Loading...
HomeMy WebLinkAboutB10-0158NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES .� TOWN OF VAfL ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT SFR BUILD PERMIT Permit #: B10-0158 Job Address: Location......: Parcel No....: 2606 DAVOS TR VAIL 210314204006 OWNER BERNSTEIN, LOIS K. 07/02/2010 10783 E CRESTLINE AVE ENGLEWOOD CO 80111 APPLICANT BURKE HARRINGTON CONSTRUCTIO 07/02/2010 PO BOX 2943 VAIL CO 81658 License: 717-B Project #: Phone:970-376-2256,Burke CONTRACTOR J.B. BUILDERS 07/29/2010 Phone: 970-376-0733 J.B. P.O. BOX 3233 Avon CO 81620 License: 656-B Description: ADDITION 8� EXTERIOR RENOVATION Occupancy: Type Construction: Valuation: Total Sq Ft Added: Status . . : Applied . . : Issued . .. : Expires . ..: PRJ10-0151 ISSUED 07/02/2010 08/04/2010 01/31/2011 $96,950.00 0 ......................................»....,..........,,.,,...._.,....,.,......., FEE SUMMARY .............,,...,,....,...,.....,,..,_.._.......,,,,....,,.x.,,,....._._...,.. Building Permit Fee------> Plan Check--------------------> Add'I Plan Check Hours-> I n v e s t i g a t i o n----- ------------> $972.75 Will Cal Fee---------------------> $632.29 Use Tax Fee---------------------> $0.00 Restuarant Plan Review-----> $0.00 Recreation Fee-----------------> Total Calculated Fees--------> $4.00 $1, 739.00 $0.00 $0.00 $3, 348.04 Total Calculated Fees-------------> Additional Fees-----------------------> TOTAL PERMIT FEES-------------> P a y m e n ts ------------------------------> BALANCE DUE----------------------> $3,348.04 $0.00 $3,348.04 $3,348.04 $0.00 .....................................................,,.�,,..,...,,.....,,,..,......,,_,.,..............,.,,.,,........«.........,,....,..,......__._._,,.............,...,........,,,.._ DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the informatior as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQ STS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 M - • 0 M. � Fs' �! v Signature o Owner or Contractor ate �� � � � � 1 • �,r�y Print Name b Id_a It_con stru ction_perm it_041908 #f�fl�f44k4RRRftRxxffx�Atfft4Ww�www##fwftwtk�k�R���f�##�1t����4�fft�ff�#flfx}�ff��iftttfi��RM�w�wffy�tftiN�fiNlYfwwfwfwwwRwwrt���ff#�R��x��l�����f�fff*�f#l�A�f�ffitxftlntNxxw/wwwYw*wff APPROVALS Permit #: 610-0158 as of 08-04-2010 Status: ISSUED .................................................................. �.,........,....,,,....,,,,,........................,...,.,.....,...............,..,...,...,...,,,.,...., ......,,., Item: 05100 BUILDING DEPARTMENT 07/22/2010 Martin Action: DN See Laser fiche 08/03/2010 Martin Action: AP Item: 05400 PLANNING DEPARTMENT 07/19/2010 RLF Action: AP Item: 05600 FIRE DEPARTMENT 07/12/2010 mvaughan Action: DN property contains asbestos, abatement clearance letter required. 07/20/2010 mvaughan Action: AP asbestos is contained wall that is to be taken out toward end of project. Clearance letter will be issued at that time. No TCO or CO shall be issued until clearance letter is submitted. Item: 05500 PUBLIC WORKS 07/21/2010 cdelles Action: AP ................................................:, �.,..........,,,............,,,.........,.. �......,...,,,.......,,.,...,.,.,...,....,.....,.......,,..,,.,..,.....,....., �.,..,,.,. See the Conditions section of this Document for any that may apply. b I d_a It_co n st ru ct i o n_pe rm it_041908 Yf�#R�tff4f#ilf�wkwwwfw4f�4xf14�A�x�kwRwwlw���t�#iftwff/�Mwww*www�Nkt�x���ff#�i#4#�ffffff�xR�xwkwiex�ffwrt#w����#f�44Rfx41f�fiftxft��fxxkkkkxtki4kwww#www#wwwwwwX#4f�kkA����iA�ff4fff� CONDITIONS OF APPROVAL Permit #: B10-0158 as of 08-04-2010 Status: ISSUED .................................................................................................................................,,....................,..