Loading...
HomeMy WebLinkAboutB10-0157NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES . . �owxo�vnQ, ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT SFR BUILD PERMIT Job Address: Location......: Parcel No....: 1459 GREENHIIL CT VAIL 210312403054 OWNER ORLINSKY, DAVID 07/01/2010 103 W 89TH ST NEW YORK NY 10024 APPLICANT BENCHMARK CUSTOM BUILDERS, I 07/01/2010 Phone: 970-926-7309 P.O. BOX 427 34323 Hwy. 6, Edwards CO 81632 License: 715-B CONTRACTOR BENCHMARK CUSTOM BUILDERS, I 07/01/2010 Phone: 970-926-7309 P.O. BOX 427 34323 Hwy. 6, Edwards CO 81632 License: 715-B Description: INTERIOR & EXTERIOR REMODEL Occupancy: Type Construction: Permit #: Project #: Valuation: Total Sq Ft Added: Status . . : Applied . . : Issued . .. : Expires . ..: B 10-0157 PRJ10-0315 ISSUED 07/01 /2010 08/23/2010 02/19/2011 $228,500.00 0 ft�te4R�+�f�VfIrR�MHY'kYrYRiLI/f4��#RfR��fff4Y'�k*�k!}�l4�4ffr1r1r1r�frfrtrtrrtY��kk'R�fAf#RR►f'f`1�RRRYY FEE SUMMARY •,•,•,•,••••,••••«•'•••••••,'•,••••,•••••••••••••,••••••,••••,•,•,•_••,••••••••• Building Permit Fee-----> $1,716.15 Will Cal Fee--------------------> $4.00 Total Calculated Fees-----------> $7,205.65 Plan Check----------------> $1,115.50 Use Tax Fee------------------> $4,370.00 Additional Fees--------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES----------> a7,205.65 Investigation---------> $0.00 Recreation Fee-------------> $0.00 Payments--------- -----> 57,205.65 Total Calculated Fees--------> $7,205.65 BALANCE DUE-------------------> 30.00 •YYtti�k4fMANNRHR�RfrttkYRY44it44flf'wfRxRfr4rtYey'Yi!l+tfROR1r1r1riR1rlrtRYiYrfrAL#f#M/#R�#RRR Vf�kR4R44RtL1tf#+t4ihtA*f'RRR#1rV Y'rtrtit�k#iR4444f1'telritrf`f'RRVfrRfiRfr44ff4441(tffRRfMw4}ffRVRfV �RA'�F'kfYliftt4Jktfe!#Vf1'f DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INS�ECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 q�4�0'P1M. A I , � . � or Contractor � bld_alt construction�ermit_041908 ♦���x�weK�x�r�x�xwwrwys��xx�wxr�ww�::�x��rrwx,t„��x:�rw���rai�:::xxi�er����:������xrx�wx�wrwxwx���xxzs.rr�x��xxxwxrxx�ww«�w��+rxxxxwwww�r�r;x�xx�:�wwx�xx���w+�:���x�+w�wwxxxxxxxrwrew� APPROVALS Permit #: 610-0157 as of 08-23-2010 Status: ISSUED +e:wt������x+x+xw,.��rrr�xxxexxx��t��xwwxwxxxr�«x�xx�wsn.w:ewwx�a►:��xxs.xw,rrwxr�xw,ti.������w,r�errttrt�:xwx�w,.rrwx,r�,���+�xw+xxx�wr��a,r:x�wxx:xxxrw�rxxrww,r:�:xw�iexe,erve+xw+�+,�xww:��xxrwrx Item: 05100 BUILDING DEPARTMENT 07/20/2010 Martin Action: DN Please have the following comments addressed with a re-submittal of the pians: B 10-0157 Sheet A2.02 1. The plans indicate no changes to MEP however the plans reflect the addition of some can lights. Please clarify. If electrical is to be added provide electrical load calculations if circuits to be added. 2. Please provide cross-sectional details of the proposed in fill of the exterior walls. 3. Provide gas pipes sizing calculations for the proposed fireplace and how it is to be connected. 4. Annotate on plans that the cut sheets for the fireplace shall be provided at time of rough inspection. 5. Provide size and u value of new window proposed. 6. Annotate on plans that CO detectors will be installed perlRC. Thank you Martin 08/11/2010 Martin Action: AP Item: 05400 PLANNING DEPARTMENT 07/01/2010 bgibson Action: AP plans routed to A-4 07/26/2010 bgibson Action: AP response to corrections approved. plans routed to A-4. Item: 05600 FIRE DEPARTMENT 07/06/2010 drhoades Action: COND Distance around perimeter is approximately 413 feet. Exceeds IFC 503.1.1 requirement and should be sprinklered. Work occurring not enough to trigger sprinkler requirement. Monitored fire alarm required (see conditions). fttYlYrtYei4Hfl��fltrf}wptf�NwxwRRhxwRfrtYf VR�k�k�k�kYfff�LL�4tfNtttrRRRlrRwfLfxwlrfV 1r4fAkiRfLfA'A'f�kYrFYirtrttYeil4Yl#Mf(f(Yiff�R+�fftiflrtwfw4iRAwLYrf.riYMAYIY'YeYrkYlYif.M11Li(1(f`441(lL��tf�tlffi(ftft4RR!lfffii�rRtrlwlrlrRfwe�+Y See the Conditions section of this Document for any that may apply. bld alt construction_permit_041908 �}ftw�M��#f#R�A1MxwfrtYtfx44R1r��krtfY�Yfffi##�fflffw*1f�##�NRtxxtfRft4f��ww4}iik�kx�#�fw}�►���RtfwY}fW##f�fr#f�fRfffRRfffkYtYtkY*wwkilNfRl���RR}fffflffkkf111fYY�Y�wWf�****�*fff#tlrltf CONDITIONS OF APPROVAL Permit #: 610-0157 as of 08-23-2010 Status: ISSUED •er�rrt,v�x����:�vrwwerrt�-w,vw�:�:ttxwwxwwrt«wwr.w.t+x::::xxxxr�www�:�w�w+�,H,:w:►►x+xxxxrxxxex,ere+vrvrtwwr�+�.axx�xxxwerawrrrxxw�xx�+,Hn.