HomeMy WebLinkAbout6 Amp Power Supply jci-60477:a APS2-6R � �,� 6.0 Am Auxiliar Power Su I Oh115011 �� ` p Y PP Y � .l COIltf0�5 General "" � The APS2-6R is a state-of-the-art, 150 watt, switching auxil- �� � �^ .-o e��.o_� � �; A � iary power supply providing 24 VDC of filtered DC power. The � :,� ,o_a,. , � a � °���' APS2-6R provides three 24 VDC output circuits, rated for 6A ,;,� -�" �'� Amps in alarm and 4.0 Amps continuous. It is used for the � � � - � �',a,'*_ -� operation of peripheral audible/visual devices (a�arm signaling �°_:,R�'�� —_- 1..,� � appliances)for the IFC control panels. �, NOTE: The APS2-6R can also be used with Legacy panels. � Please refer to the APS2-6R manual for more information. � Features R I ' • UL 864 Ninth Edition compliant • Lightweight,compact design • 120 or 220/240 VAC(@ 50/60 Hz)versions � • Output circuits with overload protection _ -� - • Built-in"brown-ouY'circuitry • Diagnostic trouble LED • Plug-in connector for in-cabinet applications and screw ter- Fuse: (F2 battery supervision): 32 VAC, 10.0 A, Fast-Acting minals for remote device applications Automotive Minifuse. • Trouble supervision bus Trouble supervision bus: J3 output: Form-A contact (open • Shares battery and charger circuit with control panel collector).J4 input: Form-A contact(open collector). • Power-limited design, per UL requirements NOTE: J3 and J4 can be interchanged. • AC Fail supervision and reporting with field-selectable delay Loss of AC indication: Immediate indication (default); 1-2 per UL 864 hour delay(cut JP2);2-3 hour delay(cut JP2 and JP3). • Heavy-duty clamp-type terminals accept up to 12 AWG (3.1 mm2)wire MECHANICAL SPECIFICATIONS • Battery voltage supervision The APS2-6R measures approximately 8.625" (21.91 cm) x • Low battery disconnect 6.625" (16.83 cm) x 2.375" (6.03 cm) and weighs approxi- • Mounts in a standard CAB-3/CAB-4 Series cabinet. mately 2 Ibs(0.91 kg). Construction and Operation Cabinet for Mounting When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, - CAB-3/CAB-4 Series: Use CHS-4 and CHS-4L chassis, for B3/-B4, -C3/-C4, or -D3/-D4), the APS2-6R mounts to a IFC2-3030, IFC2-640, IFC-3030, IFC-640, IFC 1010/2020, CHS-4 or CHS-4L mounting chassis. If more than one APS2- and IFC-400 control panels. 6R is necessary to satisfy Audible/Visual (DC) power require- PrOdIICt LI11@ IItfOP111at1011 ments, connect additional APS2-6R power supplies together as described in the Installation Instruction Manual #53232. APS2-6R:24-volt,filtered power supply(120 VAC input). Underwriters Laboratories requires that all Signaling Appli- ApS2-6RE:24-volt,filtered power supply(220-240 VAC input) ances be approved for use with the selected control system EOLR-1: 12/24 VDC end-of-line relay. due to voltage operating range criteria. Use only those appli- ances listed for use with the associated control system. Refer CHS-4: Four-module chassis. to Device Compatibility Document#51922. CHS-4L: Four-module chassis(low-profile). Specifications R-47K: End of Line Resistor Assembly ELECTRICAL SPECIFICATIONS Installation Standards and Codes AC primary input power (TBi): APS2-6R: 120 VAC, 50/60 This power supply complies with the standards set forth by the Hz, 2.9 A.,APS2-6RE :220-240 VAC,50/60 Hz, 1.5 A. following regulatory agencies: DC secondary input power(TB3):TB3-1 (+),T63-2(-). NFPA Standards 24 VDC output power (T62): Total 6.0 A (4.0 A continuous). . NFPA 72 National Fire Alarm Code Circuit 1 (TB2-1,T62-2):3.0 A@ 24 VDC power-limited.Cir- cuit 2(T62-3,T62-4): 3.0 A@ 24 VDC power-limited. Underwriters Laboratories: 24 VDC output power (J9): 6.0 A (4.0 A continuous), Non- ' UL 864 Standard for Control Units and Accessories for Fire Power Limted. Alarm Systems Relay Contacts(TB4):AC Fail supervision over the SLC. In addition, the installer should be familiar with the following standards: jci-60477:a•6/2/2009—Page 1 of 2 • NEC Article 300 Wiring Methods • Applicable Local and State Building Codes • Requirements of the Local Authority Having Jurisdiction • The Canadian Electrical Code, Part 1 Agency Listings and Approvals The listings and approvals below apply to the basic APS2-6R. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL S635 �02009.All rights reserved.Unauthorized use of this document is strictly pro- hibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S.A. For more information,contact Johnson Controls Field Support Center. 507 East Michigan Street,Milwaukee,WI 53202 www.johnsoncontrols.com Page 2 of 2—jci-60477:a•6/2/2009