HomeMy WebLinkAboutUntitled (243) IPM.Note FW: B09-010 Solaris Spa FW: Dave Leiker SMTP dleiker@bcer.com Dave Leiker SMTP dleiker@bcer.com Mike McGee; maggie.fitzgerald Steve Rondinelli B09-010 Solaris Spa Steve Rondinelli: Please address these comments with Maggie Fitzgerald and get back to me. FYI, the Flex Head brand device has recently receive UL listing approval via a new UL standard. Please research the Flex Head site for the press release on this approval. When you have a re-submittal plan, let me know so I can review it with you. Thanks. Dave Leiker -----Original Message----- From: Mike McGee [mailto:MMcGee@vailgov.com] Sent: Monday, February 09, 2009 2:40 PM To: maggie.Fitzgerald@davispartnership.com Cc: Dave Leiker; Chris Gunion; David Rhoades; JR Mondragon; JR Rulapaugh; Mike McGee; Mark Miller; Mike Vaughan Subject: B09-010 Solaris Spa Resubmittal required. 1. Plans indicate 2 burner residential stove top. No ducting provided. Question intent and use of residential stove top. M0.02 2. FCU and return appear insufficient if stove top is intended for melting wax. Based on similar code required installations, provide minimum six air changes. M0.02 3. Smoke detectors are not suitable in rooms with non-ducted stove top, laundry rooms, and rooms with high moisture. FAFP0001 Rm 229 and 230 4. Detail for fire sprinkler head indicates "flex head" but comments indicate cast iron fittings. Flex heads are not approved without additional justification and installation details. FAFP0000 Mike McGee SMTP MMcGee@vailgov.com MMcGee@vailgov.com Mike McGee Steve Rondinelli SMTP Srondinelli@bcer.com Srondinelli@bcer.com Steve Rondinelli maggie.fitzgerald SMTP maggie.fitzgerald@davispartnership.com maggie.fitzgerald@davispartnership.com maggie.fitzgerald