Loading...
HomeMy WebLinkAboutASB06-0018TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ASBESTOS Permit #: ASB06 -0018 Job Address: 442 S FRONTAGE RD WEST VAIL Location.......: APOLLO PARK Parcel No....: 210108246023 Legal Description: 1� 123 UCH — C;O `( 7 Project No .: ?? OWNER RON BYRNE 285 BRIDGE ST VAIL CO 81657 APPLICANT VEOLIA ES SPECIAL 5098 PARIS ST. DENVER COLORADO 80239 License: 738 -S CONTRACTOR VEOLIA ES SPECIAL 5098 PARIS ST. DENVER COLORADO 80239 License: 738 -S 08/16/2006 SERVICES, 08/16/2006 Status ...: ISSUED Applied ..: 08/16/2006 Issued ...: 09/08/2006 Expires ...: 03/07/2007 Phone: (303) 371 -7600 SERVICES, 08/16/2006 Phone: (303) 371 -7600 Desciption: MOUNTAIN VIEW RESIDENCES - COMPLETE GUT OF ALL DRYWALL AND LINOLEUM Occupancy: Type Construction: Type Occupancy: ?? Valuation: $300,000.00 Add Sq Ft: 0 Fireplace Information: Restricted: # of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0 FEE SUMMARY Building > $58.00 Total Calculated Fees - -> $116.00 Plan Check - - -> $58.00 Additional Fees ---------- > $0.00 Investigation -> $0.00 Total Permit Fee --------- > $116.00 Payments-------- ----- -- - - -- > $116.00 TOTAL FEES ------------- > $116.00 BALANCE DUE --------- > $0.00 Approvals: Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 08/24/2006 DRhoades Action: APPR Approved as submitted. An inspection is required prior to work starting but after set up. Contractor shall provide four (4) full sets of protective gear for VFES to be used in an emergency response. See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residentail Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE FORTY -EIGHT HOURS IN ADVANCE BY TELEPHONE AT 970 -479 -2135 OR 970- 479 -2252 SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF PAGE 2 CONDITIONS OF APPROVAL Permit #: ASB06 -0018 as of 05 -03 -2007 Status: ISSUED Permit Type: ASBESTOS Applicant: VEOLIA ES SPECIAL SERVICES, INC. (303) 371 -7600 Job Address: 442 S FRONTAGE RD WEST VAIL Location: APOLLO PARK Parcel No: 210108246023 Description: MOUNTAIN VIEW RESIDENCES - COMPLETE GUT OF ALL DRYWALL AND LINOLEUM Conditions: Cond: 38 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479 -2250. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Applied: 08/16/2006 Issued: 09/08/2006 To Expire: 03/07/2007 61 ✓f 6 eo APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI �:_ -> t y ; Project #• Building Permit #: Asbestos Permit #. t 'f'5t'0(. V-W/8 TOWN OF VAIL ASBESTOS ABATEMENT PERMIT APPLICATION MWN OF YAII. Required per Ordinance No. 19, Series of 1998 75 S. Frontage Rd. Vail, Colorado 81657 Permit application will not be accepted without the following: 1. Copies of General Abatement Certificate and State of Colorado Certification 2. A copy of written arrangements with the facility operators for any temporary disabling of the air handling systems, fire sprinkler system, and alarm systems with the names and contact phone numbers of these individuals. 3. Site plan with details addressing: waste container storage location. waste load out area location. entry and exiting details of abatement area. details of entry and exiting plans for the occupants of the structure in unaffected areas. 0.0% nwr"rnn TKICADMATTAN On Site Abatement Contractor: Town of Vail' Reg. No.: C H�✓ uv4N 's: �3g- S -3 ?� 7�oa o� 303 -7�5� X757 E -Mail Address: F ✓A V%I ci 0 Contractor Signature: gfA r w_ COMPLETE VALUATION FOR ASBESTOS ABATEMENT PERMIT (Labor & Materials) Asbestos Abatement: $ 5a a � -Fjs of •f A dl--An i.r .1A0, 1AAA11A1 aan1a -rn1 m tV cnm for Pa Me/ # conracr Ea le LOUMY AS.5 =1WI D W,,.t,� A. „ Lf .00-.- Palrcel , Job Name: A P O LU YAO-v,— a� C Job Address: yya -0�7A L Zb Legal Description Lot: Block: Filing: Subdivision: Owners Name: L't Addres%25 c T fQll Alai Phone: Project Manager: Address: ,, 4 rt .t IL' -A �� i 5T. �9n1 vr. c� Fl�231 Phone: - 7 - 7G p a 0 - Project Designer: V� -47 j p-0— Address: i � Phone: Air Monitoring Specialist: Address: A �' - Phone: S03 _ 1 _ & ATE BS�� �C aL5 rc .- Gen �inont cc, &>112- Detailed description of work: � Gem ; - e- � o,.11 AV Wktl aOA WA01eu Start Date: 9 _ Q U I End Date: Start Time: ; Quit Time: 5 : 06 P. Amount of Asbestos: Linear Feet: Square Feet: Zoe 55 /Gal Drums: Work Class: New( Addition( ) Remodel( ) Repair ( ) Demo ( ) Other ( ) Work Type: Interior (,vC) Exterior ( ) Both( ) T of Bld .: Single-family Two-family Multi-family Commercial Restaurant Other Does a Fire Alarm Exist: Yes( ) No (X) Doe F in tem Exist: Yes( .) No Ela- VIER) OFFICE USE ONLY * * * * Appiroy Noted f . , Date Received. Public Wa •Permit Fee: Acce ted B F: \cdev\ FORMS \PERM 1TS \Fire \asbestos —perm_12 -5 -05. DOC Date: Page 1 of 1 A �wNoFynII, . ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION • I have included the asbestos test and report with my building permit application. applicant signature date OR • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature date OR • The building was constructed after October 12, 1988. The date of construction was original construction date applicant signature date F: \cdev \FORMS\ Permits \Building \building—permiLDOC Page 4 of 16 02/09/2005 BUILDING PERMIT ISSUANCE TI FRAME If this permit requires a Town of Vail Fire Department Approval, Engineer's (Public Works) review and approval, a Planning Department review or Health Department review, and a review by the Building Department, the estimated time for a total review will take as long as three (3) weeks. All commercial (large or small) and all multi- family permits will have to follow the above mentioned maximum requirements. Residential and small projects should take a lesser amount of time. However, if residential or smaller projects impact the various above mentioned departments with regard to necessary review, these projects may also take three (3) weeks to review and approve. Every attempt will be made by this department to expedite this permit as soon as possible. I, the undersigned, understand the plan check procedure and time frame. I also understand that if the permit is not picked up by the expiration date, that I must still pay the plan check fee and that if I fail to do so it may affect future permits that I apply for. Agreed to by: /'�- // //,, s16- Print name Signature Project Name: Xd�'l /; /^ Vew Date: X12 , F: \cdev \FORMS\ Permits \Building \building Page 5 of 16 02/09/2005 L� TOWK O F VARIUL. MATERIAL STORAGE AND CONSTRUCTION PARKING Please read and check off each of the items below. (Copies of complete text are available upon request) CODE 5 -2 -10: DEPOSITS ON PUBLIC WAYS PROHIBITED ❑ Unlawful deposits: Subject to subsection C thereof, it is unlawful for any person to litter, track or deposit, or cause to be littered, tracked or deposited, sand, gravel, rocks, mud, dirt, snow, ice, or any other debris or material upon any street, sidewalk, alley or public place, or any portion thereof. ❑ Notice; Abatement: The Director of Public Works may notify and require any person who violates or causes another to violate the provision of subsection A hereof, or who has in the Director's employment a person who violates or causes another to violate the same, top remove such sand, gravel, rocks, mud, dirt, snow, ice or any other debris or material within twenty four (24) hours after receipt of said notice by the Director of Public Works. In the event the person so notified does not comply with the notice within the period of time herein specified, the Director of Public Works, or other authorized agent, may cause any such sand, gravel, rocks, mud,, dirt, snow, ice, debris or any other material to be removed from any street or alley at the expense of the notified. ❑ Summons and Penalty: As an alternative to the notice for removal provided in subsection B above, any person who violates or causes another to violate the same, may be issued a summons to appear before the Municipal Court of the Town for said violations, and upon being found guilty of a violation hereunder be punished as provided in Section 1 -4 -1 of this code. ❑ Notice and Penalty: It is unlawful for any person to fail or refuse to comply with the notice of the Director of Public Works as provided in subsection B hereof, and any such person shall, in addition to payment of the expense of removal incurred by the Director of Public Works, as provided in subsection B hereof, upon being found guilty of a violation hereunder, be punishable as provided in Section 1 -4 -1 of this Code. (1997 Code: Ordinance 6 (1979). CODES 7 -3A -1 AND 7 -3A -3: PARKING OBSTRUCTING TRAFFIC & IMPOUNDMENT AUTHORIZED ❑ No person shall park any vehicle upon a street or at any other place within this Municipality in such a manner or under such conditions as to interfere with the free movement of vehicular traffic or proper street or highway maintenance. (Ord. 2(1968) § 1) ❑ Whenever any police officer finds a vehicle attended or unattended, standing upon any portion of a street or upon any place within this Municipality in such a manner as to constitute a violation of any section of this Article, or left unattended for a period of twenty four (24) hours or more and presumed to be abandoned under the conditions prescribed by Colorado Revised Statutes section 42 -4 -1102, as amended, the officer shall require the vehicle to be removed or cause it to be removed and placed in storage in the nearest garage or other place of safety designated or maintained by this Municipality, and the charges for towing and storage of such vehicle shall be charged to the owner of the vehicle in addition to a ten dollar ($10) impoundment charge. (Ord. 2(1968) § 3: Ord. 28(1981) § 1) I have read and will comply with the above code provisions: AlofA— % P Name �( ^//� Signature Position or Relationship to Project: / �j/ / �Cof Date Signed: G�Zf�U� ' Fleveryone/forms/bldperm7 F: \cdev \FORMS\ Permits \Building \building—permit.DOC Page 11 of 16 02104/2005 A S S O C I ATE S I N C. Environmental, Geotechnical and Materials Professionals 'J 7 7 442 South Frontage Road East Vail, Colorado ATC Project Number 35.17693.5296 Prepared for: Mr. Matt Hoster W.E. O'Neil Construction Company of Colorado Building 52, Denver West 14062 Denver West Parkway,, Suite 240 Golden, Colorado 80401 May 10, 2006 May 10, 2006 s Mr. Matt Hoster W.E. O'Neil Construction Company of Colorado Building 52, Denver West �{ 14062 Denver West Parkway, Suite 240 �J Golden, Colorado 80401 Re: Asbestos Survey Report �j Apollo Park Lodge 442 South Frontage Road East Vail, Colorado ATC Project Number 35.17693.5296 Dear Mr. Hoster: 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112-3410'. www.atc- enviro.conr TEL: 303.799.6100 FAX. 303.799.3441. In accordance with ATC Associates Inc. (ATC) Proposal Number 35 =06- 0074 -E, dated March 22, 2006, ATC is pleased to submit this Asbestos Survey Report for the above - referenced site. This report documents the procedures and methodologies utilized by ATC, laboratory analytical results, and applicable conclusions and recommendations. This report is certified to W.E. O'Neil Construction Company of Colorado. ATC appreciates the opportunity to perform these services for W.E. O'Neil Construction Company and we look forward to working with you in the future. In the meantime if you have questions or comments regarding the information in this report or if we can be of further assistance please contact the ATC Centennial, Colorado office at (303) 799 -6100. Sincerely, ATC Associates Inc. c � Todd Anderson William E. Schwake, P.G. Project Manager Operations Manager SAPROTECTSU5.17693_WE ONeil Construction Co \442 S Frontage Rd E, VaiL CO Asbestos Survey doc APPENDIX B: INSPECTOR AND LABORATORY ACCREDITATIONS J J J S.IPROJECTSl15.17693 WE O'Neil Construction C6442 S Frontage Rd E, Vail, CO Asbestos Surcey.doc LETTER OF TRANSMITTAL 1.0 PURPOSE AND SCOPE OF SERVICES .................. ............................... I 2.0 GENERAL SITE CONDITIONS .................................................... ..... ..........................2 3.0 REPRESENTATIVE ASBESTOS - CONTAINING MATERIAL SURVEY .......... 3 3.1 Homogeneous Areas ....................................................................... ..............................3 3.2 Hazard Assessment Factors ..... ............................... ....:........................3 3.3 Sampling Strategy 3.4 Suspect Asbestos - Containing Material .......................................... ..............................5 s 3.5 Laboratory Analytical Results ..................................................... ............................... I 1 4.0 CONCLUSIONS AND RECOMMENDATIONS........... .............. .............................13 5.0 ASSUMPTIONS AND LIMITATIONS ........................................ .............................17 APPENDICES APPENDIX A: LABORATORY ANALYTICAL RESULTS APPENDIX B: INSPECTOR AND LABORATORY ACCREDITATIONS J J J S.IPROJECTSl15.17693 WE O'Neil Construction C6442 S Frontage Rd E, Vail, CO Asbestos Surcey.doc Apollo Park Lodge 442 South Frontage Road East Vail, Colorado ATC Project Number 35.17693.5296 ':- ! 1.0 PURPOSE AND SCOPE OF SERVICES J The purpose of this project was to conduct an asbestos survey of the Apollo Park Lodge buildings C and D located at 442 South Frontage Road East, Vail, Colorado, hereinafter referred to as the site. The survey was conducted in accordance with ATC's written Proposal Number 35 -06- 0074 -E, dated March 22, 2006. On April 27, 2006, ATC provided the services in accordance with the referenced agreement, and as outlined below: Conduct an asbestos survey in the identified buildings, which includes the following: 1. Review existing asbestos reports for the buildings, if available. 2. Survey the site buildings scheduled for demolition. 3. Identify accessible suspect asbestos - containing materials (ACMs) in the building interiors, exteriors and roofs using United States Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act (AHERA) protocols. 