+�x�wxxr�,eerrrr�w�a�wx:rk:::xnw�.:���rxxxwxw+���+.r++���kx: Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 44 (BLDG 2009): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R314 OF THE 2009 IRC, IF APPLICABLE UNLESS A MONITORED FIRE ALARM SYSTEM IS REQUIRED. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 Cond: 51 (FIRE 2007): MONITORED FIRE ALARM SYSTEM REQUIRED AND SHALL COMPLY WITH NFPA 72(2007) AND VFES STANDARDS. bld alt_construction_permit_041908 *********************************************+*******************************+�+�*******«*** TOWN OF VAIL, COLORADO Statement *�*******+****************+**��***********r**+***�***********+**+**************++*�*�******* Statement Number: R100001129 Amount: $6,090.15 08/23/201010:38 AM Payment Method: Check Init: SAB Notation: 2314 BENCHMARK CUSTOM BUILDERS ----------------------------------------------------------------------------- Permit No: B10-0157 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2103-124-0305-4 Site Address: 1459 GREENHILL CT VAIL Location: Total Fees: $7,205.65 This Payment: $6,090.15 Total ALL Pmts: $7,205.65 Balance: $0.00 ***************************************+*********************+*****+************************ ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 UT 11000003106000 WC 00100003112800 Description ------------------------------ BUILDING PERMIT FEES USE TAX 4$ WILL CALL INSPECTION FEE Current Pmts 1,716.15 4,370.00 4.00 ----------------------------------------------------------------------------- BUILDING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: � 1�. � i (Number) (Street (Suite #) Building/Complex Name: Contractor Information: ,. _ Company: �M^������ C.. tF-1C�YV1 f�t1( Id �ei'�{a'� CompanyAddress:i�. 'il��c� City: � State: (�i Zip: �� �P Contact Name: L !�_ �Y'�f Contact Phone: � /d ' ��� 1 �Z� E-Mail ����UryfPl. ii1�'i`C Tow of Vail Contractor Registration No.: ��5� X Contractor Signature ( quired) Property Information U /J Parcel #: � � C7�- ��-1 i� �`(7��! (For parcel #, co�nact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: Owner Name: !/� �� �QL�S V Valuations (Labor & Materials) Building: $ � L� �� V Plumbing: $ � �1 V� Electrical: $� _� Mechanical: (including fireplace) $ y, 6� Total: $�`� �� Office Use: �f � Project#: �I��O'���� DRB#: l�� !�� Building Permit #: Tc/ � V—Q' � t Lot #� Block # Subdivision:IC� �L �1 %V'l Detailed Scope and Location of Work: �� I�.� gA-� �R a.� d.�..�z �,�. i«� .�, =! ���CG W i.�� i� � I V� YI , �ila�t►+' h�(T _ , _ r . � , n_ ,•, . _. _ . � sheet i6necessarvl , . , - Work Class: New ( ) Addition ( ) Remodel � Repair ( ) Other ( ) Work Type Interior ( ) Exterior ( ) Both ( � Type of Building: Single-Famify ( ) Duplex (�) Multi-Family ( ) Commercial ( ) Other ( ) Does a Fire Alarm Exist? Yes (�j No () Monitored Alarm? Yes ( ) No (/j Does a Sprinkler System Exist? Yes () No (� #& Type of Existing Fireplaces: Gas Appliances 1 Gas Log __ Wood/Pellet Wood Burning I #& Type of Proposed Fireplaces: Gas Appliances Gas Log � WoodlPellet Wood Burning _ Date Receiv � � � � � � D � �u� 3 0 20�0 VAI L 15-May-10 *�r*******s*s�***s*********�*r*************�******************�*****��**********�******r�*�* TOWN OF VAIL, COLORADO Statement ��******:*��**�*****����*******�*�*+****s*****��***********************�*************�*****: Statement Number: R100000789 Amount: $1,115.50 07/O1/201002:19 PM Payment Method: Check Init: JLE Notation: 2306 BENCHMARK BUILDERS ----------------------------------------------------------------------------- Permit No: B10-0157 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2103-124-0305-4 Site Address: 1459 GREENHILL CT VAIL Location: Total Fees: $7,205.65 This Payment: $1,115.50 Total ALL Pmts: $1,115.50 Balance: $6,090.15 ******�s�*********ss*�***********r****************************s***�********�*********r****** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 1,115.50 ----------------------------------------------------------------------------- Vail Fire Department Asbestos Testing & Abatement Requirements Asbestos testing and abatement proEects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu- lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testina required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abate- ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: � Will not disturb more than the threshold limits identified above. �Tested negative, or at 1% or below (1 copies of test results included) � Tested positive at more than 1%, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of a� age require testing. • The "1989 Ban" on asbesfos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO3 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire_inspectors@vailgov.com 970-479-2252 www.vailQOV.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303-692-3158 asbestos@state.co. us www.cd �he.state.co. us 15-May-10 Asbestos Inspection and Sampling Report 1459 Greer7hill Ct, South (Init, Vatl, Colorado 81657 Presen ted to: Mr. Rick Kirby Benchmark Custom Builders PO Box 427 Edwards, CO 81632 Performed & Prepared by: Mr. Steve Shurtliff DS Consulting, Inc. PO Box 6864 Avon, CO 81620 (303) 378-1544 Project Details: DSC Project #: 2361 Conducted: June 9, 2010 Homeowner: Doug Vance � �onsulting EXECUTIVE SUMMARY On June 9, 2010, Mr. Steve Shurtliff of DS Consulting, Inc. (DSC) performed a limited inspection and collected asbestos bulk-samples at 1459 Greenhill Ct, South Unit, Vail, Colorado, in order to identify potentially hazardous friable and non-friable asbestos-containing materials (ACM) within the upper level master bathroom of the above-referenced, single family residence that is scheduled for renovations. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (ACM) as a material containing more than 1% asbestos. Mr. Shurtliff performed asbestos bulk-sampling of drywall (surfacing material) in a total of three (3) locations within the bathroom. All three (3) bulk-samples were analyzed by Reservoirs Environmental, Inc. (NVLAP #101896) with all three (3) laboratory results reporting as non-detect for asbestos (see Appendix B for laboratory results). 2 PROJECT OVERVIEW I. Introduction A limited inspection and bulk-sampling for ACM was conducted at 1459 Greenhill Ct, South Unit, Vail, Colorado, by Mr. Shurtliff on June 9, 2010, at the request of Mr. Rick Kirby with Benchmark Custom Builders. Mr. Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix A for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM within the master bathroom. II. Structural Design The structure is a wood-framed, tow-level, single-family residence with attached garage. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report. 3 IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a"TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments No asbestos-containing material (ACM) was identified during the bulk-sampling conducted at 1459 Greenhill Ct, South Unit, Vail, Colorado. A total of three (3) bulk-samples were collected from drywall within the upper level master bathroom of the above-referenced residence. All three (3) bulk-samples tested non-detect for asbestos. 4 VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The quantities are approximations and are subject to field verification: Sample #: DW01-01 Sample Description: Drywall Sample Location: Upper Level Master Bath North Wall Material Classification: Surfacing Material Material Quantity: +/- 275ftz Material Condition: Good Physical Description (layers): White mastic; Brown wallpaper; White joint compound w/white paint; White tape; White joint compound; White d all Asbestos Detected (layers): Non-detect; Non- detect; Non-detect; Non-detect; Non-detect; Non- detect Recommendations: GENERAL - See Section VII Sample #: DW01-03 Sample Description: Drywall Sample Location: Upper Level Master Bath West Wall Material Classification: Surfacing Material Material