HomeMy WebLinkAboutB08-0154 Plans�Ty
.t
v-
v
�V.-
METAL DECKING
X
XX.X
2
X
3 XX X 1
XX.X
4
aj
EX)
5 0 X1
12
61 or b:12
1/4"
TYP.
r
EARTH
LB
POUND
AFF
GRAVEL / DRAINAGE
�
CONCRETE
AFG
STUCCO / EIF5 or
LTL
GYPSUM WALL BOARD
ABATT
INSULATION
ii r Weir
ll
• i i
rarrwu
,O
RIGID INSULATION
®
MA50NRY
� n
STEEL / METAL
METAL DECKING
X
XX.X
2
X
3 XX X 1
XX.X
4
aj
EX)
5 0 X1
12
61 or b:12
1/4"
TYP.
r
GLAZING / MIRROR
SECTION OUT 5YMB0L
ELEVATION REFERENCE
ELEVATION 5YMBOL5
REVISION SYMBOL
DETAIL OR PLAN ENLARGEMENT
WINDOW REFERENCE
WINDOW /DOOR 51ZE (FT. 'NJ
DOOR REFERENCE
WALL TYPE REFERENCE
ROOF PITCH SYMBOL
WELD SYMBOL
DRAINAGE FLOW DESIGNATION
ELEVATION KEYNOTE
ABV
ABOVE
LB
POUND
AFF
ABOVE FINISHED FLOOR
�
i i rrr
AFG
t
LTL
LINTEL
AP
r
ii r Weir
ll
• i i
rarrwu
,O
ACOUSTICAL CEILING TILE
�����
- i i
ii•iL`iLii
ADJACENT
MFR
MANUFACTURER
C MEN
r "
i
MO
MASONRY OPENING
AL
ALUMINUM
MATL
MATERIAL
r r
GLAZING / MIRROR
SECTION OUT 5YMB0L
ELEVATION REFERENCE
ELEVATION 5YMBOL5
REVISION SYMBOL
DETAIL OR PLAN ENLARGEMENT
WINDOW REFERENCE
WINDOW /DOOR 51ZE (FT. 'NJ
DOOR REFERENCE
WALL TYPE REFERENCE
ROOF PITCH SYMBOL
WELD SYMBOL
DRAINAGE FLOW DESIGNATION
ELEVATION KEYNOTE
ABV
ABOVE
LB
POUND
AFF
ABOVE FINISHED FLOOR
LT
LIGHT
AFG
ABOVE FINISHED GRADE
LTL
LINTEL
AP
ACCE55 PANEL
LVR
LOUVER
ACT
ACOUSTICAL CEILING TILE
MH
MANHOLE
ADJ
ADJACENT
MFR
MANUFACTURER
ALT
ALTERNATE
MO
MASONRY OPENING
AL
ALUMINUM
MATL
MATERIAL
2,512 GRFA
MAX
MAXIMUM
APPROX
APPROXIMATELY
MECH
MECHANICAL
ADA
AMERICAN DISABILITY ACT
MG
MEDICINE CABINET
A/G
AIR CONDITIONING
MMB
MEMBRANE
ARCH
ARCHITECTURAL
MTL
METAL
BSMT
BASEMENT
M
METER
BRG
BEARING
MW
MICROWAVE
BFG
BELOW FINISHED GRADE
MM
MILLIMETER
BEAM
BEAM
MPH
MILES PER HOUR
BVL
BEVELED
MIN
MINIMUM
BIT
BITUMINOUS
MIR
MIRROR
BLK
BLOCK
M150
M15GELLANEOU5
BLKG
BLOCKING
MR
MOISTURE RESISTANT
BD
BOARD
MULL
MULLION
NAT
NATURAL
BO
BOTTOM OF
NR
NOISE REDUCTION
BOT
BOTTOM
NOM
NOMINAL
BLDG
BUILDING
N
NORTH
OPT
CARPET
NIC
NOT IN CONTRACT
G5MT
CASEMENT
NTS
NOT TO SCALE
GIP
CAST IN PLACE
O.G.
ON CENTER
CLG
GELLING
OP6
OPENING
GTR
CENTER
OFF
OPPOSITE
GT
CERAMIC TILE
OPH
OPPOSITE HAND
CLR
CLEARANCE
055
ORIENTED STRAND BOARD
COL
COLUMN
Op
OUTSIDE DIAMETER
GONG
CONCRETE
OH
OVERHEAD
CMU
CONCRETE MASONRY UNIT
OA
OVERALL
(P)
PAINT
G
CONDUIT
PR
PAIR
CON5T
CONSTRUCTION
PKNG
PARKING
GONT
CONTINUOUS
PVMT
PAVEMENT
GJT
CONTROL JOINT
PED
PEDESTAL
CPR
COPPER
PLAM
PLASTIC LAMINATE
GUST
CUSTOM
PL
PLATE
DEPT
DEPARTMENT
PLUM
PLUMBING
D
DEPTH
PH
PLYWOOD
DTL
DETAIL
PT
PRE55URE TREATED
DIM
PIMEN51ON
P5F
POUNDS PER SQUARE FOOT
DW
1215H WASHER
PSI
POUNDS PER 50UARE INCH
DR
DOOR
PG
PRE -GA5T
DWG
DRAWING
PROP
PROPERTY
QT
QUARRY TILE
OF
DRINKING FOUNTAIN
RCPT
RECEPTACLE
E
EAST
RE:
REFER TO
ELEG
ELECTRICAL
REF
REFERENCE
ELEV
ELEVATIONS
REFR
REFRIGERATOR
EL
ELEVATOR
REINF
REINFORCING
EMER
EMERGENCY
READ
REQUIRED
EQ
EQUAL
RE5
RESILIENT
EQUIV
EQUIVALENT
REV
REVISION
EXH
EXHAUST
RH
RIGHT HAND
EXG
EXISTING
R
RI5ER
EXP
EXPANSION
R45
ROD AND SHELF
EXT
EXTERIOR
RD
ROOF DRAIN
RFG
ROOFING
FOO
FACE OF CONCRETE
RM
ROOM
FOF
FACE OF FIN15H
RO
ROUGH OPENING
FOM
FACE OF MASONRY
R/5
ROUGH SAWN
F05
FACE OF 5TUD5
55
SANITARY SEWER
FIN FL
FINISH FLOOR ELEVATION
(5)
SEALANT
FE
FIRE EXTINOU15HER
5HT
SHEET
FDC
FIRE DEPARTMENT CONNECTION
5HT&
SHEATHING
FHC
FIRE HOSE CONNECTION
SM
SHEET METAL
FEG
FIRE EXTINGUISHER CABINET
SIM
SIMILAR
FPL
FIREPLACE
5PM
SINGLE PLY MEMBRANE
FP
FIREPROOFING
5G
SOLID GORE
FLG
FLASHING
5
SOUTH
FLG
FLOOR
SPEC
SPECIFICATIONS
FD
FLOOR DRAIN
50. FT.
SQUARE FEET
5.57E
STAINLESS STEEL
FO
FOOTING
5TD
STANDARD
FRO
FOUNDATION
5T
S PPIN G
F50
FURNISHED BY OTHERS
5TL
STEEL
FUR
FURRING
gD
STORM DRAIN / SMOKE
GA
GAGE, GAUGE
DETECTOR
GALV
GALVANIZED
5TR
STRINGER
GD
GARBAGE P15POSAL
STRUG
STRUCTURAL
GG
GENERAL CONTRACTOR
SW
SWITCH
CLAM
GLULAM LAMINATED BEAM
SYM
SYMMETRICAL
GL
GLASS, GLAZING
TEL
TELEPHONE
GB
GRAB BAR
TV
TELEVISION
GNP
GROUND
THK
THICKNESS
GWB
GYPSUM WALL BOARD
THR
THRESHOLD
TBD
TO BE DETERMINED
HGR
HANGER
T80
TONGUE AND GROOVE
HOW
HARDWARE
TOP OF SLAB
HDR
HEADER
T51_
TOP OF STEM
HTG
HEATING
TOW
TOP OF WALL
HVAG
HEATING/VENTILATING/ AIR
TS
TOWEL BAR
CONDITIONING
TR
TRAN50M
HT
HEIGHT
T
TREAD
HG
HOLLOW CORE
T5
TUBE STEEL
HM
HOLLOW METAL
TYP
TYPICAL
HORIZ
HORIZONTAL
UG
UNDERGROUND
INCL
INCLUDED
UL
UNDERWRITERS
ID
IN51DE DIAMETER
LABRATORIE5
UNO
UNLESS NOTED OTHERWISE
IBG
INSTALLED BY CONTRACTOR
VAPOR BARRIER
ISO
INSTALLED BY OWNER
VIF
VERIFY W FIELD
!NS
INSULATED
V-
VERSALAM
INT
INTERIOR
VERT
VERTICAL
JT
JOINT
VCT
VINYL COMPOSITION TILE
J5T
J015T
V
VOLTS
JO
JANITOR'5 OL05ET
NO
WASHER / DRYER
KIT
KITCHEN
WC
WATER CLOSET
LAM
LAMINATE
WH
WATER HEATER
LVL
LAMINATED VENEER LUMBER
WAIF
WELDED WIRE FABRIC
LAV
LAVATORY
W
WIDTH / WATTS / WEST
LH
LEFT HAND
WF
WIDE FLANGE
L
LENGTH / STEEL ANGLE
WDW
WINDOW
WITH
Ho
WITHOUT
WD
WOOD
WP
WATERPROOF /
WEATHERPROOF
GENERAL NoTme
01. DO NOT SCALE DRAWINGS.
02. VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON THE JOB 517E
PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF
ANY CONFLI6T5 OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
03. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH
WRITTEN APPROVAL FROM THE ARCHITECT BEFORE CONSTRUCTION CONTINUES IN TH05E
AREAS.
04. PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE UNLESS NOTED
OTHERWISE. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF
PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLE55 NOTED OTHERWISE.
05. PROVIDE ALL NEGE55ARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS
INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL- MOUNTED FIXTURES, TOILET5,
TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, 5HELVE5, CLOSET RODS, FAUX
BEAMS, AND LIGHT FIXTURES.
Ob. COORDINATE ALLRELEGTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN THE
FLOOR AND /OR WALL 5PAGE5 AS SHOWN.
01. VERIFY ELECTRICAL ROUGH -IN LOCATIONS FOR ALL APPLIANCES AND LIGHT
FIXTURES. IMMEDIATELY NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES
WITH THE INFORMATION PROVIDED HEREIN OR AFTER DETERMINING EXISTING FIELD
CONDITIONS.
0&. VERIFY PLUMBING ROUGH -IN LOCATIONS FOR ALL APPLIANCES AND FIXTURES.
0q. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE 15 NEEDED BY THE
GENERAL CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF TH15 PROJECT,
HE /SHE SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE AMPLE NOTICE
SHALL RELIEVE THE ARCHITECT OF RESPONSIBILITY FOR DELAYS TO THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR 5AT15FYINO ALL
APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. CODE
COMPLIANCE 15 MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT
WORK THAT DOES NOT CONFORM TO RELEVANT CODES GOVERNING TH15 PROJECT.
H. THE GENERAL CONTRACTOR AND SUBCONTRACTOR5 SHALL FIELD COORDINATE AND
OBTAIN APPROVAL FROM THE ARCHITECT/ ENGINEER BEFORE ANY CUTTING, NOTCHING
OR DRILLING OF ANY CAST -IN -PLACE CONCRETE, STEEL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
BUILDING.
12. ALL ELECTRICAL WORK IN THIS PROJECT 15 TO BE COMPLETED IN A WORKMANLIKE
FASHION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT VERSION OF
THE NATIONAL ELECTRICAL CODE [NEC] ADOPTED BY THE GOVERNING MUNICIPALITY.
13, ALL PLUMBING AND VENTILATION WORK IN TH15 PROJECT 15 TO BE COMPLETED AS
ADOPTED BY THE GOVERNING MUNICIPALITY IN A WORKMANLIKE FASHION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT VERSION OF THE
INTERNATIONAL PLUMBING CODE [11*01, INTERNATIONAL MECHANICAL CODE [IMO] AND
NATIONAL FIRE PROTECTION ACT [NFPA].
14. SUBSTITUTIONS OF "EQUAL" OR "EQUIVALENT" PRODUCTS WILL BE ACCEPTABLE ONLY
WITH OWNER'S AND ARGHITEGT'5 WRITTEN APPROVAL. THE GENERAL CONTRACTOR
SHALL SUPPLY SUBMITTALS DETAILING THE PRODUCTS SPECIFICATIONS, FEATURES,
ETC...
15. IT 15 THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE CONTRACTOR AND
EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, SUPPLIES,
EQUIPMENT, ETC., TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF
THE INDUSTRY.
16. COORDINATE ALL CABINETRY CONFIGURATIONS WITH OWNER PRIOR TO ROUGH -IN.
COORDINATE ALL TRIM PROFILES AND CONFIGURATIONS WITH ARCHITECT.
COORDINATE ALL INTERIOR FINISHES WITH ARCHITECT, OR REFER TO FIN15H SCHEDULES
11. THE GENERAL CONTRACTOR AND ALL TRADES SHALL REFER TO ALL
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND ANY /ALL
OTHER SPECIALTY CONSULTANT/ENGINEER DRAWINGS ATTACHED TO THESE PLANS IN
ORDER TO FULLY DETERMINE THE SPECIFICATIONS FOR ALL MATERIALS USED ON TH15
PROJECT. IF THERE ARE ANY CONFLICTS OR CM155ION IN THE PLANS OR
SPECIFICATIONS IT 15 THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO
CONTACT THE ARCHITECT AND /OR THE OWNER TO RE50LVE THE ISSUE.
18. INSULATION SHALL BE EITHER PAPER FACED FIBERGLA55 BATTENS WHICH EQUAL
THE R -VALUE STATED OR A COMBINATION OF FIBER6LA55 BATTENS AND RIGID FOAM
WHICH 15 EQUAL TO THE SAME R- VALUE. DO NOT CREATE INTERMEDIATE DEW POINTS.
ROOF SYSTEM = R -38 / EXTERIOR WALLS = R -11 / INTERIOR WALLS = R -13 / EXTERIOR
FLOORS = R -38
19. WINDOWS SHALL BE DOUBLE OR TRIPLE PANE 'LOW E' AS RATED BY THE
MANUFACTURER. ALL EXTERIOR DOORS SHALL BE IN50LATED AND /OR WITH INSULATED
6LA55 EQUAL TO THE WINDOWS. WEATHER STRIPPING AND FLASHING AT WINDOWS AND
DOORS SHALL BE TIGHT TO THE WEATHER AND MADE 50 AS NOT TO ALLOW LEAKAGE
AT ANY JOINTS,
20 ALL WINDOW5, DOORS, ROOF JOINTS AND OTHER AREAS SUBJECT TO MOISTURE
INTRUSION SHALL BE PROPERLY FLASHED AND COUNTER- FLA5HED WITH A
NON - CORROSIVE FLASHING WHICH MEETS IBC STANDARDS AND SHALL NOT LEAK OR
DETERIORATE FROM WEATHER.
21. THE CONTRACTOR SHALL FURNI5H TO THE OWNER, ALL WRITTEN d GRAPHIC
MATERIALS WHICH MAY COME WITH ANY /ALL EQUIPMENT, APPLIANCES, HARDWARE AND
SYSTEMS INCLUDING WARRANTIE5, INSTRUCTION MANUALS, AND THE INSTALLERS $
MANUFACTURERS NAME AND ADDRESS, ALL EQUIPMENT, SYSTEMS, FIXTURES AND
APPLIANCES INSTALLED SHALL HAVE A MINIMUM OF A ONE (1) YEAR WARRANTY THE
CONTRACTOR FURTHER WARRANTS AGAINST FAILURE OF ALL VARIOUS SYSTEMS
INSTALLED, CONSTRUCTED OR CAUSED TO BE INSTALLED FOR THE PERIOD OF ONE (1)
YEAR AFTER DATE OF FULL OWNER ACCEPTANCE. SEE ATTACHED PROJECT MANUAL
AND CONSTRUCTION SPECIFICATIONS, IF APPLICABLE, FOR MORE DETAILS.
22, PROVIDE NECESSARY TEMPORARY SHORING AND BRACING TO SUPPORT AND
PROTECT PORTIONS OF THE EXISTING BUILDING DURING DEMOLITION OPERATIONS.
LEAVE SUCH SHORING IN PLACE UNTIL PERMANENT 5UPPORT5 HAVE BEEN INSTALLED.
BE 50LELY RESPONSIBLE FOR DESIGN, SAFETY AND ADEQUACY OF TEMPORARY
SHORING AND BRACING AND ITS ABILITY TO CARRY LOAD OF WHICH INTENDED
23. NOTIFY ARCHITECT IMMEDIATELY IF 5AFETY OF EXISTING STRUCTURE APPEARS TO BE
ENDANGERED. TAKE PRECAUTIONS TO PROPERLY SUPPORT THE STRUCTURE.
24. CONTRACTOR TO VERIFY ALL FLOOR 5UBSTRATE ELEVATIONS FOR LEVEL FINISHED
FLOOR RELATION5HIP5 PRIOR TO CONSTRUCTION.
25. ALL CLOSETS TO HAVE ROD AND SHELF UNLE55 OTHERWISE NOTED.
26. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL REGULATIONS,
CODES, AND REQUIREMENTS OF AUTHORITIES HAYING JURISDICTION.
L A SMOKE DETECTOR 15 REQUIRED ON THE CEILING OR WALL AT A POINT CENTRALLY
LOCATED IN THE CORRIDOR OR AREA GIVING AGCE55 TO EACH SLEEPING AREA.
2. A SMOKE DETECTOR 15 REQUIRED ON THE CEILING OR WALL IN EACH 5LEEPING AREA
3. A SMOKE DETECTOR 15 REQUIRED ON ALL STORIES. IF THE UPPER LEVEL CONTAINS
SLEEPING ROOM(5), A SMOKE DETECTOR 15 REQUIRED IN THE CEILING OF THE UPPER
LEVEL CLOSE TO THE STAIRWAY.
NOTE: A SMOKE DETECTOR 15 REQUIRED IN THE BASEMENT.
4. SMOKE DETECTORS ARE REQUIRED TO BE WIRED TO THE BUILDING'S POWER SOURCE
AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. ALL SMOKE DETECTOR5 5HALL BE
INTERCONNECTED.
5. SMOKE DETECTORS 5HALL 5OUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE
DWELLING IN WHICH THEY ARE LOCATED.
Cs BNrmR4L.
1. PROVIDE OUTLETS AT NO GREATER DISTANCE THAN 6' -0" APART (E3801.2.1)
2. AT WALLS ABOVE GOUNTERTOP5 GREATER THAN 12 ", PROVIDE OUTLETS AT A MINIMUM
OF EVERY 24"
3. PROVIDE MINIMUM OF (1) &FI OUTLET IN BATHROOMS WITHIN 36" OF THE OUT51E EDGE
OF LAVATORY BASIN.
4. ALL ELECTRICAL WORK SHALL BE ENGINWEERED ON A DESIGN MILE? BASIS
U0411L L I *T ,+" E S:
1. ALL NEW INTERIOR WALLS TO BE 2X4 WOOD 5TUD5 a 16" D.C. UNLE55 OTHERWISE
NOTED.
2. ALL NEW EXTERIOR WALL5 AND INTERIOR PLUMBING SHALL BE 2Xb WOOD 5TUD5
16" O.G. UNLESS OTHERWISE NOTED.
GENERAL LIGHT ANC� VENTILATION
I. ALL GUEST AND HABITABLE ROOMS SHALL BE PROVIDED WITH NATURAL LIGHT THROUGH
EXTERIOR GLAZED OPENIN&5 NO LESS THAN ONE -TENTH OF THE FLOOR AREA WITH A
MINIMUM OF 10 SQUARE FEET.
2. ALL GUEST AND HABITABLE ROOMS SHALL BE PROVIDED WITH NATURAL VENTILATION
BY MEANS OF OPERABLE EXTERIOR OPENINGS WITH AN AREA OF NO LE55 THAN 1/20 OF
THE FLOOR AREA WITH A MINIMUM OF 5 SQUARE FEET OR PROVIDED WITH A MECHANICAL
VENTILATING SYSTEM PER IBC REQUIREMENTS.
3. ALL BATHROOMS, WATER OL05ET COMPARTMENTS AND 51MILAR ROOMS TO BE
PROVIDED WITH NATURAL VENTILATION THROUGH EXTERIOR OPENINGS OF NO LE55 THAN
1/20 OF THE FLOOR AREA WITH A MINIMUM OF 1 -112 SQUARE FEET OR PROVIDED WITH A
MECHANICAL VENTILATING SYSTEM PER IBC REQUIREMENTS.
4. LAUNDRY VENTILATION INTERCONNECTED W/ LIGHT SWITCH
DRAWING INDEX
TH TITLE SHEET
TI.2 GRFA SUMMARY / CALCULATIONS
DPI EXISTING FIRST FLOOR DEMOLITION PLAN
DP2 EXISTING SECOND FLOOR DEMOLITION PLAN
DP3 EX15TINO ROOF PLAN
ALL NEW FIRST FLOOR PLAN
A1.2 NEW SECOND FLOOR PLAN
A1.3 NEW THIRD FLOOR PLAN
AI A NEW ROOF PLAN
AILO NEW FIRST FLOOR REFLECTED CEILING PLAN
AILI NEW SECOND FLOOR REFLECTED CEILING PLAN
AI1.2 NEW THIRD FLOOR REFLECTED CEILING PLAN
A2.1 NEW SOUTH AND SOUTHWEST EXTERIOR ELEVATIONS
A2.2 NEW EAST AND NORTHEAST EXTERIOR ELEVATIONS
A2.3 NEW NORTH AND WEST EXTERIOR ELEVATIONS
A3.1 NEW BUILDING 5ECTION5
A3.2 NEW BUILDING SECTIONS
A33 NEW BUILDING SECTIONS AND DETAILS
Ab.l DETAILS
Ab.2 DETAILS
A1.1 DOOR, WINDOW AND ROOM FIN15H SCHEDULES
52.0
GENERAL NOTES
52.1
MAIN LEVEL FRAMING PLAN
52.2
UPPER LEVEL FRAMING PLAN
52.3
ROOF FRAMING PLAN
53.1
FRAMING DETAILS
53.2
FRAMING DETAILS
MO.I MECHANICAL LEGEND
MO.2 MECHANICAL 5PEGIFICATION5
MO.3 MECHANICAL SCHEDULES
MOA MECHANICAL SCHEDULES
M1.1 FIRST FLOOR MECHANICAL PIPING PLAN
MI.2 SECOND FLOOR MECHANICAL PIPING PLAN
M13 THIRD FLOOR MECHANICAL PIPING PLAN
M2..1 FIRST FLOOR MECHANICAL DUCTWORK PLAN
M2.2 SECOND FLOOR MECHANICAL DUCTWORK PLAN
M2.3 THIRD FLOOR MECHANICAL DUCTWORK PLAN
M3.J MECHANICAL DETAILS
M3.2 MECHANICAL DETAILS
P0.1 PLUMBING LEGEND 8 SPECIFICATIONS
P0.2 PLUMBING SCHEDULES
PI.I FIRST FLOOR PLUMBING PLAN
PI.2 SECOND FLOOR PLUMBING PLAN
P13 THIRD FLOOR PLUMBING PLAN
P2.1 PLUMBING DETAILS
RENOVATION AND ADDITION TO EXISTING RE5IDENGE. RENOVATION TO BE AT THE
AREAS OF THE EXISTING SECOND FLOOR LEVEL AND NEW CONSTRUCTION, ADDITION OF
A THIRD FLOOR LEVEL, WITH IN THE EX15TINO 5EGONO FLOOR VOLUME.
CLJNER / DEVELOPMR:
OERARDO SCHROEDER
11 TUNA PUNA LANE
CORONADO, GA 12118
♦ i � i► ` i • • i ► I
` i tL•� st i
MONROE 4 NEWELL ENOINEERS, INC.
HANNE5 SPAEH, P.E., M.5G, DIPL, INC
10 BENCHMARK ROAD, SUITE 204
P.O. BOX 1517, AVON, COLORADO 81620
PHONE: q7tO.014q.1168 / PAX: 110.1-141.4054
E -MAIL: avon®monroe- noHoll.Gom
fi"I C1 -�.II LU1'�'1`S INS. MN(2INMERS;
M -E ENOINEER5, INC.
MIKE DAY P.E. - MECHANICAL / PLUMBINO
245 CHAPEL 5OUARE, SUITE 200
P.O. BOX 5740, AVON, COLORADO 81620
PHONE: 170.g41.6000 / PAX: g70.14q.1g5q
EMAIL: mday @me- engineers.Gom
I
-BUILDING OCCUPANT LOAD;
I,SOq 50. FT. / 30 GROSS = 60 OCCUPANTS
LEVEL ONE: (ART GALLERY)(M).
I,810 50. FT. l 200 GROSS = 10 OCCUPANTS
LEVEL TWO: ( R- 2 ) ..............................
615 50. FT. / 200 OR055 = 4 OCCUPANTS
LEVEL THREE: (R- 2) .........................
4,314 50. FT. = 14 OCCUPANTS
41 GRFA
OCCUPANCY LOAD 200 GROSS, PER TABLE 1004.1.2
GOVERNIN CODES:
2003 IBC, 2003 I FC, 2003 I MC, 2003 NEC, 2003 ]PC,
A LOWABLE BUILDING AREA PER 2003 IBC TABLE 503 FOR VB CONSTRUCTION
M = I / q,O00
R -2 = 2 / 1,000
-IS GRFA
ACTUAL BUILDING AREAS
250 GRFA
M = ONE FLOOR AT I,&cIO
R -2 = TWO FLOOR AT 2,b65
568 GRFA
FLOOR AREAS ABOVE ARE CALCULATED FOR BUILDING CODE REVIEW. SEE ZONING
REQUIREMENTS BELOW AND ON SHEET TI.2 FOR G.R.F.A. S.F. CALCULATIONS
ZONING 'E(2u1Rrmry I1T6:
SPECIAL DEVELOPMNET DEI5TICT REQUIREMENTS
ADDITION:
250 ORDNANCE, AND INTERIOR CONVERSATION OF 110 GRFA
G.R.F.A. SUMMARY
AREA
;f ADDITIONAL GRFA A=
114 GRFA
B=
101 GRFA
G=
41 GRFA
TOTAL (250 ORDNANCE) + IS S.F AT FIRST FLOOR
CONVERTED FROM RESIDENTIAL
268 GRFA
GRFA CONVERTED FROM RESIDENTIAL TO
COMMERCIAL AREA AT THE FIRST FLOOR
-IS GRFA
TOTAL 250 GRFA AT THE RESIDENTIAL AREAS
250 GRFA
INTERIOR CONVERSION
ALL INTERIOR CONVERSION AT THIRD FLOOR
568 GRFA
GRFA CALCULATIONS EXISTING
PROPOSED
FIRST LEVEL FLOOR PLAN 114 GRFA
016 GRFA
SECOND LEVEL FLOOR PLAN 1,580 GRFA
1,&01 GRFA
THIRD LEVEL FLOOR PLAN - - - - - --
615 GRFA
TOTALS I bg4 GRFA
2,512 GRFA
250 ORDNANCE PLUS INTERIOR
•r
CONVERSION SQUARE FOOT TOTALS
818 GRFA
\:J
l!'1►J
FOR :UILDER PERMIT AND PLAN
REVIEW ONLY NOT FOR CONSTRUCTION
fi
TITLE SHEET
•
�
•r
i.
s
FOR :UILDER PERMIT AND PLAN
REVIEW ONLY NOT FOR CONSTRUCTION
fi
TITLE SHEET
co
1p
La
"A
co ,:4F7
co
o L6
C4 CO
00
E
0 0
13
CL
tm
r_ 0
,c LL
0
00
C,
**X
EX15TINC-
TO RES11
ABOVE
"^IZJ I F J.-MIL11% ENTRANCE
ENTRANCE TO COMMON
AREA BASEMENT
NEN FI LEVEL FLOOR PLAN
� 1 50ALE: I / all - it - oil O.R.F.A. = qb
; HALL TO BE REMOVED
; STAIR TO BE REMOVED
HATCH PATTE
:.:NTRANCE TO NEN INDICATES Al
ITIAL 5TORA(5E SQUARE FEEI
3TAIR5 ORDNANCE
O.R.F.k TO BE
TO
L AREA
EXISTINO FIRST LEVEL FLOOR PLAN
50ALE: 1/5" - 11 - oil O.R.F.A. = 114
NEN SEC,/OND LEVEL FLOOR PLAN
50ALE: I / a" -- I'- a" 6.R.F.A. = IWI
EXISTING SEC.-OND LEVEL FLOOR PLAN
50ALE: I / 6" = V- 01- I,580 O.R.F.A.
