Loading...
HomeMy WebLinkAboutM10-0102NO TE: TH/ S PERMI T MUS T BE POS TED ON JOBSI TE A T : �ow�o�vnQ, ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f.970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 760 POTATO PATCH DR VAIL Location.....: Parcel No...: 210106302015 OWNER MYHREN, VICTORIA H. O6/18/2010 355 CLAYTON ST DENVER CO 80206-4228 APPLICANT HOME & HEARTH OUTFITfERS 730 S. JASON ST. #28 DENVER COLORADO 80223 License: 368-M CONTRACTOR HOME & HEARTH OUTFITTERS 730 S. JASON ST. #28 DENVER COLORADO 80223 License: 368-M 06/18/2010 Phone: (303) 327-4654 06/18/2010 Phone: (303) 327-4654 Desciption: ADDITION AND REMODEL: INSTALL GAS LOG SET IN EXISTING MASONRY FIREBOX (WOOD TO GAS CONVERSION) Valuation: $6,000.00 ALL TIMES Permit #: M10-0102 Project #: PRJ10-0007 Status . . . : ISSUED Applied . . : O6/18/2010 Issued . . : O6/24/2010 Expires . .: 12/21/2010 ..............................................+.........«..........».*.......,...FEE SUMMARY.......«.................«...........,'.........,�.......,.,..........�....,......,......... Mechanical Permit Fee--> $120.00 Will Call--------> $4.00 Total Calculated Fees---> $154.00 Plan Check--------------> $30.00 Use Tax Fee-----> $0.00 Additional Fees-------> ($154.00) Investigation-----> $0.00 TOTAL PERMIT FEE—> 50.00 Total Calculated Fees--> $154.00 Payments------------> 50.00 BALANCE DUE-------> 50.00 ................ «.,, t................+................................:.............. «.............». «......., �..........................+................................................. APPROVALS Item: 05100 BUILDING DEPARTMENT 06/23/2010 cg Action: AP Item: 05600 FIRE DEPARTMENT �...... �... w....::........:.,. �.»....,..........., R.., �.... w.......,...»:........»...........: ...............::... *......... «.......:...,........,...,.,.......... *......,...................... CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 ..... «....:.... «,+..:.»»......,. �,..........,' ..........................,..�........... ««..:.:................::.......»........::...:..,. �..,.........,'.,. �........... �..... �.+............... DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTI AM - 4 PM. / Signature of mechcan ical�ermit_041908 SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 O T OUR OFFICE FROM 8:0( � �� �2� � � � wn `or Contractor Date til�(c�(N.I�� . . . MECHANICAL PERMIT Boiler / Furnace & Fireplace Annlications MUST include: Complete Mechanical Room Floor Plan with Dimensions ❑ Boiler size & efficiency Combustion Air Duct Size and Location ❑ Equipment Cut Sheets for Fireplaces/Log Sets Flue detail or Vent size, location & termination Manufacturer's info showin make, model & a r� Gas Piping layout including devetopment length calculations Heat Loss Calculations Project Street Address: '7(0� �v72�o f4�c�i �-� 2� (Number) (Street) (Suite #) BuildinglComplex Name: S�n��L�"" F� r-� rc.y Contractor Infonnation: N�o�E +� H�'��'� o�' Company: � Company Address: Pa 8dx � 9G Ciry: �D`✓�4QDS State: �� Zip: �i�32 Contact Name: �y�� f%ar /Q,� d Contact Phone: 976 - �Q'S- 86�2 E-Mail fc�r/c �%�in�d�ol�%ie��occ'�%itc:s.GOn� Town of Vail Contractor Registration No.: J��� I'" 1 X ' G//�1�0 Contractor Signature (required) Property Information Parcel #: _ � � �+=��(� J V � � — �J�s (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: /�����e.r� (Commercial Properties) Owner Name: �yl,r« Complete Valuation for Mechanical Permit: (including fireplaces) ,«' Mechanical $: �o� DOd �a ��;�- C�-�a� ��P C: \cdevlfortns\pettnits\building�nechanical�ermit_O 10110 Office Use: Project #: I� 1� �'' � Q v� Building Permit #: �j�. � '��� l � Mechanical Permit #: �i { 0- o I a 2 Lot #: � Block #2 Subdivision: �at � � I�lJ-l�'� � Define Scope and Location of Work: il D � o n��" �i � G A r GaG F,�e.E"pc�,•vGE" ra A ni E���S7i�vG �IVI.�,g PiYI �'�/ -�i f �IoG1iG -�T (use additional sheet if necessary) ❑ Gas Piping Included aY Gas Piping by Others � Wood to Gas Fireplace Conversion Boiler Location: Interior ( ) Exterior ( ) Other ( ) Number of Existing Fireplaces: Gas Appliances Gas Logs � Wood/Peliet Number of Proposed Fireplaces: Gas Appliances Gas Logs / Wood/Pellet Type of Building: Single-Family ( ) Dupiex ( ) Multi-Family ( ) Commercial ( ) Restaurant ( ) Other ( ) Date Received: � ���a�� JUN 17 2010 TOWN OF VAlL 0 0 ° 6AS LO�S SYS1�M �� . �* ,�, ,:� � � . . =1 � INSTALLATION & OPERATIHG INSTRUCTIOHS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you can not reach your gas supplier, call the fire department. — Instafiation and service must be performed by a qualified installer, service agency or the gas supplier. INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR LOSS OF LIFE. REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION FOR PROPER INSTALLATiON. FOR YOUR SAFETY CAUTION DO NOT STORE OR USE THIS APPLIANCE MUST BE GASOLINE OR OTHER INSTALLED ONLY IN A SOLID-FUEL FLAMMABLE VAPORS AND BURNING FIREPLACE WITH A LIQUIDS IN THE VICINITY OF THIS WORKING FLUE AND CONSTRUCTED OR ANY OTHER APPLIANCE. OF NON-COMBUSTIBLE MATERIAL. DO NOT INSTALL IN A MANUFACTURERED HOME OR MOBILE HOME. TABLE OF CONTENTS TABLE OF CONTENTS ............................................................ 