Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A10-0040 void
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED �pp , Project #: ! ICJ 1 0—oz - .1 5 Building Permit #: Alarm Permit #: ©— 0D RO At 970- 479 -2135 (Inspections) TOWN OFVK TOWN OF VAIL FIRE ALARM PERMIT APPLICATION Commercial &Residential Fire Alarm shop drawings 75 S. Frontage Rd. a lication submittal and must include infor a i I' Vail, Colorado 81657 2 page of this form. Application will not be ep�eTwith�uf th`l� information. CONTRACTOR INFORMATION JUN 17 2010 I II � LJ TOWN QF VAIL Fire AI cXh Contractor: Town of Vail Reg. No.: Contact and Phone #'s: `7l E -Mail Address: h el Contractor Signature: COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materials) Fire Alarm: $ Contact Eagle County Assessors nff:. -A at q70 -328 -8640 or visit www. ea le -coup . com for Parcel # Parcel # 1 a 1 Date Received: Job N met Job Address: Accepted By: `l/ v [ Legal Description L0t __J1 Block: Filing: Subdivision: Ow ers Na _ A s koX 0 Phone: 7 � Engineer: Address: Phone: Detailed Location of work: (i.e., floor, unit #, bldg. #) — ;-P L r &A 2 Detailed description of work: [ Work Class: New( Addition ( ) Remodel( ) Repair)e Retro -fit ( ) Other ( ) Type of Bldg.: Single- family ( ) Two - family ( ) Multi- family Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation units in this building: Does a Fire Alarm Exist: Yes ) No( ) Does a Fire Sprinkler System Exist: Yes( ) No �: *ic�:a4 *8: % *�t�:r. = *ic iv #9t nF %iYXirXXak drtk4: �c * &:E r.$r. OFFICE USE Other Fees: Date Received: Public Way Permit Fee:: - Accepted By: Occupancy Group: \ \Vail\ data \cdev \FORMS \PERMrrS\ALRMPERM.DOC 07/26/2002 • ELECTR°NICSiNC E N T E R T A I N M ENT -SEC U R I T Y• FIRE Go Ahead - June 14, 2010 Vail Fire and Emergency Services Mike Vaughn 42 W Meadow Drive Vail CO 81658 RE: Lionsmaine Mike, E .T, Member ly e. WewpportanderKOww NICUcPr KatW We are seeking emergency installation of a dialer to the existing panel at Lionsmaine Phase one, 116 W Sandstone in Vail. The system is no longer being monitored by Vail Communications on the BANA line and has no other means of communication. The existing Nofifier SGL4000 has the alarm and trouble relays that are needed to connect to the Silent Knight 5104 dialer. Attached, please find the cut sheet for the 5104 dialer. Sincerely, Don Anderson NICET 119424 Phone: 970.827.9120 Fax: 970.827.9126 910 Nottingham Road, Unit N -1, Avon, CO 81620 Mailing: P.O. Box 3940, Avon, CO 81620 3 SILENT 5104B Fire Control KNIGHT Communicator by Honeywell The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field - tested operation. This six -zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines — eliminating the need for expensive leased line arrangements. Use it as a stand- alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard — the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800- 328 -0103. Model 51048 Fire Control Communicator The Silent Knight Model 51048 is a six -zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand -alone unit, it can be used to monitor. • Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions. • Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). • Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two -wire type smoke detectors, instead of the normal four -wire contact type, for automatic fire detection applications. Features • UL 864 Listed as an NFPA 72 Central Station or Remote Station protected premise unit. • FM approved. • Can be used as a stand -alone or as a add-on DACT. • Six fully supervised inputs: one Class A (Style D) input, and five Class B (Style A) inputs. • Downloadable for remote programming. • Fuseless overload protection with automatic reset circuitry and fault indicators — eliminates the cause of most field calls. M«" 51041111 • Dual phone line interface Automatic self tests every 24 hours with report sent to central station. • Reports in SIA and most major communications formats. • 60 hours of standby power. • Operates on loop start phone lines ahead of the building PBX system. • A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). 5104B Fire Control Communicator Specifications Electrical Add-on Applications - UL Listed Input 120 VAC 60 Hz 40 watts Current: Standby 50 mA Alarm 135 mA Stand Akre Applications Input: 120 VAC 60 Hz 40 watts Standby: 12 volt 7 amp hour rechargeable battery 5230 Remote Annunciator (three maximum per system) Load: 60 mA standby 120 mA alarm Indicator Lights (LEDs): Power On (Green) Trouble Silenced (Yellow) Until Trouble is Cleared/Flashing = Supervisory Dialer Failure (Yellow) Telephone Line Fault (2 Red) Inside Cabinet at Li and L2 Inputs Telephone Requirements: FCC Registration #: AC698R- 17462 -AL-E RINGER EQUIVALENCE 0.08 Type of Jack: RJ31X (2 required) R-F"W 777777 C01EF [' ^ F3�Kl Mechanical: Dimensions: 12.25" W x 14.5" H x 3.0" D (31.1 cm W x 36.8 cm H x 7.6cm D) Weight: 15 lbs. (6.75 kg) Color: Red Optional Accessories: 5230 Remote Annunciator/Programmer 5561 Download