HomeMy WebLinkAboutD10-0002D10-0002: Entries for Item:90 - BLDG-Final 08:43 01/17/2013
Action Comments By Date Unique_
Ke
AP jrm 01/18/2012 A000148
620
Total Rows: 1
Page 1
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
Job Address:
Location.......:
Parcel No....:
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
DEMO. OF PART/ALL BLDG.
115 FOREST RD VAIL
115 FOREST ROAD
210107113030
OWNER 115 COMPANY
4960 S LAFAYETTE LN
ENGLEWOOD
CO 80113
APPLICANT BECK BUILDING COMPANY
P.O. BOX 4030
VAIL
CO 81658
License: 117-A
CONTRACTOR BECK BUILDING COMPANY
P.O. BOX 4030
VAIL
CO 81658
License: 117-A
Desciption:
DEMO HOUSE
0�/23/2oio
Permit # D10-0002
Project # ??
Status . . . .
Applied .. . :
Issued . . . :
Expires.....:
ISSUED
07/23/2010
08/24/2010
02/20/2011
07/23/2010 Phone: 970-949-1800
07/23/2010 Phone: 970-949-1800
Occupancy: R3 Single Family Residence
Type Construction: VB
Valuation: $48,000.00 Revision Valuation: ??
Total Sq Ft Added: 0
*s*�»s*s**+s***ssa*sr*s►s*+�ssss+s�s+s+�++�+s+ss*�**st*+***********s FEE SUMMARY :�+►+s+�s+ss**s****+**a****s*+s+**a*s++srs+ss�+sa3++s3+s+s+s
Building----> $623 . 55 Restuarant Plan Review—> $o . oo Total Calculated Fees—> $1, 032. 86
Plan Check---> $ 4 0 5. 31 Recreation Fee------------> $ 0. 0 0 Additional Fees----> $ 0. 0 0
Investigation-> $ 0. 0 0 TOTAL FEES-----------> $1, 0 3 2. 86 Total Permit Fee-----> $1, 03 2. 86
W il I Call-----> $ 4. 0 0 Payments------------------> $1, 0 3 2. 8 6
BALANCE DUE----> $ o. o 0
##i*###*#s##**##R##4###tt###t##+######R###�###+#►+#4#i4#+#####4#*##�Ft*+##*#########t####t####4#t###►+##+#+#i+ft#R4##t###*rt#s#sstsst#s*#a*#sR*ssss
Approvals:
Item: 05100 BUILDING DEPARTMENT
08/04/2010 jrm Action: AP
Item: 05400 PLANNING DEPARTMENT
07/29/2010 bgibson Action: AP see conditions.
plans routed to JR Mondragon.
Item: 05600 FIRE DEPARTMENT
08/05/2010 drhoades Action: DN Asbestos
permit/abatement/final air clearance needed prior to demo
permit approval. Contractor was notified (Matt, 376-4447)
and is aware of this fact.
#######k##*####i##*###��#t##►#tt###*#####*###############*k�###t4f+f4#4t#4#i##*#*###############t#fk#f##it#t#i###################ff#4#f#*##4ii►ti
See the Conditions section of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM •
4 PM. i9►� � �`�
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit #: D10-0002 as of 08-24-2010 Status: ISSUED
********************************************************************************************************
Permit Type:
Applicant:
08/24/2010
Job Address:
Location:
Parcel No:
DEMO. OF PART/ALL BLDG.
BECK BUILDING COMPANY
970-949-1800
115 FOREST RD VAIL
115 FOREST ROAD
210107113030
Description:
DEMO HOUSE
Applied: 07/23/2010
Issued:
To Expire: 02/20/2011
***********************************************Conditions:************************************************
Cond: 38
(BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY.
AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE
FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK
OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT
THE VAIL FIRE DEPARTMENT AT 479-2252.
Cond: 1
(FIRE): FIlZE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORK CAN BE STARTED.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIlZED TO CHECK FOR CODE
COMPLIANCE.
Cond: CON0011543
The applicant shall re-grade and re-vegetate the site to a
natural state within 14 days of completing demolition if a
building permit for the proposed new residence has not been
obtained and construction is being diligently pursued.