2 1MPORTANT INFORMATION ................................................... 3 GENERAL INFORMA T10N ....................................................... 5 GENERAL INSTALLAT/ON ...................................................... 6 BURNER /NSTALLAT/ON /NSTRUCTIONS ............................ 7 LOGS /NSTALLATION /NSTRUCTIONS ................................. 9 EXAMPLE OF PROPER POSITION/NG OF LOGS & TW/GS10 LlGHT1NG /NSTRUCTIONS ................................................... 11 SAFETY PILOT VALVE .......................................................... 12 MA/NTENANCE ...................................................................... 13 TROUBLE SHOOTING GUIDE ............................................... 13 SAFETY TESTED AND APPROVED ..................................... 14 CUSTOMER SERV/CE ........................................................... 14 LIFETIME WARRANTY .......................................................... 14 THANK YOU! .......................................................................... 14 WARRANTY CARD ................................................................ 15 � ��� Page 2 of 15 EIKLOR FLAMESO Tech Support Hotline: 888.295.5647 IMPORTANT INFORMATION READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING AND USING THE EIKLOR FLAMES�CAS LOGS SYSTEM The EIKLOR FLAMES� Gas Logs System must be installed in a"Class A" fully vented solid-fuel burning firepiace constructed of non-combustible materials. Fireplace MUST adhere to non-combustible hearth extending a minimum 20", non-combustible lintel area extending minimum 14", noncombustible materials extending 8" on both sides of fireplace opening. 1. Check the appliance for proper gas type. The type of gas will be marked on the rating plate. 2. The installation and the provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the CSA B 149.1, National Gas and Propane Installation Code. 3. Solid fuels shall not be burned in a fireplace where a decorative appliance is installed. 4. The minimum permanent free opening of the fireplace chimney damper flue should not be less than 1/10th the area of the fireplace opening. 5. The chimney opening must be in a fixed manner to maintain permanent vent opening, see chart below. To accomplish this, remove damper (if required), install damper stop on the edge of the damper plate to prevent this accidental closing. NOTE: Damper must be fully open. MINIMUM CHIMNEY HEIGHT AND FLUE OPENINGS: MODEL CHIMNEY HEIGHT MIN.FLUE OPENING MOMBO� In accordance to local In accordance to local codes codes 6. MINIMUM FIREPLACE OPENING MUST ADHERE TO THE SIZE CHART(S) BELOW: MOMBO� FIREPLACE FIREPLACE FIREPLACE BTU BTU LIQUID MODEL HEIGHT WIDTH DEPTH N GAS�L PROPANE 38" ' 30" 48" 18" 115,000 115,000 42" 30" 52" 18" 175,000 175,000 48" 30" 58" 18" 200,000 200,000 52" 30" 62" 18" 220,000 220,000 58" 30" 68" 18" 300, 000 300, 000 64" 30" 74" 18" 325,000 325,000 70" 30" 80" 18" 400,000 400,000 75" 30" 85" 18" 400,000 400,000 , r���� Page 3 of 15 EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 7. A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction of combustion air. 8. Gas supply pressures: Minimum inlet supply pressure for the purpose of input adjustment: Maximum inlet gas supply pressure: Manifold pressure: NATURAL 5.0" w.c. 10.5" w.c. 3.5" w.c. PROPANE 10.5" w. c. 13.0" w.c. 10.0" w.c. 9. The appliance and its appliance main gate valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of'/2 psi (3.5kPa). The appliance must be isolated from the gas piping system by closing its equipment shutoff vatve during any pressure testing of the gas supply piping system at test pressure equal to less than'/z psi (3.5kPa). 10. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 11. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 12. The fireplace and venting system (chimney and flue) needs to be inspected and cleaned once a year by a qualified service technician. CARBON MONOXIDE POISONING MAY LEAD TO DEATH WARNING: WHEN USED WITHOUT FRESH AIR, UNIT MAY GIVE OFF CARBON MONOXIDE, AN ODORLESS, POISONOUS GAS. YOU MUST MAKE ADEQUATE PROVISIONS FOR ACCESSIBILITY AND FOR COMBUSTION AND VENTILATION AIR SUPPLY. Page 4 of 15 � - ,, �,���', ►. r' _ � EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 GENERAL INFORMATION TOOLS RECOMMENDED FOR INSTALLATION Adjustable wrench Open-end wrench (7/16") Pipe wrench (10.0°) Flashlight Open-end wrench (3/4") Slip joint pliers (7.0") Flat blade screwdriver 50/50 soap/water solution Pipe thread sealer, non-hardening % ,�!