Package 7181 Fire Zone Converter Module 7860 Telephone Connecting Cord for RJ31X Jack (2 required) 6712 12 volt, 7AH rechargeable battery Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK 4/2, Radionics BFSK Approvals: UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service. FM Approved CSFM Approved MEA Model 5230 Remote Alphanumeric Annunciator The 51048 can be programmed through the use of the optional Model 5230 Remote Alphanumeric Annunciator. Programming options include: telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, user and installer codes. System programming is stored in a non- volatile EEPROM chip which is reprogrammable hundreds of times. The 51048 accommodates up to three remote annunciators via a four -wire connection. A quick - connect plug allows temporary connection of the annunciator for programming. The Model 5561 SKSS Downloading Package Allows for remote programming and status checking of the 5104. Includes a 3 1/2 -inch disk and Silent Knight proprietary modem. Allows the installing company to view the default programming, modify it, and if necessary, troubleshoot the system. Designed to be used on an IBM or compatible PC. The downloading software also contains programs for other Silent Knight downloadable products. 51/4 -inch disks available upon request. 5104B Fire Control Communicator 120VAC 60 Hz UL-LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 51048 6 Channel Communicator MODEL 5104B BLOCK DIAGRAM Add -On DACT Application Tel. Line #2 SILENT KNIGHT MODEL 5104B 120VAC 60 Hz Class A Input (supervised) �— Max 5 waterflow devices as per NFPA 72 Class B Inputs Silent Knight (supervised) Model 5230 Gate valve tamper or PIV supervisor - must connect (optional) normally open LE Alarm Contact Model 5230 (optional) Remote Annunciator (3 max per system) Trouble Contact, Tel. Line #1 To RJ31X 6 Channel Silent Knight Communicator Model 5230 (optional) Remote Annunciator (3 max per system) Tel. Line #1 12 Model 6712 Model To RJ31X 7 Tel. Line #2 MODEL 51048 BLOCK DIAGRAM Stand -alone Waterflow Application 0 Wheelock MB-G10 -12-R 5104B Fire Control Communicator SILENT KNIGHT MODEL 5104B 120VAC 60 Hz Class A Input (supervised) Class B Inputs (supervised) Heat detectors, manual pull stations and contact type smoke detectors C C 6 Channel Silent Knight Model 5230 Communicator (optional) Remote Annunciator (3 max per system) Model 6712 12VDC 7 AH Tel. Line #2 Tel. Line #1 MODEL 5104B BLOCK DIAGRAM To RJ31X 0 Wheelock MS- G10 -12 -R (optional) Stand -alone Automatic Fire Detection Application (For Communication Only) ARCHITECTIENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary telephone line (number) at alternating supply shall be capable of supplying approved digital communicator to 24-hour intervals in accordance with power, under maximum normal load, transmit the fire alarm and supervisory NFPA 72. It shall sound a local trouble for 24 hours for central station or and trouble signals to a central station. signal if the telephone service is proprietary applications or 60 hours for The digital communicator shall be UL interrupted for longer than 60 seconds remote supervising station system or FM listed for fire reporting to a and it shall transmit a signal indicating application in accordance with NFPA central station and shall conform to the the loss of phone line service to the 72. requirements of NFPA 72. central station over the remaining The communicator shall be able to The digital communicator shall provide phone line. A signal shall also be transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format (Security Industry Association). six supervised detection circuits. One phone service. The The alarm signals transmitted the shall be Class A (Style D) and five shall control/communicator shall be able to central station shall indicate whi ch of be Class B (Style A). The detection report the loss of either phone line the six zones is in alarm and which circuits shall accommodate sprinkler without regard to which phone line zones are in trouble. R al from flow switches, gate valve supervisory failed first If both lines fail, a local ca alarm trouble shall capable of ca switches, thermal detectors and signal shall sound. communicating to Silennt t Knight, and contact-type smoke detectors intermixed as desired and permitted by interm The control/communicator shall have other industry standard receivers. NFPAixe the ability to send a test signal to the central station every 24 hours. The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines, seize the phone line setting a program within the panel. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to -date and accurate. We cannot cover all IC1�tIGH T specific applications or anticipate all requirements. All specifications are PN 350349, Rev C 3 subject m change without notice. For more information, contact Silent Knight 02010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472 -1610. Phone: (800) 328-0103, Fax: ( 203) 484 -7118. www.stientimight.00m