Re: Solaris Emergency Escape and Rescue Openings
Re:
Martin Haeberle
SMTP
MHaeberle@vailgov.com
Martin Haeberle
SMTP
MHaeberle@vailgov.com
Chris Gunion
Mike McGee; Brian_Thompson@schirmereng.com
Solaris Emergency Escape and Rescue Openings
Brian,
In adding to Mikes opinion, exception 5 is applicable. Emergency egress windows will not be required in high rise applications.
Martin A. Haeberle, C.B.O.
Chief Building Official
Town of Vail
75 South Frontage Road
Vail, Colorado 81657
970.479.2142 (o)
970.479.2452 (f)
970.376.3672 (c)
>>> Mike McGee 09/11/2008 8:24 AM >>>
History aside, I am of the opinion rescue windows are not applicable in this project (Exception 5).
The deletion of exception 1 has some background with respect to fire access. Cross ventilation in sprinklered buildings is very much a tactical option.
Exception 4 is related to what we saw as a trend to install mechanical equip in "crawl spaces" (ie confined space as defined by OSHA and with some suspicion the space could be altered
after the CO).
>>> <Brian_Thompson@schirmereng.com> 09/10/2008 6:42 PM >>>
Martin,
Per our telephone conversation today, I am sending this request for
clarification on the code requirement as enforced by Vail for emergency
escape and rescue openings.
2003 IBC, Section 1025, requires these openings for Group R occupancies.
However, exception 1 does not require them for buildings that are
sprinklered and exception 5 does not require them for buildings that are
considered high-rise buildings.
TOV has amended this section by deleting in their entirety, exception 1
and 4.
Since exception 5 has not been deleted by TOV amendments, are we allowed
to not provide emergency escape and rescue openings for Solaris?
Regards,
Brian Thompson, P.E.
Denver Regional Manager
SCHIRMER ENGINEERING
3033 South Parker Road
Suite 460
Aurora, CO 80014
Tel: 303.283.0236
Fax: 303.283.0241
Email: brian_thompson@schirmereng.com
Web Address: www.schirmereng.com
NOTICE: This message may contain information that is privileged and/or
confidential and is intended for the sole use of the intended recipient.
If you are not the intended recipient or a person responsible for
delivering it thereto, you may not disclose, use, disseminate, distribute,
copy or take any action in reliance upon this message or any attachments
thereto in any way. If you receive this message in error, please return it
by forwarding the message and any attachments to the sender.
Schirmer Engineering Corporation is not responsible for any errors,
omissions, corruption or virus in the contents of this message or any
attachments thereto.
Chris Gunion
SMTP
CGunion@vailgov.com
CGunion@vailgov.com
Chris Gunion
Mike McGee
SMTP
MMcGee@vailgov.com
MMcGee@vailgov.com
Mike McGee
Brian_Thompson@schirmereng.com
SMTP
Brian_Thompson@schirmereng.com
Brian_Thompson@schirmereng.com
Brian_Thompson@schirmereng.com