HomeMy WebLinkAboutM10-0118NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MWWOFVK Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 1370 SANDSTONE DR VAIL Location.....: UNIT 8, EIGER CHALETS Parcel No...: 210312103008 OWNER LOPEZ, IVAN 07/06/2010 PO BOX 6852 AVON CO 81632 APPLICANT ERIC'S PLUMBING & HEATING IN 07/06/2010 Phone: 970 - 524 -0743 PO BOX 112 GYPSUM CO 81634 License: 425 -M CONTRACTOR ERIC'S PLUMBING & HEATING IN 07/06/2010 Phone: 970 - 524 -0743 PO BOX 112 GYPSUM CO 81634 License: 425 -M Desciption: ADDITION & REMODEL: INSTALL RADIANT IN -FLOOR HEAT AND VENTILATION Valuation: $12,100.00 ALL TIMES Permit #: M10-0118 Project #: PRJ10 -0068 Status ...: ISSUED Applied.. 07/06/2010 Issued. .: 07/13/2010 Expires . .: 01/09/2011 Mechanical Permit Fee --- > $260.00 Will Call --- ------- > $4.00 Total Calculated Fees - -> $329.00 Plan Check------------ - - - - -> $65.00 Use Tax Fee ------ > $0.00 Additional Fees--- - - - - -> $0.00 Investigation — ------ — ------- > $0.00 TOTAL PERMIT FEE —> $329.00 Total Calculated Fees - -> $329.00 Payments------------ ---- -> $329.00 BALANCE DUE - - -> $0.00 Item: 05100 BUILDING DEPARTMENT 07/13/2010 JRM Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 42 (BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPEC'jION SE AM - 4 PM. �1+ LL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( Signaturvof Owner or Contractor YV rrl O G 2D Print Name ? - U3 -10 Date m e ch ca n ica I_pe rm it_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100000851 Amount: $329.00 07/13/201002:32 PM Payment Method: Check Init: SAB Notation: 8329 ERIC PLUMBING & HEATING ----------------------------------------------------------------------------- Permit No: M10 -0118 Type: MECHANICAL PERMIT Parcel No: 2103 - 121 - 0300 -8 Site Address: 1370 SANDSTONE DR VAIL Location: UNIT 8, EIGER CHALETS Total Fees: $329.00 This Payment: $329.00 Total ALL Pmts: $329.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - MP 00100003111100 - -- ------------------------ - - - - -- ------ MECHANICAL PERMIT FEES - - - - -- 260.00 PF 00100003112300 PLAN CHECK FEES 65.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Lo C.� Boiler/ Furnace Applicz ik- Mechanical Room Layou I A, r ,n L ' f vr Combustion Air Duct Siz oval listing) Oh Flue or Vent Size w Gas Piping Plan (if appli( / lr Heat Loss Calculations* l � — ❑ Equipment Cut Sheets fr * Not required for same size (BTU) boiler replacement with no system changes, or snow melt Project Street Address: 1350 _ hJ5FG nk Orw<_' S (Number) (Street) (Suite #) Building /Complex Name: 510rZ Chad ETS Contractor Information: Company: 6R I C S P 16 G A Company Address: Po I I -.�- City: G w S y m State: (A zip: 9 1 6 �} Contact Name: 6 (L S' C_ Office Use: a Project #: . w Building Permit #: (6 (u rr, o (( a' Mechanical Permit #: f 1 V Q 1 1 9 Lot #: Block # Subdivision: Detailed Description of Work: 2-fl F.