Loading...
HomeMy WebLinkAboutD10-0002D10-0002: Entries for Item:90 - BLDG-Final 08:43 01/17/2013 Action Comments By Date Unique_ Ke AP jrm 01/18/2012 A000148 620 Total Rows: 1 Page 1 TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 Job Address: Location.......: Parcel No....: DEPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES DEMO. OF PART/ALL BLDG. 115 FOREST RD VAIL 115 FOREST ROAD 210107113030 OWNER 115 COMPANY 4960 S LAFAYETTE LN ENGLEWOOD CO 80113 APPLICANT BECK BUILDING COMPANY P.O. BOX 4030 VAIL CO 81658 License: 117-A CONTRACTOR BECK BUILDING COMPANY P.O. BOX 4030 VAIL CO 81658 License: 117-A Desciption: DEMO HOUSE 0�/23/2oio Permit # D10-0002 Project # ?? Status . . . . Applied .. . : Issued . . . : Expires.....: ISSUED 07/23/2010 08/24/2010 02/20/2011 07/23/2010 Phone: 970-949-1800 07/23/2010 Phone: 970-949-1800 Occupancy: R3 Single Family Residence Type Construction: VB Valuation: $48,000.00 Revision Valuation: ?? Total Sq Ft Added: 0 *s*�»s*s**+s***ssa*sr*s►s*+�ssss+s�s+s+�++�+s+ss*�**st*+***********s FEE SUMMARY :�+►+s+�s+ss**s****+**a****s*+s+**a*s++srs+ss�+sa3++s3+s+s+s Building----> $623 . 55 Restuarant Plan Review—> $o . oo Total Calculated Fees—> $1, 032. 86 Plan Check---> $ 4 0 5. 31 Recreation Fee------------> $ 0. 0 0 Additional Fees----> $ 0. 0 0 Investigation-> $ 0. 0 0 TOTAL FEES-----------> $1, 0 3 2. 86 Total Permit Fee-----> $1, 03 2. 86 W il I Call-----> $ 4. 0 0 Payments------------------> $1, 0 3 2. 8 6 BALANCE DUE----> $ o. o 0 ##i*###*#s##**##R##4###tt###t##+######R###�###+#►+#4#i4#+#####4#*##�Ft*+##*#########t####t####4#t###►+##+#+#i+ft#R4##t###*rt#s#sstsst#s*#a*#sR*ssss Approvals: Item: 05100 BUILDING DEPARTMENT 08/04/2010 jrm Action: AP Item: 05400 PLANNING DEPARTMENT 07/29/2010 bgibson Action: AP see conditions. plans routed to JR Mondragon. Item: 05600 FIRE DEPARTMENT 08/05/2010 drhoades Action: DN Asbestos permit/abatement/final air clearance needed prior to demo permit approval. Contractor was notified (Matt, 376-4447) and is aware of this fact. #######k##*####i##*###��#t##►#tt###*#####*###############*k�###t4f+f4#4t#4#i##*#*###############t#fk#f##it#t#i###################ff#4#f#*##4ii►ti See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM • 4 PM. i9►� � �`� SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ******************************************************************************************************** CONDITIONS OF APPROVAL Permit #: D10-0002 as of 08-24-2010 Status: ISSUED ******************************************************************************************************** Permit Type: Applicant: 08/24/2010 Job Address: Location: Parcel No: DEMO. OF PART/ALL BLDG. BECK BUILDING COMPANY 970-949-1800 115 FOREST RD VAIL 115 FOREST ROAD 210107113030 Description: DEMO HOUSE Applied: 07/23/2010 Issued: To Expire: 02/20/2011 ***********************************************Conditions:************************************************ Cond: 38 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479-2252. Cond: 1 (FIRE): FIlZE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIlZED TO CHECK FOR CODE COMPLIANCE. Cond: CON0011543 The applicant shall re-grade and re-vegetate the site to a natural state within 14 days of completing demolition if a building permit for the proposed new residence has not been obtained and construction is being diligently pursued. ***r****+****�****s******�*************��**�***********************************************s TOWN OF VAIL, COLORADO Statement *«***********+****«**��**********************�**��*********�******************+**********�** Statement Number: R100001144 Amount: $1,032.86 08/24/201011:47 AM Payment Method: Check Init: JRM Notation: ----------------------------------------------------------------------------- Permit No: D10-0002 Type: DEMO. OF PART/ALL BLDG. Parcel No: 2101-071-1303-0 Site Address: 115 FOREST RD VAIL Location: 115 FOREST ROAD Total Fees: $1,032.86 This Payment: $1,032.86 Total ALL Pmts: $1,032.86 Balance: $0.00 *ts******r*************�*********�******************+*********+***************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 623.55 PF 00100003112300 PLAN CHECK FEES 405.31 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- Separate �TNG PERMIT APPLICATION e���-t`o�. � required for electrical, piumbing, mechanicai, fireplace, etc. Project Street Address: I f � ��-es�� (Number) (Street) (Suite #) Building/Complex Name: Contractor Information: Company: e c.