4. Collect and analyze bulk samples of suspect friable and non - friable materials to eliminate suspect materials as asbestos containing. SAPROIECTS'35.17693_WE O'Neil Construction CdA42 S Frontage Rd E, Vail, CO-Asbestos Survey.doc J 1 2.0 GENERAL SITE CONDITIONS The site is located at 442 South Frontage Road East in Vail, Colorado. The buildings are I three story wood framed structures with stucco exteriors and concrete foundations that 7 l fl 1 7 7 7 J 3 7 7 I were constructed in 1978. The buildings consist of approximately 29,800 square feet of space. Samples collected from the buildings included drywall and associated joint compound, sheet flooring, ceiling tiles, acoustical ceiling texture, sink undercoating, cove base adhesive, pipe insulation sealant, stucco, exterior sealant, roofing materials, carpet mastic, wall texture, ceramic tile adhesive, flange gaskets, and roof tar. SAFRO]ECTS135.17693 WE ONeil Constriction Cd442 S Frontage Rd E, Vail, CO — Asbestos Survey.doc 2 ATC representatives, Mr. Josh Lewis and Mr. Todd Anderson AHERA and Colorado - certified asbestos building inspector (certification number 2157) conducted the asbestos survey at buildings C and D located at 442 South Frontage Road East in Vail, Colorado. Previous ACM survey reports were not made available for review. The building was visually inspected for the presence of building materials that are suspected to contain asbestos. Bulk samples of identified suspect ACMs were collected and placed into individual containers for transport to a National Voluntary Laboratory Accreditation J Program (NVLAP) /American Industrial Hygiene Association (AIHA)- accredited laboratory for analysis. Materials visibly identified as non - asbestos (fibrous glass, foam rubber, wood, etc.) were not sampled. The asbestos survey consisted of three basic procedures: 1) conducting a visual inspection of the structures; 2) identifying homogeneous areas (HAs) of suspect surfacing, thermal system insulation, and miscellaneous materials; and 3) sampling accessible friable and non - friable suspect materials. 3.1 Homogeneous Areas Prior to collecting any samples, HAs were identified and listed to develop a sampling strategy. A homogeneous sampling area can be described as one or more area of material that are similar in appearance and texture and that have the same installation date and function. The actual number of samples collected from each homogeneous sampling area may, vary, based on the type of material and the professional judgment of the inspector. 3.2 Hazard Assessment Factors From the list of suspect homogeneous materials, a physical assessment was performed for each material on the list. A physical assessment includes evaluating the condition, assessing S IPROJECTSl35.17693_lVE ONeil Construction Cd442 S Frontage Rd E, Vail, CO Survey doc 3 the potential for disturbance, and determining the friability of each material. Friability is a term used to describe the ease in which a building material inherently lends itself to disturbance. By definition, t friable t materials are those that can be crumbled or reduced to powder by hand pressure when dry. Each material on the list was further classified into one of three categories, which have specific sampling requirements for each category. Surfacing Materials: Refers to spray - applied or troweled surfaces such as plaster ceilings and walls, fireproofing, textured paints, textured plasters, and spray- applied acoustical surfaces: Thermal System Insulation: Refers to insulation used to inhibit heat gain or loss on pipes, boilers, tanks, ducts, and various other building components. Miscellaneous Materials: Refers to friable and non- friable products and materials that do not fit in any of the above two categories such as resilient floor covering, baseboards; mastics, adhesives, roofing material, caulking, glazing, and siding.. This category also contains wallboard, joint compound and ceiling tile. All confirmed ACMs were then assessed by their condition as good (intact), fair (damaged), or poor (significantly damaged) per Title 40 Code of Federal Regulations Part 763. Material with localized significant damage was also assessed as poor when observed. 3.3 Sampling Strategy Sample collection depends on the category that the HA falls into and the amount of material present, as follows: AHERA GUIDELINES FOR DETERMINING THE NUMBER OF SAMPLES TO TAKE HA CATEGORY HA SIZE SAMPLES REQUIRED Surfacing Materials <1,000 SF 3 1,000 -5,000 SF 5 >5,000 SF 7 or more Thermal System Insulation No Stipulation 3+ (Must also sample all repair patches) Miscellaneous Materials No Stipulation Per AHERA, these materials must be sampled "in a manner sufficient to determine whether or not they contain asbestos." SAPROJECTSU5.17693 WE O 'Neil Construction Cd442 S Frontage Rd E, Vail, CO Asbestos Survey.doc 4 If the analytical results indicated that all of the samples collected per HA did not contain asbestos, then the HA (material) would be considered a non -ACM. However, if the analytical results of one or more of the samples collected per HA indicate that asbestos is present in quantities of greater than 1 percent asbestos by weight (as defined by EPA), all of the HA (material) would be treated as an ACM regardless of any other analytical results. Materials that can visually be determined to be non - asbestos containing (i.e., fibrous glass, foam rubber, etc.) by the accredited inspector are not required to be sampled. Miscellaneous materials require adequately representative sampling, which is typically done by collecting at least three samples per material. Inspectors typically rely on other survey observations such as the condition, friability, and quantity of material to determine what would be a sufficient amount of samples to accurately evaluate the presence or absence of asbestos content. Actual collection of a bulk asbestos sample involves physically removing a small piece of material and placing it in a marked, airtight container. Sample containers are marked with a unique identification number, which is also noted in the field notes. t 3.4 Suspect Asbestos - Containing Material Seventy -nine (79) bulk asbestos samples were collected from the building and one hundred - sixteen (116) sample layers were analyzed by Polarized Light Microscopy (PLM) based on the of niber of distinct layers (materials) associated with each bulk sample. For example, floor tile and associated mastic are collected as one bulk sample but are analyzed as two distinct materials by the asbestos laboratory, as required by the NVLAP. A summary of identified, accessible suspect and confirmed ACMs follows: SAPRO]ECTS135.17693_WE ONeil Construction Cd442 S Frontage Rd E, Vail, CO Survey.doc J I TABLE 1: - ASBESTOS SURVEY SAMPLING RESULTS APOLLO PARK LODGE .. 442 SOUTH FRONTAGE ROAD EAST VAIL, COLORADO MATERIAL LOCATION SAMPLE:: CONDITION FRIABLE QUANTITY ASBESTOS (CLASSIFICATION) OF'.. NUMBERS YES/NO (NESHAPS CONTENT SAMPLES : CATEGOR Drywall & Joint D -313 Storage 1 Good No Where present on Drywall -ND Compound (M) Closet seams and nail Joint holes Compound- (Cat. 11) 2 % Chrysotile Drywall & Joint D -2 2 Good No Where present on Drywall -ND Compound (M) Housekeeping seams and screw Joint Supply Room holes Compound- (Cat.II) 2% Chrysotile Drywall & Joint D -110 Storage 3 Good No Where present on Drywall -ND Compound (M) Closet seams and screw Joint holes Compound- (Cat.II) 2% Chrysotile Drywall & Joint C- Linens 4 Good No Where present on Drywall -ND Compound (M) Room, seams and screw Joint Garden Level holes Compound- (Cat.II) 2% Chrysotile Drywall & Joint C -204 Storage 5 Good No Where present on Drywall -ND Compound (M) Closet seams and screw Joint holes Compound - (Cat.11) 2% Chrysotile Drywall & Joint C -1 6 Good No Where present on Drywall -ND Compound (M) Housekeeping seams and screw Joint Supply Room hole Compound- (Cat. 11) 2% Chrysotile Drywall & Joint D- Electrical 7 Good No No Applicable Drywall -ND Compound (M) Room, Garden Joint Level Compound- -` ND White Sheet Flooring— D -314 8 Good No Approximately40 Layer 1 -ND, 2" x 2" Pattern Over Kitchen Square Feet Layer 2 -ND Multiple Layers (M) (Cat. I) Layer 3 -60% Chr sotile White Sheet Flooring— D -111 9 Good No Not Applicable Layer I -ND 2" x 2" Pattern Over Bathroom Layer 2 -ND Multiple Layers (M) Layer 3 -ND Layer 4 -ND White Sheet Flooring— C2- Studio 10 Good No Approximately30 Layer 1 -ND 2" x 2" Pattern Kitchen Square Feet Layer 2 -60% Multiple Layers (M (Cat. I) Chrysotile Layer 3 -ND J SAPROJECTSV5.17693_AT O'Neil Construction C6442 S Frontage Rd E. Vail, CO Asbestos Survey.doc 6 T S TROJECTS'J5.17693 WE 07461 Construction C6442 S Frontage Rd E, Vail, CO Asbestos Survey.doc 7 = ` .TABLE 1:._ ASBESTOS SURVEY SAMPLING RESULTS APOLLO PARK LODGE 442 SOUTH FRONTAGE ROAD EAST VAIL, COLORADO :..: _. MATERIAL LOCATION SAMPLE'. CONDITION FRIABLE QUANTITY. ASBESTOS (CLASSIFICATION) OF NUMBERS YES/NO (NESHAPS " . CONTENT SAMPLES CATEGOR Acoustical Ceiling D -207 Living 11 Good No" Approximately 5% Texture (S) Room 550 Square Feet Chrysotile (RACM) Acoustical Ceiling D -212 Living 12 Good No Approximately 5% Texture (S) Room 550 Square Feet Chrysotile CM Acoustical Ceiling D -112 13 Good No Approximately 8% Texture (S) Bedroom 550 Square Feet Chrysotile (RA CM) Acoustical Ceiling D- Hallway 14 Good No Approximately 5% Texture (S) Garden Level 200 Square Feet Chrysotile RACM Acoustical Ceiling., C -102 Living 15 Good No Approximately 5% Texture (S) Room 550 Square Feet Chrysotile (RA Acoustical Ceiling C -203 16 Good No Approximately 5% Texture (S) Bedroom 350 Square Feet Chrysotile (RA Acoustical Ceiling C -201 Living 17 Good No Approximately 5% Texture (S) Room 550 Square Feet Chrysotile RACIVI 2' x 4' Fissured Ceiling C- Laundry 18 Good Yes Not Applicable ND Tile (M) Room 2' x 4' Fissured Ceiling C- Laundry 19 Good Yes Not Applicable ND Tile (M ) Room 2' x 4' Fissured Ceiling C2— Studio 20 Good Yes Not Applicable ND Tile (M) Living Room Sink Undercoating, D -314 21 Good No One Sink 5 % Black (M ) Kitchen Cat. i Chrysotile Sink Undercoating, D -208 22 Good No One Sink 5 %. Black M Kitchen (Cat. 1) ChrVsotile Sink Undercoating, D -110 23 Good No One Sink 5% Black M Kitchen Cat. I Chr sotile Cove Base Adhesive (M) D -314 Kitchen 24 Good No Not Applicable ND Cove Base Adhesive (M) D -110 25 Good No Not Applicable ND Bathroom Cove Base Adhesive (M) CI-Studio 26 Good No Not Applicable ND Bathroom Pipe. Insulation Sealant, C- Boiler 27 Good No Not Applicable ND White (M) Room Pipe Insulation Sealant, C- Boiler 28 Good No Not Applicable ND White (M) Room Pipe Insulation Sealant, C- Boiler 29 Good No Not Applicable ND White (M) Room Stucco (S) Exterior 30 Good No Not Applicable ND D- Breezeway near 307 Stucco (S) Exterior 31 Good No Not Applicable ND D- Breezewa S TROJECTS'J5.17693 WE 07461 Construction C6442 S Frontage Rd E, Vail, CO Asbestos Survey.doc 7 7 1 7 7 '1 TABLE 1:. ASBESTOS SURVEY SAMPLING RESULTS APOLLO PARK LODGE 442 SOUTH FRONTAGE ROAD EAST VAIL,; COLORADO: MATERIAL LOCATION SAMPLE CONDITION. FRIABLE' QUANTITY.: ASBESTOS (CLASSIFICATION) ` OF NUMBERS :(NESHAPS' CONTENT SAMPLES . ::.'% : �: , "', CATCATEGORY) Stucco (S) Exterior 32 Good No Not Applicable ND D- I 10 Balcony Stucco (S) Exterior 33 Good No Not Applicable ND C-Breezeway Stucco (S) Exterior 34 Good No Not Applicable ND South Wall Stucco (S) Exterior 35 Good No Not Applicable ND C-203 Balcony Stucco (S) Exterior 36 Good No Not Applicable ND C-Breezeway near 301 Sealant (M) C-South 37 Good No Not Applicable ND Exterior Wall Sealant (M) C-South 38 Good No Not Applicable ND Exterior Wall Sealant (M) C-South 39 Good No Not Applicable ND Exterior Wall Roofing Materials (M) Roof Building 40 Good No Not Applicable ND C Roofing Materials (M) . Roof Building 41 Good No Not Applicable ND C Roofing Materials (M) Roof Building 42 Good No Not Applicable ND C Carpet Mastic (M) D-Breezeway 43 Good No Not Applicable ND near 307 Carpet Mastic (M) D- I 10 Balcony. 44 Good No Not Applicable ND Carpet Mastic (M) C-Garden 45 Good No Not Applicable ND Level Breezewa Rough Wall Texture (S) D-314 46 Good No Approximately 3% Hallway 2,000 Square Feet Chrysotile (Cat. 11) Rough Wall Texture (S) D-210 Living 47 Good No Approximately 5% Room 1,750 Square Feet Chrysotile 4: (Cat 11) Rough Wall Texture (S) C-102 48 Good No Approximately 5% Kitchen 1,750 Square Feet Chrysotile (Cat. 11) Rough Wall Texture (S) C -203 Living 49 Good No Approximately 2% Room 1,750 Square Feet Chrysotile (Cat. 11) Rough Wall Texture (S) C-204 50 Good No Approximately 5% Hallway 1,750 Square Feet Chrysotile (Cit. 11) Rough Wall Texture (S) C-302 Closet 51 Good No Approximately 5% 2,000 Square Feet Chrysotile (Cat. 11) Rough Wall Texture (S) C-306 52 Good No Approximately 5 I Bedroom I 2,000 Square Feet 1 Chrysotile (Cat. 11) WROIECTSU5.17693 O'Neil Construction Cck442 S Frontage Rd E, Vail, CO Survey.doc 8 i i J i i QUANTITY ASBESTOS (NESHAPS CONTENT CATEGORY) . Not Applicable ND Ceramic Tile Adhesive D -213 54 Good No TABLE 1; ND ASBESTOS SURVEY SAMPLING RESULTS Bathroom APOLLO :PARK LODGE 442 SOUTH FRONTAGE ROAD EAST Ceramic Tile Adhesive C -204 55 VAIL; COLORADO No MATERIAL LOCATION SAMPLE -, CONDITION .FRIABLE. (CLASSIFICATION) OF NUMBERS YES/NO Tan Sheet Flooring (M) C -203 Kitchen SAMPLES Good No Not Applicable Layer 1 -ND Ceramic Tile Adhesive D -314 53 Good No (M) Bathroom QUANTITY ASBESTOS (NESHAPS CONTENT CATEGORY) . Not Applicable ND S :IPROIECTSU5.17697 WE O'Neil Construction Cd442 S Frontage Rd E. Vail, CO Survey.doc 9 Ceramic Tile Adhesive D -213 54 Good No Not Applicable ND (M) Bathroom Ceramic Tile Adhesive C -204 55 Good No Not Applicable ND (M) Bathroom Tan Sheet Flooring (M) C -203 Kitchen 56 Good No Not Applicable Layer 1 -ND Layer 2 -ND Layer 3 -ND Layer 4 -ND Tan Sheet Flooring (M) C -203 56A Good No Approximately 40 Layer 1 -ND Kitchen Square Feet Layer -ND (Cat. I) Layer 3 -ND Layer 4 -60% Chrysotile Tan Sheet Flooring (M) C -203 Kitchen 57 Good No Not Applicable Layer 1 -ND Layer 2 -ND Layer 3 -ND Layer 4 -ND Tan Sheet Flooring (M) C -203 57A Good No Quantity Layer 1 -ND Kitchen represented by Layer 2 -ND sample 56A Layer 3 -ND (Cat. I) Layer 4 -60% ' Chrysotile Tan. Sheet Flooring (M) C -203 Kitchen 58 Good No Not Applicable Layer 1 -ND Layer 2 -ND Layer 3 -ND Layer 4 -ND Tan Sheet Flooring (M) C -203 58A Good No Quantity Layer 1 -ND Kitchen represented by Layer 2 -ND sample 56A Layer 3 -ND (Cat. 1) Layer 4-60% Chrysotile Tan & Brown Sheet D- Hallway 59 Good No Approximately Layer 1 -ND Flooring (M) Garden Level 200 Square Feet Layer 2 -65% �< . Cat 1 Chr sotile Tan & Brown Sheet D- Hallway 60 Good No Quantity Layer 1 -ND Flooring (M) Garden Level represented by Layer 2 -65% sample above Chrysotile ( Cat 1 Tan & Brown Sheet C- Boiler 61 Good No Approximately 4 Layer 1 -ND Flooring (M) Room at Door Square Feet Layer 2 -65% to Studio C2 Cat Chrysotile Wall Texture (S) D- Hallway 62 Good No Approximately 3 %- Garden Level 600 Square Feet - Chrysotile Cat. I1 Wall Texture (S) D- Hallway 63 Good No Quantity 3 %- Garden Level represented by Chrysotile sample above Cat. l S :IPROIECTSU5.17697 WE O'Neil Construction Cd442 S Frontage Rd E. Vail, CO Survey.doc 9 i i TABLE L. ASBESTOS SURVEY SAMPLING RESULTS APOLLO PARK LODGE ..442 SOUTH FRONTAGE ROAD EAST VAIL, COLORADO . MATERIAL. LOCATION SAMPLE CONDITION FRIABLE QUANTITY ASBESTOS (CLASSIFICATION) OF NUMBERS YES/NO (NESHAPS CONTENT SAMPLES CATEGOR Wall Texture (S) D- Hallway 64 Good No Quantity 3 %- Garden Level represented by Chrysotile sample above Cat. II) Flange Gasket (M) Boiler Room 65 Good No Not Applicable ND Flange Gasket (M) Boiler Room 66 Good No Not Applicable ND Flange Gasket (M) Boiler Room 67 Good No Not Applicable ND Splatter Wall Texture (S) C2- Studio 68 Good No Not Applicable ND Hallwa Splatter Wall Texture (S) C2- Studio 69 Good No Not Applicable ND Closet Splatter Wall Texture (S) CI- Studio 70 Good No Not Applicable ND Closet Sink Undercoating, C -203 71 Good No One Sink 15 %- White M Kitchen Cat. I Chrysotile Sink Undercoating, C -204 72 Good No One Sink 15%_ White M Kitchen (Cat. 1) Chrysotile Sink Undercoating, C -302 73 Good No One Sink 15 %- White M Kitchen Cat Chr sotile Roof Tar (M) Roof Building 74 Good No Where present 5 %- C around metal Chrysotile flashing (Cat. 1 Roof Tar (M) Roof Building 75 Good No Where present 5 %- C around metal Chrysotile flashing Cat.I Roof Tar (M) Roof Building 76 Good No Where present 5 %- C around metal Chrysotile flashing Cat 1 Built -up Roofing (M) Roof over 77 Good No Where present 10%_ Linens around metal Chrysotile flashing (Cat I Built- up:Roofing (M) Roof over 78 Good No Not Applicable ND Linens Built -up Roofing (M) Roof over 79 Good No Not Applicable ND Linens ND = None Detect, M= Miscellaneous, S= Surfacing, T= Thermal System Insulation RACM= Regulated ACM, Cat. I= Category I Non - friable ACM, Cat. II= Category II Non - friable ACM. SAPROJECTSU5.17693_WE O'Neil Construction Cd442 S Frontage Rd E, Vail, CO_Asbestos Surcey.doc } 10 1 7 :l Additional ACM may be present on site in inaccessible or concealed spaces. These spaces include, but are not limited to, pipe chases, spaces between wall /ceiling /door (fire rated doors) /floor cavities, interior of mechanical components such as cooling tower, interior ducts, beneath foundation pads, etc. If future maintenance /renovation/demolition activities make these areas accessible, ATC recommends that a thorough assessment of these spaces be conducted at that time to identify and confirm the presence or absence of additional ACMs. Until then, all such unidentified materials should be treated as Presumed ACM (PACM) in accordance with 29 CFR 1926.1101 and 1910.1001. 