(vor Hel�tT U e6y'L�a V(U h , Contact Phone: 31?o - Y (use additional sheet if necessary) E -Mail C�G n�uv P_ CUevr -lT-< ( < ✓1 er Gas Piping Included Town of Vail Contractor egistration No.: �� ❑ Gas Piping by Others �(ZS ❑ Wood to Gas Fireplace Conversion X Boiler Location��� Contractor Signature (required) �. Interior (XS Exterior ( ) Property Information - - - Number of Existing Fireplaces: Parcel #: (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or I Gas Appliances Gas Logs visit www.eaglecounty.us /patie) . >._ Other ( ) Wood /Pellet Tenant Name: a (0 3 la t 03 0 02 1 Number of Proposed Fireplaces: Gas Appliances Gas Logs Wood /Pellet (Commercial Properties) Owner Name: to PCz Complete Valuation for Mechanical Permit: Mechanical $: Type of Building: i Single - Family ( ) Duplex ( ) Multi - Family (k) Commercial Restaurant( ) Other( Date Received: JUL 06 2010 t& TOWN OF VA! �ol���z Ve�T C:��n� �on -,�o /�ib2 ir '` S o (� D Co ►'fie- P v �- I �r i ►^'� C 0 i� � CAS ��VIe Pr ck�n� vr; Stove, o/, ( 66 � � ►z -y�� Zso 0) oi go° v�) 116,000 6 a �k M Radiant Works Pro Zone List Report 7/1/2010 Project Information Project Number: Project Quote: 1 Project Name: Lopez Renovation Designed For: Eric's Plumbing & Heating 1350 Sandstone Drive Unit #8 Vail, 81657 Design Guidelines: Contact Information Project Assumptions Designed By: Andy Casper Outdoor Temp: -20 `F Company Name: Ferguson Enterprises Inc. Elevation: 8,250 ft Phone Number: 970- 328 -0740 Wind Speed: 13 mph Job Type: Residential R Values - Wails R19, Ceilings R30, Windows & Doors R2. . . , Tubing to be installed under all tubs and showers. Zone Name: Zone 2 Baseboard Zone Name: Zone 1 (Baseboard) Radiant Heatin Radiant Heatin Product: 1/2" RadiantPEX Construction: Slab 0.57 Supply Fluid Temp: 180.0 OF Required Heat: 5,384 BTU /h Slab Thickness: 4.00 in Delta T: 20 OF Panel Load: 6,499 BTU /h Thickness Above Tube. 2.00 in Flows 0.65 GPM Manifold Distance: - -- ft Slab Conductivity: 0.81 BTU /(h-ft- °F) Head: 3.7 ft Glycol %: 0% Slab Conductivity: 0.81 BTU /(h1 - - F) # of Circuits: 1 ft Glycol %: 0% 125 Circuit Length: 300 ft # of Circuits: 1 Room Name I Garage No Floor Covering Tube II I Banded Max Surface Required Heated Area Unheated Area �Spacing �Banded Area tSpacing� Temp Intensity I Required Heat ft ft2 in ft ` in - F IBTU /h ft' BTU /h 280 12 — - -- 85 19.2 5,384 Int Capacity BTU /h 36,319 'oom Name _ntry Tile- wl Mudset : R -0.15 'hower / Sauna Tile - w/ Mudset . R -0.15 I .VIIC IV 3 roduCt: Tube Banded Max Surface Required Heated Area Unheated Area Spacing Banded Area Spacing Temp. Intensity Required Heat Radiant Capacity ft ft in ft in °F BTU /h ft BTU /h BTU /h 155 - -- 12 - -- — 85 16.6 2,577 16,393 108 -- 12 — - -- 85 8.8 956 11.457 _._.. _.. . . , „� r rcm- Q,V4 1 u l urn Zone Name: Zone 2 Baseboard 20 