�..,...,,.,....,»,..,...... Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 44 (BLDG 2009): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R314 OF THE 2009 IRC, IF APPLICABLE UNLESS A MONITORED FIRE ALARM SYSTEM IS REQUIRED. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 bld_a It_construction_permit_041908 *********************************************************************+********************** TOWN OF VAIL, COLORADO Statement *********************************************************�**************************+******+ Statement Number: R100000970 Amount: $3,348.04 08/04/201008:24 AM Payment Method: Check Init: SAB Notation: 1004-john barry/jb builders ----------------------------------------------------------------------------- Permit No: B10-0158 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2103-142-0400-6 Site Address: 2606 DAVOS TR VAIL Location: Total Fees: $3,348.04 This Payment: $3,348.04 Total ALL Pmts: $3,348.04 Balance: $0.00 ************************************************+******************************************a ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 PF 00100003112300 UT 11000003106000 WC 00100003112800 Description ------------------------------ BUILDING PERMIT FEES PLAN CHECK FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 972.75 632.29 1,739.00 4.00 BUILDING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: ��� � Office Use: C �6 � i !J0 ✓0.L/e2 d c_ Project #: '� � J ��" G� 7� (Number) (Street) (Suite #) DRB #: � � � i Q Q �2 � Building/Complex Name: Building Permit #: �`�— � �� �"�� �"�'�`�`"�'. �"`�"����' �"" Lot #: Block # Subdivision: Contractor Information: Company: ���.�� ,��/ivlrTtL� ��z/+'lT � Company Address: � Detailed Scope and Location of Work: City: State: Zip: � �'^Si�n�,v� Z��LI�rTiG.✓ /Q� /�d�� Contact Name: � �,v (�TQi`� � Contact Phone: G% %� ^�;3 7G ��.� s'� � � (use additional sheet if necessary) E-Mail �/�GLr7 nt -(.A.NG„c�S T r�/� T ,.�..��.,��.�,�..�».� Town of Vail Contractor Registration No.: X Contractor Signature (required) Work Class: New ( ) Addition (✓ ) Remodel (�) Repair ( ) Other ( ) Work Type Interior (• ) Exterior ( ) Both (✓ ) Property Information Type of Building: Parcel #: �/D.3 '%�.Z ' � ��� '�o Single-Family (✓f Duplex ( ) Multi-Family ( ) (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Commercial ( ) Other ( ) Tenant Name: Owner Name: �/.S � �j�,�s � E/� Valuations (Labor & Materials) 0 Building: $ 7,�' pQD� � Plumbing: $ � p00 � � Electrical: $ � o�e . Mechanical: (including fireplace) $ %�,� ��M Total: $ %� O�D � �� Does a Fire Alarm Exist? Yes () No (✓) Monitored Alarm? Yes ( ) No (� Does a Sprinkler System Exist? Yes () No (vY #& Type of Existing Fireplaces: Gas Appliances � Gas Log Wood/Pellet Wood Burning l #& Type of Proposed Fireplaces: Gas Appliances _ Gas Log � Wood/Pellet Wood Burning _ __... .___.__ . __ _. __ _..._._ __._ ____... Date Received: D � v�� �/ � JUL O 1 2010 TOWI� OF VAIL O1-Jan-10 Generated by REScheck Package Generator Compliance Certificate Project Title: Bemstein Residence Remodel 8� Addition Report Date: Os/07/10 Energy Code: 20061RC �«��� Vail, Colorado Construdbn Type: Single Family Glazing Area Peroentage: 15% Heatln9 �e9nee DaYs: 9248 Climate Zone: g Construdion Site: 2606 Davos Trail Vail , CO 81657 Owner/Agent: Designer/Contractor: Ron Ki�icham Ronald D. Kirkham Architect PO Box 5631 Vail , CO 81658 9703761793 ki�icham.ron�gmail.com Cumpli:ince� P8SS25 '� Ceifing: 