5
HATC
INDIC
5QUA
ORDIS
HATO
PROF
,-^01,
L-fl—jB-/114 /nfNL-/n
1EN THIRD LEVEL FLOOR PLAN
SCALE- I / a" = 1' - 0" C7.R.F,A. = 615
O.R.F.A. SUMMARY
AREA
ADDITIONAL ORFA gt. 8,1441
-,qRw
TOTAL (250 ORDNANCE) + 0 5.F AT FIRST FLOOR
CONVERTED FROM RESIDENTIAL
ORFA CONVERTED FROM RESIDENTIAL TO
COMMERCIAL AREA AT THE FIRST FLOOR
8',,'6RFA,
TOTAL 250 ORFA AT THE RESIDENTIAL AREAS
250 ORFA
INTERIOR CONVERSION
ALL INTERIOR CONVERSION AT THIRD FLOOR
568 &kFA
ORFA CALCULATIONS EX15TIN(5
PROPOSED
FIRST LEVEL FLOOR PLAN 114 ORFA
% ORFA
SECOND LEVEL FLOOR PLAN I,580 ORFA
IWl ORFA
THIRD LEVEL FLOOR PLAN -------
615 GRFA
TOTAL5 If084 ORFA
2,512 ORFA
250 ORDNANCE PLUS INTERIOR
to
CONVERSION SQUARE FOOT TOTALS
z
00
0
THE h1FORMATION CONTAINEP ON TH15 SHEET "TI.2" 15
EXCLUSIVELY FOR PLANNINO ANP ZONINOREVIEVN4 IN T
( CURSE ♦ " BUILPIN6 PERMIT AND PLANNINO REVIEN
PROCESS ONLY"
FOR BUMBER PIERMW AND PLAN
REVIEW ONLY NOT FOR Chi NSTRUMON
In
m
lirk
SUITE 207
BOX 5300
AVON, CO 81620
970.949.5200
vmda@vmda.com
FAX 949.5205
@CO PYRII GHT
Victor Mark
Donaldson
Architects N
A r
All Rights
I
Reserved
0•
Z
uj
LLJ
(0
F-
F-
0
z
z
to
o
t
z
00
0
C)
MO
0
0
0
z
LLI
z
0
0
<
-j
w
0
<
040
-�
CL
>
w
UJ
coo)
>
@CO PYRII GHT
Victor Mark
Donaldson
Architects N
A r
All Rights
I
Reserved
le
EXISTINO CONCRETE L ANDING
(NO WORK TH15 AREA)
NSW ENTRY
STAIR WELL 5EC.710N
NEH CEDAR FASCIA (TYP)
NEW HOOP 51DINO AND COLOR TO
MATCH EX15TIN6 (TYP)
NEW "VEX-O-TEX" WATERPROOFING
SEE SECTION 01 / A6.1
-$ THIRD FLOO
112
NEW BALCONY H/ GUARD RAIL
PER 2005 150 SECTION 1012.2
AND 1601.1.1. HOOP BALUSTERS
AND RAIL AND C OLOR TO MATCH
EX15TIN0 BALCONIES
NEW HOOP 51PINO AND COLOR TO
MATCH EX15TINO (TYP)
-f$ SECOND FLOOR
103
NEW STUCCO FIN15H AND COLOR
TO MATCH EX15TIN(9
il
01001111
Rq
IL Ee
11
I
0
��I� ��1� i! '"�, li l I���I ,� I,� li f1l
M 11
i1 � �� I� j j� I i`.f 1 1L(�5 1 t � jj �[� j �_� -� I �� ° D
NEW RIDGE ROOF VENT N/
"CERTAINTEEP GRAND MANOR"
SLATE STYLE FISF-POLAS5
5HINOLE5 (TYP)
"CERTAINTEED GRAND MANOR"
SLATE STYLE 1`15EROLA55
5HINOLE5 (TYP)
NEW COPPER METAL FI-A5HIN6
WW ; 0 *OK
SEE DETAILS A&.I
NEW BALCONY W GUARD RAIL
PER 2003 113C SECTION 1012.2
AND 16071.1.1. HOOD BALUSTERS
AND RAIL AND COLOR TO MATCH
EX15TIN6 BALCONIES ---\
FIRST FLOOR
(NO HORK TH15 FLOOR)
EXCEPT AS NOTED ON FLOOR PLAN liI
jj
BASEMENT FLOOR
(NO WORK THIS FLOOR)
x--
t
FAR 9 1 1 111 0 PER MIT A
ME F A R 2111011
MA II I MIRM I I I WYA Nk' [MITI
In
w
ARCHITECTS
0 0 4 8 E BEAVER CREEK BLVD
SUITE 207
BOX 5300
AVON, CO 81620
97 0. 94 9 - 5201"
vmda@vmda.com
FAX 949.5205
•0
z
I
c
w
m
LLJ
co
F-
1--
z
2(o
u')
T
o
LAJ
-
-0
00
2
og
•
Z O
z
Lu
00
<
Lu
4�
<
0
CL
>
2w
w
0
co)
ca
g a °
d
r -
coi
u o
N00
ry E
ca 7� w
C �
4
0
Q ��
-- X
NEW RID(
"GERTAIh
SLATE S
SHINGLE°
"CERTAINI
SLATE 5T
SHINGLES
ROOF JOI
5TRUCTUR
"DUROVEN
AT EACH I
EXISTING
STONE HE,
DESIGNER
EXISTING I
EXISTING]
MEETS ALI
UL#U304
now 1-. 1
SCALE: I /4" = 1 "
R -30 UNFAGED BATT INSULATION
NEW "CERTIANTEED GRAND MANOR
SLATE STYLE FIBHERGLA55
5HINGLE5 (TYP) OVER FULL
COVERAGE UNDERLAYMENT H/
"GRACE ICE AND WATER SHIELD"
'DUROVENT " FOAM ATTIC
,/ENTILATION CHANNELS AT EACH
200F JOIST CAVITY (TYP)
ROOF J015T AND EXTERIOR
SHEATHING RE: STRUCTURAL
ROOF J015T GUT BACK TO RECEIVE
FASCIA / 5U5 FASCIA AS 5HOHN
CONTINUOUS COPPER DRIP EDGE
2x8 R.5, CEDAR FASCIA AND
=A5GIA
3" HIDE x CONTINUOUS VENT
COPPER HIRE MESH INSECT
'.EN PULLED TIGHT AND
ENED TO UNDER 51DE OF EACH
JOIST
3 /" T 4 G CEDAR SOFFIT
ROOF FASC,IA DETAIL
SCALE: I 1
ri
NEW RIDGE ROOF VENT VV/ "GERTAINTEED GRAND
MANOR" SLATE STYLE FIBERGLASS 5HIN6LE5
(TYP)
"GERTAINTEED GRAND MANOR" SLATE STYLE
FIBERGLASS SHINGLES (TYP)
ROOF J015T AND EXTERIOR SHEATHING RE:
STRUCTURAL HI "GRACE ICE AND HATER SHIELD"
"DUROVENT" FOAM ATTIC VENTILATION CHANNELS AT
EACH ROOF J015T CAVITY (TYP)
OPEN AT BALCONY
m
EXISTING SECOND FLOOR
103' -10"
NEW HAND RAIL PER 2003 IBC
SECTIONS 1001..11.1,1001.11.3, AND
1001..11.6
UNFAGED BATT INSULATION R -11
(TY P)
(2) LAYERS OF %" TYPE "X"
GYPSUM BOARD TO MATCH
EXISTING. UL # L541
NEW EXIT DOOR SEE DOOR
SCHEDULE SHEET All
EXISTING FIRST FLOOR
13' -6
2x12 STRINGERS AT BOTH
SIDES OF STAIRS
� y
q
F -
m
r
3" -O""
ENDING
MIN
EXISTING FIRST FLOOR LEVEL
(NO WORK THI5 AREA)
• W.
15 RISERS AT 10" EACH AND Al I" NOSING
EXISTING BASEMENT LEVEL
(NO HORK TH15 AREA)
EXCEPT AS NOTED ON FLOOR
.-h LONER FLOOR
(: SE(�TIO
S r
•
NOTE:
PER THE 2003 IBC SECTION 1203.2 ATTIC, VENTILATION AS FOLLOWS.
ENCL05ED ATTIC AND ENCLOSED RAFTER 5PACE5 FORMED HHERE CEILING IN APPLIED DIRECTLY TO THE UNDER 51DE OF THE ROOF
FRAMING MEMBERS SHALL HAVE OR055 VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENINGS PROTECTED AGAINST THE
ENTRANCE OD RAIN AND 5NOW. BLOCKING AND BRIDGING 5HALL BE ARRANGED 50 AS NOT TO INTERFERE HITH THE MOVEMENT OF AIR.
A MINIMUM OF INCH (25mm) OF AIRSPACE SHALL PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING, NET FREE VENTILATING
AREA SHALL NOT BE LESS THANyy OF THE AREA OF THE SPACE VENTILATED, HITH 50 PERCENT OF THE REQUIRED VENTILATING AREA
PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET (114mm) ABOVE PAVE
OR CORNICE VENTS HITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
NEW RIDGE ROOF VENT H/ "GERTAINTEED
GRAND MANOR" SLATE STYLE FIBERGLASS
SHINGLES (TYP)
"CERTAINTEED GRAND MANOR" SLATE STYLE
FIBERGLASS SHINGLES (TYP)
"ORACE ICE AND HATER SHIELD
2x2 R.5. CEDAR CONTINUOUS H/ CONTINUOUS
COPPER FLASHING. BOTH 510E5 (TYP)
2x8 TOE NAILED AT EACH ROOF
JOIST W EXTERIOR SHEATHING.
RE: STRUCTURAL (TYP)
NEW 3" HIDE COPPER HIRE MESH INSECT SCREEN PULLED
TIGHT TO THE END OF 2X8 AND FASTENED.
"PUROVENT " FORM ATTIC,
VENTILATION CHANNELS AT EACH
ROOF J015T CAVITY (TYP)
"
w
i ! j �i C R EE K !
i i 1 i l
SUITE 207
BO ! 1
AV ON , 1 8162
4 �
•s
•
0
r`
ul
.o
L
A
w
g
i
W
0
LAJ
4�
<
R
LLJ
4 �
2x6 FRAME WALL W/ UNFACED R -Iq
BATT INSULATIONA 5 /6" GYPSUM INTERIOR
EXTERIOR PLYWOOD SHEATHING
TO MATCH EXISTING RE: STRUCTURAL
EXTERIOR FINISHES RE: ELEVATIONS
CONTINUOUS COPPER FLASHING
"CERTAINTEED GRAND MANOR" SLATE
STYLE FIBERGLA55 51-1INGLE5 (TYP)
ROOF J015T AND SHEATHING RE:
STRUCTURAL
COR -A -VENT ROOF -2 -WALL VENT
5HIN61 E ROOF APPLICATION
1G LE
�7
ENHANCED 5NON SCREEN
"LAMARITE" SHAKE COMP051TE SHINGLE
BY "TAMKO ROOFING PRODUCTE5"
EXTERIOR SHEATHING RE: STRUCTURAL
"DUROVENT" FOAM ATTIC VENTILATION
CHANNELS (TYP)
WOOD LEDGER RE: STRUCTURAL
ROOF RAFTER RE: STRUCTURAL
NOTE: 1
PER THE 2003 IBC SECTION 1203.2 ATTIC VENTILATION AS FOLLOH5.
ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES FORMED WHERE CEILING IN APPLIED DIRECTLY TO THE UNDER SIDE OF THE ROOF
FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENINGS PROTECTED A6AIN5T THE
ENTRANCE OD RAIN AND SNOW. BLOCKING AND BRIDGING SHALL BE ARRANGED 50 AS NOT TO INTERFERE WITH THE MOVEMENT OF AIR.
A MINIMUM OF INCH (25mm) OF AIRSPACE SHALL PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING. NET FREE VENTILATING
AREA SHALL NOT BE LE55 THAN)(so OF THE AREA OF THE SPACE VENTILATED, WITH 50 PERCENT OF THE REQUIRED VENTILATING AREA
PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET N14mm) ABOVE EAVE
OR CORNICE VENT$ WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
ROOF / NALL VENT D ETA I L
Fixture Protection Cover: Constructed of a proprietary high - temperature fiber matrix and having FO4) I " ! V- 0"
an intumescent feature. Two sizes of covers are recognized within this Listing. The smaller cover
has a base diameter of 14 -1/2" and an overall height of 9" The larger cover has a base diameter of 17"
and an overall height of 11 -1/4" Covers are centered over openings up to 8 " in diameter that are cut
into the gypsum ceiling for the purpose of installing a recessed fixture. The cover may be slit to fit
over obstructions in order to allow the cover to fit flush to the gypsum wallboard. When this occurs,
caution is to be used to not damage the cover. The covers may be installed in the floor with the
following provisions:
• Max. 1 opening within 16 sq.ft. ceiling area
• Min. on center fixture spacing of 40" within same truss cavity.
• Min. center - to - center fixture spacing of 40 " for adjacent truss cavities.
• A min. 1/4" gap space must be maintained between the top of the cover and the underside
of the subfloor (1 A).
Recessed Fixture: (Not Shown) Installed in accordance with manufacturer's instructions. The fixture
can be installed in an opening having a max, diameter of 8" The fixture must be secured to the framing
of the floor, and may not be supported by the gypsum wallboard. Electrical wiring leading to and from
the fixture may penetrate the cover. When this occurs, caution is to be used to not damage the cover,
and the wiring is to fit snugly through any opening.
Testing Standard(s): ASTM -E119.
1-2115 M • • : :: �L�' SIT■
d d q
q
q d d d d
(2) LAYERS OF la" TYPE "X" GYPSUM BOARD TO MATCH
EXISTING. (TYP) UL # L541
NEW BEARING HALL RE: STRUCTURAL
a
EXISTING EXTERIOR WALL H/ PLYWOOD 5HEATHING. SEE
ELEVATIONS FOR FINISH MATERIALS
NEN CONCRETE TOPPING RE: STRUCTURAL
! f' NEW WARM BOARD AT NEW AND EXI5TING FLOOR AREAS RE:
q ---- STRUCTURAL
- NEW TGI TO MATCH EXISTING RE: STRUCTURAL
r NEW RIM J015T RE: STRUCTURAL
NEW EMERGENCY STAIR WELL
SE
FLOOR / C.,;EILINO ASSD�BL)"`
50ALE: 3" = 1' - O"
(THIS A55EMBLY AFF'LIE5 TO FLOOR / CEILING 5EPARATION
BETNEEN OCCUPANT 1 E5 "M" AND "R-2")
— NEW FRAME WALL N/ EXTERIOR GRADE PLYWOOD RE:
STRUCTURAL AND FIN15H MATERIALS. (5EE ELEVATIONS)
f ' NEW CONTINUOUS GALV CANT / FLA5HING
NEW EXTERIOR GRADE PLYHOOD RE: STRUCTURAL
NEW CONCRETE TOPPING RE: STRUCTURAL
NEW DEX -O -TEX WATERPROOFING 5Y5TEM CONSISTING Of
METAL LATH, A61 POLYMER MODIFIED CONCRETE, BARRIE
GUARD, RESI5TITE, AND TWO COATS OF POLYESTER URETI
SEALANT ALL SUPPLIED BY "DEX -O -TEX ". (SLIP COEFFICIE
TO BE 0.8 WET OR DRY) 5LOPE DEX -O -TEX il6" MIN PER
FOOT AWAY FROM BUILDING
SLOPE DECK I 16" PER 12"
d
d
.14 q a
a d' d .. .d q .q
a 4. .a
M1N 'd 4 O. d 4 a 1 b q
WOOD JOIST RE: STRUCTURAL
BUILDING 5TRUCTURE
RE: STRUCTURAL DRAHIN65
N1
NEN E3ALC.1ON" NATER
PROOFING DETAIL (T"�
5CALE: 3" = 1'- O"
NEW DOOR. RE: DOOR SCHEDULE SHEET A1.1
NEW WOOD OR STUCCO FINISH. RE: ELEVATIONS
NEW FRAME HALL N/ EXTERIOR GRADE PLYNOOD 5
5TRUCTURAL
NEW CONTINUOUS GALV THRESHOLD FLASHING
DOOR THRESHOLD TO COMPLY WITH THE 2003 IBC
SECTION 1005.1-b
NEW EXTERIOR GRADE PLYHOOD RE: STRUCTURAL
NEW DEX -O -TEX WATERPROOFING SYSTEM CON515TI1'
METAL LATH, A61 POLYMER MODIFIED CONCRETE, Bl
GUARD, RE515TITE, AND TWO COATS OF POLYESTER
SEALANT ALL SUPPLIED BY "DEX -O- TEX ". (SLIP COEI
TO BE 0.8 HET OR DRY) SLOPE VEX-O -TEX Il6" Mir
FOOT AWAY FROM BUILDING
SLOPE DECK Ilb" PER 12"
NEN BALC. NATER
PROOFING DETAIL (7'rP
5CALE: 3" = 1'- O"
E
i
I
I I
DEX -O -TEX WATERPROOFING SYSTEM CON515TINO OF
AL LATH, AV POLYMER MODIFIED CONCRETE, BARRIER
RD, RE515TITE, AND TH0 GOATS OF POLYESTER URETHANE
LANT ALL SUPPLIED BY "DEX -O -TEX ". (SLIP COEFFICIENT
3E 0.5 NET OR DRY) SLOPE DEX -O -TEX I /6" MIN PER
T AHAY FROM BUILDING
EW EXTERIOR GRADE PLYWOOD RE: 5TRUCTURAL
EW CONCRETE TOPPING RE" STRUCTURAL
ONTINUO COPPER METAL FLASHING
000 JOIST RE: STRUCTURAL
NEW BALCONY GUARD RAIL PER 2005 IBC SECTION 1012.2
AND 1607.7.1. WOOD BALUSTERS AND RAIL AND COLOR TO
MATCH EXISTING BALCONIES
NEN EXTERIOR GRADE PLYWOOD RE: STRUCTURAL
NEW DEX -O -TEX WATERPROOFING SYSTEM GONSI5TIN6 OF
METAL LATH, A81 POLYMER MODIFIED CONCRETE, BARRIER
GUARD, RE515TITE, AND TWO COATS OF POLYESTER URETHANE
SEALANT ALL SUPPLIED BY "DEX - TEX ". (SLIP COEFFICIENT
TO BE 0.6 WET OR DRY) SLOPE DEX -O -TEX 1i6" MIN PER
FOOT AWAY FROM BUILDING
NEW CONTINUOUS COPPER METAL FLASHING
W00D JOIST. RE: STRUCTURAL
WOOD JOIST RE. STRUCTURAL
Fri (� : IJILDER PERMIT AND PLAN
REUIEiN ONLY Nei T FA C�NSTR IJCTIaN
0
W
ARCHITECTS
t f � BEA C B LVD
SUITE 207
BO !
AV ON , 81
i 0 i t i 1 1
vmda@vmd
F 949 -5205
EXI5TING GYPSUM BOARD TO BE REPLACED
••
W/ (2) LAYERS OF %g" TYPE "X" MATCH NEW FLOOR CEILING
ASSEMBLY UL # L541 (FIRRE PROTECTION UNDER
I
i SEPARATE PERMIT)
THROUGH PENETRATION FIRE STOP AS PER
UL # F -0-2116 I HOUR
F -C -2111 (I HOUR RATING) AND F -C- 1023 (1 HOUR RATING)
tt4 V-
NOTE:
�-
L ALL CEILING / FLOOR THROUGH PENETRATIONS SHALL
COMPLY WITH 2003 IBC SECTIONS 112.4.1.1 AND 112.4.1.2
2. ALL EXI5TING FIRST FLOOR CEILING FIXTURES
(ELECTRICAL "J" BOXES, HIGH HAT LIGHT ETC) TO HAVE
"TENMAT FIRE COVERS, OR EQUAL, INSTALLED PER
MANUFACTURERS SPECS AND SEALED WITH "051" FLAME
SEAL CAULK.
4
00
0
�
1
EXISTING EXTERIOR WALL H/ PLYWOOD 5HEATHING. SEE
ELEVATIONS FOR FINISH MATERIALS
NEN CONCRETE TOPPING RE: STRUCTURAL
! f' NEW WARM BOARD AT NEW AND EXI5TING FLOOR AREAS RE:
q ---- STRUCTURAL
- NEW TGI TO MATCH EXISTING RE: STRUCTURAL
r NEW RIM J015T RE: STRUCTURAL
NEW EMERGENCY STAIR WELL
SE
FLOOR / C.,;EILINO ASSD�BL)"`
50ALE: 3" = 1' - O"
(THIS A55EMBLY AFF'LIE5 TO FLOOR / CEILING 5EPARATION
BETNEEN OCCUPANT 1 E5 "M" AND "R-2")
— NEW FRAME WALL N/ EXTERIOR GRADE PLYWOOD RE:
STRUCTURAL AND FIN15H MATERIALS. (5EE ELEVATIONS)
f ' NEW CONTINUOUS GALV CANT / FLA5HING
NEW EXTERIOR GRADE PLYHOOD RE: STRUCTURAL
NEW CONCRETE TOPPING RE: STRUCTURAL
NEW DEX -O -TEX WATERPROOFING 5Y5TEM CONSISTING Of
METAL LATH, A61 POLYMER MODIFIED CONCRETE, BARRIE
GUARD, RESI5TITE, AND TWO COATS OF POLYESTER URETI
SEALANT ALL SUPPLIED BY "DEX -O -TEX ". (SLIP COEFFICIE
TO BE 0.8 WET OR DRY) 5LOPE DEX -O -TEX il6" MIN PER
FOOT AWAY FROM BUILDING
SLOPE DECK I 16" PER 12"
d
d
.14 q a
a d' d .. .d q .q
a 4. .a
M1N 'd 4 O. d 4 a 1 b q
WOOD JOIST RE: STRUCTURAL
BUILDING 5TRUCTURE
RE: STRUCTURAL DRAHIN65
N1
NEN E3ALC.1ON" NATER
PROOFING DETAIL (T"�
5CALE: 3" = 1'- O"
NEW DOOR. RE: DOOR SCHEDULE SHEET A1.1
NEW WOOD OR STUCCO FINISH. RE: ELEVATIONS
NEW FRAME HALL N/ EXTERIOR GRADE PLYNOOD 5
5TRUCTURAL
NEW CONTINUOUS GALV THRESHOLD FLASHING
DOOR THRESHOLD TO COMPLY WITH THE 2003 IBC
SECTION 1005.1-b
NEW EXTERIOR GRADE PLYHOOD RE: STRUCTURAL
NEW DEX -O -TEX WATERPROOFING SYSTEM CON515TI1'
METAL LATH, A61 POLYMER MODIFIED CONCRETE, Bl
GUARD, RE515TITE, AND TWO COATS OF POLYESTER
SEALANT ALL SUPPLIED BY "DEX -O- TEX ". (SLIP COEI
TO BE 0.8 HET OR DRY) SLOPE VEX-O -TEX Il6" Mir
FOOT AWAY FROM BUILDING
SLOPE DECK Ilb" PER 12"
NEN BALC. NATER
PROOFING DETAIL (7'rP
5CALE: 3" = 1'- O"
E
i
I
I I
DEX -O -TEX WATERPROOFING SYSTEM CON515TINO OF
AL LATH, AV POLYMER MODIFIED CONCRETE, BARRIER
RD, RE515TITE, AND TH0 GOATS OF POLYESTER URETHANE
LANT ALL SUPPLIED BY "DEX -O -TEX ". (SLIP COEFFICIENT
3E 0.5 NET OR DRY) SLOPE DEX -O -TEX I /6" MIN PER
T AHAY FROM BUILDING
EW EXTERIOR GRADE PLYWOOD RE: 5TRUCTURAL
EW CONCRETE TOPPING RE" STRUCTURAL
ONTINUO COPPER METAL FLASHING
000 JOIST RE: STRUCTURAL
NEW BALCONY GUARD RAIL PER 2005 IBC SECTION 1012.2
AND 1607.7.1. WOOD BALUSTERS AND RAIL AND COLOR TO
MATCH EXISTING BALCONIES
NEN EXTERIOR GRADE PLYWOOD RE: STRUCTURAL
NEW DEX -O -TEX WATERPROOFING SYSTEM GONSI5TIN6 OF
METAL LATH, A81 POLYMER MODIFIED CONCRETE, BARRIER
GUARD, RE515TITE, AND TWO COATS OF POLYESTER URETHANE
SEALANT ALL SUPPLIED BY "DEX - TEX ". (SLIP COEFFICIENT
TO BE 0.6 WET OR DRY) SLOPE DEX -O -TEX 1i6" MIN PER
FOOT AWAY FROM BUILDING
NEW CONTINUOUS COPPER METAL FLASHING
W00D JOIST. RE: STRUCTURAL
WOOD JOIST RE. STRUCTURAL
Fri (� : IJILDER PERMIT AND PLAN
REUIEiN ONLY Nei T FA C�NSTR IJCTIaN
0
W
ARCHITECTS
t f � BEA C B LVD
SUITE 207
BO !
AV ON , 81
i 0 i t i 1 1
vmda@vmd
F 949 -5205
••
WZ
i n
�IIr
C#)
LO
M
00
0
�
1
a
W
i
i
.
i
LLJ
0
M
i
r
< �
<
0
i
i
BACKER ROD AND 5EALANT
ALUMINUM $ILL WITH THERMAL
ELA5HING
CONTINUOUS 2 1 /2 "A/8" PRi
ALUMINUM SILL EXTENSION.
GONTINUOU5 SEAL AND FAQ
U/5 OF THERMAL FLASHING
BACKER ROD d CONTINUOU5
5EALANT
CONTINUOUS COPPER FLA°
STUCCO OR WOOD 510INO
5ILL
05 CALE:
�
2x6" WOOD STUDS AT I6 " t
INTERIOR - 5/8" GYPSUM I
VAPOR BARRIER, R -11 P?
PAPER BACKED BATT IN51
EXTERIOR - 1/2" EXTERIOI
PLYWOOD. WRAP H/ TYVEI
WRAP AND HARDI BOARD
51PINO
HALL LINING RE: ROOM Flt
SCHEDULE
BACKER ROD AND 5EALAI
5TUCGO OR WOOD 51DING
CONTINUOUS BEAD CASINO
FOR STUCCO FIN15H
CONTINUOUS 2 "xl "xl /8" PRE
ALUMINUM ANGLE TERMINA'
PROVIDE CONTINUOUS SEA
CONNECTION WIRECEPTOR
THERMAL HEAD RECEPTOR
STUCC OR HOOD
WALL LINING RE: ROOM Fit
SCHEDULE
BACKER ROD AND 5EALAt
CONTINUOUS BEAD CA51N(5
2x6 " WOOD STUDS AT 16" t
INTERIOR - 5/8 " GYPSUM I
VAPOR BARRIER, R -Icl PA
PAPER BACKED BATT IN51.
EXTERIOR - 1/2" EXTERIOf
PLYWOOD. WRAP H/ TYVD
WRAP AND HARDI BOARD
51DING
CONTINUOUS 2 "xl "xl/8"' PRE!
ALUMINUM ANGLE TERMINA'
PROVIDE CONTINUOUS SEA
CONNECTION W/RECEPTOR
CONTINUOUS 1 1 /4 "xl 1/4 "1
PREF11415HED ALUMINUM FL)
ANGLE. PROVIDE CONTINUO
SEALANT 80TH FACES
JAME) DETAIL
5GALE: 3 " -1'-
FLOOR, WALL AND BASE FIN15H RE:
ROOM FIN15H SCHEDULE
ALUMINUM THRESHOLD (ANSI
COMPLIANT). PROVIDE CONTINUOUS
SEALANT BED TO LEADING EDGE AS
SHOWN
100 -0 , SLOPE RE: CIVIL
CAULKING AND COMPRE551BLE FILLER - - - -->
STRIP AT FLOOR/WALL JUNCTION
REIN, GONG. SLAB ON GRADE RE:
5TRUCT. ENG.
RE: PLAN ALI FOR EXTERIOR MATERIALS.
5GALE= 3 " :l' -0"
ALPINE SwwG
A Dtvislon of Vermont Slate & Gopper Services, Inc.
