Loading...
HomeMy WebLinkAboutF10-0040TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F10 -0040 Job Address: 416 VAIL VALLEY DR VAIL Status ...: ISSUED Location.....: UNIT 15B, RAMSHORN Applied..: 06/17/2010 Parcel No...: 210108258024 Issued . .: 06/28/2010 Project No Expires ..: Payments - - -- > OWNER TYM INTERNATIONAL LTD 06/17/2010 416 VAIL VALLEY DR $0.00 VAIL CO 81657 APPLICANT ALL STATE FIRE PROTECTION, I 06/17/2010 Phone: 303 - 288 -3901 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370 -S CONTRACTOR ALL STATE FIRE PROTECTION, I 06/17/2010 Phone: 303 - 288 -3901 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370 -S Desciption: NEW MULTI- FAMILY DWELLING UNIT: INSTALL FIRE SPRINKLER SYSTEM IN UNIT Valuation: $4,407.50 #;; sfifiti;;;#### i►;f;;;; w###; it;;;;; w ; #wsww #w #f ;sf # #fiti;tRiti # ; iww FEE SUMMARY *****# w;# ss# wswi;;# sRSSSS SS ; # si # #s ;i #sitsi #i #iww #ww ; # ; sR# Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees —> $619.32 Plan Check --- > $432.00 DRB Fee --------- ------- > $0.00 Additional Fees-----> $0.00 Investigation -> $0.00 TOTAL FEES ---- ---- - - --- > $619.32 Total Permit Fee - -> $619.32 Will Call - - - -> $0.00 Payments - - -- > $619.32 BALANCE DUE —> $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 06/24/2010 drhoades Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 -479 -2252 mi OF OWNER OR CONTRACTOR HIMSELF AND OWNEF ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100000739 Amount: $619.32 06/28/201009:18 AM Payment Method: Check Init: SAB Notation: 26779 -ALL STATE FIRE PROTECTION ----------------------------------------------------------------------------- Permit No: F10 -0040 Type: SPRINKLER PERMIT Parcel No: 2101 - 082 - 5802 -4 Site Address: 416 VAIL VALLEY DR VAIL Location: UNIT 15B, RAMSHORN Total Fees: $619.32 This Payment: $619.32 Total ALL Pmts: $619.32 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ BP 00100003111100 SPRINKLER PERMIT FEES - - - - -- 187.32 PF 00100003112300 PLAN CHECK FEES 432.00 4 _. Department of.Community Development- I`+ .75 South Frontage Roo' :Y ors - -1 Y _4 .0 �~�.� ` '! e w � .� :! �."'N r +'+ 7. '+i i.. . 1 e.r ry Y .� -..' � �.(�. � � _ I� : .. • 5 � 1 . _1.r L..l'.r 1 ...i. e��d �'.Iv, r. r'p a� i. �, i ...s, L... •.. e�...... I FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 416 Vail Valley Dr. 15 (Number) (Street) (Suite #) Building /Complex Name: Ramshorn Contractor Information: Company: All -State Fire Protection, Inc. Company Address: 6045 E. 76th Ave., #12 City: Commerce City State: CO Contact Name: Michael Schirado Project #: ��a I 0 CA 50 Building Permit #: TEL l U �� Sprinkler Permit #: { I to —6 0 / "`to Lot #: Block # Subdivision: Detailed Description of Work: Connect t o s Zip: 80022 sprinkler system - provide residential sprinkler protection in suite 15 per NFPA 13. (use additional sheet if necessary) Contact Phone: 303- 288 -3901 E -Mail mikes @allstatefireprotection.com