2007 George Action: AP
03/21/2007 George Action: PA This is a partial approval for a Construct:
Staging
Plan and Trafic Control Plan, dated March 14, 2007
Item: 05600 FIRE DEPARTMENT
10/03/2006 mvaughan Action: DN Plans need to reflect the following:
1. Show ownership of fire staging
2. Record staging plat with county
3. Show signage plan
4. Show access to 2 fire hydrants /confirm adequate flow.
5.FDC at garage not shown.
6. FACP location not indicated.
7. FD access to top deck of parking deck not clear.
8. Pedestrian egress from parking garage to public way not clear.
9. show parking plan
FA l.la illegible, not approved.
FA l.lb standpipe to be located inside stairway.
fp1.2b show firefighter access to facp.
12/27/2006 McGee Action: PA I have completed the review of the resubmit
fire department issues. The results are as follows:
1. C 3.1 The 4o cross slope at the fire dept staging area is a concern. Fireflow
requirements
for the project requires two pumpers. Access to a second hydrant and staging are i
clear.
2. A 0.1 The trash room is not readily accessible nor is there a fire hose valve
reasonable proximity.
3. L 1 & L 2 The fire department connections and fire hydrants are not shown. The
landscape
plan indicates the fire department connections and hire hydrants will be obstruct(
4. FP 1.2B & A 3.2 B need to be coordinated. Fire hose valves are to be sixty incJ
finished floor, not six feet.
5. A 2.1B does not ind_ Ate the exit door trom the ga .Age. The concern is clearen(
garage exhaust tan is shown over the top of the fire command room. Adequate tire :
hour) is required if this configuration exists or remains.
6. A 3.3B Gas meters are shown on the south side of the garage on this sheet only
NOTE: The gas meter locations are not consistent. Gas and electrical meters must 1
protected
trom snow and ice accumulation. Resubmit gas meter locations on a plan approved b,
Energy. Provide elevations and site plan.
7. A 4.2 b Show roof access.
8. A 7.2 Provide tire rating on ployisocynatic insulation and method of attachment
Provide
flame spread and flash point data if using mastic.
9. M 2.6 Show access past fans on roof.
Refer
10. E Series The tire alarm devices and locations on the electrical plans are rejf
to FA series plans.
11. Provide stamped fire protection and fire alarm plans.
12. Provide specifications on gas log sets with make and model number to prove cot
with firebox manufacturers specifications and UL listings.
13.. FDC's in planter to not conform with FP plans or specifications.
End 12/26/06
Item: 05500 PUBLIC WORKS
01/05/2007 CSalli Action: AP Sheet M -1: separate heat zones for heated i
ROW
Sheet L -1: Relocate proposed trees out of ROW and onto private property
Sheet L -2: Remove note calling out proposed stone veneer retaining wall just west
proposed
driveway
Item: 05550 ENGINEERING CIVILS
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 479 -2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.
TURE OF OWNER OR
OWNER
PAGE 2
************************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
CONDITIONS
Permit # B06 -0280 as of 09 -21 -2007 Status: ISSUED
************************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Type: NEW MULTI -FAM BUILD PERM Applied: 09/14/2006
Applicant: BYRNE, RON Issued: 09/21/2007
To Expire: 07/25/2007
Job Address: 442 S FRONTAGE RD WEST VAIL
Location: APOLLO PARK
Parcel No: 210108246023
Description:
MOUNTAIN VIEW RESIDENCES -NEW CONSTRUCTION OF A MULTILEVEL
CONDO/ GARAGE.
****************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Conditions:*************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
Statement Number: R070001946 Amount: $4,878.00 09/21/200704:44 PM
Payment Method: Check Init: LT
Notation: Lunar Vail / ck
#3128
----------------------------------------------------------------------- - - - - --
Permit No: B06 -0280 Type: NEW MULTI -FAM BUILD PERM
Parcel No: 2101 - 082 - 4602 -3
Site Address: 442 S FRONTAGE RD WEST VAIL
Location: APOLLO PARK
Total Fees: 276,199.94
This Payment: $4,878.00 Total ALL Pmts: 276,199.94
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 BUILDING PERMIT FEES 2,920.00
PF 0010000311_310 PLAN CHECK FEES 1,898.00
PF 00100003112300, PLAN CK - project GFP012 60.00
LICATION WILL NOT BE ACCERZED IF INCOMPLETE OR UNSIGNED
Building Permit # 06
TO O REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
** *All Revision submittals must include the Field Set of approved plans. 6tcr�s ev;ti
will be preformed until the revisions are approved.
CEP 1..1 2001
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: I Contact and Phon AIL
ATTENTION: JOE, JR, C IE, GREG, CHRIS
Contractor Signature:
... . I wT10%un r'r%n M1111 r\IK[fl- DCDMIT 11 nhnr R Materials)
%ovivlr•LCIG r%L;Vi w�r�7
REVIS AMOUNT: $ �, C
`C ,Ctic,
�v�+wr�wow v.. vv.�.�•• --- -
ELECTRI $ — 1
- - - -•- --
OTHER: $
PLUMBING: $
MECHANICAL: $
REVISED TOTAL: $
w ______ -- ^sr_ s n17n 1 100 - IZA/I nr vicif unnnw/ P.A(7/P.- countv.com
rorrdreeI it c.vnulEi c ^ a ►c vvu„a r.��`��... -• •- -- -- - -
DO 61
Job Name: dv V V�.�..
VA.�L �
Job Address: AD
A (_ 4> S6 t hS
Legal Description Lot: [ Block: Filing: Subdivision: -Tz, wok VAz1_
Owners Name:L aQ �/� Address: CBS (S�b c t_ 5T t/4a—L,ro Phone: 4�-
Architect/Designer:
Rtsd fl
Engineer:
/�I,,P, L4X. Cc.[.
Address: 30 w. -jc'w- �„a+ca�c STS �10
A�A--, z
Address: 6�.�c� 8 R• S'1 G.t�Y
c o
Phone:
Phone: �.b
REASON FOR REVISIONS: C t� ; ,✓ -� p�2 �42� S lf�z�'v4 1�5�4
Work Class: New k� Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( )
Work Type: Interior ( ) Exterior ( ) Both}
Does an EHU exist at this location: Yes( ) No
Type of Bldg.: Single- family ( ) Two - family ( ) Multi- family X) Commercial (te Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building:
No. of Accommodation Units in this building:
No/Type of Fireplaces Existing: Gas Appliances Gas Los Wood /Pellet Wood Burnin
No/T e of Fire laces Proposed: Gas Appliances Gas Los Wood /Pellet Wood Burning NOT ALLOWED
Does a Fire Alarm Exist: Yes( ) No( )
Does a Fire Sprin kler System Exist: Yes( } No ( )
*****FOR OFFICE US ONLY*****
F: \cdev\ FORMS\ Permits\ Building\ building_revision_4- 18- 2007.doc Page 1 of 1 4/18/2007
d
builtinc.
Building Department Services
September 17, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT:
PERMIT NUMBER:
REVISION NUMBER:
INTERNAL REF #:
ADDRESS:
Dear Mr. Davis:
Change in Shoring
B06 -0280
7
5466
442 S. Frontage Rd
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Structural Design Calcs, 4 pages of plans on shoring design
Plan review fee: $60.00
No additional square footage- No added valuation
Sincerely,
Matthew Royer
Building Official
SAFEbuilt Colorado
P.O. Box 1618
Eagle, CO 81631 -1618
(970)328 -1790
(877)428 -6412
matt.royerkSAFEbuilt. com
Page 1 of I
SAFEbuilt Colorado Eagle Office ✓ P.O. Box 1618 ✓ 1286 Chambers Avenue, Unit 101 ✓ Eagle, Colorado 81631
Phone: (970)328 -1790 ✓ Toll Free: (877) 428 -6412 ✓ Fax: (970) 328 -1791 ✓
C:\ Users\ ependley .CIA3 \AppData \Local\Microsoft \Windows \Temporary Internet Files\ Content. IE5\ 99T3228T \tov- b06- 0280.rev7_FAL[ 1 ].doc
COGGI NS & SO
►;
TO
T'ri - fm rrf Van
OE &:4i6 Vwx a
Caisson Drilling, Excavation Shoring, Tieback Anchors
STRUCTURAL DESIGN CALCULATIONS
EARTH RETENTION
for
PROJECT NO. -
MOUNTAIN VIEW RESIDENCES ON GORE CREEK
Prepared for
CLIENT: R. A. NELSON
ADDRESS: 51 EAGLE ROAD #2
CITY: AVON STATE: CO 81620
TEL: 970-949-5152 FAX: 970-949-4379
p RE
AY De
Prepared By:
JOHN H. HART, P.E.