[SELECT DESIRED PIPE CONFIGUATION
❑ 2 PIPE HI -HOLE
1 PIPE (5HOWN)
❑ 5 PIPE
d5ELECT DE5IRED FINISH
❑ MILL (STANDARD)
❑ POWDER COAT
❑ KYNAR 500
ALPINE SN OV40UARD S
♦ +I M
05656
iii ) 1 66 - 4 2 -
ii a
PH ONE: iii ) 1(06-4
i /I rrr
FOR INSTALLATION PURPOSES SPECIFY:
BASE PLATE LENGTH
L
BASE PLATE WIDTH
W
❑ ANODIZED
❑I CUSTOM (CONTACT MANUFACTURER)
d5ELEGT DESIRED OPTIONAL ACCESSORY
❑ ICE FLAG
❑ END GAP5
❑ END GOLLAR5
❑ ICE SCREEN ,/— BOLT OR
/ 5CREW HOLE
HOLE FOR PIPE TO
BE FED THROUGH
5NOWOUARD
BRACKET
DOWN
SLOPE
SIDE VIEW
FRONT VIEW
N
I. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. 00 NOT SCALE DRAWIN55.
3. AVAILABLE IN ALUMINUM WITH A STAINLESS STEEL BASE PLATE. GONTACT MANUFACTURER
IF OTHER MATERIAL REO'D.
4. CONTACT MANUFACTURER FOR CUSTOM BASE PLATE5 TO MATCH LENG=TH AND WIDTH OF 5HINC -ALE.
5. CONTACT MANUFACTURER FOR DETAILED LAYOUT.
#125 BRACKET 4 BASE PLATE — FOR SLATE, 5HINGLE AND FLAT TILE ROOF APPLICATIONS
www.caddetails.com
FOR : 111 10. PERMIT AND PLAN
REUIEIN ONLY NOT FOR CONSTRUCTION
w
w
Cs
w
w
w
�c
NOTE: BASE PLATE AND FA57ENER5
MADE OF 5TAINLE55 STEEL.
ACCESSORIES INCLUDE 1" O.D.
ALUMINUM PIPE AND THREADED
COUPLING5.
02
wk-
SUITE
BOX 5300
181620
' 7 1 '4 9 5 2 11
! t i M !
F 1 4 !
ARCHITECTS
VARIES (SEE NOTE 4)
PLAN
••
•
..
z
CO)
.
•
T-
o
LLJ
2
00
0
i
0 d
0
W
a
LLJ
< �
<
Z>
W
LLJ
ARCHITECTS
VARIES (SEE NOTE 4)
PLAN
I1 -8"
Hfi HEIGHT
13 -0 -0
HEAD HEIGHT _
Ak HEAD HEIGHT
H EAD WEI GHT a' 4 "�_�
HEAD HEIGHT -__
61 -101. 1�
,L HEAD I�EIGWr
FIN FL ELEV____-
OIL HEAD HT
H� _
8' -O"
HEAD HT -
b
F __ I
f
FIN FL ELEV
Q
O . .0 1 1
01 - all
OIL LANDING EL
0' -O"
H EAD
l2' -I"
_ HEAD HT
\ q1 _ 011
3
N
FAMM
"qu
u
-- --
FIB N_ FL_ -EL EV _ �/y/ ___ M }y ------ -
�01- Q " I V' (( I f+
V'4
FIN
7 �1
NEW R00 IN IBH SSHSD�
ROOM
NO.
4
�
I
NORTH
t
SOUTH
j
GEILING
I
MATL
FIN
MATL
I
i.__- _.- .._.__l
MATL
FIN
-- -------- t
\ -
HT
201
KITCHEN
WD
WD
t
PTI
;
PTI
I
PTI
GWB
PTI
GWB
PT2
8' -0"
LIVING ROOM
D
202
DINING ROOM
WD
WD
GWB
PTI
12 -0
101
NMI
Lm
3 -0
I,1 -4 " 2 1_ 8 5!
" TYP -� TYP TYP
2' -Q" I . 1 21 -6
.4
1
21 -011 i' 2 -011 L' 21 -011 I' ,2 -011 L 5' - 0" �_.___
r.mW111111
A ,
2 1 - (y" 2- - 011
C G J J .G1/
` R C i 1 MM
2" -4'" 2' -8"
�Il TYP t 2"
2' -0"
TYP TYP
0
mmm
LOCATION
NEW R00 IN IBH SSHSD�
ROOM
NO.
4
�
I
NORTH
t
SOUTH
j
GEILING
I
MATL
FIN
MATL
FIN
------- --- _!
i.__- _.- .._.__l
0
mmm
LOCATION
A
NEW R00 IN IBH SSHSD�
ROOM
NO.
ROOM NAME
FLOOR
MATL
BASE
MAT'L
NORTH
EAST
SOUTH
WEST
GEILING
REMARKS
MATL
FIN
MATL
FIN
MAIL
FIN
MATL
FIN
MATL
FIN
HT
201
KITCHEN
WD
WD
GWB
PTI
G W B
PTI
GWB
PTI
GWB
PTI
GWB
PT2
8' -0"
LIVING ROOM
D
202
DINING ROOM
WD
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
8' -Q"
6' -4'
WD
203
P.R.
CTI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
8' -O"
G
I
204
BEDROOM #2
GI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
8 1 -0"
BI FOLD
VAR
205
BATH 205
CTI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
8' -O"
5' -6"
206
W.I.C.
GI
WD
GWB
PTI
GWB
PTI
GW B
PTI
GWB
PTI
GWB
PT2
MASTER BEDROOM
K
ALUM /CLAD WD
201
MASTER BATH
CTI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
P
GWB
PT2
4' -0"
WD
WD
208
MASTER BEDROOM
GI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
VARIES
SEE SHEET AII.I FOR CEILING HT'S
BEDROOM #2
20q
LIVING ROM
CI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
VARIES
SEE SHEET Al1.1 F CEIL H T'S
5 -4
300
BEDROOM #3
GI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
VARIES
SEE SHEE AI1. F CEI HT'S
Q
301
BATH ROOM
CTI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
P
b' -Q"
ALUM /GLAD WD
BI PA55
302
BATH ROOM
CTI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
G
PT2
1' -
WD
b' -O
303
HALL
GI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
VARIES
I BEDROOM #4
U
304
LAUNDRY
CTI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
8' -0"
305
BEDROOM #4
CI
WD
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PTI
GWB
PT2
VARIES
SEE SHEET AI1.2 FOR CEILING HT'S
LEGEND:
PTI PAINT I (PER OWNER) WD WOOD (PER OWNER) CTI CERAMIC TILE I (PER OWNER) GWB fe'" TYPE "X" GYPSUM WALL AND CEILING BOARD
CI CARPET I PER OWNS
NW ANA C) 0 0 R SCHE
YlINC�OW
FRAME
REMARKS
ELEV.
MATL
TYPE`.
WIDTH
HEIGHT
MATL
FIN.
HEAD WT.
A
3
KITCHEN
A
ALUM /CLAD WD
FX /GA
2' -0
3 - 0 "
WD
WD
6' -10"
B
4
LIVING ROOM
B
ALUM /GLAD WD
CA/FX/FX/CA
12' -0"
6' -4
WD
WD
b' -4
G
1
LIVING ROOM
G
ALUM /GLAD WD
FX
11 -8
4' -
WD
WD
13' -0
TRANSOM WINDOW SEE ELEVATION
D
1
LIVING ROOM
D
ALUM /GLAD NO
FX
2 "-
4' -b"
WD
WD
6' -O"
RADIUS TOP WINDOW SEE ELEVATION
E
I
LIVING ROOM
E
ALUM /GLAD WD
FX
2' -6"
6' -4'
WD
WD
b' -10
RADIUS TOP WINDOW SEE ELEVATION
F
I
LIVING ROOM
F
ALUM /GLAD WD
FX
5' -6
6 -4"
WD
WD
6 -10
RADIUS TOP WINDOW SEE ELE VATI O N
G
I
LIVING ROOM
G
ALUM /CLAD WD
AA/FX
VARIES
5' -4
WD
WD
12
TRAN50M WINDOWS SEE ELEVATIONS
H
I
LIVING ROOM
H
ALUM /CLAD WD
BI FOLD
VAR
6' -8"
WD
WD
6' -10
WEILAND BI FOLD DOOR SYSTEM
1
2
M. BEDROOM b EGRESS STAIR
I
ALUM /GLAD WD
FX
3 -0
4' -0
WD
WD
5' -6"
J
2
MASTER BEDROOM
J
ALUM /GLAD WD
GA
2' 4
4' -b"
WD
WD
8' -2
EGRESS WIDOWS
K
I
MASTER BEDROOM
K
ALUM /CLAD WD
FX
5' -O"
3 -1
WD
WD
12 -I"
RADIUS TOP TRAN50M WINDOW SEE ELEVATION
L
2
MASTER BATH
L
ALUM /GLAD WD
FX/AN
4' -0"
WD
WD
6-10"
TEMEPERED GLASS
M
I
BEDROOM #2
M
ALUM /GLAD WD
CA
2' -4"
5-0"
WD
WD
6-10" E6
RF55 WINDOW
N
3
BEDROOM #2
N
ALUM /CLAD WD
BI FOLD
?' -O"
5' - 0 "
WD
WD
6' -10"
O
1
STAIR WELL
O
ALUM /GLAD WD
FX
-
5 -4
WD
WD
5 -6
RADIUS TOP WINDOW SEE ELEVATION
P
I
STAIR WELL LANDING
P
ALUM /GLAD WD
FX
2' -O"
3' -O"
WD
WD
6' -10"
Q
1
BEDROOM #3
Q
ALUM /GLAD WD
BI FOLD
8' -0"
6' -8
WD
WD
6 -10"
WEILAND BNIFOLO DOOR SYSTEM
R
I
BEDROOM #4
R
ALUM /GLAD WD
BI PA55
5 -0
6' -8"
WD
WD
6 -10"
SLIDIN OL A 5 55 DOOR (EGRE55)
5
3
BEDROOM #4
5
ALUM /GLAD WD
GA/FX
2 -0"
4' -O"
WD
WD
b' -O
TEMPERED GLASS
T
I
STAIR WELL
T
ALUM /GLAD WD
FX
5 -4
8' -O"
WD
WD
5' -1"
RADIUS TOP WINDOW SEE ELEVATION
U
I I
I BEDROOM #4
U
ALUM /GLAD WD
FX
4' -0"
1 -8"'
I WD
WD
q' -0
RADIUS TOP TRANSOM WINDOW SEE ELEVATION
GENERAL NOTES: GENERAL NOTES GONTINUOUED:
WINDOW TYPE - ALL DIMENSIONS ARE FROM FACE OF FRAME TO FACE OF FRAME. WINDOWS SHALL BE DOUBLE PANE 'LOW E' AS RATED BY THE MANUFACTURER. WEATHER STRIPPING AND
AN AWNING - THE DIMENSION INDICATED FOR THE HEAD MOUNTING HEIGHT 15 TO THE TOP OF WINDOW FRAME. FLASHING AT WINDOWS SHALL BE TIGHT TO THE WEATHER AND MADE 50 AS NOT TO ALLOW LEAKAGE OR
GA CASEMENT - CONTRACTOR TO VERIFY ALL ROUGH OPENINGS 8 HEAD HTS W/ MFR PRIOR TO INSTALLATION. MOISTURE INTRUSION AT ANY JOINTS,
FX FIXED GLASS - SAFETY GLAZING SHALL BE PROVIDE IN ACCORDANCE WITH SECTION 2406 OF THE 2003 IRO. WINDOWS NOT SHOWN ON TH15 SCHEDULE ARE EXISTING AND ARE TO REMAIN
QTY. LOCATION DOOR FRAME HARDWARE REMARKS
FIRST FLOOR FROM TO WIDTH HEIGHT THICK MATL FIN TYPE GLAZING ELEV TYPE FIN HEAD HT, GROUP
100 1 4 PLAZA ENTRIES VARIES (SEE PLAN) 3' -O" 6' -8" 1 -3/4" 50 5T 5W - I WD ST 6 -10" #2
1 .
203 1 HALL P.R. 2' -4" b' -b" I -3/4" 50 5T POCK - 2 WD 5T
204 1 HALL BEDROOM #2 2' -b" b' -b" 13/4 5C 5T 5W - 3 WD 5T b' -10 #3
205 1 BEDROOM #2 BATH 205 2' -8" b' -b" 1.3/4 50 5T POCK - 4 WD 5T 6' -10" -
205.1 1 BATH 205 OL05ET b' - 2' - 4 " 1 3/4" SC 5T POCK - 2 WD WD 6-10" -
(5 �, } 205.2 1 BATH ROOM TUB/ 5HOWER ENGL05URE 5' -0" 4' -6 1/2" GLASS FACT BI -PA55 TEMPERED 6 ALUM FACT 6' -0"
' �-' 206 1 MASTER BATH W.I.G. 2 -0 b'-b" 1 -3/4 5C, 5T POCK - 5 WD 5T 6 -10"
2 01 1 MASTER BEDROOM MASTER BATH 3' - 0" 6-b" 1 -3/4" 5C 5T 5W - b WD 5T 6' -10 #3
207.1 1 MASTER BATH SHOWER 2 -0" 6 -0" 1/2" GLA55 FACT 5W TEMPERED q ALUM FACT 6-0 -
201.2 1 MASTER BATH W.G. AREA 2' -8" 6-8" 1 -3/4" 50 5T SW - 8 WD ST 6' -10 #3
2' -O" 208 1 LIVING ROOM MASTER BEDROOM 2' -8" 6' -8" 1 -3/4" 50/01- ST SW - 8 WD 5T 6 -10 11 #3
300 1 STAIR H ALL BEDROOM #3 2' -b" b' -8 1 3/4" 56 5T SW - 3 WD 5T 6' -10" #3
,I TYP% 301 1 BATH W.G. AREA 2 -4 6' -8 1 3/4" 5C 5T 5W - 1 WD 5T 6' - lo ll #3
2
301.1 1 W.G. AREA SHOWER 5 -0" 4' -6" 1/2" GLASS - BI PASS TEMPERED 6 ALUM FACT 6 -0 -
301.2 1 BAH CLOSET 5' -0" b' -b "" 1/2" MIRROR FACT BI PA55 - 10 WD 5T 6' -10" -
301.3 1 BATH ATTIC. STORAGE 2' -0" 5' -O" 1 3/4" SG 5T 5W - 15 WD 5T 5' -2" #1
302 1 BEDROOM #4 BATH 302 2 -4 b' -b" 1 3/4" 50 5T SW - 1 WD ST 6-10" #3
302.1 1 BATH 302 LINEN 1' -6 b' -b" 1 3/4" 5C, 5T 5W - 12 WD 5T 6 -10 -
302.2 1 BATH ROOM SHOWER 2' -0 " 6 -0 1/2" GLA55 FACT 13I - PA55 TEMPERED 6 ALUM FACT 6 1 -0 1, -
304 1 HA LAUNDRY 2 -5" 6' -b" 13/4" 50 5T 5W - 3 WD 5T 6' -10 #3
305 1 HALL BEDROOM #4 2' -0" 6' -b" 1 3/4" 5C. 5T POGK - 12 WD 5T 6-10" -
505.1 1 BEDROOM #4 CLOSET 2' -0 6' -8 13/4 5C. ST POCK - (I 5 WD 5T 6' -10" -
/� 306 1 EXTERIOR DECK MECHANICAL ROOM 3 -0" 3' -6 13/4" ALUM FACT 5W - 13 WD PT 4' -2" #2
301 1 LANDING ATTIC, STORAGE 2' -4" 5' -4" 1 3/4' 50 5T 5W - 14 WD ST 2' -b" #1
GROUP I DESIGNATION SIZE NOTES
HINGE MATCH EXISTING 4Y2 "X 4,1 1. ALL LOGKSETS TO MATCH EXISTING DOOR MATERIAL DOOR TYPE GENERAL NOTES
PASSAGE SET MATCH EXISTING 2. HINGES / PULL / PUSH PLATES TO MATCH EX15TINO 5C. SOLID GORE WOOD 5W SWINGING DOOR - CONFIRM KEYING CONFIGURATION WITH OWNER PRIOR TO INSTALLATION,
FINISH MATCH EXISTING 3. VERIFY ALL HARDWARE WITH DOOR HARDWARE REPRESENTATIVE WD WOOD POCK POCKET DOOR - ALL DOORS ARE TO BE INSTALLED SHALL MEET AN51 d ADA REQUIREMENTS.
4. PROVIDE I Y2 ALUM ALUMINUM GLAD " PAIR HINGES PER DOOR SL SLIDING
- MATCH EXISTING BUILDING STANDARI?5 WHERE APPLICABLE.
GROUP 2
DESIGNATION SIZE 5C. / GL SOLID CORE / FULL BI -FOLD - CONTRACTOR TO VERIFY ALL ROUGH OPENINGS s HEAD HT5 W/ MFR PRIOR TO INSTALLATION,
HINGE MATCH EX15TIN0 4 Y2 1 1 X 4)/2" BI -PA55 N
LOCKSET
MATCH EXISTING GLA55 LT MOUNT ALL DOOR ACCESS HARDWARE PER MFRS RECOMMENDED HEIGHTS.
FINISH MATCH EXISTING DOOR FI PANT WEATHER STRIPPING AND BE MIN.
BE TIGHT TO WEA HER BY THE MFR SET IN AND MADE 50 A5 BUIL STANDARD
ALLOW FRAME. FOR �► B U � L D E R P E H M � u A� � P ���
GROUP 3 DESIGNATION 51ZE 5T STAIN MOISTURE INTRUSION AT ANY JOINTS. � ONLY NOT ( (�} (� " ) :" T RU (� (�( (�
HINGE MATCH EXISTING 4 Y2'X 4)/211 FACT FACTORY FIN15H ti ALL DOORS NOT SHOWN IN TH15 SCHEDULE ARE EXISTING AND ARE TO REMAIN, UNLESS NOTED OTHERW ll� �/ � LA (�n(j (� ISE u W O (ICJ L �( N O (I FOR D 1 ' lu! N � !J D 1 U t�' tl [1 0 N
PRIVACY 5ET MATCH EXISTING
FIN15H MATCH EXISTING
0
Lill l
ARCHITECTS
! 1 '' ! BEAVER C l B LVD
SUITE 207
BO !
AV ON , ! 81620
vmd
FAX 949.5205
Lj r;
L 3 1-011 � Ll 21 - 5" � 21 -511 � 2' -311
•s
In
M
<
wc
i
0
< �
<
C`
#
2w
L 3 1-011 � Ll 21 - 5" � 21 -511 � 2' -311
N
0
N
L0
0
00
co
0
0
N
m
3
0
N
v
ti
Lo 'n
v
m
0
0
0
s
GENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
A. ROOF 8:12 80 PSF
B. TYPICAL FLOOR 40 PSF
C. EXTERIOR DECK 100 PSF
D. IMPORTANCE FACTORS
CATEGORY I
SEISMIC FACTOR IE 1
SNOW FACTOR IS 1
WIND FACTOR IW 1
E. WIND
3 SECOND GUST 90 MPH
FASTEST MILE 75 MPH
EXPOSURE B
F. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
G. CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2003 EDITION.
2. DEFERRED SUBMITTAL
A. DEFERRED SUBMITTALS PER SECTION 1063.4.1 SHALL BE SUBMITTED TO THE BUILDING
OFFICIAL AND THE DESIGN PROFESSIONALS AND REVIEWED PRIOR TO INSTALLATION.
B. DEFERRED SUBMITTALS ARE:
1. STEEL FRAMING MEMBERS
C. ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE
LICENSED PROFESSIONAL ENGINEER RESPONSIBLE FOR THE PREPARATION OF THESE
DOCUMENTS.
3. TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING MRK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. CONCRETE CONSTRUCTION
a. PERIODIC INSPECTION OF REINFORCING STEEL.
b PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.
c CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED
TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
d CONTINUOUS INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES.
e PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
2 STEEL CONSTRUCTION
a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTION
EXCEPT THE FOLLOWING:
1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN
ACCORDANCE WITH SECTION 1704.3.
b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT
DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,
WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE
VERIFIED PRIOR TO THE START OF MRK; PERIODIC INSPECTIONS ARE
MADE OF MRK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDS
IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP
WELDING.
1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE.
2 WELDED SHEET STEEL FOR COLD FORMED STEEL FRAMING
MEMBERS SUCH AS STUDS AND JOISTS.
3 WELDING OF STAIRS AND RAILING SYSTEMS.
c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS
AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.
d. PERIODIC INSPECTION OF THE STEEL FRAME TO VERIFY COMPLIANCE
WITH THE DETAILS SHOWN ON THE APPROVED CONSTRUCTION DOCUMENTS
SUCH AS BRACING, STIFFENING, MEMBER LOCATIONS AND PROPER APPLICATION
OF JOINT DETAILS AT EACH CONNECTION.
e. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND
MANUFACTURER'S CERTIFIED MILL TEST REPORTS.
f. PERIODIC VERIFICATION OF HIGH STRENGTH BOLTS, NUTS AND WASHERS
FOR CONFORMANCE TO ASTM STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFICATE OF
COMPLIANCE.
3 FOUNDATIONS
A THE ALLOWABLE SOIL BEARING PRESSURE ASSUMED IN DESIGN IS 3,000 PSF. THE
CONTRACTOR SHALL RETAIN A LICENSED SOILS ENGINEER TO INSPECT THE
FOUNDATION EXCAVATION. SOILS ENGINEER SHALL VERIFY IN WRITING THE ACTUAL
SOILS CAPACITY IS EQUAL TO OR GREATER THAN ASSUMED.
B. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARING
ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY
CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS
SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE.
C. ALL FOOTINGS ARE TO BE PLACED ON FIRM, UNDISTURBED, NATURAL SOIL, APPROVED
BY THE SOILS ENGINEER. IF SOFT SPOTS ARE ENCOUNTERED REMOVE SOIL AND
RECOMPACT WITH APPROVED FILL (RE: SOIL REPORT FOR DESCRIPTION OF BEARING
SOIL).
D. CENTER ALL FOOTINGS UNDER COLUMNS OR GRID LINES UNLESS NOTED OTHERWISE
ON PLANS.
E. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TESTS ON COMPACTED
FILL UNDER FOOTINGS AND INTERIOR SLABS-ON-GRADE.
F. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAY
BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.
G. FOR SOIL DRAINAGE REQUIREMENTS REFER TO SOILS REPORT AND CIVIL DRAWINGS.
5. CONCRETE
A. ALL CAST -IN -PLACE CONCRETE SHALL BE MADE WITH TYPE I /II PORTLAND CEMENT,
STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:
CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.
FOOTINGS 3000 psi STD - - - - - -
INTERIOR STRUCTURAL COLUMNS 4000 psi STD 0.50 - - -
EXTERIOR CONCRETE ( + +) 4500 psi STD 0.45 6 % -8%
+ + MAXIMUM SLUMP SHALL NOT EXCEED 4 ".
B. SLABS, TOPPING, FOOTINGS, AND COLUMNS SHALL NOT HAVE JOINTS IN A
HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF
SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE
SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE
ENGINEER.
C. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE
WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE
STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OF
CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.
A
7.
D. EXCEPT MERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL
CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11 - A
AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED
EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. MEN
LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM
LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM
AND SPAN.
E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS - D1.1.
F. MINIMUM WELDS TO BE PER AISC TABLE J2.4 BUT NOT LESS THAN 3/16 CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
G. FOR ALL BEAM /COLUMN OR BEAM /BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORT
SLOTS IN CONNECTION MEMBER ONLY (WT-SECTIONS, ANGLES OR SHEAR PLATES).
H. PROVIDE TEMPORARY BRACING AND PRECAUTIONS NECESSARY TO COMPLY WITH ALL
STEEL ERECTION STANDARDS AND TO WITHSTAND ALL CONSTRUCTION AND/OR
LATERAL LOADS UNTIL ALL FIELD CONNECTIONS ARE COMPLETED AND PERMANENT
LATERAL SYSTEMS AND DECKS ARE IN PLACE.
1. STEEL FABRICATOR SHALL NOT RECEIVE ADDITIONAL COMPENSATION FOR SHOP
DRAWING TIME FOR ANY REVISIONS TO ERECTION DRAWINGS NOR FOR ANY REVISIONS
TO PIECE DRAWINGS PRIOR TO ENGINEER'S APPROVAL OF ERECTION DRAWINGS.
8. LIGHT GAGE FRAMING
A. LIGHT-GAGE METAL FRAMING SHALL BE THE SIZE AND GAGE SHOWN ON THE
DRAWINGS.
B. FRAMING ROLLED FROM STEEL 18 GAGE AND LIGHTER SHALL CONFORM TO ASTM A570,
LATEST EDITION, WITH A MINIMUM YIELD STRESS OF 33,000 PSI.
C. FRAMING ROLLED FROM STEEL 16 GAGE AND HEAVIER SHALL CONFORM TO ASTM A570,
LATEST EDITION, WITH A MINIMUM YIELD STRESS OF 50,000 PSI.
D. ALL MRK SHALL CONFORM WITH THE RECOGNIZED STANDARDS AND CODES FOR
LIGHT GAGE METAL FRAMING.
9. NON-SHRINK GROUT
A. NON-SHRINK GROUT SHALL BE PROVIDED:
1. BETWEEN COLUMN BASES AND CONCRETE SUPPORTS.
2. BETWEEN BEAM BEARING PLATES AND CONCRETE SUPPORTS.
3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH
OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE.
10. MOD
A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI
2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 900 PSI
5" THICK - 5" AND WIDER NO. 1 Fb = 1350 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITVE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLEDIPPED OR BETTER).
C. TREATED SILL PLATE LUMBER MAY BE HEM-FIR, STRUCTURAL #1 GRADE.
D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X MOD JOISTS.
SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS
IS REQUIRED.
E. FASTEN ALL MOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304-9.1 UNLESS NOTED OTHERWISE.
F. LAMINATED BEAMS
1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH AT 12
PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL SIZES SHOWN
ARE NET.
2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCE
WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF
STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AiTC.
3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUS
MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS.
MEMBERS SHALL BE DESIGNED WITH ZERO CAMBER WITH TOP SURFACE
CLEARLY STAMPED ON EACH MEMBER.
G. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE.
3. FOR FLOORING USE 3/4" T &G STURD -I- FLOOR SHEATHING GLUED AND NAILED
WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
4. FOR ROOF USE 5/8" (40/20 SPAN RATING) EXPOSURE I SHEATHING NAILED
WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR
OSB SHEATHING NAILED WITH 8d (OR 10d) NAILS AT 6" ON CENTER ALONG PANEL
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
SHALL BE BLOCKED.
6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
H. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS AND
SHALL BE "BCI- JOIST" AS MANUFACTURED BY BOISE CORPORATION. ALTERNATES SHALL
BE REVIEWED BY THE ENGINEER. TO BE CONSIDERED, ALTERNATES SHALL HAVE A LOAD
CAPACITY IN BENDING, SHEAR AND DEFLECTION EQUAL TO OR GREATER THAN THE SIZE
SHOWN ON THE DRAWINGS. WEB BLOCKING AND BRIDGING TO BE AS REQUIRED BY THE
JOIST MANUFACTURER.
1. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS
CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI. BUILT UP
MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR
5 1/4" WIDE MEMBERS.
11. NON -STRUCTURAL ELEMENTS
A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
OTHER STRUCTURAL MOVEMENTS.
B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED UNLESS NOTED OTHERWISE.
REINFORCEMENT
A.
ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
A.
ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM
B.
VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND
A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE
ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND
DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60.
•
REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY.
B.
REINFORCEMENT PROTECTION UNLESS NOTED OTHERWISE:
C.
PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER
CD
1. CONCRETE POURED AGAINST EARTH 3"
ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS
r♦
2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH) 2"
AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON
�'
3. COLUMNS AND BEAMS (TIE BARS) 1-1 /2"
0
ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR
4. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3 /4"
i
SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF
ui
HIS ITEMS.
C.
REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH
SECTIONS 7.5, 7.6 AND 7.7 OF ACI 318, LATEST EDITION.
E.
SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL
STRUCTURAL STEEL. THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TO
D.
NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR
WRITTEN REVIEW OF SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE
AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL
CONTRACTOR.
BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER UNLESS NOTED
OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
E.
WATERPROOFING, VAPOR BARRIERS, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
STRUCTURAL
STEEL
F.
ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR
A.
ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS
WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE.
WHICH SHALL CONFORM TO ASTM 992, (50 KSl) AND EXCEPT PIPE COLUMNS WHICH
SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B, LATEST
G.
ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD AND
EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
ARCHITECTURAL DRAWINGS.
MISCELLANEOUS EMBEDDED ITEMS SHALL BE A36 STEEL.
H.
CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
B.
ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER.
CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307 UNLESS NOTED
OTHERWISE.
C.
STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
ON
ARCHITECTS
0 1 4 ! B EAVE R C B LVD
SUITE 207
B OX 5300
AV ON , l 81 620
' 7 1 9 4' 5 2 it
vmda@vmda.com
FAX 949,5205
Lu
•
•
•
CD
••
•
r♦
i
�'
•
0
i
ui
S
ti
v;
0
0D
OD
0
N
3
N
to
47
i
LO
r
m
0
Q ° ¢
I
S
NEW FLOOR SHEATHING
NEW FLOOR
JOISTS RE: PLAN
NEW 1 1/2" CONCRETE —
TOPP I NG
EXISTING FLOOR
FRAMING
. - A
UP ONLY
UP ONLY
51MPSON U
HANGERS
EXISTING RIM
M
fl
-1
L
118" VERSA -RIM
NEW 2X6 AT I' -4"
BEARING HALL
HITH GYPSUM
SHEATHING
Y
SUITE 207
BOX 5300
A VON , CO 8
0 11 l rr
vm da@vmda , co m
FAX 949.5205
UP ONLY i i
C@COPYRIGHT f _
Victor Mark.
Donaldson
Architects
i
NF L O� ��� \vke
�..
/15108 DID PRICING'
5/17/08 PERMIT
��
uj
05/12/2008
s M &N 7547
U7
PLAN
G
w
\.-` \`
LLJ
_
�
l A 0
TOP OF
Z
EXISTING '` S�N M
PLYHOOD
ALL EXISTING CONDITIONS SHALL
0
�� 0
BE VERIFIED ON SITE. DIFFERENCES
W
\�P
BETHEEN EXISTING AND NEW FRAMING
SHALL BE BROUGHT TO THE ATTENTION
��
r
00
OF THE DESIGN TEAM.
UJ
Z
O
w
�\.� WOOD EFRA ''C11�G NOTEv:
�
C�
O
m
0
STAN A \�� 1•
INDICATES BEAM 5UPPORTING HALL ABOVE.
Z
Q
STE G LU pN 2.
"L.V.L." INDICATES VER5A -LAM BEAMS, AS MANUFACTURED BY E3015E
?z
u
CASCADE CORPORATION. ALTERNATES SHALL HAVE THE SAME OR
�.
GREATER CAPACITY AS LISTED IN THE STRUCTURAL GENERAL
NOTES.
UJ
-�-�
-}�Q 5.
❑ INDICATES COLUMN DOHN ONLY- MULTIPLE 2X FRAMING NOTED
ON PLANS.
4.
0 INDICATES COLUMN UP AND DOHN UNLE55 IT BEAR-5 ON
._..I
EXISTING
CONCRETE HALL OR FOOTING BELOW, OR IT 15 LABELED UP ONLY.
FLOOR
5.
< > INDICATES TOP OF BEAM ELEVATION.
JOISTS
THIS NOTE DOES NOT APPLY TO ROOF BEAM. (RE: ROOF NOTES.)
J
6.
�—' INDICATES TOP OF STRUCTURAL FLOOR SHEATHING
XISTING BEA
-!.
HEADERS SHALL BE (3) -2X8 UNLESS NOTED OTHERWISE. ALL
rE
HEADERS SHALL BE BUILT OUT TO 51/2" (51/2") HIDTH BY
ADDING PLYH00D SPACERS AS REQUIRED.
UP ONLY UP ONLY 8.
ALL COLUMNS SHALL BE (5) -2X6 UNLESS NOTED OTHERHI5E.
cf. HOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR
TO FLOOR OR FLOOR TO ROOF. TRIMMERS SHALL BE ADDED TO
NOTED COLUMN SIZES AS REQUIRED.
10, INDICATES INTERIOR BEARING HALLS. FLOOR JOISTS
BEARING LOCATIONS SHALL LINE UP HITH STUDS BELOH.
11. ALL EXTERIOR HALLS SHALL BE CONSTRUCTED U51NG 2X6
5TUD5. REFER TO EXTERIOR HALL DETAILS FOR
ADDITIONAL INFORMATION.
EXTERIOR STUDS CAN BE 5PACED 2' -0" FOR HALLS SHORTER
THAN 10' -0 ". STUDS SHALL BE SPACED P -4" FOR HALL SHORTER
THAN 14' -0" AND TALLER THAN 10' -0"
12. ALL BEAM/BEAM AND BEAM /COLUMN CONNECTIONS SHALL BE
MADE WITH 5IMP5ON STEEL PLATE CONNECTORS UNLESS NOTED
OTHERHI5E.
15. RE: ARCHITECTURAL DRAHIN65 FOR LOCATION AND 51ZE OF
ROUGH OPENING5 IN HOOD STUD HALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR
FRAMING DETAILS.
15. ALL EXTERIOR HALLS SHALL HAVE CONTINUOUS STUDS FROM
FLOOR TO FLOOR OR FLOOR TO ROOF (INCLUDING RAKE HALLS).
[N MAIN LEVEL �RAI"IINCz PLAN
C@COPYRIGHT f _
Victor Mark.
Donaldson
Architects
All Rights
Reserved Y
/15108 DID PRICING'
5/17/08 PERMIT
1
05/12/2008
s M &N 7547
MAIN LEVEL FRAMING
PLAN
G
w
v
�_tl
1
f. d.
FAX 949,5205
w
a
a
0
co
m
0
a
N
t!?
Cfl
fV
A
N
h
i
<t
i
m
0
0
U
R
ALL EXISTING CONDITIONS SHALL
BE VERIFIED ON SITE. DIFFERENCES
BETWEEN FX15TINO AND NEW FRAMING
SHALL BE BROUGHT TO THE ATTENTION
OF THE DE51ON TEAM.
WOOD FRA"ING NOTES:
INDICATES BEAM SUPPORTING WALL ABOVE.
2. "L.V.L." INDICATES VERSA -LAM BEAMS, AS MANUFACTURED BY BOISE
CASCADE CORPORATION. ALTERNATES SHALL HAVE THE SAME OR
GREATER CAPACITY AS LISTED IN THE STRUCTURAL GENERAL
NOTES.
S. ❑ INDICATES COLUMN DOWN ONLY- MULTIPLE 2X FRAMING NOTED
ON PLANS.
4. 0 INDICATES COLUMN UP AND DOHN UNLE55 IT BEARS ON
CONCRETE HALL OR FOOTING BELOW, OR IT IS LABELED UP ONLY.
5. < > INDICATES TOP OF BEAM ELEVATION.
TH15 NOTE DOES NOT APPLY TO ROOF BEAM. (RE: ROOF NOTES)
6. 0 INDICATES TOP OF STRUCTURAL FLOOR SHEATHING
ELEVATION.
`I. HEADER5 SHALL BE (3) -2X8 UNLESS NOTED OTHERHI5E. ALL
HEADERS SHALL BE BUILT OUT TO 5 1/2" (S 1/2 ") HIDTH BY
ADDING PLYHOOD SPACERS AS REG2U I RED.
8. ALL COLUMNS SHALL BE (3) -2X6 UNLESS NOTED OTHERHI5E.
q. HOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR
TO FLOOR OR FLOOR TO ROOF. TRIMMERS SHALL BE ADDED TO
NOTED COLUMN SIZES AS REG2UIRED.
10. INDICATES INTERIOR BEARING HALLS. FLOOR JOISTS
BEARING LOCATIONS SHALL LINE UP HITH STUDS BELOW.
11. ALL EXTERIOR HALLS SHALL BE CONSTRUCTED USING 2X6
STUDS. REFER TO EXTERIOR HALL DETAILS FOR
ADDITIONAL INFORMATION.
EXTERIOR STUDS CAN BE SPACED 2' -0" FOR HALLS SHORTER
THAN 10' -0 ". STUDS SHALL BE SPACED 1' -4" FOR HALL SHORTER
THAN 14' -0" AND TALLER THAN 10' -0 ".
12. ALL BEAM/BEAM AND BEAM /COLUMN CONNECTIONS SHALL BE
MADE WITH 51MP50N STEEL PLATE CONNECTORS UNLESS NOTED
OTHERHISE.
15. RE: ARCHITECTURAL DRAHIN05 FOR LOCATION AND SIZE OF
ROUGH OPENINGS IN HOOD STUD HALLS.
14. RE: ARCHITECTURAL DRANIN05 FOR HANDRAIL AND STAIR
FRAMING DETAILS.
15. ALL EXTERIOR HALLS SHALL HAVE CONTINUOUS STUDS FROM
FLOOR TO FLOOR OR FLOOR TO ROOF (INCLUDING RAKE HALLS).
6TEEL FRAMING NOTE&:
(XXX' -XX ") INDICATES TOP OF STEEL BEAM ELEVATION
2. ❑ INDICATES TUBE STEEL COLUMN (HHERE LABELED T5) DOHN ONLY.
5. 0 INDICATES TUBE STEEL COLUMN (WHERE LABELED T5) UP AND DOHN, UNLESS IT 15
LABELED UP ONLY.
4. � -- -- INDICATES TOP OF PLYWOOD ELEVATION.
UPPED LEVEL F2AMING- PLAN
1/4" = 1' -0"
ARCHITECTS
ui
�►
i
aoo)
•
�
•o
i
••
0
t
ARCHITECTS
0
m
ov" 2.2
'fib Il t 1
vm da@vmda.co m
F AX t, 9 0
a°' �'' � a
M
�_.J
C
Q
M
W
co
0
0
N
M
N
ttT
V
m
0
I
GC
NEI
AT
41-1. EXISTING CONDITIONS SHALL
3E VERIFIED ON SITE. DIFFERENGE5
3ETHEEN EXISTING AND NEW FRAMING
SHALL BE BROUGHT TO THE ATTENTION
aF THE DESIGN TEAM.
) OF FfR,4I G NC ! E6
ROOF 5HEATHIN0 5 1a " (40/20 SPAN RATING). 5TA00ER PANEL END JOINTS
, NND FASTEN WITH IOd NAILS AT b" MAXIMUM ALL EDGE5 AND 1' -0" MAXIMUM
DTHER SUPPORTS.
RE: ARCHITECT FOR ROOF SLOPES AND BEARI PLATE HE I GHT5
'10T NOTED.
ALL HEADERS SHALL BE (3) -2XIO UNLE55 OTHERWISE NOTED. ALL
rfEADERS SHALL BE BUILT OUT TO 5 1/2" OR 5 1/2" WIDTH BY ADDING
PLYWOOD SHIMS AS REQUIRED.
oNLL HEADERS LONGER, THAN &' -0" SHALL REG2UIRE TWO TRIM
5TUD5 AND TWO KING STUDS EACH SIDE.
Al L JOIST HANGER5 SHALL BE SIMPSON LUP, WP OR L55U TYPE
JNLE55 OTHERWISE NOTED.
ALL BEAM TO COLUMN CONNECTIONS, BOTH TOP AND BOTTOM
5HALL USE 51MP50N PLATE CONNECTORS UNLESS NOTED
OTHERWISE ON DETAILS.
ALL EXTERIOR WALLS SHALL HAVE CONTINUOUS STUDS FROM
FLOOR TO ROOF (INCLUDING RAKE WALLS).
a. < > INDICATES BOTTOM OF PLYWOOD 5HEATHING AT GENTERLINE OF ROOF BEAM.
TH15 NOTE DOES NOT APPLY TO FLOOR FRAMING. (RE: FLOOR FRAMING NOTES)
q. RE: ARCHITECT FOR CHIMNEY SIZES AND LOCATIONS NOT NOTED
ON STRUCTURAL PLANS.
10. ALL COLUMNS SHALL BE (3) -2X& UNLE55 OTHERWISE NOTED.
11. ALL ROOF FRAMING JOISTS SHALL BE 2X12, DOUGLA5 FIR,
STRUCTURAL #2 GRADE OR BETTER JOISTS. UNLESS NOTED OTERHI5E.
12. ALL HEAVY TIMBER BEAMS SHALL BE DOUOLA5 FIR LARCH GRADE NO. I.
ROOF =RA1` iINCz PLAN
Lu
i
r
i
i
0
a
�R
c
`►
C)<>
>
C
sk
@COPYRIGHT
Victor Mark
Donaldson „
Architects
All Rights f;
Reserved
NOR
k /15108 DD & PRICIN
5/12/08 PERMIT
r
05/12/2008
f
M &N 7547
ROOF FRAMING FLAN
2 . 3
t' �,�
9
m
00
co
N
cfl
3
M
t!i
V'
L0
ti
W
ca
0
EXTERIOR STUD -
WALL WITH
SHEATH I NO
5/4" PLYWOOD —
FLOOR SHEATHING
METAL STUD
JOISTS RE: PLAN
WITH SIMP50N
5/6 HANGERS
5 1/2 " -3" CONCRETE
TOPPING WITH 6X6
W2.1 X W2.1 W.W.F.
WATERPROOF I NO
RE: ARCH
PLYWOOD DECK
SHEATH I NO
SLOPE
�r a j x�
X
STEEL BEAM —
RE: PLAN WITH
(2) -2X8 TOP
PLATES WITH
1/2"0 BOLTS
AT 2' -0"
2X SOLID WEB -
PACK WITH 1 /2 "fi
BOLTS AT P -O"
eE T f N 4.
1 1/2" = 1' -
eEC TION e�.
1 1/2" = 1' -0"
EXTERIOR STUD -
WALL WITH
SHEATH I NO
5/4 " PLYWOOD —
FLOOR 5HEATHIN0
METAL STUD
JOISTS RE: PLAN
WITH 51MP50N
5/B HANGERS
LVL DECK JOISTS
WITH SIMPSON HU
HANOER5
' " -3" CONCRETE
ING WITH 6X6
W2.1 W.W.F.
RPROOF 1 NO
,RCH
OOP DECK
TH I NO
BECK JOISTS
'LAN
VERSA RIM
RIOR STUD WALL
SHEATHING
5 1/2 " -3" CONCRETE
TOPPI NO WITH 6X6
1^12.1 X W2.1 W.W.F.
WATERPROOFINO
RE: ARCH
PLYWOOD DECK
5HEATHINO
SLOPE
d .
a �X A
5TEEL BEAM —
RE: PLAN WITH
(2) -2X8 TOP
PLATES WITH
1/2 "4> BOLTS
AT 2' -0"
2X 50LID WEB -
PACK WITH 1/2 "4>
BOLTS AT 1' -0"
EXTERIOR STUD
WALL WITH
SHEATHING WITH
TRIPLE BOTTOM
PLATE
2X SOLID WEB -
PACK WITH 1/2 "4>
BOLTS AT I "-O"
STEEL BEAM `
RE: PLAN WITH
1/2 "4> BOLTS
AT I' -O " THROUGH
PLYWOOD AND WALL
BOTTOM PLATE
&E T I ON - 1-
1 1/2" = I "-O"
LVL DECK JOISTS
WITH SIMPSON HU
HANOER5
1 5/4" X q 1/2" LVL
LEDOER WITH (2) -ROWS
IOd NAILS AT 6"
5 1/2 " -3" CONCRETE
TOPPINO WITH 6X6
1-42.1 X W2.1 W.W.F.
WATERPROOFING
RE: ARCH
PLYWOOD DECK
5HEATHINO
LVL DECK JOISTS
RE: PLAN WITH
51MP50N HU HANOER5
EX15TINO 4 "4>
STEEL COLUMN
NEW PLYWOOD FLOOR
SHEATHING; GLUE AND
RAM5ET WITH HILTI
EDSDX76 POWDER
ACTUATED FASTENERS
AT I '-O" ON CENTER
AT BEAMS
A1
R*
IF*
NEW STEEL BEAM
RE: PLAN
3/8 " X 5 1/2" X 6"
STEEL PLATE EACH
SIDE OF BEAM WITH
(2)- 5/4 "4> BOLTS
(A525)
318" X 5 1/2" X 6"
STEEL PLATE EACH
SIDE OF BEAM WITH
(2)- 3/4 "4> BOLTS
(A525)
SECTION ,4_,4
DOUBLE 8" IS OAOE
CSX STUD JOISTS
5/4" PLYWOOD
FLOOR 5HEATHINO
OLUE TO JOISTS AND
5TEEL BEAM AND
RAM5ET TO STEEL
BEAM WITH HILTI
ED5DX76 AT P -O"
8 OAOE SELF TOPPINO
50REW5 AT 6" ALONO
PANEL EDOES AND
I "-O" ON CENTER IN
FIELD; TYPICAL
SIMPSON S/B `
HANGER AT STEEL BEAM
EACH JOIST RE: PLAN
&EC, 2-
1 1/2" = 1' - 0 "
DECK FINISH
RE: ARCH
BLOCK I NO
WATERPROOF
MEMBRANE -
S /4" PLYWOOD
PECK----\\ FLOOR 5HEATHINO
5HEATHINO
DECK JOIST
RE: PLAN
METAL STUD FLOOR
JOIST WITH VERSA -LAM
E M BEAM
I OUTRIOGER. WITH 5/4 "4>
P
RLAN
RE: : PLAN
THRU -BOLTS AT 1' -0 ";
RIP VERSA -LAM TO 4"
EXTERIOR STUD WALL
AT EXTERIOR
WITH SHEATHING
_
�-
i
&E(�TION I-
1 1/2" = 1' -0"
0
Call
ARCHITECTS
0! 4 1 BEA C B LVD
B O X SUITE 207
AVON C O 8162
vmd
FAX 949.5205
A� 4
ilia .
@COPYRIGHT
Victor Mark
Donaldson
Architects
All Rights
Reserved
r
R ����� 11510$ DD & PRICIN
511210$ PERMIT
4T x 05/12/2008
...
s M &N 7547
FRAMING DETAILS
�S3.1
eE T 1 ON
1 1/2" = 1' -011
i
r
!
0!
9%
�►
••
i
Lu
Z
�►
uj
@COPYRIGHT
Victor Mark
Donaldson
Architects
All Rights
Reserved
r
R ����� 11510$ DD & PRICIN
511210$ PERMIT
4T x 05/12/2008
...
s M &N 7547
FRAMING DETAILS
�S3.1
eE T 1 ON
1 1/2" = 1' -011
1 114
0
00
00
<D
C)
T�
N
V)
ti
Nr
Lo
r
'T
to
NEW ROOF
SHEATHING ROOF SHEATHING
\/ER5A-LAM RIDGE
NEW ROOF BEAM RE; PLAN ROOF JOIST RE: PLAN
JOISTS WITH CONTINUOUS
RE- PLAN BEVELED PLATE
1/4" STEEL PLATE
BEAM SEAT WITH
1 1 4 X 4 X 10' STEEL
5IMP50N 51DE PLATE WITH L55U HANGER 5/4"4> X 4" LAO
� �E� 12 BOLT
K
X a"
X 31 LAG BOLTS a
LAO -BOLTS
PIP
SIM
h�
------ - - - - --
1 1/2
1 1/2
1 1/2 FULL 1 1/2" PEN
1/4" STEEL PLATE NEW OL RIDGE
5 1/2 BEAM SEAT WITH BEAM RE; PLAN
NEW OL RIDOE 5/8 "4> THRU BOLT
BEAM RE: PLAN
BENT H558X4X518
EX15TINO OL BEAM
RIDOE BEAM
5ECTIOld E�- &ECTION I
5/4 = 1
NEH ROOF
SHEATH INO
NEW ROOF
JO1STS
RE: PLAN
EX15TINO ROOF
5HEATHINO
EX15TINO ROOF
'JO15T5
LI 1/2
3 1/2
NEW OL RIDOE-
BEAM RE: PLAN
5/4 = 1' -O"
1/4 STEEL PLATE
BEAM SEAT HITH
5/8 "4> THRU BOLT
—EXISTING OL
RIDOE BEAM
x 5
LAO BOLTS
Ins
NEH OL RIDOE
BEAM RE: PLAN
5/4 = 11-011
L&HRAr
(5)-12
5ECTION =I-
5/4 = 11-011
3/4" = 1 1 - 0 11
NEW (3)-12" \/L
RIP015- BEAM
-4FATHINO
�15T5
= BEAM R E. , P —
NEW ROOF J015T5
RE: PLAN
WITH SIMPSON
L55UHANOER5
NEW ROOF
5HEATHIN0
NEW SIMPSON
A55 CLIP
TWO 51PE5
5 1/&" X 5 ]/&" &L
COLUMN
5/4 = 11-011
1-1
NEW EXTERIOR
BEARING STUD HALL
HITH PLYHOOD
5HEATHINe
� Z
Nw-1
NEH EXTERIOR
BEARINO STUD
HITH PLYH000
SHEATHING
E CTION 3.
5/4 = 11-01.
NEW
FASCIA
NEH 5/4" T40 SOFFIT
HITH 5" CONTINUOUS
VENT
NEW EXTERIOR
STUD HALL HITH
HEADER BEAM
EX15TINO &L BEAM
NEW 1/4" KERFED
STEEL T-PLATE
WITH (2)-1/2"4> X 4"
LAO BOLTS IN
BEAM AND 1/2"4>
THRU BOLTS IN
COLUMN
SECTION 4.
5/4 = 1#-011
ROOF 'JOISTS
PLAN
BLOCKING
ROOF 5HEATHINO
(2)-2X8 FASCIA
5/4" T$ 0 SO FFIT
WITH 5" CONTINUOUS
VENT
EXISTING ROOF
SHEATHING
EXISTINO ROOF
J015TS
NEH VL BEAM
RE: PLAN
ROOF 'JO15T5
PLAN
BL OCK
ROOF 5HFATHIN0
(2)-2X8 FASCIA
5/4" T40 SOFFIT
4 5" CONTINUOUS
T
NEH BLOCKING
NEH ROOF SHEATHINO
NEH LADDER FRAMINO
RE: PLAN
5IMP50N U
HANOER5
NEW DORMER
IJOISTS
"
Diff
ARCHITECTS
0! 4 8 E BEAVER CREEK BLVD
SUITE 207
BOX 5300
AVON, CO 81620
9709
vmda@vmda.com
FAX 9495205
..Ilia
Lu
co
LU
•
Lu
000
K-
0
0
0
<
0
LUZ
-j
g:
z
0
LLJ
0
<
. . . . . . . . . . . . . .
@COPYRIGHT
Victor Mark
Donaldson
Architects
All Rights
Reserved
������ 115 /08 DID & PRICING
fi
5/12/08 PERMIT
[�;�'� 05112/20081
�(j�0 7x M&N 7547
FRAMING DETAILS
�� �d 'Ne
.............. I
S3.2
ISSUE / REVISIONS:
4 -15-08 DD / PRELIMINARY PRICING SET
5 -5-08 95% CD REVIEW SET
5 -1 6-08 PERMIT SET
MECHANICAL LEGEND
( NOT ALL SYMBOLS LISTED BELOW ARE BEING USED IN THIS SET OF MECHANICAL DRAWINGS )
I I RETURN DUCT
DOWN
Ilf� DUCT DROP
L
ABBR
t
Ml-
EXHAUST DUCT
DOWN
+-- --(1 L)-
, 4
DUCT W INTERNAL
LINING 1L= 1" THICK
2L= 2" THICK
■
• •• r i
t
=®
GALLONS PER
TRAN - T.
ROUND DUCT
DOWN
GRILLE
--�
T ROUND
LOW PRESSURE
ROUND DUCT
UP
Ilf� DUCT DROP
L
ABBR
t
Ml-
(1 L)
+-- --(1 L)-
, 4
DUCT W INTERNAL
LINING 1L= 1" THICK
2L= 2" THICK
■
• •• r i
t
=®
GALLONS PER
TRAN - T.
T
GRILLE
--�
T ROUND
VANED ELBOW
CAPPED
DUCTWORK
- - -- EXISTING
-- - - - - -- DUCTWORK NO
CHANGE
V
ABBR
t
EXISTING
DUCTWORK TO
BE REMOVED
(1 L)
+-- --(1 L)-
, 4
DUCT W INTERNAL
LINING 1L= 1" THICK
2L= 2" THICK
�TT
ABBR
t
FIRE DAMPER
MCC
■
, 4
-
-r
(CONICAL TAP
•
...... ♦ • r • .`
ABBR
SUPPLY SLOT
•
LU(;&ffW-
, QUADRA NT
MCC
■
, 4
-
-r
■
■
t
MOTORIZED
DAMPER
GALLONS PER
PROTECTION
SUPPLY DIFFUSER -
GRILLE
(CONICAL TAP
•
...... ♦ • r • .`
ABBR
SUPPLY SLOT
•
LU(;&ffW-
, QUADRA NT
MCC
■
, 4
-
-r
III
I BA CK DRA FT
r • - -
(CONICAL TAP
•
...... ♦ • r • .`
Ef' I
ABBR
SUPPLY SLOT
►
MCC
SUPPLY DIFFUSER -
, 4
(E)
4 -WAY THROW
���
RETURN AIR
EXISTING PIPING
GALLONS PER
PROTECTION
SUPPLY DIFFUSER -
GRILLE
--�
3 -WAY THROW
LOW PRESSURE
PRE - FILTER
(PNEUMATIC)
�I►
®
SUPPLY DIFFUSER-
CEILING ACCESS
L/D
2-WAY THROW
PANEL
BF
SUPPLY DIFFUSER -
HUMIDIFIER
BO
1 -WAY THROW
Ef' I
ABBR
SUPPLY SLOT
PIPING:
MCC
DIFFUSER
-- (E) --
(E)
EXISTING PIPING
���
RETURN AIR
EXISTING PIPING
GALLONS PER
PROTECTION
RA
GRILLE
--�
CONTROL AIR
LOW PRESSURE
PRE - FILTER
(PNEUMATIC)
FLEXIBLE DUCT
®
AP
CEILING ACCESS
L/D
DOWN
PANEL
BF
BOILER FEED
HUMIDIFIER
BO
BLOW OFF
CF
FLEXIBLE DUCT
CHEMICAL FEEDER
— PCs. —.
PCS
CONNECTION
SYMBOL
ABBR
DESCRIPTION
PIPING:
MCC
GAL
-- (E) --
(E)
EXISTING PIPING
���
•
EXISTING PIPING
GALLONS PER
PROTECTION
TO BE REMOVED
p
p
CONTROL AIR
GRAVITY VENTILATOR,
PRE - FILTER
(PNEUMATIC)
BD
BD
BOILER BLOW
HEATING C01L
L/D
DOWN
BF
BF
BOILER FEED
BO—
BO
BLOW OFF
CF
CF
CHEMICAL FEEDER
— PCs. —.
PCS
PROCESS COOLING
11
RPM
WATER SUPPLY
•—PCR —
PCR
PROCESS COOLING
(R)
REMOVE OR
WATER RETURN
—HWS—
HWS
HEATING WATER
(E)
EXISTING (PAREN-
SUPPLY
—HWR—
HWR
HEATING WATER
T
ITEM INDICATES
RETURN
—HTWS—
HTWS
HIGH TEMP. HOT
► �f
NEW
WATER SUPPLY
—HTWR—
HTWR
HIGH TEMP. HOT
=A
ABOVE FIN. FLOOR
WATER RETURN
—CHS —
CHS
CHILLED WATER
TOD
TOP OF DUCT (AFF)
SUPPLY
— CHR —
CHR
CHILLED WATER
TOP
V
RETURN
—CWS
CWS
CONDENSER
AF
AUT
WATER SUPPLY
—CWR
CWR
CONDENSER
WET -BULB
FLOOR
WATER RETURN
LPS
LPS
LOW PRESSURE
AL
TEMP. CONTROL
STEAM SUPPLY
-+-MPS-j-
MPS
MEDIUM PRESSURE
AP
ACCESS PANEL
STEAM SUPPLY
4/-HPST
HPS
HIGH PRESSURE
BHP
PR ESSURE
STEAM SUPPLY
RELIEF VALVE
LOW PRESSURE
---LPR
LPR
STEAM CONDENSATE
STRAINER
RETURN
-
BLOW-OFF
MEDIUM PRESSURE
- �-MPR -f-
MPR
STEAM CONDENSATE
CC
EN D CONNECTIO
RETURN
CFH
CUBIC FEET PER
MEDIUM PRESSURE
-4-/-HPR-*
HPR
STEAM CONDENSATE
CFM
ECTI
RETURN
-0
PR
PUMPED CONDENSATE
CH
CHILLER
RETURN
RS
RS
REFRIGERANT
DESIGNATION
SUCTION
RL
RL
REFRIGERANT
RETURN UNIT
LIQUID
- ---RHG
RHG
REFRIGERANT
dB
r •
HOT GAS
DR
DR
EQUIP. DRAIN
D
D
INDIRECT DRAIN
V
V
VENT
IW
1W
INDUSTRIAL WATER
—SCW —
SCW
SOFT COLD WATER
FITTINGS:
AIR DEVICE x•11
r oom,
DP
DISCHARGE PLENUM
PRESSURE
DWG
P & T
TEMPERATURE
EA
r
PORT TAPS
--�--
CR
CONCENTRIC
II III I
EXIST. THERMOSTAT,
REDUCER
EER
ER
ECCENTRIC
.•
REDUCER
EJ
—�--
EJ
EXPANSION
EFF
EFFICIENCY
JOINT
ENT
U
UNION
'
THERMOMETER
• , : - w
W /THERMOWELL
`F
AV
AIR VENT
-��--
FC
FLEXIBLE PIPE
F.G.