Town of Vail Contractor Registration No.: 3705 XU� Contractor Signature (required) Detailed Location of Work: Third Floo Suite 15 Does a Monitored Fire Alarm Exist? Yes ( () No ( ) Does a Sprinkler System Exist? Yes(. No( ) Property Information Work Class: Parcel #: 2101 -08 -258 -031 New(. Addition ( )Remodel ( Repair( ) (For parcel #, contact Eagle County Assessors Office at 970 -328 -8640 or visit www.eaglecounty.us /patie) Retro -Fit ( ) Other ( ) Tenant Name: Owner Name: W est Coast Partners Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: 15 Type of Building: Single - Family ( ) Duplex ( ) Multi - Family (�) Commercial( ) Restaurant( ) Other( ) Date Received: 'VA►IL FIRE DE�r��T�1�N1[ Approved as Submitted Appro ed as Noted ❑ By: title: - r- D tl - y _ j n C�gf[I n JUN 16 - 200 Qt- Feb -10 , Hydraulic Calculations Project Information Project Name: Ramshorn Lodge Condominiums Address: 416 Vail Valley Drive Vail, Colorado Calculation Area: Suite 15 Date 06/11/10 File # Suite 15B Index 105 Design Criteria Occupancy Classification: Residential Construction ® Combustible ❑ Non Combustible Density: Area of Operation: Area per Sprinkler: Number of Sprinklers Calculated: Hose Allowance 0 gpm inside 100 gpm outside Water Supply Static 130 psi Residual 125 psi Flow 3415 gpm .10 min density N/A 256 sq. ft. max. 4 head Domestic Allowance 0 gpm Sprinklers Make: Viking Freedom Concealed Size: 7/16" K =4.90 Temp: 140° Calculation Summary Total Sprinkler Water Flow: Flow & Pressure: (at base of riser): (at city connection): 106.3 gpm 106.3 gpm @ 206.3 gpm @ 79.9 psi 94.7 psi Notes: SPRINKLER SYSTEM HY DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN JOB TITLE: Ramshorn Condo - Suite # 15 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW NODE PRESS. PRESS. @ TAG (PSI) (PSI) (GPM) DRAULIC ANALYSIS Page 1 CONDOS \CALCULATIONS \SUITE 15B.SDF - 4 Head Calc AVAIL. TOTAL REQ'D PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) S 130.0 125.0 3415.0 130.0 206.3 94.7 Required pressure is 35.3 psi (270) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 206.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 106.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 12 41.1 K= 4.74 29.3 25.6 13 41.1 K= 4.74 29.2 25.6 14 41.1 - - - - 31.0 - - - 15 41.1 K= 4.74 33.7 27.5 16 41.1 - - - - 35.8 - - - 17 41.1 K= 4.74 33.7 27.5 18 41.1 - - - - 35.1 - - - 19 41.1 - - - - 36.1 - - - 20 41.1 - - - - 52.7 - - - 21 42.9 - - - - 53.9 - - - 107 42.9 - - - - 55.1 - - - 108 42.9 - - - - 55.2 - - - 109 42.9 - - - - 55.7 - - - 110 42.9 - - - - 57.3 - - - ill 42.9 - - - - 58.6 - - - 112 42.9 - - - - 58.7 - - - 113 29.0 - - - - 65.0 - - - 119 29.0 - - - - 65.4 - - - 120 18.3 - - - - 70.2 - - - 128 18.3 - - - - 71.1 - - - 129 18.3 - - - - 71.7 - - - 130 9.0 - - - - 75.9 - - - 131 9.0 - - - - 76.3 - - - TOR 9.0 - - - - 77.2 - - - BOR 3.0 - - - - 79.9 - - - BFD 3.0 - - - - 79.9 - - - BFS 3.0 - - - - 92.9 - - - UG1 0.0 - - - - 94.6 - - - S 0.0 SOURCE 94.7 106.