49.0 __ Wall: 20.0 0.0 Basement: 19.0 Wall height: 8.0' Depth below grade: 5.0' Insulation depth: 8.0' Window: 0.350 Door: 0.350 Compllanae Statemenh The proposed building design desaibed here is consistent with the building plans, specifications, and other calculadons submitted with the petmit application. The proposed building has been designed to meet the 2006 IRC requiremeMs in the RESchecR Package Generator and to oomply with the mandatory requirements listed in the REScheck Inspedion Checklist. Name - Tide Project Title: Bemstefn Residence Remodel 8� Addidon Data filename: Signature Date � ���o�� JUL O1 20�0 � TOWN OF VAIL I Report date: O6/07/10 Page 1 of 3 Date: 06/07/10 Ceilings: Generated by REScheck Package Generator Inspection Checklist ❑ Ceiling: R-49.0 cavity insulation Commerrts: Note: The ceiling R-values do not assume a raised or oversized truss construcdon. If the insulation achieves the full insulation thiciv�ess over the plate lines of exterior walls, R-30 insuladon may be substituted for R-38 insulation and R-38 insulation may be su�ted for R-49 insulation. Ceiling R-values represent the sum of cavity insulati�on plus insulating sheathing (ff used). Above-Grade Walis: ❑ Wall: R-20.0 pvity insulation Comments: Note: Wall requiremerKs aPPb to wood-irame wall oonstrucdo�. Metal-frame wall or mass (ooncrete, masonry� �09) wall equivalent R-values can be found in the Help Users Guide. Basement Walls: O Basement: 8.0' ht / 5.0' bg / 8.0' insul, R-19.0 cavity insulation Comments: Walk out basement Note: Walls of conditioned basemerrts below uninsulated floors must be insulated from the top of the basement wall to a depth of 10 feet below ground level or to the level of the basement floor, whichever is less. The endre opaque portion of any individual basement wall with an average dep�h Iess than 50% below grade must ►neet the same R-value requirement as above-grade walis. Basement doas must meet tlie door-U-fac�or requirement. Windows: ❑ wndow: U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Breakl CommeMs: Door'S: 0 Door. U-facxor: 0.350 Commerrts: Front door exempt Yes No Note: Door U-values must be tested and documented by the manufadurer in accorclance with the NFRC test procedure or taken from the door U-fador table in the Help User's Guide. If a door cvMains glass and an aggregate U-factor ratlng for that door is not avaitable, indude the glass area of the door with your windows and use the opaque door U-fac;tor to detertnine oomplianoe for the door. One door may be exduded from this requirement (i.e., may hav a U-fador greater than 0.35). Air Leakage: � Jants, penetrations, and all o�her such openings in the building envelope that are sourc�s of air leakage are sealed. � Recessed lights are either 1) Type IC rated with encbsures sealed/gasketed against leaks to the ceiling, or 2) Type IC rated and ASTM E283 labeled, or 3) installed inside an air-tight assembly with a 0.5" dearance from combustible materials and a 3' dearance from insulation. Vapor Retarder. � Vapor retarder is installed on the wam►-in-winter side of atl non-vented framed oeilings, walls, and floors; or it has been determined that moisture or ks freezing will not damage the materials; or other approved means to avoid condensation are provided. Comments: Materials Identification: � Materials and equipment are identified so that oomplia�ce can be determined. � Manufacturer manuals for all instalied heating and cooling equipment and service water heatlng equipment have been provided. Project Title: Bemstein Residence Remodel 8 Addidon Report date: 06/07/10 Data filename: Page 2 of 3 � Insulation R-values and glazing U-factors are deariy marked on the building plans or specifiqtions. 