COGGINS & SONS, INC.
DATE: SEPTEMBER 5, 2007
9512 Titan Park Circle • Littleton, Colorado 80125 • (303) 791 -9911 • FAX (303) 791 -0967
COGGI NS & SO
E-
Caisson Drilling, Excavation Shoring, Tieback Anchors
STRUCTURAL DESIGN CALCULATIONS
SUBMITTAL INDEX
for
PROJECT NO. -
PROJECT: MOUNTAIN VIEW RESIDENCES ON GORE CREEK
ITEM NO. I DESCRIPTION I PAGES
1
SUMMARY OF SOIL DESIGN DATA AND EARTH PRESSURE 30 FT HEIGHT
S1.0-S1.1
2
EXISTING SUGAR BUILDING SURCHARGE
S1.1
3
"LPILE 5.0" ANALYSIS OF CANTILEVER DRILLED SHAFT 30' -0" HEIGHT EXPOSED - 25' -0" EMBEDMENT
S2.0-S2.12
4
STRUCTUAL CALCULATIONS OF REINFORCMENT STEEL 30' -0" HEIGHT EXPOSED - 25' -0" EMBEDMENT
S3.0-S3.1
5
"LPILE 5.0" ANALYSIS OF CANTILEVER DRILLED SHAFT 34' -0" HEIGHT EXPOSED - 26' -0" EMBEDMENT
S4.0-S4.12
6
STRUCTUAL CALCULATIONS OF REINFORCMENT STEEL 34' -0" HEIGHT EXPOSED - 26' -0" EMBEDMENT
S5.0-S5.2
7
SHOTCRETE FACING
S6.0
APPENDIX "A ", REFERENCE MATERIAL AND CODES
9512 Titan Park Circle • Littleton, Colorado 80125 • (303) 791 -9911 • FAX (303) 791 -0967
COGGINS & SON Name T, 14-
PH. (3031791 -9911 FAX(303)797-0967 PROJECT:
CAISSON DRILLING
EARTH RETENTION
TIE BACK ANCHORS SUBJECT:
u C;l e <> 4 �
HP It t 0 f o;z" - 7 D ATt4
, 9'� 14-
Git 0
WM
1 3 [-10 �
5 4 600
8 1 S ° t
,5 6. " 1 C.,
51.0
PROJECT NO.:
DATE: '15 1 - a- -- I I .
x A
(? e-r G S JAY
L5
V ;4
H
ko-
el
0
f .
I V/
Irstn TC?
(OGGINS & SONS, /� Name J H A —
PH. (303)791 -9911 FAX(303)791 -0967 vLt LL ,.
CAISSON DRILLING PROJECT:
EARTH RETENTION z �� r �
TIE RACKANCHORS SUBJECT:
- 1
c- ' _ -, o tA
PROJECT NO.: `
DATE: f f
-1 °�
2 Jo F
51 �
to V-- F
Computed by LPILE Plus for Windows, Ver. 5.0, (c) 2002 byENSOFT, Inc.
-0.1
O
NEW
v
nor.-O
O
4
s
CL }' N
d �
It
r
CO
r
O
r
O
N
N
N
N
Lateral Deflection (in)
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
r I I I I I I I I I lv 30 H - 6 FT S PA C IN G
v 30 H - 6 FT SPACING
�r
M
r
N
r
r
r
i-.
O
� O
v
C
O
V O
� O
d
O
d
K
0
0
v
0
M
O
N
O
1 7
O
O L
0
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300
Pile Length (in)
rte.
N
It
J
E]
O
E
s
CL
4)
0
00
N
N
N
ICT
N
Unfactored Bending Moment (in -kips)
0 2000 4000 6000 8000 1E4 1.2E4 1.4E4
I I I I I 1 Iv 30H - 6 FT SPACING
A
Mmirl-
N
<r7
00
O
r
E
L
d �
It
r
r
r
O
N
N
N
It
N
Shear Force (kips)
-120 -100 -80 -60 -40 -20 0
20 40 60 80
v 30 H - 6 FT SPACING
N
C
y
Y
W
N
N
d
C
CO)
C
d
IM
w
00
w
CR
ri
00
W
Cl)
00
W
v
V)
00
W
N
Cl)
00
W
M
00
.1J
N
00
L
N
00
L
:V
00
L
N
:V
00
L
N
p
L
b
r
L
D
r
b
L
7
r
b
L
V
r
b
L
L
U
0
U
u
V
v Thrust = 30 kips
2000 4000 6000 8000 1E4 1.2E4 1.4E4 1.6E4
Bending Moment (in -kips)
30HEIGHTSCI3- #11.lpo
LPILE Plus for Windows, version 5.0 (5.0.1)
Analysis of Individual Piles and Drilled Shafts
Subjected to Lateral Loading using the p -y Method
(c) Copyright ENSOFT, Inc., 1985 -2004
All Rights Reserved
This program is licensed to:
JOHN H. HART
COGGINS
Path
to
file locations:
C: \Documents and Settings \COGGINS AND SONS \My
Documents \2007JOBS \MOUNTAINVIEW\
Name
of
input data file:
30HEIGHTSCI3- #11.lpd
Name
of
output file:
30HEIGHTSCI3- #11.lpo
Name
of
plot output file:
30HEIGHTSCI3- #11.lpp
Name
of
runtime file:
30HEIGHTSCI3- #11.lpr
------------------------------------------------------------------------------
Time and Date of Analysis
------------------------------------------------------------------------ - - - - --
Date: September 5, 2007 Time: 13:50:56
------------------------------------------------------------------------------
Problem Title
------------------------------------------------------------------------ - - - - --
MOUNTAIN VIEW - 30 HT
------------------------------------------------------------------------------
Program Options
------------------------------------------------------------------------------
Units used in Computations - US Customary Units, inches, pounds
Basic Program Options:
Analysis Type 3:
- Computation of Nonlinear Bending stiffness and ultimate Bending Moment
Capacity with Pile Response Computed Using Nonlinear EI
Computation Options:
- only internally - generated p -y curves used in analysis
- Analysis does not use p -y multipliers (individual pile or shaft action only)
- Analysis assumes no shear resistance at pile tip
- Analysis includes automatic computation of pile -top deflection vs.
pile embedment length
- No computation of foundation stiffness matrix elements
- output pile response for full length of pile
- Analysis assumes no soil movements acting on pile
- No additional p -y curves to be computed at user - specified depths
Page 1
Solution Control Parameters:
30HEIGHTSCI3- #11.lpo
- Number of pile increments = 50
- Maximum number of iterations allowed = 100
- Deflection tolerance for convergence = 1.0000E -05 in
- Maximum allowable deflection = 1.0000E +02 in
Printing Options:
- values of pile -head deflection, bending moment, shear force, and
soil reaction are printed for full length of pile.
- Printing Increment (spacing of output points) = 1
------------------------------------------------------------------------------
Pile structural Properties and Geometry
------------------------------------------------------------------------ - - - - --
Pile Length = 300.00 in
Depth of ground surface below top of pile = .00 in
slope angle of ground surface = .00 deg.
structural properties of pile defined using 2 points
Point Depth
Pile
Moment of
Pile
Modulus of
X
Diameter
Inertia
Area
Elasticity
in
in
in * *4
Sq.in
lbs /Sq.in
- - - -- --- - - - - --
1 0.0000
----- - - - - --
36.000
---- - - - - --
82448.0000
---- - - - - --
1018.0000
----- - - - - --
3604997.000
2 300.0000
36.000
82448.0000
1018.0000
3604997.000
Please note that because this analysis makes computations of ultimate
moment capacity and pile response using nonlinear bending stiffness
that the above values of moment of inertia and modulus of are not used
for any computations other than total stress due to combined axial
loading and bending.