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN CONDOS \CALCULATIONS \SUITE 15B.SDF JOB TITLE: Ramshorn Condo - Suite # 15 - 4 Head Calc PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL /FT (PSI) Pipe: 1 -25.6 1.055 PL 10.00 PF 1.7 12 41.1 4.7 29.3 25.6 9.4 150 FTG E PE 0.0 14 41.1 0.0 31.0 0.0 0.133 TL 13.00 PV Pipe: 2 -25.6 1.055 PL 6.33 PF 1.8 13 41.1 4.7 29.2 25.6 9.4 150 FTG T PE 0.0 14 41.1 0.0 31.0 0.0 0.132 TL 13.83 PV Pipe: 3 -51.2 1.055 PL 10.00 PF 4.8 14 41.1 0.0 31.0 0.0 18.8 150 FTG - - -- PE 0.0 16 41.1 0.0 35.8 0.0 0.477 TL 10.00 PV Pipe: 4 -27.5 1.055 PL 6.42 PF 2.1 15 41.1 4.7 33.7 27.5 10.1 150 FTG T PE 0.0 16 41.1 0.0 35.8 0.0 0.151 TL 13.92 PV Pipe: 5 -78.8 1.055 PL 0.33 PF 0.3 16 41.1 0.0 35.8 0.0 28.9 150 FTG - - -- PE 0.0 19 41.1 0.0 36.1 0.0 1.057 TL 0.33 PV Pipe: 6 -27.5 1.055 PL 2.42 PF 1.5 17 41.1 4.7 33.7 27.5 10.1 150 FTG T PE 0.0 18 41.1 0.0 35.1 0.0 0.151 TL 9.92 PV Pipe: 7 -27.5 1.291 PL 8.25 PF 1.0 18 41.1 0.0 35.1 0.0 6.7 150 FTG T PE 0.0 19 41.1 0.0 36.1 0.0 0.056 TL 17.25 PV Pipe: 8 -106.2 1.291 PL 16.58 PF 16.6 19 41.1 0.0 36.1 0.0 26.0 150 FTG EL PE 0.0 20 41.1 0.0 52.7 0.0 0.688 TL 24.08 PV Pipe: 9 -106.2 2.009 PL 10.21 PF 2.0 20 41.1 0.0 52.7 0.0 10.8 150 FTG 2E PE -0.8 21 42.9 0.0 53.9 0.0 0.080 TL 25.21 PV Pipe: 10 -106.2 2.203 PL 1.42 PF 1.2 21 42.9 0.0 53.9 0.0 8.9 120 FTG T PE 0.0 107 42.9 0.0 55.1 0.0 0.077 TL 15.02 PV Pipe: 11 -106.2 2.203 PL 1.50 PF 0.1 107 42.9 0.0 55.1 0.0 8.9 120 FTG - - -- PE 0.0 108 42.9 0.0 55.2 0.0 0.077 TL 1.50 PV Pipe: 12 -106.2 2.203 PL 6.54 PF 0.5 108 42.9 0.0 55.2 0.0 8.9 120 FTG - - -- PE 0.0 109 42.9 0.0 55.7 0.0 0.077 TL 6.54 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN CONDOS \CALCULATIONS \SUITE 15B.SDF JOB TITLE: Ramshorn Condo - Suite # 15 - 4 Head Calc PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL /FT (PSI) Pipe: 13 -106.2 2.203 PL 7.17 PF 1.6 109 42.9 0.0 55.7 0.0 8.9 120 FTG T PE 0.0 110 42.9 0.0 57.3 0.0 0.077 TL 20.77 PV Pipe: 14 -106.2 2.203 PL 2.17 PF 1.3 110 42.9 0.0 57.3 0.0 8.9 120 FTG TG PE 0.0 111 42.9 0.0 58.6 0.0 0.077 TL 17.17 PV Pipe: 15 -106.2 3.334 PL 0.67 PF 0.1 111 42.9 0.0 58.6 0.0 3.9 120 FTG E PE 0.0 112 42.9 0.0 58.7 0.0 0.010 TL 11.17 PV Pipe: 16 -106.2 3.334 PL 13.92 PF 0.3 112 42.9 0.0 58.7 0.0 3.9 120 FTG E PE 6.0 113 29.0 0.0 65.0 0.0 0.010 TL 24.42 PV Pipe: 17 -106.2 3.334 PL 13.67 PF 0.4 113 29.0 0.0 65.0 0.0 3.9 120 FTG 2E PE 0.0 119 29.0 0.0 65.4 0.0 0.010 TL 34.67 PV Pipe: 18 -106.2 3.334 PL 11.21 PF 0.2 119 29.0 0.0 65.4 0.0 3.9 120 FTG E PE 4.6 120 18.3 0.0 70.2 0.0 0.010 TL 21.71 PV Pipe: 19 -106.2 3.334 PL 39.96 PF 0.9 120 18.3 0.0 70.2 0.0 3.9 120 FTG 2ETL PE 0.0 128 18.3 0.0 71.1 0.0 0.010 TL 87.96 PV Pipe: 20 -106.2 3.334 PL 18.67 PF 0.5 128 18.3 0.0 71.1 0.0 3.9 120 FTG 3E PE 0.0 129 18.3 0.0 71.7 0.0 0.010 TL 50.17 PV Pipe: 21 -106.2 3.334 PL 14.00 PF 0.3 129 18.3 0.0 71.7 0.0 3.9 120 FTG E PE 4.0 130 9.0 0.0 75.9 0.0 0.010 TL 24.50 PV Pipe: 