Loading...
HomeMy WebLinkAboutM09-0122NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MMOFVnd Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 1730 SIERRA TR VAIL Location.....: Parcel No...: 210312312016 OWNER BEDNAR, KENNETH L. - HEYER -B 08/04/2009 LORI L. -JT 2794 NE 5TH ST POMPANO BEACH FL 33062 APPLICANT R & H MECHANICAL LLC 08/04/2009 Phone: (970) 328 -2699 PO BOX 810 EAGLE CO 81631 License: 184 -M CONTRACTOR R & H MECHANICAL LLC 08/04/2009 Phone: (970) 328 -2699 PO BOX 810 EAGLE CO 81631 License: 184 -M Desciption: INSTALL BOILER FOR DRIVE -WAY SNOW MELT Valuation: $14,000.00 L-) � ; It ................*.>»..,. ��.... ... * *. *<.............. *.. * *.. *• " FEE SUMMARY....«.**.*.«........<#***......«««......* . * # *....<...,.. <............... Mechanical Permit Fee --- > $280.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $434.00 Plan Check ------------------- > $70.00 Use Tax Fee ------ > $80.00 Additional Fees------ - - - - -> $0.00 Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $434.00 Total Calculated Fees - -> $434.00 Payments------------ - - - - -> $434.00 BALANCE DUE --------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 08/04/2009 JLE Action: DN NO DRB APPROVAL RECEIVED, MUST BE APPROVED BEFORE PERMIT CAN BE ISSUED 08/17/2009 JRM Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE, Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED ALL TIMES Permit #: M09 -0122 Project #: PRJ09 -0336 Status ...: ISSUED Applied ..: 08/04/2009 Issued . .. 08/18/2009 Expires . .: 02/14/2010 mechcan ical_permit_041908 MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWF -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. / ifure of Ow Print Name Date mechcanical_permit_041908 i MECHANICAL PERMIT Boil e-r/Furn ace ARD111cations MM include: -Mechanical Room Uyout/Pla Dimensions Co bustion A ir Duct Slze and LACallon r/ lu or Vent Size G. a Piping Plan (if applicable) � He t Loss Calculations* o Eq uipment Cut Sheets for Boller/Furnace I qor req jired for same size (87U) boiler replacemenr with no system c4anges, or snow melt Fireplace AR2111catlans MM include-, o . Equipment Cut Sheet"sr r Fireplaces/Log Sets ( Manufacture Manufac Info s Ing make, model & approval listing) eject Street Address: ....... ..... * ....... ... ........ ............ ......... .... /7 T 0 5h -TIZ jmbjr) (Street) (Suite omplex Name: Office Use: Project #: fe,3041_ 2 _f)' Building Permit P: A QA Mechanical Permit #: ' ­ 1 1 \gjt C Informatio Lot #A�� Block Subdivision: J Company: C¢mpa y Address: Detailed Description dWork; lyls�a« 10"flu, City: State: 6-0 zip: F16,31 C-Pntact Name:_& �K'110oy Contact Phone: !ZA) (use additional sheet if necessary) E Mail h – Gas Piping Included Town o Vail ontractor Rist n No. e o Gas Piping by Others ,(3 Wood to Gas Fireplace Conversion Parcel (Fpr pa vl� W% Tenan Single-Family , Duplex Multi-Family ( Valuation for Mechanical Permit: Commercial Restaurant Other !al $: . ..... I......... ..... ....... . ................ . ........ ....................... .. ............ Date Received. br Signature (required) Boiler Location: Interior (X) Exterior Other Information . .. ........ Z-1 o - 1,03 - /7- -o.1 ro fi Number of Existing Fireplaces: I A contact Eagle County Assessors Office at 970-35 ': Gas Appliances ( ) Gas Logs ( )WoodIPellet( -aglecouty.urs/pafle) Number of Proposed Fireplaces: ame: (Commercial Properties) I Gas Appliances Gas Logs Wood/Pellet ..... ..... . Ame: !:Type of Building: q3 9 5( - i q ke E C IF � W FE AUG 0 4 2009 Apr-09 Aug. 4. 2009 12:23PM R&H MECHANICAL No-6798 P. 2 Aug. 4, 2009 12:23PM R &H MECHANICAL y I c 4 O O 0 x 0 a c 0 v 19 d s N A la a No, 6798 P. 3 Aug. 4. 2009 12:23PM R &H MECHANICAL Natural Gas Propane Gas 105' max 105' max 105' max 50' max 105' max 50' max Trinity Ti Series q0"', NY ThrmelInc, quick Reference Guide May 1st 2007 Hard water: Water with hardness higher then 100 ppm Calcium carbonate should incorporate "water softener" prior to entering the appliance or a least clean and flush system and refill with treated water and add additive (Use FERNOX provided with each unit) Venting: Use: Schedule 40, Solid Core, PVC or CPVC must comply with ANS11ASTM D1784 PVC DF441 CPVC Intake: Min. 12" above grade plus snow allowance / Increase immediately from I'i to 3" at the boiler Exhaust: Min, 18" above intake and min. 4" off center/ Increase Immediately from 2 to 3" at the boiler Max vent length: Ti 100: Ti 150: n�Ti 200 : Natural Gas Propane Gas 8 to 9.5% CO 9 to 10.5% CO Natural Gas Propane Gas 4to9 "w /c 9to12 w 1c No, 6798 P. 4 Ti 400 4" Diameter pipe = 30' max Nat. & LP 6" Diameter pipe = 65' max Nat. & LP Count 5' equivalent for