------------------------------------------------------------------------------
Soil and Rock Layering Information
------------------------------------------------------------------------ - - - - --
The soil profile is modelled using 2 layers
Layer 1 is sand, p -y
criteria by API RP -2A, 1987
Distance from top of
pile to top of layer =
.000
in
Distance from top of
ppile to bottom of layer =
144.000
in
p -y subgrade modulus
k for top of soil layer =
300.000
lbs /in * *3
p -y subgrade modulus
k for bottom of layer =
300.000
lbs /in * *3
Layer 2 is sand, p -y
criteria by API RP -2A, 1987
Distance from top of
pile to top of layer =
144.000
in
Distance from top of
ppile to bottom of layer =
300.000
in
p -y subgrade modulus
k for top of soil layer =
150.000
lbs /in * *3
p -y subgrade modulus
k for bottom of layer =
150.000
lbs /in * *3
(Depth of lowest layer extends .00 in below pile tip)
------------------------------------------------------------------------------
Effective unit weight of Soil vs. Depth
------------------------------------------------------------------------ - - - - --
Distribution of effective unit weight of soil with depth
Page 2
30HEIGHTSCI3- #11.lpo
is defined using 4 points
Point Depth x Eff. unit weight
No. in lbs /in * *3
- - - -- ---- - - - - -- ----------------
1 .00 .07200
2 144.00 .07200
3 144.00 .07200
4 300.00 .07200
------------------------------------------------------------------------------
Shear Strength of Soils
------------------------------------------------------------------------ - - - - --
Distribution of shear strength parameters with depth
defined using 4 points
Point
Depth x
Cohesion c
Angle of Friction E50 or RQD
No.
in
lbs /in * *2
Deg. k_rm %
- - - --
1
-- - - - - --
.000
---- - - - - --
.00000
------------ - - - - -- - - - - -- - - - - --
38.00 - - - - -- - - - - --
2
144.000
.00000
38.00 - - - - -- - - - - --
3
144.000
.00000
30.00 - - - - -- - - - - --
4
300.000
.00000
30.00 - - - - -- - - - - --
Notes:
(1) Cohesion = uniaxial compressive strength for rock materials.
(2) values of E50 are reported for clay strata.
(3) Default values will be generated for E50 when input values are 0.
(4) RQD and k_rm are reported only for weak rock strata.
------------------------------------------------------------------------------
Loading Type
------------------------------------------------------------------------ - - - - --
Static loading criteria was used for computation of p -y curves
------------------------------------------------------------------------------
Pile -head Loading and Pile -head Fixity Conditions
------------------------------------------------------------------------ - - - - --
Number of loads specified = 1
Load Case Number 1
Pile -head boundary conditions are Shear and Moment (BC Type 1)
Shear force at pile head = 81000.000 lbs
Bending moment at pile head = 9720000.000 in -lbs
Axial load at pile head = 30000.000 lbs
Non -zero moment at pile head for this load case indicates the pile -head
may rotate under the applied pile -head loading, but is not a free -head
(zero moment) condition.
Page 3
30HEIGHTSCI3- #11.lpo
------------------------------------------------------------------------------
Computations of ultimate Moment Capacity and Nonlinear Bending Stiffness
------------------------------------------------------------------------ - - - - --
Number of pile sections = 1
Pile Section No. 1
The sectional shape is a circular drilled shaft (bored pile).
Outside Diameter
Material Properties:
36.0000 In
Compressive Strength of Concrete = 4.000 Kip /In * *2
Yield Stress of Reinforcement = 60. Kip /In * *2
Modulus of Elasticity of Reinforcement = 29000. Kip /In * *2
Number of Reinforcing Bars = 13
Area of Single Bar = 1.56000 In * *2
Number of Rows of Reinforcing Bars = 13
Cover Thickness (edge to bar center) = 3.000 In
ultimate Axial Squash Load Capacity = 4608.63 Kip
Distribution and Area of Steel Reinforcement
ROW
Number
1
2
4
6
7
8
10
11
12
13
Area of
Reinforcement
In * *2
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
Axial Thrust Force =
Distance to
Centroidal Axis
In
---------------
14.8906
14.0252
12.3448
9.9468
6.9708
3.5897
.0000
- 3.5897
- 6.9708
- 9.9468
- 12.3448
- 14.0252
- 14.8906
30000.00 lbs
Bending
Bending
Bending
Maximum
Neutral Axis
Moment
stiffness
Curvature
Strain
Position
in -lbs
lb -in2
rad /in
in /in
inches
------- - - - - -- -------
365529.073
- - - - --
3.65529E +11
------- - - - - -- -------
.00000100
- - - - --
.00002510
------- - - - - --
25.102
1808877.322
3.61775E +11
.00000500
.00009743
19.486
1808877.322
2.00986E +11
.00000900
.00011727
13.030
1813772.136
1.39521E +11
.00001300
.00016197
12.459
2301705.531
1.35394E +11
.00001700
.00020652
12.148
2787942.854
1.32759E +11
.00002100
.00025147
11.975
3271802.247
1.30872E +11
.00002500
.00029622
11.849
3753703.921
1.29438E +11
.00002900
.00034113
11.763
4233533.689
1.28289E +11
.00003300
.00038620
11.703
Page 4
15884.901
------------------------------------------------------------------------------
Computed values of Load Distribution and Deflection
for Lateral Loading for Load Case Number 1
------------------------------------------------------------------------ - - - - --
Pile -head boundary conditions are Shear and Moment (BC Typpe 1)
Specified shear force at pile head = 81000.000 lbs
Specified bending moment at pile head = 9720000.000 in -lbs
specified axial load at pile head = 30000.000 lbs
Non -zero moment for this load case indicates the pile -head may rotate under
the applied pile -head loading, but is not a free -head (zero moment )condition.
Depth Deflect. Moment Shear Slope Total FIX. Rig. Soil Res
X y M v S Stress EI p
in in lbs -in lbs Rad. lbs /in * *2 lbs -in * *2 lbs /in
-- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - --
0.000 1.021 9.72E +06 8.10E +04 - .014591 2151.5 1.21E +11 0.000
6.000 .934612 1.02E +07 8.04E +04 - .014096 2258.2 1.21E +11 - 205.567
12.000 .851556 1.07E +07 7.84E +04 - .013577 2363.2 1.21E +11 - 446.852
18.000 .771683 1.12E +07 7.49E +04 - .013033 2464.7 1.20E +11 - 715.820
24.000 .695155 1.16E +07 6.98E +04 - .012464 2560.6 1.20E +11 - 1004.386
30.000 .622116 1.20E +07 6.29E +04 - .011869 2648.5 1.18E +11 - 1304.281
36.000 .552727 1.24E +07 5.41E +04 - .011240 2726.2 1.14E +11 - 1606.753
42.000 .487231 1.26E +07 4.36E +04 - .010575 2791.2 1.11E +11 - 1902.058
48.000 .425831 1.29E +07 3.13E +04 - .009879 2841.2 1.09E +11 - 2178.845
54.000 .368682 1.30E +07 1.75E +04 - .009162 2874.1 1.08E +11 - 2423.678
60.000 .315887 1.31E +07 2407.2 - .008433 2887.9 1.07E +11 - 2621.109
Page 5
30HEIGHTSCI3- #11.lpo
4711348.786
1.27334E +11
.00003700
.00043144
11.660
5187051.807
1.26513E +11
.00004100
.00047684
11.630
5660697.734
1.25793E +11
.00004500
.00052242
11.609
6132126.527
1.25145E +11
.00004900
.00056817
11.595
6601361.133
1.24554E +11
.00005300
.00061410
11.587
7068211.573
1.24004E +11
.00005700
.00066020
11.582
7533068.033
1.23493E +11
.00006100
.00070651
11.582
7995312.769
1.23005E +11
.00006500
.00075299
11.584
8455487.607
1.22543E +11
.00006900
.00079968
11.590
8913107.167
1.22097E +11
.00007300
.00084656
11.597
9368294.706
1.21666E +11
.00007700
.00089365
11.606
9820968.756
1.21247E +11
.00008100
.00094094
11.617
10271009.569
1.20835E +11
.00008500
.00098843
11.629
10718667.107
1.20434E +11
.00008900
.00103617
11.642
11163578.909
1.20038E +11
.00009300
.00108412
11.657
11605755.328
1.19647E +11
.00009700
.00113229
11.673
11974550.921
1.18560E +11
.00010100
.00117812
11.665
13561696.842
1.03524E +11
.00013100
.00148359
11.325
14398297.119
8.94304E +10
.00016100
.00175666
10.911
14966770.583
7.83601E +10
.00019100
.00202251
10.589
15278657.456
6.91342E +10
.00022100
.00226904
10.267
15574986.286
6.20517E +10
.00025100
.00252507
10.060
15749169.025
5.60469E +10
.00028100
.00276119
9.82630920
15882686.227
5.10697E +10
.00031100
.00299482
9.62965393
15991849.331
4.68969E +10
.00034100
.00324999
9.53077698
16079816.350
4.33418E +10
.00037100
.00349740
9.42695618
16144487.592
4.02606E +10
.00040100
.00375785
9.37120056
16144487.592
3.74582E +10
.00043100
.00401070
9.30555725
unfactored (Nominal) Moment
Capacity at a
Concrete strain
of 0.003 =
In -Kip
15884.901
------------------------------------------------------------------------------
Computed values of Load Distribution and Deflection
for Lateral Loading for Load Case Number 1
------------------------------------------------------------------------ - - - - --
Pile -head boundary conditions are Shear and Moment (BC Typpe 1)
Specified shear force at pile head = 81000.000 lbs
Specified bending moment at pile head = 9720000.000 in -lbs
specified axial load at pile head = 30000.000 lbs
Non -zero moment for this load case indicates the pile -head may rotate under
the applied pile -head loading, but is not a free -head (zero moment )condition.