�:.� ., + t�ncK •tt us[o - ` vuovw+E ev� ��� w�t at" StA�NLL55 ;1LLt� ��� . ��.;� ,`. rr 1'al' STFFI �O:TS 1! t l �U`.,fy (i•.YlilL7� [IYF'I(:A;j , �•..'l� . 1 �/. VILUI � ARa�'r;FT � U a�' . � . 3?1'ti.TAINtP55 STFPI � �. ti il: `�., ��� i,���� �� ,1� � �� ��� , � _ ti�� :�� : 1 fNDT SM�WN) A�SFMR.'r DRAW P,'r rxrr ro sr.0 r 31 i Ifil!il% I IkhAf S� � '�fONEOCk) c.nc i n�; ���cT=a� � ��. ' ' tari-���.� ..,�°., .,�� Page 5 of 15 EIKLOR FLAMESO Tech Support Hotline: 888.295.5647 GENERAL /NSTALLAT/ON Remove all ashes and debris from the fireplace. Be sure gas supply to the fireplace is in the "OFF" position. Remove gas log lighter for solid fuel burning fireplace if applicable. Position the damper stop over the edge of the damper blade and tighten bolt. This should hold the damper partially OPEN' in case of an accidental closure. (See Figure 1) Page 6 of 15 �Ai.�F'tR —.� , �r�s 5,,� ��1�, � DAMF'ER STOP , �L- i - - -' _ , -.�r._ _ Figure 1 � � �= I I,' �� �_ , � � � r�✓�;',�-'� o ,1 -;; � l �:���_...°J�U l EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 BURNER INSTALLATION INSTRUCTIONS THE EIKLOR� GAS LOGS SYSTEM MUST BE INSTALLED BY A LICENSED PLUMBER, LICENSED GAS FITTER, OR IN �� SOME LOCALITIES A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. If the gas control valve is instailed on the left side of the burner and the gas supply line comes into the right side of the fireplace, the gas supply line must continue to the left side of the fireplace (as close to the rear firebox wall as possible) and terminate behind the gas valve inlet using rigid '/2" black iron pipe. At this point, only the �/" aluminum manifold cab be used to complete the connection to the gas control valve. It may be necessary to cut and re-flare the aluminum manifotd to the desired length for proper positioning of the burner pan. 1. Remove all ashes and debris from fireplace. 2. Be sure gas control valve to fireplace is in the OFF position. 3. Remove gas log tighter for solid-fuel burning fireplace if applicable. 4. To prevent accidental closing of the fireplace chimney damper, the damper must be: a. Welded FULLY OPEN or b. Completely removed or c. FULLY OPEN using enclosed damper stop installed on the edge of the damper plate. 5. Place your EIKLOR FLAMES� burner in fireplace with grate spokes toward the front of fireplace and vertical baffle should be in line with chimney. (See Diagram 1) Page 7 of 15 ' (;IIIMNI 1'" li � -'- E?/�lilf IN-LINE WITH CHIMNE'r ----fil P�f� LiIJf?N�I.' %�/ . ,-` __ ` � � %/�i /�/ ;'�� ,/i�, i Diagram 1 F� F A � �� ��,. ,� Q � �� EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 6. For a natural or liquid propane EIKLOR FLAMES� Gas Logs System equipped with a safety pilot valve system. (See Diagram 2) � ' " ��` ` '� � �.�•, �;ACE: I LL � U>ED FOR j PROPANF RUP,NFR \ � uiagram 2 1�F� n 4--�f ��n a. Apply pipe thread sealer to gas supply line coming into fireplace (See Diagram 2, point A) and instalt �/" x%z" brass supply fitting (See Diagram 2, point 8) and tighten. b. Install longer end of flared aluminum manifold with s/" brass flair nut (See Diagram 2, point C) to'/" x%z " brass supply fitting coming into fireplace, and shorter end (See Diagram 2, point D) to back of gas control valve and tighten. When connections are complete, NEVER TEST FOR GAS LEAKS WITH A LIT MATCH OR OPEN FLAME. Slowly turn gas control valve to ON position and use 50/50 soap and water solution to test for leaks. Apply 50/50 soap and water solution with a toothbrush or small paintbrush over all gas connections. A teak will be evident by observation of bubbles on gas connections. If bubbles are observed, retighten leaking gas connectors. Page 8 of 15 � � �,C7. � �,, : _,d � � EIKLOR FLAMESO Tech Support Hotline: 888.295.5647 LOGS INSTALLATION /NSTRUCTIONS 1. Place back log on burner and place front log on front support. Front and back log are interchangeable; we recommend using the longest log in front. (See Diagram 3) 2. Puli front log toward back log to create 1 1/2" space between front log and spokes of grate. (See Diagram 3) Diagram 3 3. Place twigs in grooves on top of front and Diagram 4 back log. (See Diagram 4) 4. Using ember material, create thin embers (small like a penny and thin like a potato chip) to lightly cover burner pan. Too thick or too many embers will reduce the desired glowing effect. Place lava rock up to and around sides of ember bed to simulate ashes. 5. Completed view. (See Diagram 4) � r.. � WARNING: Failure to position items in accordance with these diagrams or faifure to use only parts specifically approved with the EIKLOR FLAMES� Gas Logs System may result in property damage, personal injury or death. 