HomeMy WebLinkAboutLamp Driver Module JCI-60011:A LD"" J HNSON Lamp Driver Modules CONTf� L� General � � � � � =' J5 J6 OUTPUTS J7 J8 The LDM Series lamp driver modules,when combined with a � � ���ID', �S�o� � custom graphic display, provide annunciation and control for ^ � � � J10� the IFG3030, IFC2-3030, IFC-640, IFC2020/1010, IFC400, 0 P wER�s : IFC-200,and FC-2000 control panels. These modules use a � serial communications interface,and may be located up to : sw�TCH 6,000 feet from the panel. : MATR�X Features J' � �sW, ALARM/CIRCUIT ON and TROUBLE lamp/LED per-point �swz � � J2 • option,or more dense alarm-only option (field selectable). • Control switch option for remote control per point. 's"'3 � � • Lamps/LEDs may be programmed to display status of indi- �sw4 cating circuits or control relays as weil as system status � 3 conditions. � � �B� � � °� m , • System trouble lamp/LED signal. m � m 6 • On-line/power LED indicator. � ; Te, � � • Optional RPT-485 increases EIA-485 wire distance. m 2 ` 0 � ON LINE� • Optional fiber-optics EIA-485 transmission with RPT-485F �E� wire-to-fiber converter. � � � • Alarm and trouble resound with flash of new conditions. � • Local sounder for both alarm/circuit-on and trouble condi- LDM-32 tions with silence/acknowledge switch connection. • Serial EIA-485 interface for reduced installation costs. • May be powered by 24 VDC from the panel or by remote Installation power supplies. The LDM-32 and LDM-E32 modules mount on four standoffs • Efficient switch-power converter reduces power consump- inside the custom annunciator graphic box. Alternately,the tion. modules may be installed in a CHS-4L chassis. The module • Microprocessor-controlled electronics,fully supervised. size is approximately 4.4"(11.2cm)x 7.1"(18cm). • Plug-in terminal blocks for ease of installation and service. Communications between the LDM Series annunciators and • Trouble monitor option for remote power supplies. the host Flre Alarm Control Panel are made through a two-wire EIA-485 multi-drop loop,and a two-wire regulated 24 Construction VDC power loop. Up to 32 LDM systems may be connected to a single control panel. Two basic models are available;the LDM-32 control module All field-wiring terminations use removable, compression-type and the LDM-E32 expander module. Each may be selected to terminal blocks for ease of installation,wiring,and circuit test- provide 32 alarm indications;or 16 alarm, 16 trouble, and 16 ing. control points. Applications Operation LDM Series modules,when used with a custom graphic The LDM-32/LDM-E32 with a custom graphic array may be annunciator, provide the JCI IFC-3030, IFC2-3030, IFC-640, used to indicate point status and, in some versions,to control IFC-320, IFC2020/1010, IFC400,IFC-200,or FC-2000 with up the state of output points. to 32 unique or redundant annunciators,each with a capacity In addition,the LDM-R32 module may be used to provide 32 of 64 points for a total capacity of 2048 points. dry-contact relays for electrical isolation when connecting the Local or remote power supplies and serial communications system to other equipment. allow the custom annunciators to be located anywhere on the protected premises. IFC-2020/1010 system alarm and/or trouble conditions may be annunciated on a per-point basis,or in a grouped-zone config- uration. IFC-400 system panel points, intelligent addressable devices and software zones can be annunciated/controlled in a grouped fashion(see programming manual for details). Control of system operational controls,such as Signal Silence, System Reset,and local annunciation controls(such as Local JCI-60011:A•11/1/06—Page 1 of 2 Acknowledge),and Lamp Test may be accomplished through with a dip switch selection. Flash of new alarms or troubles is special key-or push-switches. selectable through dip switches. 16 switch inputs may be used for panel SILENCE, RESET,or remote relay control. Instruc- Agency Listings and Approvals tions are included. These listings and approvals apply to the modules specified in LDM-E32: Lamp Driver Module with 32 alarm drivers;or 16 this document. In some cases,certain modules or applications alarm, 16 trouble,and 16 switch inputs. One LDM-E32 is may not be listed by certain approval agencies,or listing may allowed per LDM-32 in alarm-only mode. Three LDM-E32 be in process. Consult factory for latest listing status. modules are allowed per LDM-32 in alarm/trouble. Includes ribbon cable to connect to ACM. • UL Listed: S635 LDM-R32: Lamp Driver Module which connects to any LDM- • ULC Listed: CS100 32 or LDM-E32 to convert transistor outputs to 32 Form-A dry • MEA Listed:317-01-E3(IFC-640);345-02-E Vol. II (IFC- contacts(1.0 A@ 30 VDC). Provides 32 output terminal 3030) screw connections and a single common terminal screw. • CSFM: 7165-0554:149(IFC-3030, IFC2-3030);7170- Includes ribbon cables to connected to the LDM-32/LDM-E32. 0554:150(IFC-3030, IFC2-3030);7170-0554:142 (IFC- Use for electrical isolation when interfacing the system to other 640);7120-0554:129(ACS Annunciators) equipment. • FM Approved (IFC-640) LDM-CBL24,LDM-CBL48: Ribbon cable sets to provide • City of Chicago approved:Class 1, Class 2 either a 24"(60.96cm)or 48"(121.96cm)connection between • City of Denver approved LDM-32/LDM-E32 and LEDs or lamps on a custom graphic panel. Includes all cables necessary for one LDM-32 or LDM-E32. Cables have connector on one end only(split,strip, Product Line Information and connect other end to graphic annunciator). LDM-32: Lamp Driver Module with 32 alarm lamp-driver tran- sistors(sink to power common on alarm). May be selected Architectural/Engineering (dip switch)for 16 alarm/circuit on, 16 trouble,and 16 switch Specifications inputs if desired. Also includes system-trouble lamp driver and lamp-test/local-acknowledge switch input. Integral piezo For specifications on LDM Graphic Annunciator Lamp Driver sounder sounds for each new alarm or trouble and is silenced Modules,contact JCI. with the Local Acknowledge switch,or permanently disabled ���� J4�6 OUTPUTS J7� JS JS�J��J7�Jq� J10° J10� O ■K1 K32■ 0 � � � OO _ ■K2 K31■ � � O � TB� ■K3 KJO■ TB4 �SWITCH �z■ ■e C'v� MATRIX �� K4 K29 6� �4 �5B ��■K5 K28■ � .11 � �6 3 m � - �B■K6 K2]■�� � �Z ■K� K26■ TB5 ■ ■ TB6 �� KB K25 Q� � �2 3 f� �a■K9 K24.2 Q �SW4 ■K10 K23■ t T82 K11 K22 TB3 Bf+I O �a■K12 K21■a�, �5■K13 K20■ � �6 3� - �8■K14 K79■�� 3 5 � 5 ■K15 K78■ C � ?5 $ C ■K16 Kt]■ o � � I LJ�L� LJ I.�. ° O � � � � LDM-CLS24, �� / LDM-E32 LDC-CBL48 LDM-R32 �02006 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S.A. For more information,contact Johnson Controls Field Support Center. 507 East Michigan Street,Milwaukee,WI 53202 www.johnsoncontrols.com Page 2 of 2—JCI-60011:A•11/1/06