Depth Deflect. Moment Shear Slope Total FIX. Rig. Soil Res
X y M v S Stress EI p
in in lbs -in lbs Rad. lbs /in * *2 lbs -in * *2 lbs /in
-- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - -- --- - - - - --
0.000 1.021 9.72E +06 8.10E +04 - .014591 2151.5 1.21E +11 0.000
6.000 .934612 1.02E +07 8.04E +04 - .014096 2258.2 1.21E +11 - 205.567
12.000 .851556 1.07E +07 7.84E +04 - .013577 2363.2 1.21E +11 - 446.852
18.000 .771683 1.12E +07 7.49E +04 - .013033 2464.7 1.20E +11 - 715.820
24.000 .695155 1.16E +07 6.98E +04 - .012464 2560.6 1.20E +11 - 1004.386
30.000 .622116 1.20E +07 6.29E +04 - .011869 2648.5 1.18E +11 - 1304.281
36.000 .552727 1.24E +07 5.41E +04 - .011240 2726.2 1.14E +11 - 1606.753
42.000 .487231 1.26E +07 4.36E +04 - .010575 2791.2 1.11E +11 - 1902.058
48.000 .425831 1.29E +07 3.13E +04 - .009879 2841.2 1.09E +11 - 2178.845
54.000 .368682 1.30E +07 1.75E +04 - .009162 2874.1 1.08E +11 - 2423.678
60.000 .315887 1.31E +07 2407.2 - .008433 2887.9 1.07E +11 - 2621.109
Page 5
!1
Output verification:
Computed forces and moments are within specified convergence limits.
output summary for Load Case No. 1:
Pile -head deflection
Computed slope at pile head
Maximum bending moment
Maximum shear force
Depth of maximum bending moment
Depth of maximum shear force
Number of iterations
Number of zero deflection points
= 1.02070781
in
- .01459055
30HEIGHTSCI3- #11.lpo
= 13092818.824
1 bs -i n
66.000
.267489
1.31E +07
- 1.37E +04
- .007702
2881.1
1.07E +11
- 2754.647
72.000
.223467
1.29E +07
- 3.04E +04
- .006980
2852.5
1.09E +11
- 2808.766
78.000
.183731
1.27E +07
- 4.72E +04
- .006279
2801.9
1.11E +11
- 2771.560
84.000
.148125
1.24E +07
- 6.34E +04
- .005609
2729.5
1.14E +11
- 2637.201
90.000
.116421
1.19E +07
- 7.85E +04
- .004982
2636.3
1.19E +11
- 2407.142
96.000
.088341
1.14E +07
- 9.21E +04
- .004394
2524.2
1.20E +11
- 2115.962
102.000
.063694
1.08E +07
- 1.04E +05
- .003838
2395.4
1.20E +11
- 1774.509
108.000
.042289
1.02E +07
- 1.13E +05
- .003315
2252.7
1.21E +11
- 1317.091
114.000
.023917
9.48E +06
- 1.19E +05
- .002828
2099.6
1.22E +11
- 808.295
120.000
.008353
8.75E +06
- 1.23E +05
- .002379
1940.1
1.22E +11
- 300.289
126.000
- .004634
8.01E +06
- 1.23E +05
- .001969
1778.3
1.23E +11
175.114
132.000
- .015277
7.28E +06
- 1.21E +05
- .001597
1617.8
1.24E +11
602.613
138.000
- .023803
6.56E +06
- 1.16E +05
- .001263
1462.0
1.25E +11
976.835
144.000
- .030434
5.88E +06
- 1.11E +05
- 9.64E -04
1313.9
1.25E +11
723.598
150.000
- .035376
5.23E +06
- 1.06E +05
- 7.00E -04
1171.4
1.26E +11
866.167
156.000
- .038830
4.61E +06
- 1.01E +05
- 4.67E -04
1035.8
1.28E +11
983.430
162.000
- .040982
4.02E +06
- 9.44E +04
- 2.65E -04
907.9
1.29E +11
1073.390
168.000
- .042009
3.48E +06
- 8.78E +04
- 9.11E -05
788.4
1.30E +11
1137.554
174.000
- .042075
2.97E +06
- 8.09E +04
5.65E -05
677.9
1.32E +11
1177.465
180.000
- .041330
2.51E +06
- 7.37E +04
1.80E -04
576.5
1.34E +11
1194.725
186.000
- .039914
2.08E +06
- 6.66E +04
2.82E -04
484.6
1.37E +11
1191.007
192.000
- .037949
1.71E +06
- 5.95E +04
3.42E -04
402.1
3.62E +11
1168.066
198.000
- .035814
1.37E +06
- 5.26E +04
3.67E -04
328.7
3.62E +11
1136.036
204.000
- .033544
1.08E +06
- 4.59E +04
3.87E -04
264.2
3.62E +11
1095.503
210.000
- .031166
8.20E +05
- 3.95E +04
4.03E -04
208.4
3.63E +11
1047.057
216.000
- .028707
6.01E +05
- 3.34E +04
4.15E -04
160.8
3.64E +11
991.275
222.000
- .026189
4.19E +05
- 2.76E +04
4.23E -04
121.0
3.65E +11
928.711
228.000
- .023629
2.70E +05
- 2.22E +04
4.29E -04
88.4274
3.66E +11
859.875
234.000
- .021043
1.52E +05
- 1.73E +04
4.32E -04
62.6597
3.66E +11
785.225
240.000
- .018441
6.23E +04
- 1.28E +04
4.34E -04
43.0633
3.66E +11
705.156
246.000
- .015834
- 2109.0
- 8856.1
4.35E -04
29.9300
3.66E +11
619.998
252.000
- .013227
- 4.42E +04
- 5406.0
4.34E -04
39.1113
3.66E +11
530.016
258.000
- .010624
- 6.71E +04
- 2509.8
4.33E -04
44.1270
3.66E +11
435.406
264.000
- .008027
- 7.44E +04
-194.6
4.32E -04
45.7205
3.66E +11
336.300
270.000
- .005439
- 6.96E +04
1512.6
4.31E -04
44.6708
3.66E +11
232.770
276.000
- .002856
- 5.64E +04
2585.4
4.30E -04
41.7917
3.66E +11
124.838
282.000
- 2.80E -04
- 3.88E +04
2997.4
4.29E -04
37.9313
3.66E +11
12.484
288.000
.002293
- 2.06E +04
2721.8
4.29E -04
33.9728
3.66E +11
- 104.335
294.000
.004864
- 6251.4
1731.8
4.28E -04
30.8343
3.66E +11
- 225.676
300.000
.007434
0.0
0.0
4.28E -04
29.4695
3.66E +11
- 351.581
Please note
that because this
analysis
makes computations
of ultimate moment
capacity
and pile response using
nonlinear bending
stiffness
that the above
values of
total stress due to
combined
axial stress
and bending
may
not be
representative of actual conditions.