***r****+****�****s******�*************��**�***********************************************s
TOWN OF VAIL, COLORADO Statement
*«***********+****«**��**********************�**��*********�******************+**********�**
Statement Number: R100001144 Amount: $1,032.86 08/24/201011:47 AM
Payment Method: Check Init: JRM
Notation:
-----------------------------------------------------------------------------
Permit No: D10-0002 Type: DEMO. OF PART/ALL BLDG.
Parcel No: 2101-071-1303-0
Site Address: 115 FOREST RD VAIL
Location: 115 FOREST ROAD
Total Fees: $1,032.86
This Payment: $1,032.86 Total ALL Pmts: $1,032.86
Balance: $0.00
*ts******r*************�*********�******************+*********+*****************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 623.55
PF 00100003112300 PLAN CHECK FEES 405.31
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
-----------------------------------------------------------------------------
Separate
�TNG PERMIT APPLICATION
e���-t`o�.
� required for electrical, piumbing, mechanicai, fireplace, etc.
Project Street Address:
I f � ��-es��
(Number) (Street) (Suite #)
Building/Complex Name:
Contractor Information:
Company: e c.� � i��� tia ��J i,,.��n�
Company Address: ��tic ��� � Detailed Scope and Location of Work: ��
{� " G,O�s
City: �s`i � State: � Zip: �,� ,� � �,�r�
Contact Name: V�� � D�Z�T�t
Contact Phone: l� – °(�{ G '� (C6'pD
(1 ��� � r� (use additional sheet if necessary)
E-Mail �elsi.� oJ s c,� � S• �r�
l��_ � Work Class: ,
: Town of Vail Contractor Registration No.: � New Addition p�
( ) ( ) Remodel ( ) Repair ( ) Other
_ , `\.
X Work Type
Contractor Signature (required) Interior O Exterior O Both (�
Property Infortnation TYPe of Building: ,
Parcel #: � �� �'� C�7 i — � �-- C53� Single-Family� Duplex ( ) Multi-Family ( )
(For parcel #, contact Eagle County Assessors Office at 970-328-8640 or Commercial Other
visit www.eaglecounty.us/patie) � ) � )
Tenant Name: ; Does a Fire Alarm Exist? Yes O No �j
Owner Name: %�� �t�..� a.. y Monitored Alarm? Yes O No (�
� Does a Sprinkler System Exist? Yes O No (�
IOffice Use: � n ��� � � ` �,�
Project #: , ��L
DRB #:
Building P i
Lot #: Block Subdivisi . _
ns (Labor & Materials)
c^' _ -_ j ,'; �/' � ,� I
`�� i� r -, 1�����
(including firepl�ce)
ti,i�
�� .,_..._ �
Total:
vr •
# 8� Type of Existing Fireplaces: Gas Appliances
Gas Log Wood/Pellet Wood Buming �_
#& Type of Proposed Fireplaces: Gas Appliances
Gas Log Wood/Pellet Wood Burning _
�-%� !�!.'7� �� .. . .
� �' � J?.114 � � � ���
��
,
Fl
O1-Jan-10
Asbestos Inspection and Sampling Report
115 Forest Rd, Vail, Colorado 81657
Presented to:
Mr. Kevin 0'Donnell
Beck Building Company
PO Box 4030
Vail, CO 81658
Performed & Prepared by:
Mr. Steve Shurtliff
DS Consulting, Inc.
P.O. Box 6864
Avon, CO 81620
(303) 378-1544
Project Details:
DSC Project #: 2435
Conducted: June 29, 2010
� C�nsultin
g
� � �
O
EXECUTIVE SUMMARY
On June 29, 2010, Mr. Steve Shurtliff of DS Consulting, Inc. (DSC) performed a full building inspection and
collected asbestos bulk-samples at 115 Forest Rd, Vail, Colorado, in order to identify potentially
hazardous friable and non-friable asbestos-containing materials (ACM) within the above-referenced,
single-family residence scheduled for full demolition. The Colorado Department of Public Health and
Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (ACM) as a material
containing more than 1% asbestos.