� � i��� tia ��J i,,.��n� Company Address: ��tic ��� � Detailed Scope and Location of Work: �� {� " G,O�s City: �s`i � State: � Zip: �,� ,� � �,�r� Contact Name: V�� � D�Z�T�t Contact Phone: l� – °(�{ G '� (C6'pD (1 ��� � r� (use additional sheet if necessary) E-Mail �elsi.� oJ s c,� � S• �r� l��_ � Work Class: , : Town of Vail Contractor Registration No.: � New Addition p� ( ) ( ) Remodel ( ) Repair ( ) Other _ , `\. X Work Type Contractor Signature (required) Interior O Exterior O Both (� Property Infortnation TYPe of Building: , Parcel #: � �� �'� C�7 i — � �-- C53� Single-Family� Duplex ( ) Multi-Family ( ) (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or Commercial Other visit www.eaglecounty.us/patie) � ) � ) Tenant Name: ; Does a Fire Alarm Exist? Yes O No �j Owner Name: %�� �t�..� a.. y Monitored Alarm? Yes O No (� � Does a Sprinkler System Exist? Yes O No (� IOffice Use: � n ��� � � ` �,� Project #: , ��L DRB #: Building P i Lot #: Block Subdivisi . _ ns (Labor & Materials) c^' _ -_ j ,'; �/' � ,� I `�� i� r -, 1����� (including firepl�ce) ti,i� �� .,_..._ � Total: vr • # 8� Type of Existing Fireplaces: Gas Appliances Gas Log Wood/Pellet Wood Buming �_ #& Type of Proposed Fireplaces: Gas Appliances Gas Log Wood/Pellet Wood Burning _ �-%� !�!.'7� �� .. . . � �' � J?.114 � � � ��� �� , Fl O1-Jan-10 Asbestos Inspection and Sampling Report 115 Forest Rd, Vail, Colorado 81657 Presented to: Mr. Kevin 0'Donnell Beck Building Company PO Box 4030 Vail, CO 81658 Performed & Prepared by: Mr. Steve Shurtliff DS Consulting, Inc. P.O. Box 6864 Avon, CO 81620 (303) 378-1544 Project Details: DSC Project #: 2435 Conducted: June 29, 2010 � C�nsultin g � � � O EXECUTIVE SUMMARY On June 29, 2010, Mr. Steve Shurtliff of DS Consulting, Inc. (DSC) performed a full building inspection and collected asbestos bulk-samples at 115 Forest Rd, Vail, Colorado, in order to identify potentially hazardous friable and non-friable asbestos-containing materials (ACM) within the above-referenced, single-family residence scheduled for full demolition. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (ACM) as a material containing more than 1% asbestos. Mr. Shurtliff performed asbestos bulk-sampling of multiple varieties of drywall (surfacing materials) in a total of eleven (11) locations within the upper and lower level, plaster (surfacing material) in a total of three (3) locations on the exterior of the residence and resilient floor tile (miscellaneous material) in a total of one (1) location within the lower level (see AppendixA for sample locations). All fifteen (15) bulk-samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP #200860-0) in Denver, Colorado with eight (8) laboratory results initially reporting positive for asbestos between 1.5% and 4% Chrysotile (see Appendix C for laboratory results). The bulk-sample with the highest percentage of asbestos within each homogeneous group was then re-analyzed using the point- count method to determine the exact percentage of asbestos within the sample in order to verify it's percentage of asbestos was greater than 1%. All three (3) bulk-samples re-analyzed by the point-count method were reported as containing greater than 1% Chrysotile asbestos. The following sampled materials were found to contain asbestosgreater than 1%(ACM): � � � � � � � � Drywall Upper Level