1 �,—__l�___—_, ��I�:.Q..�1��°J�'_'1 ,,, Page 9 of 15 EIKLOR FLAMESU Tech Support Hotline: 888.295.5647 � � 'NG OF LOGS & TW/GS � MOMBO� Front Log & Back Log Positioning �,,. � # � r . ,. . _ , _ � , ,, ��. t, MOMBOO Large & Small Twigs Positioning ,-V'-�--.-,,�`.--.' ; �� ' � �, �� Li Page 10 of 15 EIKLOR FLAMES� Tech Su Pv�J��v.V J�� � pport Hotline: 888.295.5647 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactiy, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be fighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplie�'s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push or turn the gas control knob. Never use tools if the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water, immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. t,� - ,�,, � � L- _� Page 11 of 15 EIKLOR FLAMESO Tech Support Hotline: 888.295.5647 SAFETY P/LOT VALVE 1. To prevent accidental closing of the fireplace chimney damper, fireplace chimney damper must be: a. Welded FULLY OPEN or b. Completely removed or c. FULLY OPEN using enclosed damper stop installed on edge of damper plate. 2. For natural or liquid propane Eiklor Flames� Logs System with a safety pilot valve: NATURAL GAS or LIQUID PROPANE a. Read safety information label located on top of gas control valve. b. Find pilot mounted on left side of burner. c. PUSH IN gas control knob and turn it counterclockwise ❑ to PILOT, keep gas control knob PUSHED IN and immediately light pilot with a match. d. After pilot is lit, continue holding gas control knob in the PUSHED IN position for approximately one (1) minute to bleed air from the gas supply line and to prove the pilot. e. Release gas control knob and pilot should remain lit. If gas control knob does not pop up when released, STOP and immediately call a qualified service technician or gas supplier. If pilot will not remain lit after several tries, turn the gas control knob clockwise :1 to the OFF position and call a qualified service technician or gas supplier. f. After pilot is lit, turn gas valve control knob counterclockwise ❑ to the ON position. 3. Keep glass doors OPEN during operation and have fireplace screen CLOSED during operation. 4. To turn the MOMBO� Gas Logs System OFF: a. Turn the gas control valve clockwise � to the OFF position, pilot and main burner wilf extinguish. Page 12 of 15 �� ����; �.��� �.�,' ' • �• • � 9 ON � OFF (""'":`;��')� ..» � ..�. ..o, .�» �, �-„_�_ � �_��, .e • .• • -w;t�.�. 1' � ot��r.+s . # ; �purq�.a++. wa� . � �eMa i'�an� dd0 � NO � _ ,k. .a • �• • �.�VLI ����M�I �°J D) :� EIKLOR FLAMESO Tech Support Hotline: 888.295.5647 MA/NTENANCE Your EIKLOR FLAMES� Gas Logs System will last a lifetime, but periodic maintenance (at least once a year) is recommended. EIKLOR FLAMES� authorized dealers are always available to help. They will ctean and adjust your burner and gas control valve and make sure that everything is working properly. They will clean your logs; heavy soot build up on your logs should be removed, but a light soot build up is desired for a realistic appearance. Soot can be removed with a small paintbrush or vacuum cleaner; do not vacuum the SUNGRO horticulture vermiculite, embers or lava rock. Can you clean it yourself? Yes you can if you have the proper training! Safety is of prime concern so we recommended that you call your EIKLOR FLAMES� authorized dealer for proper maintenance. If an EIKLOR FLAMES� authorized dealer is unavailable, call us directly at 888-295-5647 and we will promptly answer your call. TROUBLE SHOOTING GUIDE PROBLEM REASON SOLUTION Pilot will not light Air in gas supply line Bleed gas supply line Pilot hood blocked Check for debris or dirt Clean pilot Low gas pressure Make sure manual gas control valve is in the ON position Check gas line for size and blockage Dirty pilot Pilot should be blue and hitting the thermocouple properly Clean ilot Pilot will not stay lit Pilot hood not aimed at Pilot hood bent; replace pilot or angle pilot hood properly so thermocouple pilot flame hits thermocouple'/" below tip of thermocouple Pilot line bent Replace pilot line Thermocouple is loose Tighten thermocouple nut at gas control valve Thermocouple cracked Replace thermocouple Thermocouple worn out Replace thermocouple Excessive down draft Install chimney cap Outside Chimney too close to other peaks Check chimney flue for proper height Poorl desi ned chimne Gas logs bumer goes �ow gas pressure; pilot Make sure manual gas control valve is in the ON position out fades Dirty pilot Gas line sized improperly Thermocouple is loose Tighten thermocouple nut at gas control valve Thermocou le worn out Re (ace thermocou le � ,..y. � �� luJ Page 13 of 15 EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 SAFETY TESTED AND APPROVED Your EIKLOR FLAMES� Gas Logs System is safety