0 Insulation is installed according to manufacturer's instructions, in substantlal contact with the surtace being insulated, and in a manner that achieves the rated R-value wNhout compressing the insulation. Duct Insulation: � Ducts in unconditioned spaces or outside the building are insutated to at least R-8. � Ducts in floor trusses above uncondiiti�oned spaces or above the outdoors are insulated to at least R-6. Duct Construction: � Air handlers, filter boxes, and duct connections to flanges of air distribution system equipment or sheet metal fitGngs are sealed and mechanically fastened. � All joints, seams, and connec�ions are made substantialiy airtight wkh tapes, gasketing, masdcs (adhesives) or other approved dosure systems. Tapes and mastics a►e rated UL 181A or UL 1816. 0 Building framing cavities are not used as supply duds. � Automatic or gravity dampers are installed on all outdoor air intakes and e�diausts. � Additional requirements for tape sealing and metal duct crimping are inGuded by an inspec�ion for c�ornp�fance with the Intemationai Mechanical Code. Temperature ConMols: � Themwstats exist for each separate HVAC system. A manual or automaUc means to partially restrict or shut off the headng and/or cooling input to each zone or floor is provided. Heating and CooUng Equipmerrt Sizing: � Addibonal requirernents for equipment sizing are induded by an inspecdon for c;ompiiarxx� with the Intemational Mechanical Code. Circulating Hot Water Systems: � Circulating hot water pipes are insulated to R-2. � Circuladng hot water systems indude an automatic or accessible manual switch to tum off the arc;ulating pump when the system is not in use. Heating and CooUng Piping Inaulation: � HVAC piping c�nveying fluids above 105 degrees F or chilled fluids bebw 55 degrees F are insulated to R-2. Certiflcate: � A permanent cerdflcate is provided on or in the electrical dishibution panel listing the predominarn insulation R-values; windaw U-factors� type and efficiency of space-oonditioning and water heatlng equipment. NOTES TO FIELD: (Building Deparhnent Use Only) Project Title: Bemstein Residence Remodel 8 Additlon Report date: 06/07/10 Data filename: Page 3 of 3 � ,. . � � ' 2006 IRC Energy Efficiency Certificate Ceiling / Roof . Wall �.� 20.00 Floor / Foundatfon 19 � �uctworic (uncondkbnsd spaoss); �.. . Window • 0.35 0,40 �O°� 0.35 Nq .: .. . . . Headng 8ystem: Cooling System: Water Heabar. Name: Date: Comrrwnts: Asbestos Inspection and Sampling Report 2606 Davos Trail in Vail, Colorado 81657 Presen ted to: Mr. Stan Bernstein Homeowner 2606 Davos Trail Vail, CO 81657 Performed by: Mr. Brandon Sinkbeil DS Consulting, Inc. PO Box 6864 Avon, CO 81620 (970) 476-4182 Project Details: DSC Project #: 2240 Conducted: May 7, 2010 � . Consulting � � � � D JUL Ol ZaiO � TOWf� OF VAf� � EXECUTIVE SUMMARY On May 7, 2010, Mr. Brandon Sinkbeil of DS Consulting, Inc. (DSC) performed a limited inspection and asbestos sampling at 2606 Davos Trail in Vail, Colorado, in order to identify potentially hazardous friable and non-friable asbestos containing materials (ACM) within a portion of the above-referenced residence scheduled for a remodel. Mr. Sinkbeil performed asbestos bulk-sampling of drywall and ceiling texture (surfacing materials) in a total of six (6) locations within the residence (see Appendix A for sample locations). All six (6) bulk-samples were analyzed by Aerobiology and Associates Laboratory, Inc. (NVLAP # 200860-0) with five (5) laboratory results