Surfacing >1,OOOftz o DW01-03 Type 1 Bedroom 1 Material Friable �S,OOOft2 Good 2/o Chrysotile Drywall Upper Level Surfacing >1 OOOftz 2% - 3% DW01-04 Type 1 Kitchen Material Friable �S,OOOftz Good Chrysotile Drywall Upper Level Surfacing >1,OOOftz 2% - 2.5% DW01-05 Type 1 Bathroom 4 Material Friable �5,OOOft2 Good Chrysotile PC Drywall Lower Level Surfacing 1.5% -1.75% DW02-03 Type 2 Bedroom 5 Material Friable <1,OOOft2 Good Chrysotile PC DW03-01 Drywall Lower Level Surfacing Friable <1,OOOftz Good 3% - 4% Type 3 Game Room Material Chrysotile Drywall Lower Level Surfacing 3.25% - 2.25% DW03-02 Type 3 Game Room Material Friable <1,OOOftz Good Chrysotile PC DW03-03 Drywall Lower Level Surfacing Friable <1,OOOftz Good 3% Chrysotile Type 3 Game Room Material FT01-01 Resilient Lower Level Miscellaneous Non- �1,OOOftz Good 2% Chrysotile Floor Tile Family Room Material Friable "Quantities are approximations and subject to field verification. PC=point-count 2 PROjECT OVERVIEW I. Introduction A full building inspection and bulk-sampling for ACM was conducted at 115 Forest Rd, Vail, Colorado, by Mr. Shurtliff on June 29, 2010, at the request of Mr. Kevin 0'Donnell with Beck Building Company. Mr. Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix B for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non-friable ACM within the residence. II. Structural Design The structure is a wood-framed, two-level, single-family residence. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a limited number of bulk-samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk-samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Buildinq Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report. 3 , ' IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). • One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response-action recommendations for asbestos-containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or a bulk-sample in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a"TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%. V. Inspector Comments Asbestos was identified during the bulk-sampling conducted at 115 Forest Rd, Vail, Colorado. A total of fifteen (15) bulk-samples were collected from the interior and exterior of the above-referenced residence. Eight (8) bulk-samples tested positive greater than 1% for asbestos. 4 ' VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent-asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 115 Forest Rd, Vail, Colorado, on June 29, 2010. The quantities are approximations and are subject to field verification: � ��. .� . .1 � �•. .� . .� Sample #: DW01-01 Sample #: DW01-02 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Bedroom 2 Wall Sample Location: Main Level Bedroom 3 Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: >1,OOOftz <5,OOOftz Material Quantity: >1,OOOftz <5,OOOftz Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White Physical Description (layers): White tape; White compound w/cream paint; White joint compound; compound w/cream paint; White joint compound; White tan dr all White tan dr all Asbestos Content (layers): Negative; Negative; Asbestos Content (layers): Negative; Negative; Ne ative; Ne ative Ne ative; Ne ative Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII � ��. .� . .1 � ��. .� . ., .� Sample #: DW01-03 Sample #: DW01-04 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Bedroom 1 Wall Sample Location: Main Level Kitchen Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: >1,OOOftz <5,OOOftz Material Quantity: >1,OOOftz <S,OOOftz Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White physical Description (layers): Tan compound compound w/cream paint; White joint �,�,�White paint; White compound com ound; White tan d all Asbestos Content (layers): Negative; Negative; 2% Asbestos Content (layers): 2% Chrysotile; 3% Ch sotile; Ne ative Ch