tested and approved by CSA Intemational to ANSI Z21.60 b— 2004. �fSlyq � nt��� CEtiIFlED � CUSTOMER SERVICE EIKLOR FLAMES� is committed to customer service and exceeding customer expectations. We are available Monday — Friday 8:30 AM — 5:00 PM EST toll-free @ 888-295-5647 to provide technical assistance and to answer any questions you may have regarding our products. LIFETIME WARRANTY Our 20+ years of success is the result of exceeding customer expectations and as we look ahead, this principle remains at the core of our culture. Our continued strong performance is achieved by our manufacturing excellence. You have a LIFETIME WARRANTY with our products, our continuing commitment to our customers. If you should accidentally break a log, or any issue you may have with your EIKLOR FLAMES� Gas Logs System, please call your EIKLOR FLAMES� authorized dealer, and if your dealer is unavailable, call us at 888-295-5647 and we will promptly answer your call. It is important for you to register your EIKLOR FLAMES� Gas Logs System with us, so please complete the warranty card on Page 17 of this owner's manual and send it back to us via mail or facsimile. 1. Your MOMBO� bumer system has a lifetime warranty. Your MOMBO� gas logs have a 1 year warranty if burned as recommended in intervals of 4 hours on an 1 hour off. 2. If your MOMBO� Gas Logs System was purchased with a gas control valve factory mounted at EIKLOR FLAMES� the gas control valve has a one-year warranty against any performance defects. If your MOMBO� Gas Logs System was purchased with a gas control valve not factory mounted at EIKLOR FLAMES� the gas control has no warranty. 3. All painted surfaces that get wet due to rain, flooding, household pets, wild animals or birds; or that get damaged due to negligence or disaster have no warranty. 4. Embers and lava rock that get wet due to rain, flooding, household pets, wild animals or birds; or get damaged due to negligence or disaster, have no warranty. THANK YOU! Please accept our thanks for choosing the EIKLOR FLAMES� Gas Logs System for your fireplace. We will continue to do everything possible to merit your confidence you have in our products. : r :��vi a °J�� Page 14 of 15 EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 �� SENTINEL ELECTR�NIC FI REPLACE DAMPER WARNING: Installation and service must be perFormed by a qualified installer, service agency or the gas supplier. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Read these instructions carefully and completely before proceeding with the installation. Warning: Do not install this damper on a chimney burning solid fuel such as wood. Warning: Do not install this damper on a chimney used for venting central heating or water heating appliances. sg� �S � oioo-o� F��E SEMTINEL 1.0 DESCRIPTION The Flue Sentinel Electronic Fireplace Damper is designed to increase the comfort and energy efficiency of residential homes with gas-fired fireplaces. Consisting of a stainiess steel pipe/blade assembly and solid-state controller housed in a weather- proof enclosure, the damper is instailed outdoors on the top of the chimney of a gas-fired flreplace. The damper automatically opens the flue outlet when the fireplace is turned on and automatically closes off the flue outlet when the fireplace is turned off. By closing off the flue outlet the fireplace is not in use, the damper prevents drafts and conserves energy by preventing heat in the home from escaping through an open flue. ��� `�� . �. = �'�. i :.....�,� : �, \ , – ` ._ . ...�.. - .—_L_.__.._ „� � ; .a i f���E � �� StM11MiL i �e ^�.��.....��aa ' �:�.. � � � _� � '�; FLUE SENTINEL The Flue Sentinel is design certified by the Canadian Standards Association (CSA) to CSA Requirement No. 2.03-US for Automatic Vent Damper Devices for Use Outdoors on Fireplace Chimneys and is covered by U.S. Patent No. 6,915,799. 1.2 SPECIFICATIONS Table 1. Operating Specifications Voltage (range) Frequency Current (running) Maximum current rating for output circuit 24 VAC (Max. 27.6, Min. 20.4 VAC) 50/60 Hz 80 mA 5A ------ -- Operating temperature range Controller: (-40) - 140°F Timing E Pipe: (-40) - 650°F - __ __ 7 seconds to open 30-40 seconds to close (w/ Status Module) 0100-01 � .' _. .....__.._ .............___.___. _ �;�__, p C I I``� _ A _ -� 1 tl'fllllilllllilfilllll(III�IIII� �illlllillllill(Illlllllliillllill'1 - �----- --� � � 1 i i ----f I� � � � � � , ��� ; , �, � i L _ _ _, r,-: � � ' ' -' - f � ��� �-j i , � i ,- .. _ j, _ ,, � - -- - - � � ------ ' 1 ,-- - __ Table 2. Flue Sentinel Dimensions and Weight- FSE-8 thru FSE-16 PART NO. DIM. A DIM. B DIM. C DIM. D Wf. (Ib) FSE-8 7.8 10.5 17.0 13.8 7.g FSE-10 9.8 10.5 19.0 15.8 g.g FSE-11 10.8 10.5 20.0 16.8 9.4 FSE-12 11.8 10.5 21.0 17.8 10.0 FSE-13 12.8 12.5 22.0 18.8 11.3 FSE-14 13.8 12.5 23.0 19.8 12.0 FSE-16 15.8 12.5 25.0 21.8 13.3 'All dimensions are in inches. 