3.5 Laboratory Analytical Results Bulk samples were analyzed by ATC's Analytical Laboratory located in Centennial, Colorado, using PLM according to EPA method 600/M4 -82 -020 or 600/R- 93/116. This laboratory participates in the NVLAP, a quality, assurance program for PLM, and is accredited by the National Institute of Standards and Technology (KIST), and The American Industrial Hygiene Association (AIHA). Any material that contains greater than 1 percent asbestos is considered an ACM and must be handled according to OSHA, EPA, and applicable state and local regulations. For friable materials, when the amount of asbestos in the sample material ' is reported as "None- Detected" by PLM analysis, no further verification of the sample results by Point Couri ng Methodology is recommended. For friable materials, when the amount of asbestos in the sample material is reported as "Trace Asbestos Detected" or less than 10 percent asbestos by PLM analysis, the client may J either assume the amount to be greater than 1 percent and treat the material as ACM or require further verification of the amount by Point Counting Methods. If the result obtained by the Point Counting Method is different from the result obtained by PLM analysis, .the Point Count Method result will be used. &VROJECTSM- 17693_WE ONeil Construction Cd,442 S Frontage Rd E, Vail, CO Survey. due 11 L For non-friable t materials, when the amount of asbestos in the sample material is reported at t� greater than one percent by PLM analysis, no further verification of the sample results by alternative methods of identification such as Transmission Electron Microscopy (TEM)- Chatfield is recommended. For non - friable materials, when the amount of asbestos in the sample material is reported as "Non- Detect" or "Trace Asbestos" by PLM analysis, due to the difficulty in analyzing "small, thin fibers" associated with vinyl /asphaltic or resinously bound materials, ATC recommends that these types of materials, which were reported an non -ACMs by PLM, be analyzed using TEM- Chatfield Method. Copies of the laboratory's Analytical Report and corresponding chain -of- custody documents are included in Appendix A. Results are reported in percent asbestos by volume and indicate the types of asbestos. Other common non - asbestos components may also be noted on the analytical reports. Inspector and laboratory accreditation are provided in Appendix B. 1 SAFR07ECTSW 17693_WE ONeil Construction Cd\442 S Frontage Rd E, Vail, CO_Asbestos Su[vey.doc 12 J The results of the asbestos survey onducted for the site buildings C and D located at 442 Y g South Frontage Road East, Vail, Colorado, indicate that the following building materials J were found to contain more than 1 percent asbestos by PLM analysis. J TABLE 2 ASBESTOS MANAGEMENT RECOMMENDATIONS : APOLLO PARK LODGE SOUTH FRONTAGE ROAD EAST • i VAIL, COLORADO Material Location of NES)3AP Friable - ...'..Recommendations Classification 'Material Cate o - Yes/No Joint Compound Throughout Cat. II No Continue O &M. Remove this Associated with Drywall Buildings C & D material prior to demolition in (M) accordance with Reg. 8, NESHAP & OSHA 29CFR1926.1101. Sheet Flooring, Backing Kitchens, Cat. I No Continue O &M. Remove this (M) Bathrooms material prior to demolition in Throughout accordance with Reg. 8, NESHAP & Buildings C & D, OSHA 29CFR1926.1101. Building C Studio. 2C & Building D Garden Level Hallway Acoustical Ceiling Throughout RACM Yes Continue O &M. Remove this Texture (S) Buildings C & D material prior to demolition in Except for the accordance with. Reg. 8, NESHAP & Third Level OSHA 29CFR1926.1101. Ceilings Sink Under Coatings Kitchen Sinks Cat. II No Continue O &M. Remove this Black & White (M) Throughout material prior to demolition in Buildings C & D accordance with Reg. 8, NESHAP & OSHA 29CFR1926.1101. Wall Texture (S) Throughout Cat. II No Continue O &M. Remove this _ Buildings C & D material prior to demolition in accordance with Reg. 8, NESHAP & OSHA 29CFR1926.1101. Roof Tar (M) Roofs, Around Cat. I No Leave in place during demolition in [ND Metal Flashing accordance with NESHAP & OSHA 29CFR 1926.1101 = None Detect, M= Miscellaneous, S= Surfacing, TSI= Thermal System Insulation, RACM= Regulated CM, Cat. 1= Category I Non - friable ACM, Cat. II= Category II Non - friable ACM ATC recommends that all of the ACMs identified in the tables above be. maintained under a written Operations and Maintenance (O &M) program, by suitably trained personnel, until renovation necessitates removal or until the building is demolished. SIPROJECTSU5.17693_WE ONeil Construction C 6.442 S Frontage Rd E. Vail. CO Survey.doc 13 1 . Subcontractors and employees working within the structures at the site should be made aware of the locations of the ACMs and the possibility of concealed suspect ACMs that could be found during renovation/demolition activities. They should be advised not to disturb the ACMs or PACMs. Any concealed building materials discovered during maintenance or renovation activities, which are suspected to contain asbestos, should be sampled and analyzed to confirm the presence of asbestos prior to the disturbing such materials. For friable materials, when the amount of asbestos in the sample material is reported as "Trace Asbestos Detected" or less than 10 percent asbestos by PLM analysis, the client may either assume the amount to be greater than 1 percent and treat the material as ACM or require further verification of the amount by Point Counting Methods. If the result obtained by the Point Counting Method is different from the result obtained by PLM analysis, the Point Count Method result will be used. The EPA has not prohibited the manufacture and import of miscellaneous materials, such as vinyl floorings, mastics, roofing materials, etc. As a result, any future replacement materials should be checked for the presence of asbestos prior to installation. The friable regulated ACMs (RACMs) and the Category II Non - friable materials (such as joint compound, wall texture etc.) that have a propensity to become friable during renoyation/demolition, identified in the tables above are recommended for removal by Colorado Department of Public Health and Environment (CDPHE) - licensed personnel in accordance with applicable regulations, prior to building demolition. Any Person intending to either abate asbestos - containing materials in any amount greater than the trigger levels, or demolish a facility shall, on a form supplied by CDPHE, provide a written notice of the intent to conduct asbestos abatement or demolition. No person shall commence an abatement project in which the amount of friable asbestos - containing material exceeds the trigger level in an area of public access without first obtaining a J permit from CDPHE. Permit fees will be required for asbestos abatement projects. J &TROJECfS135.17693_WE O 'Neil Construction Cd442 S Frontage Rd E, Vail, CO Survey.doc 14 J Non - friable, undamaged ACMs (such as floor tiles, mastics, roofing materials, etc.) are classified as National Emission Standard for Hazardous Air Pollutants (NESHAP) Category I, non-friable ACMs by the EPA. In accordance with the NESHAP, as long as such materials remain in a non - friable state and are not subjected to mechanical drilling, sanding, abrading, grinding, or sawing during demolition activities, they do not have to be removed prior to demolition, provided no visible emissions are generated during the demolition process. The following recommendations should be followed for demolition projects including contracting the services of an environmental consultant to monitor /document that the demolition contractor activities comply with the CDPHE, OSHA, EPA, NESHAP and applicable local city and county requirements. • The non - friable ACMs shall not be subjected to abrasion, grinding, sanding or any other processes during renovation/demolition, which will render these non - friable materials, friable. • When demolition by toppling occurs, adequate wetting shall be employed to suppress the dust and reasonable enclosures for dust emission control (as compatible with the - 1 building character) shall be employed. Non - friable ACM debris dislodged during demolition can be disposed off site in a sanitary landfill that accepts asbestos - containing demolition/construction debris wastes within the framework of local /state regulations. Please verify with the local landfills about their policies on accepting such wastes prior to planning the _7 demolition work. • Non- friable ACM debris mixed with demolition debris shall neither be used as fill material on -site nor shall it be sold/given away to others for the same use. S.TROJECTSU5.17693_WE 0 Construction Co\442 S Frontage Rd E, Vail, CO Asbestos Survey.doc 15 7 J S:TROJECTSUS. 17693WE O'Neil Construction Ca442 S Frontage Rd E, Vail, CO Asbestos Survey.doc l lb 1 • If the substrate (such as concrete) on which these non - friable ACMs are installed is intended for recycling, the non - friable ACMs shall be removed prior to the recycling ` process by a state - licensed asbestos abatement contractor prior to initiating substrate recycling activities. mean If the demolition contractor changes the s and methods of demolition and the environmental consultant is of the opinion that the Category I non - friable materials are being made friable, or if visible dust emissions are generated, the work should be stopped. In these situations, revised notification for removal of non - friable ACM may _ become necessary -and the removal work will then need to be done by a CDPHE licensed abatement contractor. 7 J S:TROJECTSUS. 17693WE O'Neil Construction Ca442 S Frontage Rd E, Vail, CO Asbestos Survey.doc l lb 1 The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during the ATC inspection of buildings C & D located at 442 South Frontage Road East, Vail, Colorado. Buildings A & B were not included in this survey. ATC's selection of sample locations and frequency of sampling was based on ATC's observations and the assumption that like materials in the same area are homogeneous in content. The report is designed to aid the building owner, architect, construction manager, general contractors, and potential asbestos abatement contractors in locating ACM. Under no circumstances is the report to. be utilized as a bidding document or as a project specification document since it does not have all the components required to serve as an Asbestos Project Design document or an Abatement Workplan. Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other - statements either expressed or implied. This report does not warrant against future J operations or conditions, nor does it warrant against operations or conditions present of a type or at a location not investigated. This report is certified to W.E. O'Neil Construction Company. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users, and use or re -use of this document or the findings, conclusions, or recommendations is at the risk of said user. SAPROJECTSU5 17693_WE O'Neil Construction Cw442 S Frontage Rd E, Vail, CO Asbestos Survey.doc 1 17 f APPENDIX A LABORATORY ANALYTICAL RESULTS 1 J l 1 1 I SAPROJECTSU5.17693 WE ONeil Construction Cd442 S Frontage Rd E, Vail, CO Asbestos Survey.doc J ANALYTICAL REPORT Prepared for: W.E. O'Neil Construction Company Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Project: Asbestos Survey '� Orderfl: 0006842 _� Report Date: 05/03/2006 A TC A SSOCL4 TES, INC 8985 E. Nichols Avenue, Suite 350, Centennial, CO 80112 Ph: 303-799-6100 ' 8985 E. Nichols Avenue Suite 350 Centennial, CO 80112 � " www.atc- enviro.com ._ ; 303.799,6100. Fax 303.799.3441 - PLM REPORT. SUMMARY AIVLAP Lab Code AIHA Lab Code 101536 1536 Client: Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 J Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600�Iv14= 82- 020;'600/R- 93/116 Page 1 of 16 Client No. Lab No. Sample Description / Location Asbestos Content 1' 0006842 -001 LAYER 1 Chrysotile 2% Joint Compound, Tan l Note: Overall <l %Chrysotile 3rd Floor, D -313, Storage Closet 1 0006842 - 001 LAYER 2 None Detected Drywall, White/ Tan Note: Chrysotile associated with joint compound 3rd Floor, D -313, Storage Closet 2 0006842 - 002 LAYER I Chrysotile 2% Joint Compound, Tan Note: Overall: <I% Chrysotile 2nd Floor, D -2, Housekeeping Supplies 2 0006842 -002 LAYER 2 None Detected Drywall, White/ Tan Note: Chrysotile associated with joint compound 2nd Floor, D -2, Housekeeping Supplies' v 3 0006842 -003 LAYER I Chrysolite 2% Joint Compound, Tan Note: Overall: <1% Chrysotile Ist Floor, D -110, Storage Closet 3 0006842 -003 LAYER 2 None Detected Drywall, White/ Tan Note: Chrysotile associated with joint compound Ist Floor, D -110, Storage Closet These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant: The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable — be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite 350. Centennial, CO 80112-- www.atc- enviro.com 303.799.6100 Fax 303.799.3441 Client: PLM REPORT SUMMARY Matthew Hoster ATC Job No.: 35.17693.5296 ` W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 J Client No. Lab No. Sample Description /Location NVLAP Lab Code 102031 AIHA Lab Code 101536 Page 2 of 16 Asbestos Content 4 0006842 -004 LAYER I Chrysotile Joint Compound, Tan 0006842 -005 LAYER 2 Note: Overall: <I% Chrysotile Drywall, White/ Tan Ground Floor, C- Linens Room Note: Chrysotile associated with joint compound 2nd Floor, C -204, Storage Closet 4 0006842 -004 LAYER 2 None Detected Joint Compound, Tan Drywall, White/ Tan Note: Overall: <1 %Chrysotile Note: Chrysotile associated with joint compound Ground Floor, C- Linens Room Ground Floor, C -1, Housekeeping Supplies 5 0006842 -005 LAYER I Chrysotile Drywall, White/ Tan Joint Compound, Tan _ Note: Chrysotile associated with joint compound Note: Overall: <I %Chrysotile Ground Floor, C -I, Housekeeping Supplies 2nd Floor, C -204, Storage Closet J 5' 0 0006842 -005 LAYER 2 Drywall, White/ Tan Note: Chrysotile associated with joint compound 2nd Floor, C -204, Storage Closet 6 0006842 -006 LAYER 1 Joint Compound, Tan Note: Overall: <1 %Chrysotile Ground Floor, C -1, Housekeeping Supplies 6 0006842 -006 LAYER 2 Drywall, White/ Tan Note: Chrysotile associated with joint compound Ground Floor, C -I, Housekeeping Supplies These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated f Asbestos Containing Materials (RACM) — materials which are friable or may become friable — be further analyzed by point counting when the results indicate I less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. JJ The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. None Detected 2% 2% Chrysotile None Detected 2% __.__.._... Client: PLM REPORT SUMMARY Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.• 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4-82-020; 600/R-93/116 8985 E. Nichols Avenue, Suite 350 Centennial, CO 60112 www.atc-envirwcom 303.799. 00 Fax 303.799.3441 NVLAP Lab Code 102031 - ---- AIHA Lab Code 101536 Page 3 of 1'6 These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibratid Visual Area Estimation (CVAE). EPA regulations also indicate that - Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable - be further analyzed by point counting when the results indicate J f less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in MI, and should not be used as a scope of work for abatement without consulting with ATC. JII Client No. Lab No. Sample Description Location Asbestos Content 0016142-011 LA * YER I Joint Compound, Tan None Detected -.5 Ground Floor, D-Electrical Room 7 0006842-007 LAYER2 None Detected 31 1 1 Drywall, White/ Tan Note: Chrysofile associated with joint compound Ground Floor, D-Electrical Room 8 0006842-008 LAYER I None Detected Linoleum Backing, Gray/ White Note: None Detected-Vinyl Surface, Adhesiv;., 3rd Floor, D-314, Kitchen 8 0006842-008 LAYER 2 None Detected Linoleum Backing, Gray/ Cream Note: None Detected-Vinyl Surface, Adhesive 3rd Floor, D-314, Kitchen of 8 0006842-008 LAYER Chrysotile 60% Linoleum Backing, Gray/ Orange Note: None Detected-Vinyl Surface 3rd Floor, D-314, Kitchen 9 0006842-009 LAYER I None Detected Linoleum, White 1st Floor, D -111, Bathroom These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibratid Visual Area Estimation (CVAE). EPA regulations also indicate that - Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable - be further analyzed by point counting when the results indicate J f less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in MI, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite-350 Centennial, CO'80112- '!� www.atc- enviro com 303.799.6100 Fax 303.799.3441 NVLAP Lab Code 102031 PLM REPORT SUMMARY AIHA Lab Code ,.01536 J Client: ATC Job No.: 35.17693.5296 Matthew Hoster W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 Page 4 of 16 Client No. Lab No. Sample Description / Location Asbestos Content 0006842 -009 LAYER 2 None Detected Linoleum Backing, Gray ; a 1st Floor, D -111, Bathroom r 0006842 -009 LAYER 3 None Detected 9 Mastic, Brown 1st Floor, D -111, Bathroom 0006842 - 009 LAYER 4 None Detected `J 9 Leveling Compound, White Ist Floor, D -I 11, Bathroom 10 0006842 -010 LAYER 1 None Detected Linoleum Backing, Gray/ White J Note: None Detected -Vinyl Surface, Adhesive Ground Floor, C2- Studio, Kitchen 0006842 - 010 LAYER 2 Chrysotile 60% 10 Linoleum Backing, Gray/ Cream Note: None Detected -Vinyl Surface 2ti Ground Floor, C2- Studio, Kitchen ' - - - -- - -- — 0006842 - 010 LAYER 3 None Detected ]0 Linoleum Backing, Gray/ Brown Note: None Detected -Vinyl Surface, Adhesive i Ground Floor, C2- Studio, Kitchen l 0006842 -011 Acoustical Ceiling Texture, White Chrysotile 5 % J 11 2nd Floor, D -207, Living Room [T hese samples were analyzed by layers. Specific layer or com o Calibratcd t Visual t Area Estimation (CVAE). EPA regulat ons also indi a e Regulated ontaining only if it contains more than one percent asbestos i Asbestos Containing Materials (RACK -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate t . I less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite 350 Centennial CO. 80112 www.atc- enviro.com 303.799.6100 Fax 303.799.3441 NVLAP Lab Code 102031 PLM REPORT SUMMARY AIHA Lab Code 101536 `= Client: L, ATC Job No.: 35.17693.5296 Matthew Hoster W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 Page 5 of 16 Client No. Lab No. Sample Description / Location Asbestos Content J Chrysotile 5% l2 0006842 -012 Acoustical Ceiling Texture, White 2nd Floor, D -212, Living Room ; 8% 31 Acoustical Ceiling Texture, White Chrysotile 13 - 0006842 - 013 � ?? 1st Floor, D -112, Bedroom °J 0006842 - 014 Chrysotile 5% Acoustical Ceiling Texture, White 14 Ground Floor, D- Hallway, Garden Level I S 0006842 -015 Acoustical Ceiling Texture, White Chrysotile 5 % 1st Floor, C -102, Living Room 0006842 -016 Acoustical Ceiling Texture, White Chrysotile 5% 16 2nd Floor, C - 203, Bedroom 17 0006842 - 017 Acoustical Ceiling Texture, White Chrysotile 5% ____ — •- 1 2nd Floor, C -201, Living Room J 2'x4' Ceiling Tile, White, Fiss. None Detected 18 0006842 - 018 Ground Floor, C- Laundry Room 0006842 -019 2'x4' Ceiling Tile; White, Fiss. None Detected 19 -: Ground Floor, C Laundry Room 20 0006842 - 020 2'x4' Ceiling Tile, White, Fiss. None Detected _ Ground Floor, C2- Studio (Living Area) These samples were analyzed by Payers. Specific layer or component Calibrated VisualtArea Estimation (CVAE). EPA regulations also indicate material tha Regulated containing only if it contains more than one percent as bestos b Y Asbestos Containing Materials (RACM) — materials which are friable or may become friable — be further analyzed by point counting when the results indicate bestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. less than ten percent as The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. r- P 8985 E. Nichols Avenue, Suite 350 _ Centennial, CO 80112 www.atc-enviro.com... 303.799.6100 Fax 303.799.3441 PLM REPORT SUMMARY NVLAP Lab Code 10 Client: AIHA Lab Code 101536 36 Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company _ P Y Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden. CO 80401 Sample Date: 04/27/2006 J Project: Asbestos Survey Y Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 Page 6 of 16 Client No. Lab No. Sample Description Location Asbestos Content 21 0006842 -021 Sink Under Coating, Black Chrysotile 5% 1 3rd Floor, D -314, Kitchen 22 0006842 -022 Sink Under Coating, Black Chrysotile 5 % r; 2nd Floor, D -208, Kitchen 23 0006842 -023 Sink Under Coating, Black Chrysotile 5% Ll Ist Floor, D -110, Kitchen . l 24 0006842 -024 Cove Base Adhesive, Brown _ None Detected J 3rd Floor, D -314, Kitchen 25 0006842 -025 Cove Base Adhesive, Brown None Detected Ist Floor, D -110, Bathroom 26 0006842 -026 Cove Base Adhesive, Brown None Detected _' Ground Floor, C1- Studio Bathroom 27 0006842 -027 Pipe Insulation Sealant, White None Detected Ground Floor, C- Boiler Room 28 0006842 -028 Pipe Insulation Sealant, White None Detected Ground Floor, C- Boiler Room 29 0006842 -029 Pipe Insulation Sealant, White None Detected Ground Floor, C- Boiler Room (— These samples were analyzed by layers. Specific layer or component asbestos content is in when relevant. The EPA considers a material to be asbestos r containing only if it contains more than pne percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated l Asbestos Containing Materials (RACM) -- materials which are friable or may become friable — be further analyzed by point counting when the results indicate 1 ' less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. 1 The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 1 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 www.atc- enviro -&6rr 303.799.6100 Fax 303.799.3441 NVLAP Lab Code 102031 AIHA Lab Code 101536 PLM REPORT SUMMARY Client: Matthew Hoster ATC Job No.: 35.17693.5296 Identification: N/A W.E. O'Neil Construction Company Batch No.: 0006842 1 Test Method: Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006. Golden CO 80401 Sample Date: 04/27/2006 Sample Description / Location Asbestos Content Project: Asbestos Survey Date Analyzed: 05/03/2006 NVLAP Lab Code 102031 AIHA Lab Code 101536 These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACK -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. Client Project No.: Identification: N/A 1 Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 Page 7 of 16 Client No. Lab No. Sample Description / Location Asbestos Content 30 0006842 -030 Stucco, White/ Gray None Detected 3rd Floor, D- Breezeway Near 307 31 0006842 -031 Stucco, White/ Gray None Detected 1/2 Floor, D- Breezeway 32 0006842 -032 Stucco, White/ Gray None Detected Ist Floor, D =110, Bafcony 33 0006842 -033 Stucco, White/ Gray None Detected Ground/lst Floor, C- Breezeway ; 34 0006842 -034 Stucco; White/ Gray None Detected J Ground Floor, C- Exterior (South Wall) 35 0006842 -035 Stucco, White/ Gray None Detected r 2nd Floor, C-203-Balcony 36 7 0006842 -036 Stucco, White / Gray None Detected 3rd Floor, C- Breezeway Near 301 37 • 0006842 -037 Sealant, Green/ Red None Detected . -- Ground Floor, C -South Exterior Wall 38 0006842 -038 Sealant, Green/ Red None Detected J J Ground Floor, C -South Exterior Wall These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACK -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite 350 Centennial, CO 8011.2 www.atc- envirocom -- 303.799.6100 Fax 303.799.3441 J Client: PLM REPORT SUMMARY Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Dater 04/27/2006 J Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 I Client No. Lab No. Sample Description / Location NVLAP Lab Code 102031 AIHA Lab Code 101536 Page 8 of 16 Asbestos Content 39 0006842 -039 Sealant, Green/ Red None Detected J Ground Floor, C -South Exterior Wall 40 0006842 -040 Roofing Material, Black/ Brown/ White None'Detected v'•%' Roof, Roof Building C 41 0006842 -041 Roofing Material, Black/ Brown/ White None Detected Roof, Roof Building C 42 0006842 -042 Roofing Material, Black/ Brown/ White None Detected -� Roof, Roof Building C 43 0006842 -043 Carpet Mastic, Tan None Detected J 3rd _1 Floor, D- Breezcway Near 307 1 44 0006842 -044 Carpet Mastic, Tan None Detected 1st Floor, D-110, Carpet on Balcony 45 0006842 -045 Carpet Mastic, Tan None Detected Ground Floor, C -Garden Level Balcony 46 0006842 -046 Wall Texture, White Chrysotile 3% 3rd Floor, D -314 Hallway 47 0006842 -047 Wall Texture, White Chrysotile 5% 2nd Floor, D -210, Living Room These samples were analyzed y p y p zed b layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more'than onepercent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable — be further analyzed by point counting when the results indicate l less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 1 8985 E. Nichols Avenue, Suite 350 - • ::., .. Centennial, CO 80112 www.atc- enviro cam 1 J 303.799.6100 Fax 303.799.3441 PLM REPORT SUMMARY N�-� Lab Code 153 " AIHA Lab Code 101536 Client: Matthew Hoster ATC Job No.: 35.17693.5296 , �} W.E. O'Neil Construction Company Batch No.: 0006842 J Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 r Client Project No.: Identification: N/A Test Method: EPA. Method 600/M4 -82 -020; 600/R- 93/116 .. Page 9 of 16 Client No. Lab No. Sample Description / Location Asbestos Content iJ 48 0006842 -048 Wall Texture, White Chrysotile • 5% 1st Floor, C -102, Kitchen i 49 0006842 -049 Wall Texture, White Chrysotile 2% LJ 2nd Floor, C -203, Living Room " 50 0006842 -050 Wall Texture, White Chrysotile 5% - 2nd Floor, C -204, Hallway i. J 51 0006842 -051 .. Wall Texture, White Chrysotile 5% 3rd Floor, C -302, Closet 52 0006842 -052 Wall Texture, White Chrysotile 5 %- 3rd Floor, C -306, Bedroom — 53 0006842 -053 Ceramic Tile Adhesive, Tan l Note: Ceramic Tile Not Analyzed J 3rd Floor, D -314, Bathroom Ceramic Tile Adhesive, Tan Note: Ceramic Tile Not Analyzed 54 0006842 -054 2nd. Floor, D -213, Bathroom 55 0006842 -055 Ceramic Tile Adhesive, Tan Note: Ceramic Tile Not Analyzed 2nd Floor, D -204, Bathroom These samples were analyzed by layers_ Specific layer or component asbestos content is indicated when relevant: The EPA considers a material to be asbestos EPA regulations also indicate that Regulated J containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). friable or may become friable — be further analyzed by point counting when the results indicate Asbestos Containing Materials (RACivi) -- materials which are less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. ATC_ The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with 2nd Floor, C -203, Kitchen These samples were analyzed by layers. Specilic layer one percent asbestos by CalibratedtVisualtArea Estimation ti n (CVAE): EPA regulations also indicate material that Regulated stos Asbestos Containing Materials (RACM) - containing only if it con - materials which are friable or may become friable —tie further analyzed by point co unting when the results s teel. l i less than ten percent asbestos du by CVAE. eel exce O in full, lab and shou be u eel as a scope of work for es not i nt without o point consulting withsATCcificallyrequested. on a routine basis and � The results may not be rep r JJJ � 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 www.atc- enviro.com 303.799.6100 _ . Fax 303.799.3441 NVLAP Lab Code 102031 PLM REPORT SUMMARY AiHA Lab Code 101536 " J Client: ATC Job No.: 35.17693.5296 Matthew Hoster Batch No.: 0006842 W.E. O'Neil Construction Company Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 - L 1 Client Project No.: ;. Identification: N/A page 10 cf.16 3 EPA Method 600/M4 -82 -020; 600/R- 93/116 ` Test Method: No. Sample Description / Location Asbestos Content !