sotile Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII 1 1 � . . � � . . � 1 1 � . . � � . � Sample #: DW01-05 Sample #: DW02-01 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Bathroom 4 Wall Sample Location: Lower Level Family Room Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: >1,OOOftz <5,OOOftz Material Quantity: <1,OOOft2 Material Condition: Good Material Condition: Good Physical Description (layers): White compound Physical Description (layers): White texture w/white paint; White tape; White joint w/white paint; White joint compound; White tape; com ound; White tan d all White tan dr all Asbestos Content (layers): Negative; 2% Asbestos Content (layers): Negative; Negative; Ch sotile PC ; Ne ative; 2.5% Ch sotile PC Ne ative; Ne ative Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII � ��. .� . . .1 � ��. .� . ., . � Sample #: DW02-02 Sample #: DW02-03 Sample Description: Drywall Sample Description: Drywall Sample Location: Lower Level Family Room Wall Sample Location: Lower Level Bedroom 5 Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,OOOftz Material Quantity: <1,OOOft2 Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White Physical Description (layers): White tape; White joint compound; White texture w/white paint; joint compound; White texture w/white paint; White tan d all White tan d all Asbestos Content (layers): Negative; Negative; Asbestos Content (layers): Negative; 1.5% Ne ative; Ne ative Ch sotile PC ; 1.75% Ch sotile PC ; Ne ative Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII 1 1 � . . � � . . � 1 1 � . . � ♦ . . � Sample #: DW03-01 Sample #: DW03-02 Sample Description: Drywall Sample Description: Drywall Sample Location: Lower Level Game Room Ceiling Sample Location: Lower Level Game Room Ceiling Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,OOOftz Material Quantity: <1,OOOftz Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White Physical Description (layers): White tape; White joint compound; White texture w/white paint; joint compound; White texture w/white paint; White tan dr all White tan d all Asbestos Content (layers): Negative; 4% Asbestos Content (layers): Negative; 3.25% Ch sotile; 3% Ch sotile; Ne ative Ch sotile PC ; 2.25% Ch sotile PC ; Ne ative Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII � �•. .� . . .1 i �•. .� . .�. Sample #: DW03-03 Sample #: PL01-01 Sample Description: Drywall Sample Description: Plaster Sample Location: Lower Level Game Room Ceiling Sample Location: Exterior Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,OOOft2 Material Quantity: <1,OOOftz Material Condition: Good Material Condition: Good Physical Description (layers): White tape; White physical Description (layers): Gary granular joint compound; White texture w/white paint; plaster; White plaster; White granular plaster White tan dr all Asbestos Content (layers): Negative; 3% Asbestos Content (layers): Negative; Negative; Ch sotile; 3% Ch sotile; Ne ative Ne ative Recommendations: IMMEDIATE - See Section VII Recommendations: GENERAL - See Section VII 1 1 � . . � � . � � � � , . . � � . . � . Sample #: PL01-02 Sample #: PL01-03 Sample Description: Plaster Sample Description: Plaster Sample Location: Exterior Wall Sample Location: Exterior Wall Material Classification: Surfacing Material Material Classifrcation: Surfacing Material Material Quantity: <1,OOOftz Material Quantity: <1,OOOft2 Material Condition: Good Material Condition: Good Physical Description (layers): Tan plaster w/white Physical Description (layers): White plaster aint; Tan ranular laster w white aint; White ranular laster Asbestos Content (layers): Negative; Negative Asbestos Content (layers): Negative; Negative Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII � ��. .� . .