being positive for ACM between 2% and 3% Chrysotile (see Appendix C for laboratory results). i � � . � �t i � �� . � � � � � � _ � � � � � ' � : u Sample Sample Material Friable or Estimated Material Asbestos Location Number Classification Non-Friable uantities* Condidon Content P�pTextureiling pOP-01 Surfacing Material Friable +/- 950 ftz Good 2% Chrysotile P�pTextureling pOP-02 Surfacing Material Friable +/- 950 ft2 Good 2% Chrysotile P�pTextureiling pOP-03 Surfacing Material Friable +�- 950 ft2 Good 3% Chrysotile Wall Drywall DW-02 Surfacing Material Friable +/- 400 ftz Good 3% Chrysotile Wall Drywall DW-03 Surfacing Material Friable +/- 400 ftz Good 3% Chrysotile a�uauuuc, ai c q}�F1� UXiuld[IOI1S 8I1Q SUD)@CC LO [IeIU VeI7r1C2t1017. G PROJECT OVERVIEW I. Introduction A limited inspection and bulk-sampling for ACM was conducted at 2606 Davos Trail in Vail, Colorado, by Mr. Sinkbeil on May 7, 2010, at the request of Mr. Ron Kirkham. Mr. Sinkbeil is a Colorado State Certified inspector, and has EPA Accreditation #13442 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM within the areas of the residence scheduled for a remodel. II. Structural Design The structure is a three-level, wood-framed, single family residence with an attached garage. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if: 1. They exhibit similar physical characteristics; and 2. The application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Method for the Determination ofAsbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report. IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: ■ The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: ■ The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). ■ One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. ■ Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. 4 Response-action recommendations for asbestos containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates an imminent hazard exists and should be addressed as soon as possible. A general recommendation indicates no imminent hazard exists and no further abatement activities are required for removal of the material. V. Inspector Comments ACM was identified during the bulk-sampling conducted at 2606 Davos Trail in Vail, Colorado. A total of six (6) bulk-samples were collected from the above-referenced address. Five (5) bulk-samples tested positive (greater than 1%) for asbestos. ■ Asbestos was identified in the popcorn ceiling texture (surfacing material) sample Nos. POP-01, POP-02, and POP-03 at 2-3% Chrysotile. Asbestos was identified in the drywall joint compound (miscellaneous material) sample Nos. DW- 02 and DW-03 at 3% Chrysotile VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the residence at 2606 Davos Trail in Vail, Colorado, on May 7, 2010. The quantities are approximations and are subject to field verification: �..�� � *rfi�s� .r,`"'��� � ri ��. �° .r: . ;�::..,,. �, o:�:�p ,� -'-�@t�i'�k ;� x �a ^a-�.';, v. .�;;-- ` u ,�,; �. ._ � �. �� t � x � i� ,� -� 4 - ti � � u� t.. ��' = -a'� � _ v �,� a v b; �. Physical Description (layers): White foam ceiling Physical Description (layers): White foam ceili�ng texture texture Material Classification: Surfacing Material Material Classification: Surfacing Material Sample Location: Dining Room Popcorn Ceiling Sample Location: Dining Room Popcorn Ceiling Texture Texture Material Condition: Good Material Condition: Good Material Quantity: +/- 950 ftz Material Quantity: +�- 950 ft2 Sample #: POP-01 Sample #: POP-02 Asbestos Content (layers): 2% Chrysotile Asbestos Content (layers): 