• -
CONNECTOR
Fs
FS
FLOW SWITCH
Ps
FULL LOAD AMP.
PRESSURE
FPI
PS
SWITCH
j
FEET PER MINUTE
PRESSURE
ERIC.
PG
GAUGE W /GAUGE
FT
I DIREC11ON OF a
COCK
0
RISE IN DIRECTION
ELBOW UP
c
OF AIRFLOW
ELBOW DOWN
�-
r -•► I i � r 'i
TEE UP
.�
OF •
TEE DOWN
w i i
PIPE CAP OR
PLUG
NOTES
1. NEW DUCTWORK IS HEAVY LINE WEIGHT AND /OR SHADED.
SYMBOL
ABBR
DESCRIPTION
SYMBOLS:
MCC
GAL
GALLON
CENTER
UNDERCUT DOOR
"
•
OUTSIDE STEM AND
GALLONS PER
PROTECTION
Y
D L
D/L
DRAIN
GRAVITY VENTILATOR,
PRE - FILTER
H OSE END CO
L D
®
r i
wk NO
HEATING C01L
L/D
HEIGHT. (UNDER
HORSEPOWER
QTY.
CHECK VALVE WITH
HUMIDIFIER SECTION
RETURN AIR
IN DICATION OF •
HERTZ
RF
r• •
INCH WATER
•-
PR ESSURE
11
RPM
RE D U CING
ABBREVIATIONS:
MINUTE
S OLENO I D VALVE
(R)
REMOVE OR
AUTO FLOW CONTROL
r
RELOCATE
(E)
(E)
EXISTING (PAREN-
.;.
LEAVING
THESIS AROUND
CI SETTER OR
T
ITEM INDICATES
BALA NCING
MAXIMUM
IT IS EXISTING)
GLOB
► �f
NEW
SOUND TRAP
DN
DOWN
. .
=A
ABOVE FIN. FLOOR
GLOBE VALVE
AFG
ABOVE FIN. GRADE
(ANGLE PATTERN)
TOD
TOP OF DUCT (AFF)
NOTED
BUTTERFLY
BOT. OF DUCT (AFF
VAV
TOP
V
VELOCITY
NTS
NOT TO SCALE
AF
AUT
VENT THROUGH
AFF
TEMP. CONT
WB
WET -BULB
FLOOR
,r
AH
AUTOMA
W/O
AL
TEMP. CONTROL
AMB.
VALVE, 3-WAY
AP
ACCESS PANEL
B
. .,
BHP
PR ESSURE
RELIEF VALVE
BTUH
RISER
STRAINER
-
BLOW-OFF
: CAPPED HO
CC
EN D CONNECTIO
CFH
CUBIC FEET PER
:•
-SECTION No
CFM
ECTI
HEET i
TT
CH
CHILLER
COP
D ET A IL
DESIGNATION
CRU
CONDENSATE
RETURN UNIT
CV
E
®
dB
r •
Q Em
DB
N
DDC
DIRECT DIGITAL
CONTROL
.
• •
DIA
DISCONNECTION
DN
AIR DEVICE x•11
r oom,
DP
DISCHARGE PLENUM
DWG
D EVICES.
EA
r
EDR
O
"
II III I
EXIST. THERMOSTAT,
EER
I
NEW THE
.•
EF
E •-
EFF
EFFICIENCY
ENT
r ` HUMI
'
• , : - w
`F
SENS
Q)
FC
CARBON DIOXID
F.G.
• -
FF
CARBON MONOXIDE
FLA
FULL LOAD AMP.
FPI
FINS PER INCH
FPM
FEET PER MINUTE
ERIC.
A RROW IN D ICATES
FT
I DIREC11ON OF a
FS
RISE IN DIRECTION
FT. W.C.
OF AIRFLOW
r -•► I i � r 'i
OF •
w i i
SYMBOL
ABBR
DESCRIPTION
SYMBOLS:
MCC
GAL
GALLON
CENTER
UNDERCUT DOOR
UC v
UC
(UNDER ARCH.
GALLONS PER
PROTECTION
SECTION
D L
D/L
DOOR LOUVER
(UNDER ARCH.
GRAVITY VENTILATOR,
PRE - FILTER
SECTION
L D
PSIG
LOUVER DOOR FUL
HEATING C01L
L/D
HEIGHT. (UNDER
HORSEPOWER
QTY.
ARCH. SECTION
HUMIDIFIER SECTION
RETURN AIR
RETURN/ EXHAUST
HERTZ
RF
AIR FLOW SYMBOL
INCH WATER
RELATIVE HUMIDITY
SUPPLY AIR
COLUMN
RPM
FLOW SYMBOL
ABBREVIATIONS:
MINUTE
(R)
(R)
REMOVE OR
LBS
POUNDS
RELOCATE
(E)
(E)
EXISTING (PAREN-
LVG.
LEAVING
THESIS AROUND
MA
MAKE -UP AIR
ITEM INDICATES
MAX.
MAXIMUM
IT IS EXISTING)
(N)
(N)
NEW
SOUND TRAP
DN
DOWN
TSP
AFF
ABOVE FIN. FLOOR
PRESSURE
AFG
ABOVE FIN. GRADE
UON
TOD
TOP OF DUCT (AFF)
NOTED
BOD
BOT. OF DUCT (AFF
VAV
TOP
TOP OF PIPE (AFF)
VELOCITY
NTS
NOT TO SCALE
AF
AFTER FILTER
VENT THROUGH
AFF
ABOVE FINISHED
WB
WET -BULB
FLOOR
WATER FILTRATION
AH
AIR HANDLING UNIT
W/O
AL
ALUMINUM
AMB.
AMBIENT
AP
ACCESS PANEL
B
BOILER
BHP
BRAKE HORSE
POWER
BTUH
BRITISH THERMAL
UNIT PER HOUR
CAV
CONSTANT AIR
VOLUME
CC
COOLING COIL
CFH
CUBIC FEET PER
HOUR
CFM
CUBIC FEET PER
MINUTE
CH
CHILLER
COP
COEFFICIENT OF
PERFORMANCE
CRU
CONDENSATE
RETURN UNIT
CV
CONSTANT VOLUME
dB
DECIBEL
DB
DRY -BULB
DDC
DIRECT DIGITAL
CONTROL
DEFL
DEFLECTION
DIA
DIAMETER
DN
DOWN
DP
DISCHARGE PLENUM
DWG
DRAWING
EA
EXHAUST AIR
EDR
EFFECTIVE DIRECT
RADIATION
EER
ENERGY EFFICIENT
RATIO
EF
EXHAUST FAN
EFF
EFFICIENCY
ENT
ENTERING
ESP
EXTERNAL STATIC
PRESSURE
`F
DEGREE FAHRENHEI
FC
FAN COIL UNIT
F.G.
FIBERGLASS
FF
FINAL FILTER
FLA
FULL LOAD AMP.
FPI
FINS PER INCH
FPM
FEET PER MINUTE
ERIC.
FRICTION
FT
FLASH TANK
FS
FLOOR SINK
FT. W.C.
FEET WATER
COLUMN
SYMBOL ABBR
DESCRIPTION
ABBREVIATIONS:
MIN. CIRCUIT AMPS.
MCC
GAL
GALLON
CENTER
GPH
GALLONS PER HOUR
MOCP
GPM
GALLONS PER
PROTECTION
P.D.
MINUTE
GV
GRAVITY VENTILATOR,
PRE - FILTER
PRESS
GATE VALVE
PSIG
HC
HEATING C01L
INCH GAUGE
HP
HORSEPOWER
QTY.
HU
HUMIDIFIER SECTION
RETURN AIR
HZ
HERTZ
RF
IN. W.C.
INCH WATER
RELATIVE HUMIDITY
RLA
COLUMN
RPM
ISOL.
ISOLATOR
MINUTE
KW
KILOWATTS
SA
LBS
POUNDS
STANDARD AIR CUBIC
LBS /HR
POUNDS PER HOUR
SF
LVG.
LEAVING
SHEET
MA
MAKE -UP AIR
S.P.
MAX.
MAXIMUM
SQUARE
MCA
MINIM CIRCUIT
ST
SOUND TRAP
AMP
MBH
THOUSAND BTUH
MCA
MIN. CIRCUIT AMPS.
MCC
MOTOR CONTROL
OA
CENTER
MIN.
MINIMUM
MOCP
MAX. OVER CURREN'
P
PROTECTION
MTL
METAL
MUA
MAKE -UP AIR UNIT
NC
NOISE CRITERIA
OA
OUTSIDE AIR
O.C.
ON CENTER
OPNG
OPENING
P
PUMP
P.D.
PRESSURE DROP /
DIFFERENTIAL
PF
PRE - FILTER
PRESS
PRESSURE
PSIG
POUNDS PER SQUARI
INCH GAUGE
PWL
SOUND POWER LEVEL
QTY.
QUANTITY
RA
RETURN AIR
REF
REFERENCE
RF
RETURN FAN
RH
RELATIVE HUMIDITY
RLA
RUNNING LOAD AMP
RPM
REVOLUTION PER
MINUTE
RQD
REQUIRED
SA
SUPPLY AIR
SCFM
STANDARD AIR CUBIC
FEET PER MINUTE
SF
SUPPLY FAN
SHT
SHEET
SPECS
SPECIFICATIONS
S.P.
STATIC PRESSURE
SQ.
SQUARE
SS
STAINLESS STEEL
ST
SOUND TRAP
TG
TRANSFER GRILLE
TSP
TOTAL STAIC
PRESSURE
TYP
TYPICAL
UON
UNLESS OTHERWISE
NOTED
UTR
UP THROUGH ROOF
VAV
VARIABLE AIR VOLUME
VEL.
VELOCITY
VSD
VARIABLE SPEED
DRIVE
VTR
VENT THROUGH
ROOF
WB
WET -BULB
WF
WATER FILTRATION
W/
WITH
W/O
WITHOUT
FOR BUILDER PERMIT
AND PRICING ONLY
NOT FOR CONSTRUCTION
i
T
i
ui
i
•
•
r !•
•o 0
0
uj
+o
a �
0
k
N c
•
DRAWN BY: KAP
CHECKED BY: MPD
DATE: 05/16/08
SCALE: AS NOTED
OB NUMBER:
VV 08007.00
SHEET INF ORMATIO N:
MECHANICAL
LEGEND
SHEET NUMBER:
ISSUE / REVISIONS:
4 -15 -08 DD / PRELIMINARY PRICING SET
5 -5 -08 95% CD REVIEW SET
5 -16 -08 PERMIT SET
GENERAL MECHANICAL CONTRACT REQUIREMENTS:
1. UNLESS OTHERWISE NOTED, THE WORK DESCRIBED ON THE PLANS AND SPECIFICATIONS
SHALL INCLUDE THE FURNISHING AND INSTALLATION OF ALL LABOR AND MATERIALS
NECESSARY FOR COMPLETE AND OPERATIONAL HVAC, FIRE PROTECTION & PLUMBING
SYSTEMS. CONTRACTOR SHALL FURNISH THESE EVEN IF ITEMS REQUIRED TO ACHIEVE
THIS (I.E. OFFSETS, ISOLATION AND BALANCING DEVICES, MAINTENANCE CLEARANCES,
ETC.) ARE NOT SPECIFICALLY SHOWN.
2. DATA GIVEN ON THE DRAWINGS IS AS EXACTAS COULD BE SECURED. ABSOLUTE
ACCURACY IS NOT GUARANTEED AND THE CONTRACTOR SHALL OBTAIN AND VERIFY
EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE REQUIREMENTS, POTENTIAL
CONFLICTS WITH OTHER TRADES, ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT
HIS WORK TO THE ACTUAL CONDITIONS OF THE JOB.
3. THE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND SHALL NOT BE SCALED. THEY
SHOW CERTAIN PHYSICAL RELATIONSHIPS WHICH MUST BE ESTABLISHED WITHIN THE
DIVISION 15 WORK AND ITS INTERFACE WITH OTHER WORK, ESTABLISHING THIS
RELATIONSHIP IN THE FIELD IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR.
THIS DIVISION SHALL COORDINATE ITS WORK WITH ALL DIVISIONS OF THE WORK AND
ADJUST ITS WORK AS REQUIRED BY THE ACTUAL CONDITIONS OF THE PROJECT.
A. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING A BID TO BECOME
THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THE PROJECT.
B. CERTAIN SYSTEMS REQUIRE ENGINEERING OF INSTALLATION DETAILS BY
CONTRACTOR. UNLESS FULLY DETAILED IN THE CONTRACT DOCUMENTS, SUCH
ENGINEERING IS THE EXCLUSIVE RESPONSIBILITY OF THE CONTRACTOR.
C. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHERE CLEARANCES ARE
LIMITED, AND WHERE INSTALLATION DRAWINGS OR SCHEMATICS, "CONSTRUCTION
DRAWINGS ", OR COORDINATION DRAWINGS MAY BE REQUIRED. THE CONTRACTOR
SHALL PREPARE ALL SUCH COORDINATION DRAWINGS AS PART OF THE BASE
CONTRACT. SUCH DRAWINGS MAY BE SUBMITTED TO THE ARCHITECT /ENGINEER FOR
RECORD AND COMMENT (AT THE CONTRACTOR'S OPTION).
NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING
CONDITIONS.
4. COORDINATE AND ADJUST ALL WORK BETWEEN TRADES AND EXISTING CONDITIONS IN
ORDER TO ACCOMPLISH A NEAT, INTEGRATED AND EFFICIENT INSTALLATION.
EXAMINE THE CONTRACT DOCUMENTS OF ALL TRADES (E.G., THE ARCHITECTURAL
REFLECTED CEILING PLAN, ELECTRICAL LIGHTING PLAN, FIRE PROTECTION PLAN, ETC.).
COORDINATE NECESSARY EQUIPMENT, DUCTWORK AND PIPING LOCATIONS SO THAT THE
FINAL INSTALLATION IS COMPATIBLE WITH THE MATERIALS AND EQUIPMENT OF THE OTHER
TRADES.
AS NECESSARY, PREPARE SHOP DRAWINGS FOR INSTALLATION OF ALL NEW WORK
BEFORE INSTALLATION TO VERIFY COORDINATION OF WORK BETWEEN TRADES.
5. REFER TO THE ARCHITECTURAL DIVISION FOR EXACT LOCATION OF ALL VISIBLE FIXTURES,
EQUIPMENT AND AIR DEVICES.
A. FINAL LOCATION OF ALL THERMOSTATS IN FINISHED SPACES AND ALL ROOM AIR
SENSORS SHALL BE AS INDICATED ON THE ARCHITECTURAL DRAWINGS. IF NOT
SHOWN ON THE ARCHITECTURAL DRAWINGS, FIELD COORDINATE WITH ARCHITECT
PRIOR TO INSTALLATION.
6. MAINTAIN A MARK -UP SET OF DRAWINGS WHICH INDICATE VARIATIONS IN THE ACTUAL
INSTALLATION FROM THE ORIGINAL DESIGN. SURRENDER DRAWINGS TO OWNER UPON
COMPLETION.
7. ALL CAPACITIES ARE SCHEDULED AT JOBSITE ALTITUDE OF 8150 FT. ABOVE SEA LEVEL.
8. VERIFY THE ELECTRICAL SERVICE PROVIDED BY THE ELECTRICAL CONTRACTOR BEFORE
ORDERING ANY MECHANICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS.
9. PROVIDE HIGH EFFICIENCY MOTORS WITH 1.15 SERVICE FACTOR ON ALL EQUIPMENT,
MOTORS SHALL BE CAPABLE OF OPERATING CONTINUOUSLY AT 105OF UNDER JOBSITE
CONDITIONS AND ALTITUDE.
10. UNLESS NOTED OTHERWISE, ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH HOA
SWITCH AND STARTER COMPATIBLE WITH EQUIPMENT AND BMS SYSTEM. STARTERS
SHALL BE PROVIDED BY DIVISION 15 UNLESS IN A MOTOR CONTROL CENTER. ALL
DISCONNECTS SHALL BE FURNISHED BY DIVISION 16. SEE ALSO DIVISION 01042 OF THE
SPECIFICATIONS.
11. THE ELECTRICAL POWER FOR CERTAIN EQUIPMENT PROVIDED UNDER DIVISION 15, HAS
NOT BEEN SPECIFICALLY INDICATED ON THE ELECTRICAL DRAWINGS AND MUST BE
PROVIDED BY AND FIELD COORDINATED BY THE DIVISION 15 TRADE REQUIRING SUCH
POWER.
SUFFICIENT POWER FOR THIS PURPOSE SHALL BE FURNISHED AS "SPARE ", DEDICATED
CIRCUIT CAPACITY IN DIVISION 16'S PANELBOARDS. ALL WIRING, CONDUIT AND
ELECTRICAL DEVICES DOWNSTREAM OF THE PANELBOARDS IS THE RESPONSIBILITY OF
THE DIVISION 15 TRADE REQUIRING THE POWER UNLESS OTHERWISE SHOWN ON THE
ELECTRICAL DRAWINGS.
SUCH EQUIPMENT 1S HEREBY DEFINED AS:
A. TEMPERATURE CONTROL PANELS, CONTROL AIR COMPRESSORS AND LINE VOLTAGE
POWER FOR 24V CONTROL TRANSFORMERS. REQUIRED CONNECTION ARE INCLUDED
IN DIVISION 15950 AND WILL BE SHOWN BY THAT CONTRACTOR'S CONTROL SUBMITTAL
DRAWINGS.
B. IT IS NOT PERMISSIBLE TO UTILIZE "SPARE" POWER FROM ADJACENT POWER CIRCUITS
TO SERVE ANY OF THE ABOVE LOADS. ALL POWER MUST COME FROM DEDICATED
CIRCUITS.
12, SUSPEND EACH TRADE'S WORK SEPARATELY FROM THE STRUCTURE. DUCTWORK SHALL
BE HELD TIGHT TO STRUCTURE EXCEPT WHERE OTHERWISE SHOWN.
13. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL
CODES OR REGULATIONS TAKE PRECEDENCE.
14. PROVIDE MANUFACTURER'S RECOMMENDED SERVICE CLEARANCE ALL AROUND ALL
EQUIPMENT REQUIRING SAME.
15. PROVIDE FOR SAFE CONDUCT OF THE WORK, CAREFUL REMOVAL AND DISPOSITION OF
MATERIALS AND PROTECTION OF PROPERTY WHICH IS TO REMAIN UNDISTURBED.
17. ALL CURBS, ROOF JACKS, ROOF THIMBLES, SANITARY VENTS, ROOF DRAINS, ETC. SHALL
BE COMPATIBLE WITH THE EPDM ROOFING SYSTEM TO BE PROVIDED. REFERENCE
ARCHITECTURAL REVISION FOR REQUIRED FLASHING DETAILS.
18. WARRANTY: THE ENTIRE MECHANICAL SYSTEM SHALL BE WARRANTED AGAINST DEFECTS
IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER ACCEPTANCE
OF THE SYSTEM BY THE OWNER.
19. DEFINITIONS:
A. THE DEFINITIONS OF DIVISION 1 AND THE GENERAL CONDITIONS OF THIS
SPECIFICATION ALSO APPLY TO THE DIVISION 15 CONTRACT.
B "CONTRACT DOCUMENTS" CONSTITUTE THE DRAWINGS, SPECIFICATIONS, GENERAL
CONDITIONS, PROJECT MANUALS, ETC., PREPARED BY ENGINEER (OR OTHER DESIGN
PROFESSIONAL IN ASSOCIATION WITH ENGINEER) FOR CONTRACTOR'S BID OR
CONTRACTOR'S NEGOTIATIONS WITH THE OWNER. THE DIVISION 15 DRAWINGS AND
SPECIFICATIONS PREPARED BY THE ENGINEER ARE NOT CONSTRUCTION DOCUMENTS.
C. "CONSTRUCTION DOCUMENTS ", "CONSTRUCTION DRAWINGS", AND SIMILAR TERMS
FOR DIVISION 15 WORK REFER TO INSTALLATION DIAGRAMS, SHOP DRAWINGS AND
COORDINATION DRAWINGS PREPARED BY THE CONTRACTOR USING THE DESIGN
INTENT INDICATED ON THE ENGINEER'S CONTRACT DOCUMENTS. THESE
SPECIFICATIONS DETAIL THE CONTRACTOR'S RESPONSIBILITY FOR "ENGINEERING BY
CONTRACTOR" AND FOR PREPARATION OF CONSTRUCTION DOCUMENTS.
D. "(N }" INDICATES "NEW" EQUIPMENT TO BE PROVIDED UNDER THIS CONTRACT.
E. "(E)" INDICATES "EXISTING" EQUIPMENT ON SITE WHICH MAY OR MAY NOT NEED TO BE
RELOCATED AS A PART OF THIS WORK.
F. "(R)" INDICATES EXISTING EQUIPMENT TO BE RELOCATED AS PART OF THIS WORK.
G. "FURNISH" MEANS TO "SUPPLY" AND USUALLY REFERS TO AN ITEM OF EQUIPMENT.
H. "INSTALL" MEANS TO "SET IN PLACE, CONNECT AND PLACE IN FULL OPERATIONAL
ORDER ".
1. "PROVIDE" MEANS TO "FURNISH AND INSTALL ".
J. "EQUIVALENT" MEANS "MEETS THE SPECIFICATIONS OF THE REFERENCE PRODUCT OR
ITEM IN ALL SIGNIFICANT ASPECTS." SIGNIFICANT ASPECTS SHALL BE AS DETERMINED
BY THE ARCHITECT /ENGINEER.
K. "WORK BY OTHER(S) DIVISIONS "; "RE: DIVISION ", AND SIMILAR EXPRESSIONS MEANS
WORK TO BE PERFORMED UNDER THE CONTRACT DOCUMENTS, BUT NOT
NECESSARILY UNDER THE DIVISION OR SECTION OF THE WORK ON WHICH THE NOTE
APPEARS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO COORDINATE THE
WORK OF THE CONTRACT BETWEEN HIS /HER SUPPLIERS, SUBCONTRACTORS AND
EMPLOYEES. IF CLARIFICATION IS REQUIRED, CONSULT ARCH ITECTIENGINEER
BEFORE SUBMITTING BID.
L. BY INFERENCE, ANY REFERENCE TO A "CONTRACTOR" OR "SUB - CONTRACTOR" MEANS
THE ENTITY WHICH HAS CONTRACTED WITH THE OWNER FOR THE WORK OF THE
CONTRACT DOCUMENTS.
M. "ENGINEER" MEANS THE DESIGN PROFESSIONAL FIRM WHICH HAS PREPARED THESE
CONTRACT DOCUMENTS. ALL QUESTIONS, SUBMITTALS, ETC. OF THIS DIVISION SHALL
BE ROUTED TO THE ENGINEER (THROUGH PROPER CONTRACTURAL CHANNELS).
20. CONTRACTOR REQUIREMENTS: SUBMIT A STATEMENT OF QUALIFICATION LISTING SIMILAR
PROJECTS COMPLETED IN THE LAST FIVE (5) YEARS. CONTRACTOR SHALL HAVE A
MINIMUM OF FIVE (5) YEARS EXPERIENCE IN THIS TYPE OF WORK, AND SUBMIT EVIDENCE
OF THAT FACT WITH HIS BID. INADEQUATE EXPERIENCE AS DETERMINED BY THE ENGINEER
SHALL BE CAUSE FOR REJECTION OF CONTRACTOR'S BID.
21. PROVIDE ALL REQUIRED PERMITS, INSPECTIONS AND COORDINATION WITH GOVERNING
AUTHORITIES. INSTALLATION TO CONFORM WITH APPLICABLE PROVISIONS OF:
A. APPLICABLE LOCAL, STATE AND FEDERAL CODES, LAWS AND REGULATIONS.
B. REQUIREMENTS OF FIRE DEPARTMENT, WASTEWATER DEPARTMENT, HEALTH
DEPARTMENT AND STATE OIL INSPECTOR SERVICING THE PROJECT.
C. INTERNATIONAL BUILDING, MECHANICAL AND PLUMBING CODES. INCLUDING THE
TOWN OF VAIL AMENDMENTS TO THE INTERNATIONAL BUILDING CODE.
D. APPLICABLE PAMPHLETS OF THE NFPA INCLUDING THE NATIONAL ELECTRICAL CODE.
E. AMERICANS WITH DISABILITIES ACT (ADA).
22. KEEP DEMOLITION & CUTTING TO MINIMUM REQUIRED FOR PROPER EXECUTION OF WORK.
BE RESPONSIBLE FOR ALL CUTTING AND PATCHING NECESSARY FOR THE COMPLETION OF
THE WORK.
NO CUTTING (NOT SHOWN ON THE CONTRACT DOCUMENTS) SHALL BE DONE WITHOUT THE
APPROVAL OF THE ARCHITECT, OWNER & ENGINEER AS TO LOCATIONS, METHOD AND
EXTENT OF THE CUTTING.
23. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING CONSTRUCTION
WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY, APPEARANCE OR FUNCTION.
24. IF UNABLE TO OBTAIN WITHIN 85 % OF THE REQUIRED CFM QUANTITIES IN ANY TERMINAL
UNIT, AIR DIFFUSION DEVICE, BRANCH OR MAIN DUCT, NOTIFY ENGINEER IMMEDIATELY,
THEN PERFORM A VISUAL INSPECTION AND /OR PITOT TUBE TRAVERSE TO IDENTIFY THE
SOURCE OF THE OBSTRUCTION. REMOVE THE OBSTRUCTION AND RE- BALANCE.
25. SUBMIT EQUIPMENT CUT SHEETS AND CONTROL DIAGRAMS FOR REVIEW AND RECORD.
SUBMITTALS MUST BE REVIEWED AND NOT REJECTED BEFORE WORK BEGINS.
MANUFACTURER LISTED IS BASIS OF DESIGN. SUBSTITUTIONS MAY BE OFFERED DURING
THE SUBMITTAL PHASE. JUDGMENT OF EQUIVALENCY SHALL BE MADE BY THE ENGINEER.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING CLEARANCE, DIMENSIONS,
ELECTRICAL AND OTHER UTILITY REQUIREMENTS AND CONNECTIONS TO OTHER WORK.
26. QUALITY CONTROL:
A. QUALIFICATION OF PRODUCTS: WHEN PRODUCTS ARE SPECIFIED BY MANUFACTURER
AND MODEL NUMBER, EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS LISTED
MAY BE PROVIDED. PRODUCT EQUIVALENCY SHALL BE DETERMINED BY ENGINEER.
B. IF A PRODUCT SUBMITTED AS AN EQUIVALENT IS DEEMED UNACCEPTABLE TO THE
ENGINEER, THE SPECIFIED PRODUCT SHALL BE PROVIDED AT NO EXTRA COST TO THE
PROJECT.
D. SUBMIT CUT SHEETS ON ALL OF THE SPECIFIED EQUIPMENT.
E. SUBMIT A WRITTEN BALANCE REPORT BY A NTF (NATIONAL TRAINING FUND OF
SMACNA); CERTIFIED BALANCING CONTRACTOR. MEASUREMENTS SHALL INCLUDE
SUPPLY AND EXHAUST FAN MOTOR AMPERAGE AND VOLTAGE READINGS; MOTOR AND
FAN RPMS; STATIC PRESSURE AT INLET AND OUTLET OF ALL FANS, COILS, AND
FILTERS; PITOT TUBE TRAVERSE OF SUPPLY, EXHAUST, RETURN, AND OUTSIDE AIR
MAIN DUCTS, AT 0 % OUTSIDE AIR, MINIMUM OUTSIDE AIR, AND 100% (ECONOMIZER)
OUTSIDE AIR; AIR INLET AND OUTLET QUANTITIES; WATER FLOW, TEMPERATURE DROP,
AND PRESSURE DROP AT ALL COILS. THEY SHALL ALSO INCLUDE STATIC AND
VELOCITY PRESSURE READINGS AT THE SUPPLY PLENUM, EXHAUST RISERS AND ALL
BRANCH DUCTWORK; VELOCITY DISTRIBUTION ACROSS THE FACE OF THE SUPPLY
AND EXHAUST FILTERS.
(1) PROVIDE ALL REQUIRED SHEAVES, BELTS, TESTING EQUIPMENT, ETC. NECESSARY
TO BALANCE THE HVAC SYSTEM IN ACCORDANCE WITH THE CONTRACT
DOCUMENTS.