Output verification:
Computed forces and moments are within specified convergence limits.
output summary for Load Case No. 1:
Pile -head deflection
Computed slope at pile head
Maximum bending moment
Maximum shear force
Depth of maximum bending moment
Depth of maximum shear force
Number of iterations
Number of zero deflection points
= 1.02070781
in
- .01459055
= 13092818.824
1 bs -i n
_ - 123103.527
lbs C2 «-
= 60.000
in
= 126.000
in
= 22
= 2
Page 6
30HEIGHTSCI3- #11.lpo
------------------------------------------------------------------------------
Summary of Pile -head Response
------------------------------------------------------------------------ - - - - --
Definition of symbols for pile -head boundary conditions:
y = pile -head displacment, in
M = pile -head moment, lbs -in
v = pile -head shear force, lbs
S = pile -head slope, radians
R = rotational stiffness of pile -head, in- lbs /rad
BC Boundary
Boundary
Axial
Pile Head
Maximum Maximum
Type Condition
Condition
Load
Deflection
Moment Shear
1
2
lbs
in
in -lbs lbs
- - -- ------ - - - - --
1 v= 81000.000
------ - - - - --
M= 9.72E +06
----- - - - - --
30000.0000
----- - - - - --
1.0207
----- - - - - -- ----- - - - - --
1.309E +07 - 123103.5272
------------------------------------------------------------------------------
Pile -head Deflection vs. Pile Length
------------------------------------------------------------------------ - - - - --
Boundary Condition Type 1, shear and Moment
Shear =
81000. lbs
Moment =
9720000.
in -lbs
Axial Load =
30000.
lbs
Pile
Pile Head
Maximum
Maximum
Length
Deflection
Moment
Shear
in
in
in -lbs
lbs
----- - - - - --
300.000
------ - - - - --
1.02070781
------ - - - - --
13092818.824
------ - - - - --
- 123103.527
285.000
1.01912545
13089370.969
- 124923.403
270.000
1.01890778
13088078.258
- 124596.013
255.000
1.01878943
13090464.902
- 124950.220
240.000
1.02363726
13086723.734
- 127392.275
225.000
1.03848509
13082455.857
- 132146.595
210.000
1.07734393
13080601.352
- 141101.841
195.000
1.18504140
13082154.704
- 157640.844
180.000
1.58462273
13088941.753
- 189588.719
The analysis ended normally.
Page 7
(OGGINS & SONS, .�� Name
PH. (303) 791 -9911 FAX (303) 791 -0967 �� J ����
CAISSON DRILLING PROJECT: PROJECT NO.:
EARTH RETENTION
TIE BACK ANCHORS SUBJECT: DATE: `� 3
Ey
�C 2 d�
Z 2
V G = 2 J �} " f o� l «} 2 ,
U l'.)- - 2 IL t =okxn—_ — co
vS _ 2S
.�S
3 Q o 0Q 47 _ '
O V 00 r� Z- ) 2 (rs . 7 S 1 u— ) h
11 t
00 tf... 4- t
QC
(2 A�o
(OGGINS & SONS, ''�� Name
PH. (303) 791 -9911 FAX (303) 791 -0967
CAISSON DRILLING PROJECT:
EARTH RETENTION
TIE BACK ANCHORS SUBJECT:
;k-A T>j . o C.,
'1
LP- P,
Y ij
1?.'7
PROJECT NO.:
DATE: C J 4 u
j b
S °�" °I t,3ol
- 4 , --:"
< L 7,
A "Z--
Computed by LPILE Plus for Windows. Ver. 5.0, (c) 2002 by ENSOFr, Inc.
-0.1
O
N
O
O
O
r
N
t �
a+
Q
d
V
r
CO
r
CO
O
N
N
N
N
04
Lateral Deflection (in)
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
o USE 30 H (34 FT) - 6 FT SPACING
4 . 2.._.
N
N
N
r
O
r
r
C
C N
O
V
d
d
D
d
2
d
'a
CR
0
0
v
0
N
O
O
50
100
0
v USE 30 H (34 FT) - 6 FT SPACING
150 200 250
300 350 400
Pile Length (in)
r —,>
O
N
co
O
O
v N
�F+
Q.
d
r
r
co
r
O
N
N
N
N
co
04
Unfactored Bending Moment (in -kips)
0 2000 4000 6000 8000 1E4 1.2E4 1.4E4 1.6E4 1.8114
USE 30H - 6 FT SPACING
� : 4 , �-
.0 00 :i
MKO
v
0
0
N
s
a
m
Nt
r-
CD
00
0
N
N
N
N
cfl
N
Shear Force (kips)
-60 -40 -20 0 20 40 60 80 100
v USE 30 H - 6 FT SPACING
C(
u
r
v Thrust = 30 kips
00
w
ca
N
00
w
Lq
LO
00
w
LO
00
w
v
N co
w
C �
N
Q
Y
W Lq
vi M
N
d
C
C
M
w
d LO
m N
00
w
N
M
w
co
w
ti
w
LO
0
2000 4000 6000 8000 1 E4 1.2E4 1.4E4 1.6E4 1.8E4 2E4 2.2E4
Bending Moment (in -kips)
34HEIGHTSC.Ipo
LPILE Plus for Windows, version 5.0 (5.0.1)
Analysis of Individual Piles and Drilled Shafts
Subjected to Lateral Loading using the p -y Method
(c) Copyright ENSOFT, Inc., 1985 -2004
All Rights Reserved
This program is licensed to:
JOHN H. HART
COGGINS
Path
to
file locations:
C: \Documents and Settings \COGGINS AND SONS \My
Documents \2007JOBS \MOUNTAINVIEW\
Name
of
input data file:
34HEIGHTSC.lpd
Name
of
output file:
34HEIGHTSC.lpo
Name
of
plot output file:
34HEIGHTSC.Ipp
Name
of
runtime file:
34HEIGHTSC.lpr
------------------------------------------------------------------------------
Time and Date of Analysis
------------------------------------------------------------------------ - - - - --
Date: September 5, 2007 Time: 14:13:41
------------------------------------------------------------------------------
Problem Title
------------------------------------------------------------------------ - - - - --
MOUNTAIN VIEW - 34 HT
------------------------------------------------------------------------------
Program Options
------------------------------------------------------------------------ - - - - --
Units used in Computations - us Customary Units, inches, pounds
Basic Program Options:
Analysis Type 3:
- Computation of Nonlinear Bending Stiffness and ultimate Bending Moment
Capacity with Pile Response Computed using Nonlinear EI
Computation Options:
- Only internally - generated p -y curves used in analysis
- Analysis does not use p -y multipliers (individual pile or shaft action only)
- Analysis assumes no shear resistance at pile tip
- Analysis includes automatic computation of pile -top deflection vs.
pile embedment length
- No computation of foundation stiffness matrix elements
- output pile response for full length of pile
- Analysis assumes no soil movements acting on pile
- No additional p -y curves to be computed at user - specified depths
Page 1
Solution Control Parameters:
34HEIGHTSC.Ipo
- Number of pile increments = 52
- Maximum number of iterations allowed = 100
- Deflection tolerance for convergence = 1.0000E -05 in
- Maximum allowable deflection = 1.0000E +02 in
Printing Options:
- values of pile -head deflection, bending moment, shear force, and
soil reaction are printed for full length of pile.