2% Chrysotile Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII 5 Homageneous Are� #U2 ' Hor��geneous Area #02 Physical Description (layers): White tape; White foamy texture; White joint compound; White physical Description (layers): White paint; com ound; White tan d all White/tan drywall; White joint compound Material Classification: Miscellaneous Material Material Classification: Miscellaneous Material Sample Location: Basement Bathroom Wall D all Sample Location: Dining Room Wall Drywall Material Condition: Good Material Condition: Good Materia/ Quantity: +�- 400 ft2 Material Quantity: +/- 400 ft2 Sample #: DW-02 Sample #: DW-03 Asbestos Content (layers): None-detected; None- Asbestos Content (layers): None-detected; None- detected; 3% Chrysotile; None-detected; None- detected detected; 3% Chrysotile Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII VII. Recommendations IMMEDIATE: The laboratory results of the potential ACM sampled at 2606 Davos Trail in Vail, Colorado, on May 7, 2010, indicate that five (5) bulk-samples were reported as positive for asbestos between 2% and 3% Chrysotile. Asbestos was identified in the popcorn ceiling texture and the drywall joint compound. Since the above-referenced material is to be removed from the residence and the total quantity exceeds any of the regulatory trigger levels of 50 linear feet on pipes, 32 square feet on other surfaces, or the volume equivalent of a 55-gallon drum, a Colorado-licensed asbestos abatement contractor is required to perform the removal, including formal notification to the Colorado Department of Public Health and Environment prior to the abatement of the ACM. 7 APPENDIX A SAMPLE LOCATIONS � f 6 —'_' ._ 'I6'•D V7` _-____ ��.0 im �._m. -- --------- _�_ �----- ..._.� _ ---...... _ �-----.. - .—. _- ---� 3 IQ' 3 IR° 0 _ Il__D•_ 9 O b __. �'-m° I'-113/4' •? GA� C-,_AR,�,GE) y_io m. r-i �ro.. - `c_ �m•-5 v1• c r.�• b�-m in• - � _._. ._. - ... � 1 4 /•.j• _ # wi.._ � 9 i IR ( 3�. j 3�' �. \ "�.�;�"Z'T':'-.'_.. � �._0. � _ . _ _ A,�. ' o I� o � �•MUD �CC>�:J � � 4t s- nv� v1° S 7 � � ' 4 -O" 9�_p• n � � � Y � Q _-s - � � '' _ . _ � EtvT��.-i s ia� j � � - — I� � + t � �I , . � ..! � uP ;-- Q p 3 � ^ , ` a - � 8 _.._. 3VI' ) Q M p r� o — i.-A�i�Y r�oc� ,i �� g I�^,� •L,4uNDR` � Q � � :. r-s si�• � .� �� ' �°��.._ �"� vs• r-�• �n � ���' ! � � � a -�. — � -- � i,.��; 4..a. � �� � , _ ---- ; � / r-i im . i j._6' II �^ �POWG '�] a� ;; ;r � „ g_-� s•-s aro• a _ � _ .._ � o � : • — � � 4'-D�/O' 4._�.n i� . j v _ __ _ .: ._. _. - � � i...._.. ..- �U� � .� _ 1'-� i/4' " 1 �' , . ~ �'-S 3/4, O 9 L II ! Y _ + � �,.� ' ' _ _.. . . � ' � 9'�H• .... . ]'-1 IR` .. i._ . ��i �� 3V1' 9V7. , �__ 14 -11' � � _"_ _ � 11•�i• �' 1 i --- 1 O I ' C - . . . . I ___ '_ . �... m C�� � i m ��F"ccG. R..O^'1 . R=_= j•iGITGr-!EN I I•=�iNIt�G- ROC`11 , , ; / ; � POP-01 � �•-, �„• i � � � � , � �� � - - � . n � J Q n �'-m' � � � r � . _ /j� � �� I ^ � � � , ' � �` ( _ � �� a � � I ; , 1- "_ � -. ; � _ : +o-. r. s ; �- a _ _.— a � s.z aro• , u� a ie• n�-n v4• O'-5 V4" Q '_..___ -__.—..__ M'-D V! .___._.._..._ _ b•-l• -__ _______._-..._____'_.—. 34'-6 IR" * _'_'__ —_�\ s � POP-02 DW-03 Y POP-03 �--- ---- ----- - -- "=m'. --- - --- _ -- --� - -- -----� �J APPENDIX B CERTIFICATION .- - . . .. ... - .. . . . .. . . . .� n . . . , .yY._g"p..� STATE OF COLORADQ ASBESTOS CERTIFICATION* C'olorado Department c�f Public Health and Environment Air Pollution Control Division This ceriifies thal `� �" ! Brandon Sinkbeil , � ,; :. �; , Certification No: I3442 � � �. f � has met the requiremenis of 25-7-507, C.R.S. and Air Quxlity Cc�nirol Commissiun kegulation No. 8, Part B, and is hereby certified by the �' state of Colorado in the followi►sg diseipiine: � � Building Inspector* Issucd: 5/16/2010 `' Expires on: 5/16/2011 " �� `� �.