F. SUBMIT FOUR (4) COPIES OF ALL SUBMITTALS IN ADDITION TO ANY REQUIRED BY THE
CONTRACTOR AND HIS SUPPLIERS. THESE COPIES SHALL BE RETAINED BY THE
OWNER, ARCHITECT AND ENGINEER.
27. SUBMIT TWO (2) COPIES OF ALL OPERATING MANUALS AND WARRANTIES IN BOUND
NOTEBOOKS TO OWNER.
28. FINAL PAYMENT SHALL BE ISSUED ONLY AFTER OWNER HAS ACCEPTED ALL WORK AND
MANUALS, RECORD DRAWINGS, ETC. HAVE BEEN SUBMITTED SATISFACTORILY.
29. ACCESS PANELS:
A. ACCESS PANELS: EQUIVALENT TO CESCO "HAD ", HINGED, (2) CAM LOCKS, GASKETED.
30. PIPING:
A. PIPE INSTALLATION:
(1) ALL PIPING SHALL BE ADEQUATELY SUPPORTED FROM THE BUILDING STRUCTURE
TO PREVENT SAGGING, POCKETING, SWAYING OR DISPLACEMENT BY MEANS OF
HANGERS AND SUPPORTS. PIPING IS NOT TO BE SUPPORTED BY EQUIPMENT.
(2) PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR MATERIALS.
(3) PROVIDE MANUAL AIR VENTS AND CAPPED HOSE -END DRAINS WITH ISOLATION
VALVES AT PIPING HIGH AND LOW POINTS.
(4) WELD PIPE IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS.
WELDERS SHALL BE CERTIFIED FOR TYPE OF WORK BEING PERFORMED.
(5) FLUSH OUT PIPING AND REMOVE CONTROL DEVICES BEFORE PERFORMING
PRESSURE TEST. DO NOT USE PIPING SYSTEM VALVES TO ISOLATE SECTIONS
WHERE TEST PRESSURE EXCEEDS VALVE PRESSURE RATING. PRESSURIZE
PIPING AT 100 PSIG. IF LEAKAGE IS OBSERVED OR IF TEMPERATURE
COMPENSATED PRESSURE DROP EXCEEDS 1 %o OF TEST PRESSURE, REPAIR
LEAKS AND RETEST.
(6) PLASTIC PIPE: AIR PRESSURE TEST ALL PLASTIC PIPE AND PEX PIPE SYSTEMS
ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
a. DO NOT USE AIR PRESSURE TO TEST PVC OR CPVC PIPE.
(7) ALL STRAINERS SHALL BE FURNISHED WITH A "ROUGHING" SCREEN AND TWO (2)
SCREENS FOR NORMAL OPERATION. INSTALL STRAINER WITH ROUGHING SCREEN
AND OPERATE SYSTEM FOR 24 HOURS MINIMUM (RUN DOMESTIC WATER SYSTEMS
AT MAX FLOW FOR A MINIMUM OF ONE HALF (1/2) HOUR. REMOVE ROUGHING
SCREEN AND INSTALL NORMAL SCREEN, AFTER TWO WEEKS OF NORMAL
OPERATION INSTALL NEW NORMAL SCREEN.
B. PIPE AND FITTINGS:
(1) HWS, HWR, RFS, RFR, SMS, SMR:
a. SIZE 2" AND SMALLER: ANY OF THE FOLLOWING:
(i) STEEL PIPE, SCHEDULE 40 WITH 125 PSI CAST IRON THREADED FITTINGS.
(ii) COPPER TUBE, HARD TEMPER, TYPE L WITH WROUGHT COPPER FITTINGS,
WITH 95 -5 TIN - ANTIMONY SOLDER FOR COPPER TUBE JOINTS.
(iii) AQUAPEX & MULTICOLOR PEX PIPING FOR DISTRIBUTION TO HOT WATER
BASEBOARD, MANIFOLDS, ETC. IS AN APPROVED EQUAL FOR COPPER
PIPING.
b. SIZE 2 -1/2" AND LARGER: STEEL PIPE, SCHEDULE 40 WITH ANY OF THE
FOLLOWING FITTINGS:
(i) BLACK STEEL STANDARD WROUGHT BUTT WELD.
(ii) 125 LB CAST IRON FLANGED.
(iii) MALLEABLE OR DUCTILE IRON GROOVED PIPE FITTINGS, DESIGNED FOR
CUT GROOVED JOINT.
31. MECHANICAL INSULATION:
F.11 0 I, riv F*-Zj s_
B. (P /SL) REFER TO BULLETIN 173 (DATED JULY 23, 1991) FOR REQUIRED TYPE AND
THICKNESSES.
(1) SEAL ALL PIPING WHICH IS NORMALLY COLDER THAN AMBIENT WITH VAPOR
BARRIER RATED MASTIC.
(2) TYPE A: FIBERGLASS PIPE INSULATION WITH SELF ADHESIVE ALL SERVICE VAPOR
BARRIER JACKET. FITTINGS INSULATED WITH FIBERGLASS INSERTS IN PVC
FITTING COVERS. ALL MATERIALS FLAME SPREAD 25, SMOKE DEVELOPED 50.
(3) TYPE B: FLEXIBLE ELASTOMERIC CLOSED CELL PIPE INSULATION, FLAME SPREAD
25, SMOKE DEVELOPED 50.
(4) TYPE C: FLEXIBLE FIBERGLASS BLANKET WITH REINFORCED KRAFT /ALUMINUM
FOIL VAPOR BARRIER FACING.
(5) TYPE D: SEMI -RIGID FIBERGLASS BOARD WITH REINFORCED VAPOR BARRIER
FACING, 3 LBS /CU.FT. DENSITY.
(6) TYPE E: FIBERGLASS BONDED TO FLEXIBLE ALL SURFACE JACKET. FIBERGLASS
SLIT OR ORIENTED TO ALLOW CONFORMANCE TO ROUND SURFACES. DENSITY 3
LBS /CU.FT.
C. APPLICATION:
(1) ABOVE GROUND HEATING HOT WATER.
a. RUNOUTS TO TERMINALS -1/2" THICK TYPE A.
b. ALL OTHER 1" THICK TYPE A.
(2) REPAIRS TO EXISTING SYSTEMS:
a. MATCH MATERIAL AND THICKNESS AS CLOSE AS POSSIBLE.
THE OPERATION OF THE BOILER, CIRCULATING PUMP AND THE DOMESTIC HOT WATER
GENERATOR PUMP SHALL BE CONTROLLED VIA A TEKMAR CONTROLLER. UPON A CALL FOR
HEATING, THE BOILER SHALL FIRE TO MAINTAIN A DISCHARGE WATER TEMPERATURE OF
140° F (ADJ). UPON A CALL FOR DOMESTIC HOT WATER PRODUCTION THE BOILER SHALL
RAMP UP TO PROVIDE A DISCHARGE TEMPERATURE OF 180° F (ADJ).
SNOWMELT ZONE: SZ -1
THE SNOWMELT SYSTEM PUMP SHALL BE CONTROLLED BY A TEKMAR 665 CONTROL PANEL
WITH ASSOCIATED 093 COMBINATION SOCKET / SENSOR. WHEN MOISTURE IS DETECTED
ON THE SENSOR AND TEMPERATURES ARE BELOW FREEZING, THE SYSTEM SHALL BE
ENERGIZED VIA THE TEKMAR 665 CONTROLLER. THE ASSOCIATED SNOWMELT PUMP SHALL
BE ENABLED AND THE HEAT EXCHANGER SHALL BE ENABLED TO MAINTAIN THE SNOWMELT
LOOP SUPPLY TEMPERATURE OF 130° F (ADJ).
RADIANT ZONES: RZ -1 THRU RZ -12
UPON A CALL FOR HEATING FROM A WALL MOUNTED THERMOSTAT, ASSOCIATED ZONE
VALVES SHALL OPEN, THE RADIANT PUMP SHALL BE ENABLED, AND THE MOTORIZED 3 -WAY
VALVE SHALL MODULATE TO MAINTAIN THE PRIMARY RADIANT LOOP TEMPERATURE OF
130° F (ADJ).
SUPPLEMENTAL HEATING: UPON A CALL FOR SUPPLEMENTAL HEATING (2ND STAGE
HEATING) FROM A WALL MOUNTED THERMOSTAT, THE HOT WATER BASEBOARD SHALL BE
ENABLED UNTILL THE CALL IS SATISFIED.
EXHAUST FANS EF -1
BATHROOM EXHAUST FAN SHALL BE CONTROLLED BY AN INDEPENDENT WALL SWITCH.
Lg�
I ps
i
•
•
M
i
•
i
r
�
tiyuQ ci
tA
16. PROVIDE ACCESS DOORS FOR ALL EQUIPMENT, VALVES, CLEANOUTS, ACTUATORS AND
CONTROLS WHICH REQUIRE ACCESS FOR ADJUSTMENT OR SERVICING AND WHICH ARE
LOCATED IN OTHERWISE UNACCESSIBLE LOCATIONS.
C. SUBMITTALS SHALL INCLUDE REVISED AND SUPPLEMENTED CONTROL DIAGRAMS.
r
DRAWN BY: KAP
CHECKED BY: MPD _.._.
DATE: 05/16/08
SCALE: AS NOTED
w �
SHEET NUMBER:
MR
`°t� ! 1. MM+ k .
•
J' `
ISSUE / REVISIONS:
4 -15-08 DD / PRELIMINARY PRICING SET
5 -5-08 95% CD REVIEW SET
FAN SCHEDULE
5 -1608 PERMIT SET
ESP ELECTRICAL
OPER
MANUFACTURER/
"W.C. MAX HP
WEIGHT MAX NOTES
CODE MODEL NO. SERVICE LOCATION
TYPE CFM (ALT.) DRIVE RPM (WATTS) VOLT PH
LBS. SONES A B C D E F G H 1
EF -1 PANASONIC FV -08VQ3 RESTROOMS CEILING CEILING 57 0.25 DIRECT 909 22.6(W) 120 1 13.4 0.3 0 2 1 1 2 3 0 1 4
GENERAL NOTES
1.
CAPACITIES AT 8150 FT ELEVATION.
2.
MAXIMUM SONES SHOWN ARE AMCA CERTIFIED LEVELS BEFORE TAKING CREDIT
FOR SOUND ATTENUATION OF ROOF CURB. ATTENUATOR TO REDUCE SONES 50 %.
3.
FOR SOUND ATTENUATING CURBS, SIZE FAN 7% MORE CFM THAN SCHEDULED
TO ACCOUNT FOR CURB LOSS.
4.
LABEL FANS AS TO AREAS SERVED.
NOTES:
w
A.
CURB
0. NONE
E. ACCESSORIES H. MISCELLANEOUS
1. SOLID STATE SPEED CONTROL, MTD. IN MOTOR 0. NONE�.r/
f
1. FIELD- BUILT, INSULATED
COMPARTMENT FOR BALANCING. 1.
VIBRATION ISOLATORS.
,-
2. FACTORY - BUILT, INSULATED
2. ELECTRIC DISCONNECT. 2.
SECURE FAN TO CURB AT EACH
W
3. FACTORY- BUILT, INSULATED, 18" TALL
3. WALL MOUNTED SOLID STATE SPEED CONTROL
CORNER, EACH SIDE AND 12" O.C.
W
4. FACTORY -BUILT SOUND ATTENUATING
4. 115V/1 REVERSE ACTING THERMOSTAT, SET AT 85 F 3.
AMCA B SPARKPROOF, 3/4: SCROLL DRAIN
W
5. FACTORY VENTILATED GREASE
5. WALL MOUNTED 2 SPEED SWITCH
AND ACCESS PANEL
HOOD EXHAUST
6. DRAIN CONNECTION 4.
EXPLOSION PROOF
CL
6. FACTORY INSULATED EXTENDED HEIGHT CURB
7. CLEANABLE GREASE RECEPTOR 5.
2 SPEED /2 WINDING (1200/1800)
....�
7. REUSE (E) CURB. PROVIDE INSULATED
6.
2 SPEED /2 WINDING (900/1800)
LO
ADAPTORS AS REQUIRED
F. TYPE 7.
VARIABLE FREQUENCY DRIVE
(�
1. CEILING FAN 8.
EMERGENCY POWER
B.
SCREEN
2. CENTRIFUGAL ROOF EXHAUSTER
w 0
00
0. NONE
3. CABINET FAN I. CONTROL
Z
O
1. BIRD
4. WALL PROPELLER FAN 1.
INTERLOCK WITH HVAC UNIT WHICH SERVES SAME SYSTEM
2. INSECT
5. CENTRIFUGAL UPBLAST ROOF EXHAUSTER
(VIA DDC SYSTEM)
6. TUBEAXIAL UPBLAST ROOF EXHAUSTER 2.
RUN CONTINOUSLY, CONTROL VIA DDC SYSTEM
C.
DRIVE
7. CENTRIFUGAL UTILITY SET 3.
CONTROL VIA WALL SENSOR. ENERGIZE AT 85 F (ADJ)
1. DIRECT
8. CENTRIFUGAL SQUARE IN -LINE 4.
ENERGIZE VIA MANUAL WALL SWITCH
(�
J
2. BELT
5.
ENERGIZE VIA TIMECLOCK
"SEQUENCE
w
O
G. SPECIAL COATINGS 6.
SEE DIV 15950, OF OPERATION" SECTION
0
D.
DAMPER
0. NONE
0. NONE
1. PHENOLIC
W
1. GRAVITY BDD
2. EPDXY
2. BAROMETRIC ADJUSTABLE BDD
3. POLYESTER /EPDXY
3. MOTORIZED CONTROL DAMPER, 115V/1
4. EISENHEISS
'�"
4. MAGNETIC BUTTERFLY DAMPER LATCHES.
0 �
r�
HOT WATER GENERATOR SCHEDULE
vi
STORAGE BOILER MINIMUM
GPH @ OPER.
MANUFACTURER/
CAPACITY INPUT BOILER BOILER WATER TEMP. DOM. WATER
TEMP. 100' F RISE WT.
CODE MODEL NO. SERVICE
(GAL) (MBH) GPM EWT ("F) LWT ("F) EWT ('F)
LWT ("F) (S.L.) (LBS) REMARKS
WH -1 TURBOMAX -65 DOMESTIC HOT WATER
72 200 20 180 160 40
110 416 250
GENERAL NOTES
1. HEAT EXCHANGER AND TANK TO BE ASSEMBLED AT THE FACTORY AND
SHIPPED FULLY ASSEMBLED.
2. HEATING WATER CONTAINS 30% PROPYLENE GLYCOL
REMARK NOTES
A. MUST BE NSF APPROVED.
c►
B. HEAT EXCHANGER TO BE DOUBLE WALL.
N o
BOILER SCHEDULE
MANUFACTURER/
INPUT OUTPUT ELECTRICAL
FLUE GAS WEIGHT NOTES
,,' ° o
CODE MODEL NO. SERVICE MBH S.L. MBH ALT. GPM VOLT PH HZ
D IN. PRESSURE (PSIG) (LBS. A B C D
B -1 LOCHINVAR KBN500 SYSTEM
HEATING 500,000 324,000 32.4 120 1 60
2 4" 30 305 1 2 0 1
;
s
ZE
GENERAL NOTES
, -
1. EWT = 160" F, LWT = 180" F.
ZE
2. JOBSITE ELEVATION= 8150 FT.
3. FUEL TYPE = NATURAL GAS.
4. OPERATING WEIGHT INDICATED IN LBS.
yw
5. RELIEF VALVE SETPOINT IS 30 PSIG.
6. OVERSIZE BURNER (AND INCREASE SECTIONS) TO
OBTAIN SPECIFIED OUTPUT AT ALTITUDE.'
EQUIVALENT CFH AT ALTITUDE IS APPROX 804.
7. PROVIDE CONTROL TRANSFORMER AND STARTER.
8. PROVIDE REQUIRED STATE PERMITS AND INSPECTIONS.
NOTES:
A. FLUID
B. BURNER C. ACCESSORIES
D. MISCELLANEOUS
v vi
0. WATER
1. HI/LO FIRE 0, NONE
0, NONE
Cf %
1. 30% PROPYLENE GLYCOL
2. MODULATING 1. 30 PPPM LO NOX
1. HOT WATER
c
2. 35% PROPYLENE GLYCOL
2. DDC INTERFACE MODULE
2. STEAM
7¢
3. 50% PROPYLENE GLYCOL
3. BAROMETRIC DAMPER
3. ONE SIDE TUBE PULL
-n
4. PROBE LWCO
4. END TUBE PULL
•`
5. FULL LWCO
5. BACK OUTLET FLUE
"
6. SEPARATED COMBUSTION
CHAMBER 6. TOP FLUE CONNECTION
7. FLOW SWITCH
7. LOW NOX
�.
8. PUMPDOWN DELAY RELAY
DRAWN BY: KAP
CHECKED BY: MPD
HOT WATER UNIT HEATER SCHEDULE
DATE
F7
05
WATER SIDE AIR SIDE
ELECTRICAL OPER.
SCALE:
MANUFACTURER/
OUTPUT WPD EAT LAT
HP MOUNTING WT.
AS NOTED
JOB NUMBER
VV08007.00
CODE MODEL NO. SERVICE (MBH) GPM (FT) (" F) (" F) CFM (WATTS) VOLT PH HEIGHT (LBS) REMARKS
UH -1 STERLING HS -108A
MECHANICAL ROOM 6.8 0.8 0.8 60 90 210
16 (W) 115 1 8' -0" 50 A
SHEET INFORMATION:
GENERAL NOTES
MECHANICAL
1. EWT =180` F, LWT = 169 F
SCHEDULES
2. WATER CONTAINS 30% PROPYLENE GLYCOL.
3. JOB SITE ELEVATION = 8150 FT.
REMARK NOTES
A. PROVIDE WALL MOUNTED THERMOSTAT.
B. HORIZONTAL DISCHARGE W LOUVER.
"
FOR BUILDER PERMIT
SHEET NUMBER:
AND PRICING ONLY
M0.3
NOT FOR CONSTRUCTION
ISSUE / REVISIONS:
4 -15 -08 DD f PRELIMINARY PRICING SET
5 -5 -08 95% CD REVIEW SET
5 -16 -08 PERMIT SET
RADIANT SCHEDULE
MANIFOLD
CODE
ZONE
CODE
MANUFACTURER &
MODEL NO.
SERVICE
AREA
(SQ FT)
BTUH/
SQ FT
SURFACE
FINISH
TUBE
DIA
(IN)
TUBE
SPACING
(IN)
NUMBER
LOOPS
LOOP
LENGTH
GPM/
LOOP
GPM/
MANIFOLD
PD
(FT)
REMARKS
C
RZ -1
WIRSBO hePEX
201 Kitchen
173
19.08
CERAMIC TILE
1/2"
9
2
125
0.376
0.753
1.007
30% Propylene Glycol
SUCTION
RZ -2
WIRSBO hePEX
202 Dining Room
386
9.33
CARPET
1/2"
9
4
138
0,198
0.791
0.324
30% Propylene Glycol
RM -1
RZ -2
WIRSBO hePEX
203 Powder Room
38
5.26
CERAMIC TILE
1/2"
9
1
61
0.048
0.048
0.041
30% Propylene Glycol
COORDINATED ALL FRAME STYLES WITH CEILING SYSTEM FURNISHED, REFER TO ARCHITECTURAL DIVISION.
RZ -3
WIRSBO hePEX
204 Bedroom #
153
32.68
CARPET
1/2"
9
2
112
0.354
0.708
0.900
30% Propylene Glycol
RM -2
RZ -4
WIRSBO hePEX
205 Bath #
43
6.98
CERAMIC TILE
1/2"
9
1
67
0.075
0.075
0.046
30% Propylene Glycol
WATER HEATER
RZ -5
WIRSBO hePEX
206 Walk -In- Closet
60
6.67
CARPET
1/2"
9
1
90
0.100
0.100
0.061
30% Propylene Glycol
2"
RZ -5
WIRSBO hePEX
207 Master Bath
138
19.57
CERAMIC TILE
1/2"
9
2
102
0.323
0.645
0.491
30% Propylene Glycol
RM -3
RZ -6
WIRSBO hePEX
208 Master Bedroom
216
17.13
CARPET
1/2"
9
2
154
0.413
0.827
1.237
30% Propylene Glycol
RM -4
RZ -7
WIRSBO hePEX
209 Living Room
490
34.69
CARPET
1/2"
9
4
173
0.548
2.193
2.073
30% Propylene Glycol
1/8
RZ -8
WIRSBO hePEX
300 Bedroom #3
177
25.42
CARPET
1/2'
9
2
128
0.405
0.810
1.028
30% Propylene Glycol
RM -5
RZ -9
WIRSBO hePEX
301 Bath #3
33
21.21
CERAMIC TILE
1/2"
9
1
54
0.179
0.179
0.126
30% Propylene Glycol
RZ -10
WIRSBO hePEX
302 Bath #4
55
10.91
CERAMIC TILE
1/2"
9
1
83
0.145
0.145
0.057
30% Propylene Glycol
RM -6
RZ -11
WIRSBO hePEX
305 Bedroom #4
194
30.41
CARPET
1/2"
9
2
139
0.441
0.881
1.119
30% Propylene Glycol
RM -7
RZ -12
WIRSBO hePEX
304 Laundry/Landin2
133
27.82
CARPET
1 2"
9
2
98
0.312
0.624
0.475
30% Propylene GI col
HEAT EXCHANGER SCHEDULE
MANUFACTURER & TOTAL PRIMARY SIDE SECONDARY SIDE
CODE MODEL NO. SERVICE MBH EWT ('F) LWT ('F) GPM PD (FT) EWT ('F) LWT ('F) GPM PD (FT) REMARKS
HX -1 TRIANGLE TUBE TTP1 -14E SNOWMELT 35 180 160 3.6 1.4 100 130 2.4 0.5 30% PROPYLENE GLYCOL ON PRIMARY SIDE, 50% ON THE SECONDARY SIDE.
TUBE
Z MANUF • SURF ACE SP ACING : r i•r r r •,
C MODEL LOO r * r r
WIRSBO hePEX 507. PROPYLENE GLYCOL
GRILLE RE GISTER DIFFUSER SCHEDULE
NEATER SCHEDULE
PUMP
SCHEDULE
MANUFACTURER/
MANUFACTURER/
INLET SIZE
FACE SIZE
FRAME
MOUNTING
NOTES
A
B
C
MANUFACTURER/
CODE
MODEL NO.
SERVICE
HEAD
(IN)
NPSH
PUMP
VIBRATION ISOLATION
TYPE
ELECTRICAL
A
SUCTION
DIFFUSER
SUCTION
DISCHARGE
LOUVER FACE
NOTES
BBR -1
SURFACE
2
TYPE
STATIC DEFL.
HP
VOLT
PH
HZ
A
B
C
D
E
F
CODE
MODEL NO.
SERVICE
GPM
FT
RPM
FT
EFF.
YES NO
SIZE
SIZE
COORDINATED ALL FRAME STYLES WITH CEILING SYSTEM FURNISHED, REFER TO ARCHITECTURAL DIVISION.
P -1
TACO IL131
TOTAL STATIC PRESSURE SHALL NOT EXCEED: 0.10" WG FOR ALL DIFFUSERS, GRILLES AND REGISTERS, 0.05" WG FOR TRANSFER
BOILER
32.4
12
1725
2.9
-
-
-
1/3
120
1
60
NO
3"
3"
1
5
4
0
2
2
MATERIAL B. FINISH C. DAMPER D. ACCESSORIES
P -2
TACO IL120
1. ALUMINUM 1. OFF -WHITE 1. NONE 0. NONE
WATER HEATER
20.0
8
1725
45.5
-
-
-
1/6
120
1
60
C. ACCESSORIES
NO
2"
2"
1
5
4
0
2
2
1. INTEGRAL DAMPER AND
P -3
TACO IL113
2. 35% PROPYLENE GLYCOL
RADIANT FLOOR
8.8
12
1725
45.5
-
-
-
1/8
120
1
60
NO
3/4"
3/4"
1
5
4
0
2
2
P -4
TACO IL113
8. SINGLE TIER
HEAT EXCHANGER
3.6
12
1725
45.5
-
-
-
1/8
120
1
60
NO
3/4"
3/4"
1
5
4
0
2
2
P -5
TACO IL003
SNOWMELT
2.4
4
1725
45.5
-
-
-
1/33
120
1
60
NO
3/4"
3/4"
1
5
4
0
2
2
P -6
TACO IL003
BASEBOARD
2.0
5
1725
45.5
-
-
-
1/33
120
1
60
NO
3/4"
3/4"
1
5
4
0
2
2
GENERAL NOTES
1.
FOR PUMP WEIGHTS WITH INTERIA BASES, ADD 2 TIMES THE PUMP WEIGHT FOR THE INERTA BASE.
2.
PREMIUM EFFICIENCY MOTORS.
3.
FOR PARALLEL PUMP APPLICATIONS
MANUFACTURER SHALL REVIEW SINGLE PUMP OPERATON SUCH THAT PUMP CAN OPERATE
AND NOT EXCEED THE END OPERATION POINT ON THE PUMP CURVE AND MOTOR HP IS PROPERLY SELECTED TO PREVENT OVERLOADING.
4.
NPSHR AT SCHEDULED OPERATING POINT SHALL NOT EXCEED 0.8 TIMES NPSHA.
5.
REFER TO DRAWINGS TO DETERMINE
REQUIRED PUMP ROTATION. COORDINATE WITH MECHANICAL CONTRACTOR
PRIOR TO ORDERING.
6.
NON - OVERLOADING AT HORSEPOWER
CURVE UNLESS NOTED OTHERWISE.
NOTES
A.
FLUID
C. TYPE
E. DUTY
F. MISCELLANEOUS
0. WATER
1. CLOSE COUPLED BASE MOUNTED CETRIFUGAL
1. VFD, EPDM
COUPLER, INVERTER
DUTY MOTOR, CONTROLLER
1.
OPERATION AS SINGLE PUMP
IN PARALLEL ARRANGEMENT
1. 30% PROPYLENE GLYCOL
2. FLEXIBLE COUPLED BASE MOUNTED CENTRIFUGAL
2. CONSTANT SPEED
2.
PRIMARY /STANDBY OR SINGLE PUMP OPERATION
2. 35% PROPYLENE GLYCOL
3. IN -LINE, HORIZONTAL SHAFT CENTRIFUGAL
3. INJECTION PUMP
3.
PROVIDE SPARE MOTOR
3. 50% PROPYLENE GLYCOL
4. IN -LINE, VERTICAL SHAFT CENTRIFUGAL
4.
ALL BRONZE CONSTRUCTION
5. STEAM CONDENSATE RETURN
5.
DDC INTERFACE MODULE
B.
FLUID TEMPERATURE
6.
EMERGENCY POWER
1. 45' F
D. MOUNTING
7.
FLUSHED SINGLE TUNGSTEN CARBIDE SEAL WITH FILTER ON
2. 80' F
0. NONE
FLUSH LINE (CWS)
3. 110` F
1. NEOPRENE PADS
8.
ALL 316SS SHAFT, IMPELLER,
ALL WETTED PARTS,
TEFLON PACKING
4. 140' F
2. 4 POINT ISOLATORS
9.
FACTORY MOUNTED CONTROL
PANEL, WATER LEVEL
GAUGE, DIAL
5. 180` F
3. CONCRETE INERTIA BASE
THERMOMETER, DISCHARGE PRESSURE GAUGE, INLET STAINER,
STARTER ALTERNATOR
TUBE
Z MANUF • SURF ACE SP ACING : r i•r r r •,
C MODEL LOO r * r r
WIRSBO hePEX 507. PROPYLENE GLYCOL
i
i
i
ui
i
i
R 0
00
CO 0
M
Z C)
C �.
tS l
kA
1214 t
DRAWN BY: KAP
CHECKED BY: u MPD
DATE: 05116/08
SCALE: AS NOTED
JOB NUMBER: VV08007.00
SHEET INFORMATION: �r
MECHANICAL
SCHEDULES
SHEET NUMBER:
GRILLE RE GISTER DIFFUSER SCHEDULE
NEATER SCHEDULE
MANUFACTURER/
MANUFACTURER/
INLET SIZE
FACE SIZE
FRAME
MOUNTING
NOTES
A
B
C
D
CODE
MODEL NO.
SERVICE
(IN)
(IN)
STYLE
TYPE
SERVED
TYPE
EWT (' F)
A
TITUS 350RL
EXHAUST
SEE PLANS
-
LOUVER FACE
1
BBR -1
SURFACE
2
1
1
0
1
SEE PLANS
1
1
3/4"
1
3
0
2
GENERAL NOTES
1.
