HomeMy WebLinkAboutA10-0053 Maxsys 4020 Panel 0 IN"I'EGRATED SYSTEMS TECHNOLOGY I ' ' � ,..,,,,..,.. � 1 � 1 1 ' � �, .�LL _�_ __ _ _ The PC4020 is a 16 zone panel which is expandable to 128 zones.Expansion can ' � � � be accomplished over a 4-wire Combus using a variery of input/output and funcCional modules.The base panel includes two addressable loops which can accommodate up to 112 addressable input devices and the system can also be The PC4020 is easily expandetl by adding input/output and funetional expanded with a 64 zone wireless receiver which connects to the system via the modules onto the 4-wire communications bus (Combus). 4-wire Combus.Addressable,hardwired and wireless expansion can be used in any . Combus... up to four runs of 1,OOOfeet(305 m),can be t-tapped antl combination that suits the application. is supervised for low voltage and motlule communication. The MAXSYS is software ready to implement all the securiry, access control, • up to 16 LCD keypatls... 32 character display automation and residential fire functions by simply adding conventional or - complete system programming via keypads addressable devices,access control modules,and automation interface components. - keypatls can be`partition'or`global'operation - Ready,Armed,antl Trouble indicators—LCD4501 ' ' I ( ' , • •, - 5 programmable function keys—LCD-4501 - 27 function key options • 16 programmable zones... zones can be NC with no EOLR, NO/NC - Trouble and Armed indicators—LCD4500 with single EOLR or NC with double EOLR. - piezo buzzer for audible feedback and trouble - 30 programmable zone types&8 zone options - 4 keypad activatetl alarms—Panic, Emergency, Fire, Duress • 2 PGM outputs... each with 2 application choices: • up to 128 hardwired zones... using PC4108A/PC4116 eight and - as standard PGM output—59 programmable options sixteen zone expansion modules. - as atldressable loop—up to 112 atltlressable devices. • 1 supervised bell circuit... 59 programmable options • up to 64 wireless zones... using the PC4164RS wireless receiver and DSC wireless sensors and control devices. • 1 unswiiched auxiliary power supply • 1 switched auxiliary power supply • up to 112 adtlressable zones... using the main panel PGM outputs as addressable loops and DSC addressable sensors. • supervised digital alarm communicator with 4 formats: - 20bps, 1400/2300Hz handshake Hardwired,Wireless antl Addressable zones may be mixed on the system - Contact ID - SIA with auto-reporting codes up to the total system capacity of 128 zones. • 3 telephone numbers... 32 digits each • up to 144 low current outputs... using PC4216 modules—16 outputs • 3 event initiated pager formats per motlule —9 modules per system. • supervised battery charger • up to 64 relay outputs... using PC4204 quad relay/power supply • PC-Link connector...for local upload/download modules—up to 16 modules/system—each PC4204 also provides up • 8 system partitions... 9 account codes to 1 amp of auxiliary power and can be used to repower the Combus. • 1,000 user/card codes... 64 access levels • point/graphic annunciation... using PC4632/PC4664 remote • user/card codes assignable by partition annunciators for system, partition and zone annunciation • 3,000 event buffer... 2,800 viewable on keypatl • up to 32 access controlled doors... using up to 16 PC4820 • 59 programmable output options for: two reatler access control modules with stand alone capability. -bell zone, PGM outputs, relay outputs,transistor outputs • X-10 automation... using the Escort PC4580 module—controls up to • comprehensive scheduling: thirty two X-10 tlevices and provides voice assisted system status and - 99 date schetlules - 50 arm/disarm schetlules control from any touchtone telephone. - 16 automation schedules - 4 two year holitlay schetlules • system printer or DIIACS communicator... using the PC4400 - 99 open/close suppression schedules printer/DVACS interface motlule. - 50 addressable smoke detector test schedules • backup alarm communication using : • multiple communication capabilities: - Links1000'"cellular communicator - built in tligital dialer - Links2150'"or Links2450'"long-range radio transmitters. - optional module for DVAC - optional cellular communications - optional Long-range radio communication All of the features, functions, and expansion capabilities of the PC4020 • upload/download capability...full featured with separate control panel are included in the PC4020CF versions. upload/tlownload phone number . 