each 90 or 45" elbow For both Nat. & LP the CO should be less then 140ppm Gas pressure must be taken at the Gas valve No more then 1" drop, when fired Ti 100 Ti 150 Ti 200 Ti 400 Low: 48 / High 240 Low; 48 / High 240 Low; 40 / High 240 Cow: 35 / High 195 Flame rod: 2.0 to 10, 0 Micro Amps (in the presence of a flame) should be read at FC1 Igniter: When the igniter is cold it should have a resistance of 40 to 100 Ohms Fenwal: The Fenwal powers the igniter with 120V AC The Fenwal provides 24V AC to the gas valve plug using only the 2 outside wires of the harness. The Plug has a rectifier which converts the signal to 24V DC. When testing on the 2 outside wires you should read +/- 15,000 Ohms. During the ignition sequence the igniter will glow for 5 seconds. The Gas valve will then open for 3 seconds for each try; The control will try to ignite 3 times. The Normally open pressure switch is factory set at .15 to .20 Sentry: The Sentry controls the fan speed through a 20 -39V DC signal that is sent to the motor controller. The motor always has 120V AC'wired to it, A -C -T : The A -C -T terminals are DRY contacts ONLY (No voltage what so ever) codes ; ASO, ASC, ER3, ER5, ER6, (see trouble shooting in the install manual) Aug 4. 1009 2009 12:24PM 1 Plumbing Circ. Puma Minimum Flow e &G Pump Grundfos Pump Taco Pump Primary loop pipe diam, 291 165 120 Resistance (x1000) Glycol: Glycol from 0 to 30% mixture is accepted. From 31 to 50% mixture, increase the pump size by one. NOTHING above 50% mixture is allowed. Electrical: Ensure that the polarity is correct before providing 120V AC to the boiler. The black wire must be line voltage. The fan motor is provided with 120V AC directly from the source. The following charts help you find the resistance and measurement of a boiler water probe and outdoor air probeat a given temperature. .......... ... ...__ ......... ...............__ .._......, ___. :...____ _...__.., Water Probe (1M ohm) 250 i 200 .�....._— _..._.... ...,_ .._...— �..... _.._ - - - -- 150 - -.. 100.7_ ..... _ .................. ..._....- - -_ - -- - rv.. -- ,,,.._ ................... ..................... ,,..... . ........... ._.._......... ...__..,__.... ,,, ....._.._._._.-._..... .......... ..... i 3 60 0•� 2,264 1,304 .._._,___.,. __..._,....� ........... .. ......._............_._._,.,... _ Moog - - -• -. - _ . _ 70.000 _... ......._....... I OD,aoo ' S0 000 'D.oW ... ......._,_....._.........._.... ao.000 2P ,000 ,..,._.,...... .. ,._.,.__ . ..__.._...... 10,000 ...................,.,.. E R &H MECHANICAL 469 No.6798 P. 5 Ti 100 Ti 150 200 Ti 400 4.5gpm 6gpm gpm 13gpm NRF -22 PL -30 , -36 (Min. PL -36 UP 15 -42 UP 26 -64 26--99 UP 2699 008 009 011 0011 Min. X " Min. 1 " 1 114" Min. 1 112" 772 469 15 Outside 1oK probe 50 T-m( -raturo (F) 80 54 25 37 26 0 Thank you for choosing NY Thermal curs: I Phone: I Tech Support: I Website: 7:00pm 1 800- 688 -2575 1 800- 688 -2575 1 www.nvthermal.com- Aug. 4, 1 2009 12:24PM R&H MECHANICAL Hee ed f (1p, BTU's OUTPUT: ZFFIC4E 4Cy, All ALTITUDE ONE (2 E OTAL aTUS lN fQEEDZD-, JOB NAM I Vv I P r7� �0 i No. 6798 P. 6 SNO IV MELT TOTAL 87Us.- Dig, �7u TOWN OF VAIL, COLORADO Statement Statement Number: R090001031 Amount: $434.00 08/18/200910:34 AM Payment Method: Check Init: JLE Notation: 15549 R & H MECH ----------------------------------------------------------------------------- Permit No: M09 -0122 Type: MECHANICAL PERMIT Parcel No: 2103 - 123 - 1201 -6 Site Address: 1730 SIERRA TR VAIL Location: Total Fees: $434.00 This Payment: $434.00 Total ALL Pmts: $434.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 280.00 PF 00100003112300 PLAN CHECK FEES 70.00 UT 11000003106000 USE TAX 4$ 80.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 M 08 -28 -2009 Inspection Request Reporting Page 16 8:39 am Vail, CO - City Of Requested Inspect Date: Friday, August 28, 2009 Inspection Area: JRM Site Address: 1730 SIERRA TR VAIL A /P /D Information Activity: M09 -0122 Type: B -MECH Sub Type: ASFR Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: BEDNAR, KENNETH L. - HEYER- BEDNAR, Contractor: R & H MECHANICAL LLC Phone: (970) 328 -2699 Description: INSTALL BQLL�R RIVE -WAY SNOW MELT s: 328 -2699, RESCHEUD FROM 8/27/09 o: JMONDRAGON n: Time Exp: 6 Requested Time: 09:00 AM Phone: (970) 328 -2699 Entered By: JMONDRAGON K Inspection Histo Item: 200 MECH -Rough ** Approved *" 08/20/09 Inspector: JRM Comment: Item: 310 MECH - Heating ** Approved ** 08/20/09 Inspector: JRM Comment: SNOW MELT TUBING Item: 315 PLMB -Gas Piping Item: 320 ME CH - Exhaust Hoods Item: 330 MECH - Supply Air Item: 340 MECH -Misc. Item: 390 MECH -Final Action: ArAPPROVED Action: AP APPROVED REPT131 Run Id: 10182