� Sample #: FT01-01 Sample Description: Floor Tile Sample Location: Lower Level Family Room Floor Material Classification: Miscellaneous Material Material Quantity: <1,OOOftz Material Condition: Good Physical Description (layers): Black mastic; Red Floor Tile Asbestos Content (layers): Negative; 2% Ch sotile Recommendations: IMMEDIATE - See Section VII VII. Recommendations IMMEDIATE: The laboratory results of the potential ACM sampled at 115 Forest Rd, Vail, Colorado, on June 29, 2010, indicate that eight (8) bulk-samples of drywall and resilient floor tile collected from the resident were reported as positive for asbestos greater than 1% Chrysotile. If the above-referenced ACM is to be removed from the residence and the total quantity exceeds any of the regulatory trigger levels of 50 linear feet on pipes, 32 square feet on other surfaces, or the volume equivalent of a 55-gallon drum, a Colorado-licensed asbestos abatement contractor is required to perform the removal, including formal notification to the Colorado Department of Public Health and Environment prior to the abatement of the ACM. 8 APPENDIX A SAMPLE LOCATIONS Living Rnam � Kitchen DW01•04 Batfiroom 1 (� ��� dW01-03 SLorage � � Bathrnom 4 Bedro�om 1 �) �� ��L "image not to scale, approximate 10 Bedcoom 2 Bathmom 2J3 Bedr�om 3 Bedraom4 1-0� -01 DWill-OZ LOWER LfiVEL DW03-03 • pt,al-ol Bedmom S DW02•03 Laundrq Rnom I) II Badu+oom 5 PL01-Q2 Game Room I�--�—i II F'T� •01 DW03-02 � Bathroom 6 DW42-02 P401-03 � Family Roam �DW03-02 II U�� �m () DW02-01 'image not to scale, apprniadmate 11 APPENDIX B CERTIFICATION APPENDIX C LABORATORY ANALYSIS 12 � � � �� ; � ,� �; �; �: �, �" �" F�'�.�-:.i:. . ��� HERUUIULC?Cjy LJ�IUURATURy --„��� ASSOCIATES, INCORPORATED `` COfVSULTING LABORATORY Certi�cate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloav.net ClientName DS Consulting, Inc. ������ Date Collected: 06/29/]0 Street address 5366 Flatrock Ct. fl Date Received: 06/30/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10 Attn: Steve Shurtliff #200860-0 Date Reported: 07/07/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition 98% 104456-1A White Tape N 4,5% Negative CELL 2 104456-1B White Compound w/ Cream Paint N 4,5% Negative 100 C DWO1-01 104456-1C White Joint Compound N 4,10% Negative 100 C 10% 104456-1D White/Tan Drywall N 4,80% Negative CELL 90 98% 104456-2A White Tape N 4,5% Negative CELL 2 104456-2B White Compound w/ Cream Paint N 4,5% Negative 100 C DWO1-02 104456-2C White Joint Compound N 4,10% Negative 100 C 10% 104456-2D White/Tan Drywall N 4,80% Negative CELL 90 98% 104456-3A White Tape N 4,10% Negative CELL 2 DWO1-03 POSITIVE 104456-3B White Compound w/ Cream Paint N 4,10% 2% CHRY 98 C , i/��{�i��2Y G�r�� � % i e c aum ce e Laboratory Analyst �'�l�,�--�-.._._____.-__�_._ __ .. f Adam Aumphreys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysoti(e CR = Croc�dolite TR = Tremolite Trace=Less Than 1 % CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques �� ` HERUUIULGIti�/ LAUURATUR�/ -•`--� ASSOCIAiES, INC4RPORATED �` CONSUUING U80RATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloav.net Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10 Street address 5366 Flatrock Ct. � Date Received: 06/30/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10 Attn: Steve Shurtliff #200860-o Date Reported: 07/07/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition POSITIVE 104456-3C White Joint Compound N 4,15% 2% CHRY 98 C DWO1-03 10% 104456-3D White/Tan Drywall N 4,65% Negative CELL 90 POSITIVE 104456-4A Tan Compound w/ White Paint N 2,30% 2% CHRY 98 C DWO1-04 POSITIVE 104456-4B White Compound N 2,70% 3% CHRY 97 C POSITIVE 104456-SA White Compound w/ White Paint N 4,5% 3% CHRY 97 C 98% 104456-SB White Tape N 4,5% Negative CELL 2 DWO1-OS POSITIVE 104456-5C White Joint Compound N 4,15% 3% CHRY 97 C 50% 104456-SD White/Tan Drywall N 4,75% Negative CELL 50 104456-6A White Texture w/ White Paint N 4,10% Negative 100 C DW02-O 1 104456-6B White Joint Compound N 4,10% Negative 100 C f���� ���� % � e c aum oe e Laboratory Analyst G-�/'�� � �'�.