- Printing Increment (spacing of output points) = 1
------------------------------------------------------------------------------
Pile Structural Properties and Geometry
------------------------------------------------------------------------ - - - - --
Pile Length = 312.00 in
Depth of ground surface below top of pile = .00 in
Slope angle of ground surface = .00 deg.
Structural properties of pile defined using 2 points
Point Depth
Pile
Moment of
Pile
Modulus of
X
Diameter
Inertia
Area
Elasticity
in
in
in * *4
Sq.in
lbs /Sq.in
- - - -- --- - - - - --
1 0.0000
----- - - - - --
42.000
---- - - - - --
152745.0000
---- - - - - --
1385.0000
----- - - - - --
3604997.000
2 312.0000
42.000
152745.0000
1385.0000
3604997.000
Please note that because this analysis makes computations of ultimate
moment capacity and pile response using nonlinear bending stiffness
that the above values of moment of inertia and modulus of are not used
for any computations other than total stress due to combined axial
loading and bending.
------------------------------------------------------------------------------
Soil and Rock Layering Information
------------------------------------------------------------------------ - - - - --
The soil profile is modelled using 2 layers
Layer 1 is sand, p -y
criteria by API RP -2A, 1987
Distance from top of
pile
to top of layer =
.000
in
Distance from top of
pile
p
to bottom of layer =
144.000
in
p -y subgrade modulus
for
top of soil layer =
300.000
lbs /in * *3
p -y subgrade modulus
k for
bottom of layer =
300.000
lbs /in * *3
Layer 2 is sand, p -y
criteria
by API RP -2A, 1987
Distance from top of
pile
to top of layer =
144.000
in
Distance from top of
pile
p
to bottom of layer =
312.000
in
p -y subgrade modulus
for
top of soil layer =
150.000
lbs /in * *3
p -y subgrade modulus
k for
bottom of layer =
150.000
lbs /in * *3
(Depth of lowest layer extends .00 in below pile tip)
------------------------------------------------------------------------------
Effective unit weight of soil vs. Depth
------------------------------------------------------------------------ - - - - --
Distribution of effective unit weight of soil with depth
Page 2
is defined using 4 points
34HEIGHTSC.lpo
Point
Depth x
Eff. unit weight
No.
in
lbs /in * *3
- - - --
1
---- - - - - --
.00
----------------
.07200
2
144.00
.07200
3
144.00
.07200
4
312.00
.07200
------------------------------------------------------------------------------
Shear Strength of Soils
------------------------------------------------------------------------ - - - - --
Distribution of shear strength parameters with depth
defined using 4 points
Point
Depth x
Cohesion c
Angle of Friction E50 or RQD
No.
in
lbs /in * *2
Deg. k_rm %
- - - - -- - - - - --
- - - --
1
-- - - - - --
.000
---- - - - - --
.00000
------------ - - - - --
38.00 - - - - -- - - - - --
2
144.000
.00000
38.00 - - - - -- - - - - --
3
144.000
.00000
30.00 - - - - -- - - - - --
4
312.000
.00000
30.00 - - - - -- - - - - --
Notes:
(1) Cohesion = uniaxial compressive strength for rock materials.
(2) values of E50 are reported for clay strata.
(3) Default values will be generated for E50 when input values are 0.
(4) RQD and k_rm are reported only for weak rock strata.
------------------------------------------------------------------------------
Loading Type
------------------------------------------------------------------------ - - - - --
Static loading criteria was used for computation of p -y curves
------------------------------------------------------------------------------
Pile -head Loading and Pile -head Fixity Conditions
------------------------------------------------------------------------ - - - - --
Number of loads specified = 1
Load Case Number 1
Pile -head boundary conditions are shear and Moment (BC Type 1)
Shear force at pile head = 104000.000 lbs
Bending moment at pile head = 14100000.000 in -lbs
Axial load at pile head = 30000.000 lbs
Non -zero moment at pile head for this load case indicates the pile -head
may rotate under the applied pile -head loading, but is not a free -head
(zero moment) condition.
Page 3
34HEIGHT5C.Ipo
------------------------------------------------------------------------------
Computations of ultimate Moment Capacity and Nonlinear Bending stiffness
------------------------------------------------------------------------ - - - - --
Number of pile sections = 1
Pile Section No. 1
The sectional shape is a circular drilled shaft (bored pile).
outside Diameter
Material Properties:
Compressive Strength of Concrete
Yield stress of Reinforcement
Modulus of Elasticity of Reinforcement
Number of Reinforcing Bars
Area of single Bar
Number of Rows of Reinforcing Bars
Cover Thickness (edge to bar center)
42.0000 In
4.000 Kip /In * *2
60. Kip /In * *2
29000. Kip /In * *2
15
1.56000 In * *2
15
3.000 In
ultimate Axial Squash Load Capacity = 6034.94 Kip
Distribution and Area of Steel Reinforcement
ROW
Number
1
3
4
5
6
7
8
10
11
12
13
14
15
Area of
Reinforcement
In* *2
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
1.560000
Axial Thrust Force =
Distance to
Centroidal Axis
In
17.9014
17.1190
15.5885
13.3766
10.5801
7.3213
3.7424
.0000
- 3.7424
- 7.3213
- 10.5801
- 13.3766
- 15.5885
- 17.1190
- 17.9014
30000.00 lbs
Bending
Bending
Bending
Maximum
Neutral Axis
Moment
stiffness
Curvature
Strain
Position
in -lbs
lb -in2
rad /in
in /in
inches
- - - - --
------- - - - - --
664453.460
------- - - - - --
6.64453E +11
------- - - - - --
.00000100
------- - - - - --
.00002636
-------
26.358
3280808.326
6.56162E +11
.00000500
.00011073
22.147
3280808.326
3.64534E +11
.00000900
.00012596
13.996
3280808.326
2.52370E +11
.00001300
.00017566
13.513
3768552.680
2.21680E +11
.00001700
.00022584
13.284
4583037.764
2.18240E +11
.00002100
.00027583
13.135
5393909.901
2.15756E +11
.00002500
.00032603
13.041
Page
4
s4, k0
6201093.154
7004684.346
7804303.921
8600177.606
9392102.280
10180116.865
10963881.289
11743472.802
12518809.609
13289944.056
14056548.399
14818473.181
15575812.735
16294141.893
16841658.524
17302433.851
17691334.828
18050444.971
18336187.222
19927938.915
20830014.176
21352671.317
21754099.678
22004510.642
22252568.104
22393136.844
22452666.655
22489854.603
22489854.603
2.13831E +11
2.12263E +11
2.10927E +11
2.09760E +11
2.08713E +11
2.07757E +11
2.06866E +11
2.06026E +11
2.05226E +11
2.04461E +11
2.03718E +11
2.02993E +11
2.02283E +11
2.01162E +11
1.98137E +11
1.94409E +11
1.90229E +11
1.86087E +11
1.81546E +11
1.52122E +11
1.29379E +11
1.11794E +11
9.84348E +10
8.76674E +10
7.91906E +10
7.20037E +10
6.58436E +10
6.06196E +10
5.60844E +10
34HEIGHTSC
.00002900
.00003300
.00003700
.00004100
.00004500
.00004900
.00005300
.00005700
.00006100
.00006500
.00006900
.00007300
.00007700
.00008100
.00008500
.00008900
.00009300
.00009700
.00010100
.00013100
.00016100
.00019100
.00022100
.00025100
.00028100
.00031100
.00034100
.00037100
.00040100
1po
.00037644
.00042707
.00047791
.00052899
.00058029
.00063184
.00068363
.00073566
.00078795
.00084051
.00089334
.00094644
.00099983
.00105268
.00110175
.00114886
.00119433
.00123917
.00128205
.00158990
.00187682
.00214471
.00241352
.00266763
.00293650
.00319719
.00345282
.00371997
.00398968
12.981
12.942
12.917
12.902
12.895
12.895
12.899
12.906
12.917
12.931
12.947
12.965
12.985
12.996
12.962
12.909
12.842
12.775
12.694
12.137
11.657
11.229
10.921
10.628
10.450
10.280
10.126
10.027
9.94933319
unfactored (Nominal) Moment Capacity at a Concrete Strain of 0.003 =
In -Kip
22286.810
------------------------------------------------------------------------------
Computed values of Load Distribution and Deflection
for Lateral Loading for Load Case Number 1
------------------------------------------------------------------------ - - - - --
Pile -head boundary conditions are shear and Moment (BC Type 1)
Specified shear force at pile head = 104000.000 lbs
Specified bending moment at pile head = 14100000.000 in -lbs
Specified axial load at pile head = 30000.000 lbs
Non -zero moment for this load case indicates the pile -head may rotate under
the applied pile -head loading, but is not a free -head (zero moment )condition.