3 ______.._ _ - ________.�� F��E SENTINEL 0100-01 ❑ F��E SENTINEI ''_ � � C -�. -- � m����cm��umnmumormm�mmr�mm� �- ------ ; B ; i �� � ��- _�J _1_�� _ - 0�1 � —A I � �umn�mrn�mmmiii�« --; _ --- --- ----- � --r — j ; �ai�, � _ ---�- ,�_-___. �_ Table 3. Flue Sentinel Dimensions and Weight- FSE-18 thru FSE-24 PART NO. DIM. A DIM. B DIM. C DIM. D WT. (�b) FSE-18 17.8 13.5 27.0 23.8 15.5 FSE-20 19.8 14.5 29.0 25.8 17.8 FSE-22 21.8 15.5 31.0 27.8 20.1 FSE-24 23.8 16.5 33.0 29.8 22.g 'All dimensions are in inches. Flue Sentinel Status Module Dimensions �---- --� i ; � , 60 ; � , � , � ' _ .� 1.5 Q10.2 (2)-- � . :� , `"r--�l s's � � i � - � � � fl�E ; � � n,�,�E � , o�-------o; L�� — � _. ,-- , ------- , ---4.0� "All dimensions are in inches. � 0100-01 , � , ' _ ___ 1iIIIIIiIlII11111T1(Illllrllllllll@ ,, Ir- 7} -- -� B I ► � , .--- � � _ ___ A _ _ � 10 � ���� Table 2. Flue Sentinel Dimensions and Weight- FSE-8 thru FSE-16 PART NO. DIM. A DIM. B DIM. C DIM. D WT. (Ib) FSE-8 7.8 10.5 17.0 13.8 7.g FSE-10 9.8 10.5 19.0 15.8 8.g FSE-11 10.8 10.5 20.0 16.8 9.4 FSE-12 11.8 10.5 21.0 17.8 10.0 FSE-13 12.8 12.5 22.0 18.8 11.3 FSE-14 13.8 12.5 23.0 19.8 12.0 FSE-16 15.8 12.5 25.0 21.8 13.3 "All dimensions are in inches. 3 �. : � fl�E SENTINEI o�oo-o� 2.0 INSTALLATION Warning: Do not install this damper on a Warning: Do not install this damper on a chimney burning solid fuel such as wood. chimney used for venting centrai heating or water heating appliances. The Fiue Sentinel has been designed to fit a variety of chimney types including masonry and manufactured chimneys. It features a mounting collar that seals the chimney, adjustable legs for means of attachment and a crimped outlet for mounting the chimney top. Figure1 is an example of a typical installation Installation of the Flue Sentinel must comply with the following requirements: The Flue Sentinel must be installed only on a factory built chimney or vent complying with a recognized standard, or a masonry or concrete chimney acceptable to the authority having jurisdiction. • The Flue Sentinel must be located on a chimney so that it serves only the single fireplace appliance for which it is installed. • The Flue Sentinel shall be installed in accordance with local codes, or in the absence of local codes, in accordance with the National Fuel Gas Code, ANSI Z223.1. • If the Flue Sentinel is to be installed on an air-cooled chimney, it must be installed with the appropriate Flue Sentinel Mounting Kit per the kit instructions. Installation steps: Set the damper in the opening of the chimney flue to check the fit. The damper's mounting collar should rest evenly on the top edge of the flue. Also check the orientation of the damper control housing and mounting legs to ensure the proper attachment and routing of the wiring harness. 2. Remove the damper and apply a bead of high temperature sealant on the top edge of the flue. 3. Center the damper in the opening of the chimney flue. 4. Adjust the mounting legs to rest on top of the chimney a�d secure with screws. Tighten the mounting leg bolts at the collar brackets. 5. Install the chimney top and secure per the manufacturer's instructions. 6. Install Status Module indoors in an area where the ambient temperature will not exceed 140 degrees F. Do not install in fireplace. Wire per Section 2.1 of these instructions. If you have any questions regarding the proper installation of the Flue Sentinel, contact Technical Service at 248-370-0149 (8:30am-5:OOpm EST). F��E SEMTINEI o� oo-o� F��E SEXTINEI .� _ _ __----_.___ _ _----_____ ___��--,__._..� I --�� . I�� �)�� i I' (�:`��- Chimney Top ,� � _- -_.- � Damper Harness _ -- Flue Sentinel �-~ ( Water- roof i'- ' - Mounting Leg .. . -- L! __ i- - -- Junction Box '� , � (� --- I Facade 4-Wire Cable __ , � ! ,-�" i � �-- 2" x 4" Framing -__ � i - - - '� ' �-. `���_ j ; 1/2" Drywall or Sheetrock I� � (See Local Code) � ; � I Notes ;I ' i �_ _ �� � � — _ � I �� �i !� �'- *Typically 18/4. Run in conduit if required or if installed on exterior of masonry chimney. "`�The Flue Sentinel is electrically interlocked with the main burner valvelcontrols of the gas log set. See Basic Wiring Diagram on pg. 8. On/Off Switch Ignition Module not shown. � �--- � -- - �--- 120/24V i Transformer � � � �, r----- ;r �'"� i' i � �; _ _:_:-� � ! : i � '_. -- - -.