�---� --_ _ � Adam Humplireys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1% CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques �\ HERUUIULUCjy 1�1UORAT�R)/ --��-� ASSOCWTES, INCQRPORATED �` CONSUUING LABORATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloav.net Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10 Street address 5366 Flatrock Ct. fl Date Received: 06/30/]0 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10 Attn: Steve ShuRliff #200860-0 Date Reported: 07/07/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition 98% 104456-6C White Tape N 4,10% Negative CELL 2 DW02-O 1 10% 104456-6D White/Tan Drywall N 4,70% Negative CELL 90 98% 104456-7A White Tape N 4,5% Negative CELL 2 104456-7B White Joint Compound N 4,5% Negative 100 C DW02-02 104456-7C White Texture w/ White Paint N 4,15% Negative 100 C 10% 104456-7D White/Tan Drywall N 4,75% Negative CELL 90 98% 104456-8A White Tape N 4,5% Negative CELL 2 POSITIVE 104456-8B White Joint Compound N 4,5% 3% CHRY 97 C DW02-03 POSITIVE 104456-8C White Texture w/ White Paint N 4,15% 2% CHRY 98 C 10% 104456-8D White/Tan Drywall N 4,75% Negative CELL 90 :.��,�i���.,-�'�� ✓ � i e c aum oe e Laboratory Analyst .,. %�'��/G� c �....-___------ --_-_ G-.1�j r %'� Adam Humplireys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1% CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques ��fiERUUIUIUCiy LAUURATfJR�/ --.,�--� ASSOCIATES, INC4RPORATED `` CONSUITING UBORATORY Certificate of Analysis 13949 W. Colfax Ave sU�te zos Lakewood, CO 80401 303.232.?r746 www.aerobioloav.net Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10 Street address 5366 Flatrock Ct. fl Date Received: 06/30/10 City, State ZIP Monison, CO 80465 Date Analyzed: 07/07/10 Attn: Steve Shurtliff #200860-0 Date Reported: 07/07/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Buiiding Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additioaal Comments es/no La ers % area % area % com sition 98% 104456-9A White Tape N 4,10% Negative CELL 2 POSITIVE 104456-9B White Joint Compound N 4,10% 4% CHRY 96 C DW03-01 POSITIVE 104456-9C White Texture w/ White Paint N 4,15% 3% CHRY 97 C 50% 104456-9D White/Tan Drywall N 4,65% Negative CELL 50 98% 104456-10A White Tape N 4,10% Negative CELL 2 POSITIVE 104456-1OB White Joint Compound N 4,10% 4% CHRY 96 C DW03-02 POSITIVE 104456-1OC White Texture w/ White Paint N 4,15°/a 3% CHRY 97 C 70% 104456-1OD White/Tan Drywall N 4,65% Negative CELL 30 98% 104456-11A White Tape N 4,5% Negative CELL 2 DW03-03 POSITIVE 104456-11B White Joint Compound N 4,5% 3% CHRY 97 C ✓ �t �� `%' '� � i e c aum oe e Laboratory Analyst �`�,-/: �---�-.._..-______-. _ � A� m Aumphreys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1 % CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T=Tar P = Perlite O = Organic B = Binder OP = Opaques ��_HERUUIUIU(.�y LAUURATUIty � IYJSIJ�W, W� �NliO��Rl1�� CONSUUING U80RATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.�746 www.aerobioloav.net Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10 Street address 5366 Flatrock Ct. fl Date Received: 06/30/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10 Attn: Steve Shurtliff �200860-0 Date Reported: 07/07/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition POSITIVE 104456-11C White Texture w/ White Paint N 4,10% 3% CHRY 97 C DW03-03 50% 104456-11D White/Tan Drywall N 4,80% Negative CELL 50 104456-12A Gray Granular Plaster N 3,10% Negative 100 C PLO1-01 104456-12B White Plaster N 3,30% Negative 100 C 104456-12C White Granular Plaster N 3,60% Negative 100 C 104456-13A Tan plaster w/ White Paint N 2,2% Negative 100 C PLO 1-02 � 104456-13B Tan Granular Plaster N 2,98% Negative 100 C 104456-14A White Plaster w/ White Paint N 2,1% Negative 100 C PLO 1-03 104456-14B White Granular Plaster N 2,99% Negative 100 C FTO1-01 104456-15A Black Mastic N 2,2% Negative 100 B f����,����,� % i e c aum oe e Laboratory Analyst % �� f:,�f� ��,.