Radiant Heatin Product: 112" RadiantPEX Subfloor Thickness: 0.75 in Construction: Slab 0.57 Supply Fluid Temp: 180.0 OF Required Heat. 3,532 BTU /h Slab Thickness: 4.00 in Delta T, 20 OF Panel Load: 4,501 BTU/h Thickness Above Tube: 2.00 in Flow; 0.45 GPM Manifold Distance: - -- ft Slab Conductivity: 0.81 BTU /(h1 - - F) Head: 2.0 ft Glycol %: 0% 125 ft # of Circuits: 1 Circuit Length: 300 ft 'oom Name _ntry Tile- wl Mudset : R -0.15 'hower / Sauna Tile - w/ Mudset . R -0.15 I .VIIC IV 3 roduCt: Tube Banded Max Surface Required Heated Area Unheated Area Spacing Banded Area Spacing Temp. Intensity Required Heat Radiant Capacity ft ft in ft in °F BTU /h ft BTU /h BTU /h 155 - -- 12 - -- — 85 16.6 2,577 16,393 108 -- 12 — - -- 85 8.8 956 11.457 _._.. _.. . . , „� r rcm- Q,V4 1 u l urn jolsi 5pacjng: 116.00 in )elta T: 20 OF Panel Load - 5,725 BTU /h Subfloor Thickness: 0.75 in -low: 0.57 GPM Manifold Distance: -- ft Subfloor Conductivity: 0.09 BTU /(h•ft• °F) iead- 0.4 ft Glycol %: 0% t of Circuits: 2 :ircuit Length: 125 ft Copyright(c) Watts Radiant 2007 Product: 112" RadiantPEX - Radiant Heatin Construction: UnderFloor Supply Fluid Temp: 160.0 OF Required Heat: 5,856 BTU /h Joist Spacing: 16.00 in Delta T: 20 OF Panel Load: 6,461 BTU /h Subfloor Thickness: 0.75 in Flow. 0.65 GPM Manifold Distance: -- ft Subfloor Conductivity: 0.09 BTU /(h•ft. Head: 0.4 ft Glycol %: 0% Subfloor Conductivity: 0.09 BTU /(h•ft• °F) # of Circuits 3 Glycol %: 0% # of Circuits: 2 Circuit Length: 200 ft Circuit Length: 125 ft Room Name Heated Area W Tut>e Banded Max Surface Required lted Area Spacing Banded Area Spacing Temp. Intensity Required Heat ft in ft in °F BT /h ft BTU /h — 8 — - -- 85 15.8 5,856 int Capacity BTU /h 12,628 I Living ! Dining Area Hardwood- 3/4" : R -0.90 370 I t-one Name: zone 5 - Product: 1 /Z" RadiantPEX Radiant Heatin Construction: UnderFloor Supply Fluid Temp: 160.0 OF Required Heat: 2,900 BTU /h Joist Spacing: 16.00 in Delta T: 20 OF Panel Load. 3,177 BTU /h Subfloor Thickness: 0.75 in Flow: 0.32 GPM Manifold Distance: -- ft Subfloor Conductivity: 0.09 BTU /(h•ft• °F) Head; 0.1 ft Glycol %: 0% # of Circuits: 2 Circuit Length: 125 ft 2oord Name I Guest Bedroom West & Upper Hall Hardwood- 3/ R -0.90 Tube Banded Max Surface Required Heated Area Unheated Area Spacing Banded Area Spacing Temp. Intensity Required Heat Radiant Capacity ft ft in ft in °F BTU /h-ft BTU /h BTU /h 155 -- 8 - -- -- 85 18.7 2,900 5,303 cone Name: zone 6 - Product: 112" RadiantPEX Radiant Heatin Construction: UnderFloor Supply Fluid Temp: 160.0 OF Required Heat: 3,034 BTU /h Joist Spacing: 16.00 in Delta T 20 OF Panel Load : 3,319 BTU /h Subfloor Thickness: 0.75 in Flow: 0.33 GPM Manifold Distance: - -- ft Subfloor Conductivity: 0.09 BTU /(h•ft• °F) Head: 0.1 ft Glycol %: 0% # of Circuits: 2 Circuit Length: 125 ft I Copyright(c) Watts Radiant 2007 2 