Mr. Shurtliff performed asbestos bulk-sampling of multiple varieties of drywall (surfacing materials) in a
total of eleven (11) locations within the upper and lower level, plaster (surfacing material) in a total of
three (3) locations on the exterior of the residence and resilient floor tile (miscellaneous material) in a
total of one (1) location within the lower level (see AppendixA for sample locations).
All fifteen (15) bulk-samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP
#200860-0) in Denver, Colorado with eight (8) laboratory results initially reporting positive for asbestos
between 1.5% and 4% Chrysotile (see Appendix C for laboratory results). The bulk-sample with the
highest percentage of asbestos within each homogeneous group was then re-analyzed using the point-
count method to determine the exact percentage of asbestos within the sample in order to verify it's
percentage of asbestos was greater than 1%. All three (3) bulk-samples re-analyzed by the point-count
method were reported as containing greater than 1% Chrysotile asbestos.
The following sampled materials were found to contain asbestosgreater than 1%(ACM):
� �
�
� � � � �
Drywall Upper Level Surfacing >1,OOOftz o
DW01-03 Type 1 Bedroom 1 Material Friable �S,OOOft2 Good 2/o Chrysotile
Drywall Upper Level Surfacing >1 OOOftz 2% - 3%
DW01-04 Type 1 Kitchen Material Friable �S,OOOftz Good Chrysotile
Drywall Upper Level Surfacing >1,OOOftz 2% - 2.5%
DW01-05 Type 1 Bathroom 4 Material Friable �5,OOOft2 Good Chrysotile
PC
Drywall Lower Level Surfacing
1.5% -1.75%
DW02-03 Type 2 Bedroom 5 Material Friable <1,OOOft2 Good Chrysotile
PC
DW03-01 Drywall Lower Level Surfacing Friable <1,OOOftz Good 3% - 4%
Type 3 Game Room Material Chrysotile
Drywall Lower Level Surfacing
3.25% - 2.25%
DW03-02 Type 3 Game Room Material Friable <1,OOOftz Good Chrysotile
PC
DW03-03 Drywall Lower Level Surfacing Friable <1,OOOftz Good 3% Chrysotile
Type 3 Game Room Material
FT01-01 Resilient Lower Level Miscellaneous Non- �1,OOOftz Good 2% Chrysotile
Floor Tile Family Room Material Friable
"Quantities are approximations and subject to field verification. PC=point-count
2
PROjECT OVERVIEW
I. Introduction
A full building inspection and bulk-sampling for ACM was conducted at 115 Forest Rd, Vail, Colorado, by
Mr. Shurtliff on June 29, 2010, at the request of Mr. Kevin 0'Donnell with Beck Building Company. Mr.
Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix
B for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous
friable and non-friable ACM within the residence.
II. Structural Design
The structure is a wood-framed, two-level, single-family residence.
III. Sampling and Analytical Procedures
The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building
Inspector qualified by experience, education and training in the recognition of potential ACM and
approved bulk-sampling techniques. The asbestos bulk-sampling was conducted on suspect ACM with a
limited number of bulk-samples being collected within the residence.
The inspection, assessment and sampling were performed in accordance with Environmental Protection
Agency/AHERA recommended procedures. These procedures call for the visual inspection of the area of
concern and the collection and analysis of representative bulk-samples of suspect material.
Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not
broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be
located in these and other inaccessible areas.
Random bulk-samples, representative of the suspect asbestos-containing building materials (ACBM) of
each homogeneous area (HA), were collected according to the guidelines published as Environmental
Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections
2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the
following criteria:
1. The distribution of the suspect material throughout the HA.
2. The suspect material's physical characteristics and application.
3. Random sampling patterns determined for each HA.
Suspect materials sampled and analyzed should be considered to be representative of materials in each
HA if they exhibit similar physical characteristics and the application of the sampled material can be
correlated to the application of un-sampled material. Bulk-samples collected were analyzed utilizing the
EPA's Method for the Determination of Asbestos in Bulk Buildinq Materials (EPA 600/R/116, July, 1993)
and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the
bulk-samples was performed on the "date reported," as listed in the bulk-sample analysis report.