1 ' � 1 • 1 ' " • bell output... 12VDC,�OOI11A I118X.COI1tIIlUOUS ADORESSABLE OETECTORS - up to 2A for 4 minutes using battery assist. F`° ° � �- - PTC over current protectetl—self-restoring. rWo add�essabie iooPs Pe�System, home-run,T-tapped,or star • AUX+output... 12VDC,5OO I11A I11aX. connected using 2 conductor unshielded station wire � ,,,,. , ., • SAUX+output... 12 VDC,300 mA max. " - SAUX+output is normally+12VDC and power is removed upon activation.Typically used to reset 4-wire smoke detectors. ' '' ' OTHER ' �' OTHER Note...total for AUX+output antl SAUX+output is 500mA max. � �� Moou�ES �� Moou�Es e.g. If the SAUX+output is loaded to 200 mA then only 300 mA remains for the AUX+output. COMBUS • AUX+and SAUX+outputs protected by a common PTC over current device which is self-restorin A�y ieg�P to A PC4204 is addetl when atlditional 9• COMBUS power is required to power 1,000'(305m) modules downstream from PC4204 • PGM outputs: r�om Pcaozo with —up to 16 PC4204's per system— - as standard PGM outputs... 12VDC, 50mA max.each. 4�o�d��to� PGM outputs are normally unpowered and switch to+12VDC °°Sh'eided station wire upon activation. - as adtlressable outputs... 12VDC, 170mA max.each DOOR 1 uooR 2 Note... PGM outputs are intlividually programmable as addressable � � 0 0 0 loops or as general purpose PGM outputs. � � '' � WIRELESS OETECTORS � � �� i &CONTROLS • Combus... 500mA max.from the PC4020 main panel � , - atltlitional power is provitled by PC4204 modules. Maximum Combus capacitance is 80nF which is typically 4,OOOfeet(1,219m) of 22AWG wire. Consult wire manufacturer for specifications of � � • � � , � wire to be used. � Note...total loading for the Bell output,AUX+, SAUX+, PGM1, PGM2 PC4020... security control panel which includes: and the Combus must not exceed 900mA.This limit may be exceeded - PC4020... main control motlule by bell output if extra current required is drawn from the battery. - pC4050C... beige cabinet • battery charger... up to 350mA to charge 12volt lead-acid batteries - installation manual, user manual,and programming worksheets up to 14Ah capacity. Battery charger is supervised for opens and is - module mounting hardware and 32 EOL resistors protected by PTC over current device which is self-restoring. PC4020CAR...as PC4020 but with PC4050CAR attack resistant cabinet • input power... 16VAC,40VA Keypads are not supplied with the main panel—at least one keypad is requiretl per system.Select from the following keypatl types: • ground fault tletection... built-in and enabletl by connecting earth LCD4500...alphanumeric keypad without function keys ground to EGND terminal on PC4020 main panel. (use for'CF'version panels only) LCD4500T... as LCD4500 but with wall tamper switch LCD4501...alphanumeric keypad with 5 function keys LCD4501T... as LCD4501 but with wall tamper switch � , � • � 1 LCD4520/20T, LCD4500R/TR, LCD4521/21T, LCD4501R/TR... itlentical to the above but have retl bezels for use with PC4020CF fire panels. • operating environment - 32 to 122°F(0 to 50°C) - 90% RH non-condensing , • PC4050C beige cabinet: � - surface mount usa������ CANADA - hinged d00r Wlth SCI'ew CIOSUI"2. UL1610.... Central Station Burglar Alarm ULC-5527....Central Station Fire Alarm - prOVision for door keyloCk UL609...... Local BurglarAlarm ULC-5302....Central&Monitoring Station rovision for door and wall tam Bf SwItChOS. UL365...... Police Station Burglar Alarm Burglar Alarm p p UL985...... Householtl Fire Warning ULGS303.._Local Alarm(Commercial - space for two 12volt 7Ah leatl-acid rechargeable batteries. u�io2s.... Housenoid eurqiar Aiarm Burglary) - 14.8"H X 12.0"W X 4.9"D (37.6 X 30.5 X 12.5 Cm) ��� pt least one fire version keypad must ULGS310....Household Burglar Alarm be used with Maxsys UL listed'CF' ULC-S545....Household Fire Warning commercial fire panels UL294..........Access Control ��� The Links10U0T"'Cellular Communicator . has not been investigated 6y UL 7�l�/1� 002002 Digital Securiry Controls Lcd. ��� Toronro,Canada www.dsc.com E Q M IS09001 ren�is[eied company z° DSC is a regiscered crademark of Digical Secu�iry Concrols Lcd.and may noc be reproduced widiouc permission. P�inced in Canada 2002.07