HomeMy WebLinkAboutVK462 May 14, 2010 Sprinkler 54a MIRAGE° STANDARD AND N I I a:N:G:*: QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Mirage°Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to '/2' (12.7 mm) of vertical adjustment. The two-piece - design allows installation and testing of the sprinkler prior to installation of the cover plate. 50,11 The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has - been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2032 and 0786-CPD-40249 Refer to Approval Chart 1 and Design Criteria on page 54c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 54d for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Viking Technical Data may be found on Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to The Viking Corporation's Web site at 250 psi (17.2 bar)for high-pressure systems. High-pressure (HP) http://www.vikinggroupinc.com. sprinklers can be identified by locating "250" stamped on the deflec- The Web site may include a more recent tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar)wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to-65 °F (-55 °C) Patents Pending `cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-e, dated August 13, 2009. (Split the Approval Charts to separate cULus Listing requirements from FM Approval requirements.) Sprinkler 54b May 14, 2010 MIRAGE° STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage°Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E For example, sprinkler VK463 with a 155 °F/68 °C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome= F, Painted White=M-/SW1004, Painted Ivory= M-/SW1634, Painted Black= M-/SW1007 Temperature Suffix(°F/°C): 135°/57° LIL(139°/59° FM)=A, 165°/74°=C For example, cover 13504 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 13504FC. Note: Square cover plate 15394 cLlLus Listing is for the 135°F(57°C)temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches": A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or B. Head Cabinet Wrench Part No. 14031— (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) –Requires a''/i'ratchet(not available from Viking).—Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5)sprinklers (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. May 14, 2010 Sprinkler 54c MIRAGE° STANDARD AND a:N:G:*: QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Bulb Color Classification Temperature Rating' Ceiling Temperature Assembly(Required) Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C)cULus Red 139 °F (59 °C) FM Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. ��� C U S j0� Q� DO NOT PAINT 9� y � o n v VIKING �� Identification of Custom Paint Color All custom color painted, cover plates will have an identifying label affixed to the inside of the cover, that Indicates custom 3-5/16" (84,1 mm) color and will have a representative sample Ca paint dot) of the paint or the label Figure 1: Identification of Custom Paint Color for Concealed Covers Figure 2: Square Cover Assembly 15394 Sprinkler 54d May 14, 2010 MIRAGE° STANDARD AND i CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Sprinkler Temperature Rating Cover Plate Temperature Rating Mirage"Concealed Pendent Sprinklers VK462 and VK463 AW1*Cover Plate Finish KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Listings and Approvals° SIN Water Working (Refer also to Design Criteria below.) Part No. Inch mm U.S. metric2 Pressure cli NYC6 VdS LPCB Standard Response Applications 13503A VK462 1/2" 1 15 1 5.6 1 80.6 1 175 psi (12 bar) -- AY1,CZ1 — 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) — AV2, BW2 AV2, BW2' Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW1 — — AY2, CZ28 14697A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1 AV1, BW1 — — — 13667A VK463 1/2" 15 5.6 80.6 250 psi(17.2 bar)3 AV1, BX1 AV1, BW1 Cover Plate Assembly Temperature Ratings' Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings V- 135°F(57°C)cULus Listed cover 13504'or 13642' (large diameter) 1 - Polished Chrome, Brushed A- 155°F(68°C) W- 165°F(74°C)cover 13504' or 13642' (large diameter) Chrome, Bright Brass, Antique X- 165 °F (74 °C) cover 135041, 13642' (large diameter), or 15394' Brass, Brushed Brass, Brushed B-175°F(79°C)and 200°F(93°C) (square cover plate) Copper, Painted White, Painted C-200°F(93°C) Y- 135°F(57°C)cover 13504' Ivory,or Painted Black Z- 165°F(74°C)cover 13504' 2-Polished Chrome, Painted White Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Z Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in i divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the deflector. °This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for an additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 32. ' Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. S Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. 'The 135/139°F cover has an orange label.The 165°F cover has a white label. 1'Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA- UL (Also refer to Approval Chart 1 above.) cli Listing Requirements: Mirage®Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group ll. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13.Maximum spacing allowed is 15 ft.(4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m)unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 or Ii for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stand- ards, whenever applicable. May 14, 2010 Sprinkler 54e MIRAGE° STANDARD AND NJ I KJ:N:C:*j: QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) Sprinkler Temperature Rating Cover Plate Temperature Rating Mirage" Standard Response Concealed Pendent Sprinkler VK462 Awl 4-Cover Plate Finish KEY Sprinkler Base NPT Thread Size Nominal K-Factor Maximum FM Approvals3 Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric2 Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AW1,BX1 Cover Plate Assembly Temperature Ratings^ Cover Plate Assembly Finishes' Sprinkler Temperature Ratings W- 135 OF (57 °C)cULus Listed cover 135041, 13642' 1 - Polished Chrome, Brushed Chrome, Bright A- 155 OF(68°C) (large diameter), or 15394 (square cover plate) FM Brass, Antique Brass, Brushed Brass, Approved as 139 OF(59°C) B-175 OF(79°C)and 200 OF(93°C) X - 165 OF (74 °C) cover 135041, 13642' (large diam- Brushed Copper, Painted White, Painted eter),or 15394' (square cover plate) Ivory,or Painted Black Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. ^The 135/139 OF cover has an orange label.The 165 OF cover has a white label. ' Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances,and standards, whenever applicable. Sprinkler 54f May 14, 2010 MIRAGE° STANDARD AND NIKJNG* QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Sprinkler Wrench Sprinkler bK Flat 2-1/4' (57,2 mm) Frame diameter opening Arms is required in the ceiling. Sprinkler and Adapter Assembly (Protective Cap is removed for installation--use Wrench 14031 > Iff NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms, Wrench (Part No. D❑ NOT overtighten, 14047W/B)Kw Use only the designated _ is shown) sprinkler wrench, Viking Part Number 14047W/B or 14031. AwA 1/2' ratchet is required (not D❑ NOT apply more than available from Viking). 25 ft. lbs. of torquie. A leak tight seal should be achieved Step 2: Carefully press the by turning the sprinkler Step 1; Carefully slide the wrench upward and turn slightly clockwise 1 to 1-1/2 turns wrench sideways around to ensure engagement with the beyond finger tight. the deflector and pins. sprinkler wrench flats, Figure 3: Sprinkler Installation and Correct Use of Wrenches 1/2' (15 mm) NPT 2-9/16" 2-1/16' 2-3/16" (65 mm) (52 mm) (55 mm) Maximum Minimum 2-3/4' (70 mm) or 3-5/16" (84.1 mm) Note) Upon sprinkler activation, the deflector descends to approximately 13/16' (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F103005 Replaces page 54a-e, dated August 13, 2009. (Split the Approval Charts to separate cULus Listing requirements from FM Approval requirements.)