� Client No. Lab J None Detected 56 0006842 - 056 LAYER 1 Sheet Flooring, Cream r 2nd Floor, C -203, Kitchen None Detected , t•t 56 0006842 - 056 LAYER 2 . Sheet Flooring Backing, Gray Note: None Detected- Mastic 2nd Floor, C -203, Kitchen LAYER 3 None Detected 56 0006842 - 056 Sheet Flooring, White 2nd Floor, C -203, Kitchen .' w None Detected 56 0006842 -056 LAYER 4 ' Sheet Flooring, Tan _ Note: None Detected - Mastic J 2nd Floor, C -203, Kitchen None Detected J 56A 0006842 - 057 LAYER 1 Sheet Flooring, Cream 2nd Floor, C -203, Kitchen -'- -- a' 2 None Detected 56A 0006842 - 057 LAYER Sheet Flooring Backing, Gray . . Note: None Detected- Mastic 2nd Floor, C -203, Kitchen None Detected 1 56A 0006842 LAYER 3 Sheet Flooring, Orange 2nd Floor, C -203, Kitchen These samples were analyzed by layers. Specilic layer one percent asbestos by CalibratedtVisualtArea Estimation ti n (CVAE): EPA regulations also indicate material that Regulated stos Asbestos Containing Materials (RACM) - containing only if it con - materials which are friable or may become friable —tie further analyzed by point co unting when the results s teel. l i less than ten percent asbestos du by CVAE. eel exce O in full, lab and shou be u eel as a scope of work for es not i nt without o point consulting withsATCcificallyrequested. on a routine basis and � The results may not be rep r JJJ � 8985 E. Nichols Avenue, Suite 350 Centennial, `CO 80112 www.ato-enviro com 303.799.6i00-__ Fax 303.799.3441 NVLAP Lab Code 102031 �] PLM REPORT SUMMARY AIRA Lab Code 101536 f Client Matthew Hoster ATC Job No.: 35.17693.5296 ^ W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A t ` Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 Page 11 of 16 Client No. Lab No. Sample Description / Location Asbestos Content 56A 0006842 -057 LAYER 4 Chrysotile 60% Sheet Flooring Backing, Gray 1 !r I Note: Mastic Inseperable 2nd Floor, C -203, Kitchen r� 57 0006842 -058 LAYER 1 None Detected Sheet Flooring, Cream 2nd Floor, C -203, Kitchen 0006842 -058 LAYER 2 None Detected 57 Sheet Flooring Backing, Gray Note: None Detected- Mastic 2nd Floor, C -203, Kitchen 57 0006842 -058 LAYER 3 None Detected Sheet Flooring, White 2nd Floor, C -203, Kitchen 57 0006842 -058 LAYER 4 None Detected Sheet Flooring, Tan �z Note: None Detected- Mastic ----- -- js 2nd Floor, C -203, Kitchen 0006842 - 059 LAYER 1 None Detected 57A Sheet Flooring, Cream - 2nd Floor, C -203, Kitchen :ere analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos These samples wa containing only by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated it contains more than one percent asbestos — be further analyzed by poinEcoun Asbestos Containing Materials (RACM) — materials which are friable or may become friable ting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite 350 Centennial, CO 80112 www.atc- enviro.com i 303.799.6100 Fax 303.799.3441 NVLAP Lab Code 102031 PLM REPORT SUMMARY AII-IA Lab Code 101536 Client: Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600111- 931116 Page 12 of 16 Client No. Lab No. Sample Description / Location Asbestos Content 57A 0006842 -059 LAYER 2 None Detected Sheet Flooring Backing, Gray Note: None Detected- Mastic J 2nd Floor, C -203, Kitchen " 57A 0006842 -059 LAYER 3 None Detectcd _.. Sheet Flooring, Orange 2nd Floor, C -203, Kitchen _ LAYER 4 Chrysotile 60% 57A 0006842-059 Sheet Flooring Backing, Gray - Note: Mastic Inscperable 2nd Floor, C -203, Kitchen 58 0006842 - 060 LAYER 1 None Detected J Sheet Flooring, Cream 2nd Floor, C -203, Kitchen 58 0006842 -060 LAYER 2 None Detected Sheet Flooring Backing, Gray Note: None Detected- Mastic �- 2nd Floor, C -203, Kitchen 58 0006842 -060 LAYER 3 None'Detected Sheet Flooring, White 2nd Floor, C -203, Kitchen J These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos f containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) — materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than'ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. Page 13 of 16 Asbestos Content None Detected None Detected None Detected None Detected 58A 0006842 -061 LAYER 4 Chrysotile Sheet Flooring Backing, Gray Note: Mastic Inseperable aY 2nd Floor, C -203, Kitchen 59 0006842 -062 LAYER I None Detected n Sheet Flooring, Multi - colored J J Note: Overall: 30% Chrysotile Ground Floor, D- Hallway, Garden Level t1�i 60% were an by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos These samples w e percent asbestos by Calibrate Area containing only a it contains more than on. d_ Visual A Estimation (CVAE). EPA regulations also indicate that Regulated if Asbestos Containing Materials (RACM) — materials which are liable or may become friable - be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. . The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. W.E. O'Neil Construction company DULU1111V.. ------ Bldg. 52, Denver W. 14062 Deriver W. Pkwy, Ste 240 Report Date: 05103/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/R- 93/116 Client No. Lab No. Sample Description / Location 58 0006842 -060 LAYER 4 Sheet Flooring, Tan. Note: None Detected- Mastic 2nd Floor, C -203, Kitchen 58A 0006842 - 061 LAYER t Sheet Flooring, Cream 2nd Floor, C -203, Kitchen 58A 0006842 - 061 LAYER 2 Sheet Flooring Backing, Gray Note: None Detected - Mastic ` 2nd Floor, C -203, Kitchen LAYER 3 58A 0006842 - 061 J Sheet Flooring, Orange 2nd Floor, C -203, Kitchen Page 13 of 16 Asbestos Content None Detected None Detected None Detected None Detected 58A 0006842 -061 LAYER 4 Chrysotile Sheet Flooring Backing, Gray Note: Mastic Inseperable aY 2nd Floor, C -203, Kitchen 59 0006842 -062 LAYER I None Detected n Sheet Flooring, Multi - colored J J Note: Overall: 30% Chrysotile Ground Floor, D- Hallway, Garden Level t1�i 60% were an by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos These samples w e percent asbestos by Calibrate Area containing only a it contains more than on. d_ Visual A Estimation (CVAE). EPA regulations also indicate that Regulated if Asbestos Containing Materials (RACM) — materials which are liable or may become friable - be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. . The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, Suite . Centennial, CO 80112 www.atc- enviro.com 303.799.6100 Fax 303.7995441 _ Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/11- 93/116 Client No. Lab No. Sample Description / Location NVLAP Lab Code 102031 AIHA Lab Code 101536 Page 14 of 16 Asbestos Content 59 PLM REPORT SUMMARY Chrysotile 65 % - Client: Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.: 0006842 Ground Floor, D- Hallway, Garden Level Bldg. 52, Denver W. 14062 Denver W: Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 804.01 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4 -82 -020; 600/11- 93/116 Client No. Lab No. Sample Description / Location NVLAP Lab Code 102031 AIHA Lab Code 101536 Page 14 of 16 Asbestos Content J These samples were analyzed b la Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos Y Y layers. r containing only if it contains more than one per asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) — materials which are friable or may become friable — be further analyzed by point counting when the results indicate l ' less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. j The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 59 0006842 -062 LAYER 2 Chrysotile 65 % - j� Backing, Gray Ground Floor, D- Hallway, Garden Level t ' ' 60 0006842 - 063 LAYER I Sheet Flooring, Multi- colored None Detected Note: Overall: 30% Chrysotile Ground Floor, D- Hallway, Garden Level 60 0006842 - 063 LAYER 2 Chrysotile 65% Backing, Gray Ground Floor, D- Hallway, Garden Level t 61 0006842 - 064 LAYER 1 None Detected Sheet Flooring, Multi- colored Note: Overall: 30% Chrysotile Ground Floor, D- Hallway, Garden Level 6 Chrysotile 65% 61 0006842 -064 LAYER 2 _ Backing, Gray 3 Ground Floor, D- Hallway, Garden Level ........ 62 0006842 -065 Wall Texture, Wjiite Chrysotile 3 0 / 1 6 Ground Floor, D- Hallway, Garden Level — 63 - - -- -- 0006842 -066 Wall Texture, White - Chrysotile 3% Ground Floor, D- Hallway, Garden Level J These samples were analyzed b la Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos Y Y layers. r containing only if it contains more than one per asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) — materials which are friable or may become friable — be further analyzed by point counting when the results indicate l ' less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. j The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. 8985 E. Nichols Avenue, $uite 350 3 Centennial, CO 80.112 www.atc- enviro com ' 303.799 6100 Fax 303.799.3441 PLM NVLA Lab code 102031 REPORT SUMMARY AIHA L Lab Code 101536 Client: Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O Neil Construction Company Batch No:: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: : N/A Test Method: EPA Method 600IM4 -82 -020; 600/R- 93/116 Page 15 of 16 - Client No. Lab No. Sample Description / Location Asbestos Content 64 0006842 -067 Wall Texture, White Chrysotile 3 I Ground Floor, D- Hallway, Garden Level 65 0006842 -068 Flange Gasket, Green/ Red None Detected Ground Floor, Boiler Room 66 0006842 -069 Flange Gasket, Green/ Red None Detected Ground Floor, Boiler Room 67 0006842 -070 Flange Gasket, Green/ Red _ None Detected r J Ground Floor, Boiler Room f 68 0006842 -071 Splatter Wall Texture, White None Detected Ground Floor, C2- Studio, Hallway 69 0006842 -072 of :. Splatter Wall Texture, White None Detected _ -�- J Ground Floor, C2- Studio, Closet r' 70 0006842 -073 Splatter Wall Texture, White . None Detected Ground Floor; C2- Studio, Closet 71 0006842 -074 Sink Undercoating, Tan Chrysotile 15% ; 2nd Floor, C -203, Kitchen 72 0006842 -075 Sink Undercoating, Tan Chrysotile 15% . 2nd Floor, C -204, Kitchen These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) — materials which are friable or may become friable — be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. may n ^� 8985 E. Nichols Avenue, Suite 350 t/ !' Centennial, CO 80112 www.atc- enviro.com = Uz 303.799.6100 Fax 303.799.3441 PLM REPORT SUMMARY NVLAP Lab code 1 Client: AIHA Lab Code 101536 536 Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.: 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: Test Method: N/A EPA Method 600/M4 -82 -020; 600/R-93/116 Page 16 of 16 Client No. Lab No. Sample Description / Location Asbestos Content 73 0006842 -076 Sink Undercoating, Tan Chrysotile 15% 1 1 3rd Floor, C -302, Kitchen - ..1.1. 74 0006842 -077 Roof Tar, Black Chrysotile 5% ',! ;0!; Roof, Roof Building C 3 4A 75 0006842 - 078 Roof Tar, Black Chrysotile 5 % L Roof, Roof Building C 76 0006842 -079 Roof Tar, Black Chrysotile 5% J Roof, Roof Building C 77 0006842 - 080 LAYER I Chrysotile 5% J Built -up Roof, Black . 1st Floor, Roof Over Studios & Linens 77 0006842 -080 LAYER 2 None Detected Built -up Roof, Black , €. 1st Floor, Roof Over Studios & Linens d r 78 0006842 -081 Built -up Roof, Black None Detected 1st Floor, Roof Over Studios & Linens 79 0006842 -082 Built -up Roof, Black None Detected Ist Floor, Roof Over Studios & Linens J J These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant: The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) — materials which are friable or may become friable — be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Our laboratory utilizes CVAE on a routine basis and does not include point counting unless specifically requested. The results may not be reproduced except in full, and should not be used as a scope of work for abatement without consulting with ATC. i 8985 E. Nichols Avenbe; Suite 35(): Centennial, CO 80112 www.atc-enviro.com 301799.6100 Fax 303.799.3441 -- 11 i 11 1 1 i NVLAP Lab Code 102031 Client: PLM REPORT SUMMARY AIHA I Lab Code 101536 Matthew Hoster ATC Job No.: 35.17693.5296 W.E. O'Neil Construction Company Batch No.• 0006842 Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Report Date: 05/03/2006 Golden CO 80401 Sample Date: 04/27/2006 Project: Asbestos Survey Date Analyzed: 05/03/2006 Client Project No.: Identification: N/A Test Method: EPA Method 600/M4-82-020;600/k-93/ I 16 Paaa I oft PLM Analysis Methodoloe PLM samples were analyzed utilizing the Environmental Protection Agency's Test Method: Method for the Determination of Asbestos in Building Materials (EPA 600/R-93/116. July, 1993), Reporting Limit <1% Asbestos. Additional treatment and tests may be required to accurately define composition (i.e. ashing, extractions, acetone treatment, andTEM). Unused portions of samples are archived for one year unless client reques handling. Asbestos content of mastic/adhesive is separated from total percent asbestos and other materials. Laboratory Equipment Laboratory analysis was accomplished utilizing an Olympus BH-2 polarized light microscope. The microscope is equipped with dispersion staining lenses. Ouality Control A IU Associates, Inc. is accredited by NVLAP Bulk Asbestos Sample Quality Assurance Program (Lab Code 10203 1) and AIHA (Lab Code 10 1536). ATC participates in the NVLAP and AIHA Bulk Asbestos Sample Quality Assurance Programs and maintains an in-house QC/QA program for bulk samples whereby 10% of all submitted samples are reanalyzed and documented in a Quality Control Manual. ATC also participates in a quarterly round robin QC/QA program for bulk samples with several accredited laboratories throughout the United States. Current and past QC/QA program results are available in the laboratory for inspection. Laboratory Personnel -5amptes were anajyzea Dy jerr Lomme, Laboratory Director. Mr. Lomme is a professional geologist who has successfully compf d the McCrone Institutes's "Advanced Asbestos Identification" Course. Approved Signatory: Jeff Lomme NVLAP LAB CODE 102031-0 The non-detection of asbestos fibers in floor tile by PLM is of itself inconclusive. Confirmation by Transmission Electron Microscope (TEM) is recommended for negative floor tile samples. This report must not be used by the client ' to claim product endorsements by NVLAP or an agency of the U.S. government.. This test reports only to the items stated.- BATCH NO. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 101536 Matthew Hoster Client Project No.: W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non - Asbestos Lab ID Sample Location / Constituents Constituents Sample # Sample Description 0006842 -001 3rd Floor, D -313, Storage Closet Chrysotile 2% 1 LAYER 1 Chrysotile: Carbonates 60% Joint Compound, Tan Wavy Fibers Binder/Filler 38% Note: Overall: <1% Chrysotile Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non - pleochroic Q 40X Chrysotile: Para. 1.557 Perp.l.553 None Detected Cellulose Fiber (Incom) 45% — LAYER 2 Gypsum 55% Drywall, White/ Tan — Note: Chrysotile associated with joint compound 0006842 -002 2nd Floor, D -2, Housekeeping Supplies Chrysotile 2% 2 LAYER 1 Chrysotile: Carbonates 65% Joint Compound, Tan Wavy Fibers Binder/Filler 33% Note: Overall: <1% Chrysotile Sign of Elongation ( +) J Parallel Extinction Colorless Birefringence (Low) J Non - pleochroic Q 40X .' Chrysotile: Para. 1.557 . Perp. 1.553 None Detected Cellulose Fiber (Incom) 45% LAYER 2 Gypsum 55% Drywall, White / Tan Note: Chrysotile associated with joint compound .J J � " =i Analyzed by: Reviewed by: /r/f /V(, Page 1 of 20 BATCH NO. 0006842 - NVLAP Lab Code 102031 AIHA Lab Code 101536 Client Project No.: Description: Date Received: Date Analyzed: Date Reported: Comments: Asbestos Constituents Asbestos Survey 05/01/2006 05/03/2006 05/03/2006 Non - Asbestos Constituents Lab ID Sample Location I Sample # Sample Description J Analyzed by: Chrysotile 2% Chrysotile: Carbonates 659/d Wavy Fibers Binder/Filler 33% Sign of Elongation Parallel Extinction Colorless - Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.553 None Detected Cellulose Fiber (Incom) 30% Gypsum 70% Chrysotile- 2% 0006842 -003 1st Floor, D -110, Storage Closet Chrysotile: 3 LAYER 1 Wavy Fibers Binder/Filler Joint Compound, Tan j� Note: Overall: <I% Chrysotile Parallel Extinction Colorless LAYER 2 Birefringence (Low) Drywall, White/ Tan Chrysotile: Para. 1.557 Note: Chrysotile associated with joint None Detected compound 30% Gypsum 0006842 -004 Ground Floor, C- Linens Room 4 LAYER 1 Joint Compound, Tan !� Note: Overall: <1% Chrysotile LAYER 2 Drywall, White/ Tan Note: Chrysotile associated with joint compound J Analyzed by: Chrysotile 2% Chrysotile: Carbonates 659/d Wavy Fibers Binder/Filler 33% Sign of Elongation Parallel Extinction Colorless - Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.553 None Detected Cellulose Fiber (Incom) 30% Gypsum 70% Chrysotile- 2% Chrysotile: Carbonates 65% Wavy Fibers Binder/Filler 33% Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non - pleochroic Q 40X Chrysotile: Para. 1.557 Perp.1.553 None Detected Cellulose Fiber (Incom) 30% Gypsum 70% .. Reviewed by: Page 2 of 20 NO. .. BATCH - 0006842 y. NVLAP d 31 -� AIRA L b C de 101 Matthew Hoster Client Project No.: i W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By Todd Anderson Comments: Collection Address 442 S. Frontage Rd. E. Vail, CO 816 Lab ID Sample Location / Asbestos Constituents Non - Asbestos Constituents E _ Sample # Sample Description 0006842 -005 2nd Floor, C -204, Storage Closet Chrysotile 2% 5 LAYER I Chrysotile: Carbonates Binder/Filler 65% 33% Joint Compound, Tan Wavy Fibers Note: Overall: <I %Chrysotile Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochioic @ 40X Chrysotile: Para. 1.557 Perp.1.553 tttJJJ None Detected Cellulose Fiber (Incom) 35% LAYER 2 Gypsum 65% Drywall, White/ Tan Note: Chrysotile associated with joint compound 0006842 -006 Ground Floor, C -1, Housekeeping Supplies Chrysotile 2% 65% 6 LAYER I Chrysotile: Carbonates Binder/Filler 33% Joint Compound, Tan Wavy Fibers Note: Overall: <1% Chrysotile Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) _ Non- pleochroic @ 40X J Chrysotile; Para. 1.557 Perp.1.553 None Detected Cellulose Fiber (Incom) 40% LAYER 2 Gypsum 60% -' Drywall, White/ Tan Note: Chrysotile associated with joint compound 0006842 -007 Ground Floor, D- Electrical Room None Detected Carbonates 60% 7 LAYER 1 Binder/Filler 40% Joint Compound, Tan None Detected Cellulose Fiber (Incom) 40% LAYER 2 Gypsum 60% Drywall, White/ Tan Note: Chrysotile associated with joint 1 compound BATCH NO. 0006842 NVLAP Lab Code.1 UO31 AM Lab Code 101536 0006842-009 1 s F oor, W.E. O'Neil Construction Company Description: Asbestos Survey Linoleum, White Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Fibrous Glass (ISO) Golden CO 80401 organic Matrix Date Analyzed: 05/03/2006 Linoleum Backing, Gray Collected: 04/27/2006 Date Reported: 05/03/2006 Binder/Filler Collected By: Todd Anderson Comments: J Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Aggregate Binder/Filler Leveling Compound, White Asbestos Non-Asbestos Lab ID Sample Location Constituents Constituents Sample # Sample . Description (%) M 0006842-008 3rd Floor, D-314, Kitchen None Detected Cellulose Fiber (Incom) Fibrous Glass (ISO) organic Matrix 8 LAYER I Linoleum Backing, Gray/ White Now None Detected -Vinyl Surface, Adhesive None Detected Cellulose Fiber (Incom) Fibrous Glass (ISO) Synthetic Fiber (Bic) organic Matrix LAYER Linoleum Backing, Gray/ Cream Note: None Dctccted-Vinyl Surface, Adhesive Chrysotile 60% Cellulose Fiber (Incom) LAYER Chrysotile: Organic Matrix Linoleum Backing, Gray/ Orange Wavy Fibers Note: None Detected-Vinyl Surface Sign of Elongation Parallel Extinction Colorless Birefringence (Low) Non-pleochroic @ 40X Chrysotile: Para. 1.557 Perp. 1.553 I I Bathroom None Detected 0006842-009 1 s F oor, Non-Fibrous Material 9 LAYER I Linoleum, White None Detected Cellulose Fiber (Incom) Fibrous Glass (ISO) organic Matrix LAYER Linoleum Backing, Gray None Detected Binder/Filler LAYER Mastic, Brown None Detected 1 LAYER Aggregate Binder/Filler Leveling Compound, White 35% 15% 50% 15% 60% 25% 15% 100% 35% 15% 50% 100 85% BATCH NO. 00068 i NVLAP Lab Code 102031 AIHA Lab Code 101536 Client Project No.: Matthew Hoster . J W.E. O'Neil Construction Company Description Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 -� Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd..E. Vail, CO 816 Asbestos Non- Asbestos Constituents Lab ID Sample Location / Constituents Sample # Sample Description %) Ground Gd Floor, C2- Studio, Kitchen None Detected Cellulose Fiber (Incom) 35% 0006842 -010 Fibrous Glass (ISO) 15% Organic Matrix 50% 10 LAYER 1 j Linoleum Backing, Gray/ White ' Note: None Detected -Vinyl Surface, Adhesive ))) Chrysotile .60% Cellulose Fiber (Incom) 25% LAYER 2 Chrysotile: Organic Matrix 15 0 - Linoleum Backing, Gray/ Cream Wavy Fibers I Note: None Detected -Vinyl Surface Sign of Elongation ( +) Parallel Extinction Colorless 3 Birefringence (Low) J Non - pleochroic Q 40X Chrysotile: Para. 1.557 Perp.1.552 None Detected Cellulose Fiber (Incom) 45% Fibrous Glass (ISO) 10% Organic Matrix 45% LAYER 3 , Linoleum Backing, Gray/ Brown Note: None Detected -Vinyl Surface, Adhesive Ch sotile 5% Cellulose Fiber (Incom) 3% 0006842 -011 2nd Floor, D-207, Living Room n Wavy Fibers 60% Chrysotile: Carbonates I 1 Acoustical Ceiling Texture, White ry Binder/Filler 32 % r , J Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic (a3 40X Chrysotile: . Para. 1.556 Perp.1.549 2nd Floor, D -212, Living Room Chrysotile 5 % 0006842 -012 Carbonates 65% Acoustical Ceiling Texture, White . Chrysotile: 30% 12 Wavy Fibers Binder/Filler Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic ® 40X Chrysotile: Para. 1.556 Perp.1.549 1 J / Page 5 of 20 Analyzed by: _ Reviewed by: ✓y/ BATCH NO. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 101536 Client Project No.: Matthew Hoster. J W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006. Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non - Asbestos Lab ID Sample Location"/ Constituents Constituents Sample # Sample Description Chrysotile 8% Cellulose Fiber (Incom) 2% J 0006842 -013 1st Floor, D -112, Bedroom ry Carbonates 60% 13 Acoustical Ceiling Texture, White Chrysotile: Wavy Fibers Binder/Filler 30% Sign of Elongation ( +) Parallel Extinction U Colorless Birefringence (Low) Non- pleochroic Q 40X Chrysotile: Para. 1.556 Perp.1.549 Cellulose Fiber (incom) 2% 0006842 -014 Ground Floor, D- Hallway, Garden Level Chrysotile 5% Fibrous Glass (ISO) 3% `j Carbonates 60% J 14 Acoustical Ceiling Texture, White Chrysotile: Wavy Fibers Binder[Filler 30% .Sign of Elongation ( +) Parallel Extinction 1 Colorless J Birefringence (Low) Non- pleochroic (a3 40X Chrysotile: Para. 1.556 Perp.1.549 - I st Floor, C -102, Livin Room Chrysotile 5 % 0006842 -015 l g Carbonates Chrysotile: 70% 15 Acoustical Ceiling Texture, White Binder/Filler 25% J Wavy Fibers Sign of Elongation ( +) Parallel Extinction Colorless ' Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.556 Perp.1.549 2nd Floor, C -203, Bedroom Chrysotile 5 % 0006842 -016 Chrysotile: Carbonates 70% 16 Acoustical Ceiling Texture, White Wavy Fibers Binder/Filler 25 %' Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic cQ 40X Chrysotile: Para. 1.556 Perp.1.549 Page 6 of 20 Analyzed by: Reviewed by: t' ff BATCH NO.' .. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 10I536 Client Project No.: Description: Date Received: Date Analyzed: Date Reported: Comments: Asbestos Survey 05/01/2006 05/03/2006 05/03/2006 Asbestos Non- Asbestos Lab ID Sample Location / Constituents Constituents � Sample # Sample Description 0006842 -017 2nd Floor, C -201, Living Room Chrysotile 5% Cellulose Fiber (Incom) <I% 17 Acoustical Ceiling Texture, White Chrysotile: Carbonates 60% Wavy Fibers Binder[Filler 34% Sign of Elongation ( +) I 1 Parallel Extinction i J Colorless Birefringence (Low) ; Non- pleochroic @ 40X ;It; rs ' Chrysotile: Para..1.556 Perp. 1.549 0006842 -018 Ground Floor, C- Laundry Room None Detected Cellulose Fiber (Incom) 30% Fibrous Glass (ISO) 40% 1 g 2'x4' Ceiling Tile, White, Fiss. Organic Matrix 15% i_ Perlite 15% i 0006842 -019 Cellulose Fiber Incom 30% . Ground Floor, C- Laundry Room None Detected ( Incom) J Fibrous Glass (ISO) 40% 19 2'x4' Ceiling Tile, White, Fiss, Organic Matrix 15% Perlite 15% 0006842 -020 Ground Floor, C2- Studio (Living Area) None Detected Cellulose Fiber (Incom) 30% Fibrous Glass (ISO) 40% 20 2'x4' Ceiling Tile, White, Fiss. Organic Matrix 15% J Perlite 15% 0006842 -021 3rd Floor, D -314, Kitchen Chrysotile 5% 'Cellulose Fiber (Incom) 2% ° 21 'K' Sink Under Coating, Black Chrysotile Aggregate 20 /° Wavy Fibers Tar Binder 73% Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.556 Perp.1.550 J Analyzed by: Reviewed by: Page 7 of 20 J . 3 1 Matthew Hoster W.E. O'Neil Construction Company Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Golden CO 80401 Collected: 04/27/2006 Collected By: Todd Anderson 4 J Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Lab ID Sample Location / Sample # Sample Description 0006842 -022 2nd Floor, D -208, Kitchen 22 Sink Under Coating, Black J I iJ 0006842 -023 1st Floor, D -110, Kitchen 23 Sink Under Coating, Black i 0006842 -024 3rd Floor, D -314, Kitchen 24 Cove Base Adhesive, Brown _. Client Project No.: 0006842 -025 Description: Asbestos Survey Date Received: 05/01/2006 Date Analyzed: 05/03/2006 Date Reported: 05/03/2006 Comments: 5% BATCH NO. 0006842 NVLAP Lab Code 102031 AIRA Lab Code 101536 Asbestos Non - Asbestos Constituents Constituents %°) M. Chrysotile 5% 0006842 -025 Chrysotile: Aggregate Wavy Fibers Tar Binder Sign of Elongation ( +) Parallel Extinction.,_ Colorless 5% Birefringence (Low) 25 Non - pleochroic @ 40X Chrysotile; Para. 1.556 Perp.1.550 Chrysotile 5% 0006842 -026 Chrysotile: Aggregate Wavy Fibers Tar Binder Sign of Elongation ( +) Parallel Extinction Colorless 5% Birefringence (Low) 26 Non - pleochroic @ 40X Chrysotile: Para. 1.556 Perp.1.550 None Detected Cellulose Fiber (Incom) Ground Floor, C- Boiler Room Aggregate Cellulose Fiber (Incom) Binder/Filler 20% 75% 20% 75% 5% 15% 80% 0006842 -025 Ist Floor, D -110, Bathroom None Detected Talc (Morph) 10% - Cellulose Fiber (InCDM) 5% 25 Cove Base Adhesive, Brown Binder/Filler 85% 0006842 -026 Ground Floor, C1- Studio Bathroom None Detected Talc (Morph) 10% Cellulose Fiber (Incom) 5% 26 Cove Base Adhesive, Brown Binder/Filler 85% 0006842 -027 Ground Floor, C- Boiler Room None Detected Cellulose Fiber (Incom) 2% Fibrous Glass (ISO) 15% l Wollastonite (Morph) 10% J 27 Pipe Insulation Sealant, White Binder/Filler 73% 0006842 -028 Ground Floor, C- Boiler Room None Detected Cellulose Fiber (Incom) 5% Fibrous Glass (ISO) 15% Wollastonite (Morph) 15% ' 28 Pipe Insulation Sealant, White Binder/Filler 65% J Analyzed by: Reviewed by: Page 8 of 20 BATCH NO. 0006842 NVLAP Lab Code 1020 1 AIHA Lab Code 101536' Matthew Hoster Client Project No.: W.E. O'Neil Construction Company Description Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 j Asbestos Non - Asbestos Lab ID Sample Location / Constituents Constituents Sample # Sample Description ( %) M 0006842 -029 Ground Floor, C- Boiler Room None Detected Cellulose Fiber (Incom) 5% Fibrous Glass (ISO) 15% Wollastonite (Morph) 15% 29 Pipe Insulation Sealant, White Binder/Filler 65% 0006842 -030 3rd Floor, D- Breezeway Near 307 None Detected 30 Stucco, White / Gray Aggregate 60 %:.! Binder/Filler 40 %°tisi 0006842 -031 1/2 Floor, D- Breezeway None Detected 31 Stucco, White/ Gray Aggregate 60% Binder/Filler 40% M06842 -032 Ist Floor, D -110, Balcony None Detected 32 Stucco, White/ Gray Aggregate Binder/Filler 60% 40% 0006842 -033 Ground/ Ist Floor, C- Breezeway None Detected 33 Stucco, White/ Gray Aggregate 60% Binder/Filler 40% 1 0006842 -034 Ground Floor, C- Exterior (South Wall) None Detected 34 Stucco, White/ Gray Aggregate 60% ;Binder/Filler 40% 0006842 -035 2nd Floor, C -203 Balcony None Detected 35 Stucco, White/ Gray Aggregate 60% Binder/Filler 40% 0006842 -036 3rd Floor, C- Breezeway Near 301 None Detected JJJ 36 Stucco, White / Gray Aggregate 60 % Binder/Filler 40 0006842 -037 Ground Floor, C -South Exterior Wall None Detected Cellulose Fiber (Incom) 5% 37 Sealant, Green/ Red Binder/Filler 95% 0006842 -038 Ground Floor, C -South Exterior Wall None Detected Cellulose Fiber (Incom) 5% 38 Sealant, Green/ Red Binder/Filler 95% . Analyzed b a yzed y — Reviewed by: �, , Page 9 of 20 BATCH NO. 0006842 _ NVLAP Lab Code 102031 AIHA Lab Code 101536 Matthew HOSter Client Project No.: W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: ' Collection Address: 442 S, Frontage Rd. E. Vail, CO 816 _ Asbestos Non- Asbestos Lab ID Sample Location / Constituents Constituents Sample # Sample Description M) %) V ` 0006842 -039 Ground Floor, C -South Exterior Wall None Detected Cellulose Fiber (Incom) 5 % 39 Sealant, Green/ Red Binder/Filler 95% Cellulose Fiber Incom 5% 0006842 -040 Roof, Roof Building C None Detected ( ) Fibrous Glass (ISO) 15 %° 40 Roofing Material, Black/ Brown/ White Aggregate 15% Tar Binder 65% • — — Cellulose Fiber (Incom 5% 0006842 -041 Roof, Roof Building C None Detected ) o Fibrous Glass (ISO) 15 /0 ° 41 Roofing Material, Black/ Brown/ White Aggregate 15% Tar Binder 65% Q006842 -042 Roof, Roof Building C None Detected Cellulose Fiber (Incom) 5% Fibrous Glass (ISO) 15 %° 42 Roofing Material, Black/ Brown/ White Aggregate 15% Tar Binder „ 65% Incom 0006842 -043 3rd Floor, D- Breezeway Near 307 None Detected Cellulose Fiber ( ) . <1% Fibrous Glass (ISO)` 4 Synthetic Fiber (Bie) 10% 43 Carpet Mastic, Tan Binder/Filler 84% Cellulose Fiber Incom 5% . 