Depth Deflect
X y
in in
0.000
1.011
6.000
.931246
12.000
.854075
18.000
.779625
24.000
.708020
30.000
.639389
36.000
.573881
42.000
.511656
48.000
.452875
54.000
.397689
Moment
M
lbs -in
1.41E +07
1.47E +07
1.53E +07
1.59E +07
1.65E +07
1.70E +07
1.75E +07
1.79E +07
1.83E +07
1.85E +07
Shear
v
lbs
1.04E +05
1.03E +05
1.01E +05
9.71E +04
9.12E +04
8.34E +04
7.34E +04
6.14E +04
4.73E +04
3.14E +04
Slope
S
Rad.
- .013505
- .013079
- .012635
- .012171
- .011686
- .011178
- .010644
- .010084
- .009497
- .008885
Total
stress
lbs /in * *2
1960.2
2046.3
2131.2
2213.6
2292.0
2364.7
2430.1
2486.4
2531.9
2564.9
FIX. Rig. Soil Res
EI p
lbs -in * *2 lbs /in
2.03E +11
2.03E +11
2.03E +11
2.02E +11
2.00E +11
1.96E +11
1.92E +11
1.87E +11
1.83E +11
1.78E +11
0.000
- 236.597
- 510.054
- 813.457
- 1139.768
- 1481.588
- 1830.715
- 2177.489
- 2510.066
- 2813.917
Page 5
GA, 11
Output verification:
computed forces and moments are within specified convergence limits.
Output Summary for Load case No. 1:
Pile -head deflection = 1.01102679
computed slope at pile head = - .01350515
Maximum bending moment = 18666051.557
Maximum shear force = - 155334.894
Depth of maximum bending moment = 66.000
Depth of maximum shear force = 132.000
Page 6
in
1 bs -i n < m- - _ °
lbs
in °t om
in
34HEIGHTSC.Ipo
60.000
.346250
1.86E +07
1.37E +04
- .008253
2584.0
1.75E +11
- 3071.976
66.000
.298652
1.87E +07
- 5311.1
- .007611
2587.9
1.74E +11
- 3265.791
72.000
.254913
1.86E +07
- 2.52E +04
- .006973
2575.7
1.76E +11
- 3377.684
78.000
.214973
1.84E +07
- 4.56E +04
- .006352
2546.6
1.81E +11
- 3393.461
84.000
.178689
1.80E +07
- 6.56E +04
- .005757
2500.8
1.86E +11
- 3304.703
90.000
.145889
1.76E +07
- 8.49E +04
- .005191
2438.6
1.91E +11
- 3110.369
96.000
.116397
1.70E +07
- 1.03E +05
- .004656
2361.0
1.97E +11
- 2817.148
102.000
.090018
1.63E +07
- 1.18E +05
- .004152
2269.5
2.01E +11
- 2438.208
108.000
.066571
1.56E +07
- 1.32E +05
- .003677
2165.8
2.02E +11
- 1991.529
114.000
.045899
1.48E +07
- 1.42E +05
- .003227
2052.3
2.03E +11
- 1508.760
120.000
.027846
1.39E +07
- 1.50E +05
- .002804
1931.3
2.04E +11
- 988.732
126.000
.012246
1.30E +07
- 1.54E +05
- .002410
1805.4
2.05E +11
- 461.728
132.000
- .001074
1.20E +07
- 1.55E +05
- .002044
1677.2
2.06E +11
42.514
138.000
- .012285
1.11E +07
- 1.54E +05
- .001707
1549.3
2.07E +11
507.499
144.000
- .021562
1.02E +07
- 1.51E +05
- .001399
1423.8
2.08E +11
511.756
150.000
- .029071
9.30E +06
- 1.47E +05
- .001118
1300.8
2.09E +11
712.027
156.000
- .034976
8.44E +06
- 1.42E +05
- 8.64E -04
1181.4
2.10E +11
885.179
162.000
- .039435
7.60E +06
- 1.36E +05
- 6.35E -04
1066.3
2.11E +11
1030.732
168.000
- .042600
6.80E +06
- 1.30E +05
- 4.31E -04
956.3
2.13E +11
1149.558
174.000
- .044613
6.04E +06
- 1.23E +05
- 2.51E -04
852.1
2.14E +11
1242.614
180.000
- .045610
5.33E +06
- 1.15E +05
- 9.23E -05
753.9
2.16E +11
1310.891
186.000
- .045720
4.66E +06
- 1.07E +05
4.58E -05
662.3
2.18E +11
1355.422
192.000
- .045061
4.04E +06
- 9.88E +04
1.65E -04
577.3
2.20E +11
1377.291
198.000
- .043741
3.47E +06
- 9.06E +04
2.64E -04
499.2
2.38E +11
1377.651
204.000
- .041896
2.95E +06
- 8.24E +04
3.21E -04
427.9
6.56E +11
1358.849
210.000
- .039889
2.48E +06
- 7.43E +04
3.46E -04
363.3
6.57E +11
1331.187
216.000
- .037746
2.06E +06
- 6.64E +04
3.67E -04
305.3
6.57E +11
1295.064
222.000
- .035490
1.69E +06
- 5.88E +04
3.84E -04
253.7
6.58E +11
1250.897
228.000
- .033141
1.36E +06
- 5.14E +04
3.98E -04
208.3
6.59E +11
1199.105
234.000
- .030719
1.07E +06
- 4.44E +04
4.09E -04
168.8
6.60E +11
1140.104
240.000
- .028238
8.24E +05
- 3.78E +04
4.17E -04
135.0
6.62E +11
1074.296
246.000
- .025712
6.17E +05
- 3.15E +04
4.24E -04
106.5
6.64E +11
1002.057
252.000
- .023153
4.46E +05
- 2.58E +04
4.29E -04
82.9482
6.64E +11
923.735
258.000
- .020570
3.08E +05
- 2.05E +04
4.32E -04
63.9715
6.64E +11
839.635
264.000
- .017970
2.00E +05
- 1.57E +04
4.34E -04
49.1504
6.64E +11
750.026
270.000
- .015359
1.19E +05
- 1.15E +04
4.36E -04
38.0414
6.64E +11
655.131
276.000
- .012742
6.19E +04
- 7857.7
4.36E -04
30.1750
6.64E +11
555.137
282.000
- .010122
2.47E +04
- 4841.7
4.37E -04
25.0561
6.64E +11
450.185
288.000
- .007500
3671.2
- 2470.0
4.37E -04
22.1654
6.64E +11
340.379
294.000
- .004878
- 5100.9
-771.5
4.37E -04
22.3619
6.64E +11
225.790
300.000
- .002256
- 5744.6
225.2
4.37E -04
22.4504
6.64E +11
106.460
306.000
3.66E -04
- 2555.7
491.8
4.37E -04
22.0120
6.64E +11
- 17.590
312.000
.002987
0.0
0.0
4.37E -04
21.6606
6.64E +11
- 146.350
Please note
that because this
analysis
makes computations
of ultimate
moment
capacity
and pile
response using nonlinear bending
stiffness
that the
above
values of
total stress due to combined
axial stress and bending
may
not be
representative
of actual conditions.
Output verification:
computed forces and moments are within specified convergence limits.