REFER TO REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED AIR DEVCES.
2.
COORDINATED ALL FRAME STYLES WITH CEILING SYSTEM FURNISHED, REFER TO ARCHITECTURAL DIVISION.
3.
TOTAL STATIC PRESSURE SHALL NOT EXCEED: 0.10" WG FOR ALL DIFFUSERS, GRILLES AND REGISTERS, 0.05" WG FOR TRANSFER
GRILLES.
4.
NC VALUES SHALL BE A MAXIMUM OF 25. BASED UPON ROOM ABSORPTION RATE OF 10db, RE 10" -12 WATTS.
5.
SEE PLAN FOR NECK SIZES NOT CALLED OUT IN SCHEDULE.
6.
CEILING DIFFUSERS 4 -WAY BLOW UNLESS NOTED OR REQUIRED.
1. CAPACITIES AT 8150 FT ELEVATION.
7.
CEILING RADIATION OR FIRE /SMOKE DAMPER AND RATED BLANKET WHERE SHOWN OR REQUIRED.
8.
ALL DIFFUSERS IN LOCKER ROOMS SHALL BE ALUMINUM.
9.
PROVIDE TRIM OPTION FOR LAY -IN DIFFUSERS USED IN SURFACE MOUNT APPLICATIONS.
3. VERIFY EXACT LENGTH OF RADIATION REQUIREMENTS WITH ARCHITECTURAL WALL LIMITATIONS.
NOTES:
A.
MATERIAL B. FINISH C. DAMPER D. ACCESSORIES
1. ALUMINUM 1. OFF -WHITE 1. NONE 0. NONE
5. COORDINATE SUPPLY /RETURN PIPING CONNECTIONS WITH FLOOR PLANS AND FIELD CONDITIONS.
2. STEEL 2. CLEAR ACRYLIC 2. OBD 1. MINIMUM LIMIT STOP
3. PLASTIC 3. MILL 2. HONEY COMB EQUALIZER GRID
IN NECK FULL LENGTH OF SLOTS
4. COLOR BY ARCHITECT 3. 90' SECTORIZING BAFFLES FOR
1, 2 OR 3 WAY BLOW
i
i
i
ui
i
i
R 0
00
CO 0
M
Z C)
C �.
tS l
kA
1214 t
DRAWN BY: KAP
CHECKED BY: u MPD
DATE: 05116/08
SCALE: AS NOTED
JOB NUMBER: VV08007.00
SHEET INFORMATION: �r
MECHANICAL
SCHEDULES
SHEET NUMBER:
HYDRONIC BASEBOARD
NEATER SCHEDULE
MANUFACTURER/
AREA
BTU /HR
HEATING ELEMENT
TUBE
NOTES
A
B
C
D
CODE
MODEL NO.
SERVED
/FT
EWT (' F)
LWT (' F)
GPM
LENGTH (IN)
ROWS
TIERS
SIZE
BBR -1
STERLING SENIOR SR- 3/4 -60
SEE PLANS
507
180.0
160
1
SEE PLANS
1
1
3/4"
1
3
0
2
GENERAL NOTES
1. CAPACITIES AT 8150 FT ELEVATION.
2. PROVIDE ALL CORNERS, TRIM PANELS, END PANELS, ETC. FOR COMPLETE ENCLOSURE ASSEMBLY.
3. VERIFY EXACT LENGTH OF RADIATION REQUIREMENTS WITH ARCHITECTURAL WALL LIMITATIONS.
4. COPPER TUBES, ALUMINUM FINS.
5. COORDINATE SUPPLY /RETURN PIPING CONNECTIONS WITH FLOOR PLANS AND FIELD CONDITIONS.
NOTES
A. FLUID
H. CABINET STYLE
C. ACCESSORIES
D. FRONT
GAGE STEEL
0. WATER
1. PEDESTAL MOUNTED
0. NONE
1. 14
GA.
1. 30% PROPYLENE GLYCOL
2. FREE STANDING
1. INTEGRAL DAMPER AND
2. 16
GA.
2. 35% PROPYLENE GLYCOL
3. WALL HUNG
CONTROL KNOB
3. 18
GA.
3. 50% PROPYLENE GLYCOL
4. SLOPED TOP
2. INTEGRAL DAMPER AND
5. FLAT TOP
HEX HEAD OPERATOR
6. STAMPED STEEL
3. LOCKING ACCESS DOOR
7. EXTRUDED ALUMINUM
4. STANDARD ACCESS DOORS
8. SINGLE TIER
9. DOUBLE TIER
i
i
i
ui
i
i
R 0
00
CO 0
M
Z C)
C �.
tS l
kA
1214 t
DRAWN BY: KAP
CHECKED BY: u MPD
DATE: 05116/08
SCALE: AS NOTED
JOB NUMBER: VV08007.00
SHEET INFORMATION: �r
MECHANICAL
SCHEDULES
SHEET NUMBER:
ISSUE / REVISIONS:
4 -15-08 DD / PRELIMINARY PRICING SET
Zi �7, KEY NOTES$ 5 -5-08 95% CD REVIEW SET
-Y4" RFS & RFR TO RADIANT FLOOR 5-16-08 PERMIT SET
MANIFOLD.
I ! „
? -Y4 HWS & HWR TO HOT WATER
( ;
BASEBOARD. SEE BOILER PIPING DIAGRAM
FOR CONTINUATION.
! 9 a 1 HWS & HWR TO FLOOR BELOW.
I
F4 1 HWS & HWR UP TO MECHANICAL ROOM.
i I1�lj I C ,! % =m i . Kt.(UKN 1"""'1'-%1 PrIn1.4" '
Q FT SQ FT i `,� 1 � i RM SERVING RADIANT
TELESTAT MANIFOLD RET 1 RZ I- i SUPPLY Z 4 0 LOOPS TOTAL)
SERVING RADIANT �-- ' i _ { 4 1 i t'J
ZONES 3 & 4
(3 LOOPS TOTAL) SUP 1 f i 1 1 j w s' !
�
3 BEDROOM i I 110
2 i i i ! t_______SI ; 490
SQ FT
r� r
1
- - U
--UH
lQj hhtt vf
LA a .t
sa
t
J
--UG �o ne ��o
r�mi3
I
P
i
2A
i
3B
3C
NORTHI
MECH P I P ING P LAN r�
SCALE: 1/4
5A
i
$ } { i
} S
I
5B
F OR B PE R MIT
I SHEET NUMBER:
AND PR ICING ONLY
. r C
GENERAL NOTES
1. ALL RECTANGULAR DUCTWORK DIMENSIONS
ARE INSIDE TO INSIDE UNLESS OTHERWISE
NOTED.
2. PROVIDE BACKDRAFT DAMPERS ON ALL
BATHROOM EXHAUST FANS.
3. COORDINATE STYLE AND LOCATION OF ALL
EXTERIOR LOUVERS AND WALL CAPS WITH
THE ARCHITECT.
KEY i
Ell 6"0 EXHAUST DUCT UP THRU ROOF TO
ROO w
2l 4"0 DRYER VENT UP THRU ROOF TO ROOF
CAP.
3l 4 "0 COMBINATION AIR INTAKE j FLUE
EXHAUST UP THRU ROOF TO ROOF
TERMINATION KIT.
ISSUE / REVISIONS:
4 -15-08 DD / PRELIMINARY PRICING SET
5 -5 -08 95% CD REVIEW SET
5 -16 -08 PERMIT SET
i
t
1
•
t
LIJ
m Lo
.•
•
i. !
0
C
w�►
V ;,
;^,`
�
i
J � •
DATE: 05/16/08
SCALE: AS NOTED
JOB NUMBER: VV08007.00 I
1 THIRD FLOOR MECH
M2.3 I SCALE: 1/4"=l'-O"
0 .
s
SHEET INFORMATION:
THI RD FL OO R
MECH
XJIXCLli . A a
SHEET NUMBER:
ISSUE / REVISIONS:
415 -08 DD / PRELIMINARY PRICING
SET
MANIFOLD SUPPORT-
MANIFOLD
SUPPORT-
5 -5-08 95% CD REVIEW SET
BRACKET (TYP)
BRACKET
(TYP)
5 -18 -08 PERMIT SET
VALVE
CAP
ANGLE VALVES (TYP)
MULTITHERM 2 -WAY
ZONE CONTROL VALVE
12" MIN ABOVE SNOWLINE. 24" MAX
END CAP rn
W/ VENT
m m
RETURN MAIN
END CAP-,
Wj ENT
C ("�) r owao' ) rmmm)
RETURN MAIN
ROOF FLASHING AND
BOOT PROVIDED BY
INSTALLER
RETURN
MANIFOLD
RETURN MANIFOLD
SUPPORT ASSEMBLY SECURELY
(BY INSTALLER). DO NOT DRILL
\ ACCU
\ ACCU
OR SCREW INTO THE VENT OR
DRAIN DOWN
DRAIN DOWN
AIR PIING OR FITTINGS.
SETTER HOSE BIB
SETTER HOSE BIB
SETTER
CONCENTRIC VENT /AIR
ASSEMBLY
L
END CA COMPRESSION
FITTING (TYP)
5 /s "� LOOP
RETURN PIPING SUPPLY
BY -PASS
COMPRESSION %'? LOOP
FITTING (TYP) RETURN PIPING
SUPPLY
ELBOW AND AIR PIPING
BY INSTALLER
Wj VENT
(TYP) MAIN
PIPE
(TYP)
MAIN
_
6J
rc:h
rc:h
z T
SUPPLY
MANIFOLD
SUPPLY MANIFOLD
VENT PIPING AIR PIPING
U)
(BY INSTALLER) (BY INSTALLER)
W Q
C) CL
DRAIN DOWN
DRAIN DOWN
[ BALL
%%_01
�
HOSE BIB
HOSE BIB
Lo
ALL
�`/ �
co
VALVE
COMPRESSION
COMPRESSION
VALVE
,/
co
FITTING (TYP)
„
r� ? LOOP
FITTING (TYP)
1/2"'?
, LOOP
uj
T
O
SUPPLY PIPING (TYP)
SUPPLY PIPING (TYP)
CONCENTRIC TERMINATION DETAIL
o
1
M3.1 NO SCALE
co
O
co
6 SNOWMELT MANIFOLD DETAIL
3 RADIANT FLOOR MANIFOLD DETAIL
Z
M3.1 NO SCALE
M3.1 NO SCALE
Z
0 _ J
o
W
w
ASSEMBLY COMPONENTS:
TO SYSTEM
Q
T
MOLDED POLYETHYLENE STORAGE DRUM 50 GALLON CAPACITY ON
SHUTOFF VALVE`
STEEL STAND WITH INTEGRAL PUMP PLATFORM. PROVIDE
REMOVABLE LID, BRAZED 3/4 INCH OUTLET LOCATED 3 INCHES
— PRESSURE SWITCH (ON 10 PSIG, OFF 12 PSIG)
CIRCUIT SETTER
—�
ABOVE BOTTOM OF TANK AND 3/4 INCH OUTLET WITH DRAIN VALVE
FLOW SWITCH. ALARM
HePEX TUBING
FS
SPACED 9" O.C.
NEAR BOTTOM OF TANK. POSITIVE DISPLACEMENT ROTARY GEAR
TO BAS SYSTEM
TYPE FEEDER PUMP, ALL BRONZE CONSTRUCTION, BUILT IN RELIEF
PROVIDE PUMP SUPPORT
AT INLET & DISCHARGE
2" MIN. WIRE TIE 3' 0. C.
VALVE ADJUSTABLE BETWEEN 30 PSI AND 50 PSI AND 3/8" PIPE
CONNECTIONS. CAPACITY OF 1.5 GPM AT 100 PSI, 1750 RPM, 15
PRV
PRESSURE GAUGE c�
W GAGE COCKS
PIPING - DO NOT SUPPORT
CONCRETE SEE FIGURE 2
SET 12 PSI
PUMP MOTOR
COVER
AMP, 115/60/1. OBERDORFER MODEL 991 RMVSF OR DRESSER,
D
PULSAFEEDER KING.
PROVIDE START STOP PRESSURE SWITCH FOR PUMP CONTROL.
TOP OF TURIN
FURNAS MODEL 69WB3. (3 -35 PSIA) PROVIDE 30 SECOND DELAY
NC
TO BE WITHIN
ON PUMP START.
TRANSLUCENT STORAGE
25� OF SLAB
PROVIDE DUAL POINT LIQUID LEVEL SWITCH ASSEMBLY, WITH DRY
PRESSURE GAUGE Wj
DRUM WITH LID
DEPTH
ea a 4 q
CONTACTS FOR DDC ALARM LIQUID METRONICS MODEL 26731, 115
NEEDLE GLOBE VALVE f
1 /2 DRAIN
IN -LINE
PUMP
Q . d d a
COMPACTED
VOLT, 1 PHASE, 60 HZ, 6 AMP LOAD MAX WITH LOW WATER
W /BUFFER
BASE
CUTOFF SWITCH TO STOP PUMP WHEN WATER LEVEL REACHES 3
GRADE
INCHES (ADJUSTABLE) ABOVE OUTLET SUPPLY FITTING IN STORAGE
AIR GAP
DRUM. PUMP SHALL BE PROVIDED WITH A CURRENT SWITCH TO
GLOBE VALVE
ALARM DDC SYSTEM WHEN PUMP IS RUNNING MORE THAN 3
W /BUFFER --^
'°
MINUTES.
LOW WATER CUT -OFF
2" HIGH DENSITY RIGID
CONTROLS IN NEMA 7X ENCLOSURE MOMENTARY SPRING LOADED
SPRING CHECK PUMP
~"�'`"~--
SWITCH. ALARM TO
UNION OR
BOARD UNDER
BAD I
PUSH BUTTON FOR PUMP OPERATION TEST.
BAS SYSTEM.
►- FLANGE
�.
CONNECTION
DRIVEWAY. USE STANDARD
PROVIDE A FILL SYSTEM AND T OF STORAGE DRUM W{TH A
P/T TEST 4"
PLUGS
°-
SHUTOFF VALVE
DENSITY UNDER DECKS.
v.
'
MAX-TURE OF 30% PROPYLENE GLYCOL/ 70% WATER SOLUTION FOR
HEATING SYSTEM, PROPYLENE GLYCOL INDUSTRIAL QUALITY HEAT
TRANSFER FLUID, DOW CHEMICAL "DOWFROST ". CONTRACTOR TO
I I I
°
CALCULATE SYSTEM VOLUME BASED ON ACTUAL PIPE ROUTES. ALL
FLOOR
Ci
RIGID PIPE TYPE L COPPER.
f
x "-
ABOVE ASSEMBLY SHALL BE ADVANTAGE CONTROLS AGF -1,
STRAINER _
EQUIVALENT SUBSTITUTE IS NEPTUNE G -50 -1 A -RC GMP IF SYSTEM
MEETS ABOVE SPECIFICATION.
DRAIN VALVE WITH HOSE CONNECTION
a
) VERTICAL IN -LINE
PUMP DIAGRAM
GLYCOL FEEDER ASSEMBLY DIAGRAM
F
w
7
M3,1 NO SCALE
M3,1 N SCALE
TIE WRAP TO CONCRETE
'fix
REINFORCING
REVERSE RETURN LAYOUT
T
�4 ......... �T4i�
r po Fie 'r
C).
aa
Q i
,-
337 9
• q
MANUAL AIR VENT
�..
PROVIDE ARMIFLEX INSULATION SLEEVES
— 4" � ALL THREAD
1/4"
AT ALL EXPANSION JOINTS IN THE CONCRETE
STEEL HANGER RODS
PRESSURIZE SNOW MELT TUBING TO 100 PSI
ACCESS PANEL,(TYP.)
--- EXHAUST DUCT ,SIZE
AIR TO PREVENT CRUSHING OF TUBE WHEN
f 'I --
AS INDICATED ON PLANS
�l
THE CONCRETE IS POURED
DRAWN BY: KAP
ADJUSTABLE SELF - CONTAINED
t -
CHECKED BY: MPD
CONTROL VALVE: "DANFOSS"
CEILING l �
FLEXIBLE DUCT CONN.
#RAV OPERATOR W /VALVE MTD.
DATE: 0 X16 8
DIAL & REMOTE SENSOR.
- -. - -,
P & T TEST PLUG
SCALE. AS NOTED
_ ENCLOSURE
GRILLE
HWR
I I � �)
FINISHED FLOOR
JOB NUMBER:
_ 1 1 1 1 1 1 1 1! L- J
VV08007.00
MANUAL SHUT -OFF VALVE COMBINATION BALANCING
SNOWMELT TUBING DETAIL
SHEET INFORMATION:
HEATING ELEMENT & SHUT -OFF VALVE.
2
MECHANICAL
UNION,(TYP.)
M3.1 NO SCALE
DETAILS
CEILING FAN
DIAGRAM
5
M3.1 NO SCALE
('; TYPICAL BASEBOARD
DIAGRAM
M3.1 NO SCALE
FOR BUILDER PERMIT
SHEET NUMBER:
AND PRICING ONLY
M3.1
NOT FOR CONSTRUCTION
• # R
1. THE GENERAL PLUMBING REQUIREMENTS ON SHEET P0.1 PERTAIN TO THE WORK
OF THIS DIVISION.
2. PREPARE SHOP DRAWINGS OF ALL NEW WORK (INCLUDING SLEEVE LOCATIONS)
TO VERIFY LOCATIONS AND COORDINATION OF WORK BETWEEN TRADES PRIOR
TO INSTALLATION.
3. ALL DRAIN GRATES, CLEANOUT COVERS, AND OTHER FINISHED, EXPOSED
COMPONENTS SHALL BE PROTECTED FROM DAMAGE. DAMAGED COMPONENTS
SHALL BE REPLACED BY CONTRACTOR AT NO ADDITIONAL COST TO THE
CONTRACT.
4. HORIZONTAL SANITARY PIPING IN CEILING SHALL RUN AT A SLOPE OF 1/4" PER
FOOT MINIMUM FOR 3" AND SMALLER PIPING. 4" AND LARGER PIPING SHALL RUN
AT 1/8" PER FOOT MINIMUM.
5. NO DOMESTIC WATER LINES SHALL BE LOCATED EXPOSED IN FINISHED SPACES
OR BELOW THE BUILDING SLAB UNLESS SHOWN OTHERWISE ON THE DRAWINGS.
6. IN ADDITION TO THE CLEANOUT LOCATIONS SHOWN ON DRAWINGS, PROVIDE
ADDITIONAL CLEANOUTS AT:
A. EACH RUN OF PIPING WHICH IS MORE THAN 100 FEET IN LENGTH OR
FRACTION THEREOF.
B. HORIZONTAL LINES FOR EACH AGGREGATE CHANGE OF DIRECTION
EXCEEDING 135 DEGREES.
C. AT THE BASE OF ALL WASTE AND VENT RISERS. ALL VERTICAL CLEANOUTS
SHALL BE SIZED TO ACCOMMODATE THE LARGEST PIPE ON THAT BRANCH
LINE, BUT NEVER LARGER THAN 4".
7. NO GAS LINES SHALL BE LOCATED BELOW BUILDING SLAB. ALL GAS PIPING IN AIR
PLENUMS TO BE WELDED
8. PROVIDE ISOLATION VALVES ON ALL PIPING SERVING HOSE BIBBS.
9. MAINTAIN DESIGNATED PLUMBING FIXTURE HEADER SIZE FOR FULL BANK OF
FIXTURES.
10. PROVIDE GAS VENTS EXTENDING CONTINUOUSLY FROM ALL INTERIOR GAS
REGULATORS TO THE EXTERIOR OF THE BUILDING. TERMINATE AT AN APPROVED
LOCATION. SIZE VENTS SUCH THAT MINIMUM VENT SIZE (FOR VENT WHICH IS 10
FEET OR LESS IN LENGTH) EQUALS RELIEF OUTLET PIPE SIZE. INCREASE VENT
PIPE SIZE ONE PIPE SIZE FOR EVERY ADDITIONAL TEN FEET OF VENT PIPE
LENGTH.
A. PROVIDE AN ISOLATION VALVE DOWNSTREAM OF EVERY INTERIOR GAS
REGULATOR.
• -
A. PIPE INSTALLATION:
(1) ALL PIPING SHALL BE ADEQUATELY SUPPORTED FROM THE BUILDING
STRUCTURE TO PREVENT SAGGING, POCKETING, SWAYING OR
DISPLACEMENT BY MEANS OF HANGERS AND SUPPORTS. PIPING IS NOT
TO BE SUPPORTED BY EQUIPMENT.
(2) PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR MATERIALS.
(3) PROVIDE MANUAL AIR VENTS AND CAPPED HOSE -END DRAINS WITH
ISOLATION VALVES AT PIPING HIGH AND LOW POINTS.
(4) WELD PIPE IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS.
WELDERS SHALL BE CERTIFIED FOR TYPE OF WORK BEING PERFORMED.
(5) FLUSH OUT PIPING AND REMOVE CONTROL DEVICES BEFORE
PERFORMING PRESSURE TEST. DO NOT USE PIPING SYSTEM VALVES TO
ISOLATE SECTIONS WHERE TEST PRESSURE EXCEEDS VALVE PRESSURE
RATING. PRESSURIZE PIPING AT 100 PSIG. IF LEAKAGE IS OBSERVED OR
IF TEMPERATURE COMPENSATED PRESSURE DROP EXCEEDS 1% OF
TEST PRESSURE, REPAIR LEAKS AND RETEST.
(6) PLASTIC PIPE: AIR PRESSURE TEST ALL PLASTIC PIPE AND PEX PIPE
SYSTEMS ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
a. DO NOT USE AIR PRESSURE TO TEST PVC OR CPVC PIPE.
(7) ALL STRAINERS SHALL BE FURNISHED WITH A"ROUGHING" SCREEN AND
TWO (2) SCREENS FOR NORMAL OPERATION, INSTALL STRAINER WITH
ROUGHING SCREEN AND OPERATE SYSTEM FOR 24 HOURS MINIMUM
(RUN DOMESTIC WATER SYSTEMS AT MAX FLOW FOR A MINIMUM OF ONE
HALF (1/2) HOUR. REMOVE ROUGHING SCREEN AND INSTALL NORMAL
SCREEN, AFTER TWO WEEKS OF NORMAL OPERATION INSTALL NEW
NORMAL SCREEN.
(1) DOMESTIC WATER, SIZE 3 AND UNDER:
a. PIPE: COPPER TUBE, HARD TEMPER, TYPE L.
b. FITTINGS: WROUGHT COPPER, OR CAST BRONZE.
c. SOLDER: 95-5 TIN- ANTIMONY.
d. WATER PIPING CAN ALSO BE WIRSBO AQUAPEX APR, REHAU
RAUPEX OR APPROVED EQUIVAANT.
(2) SOIL AND VENT PIPING, ALL SIZES:
a. ABOVE GROUND: ANY OF THE FOLLOWING:
(i) CAST IRON HUB AND SPIGOT, NEOPRENE GASKET.
(ii) CAST IRON NO HUB, NEOPRENE GASKET AND STAINLESS STEEL
SLEEVE JOINT.
(iii) DWV COPPER WITH DWV FITTINGS, SOLDER JOINT.
(iv) ABS PIPE, ABS SOCKET FITTINGS, AND SOLVENT - CEMENTED
JOINTS.
(v) PVC PIPE, PVC SOCKET FITTINGS, AND SOLVENT - CEMENTED
JOINTS.
b. COUPLINGS SHALL BE HEAVY DUTY, ALL STAINLESS STEEL: 3" WIDE
304 STAINLESS STEEL SHIELD; (4) MINIMUM STAINLESS STEEL
CLAMPS; FIXED AND "FLOATING" EYELET.
(i) TORQUE TO MINIMUM 30 INCH POUNDS PER MANUFACTURER'S
RECOMMENDATION.
(ii) HUSKY SERIES 4000 OR EQUIVALENT BY CLAMP -ALL.
(3) GAS PIPING:
a. SIZE 2" AND SMALLER: SCHEDULE 40 STEEL WITH 150 PSI CAST -IRON
THREADED FITTINGS.
b. SIZE 2 -1/2" AND LARGER: SCHEDULE 40 STEEL WITH STANDARD
WROUGHT, BUTT WELDED FITTINGS.
12. MECHANICAL INSULATION:
A. MATERIALS:
B. (P /SL) REFER TO BULLETIN 173 (DATED JULY 23, 1991) FOR REQUIRED TYPE
AND THICKNESSES.
(1) SEAL ALL PIPING WHICH IS NORMALLY COLDER THAN AMBIENT WITH
VAPOR BARRIER RATED MASTIC.
(2) TYPE A: FIBERGLASS PIPE INSULATION WITH SELF ADHESIVE ALL
SERVICE VAPOR BARRIER JACKET. FITTINGS INSULATED WITH
FIBERGLASS INSERTS IN PVC FITTING COVERS. ALL MATERIALS FLAME
SPREAD 25, SMOKE DEVELOPED 50.
(3) TYPE B: FLEXIBLE ELASTOMERIC CLOSED CELL PIPE INSULATION, FLAME
SPREAD 25, SMOKE DEVELOPED 50.
(4) TYPE C: FLEXIBLE FIBERGLASS BLANKET WITH REINFORCED
KRAFT /ALUMINUM FOIL VAPOR BARRIER FACING.
(5) TYPE D: SEMI -RIGID FIBERGLASS BOARD WITH REINFORCED VAPOR
BARRIER FACING, 3 LBS /CU.FT. DENSITY.
(6) TYPE E: FIBERGLASS BONDED TO FLEXIBLE ALL SURFACE JACKET.
FIBERGLASS SLIT OR ORIENTED TO ALLOW CONFORMANCE TO ROUND
SURFACES. DENSITY 3 LBS /CU.FT.
C. APPLICATION:
(1) ABOVE GROUND DOMESTIC COLD WATER.
a. ALL SIZES, 1/2" THICK TYPE A ORB.
(2) ABOVE GROUND DOMESTIC HOT WATER.
a. LESS THAN 2 -1/2" -1 " THICK TYPE A OR B.
b. 2 -1/2 " AND GREATER - 1 -1/2" THICK TYPE A ORB.
(3) EQUIPMENT.
a. HOT WATER STORAGE TANK. 2" THICK TYPE E.
(4) REPAIRS TO EXISTING SYSTEMS.
a. MATCH MATERIAL AND THICKNESS AS CLOSE AS POSSIBLE.
(5) HEAT TRACE.
a. INSTALL INSULATION OVERHEAT TRACE CABLE FOR ENTIRE LENGTH
OF PIPE INSTALLED OUTSIDE OF BUILDING.
FIRE PROTECTION NOTES
13. THE FIRE SPRINKLER CONTRACTOR SHALL SERVE AS THE ENGINEER OF RECORD
FOR ALL WORK PERFORMED UNDER THIS DIVISION. SUBMIT COMPLETE FIRE
SPRINKLER SYSTEM SHOP DRAWINGS, GENERATED BY CONTRACTOR, IN
ACCORDANCE WITH DENVER DEPARTMENT OF PUBLIC WORKS AND DENVER FIRE
DEPARTMENT REQUIREMENTS. SHOP DRAWINGS SHOULD BE A MINIMUM 1/8"
SCALE, SHOW DEVICE AND APPLIANCE LOCATIONS, BUILDING BACKGROUND
INFORMATION, ROOM OCCUPANCY DESCRIPTIONS, DOOR SWINGS AND FIRE
PROTECTION SYSTEM LAYOUT AND DETAILS. SHOP DRAWINGS SHALL BE
SEALED, OR SUBMITTED WITH A LETTER SEALED BY A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE OF COLORADO. THE PROFESSIONAL ENGINEER
SHALL BE EMPLOYED DIRECTLY BY, OR BE A SUBCONSULTANT TO THE FIRE
SPRINKLER CONTRACTOR. SUBMIT SHOP DRAWINGS AND HYDRAULIC
CALCULATIONS TO THE BUILDING INSPECTIONS DIVISION AND FIRE PREVENTION
BUREAU FIRST, AND OBTAIN THEIR APPROVAL BEFORE SUBMISSION TO THE
ARCHITECT.
14, THE ENTIRE BUILDING SHALL BE SERVED BY A WETPIPE TYPE FIRE SPRINKLER
SYSTEM. COORDINATE ELECTRICAL, FIRE PROTECTION AND MECHANICAL SPACE
REQUIREMENTS CAREFULLY BEFORE PROCEEDING WITH INSTALLATION.
SYSTEM SHALL BE INSTALLED COMPLETE AND OPERATIONAL, INCLUDING WATER
FLOW INDICATOR, CONNECTIONS TO EXISTING ALARM, DRAIN PIPING,
IDENTIFICATION SIGNS, ETC.