22 -106.2 3.334 PL 29.79 PF 0.4 130 9.0 0.0 75.9 0.0 3.9 120 FTG E PE 0.0 131 9.0 0.0 76.3 0.0 0.010 TL 40.29 PV Pipe: 23 -106.2 3.334 PL 35.75 PF 0.8 131 9.0 0.0 76.3 0.0 3.9 120 FTG 4EL PE 0.0 TOR 9.0 0.0 77.2 0.0 0.010 TL 82.25 PV Pipe: 24 -106.2 4.310 PL 7.00 PF 0.1 TOR 9.0 0.0 77.2 0.0 2.3 120 FTG T PE 2.6 BOR 3.0 0.0 79.9 0.0 0.003 TL 34.90 PV Pipe: 25 -106.2 4.310 PL 1.00 PF 0.0 BOR 3.0 0.0 79.9 0.0 2.3 120 FTG - - -- PE 0.0 BFD 3.0 0.0 79.9 0.0 0.003 TL 1.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN CONDOS \CALCULATIONS \SUITE 15B.SDF JOB TITLE: Ramshorn Condo - Suite # 15 - 4 Head Calc PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL /FT (PSI) Pipe: 26 FIXED PRESSURE LOSS DEVICE BFS 3.0 0.0 92.9 0.0 13.0 psi, 106.2 gpm BFD 3.0 0.0 79.9 0.0 Pipe: 27 -106.2 4.095 PL 42.00 PF 0.4 BFS 3.0 0.0 92.9 0.0 2.6 140 FTG 4ET PE 1.3 UG1 0.0 0.0 94.6 0.0 0.003 TL 128.50 PV Pipe: 28 -106.3 6.275 PL 224.00 PF 0.1 UG1 0.0 0.0 94.6 0.0 1.1 140 FTG 5E PE 0.0 S 0.0 SRCE 94.7 (N /A) 0.000 TL 334.00 PV NOTES (HASS) : (1) Calculations were performed by the HASS 8.0 computer program under license no. 50040231 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (2) The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.115 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 28.9 ft /sec at pipe 5. (4) PIPE FITTINGS TABLE Pipe Table Name: ALLSTATE.PIP PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G Ell Tee LngEll ChkVly BfyVly GatVly 4.095 14.40 28.90 8.70 31.80 17.30 2.90 6.275 22.00 47.10 14.10 50.20 15.70 4.70 PAGE: I MATERIAL: Cppr_M HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G Ell Tee LTE ChkVa BFVa GateVa 1.055 3.00 7.50 3.00 7.50 9.00 1.50 1.291 4.50 9.00 3.00 10.50 9.00 1.50 2.009 7.50 15.00 4.50 16.50 9.00 1.50 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN CONDOS \CALCULATIONS \SUITE 15B.SDF JOB TITLE: Ramshorn Condo - Suite # 15 - 4 Head Calc PAGE: N MATERIAL: ED_FLW HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 45 ChkVa BflyVa GateVa 2.203 6.80 13.60 2.70 15.00 8.20 1.40 0.00 0.00 3.334 10.50 22.50 4.50 24.00 15.00 1.50 0.00 0.00 4.310 13.90 27.90 5.60 30.70 16.70 2.80 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN CONDOS \CALCULATIONS \SUITE 15B.SDF JOB TITLE: Ramshorn Condo - Suite # 15 - 4 Head Calc 0 a+ 3 0 .H w a 0 0 N H N H U) O O a' O H 04 � a, -P �D ro zn +p W H 0 0 0 co 0 O N co O O co a, N C7 O Fq 44 0 0 a+ N 0 0 0 N O O H O O N H O O O O O O H O N 9 N O I r co L N H H ��C��w 04 f4 F. nM n�Drxw H� SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 6/11 /2010: \DWG \ALL STATE \RAMSHORN CONDOS \CALCULATIONS \SUITE 15B.SDF JOB TITLE: Ramshorn Condo - Suite # 15 - 4 Head Calc Utility Report: Equivalent K- Factor Calculator Node Sprinkler Pres. Dia. Pipe Ftgs. Total H -W Equivalent Name K- Factor (psi) (in) Len.(ft) Len.(ft) coef. K- factor ----------------------------------------------------------------------- 1 4.90 7.00 0.811 0.50 E 3.50 150.00 4.74