0006842 -044 1 s Floor, D -110, Carpet on Balcony None Detected ( ) ;Fibrous Glass (ISO) <1% Synthetic Fiber (Bie) 10% 44 Carpet Mastic, Tan Binder/Filler 84% 0006842 -045 Ground Floor, C -Garden Level Balcony None Detected Cellulose Fiber (Incom) 5% Synthetic Fiber (Bie) 10% 45 Carpet Mastic, Tan Binder/Filler 85% 0006842 -046 3rd Floor, D -314 Hallway Chrysotile 3 °/, Cellulose Fiber (Incom) 2% 46 Wall Texture, White Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35% Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic (a3 40X Chrysotile: Para. 1.557 Perp.1.552 'age 10 of 20 Analyzed by: Reviewed by: BATCH NO. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 101536 Matthew Hoster Client Project No.: W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 _ Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non - Asbestos Lab ID Sample Location / Constituents Constituents Sample # Sample Description ( %) ( %) J 0006842 -047 2nd Floor, D -210, Living Room Chrysotile 5% 47 Wall Texture, White Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35% Sign of Elongation ( +) Parallel Extinction, Colorless Birefringence (Low) Non - pleochroic @ 40X Chrysotile`. Para. 1.557 Perp.1.552 0006842 -048 1st Floor, C -102, Kitchen Chrysotile 5% 48 Wall Texture, White Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35% Sign of Elongation (+) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic @ 40X 11 Chrysotile: Para. 1.557 Perp.1.552 J 0006842 -049 2nd Floor, C -203, Living Room Chrysotile 2% Cellulose Fiber (Incom) 3% 49 Wall Texture, White Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35% Sign of Elongation ( +) Parallel Extinction Colorless ' _ Birefringence (Low) =x Non- pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.552 0006842 -050 2nd Floor, C -204, Hallway Chrysotile $% 50 Wall Texture, White Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35% Sign of Elongation ( +) Parallel Extinction J Colorless Birefringence (Low) Non = pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.552 . Analyzed by b Sage 11 of 20 : Reviewed y /�!, Matthew Koster W.E. O'Neil Construction Company Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Golden CO 80401 Collected: 04/27/2006 Collected By: Todd Anderson Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Lab ID Sample Location / Sample # Sample Description 0006842 -051 3rd Floor, C -302, Closet 51 Wall Texture, White , t Asbestos Non- Asbestos Constituents Constituents Chrysotile 5% Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35 %" Sign of Elongation ( +) Parallel Extinction . Colorless Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.552 0006842 -052 BATCH NO. i 52 0006842.: , `J Binder/Filler NVLAP Lab Code 10203.1 J ATHA Lab Code 101536 Client Project No.: _ 3rd Floor, D -314, Bathroom Description Asbestos Survey J 0006842 Date Received: 05/01/2006 -054 Date Analyzed: 05/03/2006 54 Date Reported 05/03/2006 Comments: 0006842 -055 2nd Floor, C -204, Bathroom Asbestos Non- Asbestos Constituents Constituents Chrysotile 5% Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35 %" Sign of Elongation ( +) Parallel Extinction . Colorless Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.552 Chrysotile 5% 0006842 -052 3rd Floor, C -306, Bedroom i 52 Wall Texture, White `J Binder/Filler 35% J 0006842 -053 _ 3rd Floor, D -314, Bathroom 53 Ceramic Tile Adhesive, Tan J 0006842 Birefringence (Low) -054 2nd Floor, D -213, Bathroom 54 Ceramic Tile Adhesive,'Tan Perp.1.552 None Detected 0006842 -055 2nd Floor, C -204, Bathroom 55 Ceramic Tile Adhesive, Tan Chrysotile 5% Chrysotile: Carbonates 60% Wavy Fibers Binder/Filler 35% Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non - pleochroic Q 40X Chrysotile: Para. 1.557 Perp.1.552 None Detected Binder/Filler 100% None Detected ;Binder/Filler 100% None Detected Binder/Filler 100% Analyzed by: J Reviewed by: ,��� 'age 12'tif 20 ! `J *1 J Collection Matthew Hoster W.E. O'Neil Construction Company Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Golden CO 80401 Collected: 04/27/2006 Collected By: Todd Anderson Address 442 S. Frontage Rd. E. Vail, CO 816 Client Project No.: Description: Date Received Date Analyzed: Date Reported: Comments: BATCH NO. 0006842 NVLAP Lab Code 102031 AIRA Lab Code 101536 Asbestos Survey 05/01/2006 05/03/2006 05/03/2006 Asbestos Non-Asbestos. Lab ID Sample Location / Constituents Constituents Sample Description ( %) Sample # 0006842 - 056 2nd Floor, C -203, Kitchen None Detected Non - Fibrous Material 100% 56. LAYER 1 Sheet Flooring, Cream None Detected Cellulose Fiber (Incom) 30% Fibrous Glass (ISO) 15% Organic Matrix 55% LAYER 2 Sheet Flooring Backing, Gray Note: None Detected - Mastic None Detected Non - Fibrous Material 100% LAYER 3 Sheet Flooring, White None Detected Cellulose Fiber (Incom) 25% Fibrous Glass (ISO) 15% Organic Matrix 60% LAYER 4 Sheet Flooring, Tan Note: None Detected - Mastic rrr���JJJ 1 0006842 -057 2nd Floor, C -203, Kitchen None Detected Non - Fibrous Material 100% J 56A LAYER 1 Sheet Flooring, Cream None Detected Cellulose Fiber (Incom) 20% ' �- Fibrous Glass (ISO) 15% J Synthetic Fiber (Bie) 15% Organic Matrix 50% LAYER 2 ., Sheet Flooring Backing, Gray Note: None Detected- Mastic None Detected Non- Fibrous Material 100% LAYER 3 Sheet Flooring, Orange Chrysotile 60% Cellulose Fiber (Incom) 20 % ' LAYER 4 Chrysotile: Organic Matrix 20% l Sheet Flooring Backing, Gray Wavy Fibers J Note: Mastic Inseperable Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) l Non- pleochroic Q 40X s Chrysotile: Para. 1.555 Perp.1.549 Reviewed by: . 13 of 20 Analyzed by: _ j BATCH NO. 0006842 . NVLAP Lab Code 102031 AIHA Lab Code 101536 Matthew Hoster Client Project No.: W.E.' O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non- Asbestos Lab ID Sample Location / Constituents Constituents Sample # Sample Description ( %) M 0006842 -058 2nd Floor, C -203, Kitchen None Detected 57 LAYER 1 Non- Fibrous Material 100% Sheet Flooring, Cream None Detected Cellulose Fiber (Incom) 30 0 /6 Fibrous Glass (ISO) 15% LAYER 2 Organic Matrix 55% Sheet Flooring Backing, Gray J Note: None Detected - Mastic None Detected LAYER 3 Non- Fibrous Material 100% Sheet.Flooring, White None Detected Cellulose Fiber (Incom) 25% Fibrous Glass (ISO) 15% LAYER 4 Organic Matrix 60% Sheet Flooring, Tan Note: None Detected - Mastic 0006842 -059 2nd Floor, C -203, Kitchen None Detected 57p GAYER I Non - Fibrous Material 100% Sheet Flooring, Cream l None Detected Cellulose Fiber (Incom) 20% J t Fibrous Glass (ISO) 15% ;Synthetic Fiber (Bie) 15% _ K LAYER 2 . Organic Matrix 50% , Sheet Flooring Backing, Gray Note: None Detected- Mastic None Detected LAYER 3 Non- Fibrous Material 100% Sheet Flooring, Orange Chrysotile 60% Cellulose Fiber (Incom) 20% LAYER 4 Chrysotile: Organic Matrix 20% l Sheet Flooring Backing, Gray Wavy Fibers J Note: Mastic Inseperable Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic Q 40X Chrysotile: Para. 1.555 Perp.1.549 Reviewed b 'age 14 of 20 Analyzed by: Y BATCH NO. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 101536 Matthew Hoster 0006842 -061 Client Project No.: Asbestos W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 ( %) Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 r 1 LAYER 2 Sheet Flooring Backing, Gray Note: None Detected - Mastic None Detected LAYER3 Sheet Flooring, White None Detected - LAYER 4 Sheet Flooring, Tan Note: None Detected- Mastic 1 0006842 -061 2nd Floor, C -203, Kitchen None Detected Asbestos 58A LAYER l Lab ID Sample Location / Constituents Detected Sample # Sample Description ( %) Sheet Flooring Backing, Gray 0006842 -060 2nd Floor, C -203, Kitchen None Detected None Detected 58 LAYER 1 Sheet Flooring, Cream r 1 None Detected LAYER 2 Sheet Flooring Backing, Gray Note: None Detected - Mastic None Detected LAYER3 Sheet Flooring, White None Detected - LAYER 4 Sheet Flooring, Tan Note: None Detected- Mastic 1 0006842 -061 2nd Floor, C -203, Kitchen None Detected 30% 58A LAYER l Organic Matrix Sheet Flooring, Cream J None Detected LAYER 2 Sheet Flooring Backing, Gray Note: None Detected- Mastic ` J None Detected Non - Asbestos Constituents Non - Fibrous Material 100% Cellulose Fiber (Incom) 30% Fibrous Glass (ISO) 15 Organic Matrix 55% Non - Fibrous Material 100% Cellulose Fiber (Incom) 25% Fibrous Glass (ISO) 15 %.. Organic Matrix 60% Non - Fibrous Material 100% Cellulose Fiber (Incom) Fibrous Glass (ISO) ,Synthetic Fiber (Bie) Organic Matrix LAYER 3 Non- Fibrous Material Sheet Flooring, Orange Chrysotile 60% Cellulose Fiber (Incom) LAYER 4 Chrysotile: Organic Matrix Sheet Flooring Backing, Gray Wavy Fibers Note: Mastic Inseperable Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non- pleochroic Q 40X Chrysotile: Para. 1.555 Perp.1.549 20% 15% 15 % 50% 100% 20% 20% Analyzed by: Reviewed by: �jv� A/ 'age 15 of 20 BATCH NO. .. 0006842:; NVLAP Lab Code. 102031 AIHA Lab Code 107536' :; Matthew Hoster Client Project No.: W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported 05/03/2006 1 Collected By: Todd Anderson Comments: J Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non - Asbestos - Lab ID Sample Location / Constituents Constituents Sample # Sample Description ( %) ( %) 0006842 -062 Ground Floor, D- Hallway, Garden Level None Detected �.J 59 LAYER 1 Non- Fibrous Material 100 %. Sheet Flooring, Multi- colored Note: Overall: 30% Chrysotile L Chrysotile 65 %6 Cellulose Fiber (Incom) 25 LAYER 2 Chrysotile: Organic Matrix 10% Backing, Gray Wavy Fibers i� : air• Sign of Elongation ( +) LJ Parallel Extinction Colorless " Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.550 - 0006842 -063 Ground Floor, D- Hallway, Garden Level None Detected 60 LAYER 1 Non - Fibrous Material 100% Sheet Flooring, Multi- colored Note: Overall: 30% Chrysotile 1 Chrysotile 65% Cellulose Fiber (Incom) 25% J LAYER 2 Chrysotile: Organic Matrix 10% Backing, Gray Wavy Fibers Sign of Elongation ( +) Parallel Extinction Colorless " Birefringence (Low) ; Non -pleochroic ar 40X Chrysotile:_ , Para. 1.557 Perp. 1.550 - -- 0006842 -064 ` - -- -- —_ -- Ground Floor, C- Boiler Room, Garden Level _ None Detected 61 LAYER 1 Non- Fibrous Material 100% . Sheet Flooring, Multi- colored Note: Overall: 30% Chrysotile Chrysotile 65% Cellulose Fiber (Incom) 25% 1 LAYER 2 Chrysotile: Organic Matrix 10 % J Backing, Gray Wavy Fibers Sign of Elongation ( +) Parallel Extinction Colorless . Birefringence (Low) Non- pleochroic @ 40X Chrysotile: Para. 1.557 Perp.1.550 Analyzed : b y Y Reviewed by 'age 16 of 20 BATCH NO. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 101536 iJ - Client Project No.: Matthew Hoster W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Date Reported: 05/03/2006 Collected: 04/27/2006 Collected By Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 As Non - Asbestos Constituents Constituents Lab ID Sample Location / Sample # Sample Description %) 0006842 -065 Ground Floor, D- Hallway, Garden Level Chrysotile Carbonates 60% Binder/Filler Wall Texture, White Chrysotile: 37% 62 Wavy Fibers Sign of.Elongation ( +) Parallel Extinction Colorless Birefringence (Low) " Non- pleochroic @ 40X Chrysotile: Para. 1.556 Perp.1.547 3% 0006842 -066 Ground Floor, D- Hallway, Garden Level Chrysotile Carbonates 60% Wall Texture, White Chrysotile: Binder/Filler 37% 63 Wavy Fibers Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) Non - pteochroic @ 40X Chrysotile: Para. 1.556 Perp.1.547 0.006842 -067 Ground Floor, D- Hallway, Garden Level Chrysotile Carbonates 60% Binder/Filler Wall Texture, White Chrysotile: 37% 64 Wavy Fibers Sign of Elongation ( +) l Parallel Extinction Colorless Birefringence (Low) Non- pleochroic @ 40X Chrysotile: Para. 1.556 Perp.1.547 Ground Floor, Boiler Room None Detected Wollastonite (Morph) 20% 0006842 -068 Binder/Filter 80% 65 Flange Gasket, Green/ Red Ground Floor, Boiler Room None Detected Wollastonite (Morph) 20% 0006842 -069 Binder/Filler 80% 66 Flange Gasket, Green/ Red Ground Floor, Boiler Room None Detected Wollastonite (Morph) 20% 0006842 - 070 Binder/Filler 80% 67 Flange Gasket, Green/ Red �� Reviewed by: gage 17 of 20 v �/( Analyzed by: BATCH NO. , 13 , ,r 2f. 0006842 NVLAP Lab Code 102031 AIHA Lab Code 101536 . 1 Matthew Hosier Client Project No.: - W.E. O'Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non- Asbestos I If Lab ID Sample Location/ Constituents Constituents Sample # Sample Description ( %) 0006842 -071 Ground Floor, C2- Studio, Hallway None Detected 68 Splatter Wall Texture, White Carbonates 65% Binder/Filler 35% 0006842 -072 Ground Floor, C2- Studio, Closet None Detected Carbonates 65% 69 Splatter Wall Texture, White Binder/Filler 35 %�' 1 ` - "'• � 0006842 -073 Ground Floor, CI- Studio, Closet None Detected 70 Splatter Wall Texture, White Carbonates 65% Binder/Filler 35% 0006842 -074 2nd Floor, C -203, Kitchen Chrysotile IS% 7 Sink Undercoating, Tan Chrysotile: Vermiculite 10% Wavy Fibers Carbonates 60% Sign of Elongation ( +) Binder/Filler 15% Parallel Extinction Colorless, r Birefringence (Low) 1 Non - pleochroic (a3 40X Chrysotile: Para. 1.555 Perp.1.549 J 0006842 -075 2nd Floor, C -204, Kitchen Chrysotile 15% r Chrysotile: Vermiculite 10% 72 Sink Undercoating, Tan ry Carbonates 60% Wavy Fibers Sign of Elongation (+) Binder/Filler 15% Parallel Extinction Colorless Birefringence (Low) Non - pleochroic @ 40X Chrysotile: Para. 1.555 Perp.1.549 0006842 -076 3rd Floor, C. -302, Kitchen Chrysotile 15% 73 Sink Undercoating, Tan Chrysotile: Vermiculite 10 %, Wavy Fibers Carbonates 60% J Sign of Elongation ( +) Binder/Filler 15% Parallel Extinction Colorless Birefringence (Low) Non - pleochroic (a3 40X Chry sotile: Para. 1.555 Perp.1.549 _ - -- — — Reviewed by: gage 18 61 20 Analyzed by: J BATCH.NO 0006842 NVLAP Lab Code ik ' i J AIRA Lab Code 1W.W -„ Matthew Hoster Client Project No.: W.E. O`Neil Construction Company Description: Asbestos Survey Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: 05/01/2006 Golden CO 80401 Date Analyzed: 05/03/2006 Collected: 04/27/2006 Date Reported: 05/03/2006 Collected By: Todd Anderson_ Comments: Collection Address: 442 S. Frontage Rd. E. Vail, CO 816 Asbestos Non - Asbestos Lab ID Sample Location / Constituents Constituents J Sample # Sample Description 0006842 -077 Roof, Roof Building C Chry sotile 5% Cellulose Fiber (Incom) 25% 74 Roof Tar, Black Chrysotile: Aggregate Tar Binder 25% 45% Wavy Fibers Sign of Elongation ( +) Parallel Extinction Colorless _ Birefringence (Low) : ' r .. I Non= pleochroic @ 40X Chrysotile: Para. 1.552 Perp. 1.548 . : 0006842 -078 Roof, Roof Building C Chrysotile 5% Cellulose Fiber (Incom) 25% 75 Roof Tar, Black Chrysotile: Wavy Fibers Aggregate Tar Binder 25%. 