15. WORK SHALL BE PERFORMED BY A QUALIFIED FIRE SPRINKLER INSTALLER WITH
A MINIMUM OF (5) FIVE YEARS EXPERIENCE IN SIMILAR INSTALLATIONS.
16. COORDINATE ALL WORK WITH ALL OTHER TRADES.
PLUMBING LEGEND
{ NOT ALL SYMBOLS LISTED BELOW ARE BEING USED IN THIS SET OF PLUMBING DRAWINGS )
SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION
MEDICAL FITTINGS: SYMBOLS:
—MA MA MEDICAL AIR 0--- ELBOW UP F SECTION NO.
4( M
SECTION VIEW
0 0 OXYGEN c ELBOW DOWN SHEET NO.
— VAC VAC VACUUM TEE UP
rF DETAIL
M1 DESIGNATION
NO NO NITROUS OXIDE V TEE DOWN
0 G NAT. GAS OUTLET PIPE CAP OR
PLUG F
1 EQUIPMENT
----11110. 0 OXYGEN OUTLET ---- GC GAS COCK F DESIGNATION
1
---q V VACUUM OUTLET -) CO CLEANOUT PLUG
°--0 MA MEDICAL HB HOSE BIBB, SHEET KEY NOTES
AIR OUTLET WH WALL HYDRANT ` T K
POINT OF CONN.
- ----{� MA MED AIR OUTLET ---- VB VACUUM BREAKER POC (CONN. NEW TO
EXISTING
SPRINKLER @ RD ROOF DRAIN POD ADS DISCONNECTION
EXISTING SPRINKLEF OVERFLOW __,,,,, _ ARROW INDICATES
HEAD TO REMAIN @ OD ROOF DRAIN DIRECTION OF FLOW
EXISTING SPRINKLER DOWNSPOUT UP RISE IN DIRECTION
HEAD TO RELOCATED DSN NOZZLE OF FLOW
EXISTING DN_ DROP IN DIRECTION
SPRINKLER HEAD SHOCK ARRESTOR
TO NEW LOCATION SA W /BALL VALVE OF FLOW
NEW SPRINKLER
A HEAD TO MATCH E) FD FLOOR DRAIN lllo� TB THRUST BLOCK
EXISTING
DN DOWN
PIPING: AD AREA DRAIN
-- (E) -- (E) EXISTING PIPING � AFF ABOVE FIN. FLOOR
AFG ABOVE FIN. GRADE
MUM EXISTING PIPING a FCO FLOOR CLEANOUT TOP TOP OF PIPE (AFF)
TO BE REMOVED
CW DOMESTIC �i WCO WALL CLEANOUT BOP BOT, OF PIPE (AFF)
CW COLD WATER I.E. INVERT ELEVATION
DOMESTIC
HW HW HOT WATER JIL VTR VENT THRU ROOF NTS NOT TO SCALE
___T— T TEMPERED WATER VALVES: (E) (E) EXISTING
DOMESTIC HOT GV GATE VALVE (N) (N) NEW
—HWC HWC WATER CIRCULATING OUTSIDE STEM AND (R) (R) REMOVE OR
SANITARY WASTE OS &Y YOKE RELOCATE
—SAN SAN ABOVE FLOOR
- SANITARY WASTE — DV DRAIN VALVE W/
--SAN-- SAN BELOW FLOOR HOSE END CONN.
- - GW -- - - GW GREASE WASTE BALL VALVE W/
BELOW FLOOR HOSE CONNECTION
___V___ V SANITARY VENT CHECK VALVE WITH
CV INDICATION OF FLOW
STORM PIPING N DIRECTION
s ST _ ST ABOVE FLOOR
PRESSURE
STORM PIPING PRV REDUCING VALVE
ST__ ST BELOW FLOOR
STORM OVERFLOW rs � J SV SOLENOID VALVE
_ OD— ABOVE FLOOR
STORM OVERFLOW FC AUTO FLOW CONTROL
--OD-- OD BELOW FLOOR FCV VALVE W/ TEST
PORTS
G G NATURAL GAS CIRCUIT SE17ER OR
F F FIRE Q CS,BV BALANCING VALVE
— DR DR EQUIP. DRAIN GLOBE VALVE
A A COMPRESSED AIR GLV (STRAIGHT
PATTERN
PIPE SIZE
—SAN PIPE TYPE GLV GLOBE VALVE
(ANGLE PATTERN)
-- �� i--- BFV BUTTERFLY
VALVE
FITTINGS: -{-- BV BALL VALVE
EJ EXPANSION AUTOMATIC
- limp EJ JOINT � TCV TEMP. CONTROL
VALVE 2 -WAY
AUTOMATIC
U UNION TCV TEMP. CONTROL
VALVE 3-WAY
PV PLUG VALVE
THERMOMETER
W /THERMOWELL IPR TEMPERATURE/
PRESSURE
RELIEF VALVE
AV AIR VENT VALVE IN RISER
-��- FC FLEXIBLE PIPE STRAINER W/
CONNECTOR BLOW -OFF
STIR & CAPPED HOSE -
FS FS FLOW SWITCH END CONNECTION
1� ps PS PRESSURE STEAM TRAP
SWITCH
l PRESSURE
PG GAUGE W /GAUGE
COCK
FOR BUILDER PERMIT
AND PRICING ONLY
NOT FOR CONSTRUCTION
ISSUE / REVISIONS:
4 -15-08 DD / PRELIMINARY PRICING SET
5 -5-08 95% CD REVIEW SET
5 -18-08 PERMIT SET
t
i
ui
•
•
o
.•
t
i
LLJ
0
CJ A
w Cr
CT
cA
A.
LA 4A o
s.m n
�V
�
•
w
kffl�
DRAWN BY:
KAP
CHECKED BY:
MPD
DATE:
05/16/08
SCALE:
AS NOTED
JOB NUMBER:
VV08007.00
V,HEET INFORMATIO
PLUMBING r:
SPECIFICATIONS
SHEET NUMBER:
ISSUE / REVISIONS:
4 -15 -08 DD / PRELIMINARY PRICING SET
5 -5 -08 95% CD REVIEW SET
5 -16 -08 PERMIT SET
PLUMBING
FIXTURE SCHEDULE
CODE
FIXTURE
DESCRIPTION
LOCATION
CW CONN.
I HW CONN.
I SAN. CONN.
VENT CONN.
MANUFACTURER & MODEL NO.
FAUCE /FLUSH VALVE
REMARKS
WC -1
WATER CLOSET
PLUMBING FIXTURE SPECIFICATIONS
AND HARDWARE SELECTION TO BE
L -1
LAVAT
BY THE INTERIOR DESIGNER. FIXTURE
ALLOWANCE NOT TO EXCEED
THE ESTABLISHED BUDGET.
KS -1
KITCHEN SINK
BT -1
BATHTUB
w
^
_
z W
W
0 _
SH -1
SHOWER
WASHER BOX
-
LAUNDRY
1 /2"
1 /2"
2"
1 -1 /2"
GUY GRAY T200
-
FD -1
FLOOR DRAIN
-
GENERAL FLOOR DRAWS
SIZES AS NOTED
ZURN Z- 415 -P -VP WITH "- ZB -6B" STRAINER
-
D.C.C.I. BODY, POLISHED BRONZE GRATE, W/ TP -1
AD -1
AREA DRAIN
-
NEW DECK
SIZES AS NOTED
ZURN Z- 154 -ZB -VP
-
D.C.C.I BODY WITH HEEL PROOF POLISHED BRONZE GRATE
TP -1
TRAP PRIMER
-
-
1/2"
-
-
-
PRECISION PLUMBING PRODUCTS, INC. P2 -500
-
-
IMB -1
ICE MAKER BOX
-
KITCHEN
1/2"
-
-
-
GUY GRAY BIM875
-
GD -1
GARBAGE DISPOSER
-
KITCHEN SINK
-
-
1 -1/2"
1 -1/2"
IN- SINK- ERATOR BADGER V
-
1/2 HP, 120V, 1 PH
""�'•
0)
tj
W
Lt7
T_
oo
GENERAL NOTES
1. COLD WATER AND DRAINAGE FIXTURE UNITS AND SIZES ARE BASED ON THE 1997 UNIFORM PLUMBING CODE FOR DESIGN BASES.
2. RUNOUT PIPES FOR FLOOR DRAINS, MOP SERVICE BASINS ETC. WHEN UTILIZED IN A COMBINATION WASTE AND VENT SYSTEM SHALL BE INCREASED TWO PIPE SIZES, INCLUDING TRAP.
3. ALL EXPOSED PIPING SERVICING ADA FIXTURES SHALL BE INSULATED PER ADA REQUIREMENTS.
4. ALL FIXTURE ARE WHITE UNLESS OTHERWISE NOTED
5. SHOWERHEADS TO BE MOUNTED AT 6'6" IN WOMENS
DEFINITIONS:
SHOWER AREAS AND 7 IN MENS SHOWER AREAS.
_z
0
CT - COUNTER TOP
ADA - AMERICANS WITH DISABILITIES ACT APPROVED.
AS - ANTISCALD
BO - BOTTOM OUTLET
EB - ELONGATED BOWL
EBF - ELECTRONIC, BATTERY OPERATED FAUCET
=
W z
C) Z
EBFV - ELECTRONIC, BATTERY OPERATED FLUSH VALVE
FM - FLOOR MOUNTED
FP - FREEZE PROOF
FR - FLOW RESTRICTER
FT - TANK
FV - FLUSH VALVE
HH - HAND HELD SHOWER.
UJ
w
J
0
MV - MIXING VALVE
MF - METERING FAUCET
PB - PRESSURE BALANCING
PTB - PRESSURE - TEMPERATURE BALANCED
..J
J
PES - PORCELAIN ENAMELED STEEL
S - SOLID WHITE ELONGATED OPEN FRONT SEAT, LESS
COVER WITH CHECK HINGE
SC - SOLID WHITE ELONGATED OPEN FRONT SEAT WITH
COVER
SS - STAINLESS STEEL
VB - VACUUM BREAKER
VC - VITREOUS CHINA
VR - VANDEL RESISTANT
WFC - WALL FIXTURE CARRIER
WH - WALL HUNG
WO - WALL OUTLET
PUMP SCHEDULE
MANUFACTURER/ HEAD NPSHR PUMP VIBRATION ISOLATION
CODE MODEL N0. SERVICE LOCATION GPM FT RPM (FT) EFF. TYPE STATIC DEFL.
HWCP -1 TACO IL008 HOT WATER RECIRC MECH. RM. 6 12 3250 - - - -
GENERAL NOTES
1. FOR PUMP WEIGHTS WITH INTRRIA BASES, ADD 2 TIMES THE PUMP WEIGHT FOR THE INERTA BASE.
2. PREMIUM EFFICIENCY MOTORS.
3. FOR PARALLEL PUMP APPLICATIONS MANUFACTURER SHALL REVIEW SINGLE PUMP OPERATION SUCH THAT PUMP CAN OPERATE
AND NOT EXCEED THE END OPERATION POINT ON THE PUMP CURVE AND MOTOR HP IS PROPERLY SELECTED TO PREVENT OVERLOADING.
4. NPSHR AT SCHEDULED OPERATING POINT SHALL NOT EXCEED 0.8 TIMES NPSHA.
ELECTRICAL
HP BHP VOLT
1/25 - 120
SUCTION DIFFUSER SUCTION DISCHARGE OPER.
PH FLA YES NO SIZE SIZE WT. LBS. A
1 - NO 3/4" 3/4" 8 0
NOTES
B C D E F
3 4 0 2 4
w "
0
ci �c
a
tsy 2
' 44-
'
>
p
--
5. REFER TO DRAWINGS TO DETERMINE REQUIRED PUMP ROTATION. COORDINATE WITH MECHANICAL CONTRACTOR
6. NON - OVERLOADING AT HORSEPOWER CURVE UNLESS NOTED OTHERWISE.
PRIOR TO
ORDERING.
NOTES
7 _ 7
A. FLUID C.
0. WATER
TYPE
1. CLOSE COUPLED BASE MOUNTED CETRIFUGAL
E. DUTY F.
1. VFD, EPDM COUPLER, INVERTER DUTY MOTOR, CONTROLLER
MISCELLANEOUS
1. OPERATION AS SINGLE PUMP IN PARALLEL ARRANGEMENT
A ,
1. 30% PROPYLENE GLYCOL
2. FLEXIBLE COUPLED BASE MOUNTED CENTRIFUGAL
2. CONSTANT SPEED
2. PRIMARY /STANDBY OR SINGLE PUMP OPERATION
2. 35% PROPYLENE GLYCOL 3. IN -LINE, HORIZONTAL SHAFT CENTRIFUGAL 3. INJECTION PUMP 3. PROVIDE SPARE MOTOR
3. 50% PROPYLENE GLYCOL
4. IN -LINE, VERTICAL SHAFT CENTRIFUGAL
4. ALL BRONZE CONSTRUCTION
B. FLUID TEMPERATURE
1. 45` F D.
2. 80' F
3. 110' F
5. STEAM CONDENSATE RETURN
MOUNTING
0. NONE
1. NEOPRENE PADS
5. DDC INTERFACE MODULE
6. EMERGENCY POWER
7. FLUSHED SINGLE TUNGSTEN CARBIDE SEAL WITH FILTER ON
FLUSH LINE (CWS)
8. ALL 316SS SHAFT, IMPELLER, ALL WETTED PARTS, TEFLON PACKING
0 Rae
*
P,q
_
S
»
4. 140' F
5. 180' F
2. 4 POINT ISOLATORS
3. CONCRETE INERTIA BASE
9. FACTORY MOUNTED CONTROL PANEL, WATER LEVEL GAUGE, DIAL
THERMOMETER, DISCHARGE PRESSURE GAUGE, INLET STAINER,
STARTER ALTERNATOR
GAS LOAD SCHEDULE
PLUMBING
FIXTURE CONNECTION SCHEDULE
DRAWN BY: KAP
GAS
CODE
FIXTURE
CW CONN. HW CONN. SAN. CONN.
VENT CONN.
CHECKED BY: MPD
LOAD VALUE WC -1 WATER CLOSET 1/2" -- 3" 2,f
APPLIANCE
BOILER (8-1)
(MBH)
500
(CFH)
619
REMARKS
1
L -1 LAVATORY
KS -1 KITCHEN SINK
1/2" 1 /2$1 1 -1 /2"
1 /2" 1/2 1-1/2"
1-1/2"
1-1/2"
DATE: 6/16/6
GRILLE TOP
100
124
1
BT -1 BATHTUB
1/2" 1 /21' 1-1/2"
1-1/2"
SCALE: AS NOTED
FIREPLACE
65
80
1
SH -1 SHOWER
1/2" 1/2" 2"
1-1/2"
JOB NUMBER: VV08007.00
FIREPLACE 35 43 1 FD -1 FLOOR DRAIN - - 2" 1 -1/2"
SHEET INFORMATION:
TOTAL
700
866
GENERAL NOTES
1. COLD WATER AND DRAINAGE FIXTURE UNITS AND
SIZES ARE BASED ON THE 2003 INTERNATIONAL PLUMBING CODE FOR DESIGN
BASES.
PLUMBING
REMARKS NOTES
1. CFH BASED ON 808 BTU / 1 CFH.
2. RUNOUT PIPES FOR FLOOR DRAINS, MOP SERVICE
INCREASED TWO PIPE SIZES, INCLUDING TRAP.
3. ALL EXPOSED PIPING SERVICING ADA FIXTURES SHALL
BASINS ETC. WHEN UTILIZED IN A COMBINATION WASTE AND VENT SYSTEM SHALL BE
BE INSULATED PER ADA REQUIREMENTS.
SCHEDULES
4. ALL FIXTURE ARE WHITE
UNLESS OTHERWISE NOTED
FOR BUILDER PERMIT
SHEET NUMBER:
AND PRICING ONLY
NOT FOR CONSTRUCTION
PO,2
GENERAL NOTES•
�
f
f
f
l
11
1. CONTRACTOR SHALL INSPECT SITE TO
THOROUGHLY FAMILARIZE HIMSELF WITH THE
AREA OF WORK. ANY DISCREPANCIES
BETWEEN THESE DOCUMENTS AND ACTUAL
CONDITIONS SHALL BE REPORTED TO THE
ARCHITECT /ENGINEER FOR RESOLUTION
PRIOR TO BID PRICING. NO EXTRAS WILL BE
ALLOWED DUE TO LACK OF KNOWLEDGE OF
EXISTING CONDITIONS.
2. FIELD VERIFY EXACT LOCATION OF ALL
CONNECTION POINTS PRIOR TO
CONSTRUCTION.
3. ROUGH -IN AND FINAL CONNECT ALL
FIXTURES, EQUIPMENT, ETC.
4. FIRESTOP ANY PENETRATION THROUGH A
FIRE RATED CEILING OR WALL. VERIFY WALL
FIRE RATINGS WITH ARCHITECTURAL
DRAWINGS.
♦ . • ♦ : • •
or- s • ♦ • i ` •
KEY NOTESs
0 4" W., 1" CA 1" HW, 1 /2 " HWC UP.
ID 3" W., 1 /z" CW UP TO WC.
El 1 W., 1 /2" CW, 1 /2" HW UP TO LAY BT KS.
El 1 V. UP.
El 2" W., 1 /2" CW, 1 /2" HW UP TO SH.
® TIE NEW WASTE LINE INTO EXISTING WASTE
RISER. VERIFY LOCATION AND SIZE OF
EXISTING WASTE RISER.
El 1 /z" CW UP TO ICE MAKER.
ED 1 CW, 1 HW, 1 /2" HWC TO WN,
C9I HEAT TRACE PIPING IN UNHEATED AREA.
10 3" ST DN. TO DSN W/ SPLASH BLOCK. DSN
® 18" ABOVE FINISHED GRADE.
® NEW GAS METER !! MBH CO NNECTED
LO L METE AT EXISTING
METE MAIN BA NK B UILDING.
2" GAS R ISE R . • FLOO ♦ i
COM DO MESTIC W
PRO TECTI O N ENT
SEE DETAIL.
14 1 /z" GAS W/ ACCESSIBLE GAS SHUT --OFF
VALVE UP TO FIREPLACE.
15 Y4 GAS W/ ACCESSIBLE GAS SHUT -OFF
VALVE UP TO FIREPLACE.
16 1" GAS W/ ACCESSIBLE GAS SHUT -OFF
VALVE UP TO COOKTOP,
ISSUE 1 REVISIONS:
4 -15 -08 DD / PRELIMINARY PRICING SET
5 -5.08 95% CD REVIEW SET
5 -16 -08 PERMIT SET
101
t
t
t
uj
1
•
.0
cc
=) g
Lij
�✓i
M
o � �
QC �uu
0
" A o ^A
A
t rAA
I S 4
k
•
wr •
DRAWN BY: KAP
DATE: 05/16/08
SCALE: AS NOTED
JOB NUMBER: 08007.00
i
r: 41 , 0 1 11114 ..
4 . ..
INF THEET FLOOR
SHEET NUMBER:
F2W
ISSUE / REVISIONS:
GENERAL. NOTES1 4 -15 -08 DDI PRELIMINARY PRICING SET
5-5-08 95% CD REVIEW SET
1. CONTRACTOR SHALL INSPECT SITE TO
I THOROUGHLY FAMILARIZE HIMSELF WITH THE 5 -16-08 PERMIT SET
AREA OF WORK. ANY DISCREPANCIES
I BETWEEN THESE DOCUMENTS AND ACTUAL
! I CONDITIONS SHALL BE REPORTED TO THE
I i I ARCHITECT /ENGINEER FOR RESOLUTION
PRIOR TO BID PRICING. NO EXTRAS WILL BE
€
ALLOWED DUE T QLACK OF KNOWLEDGE OF
2. FIELD VERIFY EXACT LOCATION OF ALL
CONNECTION POINTS PRIOR TO
CONSTRUCTION.
I I 3. ROUGH -IN AND FINAL CONNECT ALL
1 I I FIXTURES, EQUIPMENT, ETC.
4. FIRESTOP ANY PENETRATION THROUGH A
FIRE RATER CEILING OR WALL. VERIFY WALL ui
I I
I FIRE RATINGS WITH ARCHITECTURAL
DRAWINGS.
5. ALL WORK SHALL BE PER LOCAL BUILDING W
AND HEALTH DEPARTMENT REQUIREMENTS. (j)
rx f
I \
t
t
l
0) Lo
I (o
11 Q '', ; KEY NOTES � man
CRI \ ',` 0 3" W., 1 /2" CW UP TO WC. Z 0
I
nT- '� , M2 1 W., 1 /2 " CW, 1 /2 " HW UP TO LAY, BT WB.
( L -1 # 3 2" W. UP TO FD. _...
( BEDROOM t 1 /y o o
F 2 " V. U P. w z fir/
3 !! ( MASTER \t e'
BATH t tY
I g V F61 3" W., 2" V., 1 /2" CW TO WC. W
12 0 ', n 1 W., 1 V., 1 /2" CW, 1 /2" HW TO LAY. BT
> KS. 0 J
CO WC `� `\
-- - Q 2" W., 1 V., 1 /2" CW, 1 /2" HW TO SH.
® 2" V. UP TO 3" VTR.
1 '
t 1
BT -2 {) 7 ', ' 10 4" W., 1" CW, 1" HW, Y/2" HWC DN. .� •
0 >
( t
1 11 3" ST UP TO AREA DRAIN. f
12 3" ST DN.
vi
® TO B OILER
4 V
T1
I .
f }
i
i
i�
i
IsOf
--UG
f/4� ! Ewa S SL Pq " o0
'4e� Y `�
3§174,
DRAWN BY: KAP
r
i tr • r �
CHECKED BY: MPD
SHEET NUMBER:
GENERAL NOTES
i
1. CONTRACTOR SHALL INSPECT SITE TO
THOROUGHLY FAMILARIZE HIMSELF WITH THE
AREA OF WORK. ANY DISCREPANCIES
BETWEEN THESE DOCUMENTS AND ACTUAL
CONDITIONS SHALL BE REPORTED TO THE
ARCHITECT /ENGINEER FOR RESOLUTION
PRIOR TO BID PRICING. NO EXTRAS WILL BE
ALLOWED DUE TO LACK OF KNOWLEDGE OF
EXISTING CONDITIONS.
2. FIEL VERIFY EXACT LOCATION O
C ONNECTION POINTS PRIOR TO
C ONSTRUCTIO N.
3. ROUGH - IN AND FINAL CONNECT ALL
FIXTURES, EQUIPMENT, ETC.
4. FIRESTOP ANY PENETRATION THROUGH A
FIRE RATED CEILING OR WALL. VERIFY WALL
FIRE RATINGS WITH ARCHITECTURAL
DRAWINGS.
5. ALL WORK SHALL BE PER LOCAL BUILDING
AND HEALTH DEPARTMENT REQUIREMENTS.
KEY NOTES
in 3" W., 2" V., 1/2" CW TO WC.
El 1 1 /2 " W., 1 V., 1 /2 " CW, 1/2" HW TO LAV.
BT, WB.
3 F 2" V. UP TO 3" VTR.
1 V. UP TO 3" VTR.
2" V. DN.
1 V. DN.
El :Y4 CW TO HI3 FOR SPA WATER FILL.
ISSUE / REVISIONS:
4 -15 -08 DD / PRELIMINARY PRICING SET
5-5-08 $5% CD REVIEW SET
5 -16 -08 PERMIT SET
t
1
•
t
uj
s
..
•
ca 0
i
" R a
w
o
ILA
ZE
T/
+ I SM
s
m
DRAWN BY: KAP
CHECKED BY: MPD
DATE: 08/16/08
SCALE: AS NOTED
JOB NUMBER: VV08007.00
SHEET INFORMATION:
THIRD FLOOR
NORTH PLUMBING PLAN
1 THIRD F LOOR PLUMBING PLAN
P1.3 SCALE: 1
llllil r
r
r
SHEET NUMBER:
�c3
ISSUE / REVISIONS:
POTTER VS -SP VANE TYPE —
WATER FLOW BALL VALVE 4 -15 -08 DD / PRELIMINARY PRICING SET
TAMPER SWITCH INTERLOCK
1 CW TO PANEL RE ALARM CONTROL 5-16,08 PERMiDTSETIEW SET
BUILDING GAUGE (TYP BYPASS ASSEMBLY WITH CIRCUIT SETTER
SYSTEM LOCKPACK VALVE (TYPICAL) FLOW SWITCH - INTERLOCK
RPBFP -1 1 W/ FIRE ALARM PANEL
PRV -1 STRAINER PROVIDE PUMP SUPPORT
cm) FINAL FIRE PROTECTION DISTRIBUTION W /GAGE COCKS PUMP MO OR NOT SUPPORT
11 12 „ 1
PIPE SIZING TO BE CALCULATED D
METER FLANGE 1112„ S TS TS -. �� PER NFPA 13 HYDRAULIC CALCULATIONS
(TYP) L_ _ BY THE DESIGN / BUILD FIRE
ZY41 11/z ” METER WITH REMOTE S PROTECTION CONTRACTOR
"
RPBFP -1: WILKINS #975 READOUT PURCHASED FROM BYPASS 1
LOCAL WATER DISTRICT PRESSURE GAUGE
INSTALLED BY P.C. IN -LINE
o ANCHOR PIPING PUMP Iii
TO WALL
RPBFP SYSTEM DRAIN
FEBCO OR WILKINS W/ BALL VALVE
DOWN TO FLOOR DRAIN Z W
ANCHOR PIPING FULL SIZE DOWN
FULL SIZE DOWN-/ TO WALL TO FLOOR DRAIN \ FLAONG OR uj Q
TO FLOOR DRAIN C _
SHUTOFF VALVE Q
0) Lo
T_
3" DUCTILE IRON WATER SERVICE
3 FIRE SPRINKLER. FINAL PIPING DESIGN
BY THE CIVIL CONTRACTOR. BACKFLOW PREVENTER, RISER & ALL FIRE UJ (D oo
REFERENCE THE SITE PLAN FOR CONTINUATION. SPRINKLER EQUIPMENT PROVIDED BY DESIGN Z O
EXACT LOCATION & INVERT ELEVATIONS BUILD FIRE PROTECTION CONTRACTOR. F.P.C.
DESIGN BUILD FIRE PROTECTION TO VERIFY PIPE SIZING PRIOR TO INSTALLATION. C In
CONTRACTOR TO VERIFY PIPE =.
SIZING PRIOR TO INSTALLATION,
1 VERTICAL IN -LINE PUMP DIAGRA 0� M p
�4�CO�MB�INA�TIO�N�DO�MES�TIC�W�ATE�R / FIRE PROTECTION ENTRY DETAIL P2.1 NO SCALE ui Z 0
P2.1 NO SCALE Z
W °J
ui 0
Q
PROVIDE HONEYWELL SPARCO 0 --�
HL -200 HIGH - LOW TEMPERATURE
CONDUIT
CONTROL MIXING VALVE PANEL
1 1 /2 "
140' F 110' F---- -- •--- -- 1 HOT WATER TO SYSTEM +�
JUNCTION GROUND -FAULT ' `I 1 1/2 COLD WATER SUPPLY
. 1 "
BOX PROTECTION DEVICE S HOT WATER CIRC.
Q__j
FROM FIXTURES
1 1
EXPANSION TANK
1 TACO MODEL PAX 30
S q
POWER INSULATION 1 /z" --'
CONNECTION -Y4 DOWN TO NEAREST
FLOOR DRAIN
PIPE '
7
DRILL. - 4" HOLE IN CHECK FLAPPER
CJ �
1 WC RECIRC. PUMP
HEAT TRACE 72 GALLON 1 CONSTRUCTION
CABLE
SUPPORT FROM FLOOR`
PIPE RELIEF VALVE ZE
TO FLOOR DRAIN
5 HEAT TRACE PIPING DIAGRAM 2 INDIRECT WATER HEATER PIPING DIAGRAM ry
P2.1 NO SCALE P2.1 NO SCALE f
0 Rep
LEAD CAULK„
3374
DOWNSPOUT NOZZLE , 1" INSULATION
WITH WALL FLANGE
P
STORM SEWER DRAWN BY: KAP
CHECKED BY: MPD
° DATE: 05116/08
PIPE SLEEVE SCALE: AS NOTED
JOB NUMBER: VVa8aa7.Qa
JUTE PACKING
SHEET INFORMATION:
PLUMBING
DETAILS
DOWNSPOUT NOZZLE DETAIL
V_VfQ NO SCALE
FOR BUILDER PERMIT SHEET NUMBER:
AND PRICING ONLY
NOT FOR CONSTRUCTION P2.1