Radiant Works Pro Zone List Report (cont.) 7/1/2010 one Supply Fluid Temp: Tube Heated Area Unheated Area Spacing Banded Area Banded Max Surface Required Spacing Temp, Intensity Delta T: Room Name W ftin °F EII: ed Hea# Radiant Capacity Guest Bathroom ft 2 29 14 in BT U /h fP U /h BTU / h Tile- w/ Mudset : R -0.15 8 85 15.2 441 1,534 Guest Bedroom East 118 8 Hardwood- 3/4": R -0.90 -- 85 22.0 2,593 4,040 one Supply Fluid Temp: 160.0 °F Delta T: 20 °F Flow. 0.59 GPM Head: 0.1 ft # of Circuits, 4 Circuit Length: 125 ft Required Heat: 5,389 BTU /h Panel Load: 5,938 BTU /h Manifold Distance: -- ft Glycol %: 0% Joist Spacing: 16.00 in Subfloor Thickness: 0.75 in Subftoor Conductivity: 0.09 BTU /(h- ft- °F) ROOM Name Heated Area (Unheated R2 ft Master Bathroom 50 20 Tile- w/ Mudset : R -0.15 Master Bedroom / Closet & Water Clo 241 4 Hardwood- 3/4": R -0.90 Project Summary Total Flow: 3.56 GPM Total Head. 3.70 ft Total Project Panel Load: 35,622.00 BTU /h I 'lease verify all project information for accuracy. Signature: Tube Banded Max Surface Required pacing Banded Area Spacing Temp intensity Required Heat Radiant Capacity in ft in °F I BTU/h-ft2 BTU /h BTU /h 8 - 85 23.7 1,183 2,603 s - -- — 85 17.5 4,206 8,014 Date: I Copyright(c) Watts Radiant 2007 3 N y CL d1 C m m _a Cc 0 o � E 314' Pipe Size M a 5 Bypaea Loop = c 0 o .� E . C _ C O N C', O 9 Q ; f0 E w _. �o c c o m 0 -- a m o A E :a m r CD a m C O « m Q) O O z y O Z = L N cu CL O U � c N a Q Q o U J N_c w � llLLttJJ7 � d a a L O -0 U c N (D O t 0)%J... Q Q. +� a) Q) ez!S ad!d 4 d a- 0 Z p >. v O v az S !d l C: O V azfS ad!d to — to .1 yr CA O O Q J cu > L > – z1 .... --- 3oHMH(7 W MHO (d L ez!S ad!d ,, co N L c O O c ` U) o O t0 o m E C O c F– E> N c > `m c � N I _ Y. O O O O M z oa r C G I 7 � 7 r Z A c , S -4 Jy C Q � N V) � o n r 0 o (r) W dA, I �) --- 0 HO I 11 -09 -2010 Inspection Request Reporting Page 24 7:33 am Vail, CO - City Of Requested Inspect Date: Tuesday, November 09, 2010 Inspection Area: CG Site Address: 1370 SANDSTONE DR VAIL UNIT 8, EIGER CHALETS A/P /D Information Activity: M10 -0118 Type: B -MECH Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: CG Owner: LOPEZ, IVAN Contractor: ERIC'S PLUMBING & HEATING INC. Phone: 970 - 524 -0743 Description: ADDITION & REMODEL: INSTALL RADIANT IN -FLOOR HEAT AND VENTILATION Reauested Inspections Item: 390 MECH -Final Requestor: Comments: 390 -4522 Assigned To: JMONDRAGON Action: Time Exp: Requested Time: 04:30 PM Phone: Entered By: MHAEBERLE K 4) F UV-`Ce_r) Inspection History Item: 200 MECH -Rough ** Approved ** 07/30/10 Inspector: sgremmer Comment: Item: 310 MECH - Heating ** Approved ** 07/30/10 inspector: sgremmer Comment: Item: 315 PLMB -Gas Piping Item: 320 MECH - Exhaust Hoods Item: 330 MECH - Supply Air Item: 340 MECH -Misc. Item: 390 MECH -Final Action: AP APPROVED Action: AP APPROVED REPT131 Run Id: 12146