-� , , � - __ ,_- � ___ � --- ___ --- - *"`Gas Valve Status Module Gas Line Figure 1 6 ! ' - Manufactured Chimney � I. - Chase r" . Minimum Clearance to ' Combustibles Per Chimney '� ; Manufacturer Gas Log Set � � i ; 0100-01 2.1 WIRING F��E SEN71NEl Warning: This damper device must be Warning: Do not negate the action of any interlocked with all automatic gas valves existing safety or operational control. on the fireplace appliance. The following requirements must be met to ensure safe and proper operation: • The Flue Sentinel Electronic Fireplace Damper must be electrically connected to the fireplace appliance using the chimney upon which the damper is installed. • The damper must be installed in accordance with the NEC NFPA 70 (most recent edition) and/or local codes. • The damper must be installed using the wiring harness supplied with it. This harness has a mated connector which plugs into the damper controller. • The damper's wiring harness must terminate in a water-proof junction box mounted at the top of the chimney. • The wiring connecting this junction box to the appliance controis must be a minimum of 18 AWG and must be run in conduit if installed on the exterior of the chimney or required by code. Note: It is recommended that stranded wire be used with the Flue Sentinel Status Module to ensure good connections. • Figure 2.2 is a wiring connection diagram for a typical installation with an intermittent ignition system and optional Flue Sentinel Combustion Air Unit. • The damper control wiring must always be connected as follows: Brown - 24 VAC Hot Orange - Signal In Yellow - Signal Out Black - 24 VAC Common If you have any questions regarding the proper wiring of the Flue Sentinel, contact Technical Service at 248-370-0149 (8:30am-5:OOpm EST). 7 0100-01 � FL�E SENiINEL � .. . . _... ... . ._... . . .. _._ . , IGNITION CONTROL MODULE � 24V ' GND TH-W I - _ I- -- _ ' _�_�— �� i 1- , ; � � ' SPARK ELECTRODE/ _ ___ � �' � SENSOR GAS VALVE ( _ - --- _ ' i __ __ __ _--- ; � , �--; � � __ _ --. ____ __. ----� � TRANSFORMER �1 - 120 VAC 24 VAC L2 __ _ _ . � • FLUE s�,,cx � SENTINEL • • . .. ELECTRONIC eROGVra � �ORANGE . � � FIREPLACE _ rE��o�v _ _ _ _- DAMPER � , � FLUE Bu+c" ; � _ -- • SENTINEL BROWN COMBUSTION! � ORANGE AIR UNIT .__—_ . � _ __--- — __— RED (OPTIONAL) _ -- . _• - _ .._ -- __ FIREPLACE SWITCH • - _ Jr-- �r9 ' � i � -�-HOL�OPEN/AU�O—_1 � I, 24VAC HOT I '�. 24VAC COMMON . �� naeauce swrrcN oNro� , FLUE SENTINEL POWER I SIGNALTODAMPER --'- � �. ' GAS VALVElSIGNAL OUT-� �� � COMBUSTiONAIRUNIT�� � �� ; (OPTIONAL) � ; ��.. \� � �L � i SENTINEL STATUS MODULE ', J�� L. . ... . --.. _. - �:, _ � Figure 2 � 0100-01 3.0 Sequence of Operation When the fireplace is turned on, a 24V signal is sent by the fireplace control to the damper controller. The damper controller motor then rotates the damper blade, which is indexed to a cam, to the open position to allow products of combustion to pass through the flue outlet. The cam proves the damper is in the open position and switches 24V from the motor to the main gas valve or ignition system, which fires the main burner. When the fireplace is turned off, the fireplace control removes the 24V signal to the damper controller, shutting off the main burner. After a 30-40 second delay (when installed with a Flue Sentinel Status Module), the damper control►er motor then rotates the damper blade to the closed position and resets itself for the next time the fireplace is turned on. 0 4.0 Final Inspection Caution: Do not tum damper by hand. I Manually rotating the Flue Sentinel damper will damage the motor and void the j warranty. � � � Turn on the gas and electrical supplies to the appliance. Check the operation of the Flue Sentinel by cycling the appliance at least three times as follows: 1. Switch the fireplace control to turn on the fireplace. 2. The damper will open and fire the main burner. The damper must be in the open position when appliance main burner is operating. 3. Switch the fireplace control to turn off the fireplace. The main burner will immediately shut off and, after approximately 30-40 seconds, the damper will rotate to the closed position. If the Flue Sentinel Electronic Fireplace Damper and/or fireplace appliance does not operate as described above, check the Flue Sentinel Status Module and consult the Troubleshooting Chart on Page 11 for the proper course of action to resolve the problem. F��E SENTINEt 0100-01 �F�(IE SEMnNEt 5.0 Status Module The Flue Sentinel Status Module has been designed to aid in the servicing of a Flue Sentinel Electronic Fireplace Damper installation. It has the following features: • Four LEDs to aid in troubleshooting. • A service switch to allow the damper to be hefd in the open position while the technician services the gas controls of the fireplace appliance. • Built-in time delay that holds the damper open 30-40 seconds after the fireplace is shut off to allow the products of combustion to leave the flue. The following is a description of the function of each LED and a numeric code used in the Troubleshooting Chart on page 11: • Flue Sentinel Power (LED 1) - Indicates 24 VAC to Damper. • Signal To Damper (LED 2) - Indicates signal to open Damper. • Gas Valve/Signal Out (LED 3) - Indicates Damper has proved open and is sending signal to fireplace gas controls to turn fireplace On. • Combustion Air Unit (CAU} (Optional) (LED 4) - Indicates Combustion Air Unit has proven open. During normal operation the LEDs should be illuminated as follows: 10 � ;� � NOIDOPEN/AUTO i���� v� � , � I i%� 24YACHOT � j� 2iVA[[OMMON '._� �. '(�.5�, FlpEFUCE S1MrCH IXJ/OFF I ' � FIVESENTINELPOWFR �/ . 