Quantity: +/- 275ftz Material Condition: Good Physical Description (layers): Light brown wallpaper w/white mastic; White joint compound w/white paint; White tape; White joint compound; White drywall Asbestos Detected (layers): Non-detect; Non- detect; Non-detect; Non-detect; Non-detect Recommendations: GENERAL - See Section VII VII. Recommendations Sample #: DW01-02 Sample Description: Drywall Sample Location: Upper Level Master Bath East Wall Material Classification: Surfacing Material Material Quantity: +/- 275ftz Material Condition: Good Physical Description (layers): Brown wallpaper w/white mastic; White compound w/white paint; Tan drvwall Asbestos Detected (layers): Non-detect; Non-detect; Non-detect Recommendations: GENERAL - See Section VII GENERAL: The laboratory results of the potential ACM sampled at 1459 Greenhill Ct, South Unit, Vail, Colorado, indicate that all three (3) bulk-samples of drywall collected from the master bathroom were reported as non-detect for asbestos. Therefore, no professional abatement activities are recommended to remove the above-referenced material. E APPENDIX A CERTIFICATION STATE OF COL4�tAD4 �� , ,� � �. ASBESTOS �� N �+ ���� CERTIFICATION* ��,x_�'�.''�`�. Colorado Department of Public Heatth and Envirooment Air Pollution Contrc�l Division � This cenifies that ' 's- �:. - t� �k=' Steve Shurtliff -��, ��¢, -�' ��� , :-, , ���` �': Certification No: iSd13 : ��" �` � has met the reyuirements of 2�-7-507, C.R.S und Air Quality Control �'' ' �- Commission Regulation No. 8, Part B, and is hercby certified by thc ���'��. state of Colorado in the foltnwing diseipline: i" �����` : �: ����` Building lnspector* �. .L.-Ll.•. f..�.. � Isaued: 6/12/2009 ��i' Expires an: 6/12l201U � ����f�� 1 Ct � ' Aulh�r4•eE APCD R�resenGtiv¢ � �..�.. (., • rhu n.er/t� �r wa1 �ry ww rn o,�.�.r.. y. ��..nu o�d�..pp...m rroN�.rF,bv.,' �. can�rr.�eee tn rns dis y,t,•„��;n�t a.,�t ��,i . y ., : . _ . _. _ _ __.. �m�Y APPENDIX B LABORATORY ANALYSIS � RE� �►B Res�i-voirs Environmenta/, lnc. June 11, 2010 Steve Shurtliff DS Consulting, Inc. 5366 Flatrock Ct. Morrison CO 80465 Dear Customer, Laboratory Code: Subcontract Number: Laboratory Report: Project # / P.O. # Project Description: RES NA RES 192989-1 None Given 1459 Greenhill Ct., Vail, CO Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your o�ce. RES 192989-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, - _� , _. , � . f � �.,� ---- _�-1--.�-- � -�.�-'",�i l�- � � �____ . _ Jeanne Spencer Orr President ��:-�'���� ���-�.._- Analyst(s): Paul D. LoScalzo Michael Scales Anita Bridges P: 303-964-1986 F: 303-477-4275 Wenlong Liu Rich Wegrzyn Robert R. Workman Jr. 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 2 1-866-RES I-ENV www.reilab.com RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Analysis Type: Turnaround: Date Analyzed: RES 192989-1 DS Consulting, Inc. None Given 1459 Greenhill.Ct., Vail, CO June 10, 2010 PLM, Short Report 24 Hour June 10, 2010 Page 2 of 2 ient a L ��A�k� 4� 0�1�, on on- R. :� � �_. . � � : � Sample ID Number A Sub Asbestos �ibrous Number Y Physical Part � Fibrous Component E Description (%) Mineral � Visual omponents (%) R ; Estimate (°/a % DW01-01 EM 585113 A White mastic 5 ND TR 100 B Brown wallpaper 15 ND 50 50 C White joint compound w/ white paint 15 ND 0 100 D White tape 15 ND 90 10 E White joint compound 15 ND 0 100 F White drywall 35 ND 45 55 DW01-02 EM 585114 A Brown wallpaper w/ white mastic 25 ND 45 55 B White compound w/ white paint 25 ND 0 100 C Tan drywall 50 ND 50 50 DW01-03 EM 585115 A Light brown wallpaper w/ white mastic 15 ND 45 55 B White joint compound w/ white paint 15 ND 0 100 C White tape 15 ND 90 10 D White joint compound 15 ND 0 100 E White drywall 40 ND 40 60 ND=None Detected TR=Trace, <l°/ Visual Estimate Trem-Act=Tremol ite-Ac[inol ite Note: Further analysis by TEM is recommended for organically bound material (i.e. tloor tile) if PLM results are<1 %. Data QA B10-0157: Entries for Item:90 - BLDG-Final 15:31 01/15/2013 Action Comments By Date Unique_ Ke AP JRM 11/26/2010 A000139 136 Total Rows: 1 Page 1