Output Summary for Load case No. 1:
Pile -head deflection = 1.01102679
computed slope at pile head = - .01350515
Maximum bending moment = 18666051.557
Maximum shear force = - 155334.894
Depth of maximum bending moment = 66.000
Depth of maximum shear force = 132.000
Page 6
in
1 bs -i n < m- - _ °
lbs
in °t om
in
s4. ?-
34HEIGHTSC.lpo
Number of iterations = 28
Number of zero deflection points = 2
------------------------------------------------------------------------------
Summary of Pile -head Response
------------------------------------------------------------------------ - - - - --
Definition of symbols for pile -head boundary conditions:
y = pile -head displacment, in
M = pile -head moment, lbs -in
v = pile -head shear force, lbs
S = pile -head slope, radians
R = rotational stiffness of pile -head, in- lbs /rad
BC Boundary
Boundary
Axial
Pile Head
Maximum Maximum
Type Condition
Condition
Load
Deflection
Moment Shear
1
2
lbs
in
in -lbs lbs
- - -- ------ - - - - --
1 v= 1.04E +05
------ - - - - --
M= 1.41E +07
----- - - - - --
30000.0000
----- - - - - --
1.0110
----- - - - - -- ----- - - - - --
1.867E +07 - 155334.8942
------------------------------------------------------------------------------
Pile -head Deflection vs. Pile Length
------------------------------------------------------------------------ - - - - --
Boundary Condition Type 1, Shear and Moment
Shear =
104000. lbs
Moment =
14100000. in -lbs
Axial Load =
30000. lbs
Pile
Pile Head
Maximum
Maximum
Length
Deflection
Moment
Shear
in
in
in -lbs
lbs
--
----- - - - - --
312.000
------ - - - - --
1.01102679
------ - - - - --
18666051.557
------ - - - -
- 155334.894
296.400
1.00822572
18663067.259
- 157295.573
280.800
1.00905333
18666373.227
- 157836.834
265.200
1.01288802
18659135.415
- 160606.649
249.600
1.02237170
18655980.869
- 165506.024
234.000
1.04775353
18656650.589
- 174803.695
218.400
1.11040638
18653418.654
- 190541.268
202.800
1.27856012
18648538.867
- 216336.591
187.200
2.22166851
18662684.506
- 268915.376
The analysis ended normally.
Page 7
LA A
(OGGINS &SONS. "'C. Name _.
PH. (303) 791 -9911 FAX(303)797-0967
CAISSON DRILLING PROJECT: V�c�w :r, 1 =tom
EARTH RETENTION
TIEBACKANCHORS SUBJECT:
4 T:�" i G OCs :> E "_3
' L' L, = t S S'
PROJECT NO.:
DATE: "I t 3
v'l
AaoO (�� to �— V--
t4o iS
V z >
,S
{
}
f
Y (c i
4- C? �--
(OGGINS & SONS A C Name
PH. (303)791 -9911 FAX(303)791-0967 a J t 2 J
CAISSON DRILLING PROJECT:
EARTH RETENTION
TIEBACKANCHORS SUBJECT:
V S l S — �c l i Sr i%. e �. t .z ?^.:
V41 A
' t
PROJECT NO.:
DATE: °' 1 4-
o
COGGINS & SON Name S�.v
PH. (303),791-9917 FAX (303) 791-0967
CAISSON DRILLING PROJECT: PROJECT NO.:
EARTH RETENTION DATE:
TIEBACKANCHORS SUBJECT:
J6
Vol
�� _ G ^,goo �} � __-- _� � (o- ` � _ __
qJ = -A -, ,
c-
(OGGINS & SONS. k" ' : C Name r
PH. (303) 791 -9911 FAX(303)797-0967 o J J
CAISSON DRILLING PROJECT:
EARTH RETENTION
TIE BACK ANCHORS SUBJECT:
Sc IA
USG w4 K w 4 4
CAS G Vl,t o M t
w!� w � y
x,
e
C-A Lc-
34
V,) 4
I(O .V
PROJECT NO.:
DATE: c-t 1 4 / u
COGGINS & SONS, INC., SHORING DESIGN REFERENCE MATERIALS
JOHN H. HART, PE
EARTH RETENTION REFERENCE DOCUMENTS & BIBLIOGRAPHY
1) PECK, HANSON & THORNBURN, "FOUNDATION ENGINEERING ", SECOND EDITION, 1973.
2) GROUND ANCHORS AND ANCHORED SYSTEMS, GEOTECHNICAL ENGINEERING CIRCULAR
NO. 4, F14WA OFFICE OF BRIDGE TECHNOLOGY, JUNE 1999.
3) JOSEPH E. BOWLES, "FOUNDATION ANALYSIS AND DESIGN ", FOURTH AND FIFTH EDITIONS,
1988 & 1996.
4) BRAJA M. DAS, "PRINCIPLES OF FOUNDATION ENGINEERING ", SECOND EDITION, 1990.
5) HOLTZ AND KOVACS, "AN INTRODUCTION TO GEOTECHNICAL ENGINEERING ", 1981.
6) ROBERT M. KOERNER, "DESIGNING WITH GEOSYNTHETICS ", THIRD EDITION, 1994.
7) NAVFAC 7.01, "SOIL MECHANICS ", SEPTEMBER, 1986
8) NAVFAC 7.02, "FOUNDATIONS AND EARTH STRUCTURES ", SEPTEMBER, 1986
9) HANNA, "FOUNDATIONS IN TENSION - GROUND ANCHORS ".
10) FHWA/RD- 82/047, "TIEBACKS ", JULY 1982.
11) PTI, "POST- TENSIONING MANUAL ", FIFTH EDITION, 1997.
12) PTI, "RECOMMENDATIONS FOR PRESTRESSED ROCK AND SOIL ANCHORS ", THIRD EDITION,
1996.
13) ASCE, "SERVICEABILITY OF EARTH RETAINING STRUCTURES ", GSP #42,1994.
14) FHWA, FHWA -RD -75 -128, "LATERAL SUPPORT SYSTEMS AND UNDERPINNING ", APRIL 1976,
VOLUMES I, II, III.
15) ASCE, GEOTECHNICAL SPECIAL PUBICATION NO. 74, "GUIDELINES OF ENGINEERING
PRACTICE FOR BRACED AND TIED -BACK EXCAVATIONS ".
16) ALAN MACNAB, "EARTH RETENTION SYSTEMS HANDBOOK ", 2002.
SOIL NAILING REFERENCE DOCUMENTS & BIBLIOGRAPHY
1) ASCE, "SOIL NAILING AND REINFORCED SOIL WALLS ", 1992.
2) FHWA/GOLDER PUBLICATION # FHWA- SA- 96- 069, "MANUAL FOR DESIGN AND
CONSTRUCTION MONITORING OF SOIL NAIL WALLS ", NOVEMBER 1996.
3) ASCE, "GROUND IMPROVEMENT / GROUND REINFORCEMENT / GROUND TREATMENT"
SPECIAL PUBLICATION #69, JULY 1997.
4) XANTHAKOS, ABRAMSON & BRUCE, "GROUND CONTROL AND IMPROVEMENT ", 1994.
5) FHWA -IF -03 -017 " GEOTECHNICAL ENGINEERING CIRCULAR NO.7 -SOIL NAIL WALLS ",
MARCH 2003
SOFTWARE
1) CALIFORNIA DOT, "SNAIL PROGRAM ", VERSION 2.11 -PC VERSION.
2) RISA TECHNOLOGIES, "RISA -21) VERSION 4.0, RAPID INTERACTIVE STRUCTURAL ANALYSIS -
2D, FRAME ANALYSIS.
3) GEO -SLOPE INTERNATIONAL, "SLOPE -W ", VERSION 5.17
OTHER REFERENCE DOCUMENTS & BIBLIOGRAPHY
1) AMERICAN INSTITUTE OF STEEL CONSTRUCTION, "MANUAL OF STEEL CONSTRUCTION -
ALLOWABLE STRESS DESIGN', NINTH EDITION, 1989
2) AMERICAN INSTITUTE OF STEEL CONSTRUCTION, "MANUAL OF STEEL CONSTRUCTION -
LOAD AND RESISTANCE FACTOR DESIGN', THIRD EDITION, 2001
3) ACI 381- 99/318R -99, "BUIDING CODE AND COMMENTARY ", 1999.
4) ANSI/ASCE 7 -95, "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES ".
5) ' ACI, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 -99) AND
COMMENTARY (ACI 318R -99).
6) ANSI/AF &PA NDS- 1997, "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION'.