HomeMy WebLinkAboutDC Power Supply POW�ER SUPPLI�S DC POWER SUPPLY MODEL DCP-1 .5-W rT TECHNOLOGIES DESCRIPTION � � � ,� The Model DCP-1.5-W is a regulated 1.5 amp power supply '�,; that accepts 24 VAC at the input and provides 24 VDC at the g. . �:�, �; �`a output. The Model DCP-1.5-W can be ordered with any output ' �`�� � ���.;,��� _ v o l t a g e f r o m 1.5 V t o 2 7 V D C. F i e l d v o l t a g e a d j u s t m e n t s m a y ' �, ��,� �'�`�`�� '�� ,� also be made using only a screwdriver.The power supply is pro- ,, , �� ' '�� ` vided with a mounting track for easy field application. � 1` " - � ''� These low cost power supplies feature good regulation and r �! ' have full overcurrent protection. 4� '�"���� �' `—..°.�1 Y ❑ y ,i^ �7 , J - FEATURES ' � k `• ` ` • Low cost • Regulated DC output • Snap-track mounted DIMENSIONS/WIRING • Screw terminals with pressure plates in _ 4.0 APPLICATION NOTES (cm) I c�o.,6� �I SNAP-TRACK ••• •As a rule of thumb, the output current rating will be reduced MOUNTING �� by the ratio of the output voltage divided by the input volt- c�����ded> �D3 age. For example, a 6 VDC supply powered by a 24 VAC trans- O II�O — former will have a reduced rated out put current of 375 mA. � a � (5.56) (6/24)x 1.5=0.375 VOLTAGE o��T � � � � To obtain the full rated output current at reduced output voltages� ADJUSTMENT q� �, � � � G GF3 �—� the standard power supply input voltage must be reduced. It is a DCP-1.5-W �o�o�T �A��N FUSE good practice to maintain the same AC input voltage as the desired DC output voltage. REGULATED + LINE •A grounded DC minus terminal and a grounded secondary D OUOTPUTGE - z4INA� - �TRANSFORMER' 24 VAC input transformer will blow the unit's fuse. If this is a problem, there are 3 possible solutions: 'INPUT TRANSFORMER VA RATING AT 24 VAC= 43.2 x DESIRED DC OUTPUT CURRENT Option 1: Remove the ground on the transformer secondary FOR FULL 1.5 AMP CAPACITY,USE A 75 VA to float the voltage output or use a separate TRANSFORMER. ungrounded transformer. Option 2: Add a Y65GS-1 40 VA Isolation Transformer. (This reduces power supply capacity to 920 mA.) SPECIFICATIONS Option 3: Remove diode D3(marked on board).Jumper the VDC � � (-)terminal to the outside AC(G)terminal.The Input voltage 24 VAC, 50/60 Hz grounded side of the AC supply should be wired to �Output voltage 24 VDC adjustable the AC(G)terminal. (This reduces the power supply 1.5V to 27 VDC capacity to 400 mA.) Output current 1.5 amps Regulation 1.5% at full rated current Temperature stability 1% Overcurrent protection 3 amp fuse(GF-3) Dimensions 4.0"L x 2.19"W x 2.125"H (10.16cmx5.56cmx5.39cm) �Operating conditions 32°to 130°F(0 to 55°C) Weight 0.4 Ib(0.18 kg) ORDERING INFORMATION DCP-1.5-W Power Supply, 24 VAC IN to 24 VDC OUT DCP-1.5-W-C Power Supply, 24 VAC IN to Special DC output* *Specify output voltage when ordering (1.5 to 27 VDC) KELE&ASSOCIATES•P O Box 34817•Memphis,TN 38184 901-937-4900•FAX 901-372-2531 •E-mail info@kele.com