-----------_ _- G- , � r' ��, --_ _ am Humphrey§ Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1 % CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques ��: AERUUIULUCjy LAUURATURy -..�-•` ASSOCIATES, INCORPORATED �` CANSULTING LABORATORY Certifcate of Analysis 13949 W. Colfa�c Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloav.net Client Name DS Consulting, Inc. _^����� Date Collected: 06/29/10 Street address 5366 Flatrock Ct. w � Date Received: 06/30/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10 Attn: Steve Shurtliff #200860-o Date Reported: 07/07/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homa Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition POSITIVE FTOI-01 104456-15B Red Floor Tile N 2,98% 2% CHRY 98 B f�.���i��--�' � i e c aum oe e Laboratory Analyst �''�,,,--�/„2---�-,.______..-- w.__._.__`_ � AdamNumpTireys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1 % CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques `�`HERUUIULUCjy LAUURATUR)/ --�„�-� ASSOCIATES, INCORPORATED `` CANSUUING LA80RATORY Certificate of Analysis 13949 W. Colfaz Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloqv.net Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10 Street address 5366 Flatrock Ct. fl Date Received: 06/30/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/14/10 Attn: Steve Shurtliff #200860-0 Date Reported: 07/14/10 Client Project Name: 115 Forest Rd. Vail, CO Project ID: ]04456 Job ID: POINT COUNT Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Homa Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix Sam le Identification Physical Description of Sample; geneous of Fibers Material Material Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition POSITIVE 104456-SA White Compound w/ White Paint N 100% 2% CHRY DWO1-OS POSITIVE 104456-SC White Joint Compound N 100% 2.5% CHRY POSITIVE 104456-8B White Joint Compound N 100% 1.5% CHRY DW02-03 POSITIVE 104456-8C White Texture w/ White Paint N 100% 1.75% CHRY POSITIVE 104456-1OB White Joint Compound N 100% 3.25% CHRY DW03-02 POSITIVE 104456-1OC White Texture w/ White Paint N 100% 2.25% CHRY /����i���� ��✓�/ % J / � e c aum oe e Laboratory Analyst / /� .-�"`___----_.._...__. _ c� Adam7-Iumplireys Asbestos Laboratory Supervisor A = Amosite AC = Actinolite AN = Anthophyllite CHRY=Chrysotile CR = Crocidolite TR = Tremolite Trace=Less Than 1 % CELL = Cellulose MW = Mineral Wool FBG = Fiberglass SYN = Synthetic WO = Wollastonite NTR = Non-Asbestiform TR NAC = Non-Asbestiform AC FT = Fibrous Talc AH = Animal Hair Q = Quartz C = Carbonates V = Vertniculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques �AEROb10I.00.�y LAbORATOR}/ -`-` ASSOCIATES, INCORPORATED `` CONSl1�nNG LABURATORY Certificate of Analysis DS Consulting, Inc. 5366 Flatrock Ct. Morrison, CO 80465 Steve Shurtliff Client Project Name: General Notes 115 Forest Rd. Vail, CO ♦ lYegative indicates no asbestos was detected; the method detection limit is 1%. avdQ�. N200860-0 ♦ Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1%. 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 3032323746 www.aerobioloav.net Date Collected: O6/29/10 Date Received: 06/30/10 Date Analyzed: 07/07/10 Date Reported: 07/07/10 Project ID: 104456 Job ID: ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestiform variety of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. Eor such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM floor tile analysis is accepted under the NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, [nc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the retum of any samples. Notes Reauired bv NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ♦ This test repod relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP-approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.2323746