- ,� ./��f.G',�E� : .�1u ed APCU Represenzaove • T6is ctr►i/icate is �v/id owly r�ffk fAe psxsession o�o ceitewl DitvsJop-eppioveJ nuininx ruurfe certifuatiow iw tke disciplisr speeifud abova :: s_i�s. � _��a:,.r.� x-a� A-�:: �. .. x r...r. ...- .. . .. ��. . . . � . _ � � - ....-.,..-... .. . . . . E � APPENDIX C LABORATORY ANALYSIS 10 ,�,�t,�.�,�..���.��. v�._.n.. � AEROb10�OCjy LAI�ORATORY �ASSOCIATES, INCORPORATED CONSULTING LABpRATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.2323746 • www.aerobioloav.net Client Name DS Consulting, Inc. Date Collected: OS/10/10 Street address 5366 Flatrock Ct. ��a�p �k Date Received: OS/10/10 City, State ZIP Morrison, CO 80465 Date Analyzed: OS/12/10 A�� Brandon Sinkbeil #200860-0 Date Reported: OS/13/10 Client Project Name: 2606 Davos Trail, Vail ProjectID: 102996 Job 1D: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % azea % area % com osition POPO 1 POSITIVE 102996-1 White Foam Ceiling Texture N 1,100% 2% CHRY 9S C POP02 102996-2 POSITIVE White Foam Ceiling Teature N 1,100% 2% CHRY 98 C POP03 POSITIVE 102996-3 White Foam Ceiling Texture N 1,100% 3% CHRY 97 C 102996-4A White Paint N 3,1% Negative 100 B DWO1 102996-4B White Compound N 3,19% Negative 100 C 102996-4C 10% White/Tan Drywall N 3,80% Negative CELL 90 G,M 102996-SA 98% White Tape N 5,3% Negative CELL 2 102996-SB White Foamy Texture N 5,4% Negative 100 C DW02 POSITIVE 102996-SC White Joint Compound N 5,4% 3% CHRY 97 C 102996-SD White Compound N 5,16% Negative 100 C �/ ,/-��i'"� l , ��� t� � - j- e c um ce e Laboratory Analyst . � _ am ump eys -- Asbestos Laboratory Supervisor H = fvnos�te AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Croc�dolite TR = Tremolite Trace=Less Than 1 % Page 1 of 3 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.2323746 CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T=Tar P = Perlite O = Organic B = Binder OP = Opaques D = Diatoms � AERO%IO�OC�'y LAbORATORy �ASSOCWTES, INCORPORATED CONSULTING LABORATORY Certificate of Analysis 13949 W. Colfvc Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloav.net Client Name DS Consulting, Inc. Street address 5366 Flatrock Ct. rn�n n n"' Date Collected: OS/10/10 City, State ZIP Morrison, CO 80465 LN l4�°��J Date Received: OS/10/10 A�� Brandon Sinkbeil �� Date Analyzed: OS/12/10 Client Project Name: 2606 Davos Trail, Vail #200860-0 Date Reported: OS/13/10 Project ID: 102996 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % azea % azea % com osition DW02 102996-SE 15% White/Tan Drywall N 5,73% Negative CELL 85 G 102996-6A White Paint N 3,3% Negative 100 B DW03 102996-6B gp% White/Tan Drywall N 3,42% Negative CELL 20 G 102996-6C POSITI V E White Joint Compound N 3,55% 3% CHRY 97 C � / � 1 r - !�- �: .� �' ,l/ �i j, / ./� i e c um ce e Laboratory Analyst am ump eys Asbestos Laboratory Supervisor r+ — rvnos�te AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trac�Less Than 1% Page 2 of 3 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303232.3746 C�;LL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T=Taz P = Perlite O = Organic B = Binder OP = Opaques D = Diatoms ; � O � �.. a ug� o v�i �U N („) M d 3 � "' a � a � � ..1 .� W e w O � u � � U � Q � C � O � � O � '?T, Z 5� v � 2 O J �s� � O Z y O V �/ N C � Q � 0000,� O O N M a .--i �-. .