45% J Sign of Elongation ( +) Parallel Extinction Colorless Birefringence (Low) `J Non- pleochroic Q 40X Chrysotile: Para. 1.552 Perp.1.548 J 0006842 -079 Roof, Roof Building C Chrysotile 5% Cellulose Fiber (Incom) 25% 76 Roof Tar, Black Chrysotile: Aggregate Tar Binder 25% 45% Wavy Fibers 7 Sign of Elongation ( +) J Parallel Extinction Colorless Birefringence (Low) ' Non - pleochroic Q 40X Chrysotile: Para. 1.552 Perp.1.548 • 5 e 1 Reviewed by: 2 age 19 of 20. J Anal zed b y y _. Asbestos Constituents. Non- Asbestos Constituents r -� 0006842 -080 1st Floor, Roof Over Studios & Linens 77 LAYER 1 Built -up Roof, Black J LAYER 2 Built -up Roof, Black Chrysotile 5% Cellulose Fiber (Incom) BATCH NO. Chrysotile: Aggregate 0006842 Wavy Fibers Tar Binder NVLAP Lab Code 102031 :. Sign of Elongation ( +) Matthew Hoster, AIHA Lab Code 101536 Client Project No.: W.E. O'Neil Construction Company Description Bldg. 52, Denver W. 14062 Denver W. Pkwy, Ste 240 Date Received: Golden CO 80401 ,. L Collected: 04/27/2006 Date Reported: Collected By: Collection Address Todd Anderson 442 S. Frontage Rd. E. Vail, CO 816 None Detected Cellulose Fiber (Incom) 20% Comments: Lab ID Sample Location / Aggregate Sample # Sample Description Asbestos Constituents. Non- Asbestos Constituents r -� 0006842 -080 1st Floor, Roof Over Studios & Linens 77 LAYER 1 Built -up Roof, Black J LAYER 2 Built -up Roof, Black Chrysotile 5% Cellulose Fiber (Incom) BATCH NO. Chrysotile: Aggregate 0006842 Wavy Fibers Tar Binder NVLAP Lab Code 102031 :. Sign of Elongation ( +) Fibrous Glass (ISO) AIHA Lab Code 101536 Client Project No.: 10% Tar Binder Description Asbestos Survey Date Received: 05/01/2006 ,. Date Analyzed: 05/03/2006 Date Reported: 05/03/2006 None Detected Cellulose Fiber (Incom) 20% Comments: Fibrous Glass (ISO) 5% - . -° . Asbestos Constituents. Non- Asbestos Constituents r -� 0006842 -080 1st Floor, Roof Over Studios & Linens 77 LAYER 1 Built -up Roof, Black J LAYER 2 Built -up Roof, Black Chrysotile 5% Cellulose Fiber (Incom) 20% Chrysotile: Aggregate 10% Wavy Fibers Tar Binder 65% Sign of Elongation ( +) Fibrous Glass (ISO) 5% ' Parallel Extinction 10% Tar Binder Colorless ; Birefringence (Low) ,. Non- pleochroic @ 40X Chrysotile: Para. 1.552 Perp.1.548 None Detected Cellulose Fiber (Incom) 20% Fibrous Glass (ISO) 5% - . -° . Aggregate 20% Tar Binder 55% 0006842 -081 1st Floor, Roof Over Studios & Linens L ] 78 Built -up Roof, Black J 0006842 -082 1st Floor, Roof Over Studios & Linens J 79 Built -up Roof, Black J J Analyzed by: J None Detected Cellulose Fiber (Incom) 20 Fibrous Glass (ISO) 5% Aggregate 10% . Tar Binder 65 % ;. None Detected Cellulose Fiber (Incom) 20 % Fibrous Glass (ISO) 5% ' Aggregate 10% Tar Binder 65% Reviewed by: ' age 20 of .20 Company W, C 0 "A) s I r G I' C Name: Xs u Address: s c C-IL — W Collection Date: - 27 -2dO(- Ob Z lew�e - We f Pk. P.O./Client Number: /76 Phone/ ax: 303= yt'o 2, - Z /Z Analysis: 2 hr. 24 Hr. -5 Client Contact: Mr. /tl b P Collection Address: VVZ - n.1 s .ce z Ko 1/4; /, Co .914e s7 - SEGfS Gc o lct G� C D $D K O I L s A Notes: SAMPLE DATA ; J _J j 6rO A 6%, 60b l Relinquished by Sampler: Date/Time Received by: Date/Time J Relinquished by Sampler DatefTime Received by: Date/Time J . Sample collector is responsible for ensuringthat all samples have been preserved and prepared to the appropriate and applicable methodology. If package has sustained damage during transit, notify collector and shipper. Turnaround time begins upon receipt of sample (s) by laboratory. ATC will not be responsible for errors or omissions in calculations form in accuracy of orijinal data. U O J V ` Al Z F- _ W O a Ir Q W ui 1 to Q J� W' y H An z us "0 V I O 3 m v F � G F U O J V ` Al Z F- _ W O a Ir Q W ui 1 to Q J� W' e N x t r 0 w U w a z w F- Q 0 i I m 0 w H U w CL cn z C 0 0 G a E G W y H An z us "0 V I 3 v F � G M a z M " L W b V S p J W J O t Q U N H . O z : K W U a ° N ti ` N �C z O 4O U a. a fIn I V 'u W . Z o. M 3 L rr z o :- LU VA v LU Q U J V1 U a Q W W f" Q d c i y e N x t r 0 w U w a z w F- Q 0 i I m 0 w H U w CL cn z C 0 0 G a E G W C .J ' I t J r i F . L a CL l Q W W C Q Q J W 3 3 0 0 i O tl '- . ^ O W � ' tl X D O Q ■ w r U w CL U) Z w F- Q O m w t- U w a z J 0 w c E c W I I 0 CC Ul LU LU Cc ui L) ui CL U) z LU F— C, 0 AoZS al o LLJ F— ui cn z O Lu .. -j ui CL IN a cc L 4 LU IL Ul L� { N 0 uj J m T F z �d U W U N :.. - u o -,j N O h Z Z 6 W x Z � O U � w o IL t z o. V d - G ai U H � v W W_ X39 Q cc ul Z O n � IL N N tea J w . .. [ W La _ N LU Z T. .F d d W 0 v �l U N P ~ s r , \ , y �1 J J . W J ac N W 1-� O Z ui U 3 0 3 C M v � o a z 0 W u a . N IL 4 Q ¢ o Cc W i u r vj V LL W a o' N M U A V 04 cc us �� N D < Q J J y .' Q O W CL W J F ` N N : V N 7 e V � M O W U w CL U Z w a 0 c . 0 E c C W e l F- W V 3 m z j �l o � z v ° v IF N t O U N J L ". F N_ g W '„ LL 0 z Ix .'M x U N a l � J z Q a L vl N W N =1 H W ? o C� v! � a z� _ o ,< W' f S W W v o " _w" e N v O w U w CL U) Z w Q D 3 0 \ 0 s N 3 0 • i u .2 . I . �4 C LL U CL Q N r 0 w U w CL N z 0 . 0 a s c . W s 0 0 c U 'N LU . � 0 J C7 l r z a z O v. p ' �i c a 0 U h O C _ a W 2 lu - U � W O a o M � fj o � � a Q Q CL W v y .N W p � W d 00 z° l 0 �V a Z� d < Z: n L) W :. _ a ui ° J J N J LJ.1 cc F a _ I s 0 0 c U <� t J m t� 4 O J e Y C Z . U _ w `J O J � a y N Q W uj J � _ � C �.: 2 d Q Q V W Q ic � J W W S e z W - C s Q Q nM La 1Vl O p V tig U. W N W 0. O F z W m / 3 0 0 • s / 0 <a CL C.) W \ t M � N � o / 'V or U. =S N a s. U U z O - d . , / • Z z U ul IL 1, O < VI U O W J < N r v 0 e M x ❑ W F— U W a. z LL) F— Q ❑ r m w F— U W a. cn z c 0 w w C O c 0 c W �v ° 5 m x G S U � O � LJ h z ..•JM z z U W 0 O It CL t Q r v ' W J � a =� 1 o 0 J J I W Lu g milli Olson COMMON » z v N 0 LLJ U w a _z w Q D j- M D W F-- U W CL U) z M 0 'y C W Ila. C C J O L-1 v V' L � U W O cc IL ui N Q W C/) a I .J W_ N N- o O _O U w F F- U z w Q a U) z . w z F- v a 0 _N 5 I j O.O \J V w 3 W cc W , N O z "yr ' 3 3 0 o. v U C 0 m Ic W CL Z° v z o 9� a z O Q W: m j V f..CL o a: S Q ll� L N ,i c 0 0 E W mill tD « x v N ` 0 w U w a_ V) Z w H Q ❑ m w H U w a Z C a .« S 0 0 E 0 . W H f Z LLI � ciJ m v r � c v U 1 f ; LU • N ' V �J U ` O J 1 us O � =J M i • C-12 1 , . 0 Z ku d a z W V _ us W o a Zg LL t� J � W Co 0 w IL M J p ° `� fA J � LU W _ mill tD « x v N ` 0 w U w a_ V) Z w H Q ❑ m w H U w a Z C a .« S 0 0 E 0 . W d! CO); e ' O V C7 m > w U ! 1 j i z: w a. i i w v p O U O v a N - cEl y.v .. g g In H - W z _ iJ K X. su W � o U - W o i , O W F.. a_: ` _a ate 9L ° N H N p O. ° u in � o 0 w LU LU °O = ° O Zo... ' w c n. \ o J b6 a U U cc 4c LU cc LLI: N f d y F d O c LU U 4 Q O J o LU W W � W LL. Lu 1 2 ul m S'BROJECTS'35.17693_WE O'Neil Construction Cd442 S Frontage Rd E, Vail, CO Asbestos Survey.doc x s r• B C i L .l 7 s` t a t � s w o � o` •� V a � b o W o U O 0 CIO p CC bb E-i �. a 00 6 V , W o 0 O vZ N Q•� o wZ>'�c 0 0 N [ .03 Rn Ch tn z � p 4 W °1 p ooi Q o � U O cn N z cd (� Q � U • UzUW kh : . i P r N 61 16'! A "'A V 1, ydw f% pN N. STATE OF COLORADO ASBESTOS CERTIFICATION* Colorado Department of Public+ Health and Environment' Air Pollution Control Division This certifies that Joseph Todd Anderson Certification No: 2157 has met the requirements of 25-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is. hereby certified by the state of Colorado in the following discipline: Inspe'dor/Management Planner*. Issued: 9/26/2005 Expires on: 9/26/2006 Authorized APCD Representative *This certificate is valid only with the possession of a currentDivision-approved training course certification in the discipline speciftedabove. l 1 1 7 7 J 7 l 7 1 J J 7 J 1 � � o rn O . u o s V V = CL O C C v .V W4— O W V. L U O O O e- 6 't N O O O h r V- 0 W � U N z cn O W Q V O W � W Q' U H Q � � U 0 0 o Q c v � I z v J L in 'p v i CZ C: . U o 1 t- m L U � U o' o 'u v m U(L) c L a p -Q O v1 LR1 to v c U . ,O Q) M L QI Q� . U U cz Q Q a M w M O w ? c) 0o , o O M C C> uN � O C CJ v ° �U ro b � a 0 ,o ro v L O O N O M i-� ti z ho 0 a, V W 5 cn o_ U O CL J Z ��,,• �. Jam "/ -. - `+,•,„� .. � - �..,- t � �Y' y._.i..,_sFZ.' 3• �r ! � x..... � �� � � � �a r4; .3{ �_. 4 R•a .ye ffs� 'k S. ll� t+i f 3 1 L- ..1.'3.' 1,.t.�_R € �_5� - ;1•. 4 xccrr ^�R' s r8Y" }•�.. 1 .Tz aT K' ry t .x.x�.,, — - a �� R<rzc*��asc�st !wm �/' ✓ r -- -- CI y ice` ��� F V i C` 1 ej l — — r C-1 l a; 01 T a (u C' a' i.1) 0 C_.1 y p cz ejj cu zj JJJ '�SY � W ' \J � � ._. � • J • V ' V TJ y a.r 3j _ • V Cry '-'", J V =� J O _ 'J = �, . < W —J - W W aj a z I _ i5 �.. .t �, 0 to •� ^ LL. LL Q J IN .n c 'fl J � \. is � y C 00 �,'�u►'1 u o o Z Z Z O o v LL - � `;,•.+ ��� c � � ❑ ❑ ❑ � � may. i �. 1 - it _ r j r ,� `'�` w 7(' `^s %�.a5urfirc` T%ac ..• ;.q'�r .':s..y �� �'?a�m•�.r^•rt� � t ..y e - .tm>. - r't��1"" r, .,.. } .e�.J•.���� . `.... ,� � �-� it • y � a:' _`^ .. �rV� _ y�. ! r �'Lljt��P��'sFi•:it 5i,�, � �� CIL�• . .J t, i i li UO W 94 0 �4 U t NA z u I N ell ;2 Zi 1 ti i " tq to to 34 64 .6.4 in tp th 0 \37, A3 Jg�4, t4l m Z, I ILt ti ti 91 ta.-+ 4 I 9 C PL o1q, TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ASBESTOS Permit #: ASB06 -0018 Job Address: 442 S FRONTAGE RD WEST VAIL Status ...: ISSUED Location.......: APOLLO PARK Applied ..: 08/16/2006 Parcel No....: 210108246023 Issued ...: 09/08/2006 Legal Description: +�V_.�Q (, - v 6 1 Expires ...: 03/07/2007 Project No .: ?? OWNER RON BYRNE 285 BRIDGE ST VAIL CO 81657 APPLICANT VEOLIA ES SPECIAL 5098 PARIS ST. DENVER COLORADO 80239 License: 738 -S CONTRACTOR VEOLIA ES SPECIAL 5098 PARIS ST. DENVER COLORADO 80239 License: 738 -S 08/16/2006 SERVICES, 08/16/2006 Phone: (303) 371 -7600 SERVICES, 08/16/2006 Phone: (303) 371 -7600 Desciption: MOUNTAIN VIEW RESIDENCES- COMPLETE GUT OF ALL DRYWALL AND LINOLEUM Occupancy: Type Construction: Type Occupancy: ?? Valuation: $300,000.00 Add Sq Ft: 0 Fireplace Information: Restricted: # of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0 ************************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY **************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Building ------ > $58.00 Total Calculated Fees - -> $116.00 Plan Check --- > $58.00 Additional Fees ---------- > $0.00 Investigation -> $0.00 Total Permit Fee --------- > $116.00 Payments ------------------- > $116.00 TOTAL FEES ------------- > $116.00 BALANCE DUE --------- > $0.00 Approvals: Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 08/24/2006 DRhoades Action: APPR Approved as submitted. An inspection is required prior to work starting but after set up. Contractor shall provide four (4) full sets of protective gear for VFES to be used in an emergency response. See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residentail Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE FORTY -EIGHT HOURS IN ADVANCE BY TELEPHONE AT 970 -479 -2135 OR 970 -479 -2252 SIGNATURE OF OWNER O 'CO TRACTOR FOR HIMSELF AND OWNEF PAGE 2 CONDITIONS OF APPROVAL Permit #: ASB06 -0018 as of 09 -08 -2006 Status: ISSUED Permit Type: ASBESTOS Applicant: VEOLIA ES SPECIAL SERVICES, INC. (303) 371 -7600 Job Address: 442 S FRONTAGE RD WEST VAIL Location: APOLLO PARK Parcel No: 210108246023 Description: MOUNTAIN VIEW RESIDENCES- COMPLETE GUT OF ALL DRYWALL AND LINOLEUM Conditions: Cond: 38 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479 -2250. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Applied: 08/16/2006 Issued: 09/08/2006 To Expire: 03/07/2007 TOWN OF VAIL, COLORADOCopy Reprinted on 09 -08 -2006 at 14:06:17 09/08/2006 Statement Statement Number: R060001325 Amount: $116.00 08/29/200609:05 AM Payment Method: Check Init: JS ENVIRONMENTAL SERVICES Notation: 46694 /VEOLIA ----------------------------------------------------------------------------- Permit No: ASB06 -0018 Type: ASBESTOS Parcel No: 2101- 082 - 4602 -3 Site Address: 442 S FRONTAGE RD WEST VAIL Location: APOLLO PARK Total Fees: $116.00 This Payment: $116.00 Total ALL Pmts: $116.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 58.00 PF 00100003112300 PLAN CHECK FEES 58.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI(p. � Project #• y f'� Building Permit #: Asbestos Permit #: 777777 TOWN TOWN OF VAIL ASBESTOS ABATEMENT PERMIT APPLICATION TOWN OF VAL - 0im Required per Ordinance No. 19, Series of 1998 75 S. Frontage Rd. Permit application will not be accepted without the following: Vail, Colorado 81657 1. Copies of General Abatement Certificate and State of Colorado Certification 2. A copy of written arrangements with the facility operators for any temporary disabling of the air handling systems, fire sprinkler system, and alarm systems with the names and contact phone numbers of these individuals. 3. Site plan with details addressing: waste container storage location. waste load out area location. entry and exiting details of abatement area. details of entry and exiting plans for the occupants of th structure in unaffected areas. CONTRACTOR INFORMATION On Site Abatement Contractor: Town of Vail' Reg. No.: 11 Contact apd Phone #'s: yGO�IA �. 5er�;�e5 ��g� S � >T gag 7e, 303 - 7zS �7s7 v - 37/ - 2Caoo or E -Mail Address: ✓vt t +yXkLO 00r, C 11 d I'C4 C:5- C-0 Vt_1 Contractor Signature: COMPLETE VALUATION FOR ASBESTOS ABATEMENT PERMIT (Labor & Materials) Asbestos Abatement: $ 5- oc')O • O[7 Contact Eagle County Assessors Office at 970 -328 -8640 or visit www. eagle-county com for Parcel # Parcel, Job Name: Apo L U0 ?Aa- � �� C � F3obAddress: q< Legal Description Lot: Block: Filing: Subdivision: Owners Name: Lo Address : .285 e_ T Project Manager: Address: - �1 nAj � w Yd Phone: 0 - 7/ 76 o o Project Designer: L _� ��� p.� �� Address: Phone: Air Monitoring Specialist: ATE Address: es-& 1c 6LS Ave , -iW Phone:3o3 —Col Detailed description of work: II teen enni� , Co 50117— ­ dl co WcdI av�A Wi4oleu✓m. Start Date: End Date: Start Time: Quit Time: Amount of Asbestos: Linear Feet: Square Feet: ZoI r Doi 55 /Gal Drums: Work Class: New( Addition( ) Remodel( ) Repair ( ) Demo ( ) Other ( ) Work Type: Interior (y- Exterior ( ) Both( ) Type of Bldg.: Single-family Two-family Multi-family Commercial Restaurant Other Does a Fire Alarm Exist: Yes( ) No Does a Fire Sprinkler System Exist: Yes ( .) No * * * * * * * * * * * * ** *FOR OFFICE USE ONLY * * * * * * * * * * * * * * * * * * * * * * * ** Other Fees: Date Received. 'Public Wa` Permit Fee: Accepted By: Occt "an ' Gfoti. F: \cdev \FORMS \PERMITS \Fire \asbestos _perm_12 -5- 05.DOC Page 1 of 1 12/05/2005