'il;� SIGNRI'O DAMPEA --'-- �� � j '.. � `J' GASVALVE/SIGNALOUi"'_� I � ����:� [OM&1STfONA1RVNR� _ �� i i IOPTIONAL) \� I ; ~ � �L � SENTINEL �I STATUS MODULE , ,.`- - ------ >;�, --- - �;� -- __ ---- -- -- ____ - Fireplace Switch Off LED 1 - ON LED 2 - OFF LED 3 - OFF LED 4 - OFF Fireplace Switch On LED 1 - ON LED 2 - ON LED 3 - OFF LED 4 - OFF --LED 1 ' LED 2 —r--LED 3 --�---LED 4 Fireqlace Switch On - Damper Open LED 1 - ON LED 2 - ON LED 3 - ON LED 4- ON (Only if CAU is installed) 0100-01 � Troubleshooting Chart Damper won't open Damper opens but appliance main burner(s) does not fire. Damper rotates continuously. Damper won't close, main burner off. .__.- . __ __ __ - _. ___-. _. '._ _' _ .._ . _. _ _- ___ Status Module/Possible Causes Action LED 1 OFF - No power or Check wiring and transformer. Repair insufficient power to Status or replace as necessary. Module. LED 1 ON, LED 2 OFF - No signal ; Check wiring and fireplace on/off to Status Module. switch. Repair or replace as , ; necessary. LEDs1&ZON- ' ' No signal into damper. � Check wiring. Repair or replace as � necessary. Obstruction preventing damper I Check for protruding screws or blade from rotating. binding in pipe/blade assembly and ' '� correct. Defective damper controller. Replace controller. LED 3 ON - Defective gas valve or , Check for power at valve andlor ignition control on appliance. control and, if present, replace � defective part. If not present, � check wiring and repair or replace � as necessary. LED 3 OFF - No signal from damper. ', Check wiring. Repair or replace as ', f necessary. i Defective damper controller. i Replace controller. Defective damper controller. � Replace controller. ---- i � - -- _ _---- ---- -- _ _ - i LED 1 OFF - No power or insufficient power , Check wiring and transformer. Repair to Status Module. or replace as necessary. LED 1 ON - Service switch on Status Module in Hold Open position No power or insufficient power to damper. 11 ' Move switch to Auto position. ; Check for power out of Status Module !, after 60 seconds. If present, check wiring and repair or replace as , necessary. If not present, replace Status Module. 0100-01 F��E SENiINEt Damper won't close, Obstruction preventing damper main burner off. � blade from rotating. (cont.) Defective damper controiler 6.0 Maintenance Caution: Label all wires prior to disconnection when servicing controls. Wring errors can cause improper and dangerous operation. The Flue Sentinel has been designed to provide years of maintenance ftee service. However, for continued safeoperation, the Flue Sentinel, chimney and fireplace appliance should be examined once a year by a qualified service agency. It is also recommended that the homeowner examine these components at least every (6) months, with particular attention given to deterioration from corrosion or other source. Check for protruding screws or binding in pipe/blade assembly and correct. Replace controller. Flue Sentinel, Inc. 143 Northpointe Dr. Orion, MI 48359 USA Voice:248-370-0149 Fax:248-364-4588 www.fluesentinel.com 12 0100-01 WARRANTY CARD [WE NEED YOUR INFORMATIONI Your information Name: City, State: Phone number. MOMBO� Gas Logs System size: Control valve type: Control valve factory mounted at EIKLOR FLAMES�: Yes No Gas type: Natural Gas Liquid Propane Usage: Residential Commercial What is your fireplace des�n Front View See-Thru 3-Sided 4-Sided Your hand-written comments Purchased from Date of purchase: Name: City, State: Phone number: Installed� Name: City, State: Phone number: 282 E. Pivot Point Road Paoli, IN 47454 U..SA. Toll-Free: 888.295.5647 Phone: 812.723.3633 Fax: 8 I 2.723.5708 Website: www.eiklorFlames.com 0 �_����t a — �l-J � Page 15 of 15 EIKLOR FLAMES� Tech Support Hotline: 888.295.5647 i • 1.2 SPECIFICATIONS (Cont.) C 1 : 1---- D � I ' i /� � Tabie 2. Flue Sentinel Dimensions* ' ' � _- ��i��� ,� ____ ;; ,� � �, __ ___._--- � � -_. �� � > > �� fa ''�.. �� �� .__'�; �i - � / / I-- -- - A �,, �� i ��I-r � �. ,�� _; . -- E�_ , � PART NO. DIM. A DIM. B DIM. C DiM. D FS-8 7.5 10.5 15.25 13.5 FS-9 8.5 10.5 18.0 14.5 FS-10 9.5 10.5 19.0 15.5 FS-11 10.5 10.5 20.0 16.5 FS-12 11.5 10.5 21.0 17.5 FS-13 12.5 12.5 22.0 18.5 FS-14 13.5 12.5 23.0 19.5 FS-15 14.5 12.5 24.0 20.5 FS-16 15.5 12.5 25.0 21.5 'All dimensions are in inches. �� � f� E SEMTINEL 0100-00 Inspection Items for M10-0102 16:03 01/14/2013 Total Rows: 7 Page 1