--� ,� N � � � h � O O O O " � N � � q �' � Ua�'¢ce'o o� „� �a p A p O 0 m �O N �, � �° � V�J LJ > F 0 � O � N V � o—z �Uoo� 5''��� � � �v� � t0 C OW.ti� O n M ° � � a�n�CGU A O .a. Y a C7 0 0 � O � � b'p .T s � A � G 0 % d 0 � � � t� L C � w � � � 0 � � � � l7 U C v `o Y Fi N ♦ ♦ O � d � .D c�d w O � L � � d O R C � o = E caa �+ U � Yt A '� � � O ^ O � 'O � � � U d � C � �C 07) N 'Q L �3 � .� Y YO C W A� � U N i4o .�.� N O' � t y w _ O L � o � r > � E � y � � 'C y � � � V ,.�. O w g� � � � C = � - O y E r o s '� N " = � N y �. � � o � E� � Q' . C o �d E N � = .t.. A � O v �a �, � d .� � a� > ~ � �_ a Q =n W � a� y C • E � � �{,y ..7 F a� � � � NU � N � N � 'O C � 7 O .� c E d V � � � � � w- y � N �.�. � «L. � � o � V E o RI y '� � C � O�O U � E � � .� N fp C � V U �� � � A � '� � i0 � E � V .�E, N O O � � � � � w-p o a � X � A C � � U ti � ! f% � FWC ., .O � � R ac :: � G y N L � 3 � x p, � k7 c �, d w � � ��� � ��% � R �� � a�� � �' U cO � G N - y^ ,n � a i, � � � N R �"' V .� y 4. O • w° � 0 � � 'O A C � � � ^G a O L C � G � N w � o� �� o � V � � � V C � � � y❑ 4 C fO .-d� 'y" 7 � � � �V �y S U = S� � ,c R � � �Vl Q � 0 L" � �p � a a E N O � O ti � � d � O _ G O � � �� ay � � a e� 7 � Nz � Vi H 0 i .y d � ,, o % °' �� � � O >, � O � L O�p O n. � E � R W nq. N L'" w O y ^ 3 S v,' N � � � � y o � O � w o � d ' � r � d y N w � d � N h � R 0 � U � _ 3 a � �s y v y °° C � �� o� Cpp � � ,a 4 �� W a .�i�i � �o d U c = r.�. � � W • a e � ' z a t � .� u a z NF G c7 � V u. .0 O U � � C N O � z d ..7 'z L N y O c O > 0 a � 0 � � U � O n 0 u U � � � � � C 7 E 0 d � • � � L lE U O � y E .�-. s 0 � O N � A S °`' � � O �ib v 7 0 a ..�.7 � z R O � C � � � C _ c > C = 0 d � 7 N � O 0 � � U9 3 .�-1 N � > � w �..� � a 12 Inspect�on Re� uest Re�orting �Q-r��,��� Page 8 Requested Inspect Date: Thursday, April 05, 2012 Inspection Area: CG Site Address: 2606 DAVOS TR VAIL A/P/D Information Activity: 610-0158 Type: A-BUILD Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: Insp Area: CG Owner: BERNSTEIN, LOIS K. Contractor: J.B. BUILDERS Phone: 970-376-0733 J.B. Description: ADDITION & EXTERIOR RENOVATION Reauested Insqection(s) Item: 90 BLDG-Final Requested Time: 09:00 AM Requestor: Phone: Comments: follow u Assigned To: SGR E Entered By: JMONDRAGON K Action: Time Exp: Comment: EMENTS ARE COI�IPCEI�II'AND APPROVED. PLAN ING DENIED. A PLANNING INSPECTION IS REQUIRED WHEN COMPLETE. �I y 1� � 5 Inspection Historv Item: 10 BLDG-FOOTING *'` Approved "` 08/17/10 Inspector: mdenney Comment: Item: 20 BLDG-Foundation/Steel ** Approved `* 08/24/10 Inspector:. s�remmer Comment: need special inspection re�ort Item: 30 BLDG-Framing ** Approved " 08/18/10 Inspector: mdenney Comment: east side roof framing. 10/01/10 Inspector: Martin Comment: Item: 50 BLDG-Insulation "" Approved *" 08/26/10 Inspector: sgremmer Comment: 10/06/10 Inspector: JRM Comment: Item: 60 BLDG-Sheetrock Nail "* Approved `" 10/11/10 Inspector: JRM Comment: Item: 70 BLDG-Misc. "" A roved `" Action: AP APPROVED Action: PA PARTIAL APPROVAL Action: PA PARTIAL APPROVAL Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED 10/11/10 Insp ector: JRM Action: AP APPROVED Comment: LATHE APPROVED 10/11/10 Ins� pector: JRM Action: AP APPROVED Comment: R VALUE ON GLASS APPROVED CONFIRMED Item: 535 DIA - ; Item: 536 DIA - ; Item: 533 PLAN• Item: 420 Sp 10l Item: 542 PLAN 02l Com REPT131 nal rept "• Approved "` �ector: JRM Action: AP APPROVED GEOTECH APPROVED EPDXY OF REBAR DOWELS Approved "* �ector: RFD Action: DN DENIED fhe applicant shall paint below stucco or install landscaping to cover exposed concrete. fhe applicant shall paint the vent on the west side of the structure. fhe applicant shall paint the pipe attached to the meter on the west side of the structure. Run Id: 14314