3
,
' IV. Notes on Report Format
Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were
divided into three classifications:
1. Surfacing Material: sprayed or troweled onto structural building member.
2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation.
3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/linoleum, ceiling tiles,
insulation, and finishing materials.
Condition assessments were performed by the accredited inspector at the time of inspection. Condition
assessments are listed in the following section. Ratings of "good," "damaged," and "significantly
damaged" are meant to indicate the overall condition of the material.
A material in "good" condition has no visible damage or deterioration, or showing only very limited
damage or deterioration.
A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered,
water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the
damage is evenly distributed (one-quarter if the damage is localized). Accumulation of powder, dust or
debris similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence. A material in "significantly damaged" condition has one or more of the following
characteristics:
• The surface is crumbling or blistered over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized).
• One-tenth (one-quarter, if localized) of the material is hanging from the surface, deteriorated, or
showing adhesive failure.
• Water stains, gouges, or mars are over at least one-tenth of the surface if the damage is evenly
distributed (one-quarter if the damage is localized). Accumulation of powder, dust or debris
similar in appearance to the suspect material on surfaces beneath the material can be used as
confirmatory evidence.
Response-action recommendations for asbestos-containing HAs are listed in the section VII.
Recommendations may be for more than one HA, if materials are alike. Recommendations are either
"general" or "immediate." An immediate recommendation indicates the presence of asbestos greater
than 1% within the bulk-sample, or a bulk-sample in the same HA, and should be addressed accordingly.
A general recommendation indicates asbestos does not exist greater than 1% within the bulk-sample, or
a bulk-sample in the same HA, and no further abatement activities are required for removal of the
material. Any sample reporting a"TRACE" amount of asbestos must be considered to be positive for
asbestos greater than 1% unless it is analyzed by the point-count method to be less than 1%.
V. Inspector Comments
Asbestos was identified during the bulk-sampling conducted at 115 Forest Rd, Vail, Colorado. A total of
fifteen (15) bulk-samples were collected from the interior and exterior of the above-referenced
residence. Eight (8) bulk-samples tested positive greater than 1% for asbestos.
4
' VI. Homogeneous Area Descriptions
The following section contains sampled HA descriptions and sample locations. Percent-asbestos content
for each sample indicated can vary depending on sample locations, homogeneity of the materials, and
type of application. The following samples were collected from the single family residence at 115 Forest
Rd, Vail, Colorado, on June 29, 2010. The quantities are approximations and are subject to field
verification:
� ��. .� . .1 � �•. .� . .�
Sample #: DW01-01 Sample #: DW01-02
Sample Description: Drywall Sample Description: Drywall
Sample Location: Main Level Bedroom 2 Wall Sample Location: Main Level Bedroom 3 Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: >1,OOOftz <5,OOOftz Material Quantity: >1,OOOftz <5,OOOftz
Material Condition: Good Material Condition: Good
Physical Description (layers): White tape; White Physical Description (layers): White tape; White
compound w/cream paint; White joint compound; compound w/cream paint; White joint compound;
White tan dr all White tan dr all
Asbestos Content (layers): Negative; Negative; Asbestos Content (layers): Negative; Negative;
Ne ative; Ne ative Ne ative; Ne ative
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
� ��. .� . .1 � ��. .� . ., .�
Sample #: DW01-03 Sample #: DW01-04
Sample Description: Drywall Sample Description: Drywall
Sample Location: Main Level Bedroom 1 Wall Sample Location: Main Level Kitchen Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: >1,OOOftz <5,OOOftz Material Quantity: >1,OOOftz <S,OOOftz
Material Condition: Good Material Condition: Good
Physical Description (layers): White tape; White physical Description (layers): Tan compound
compound w/cream paint; White joint �,�,�White paint; White compound
com ound; White tan d all
Asbestos Content (layers): Negative; Negative; 2% Asbestos Content (layers): 2% Chrysotile; 3%
Ch sotile; Ne ative Ch sotile
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
1 1 � . . � � . . � 1 1 � . . � � . �
Sample #: DW01-05 Sample #: DW02-01
Sample Description: Drywall Sample Description: Drywall
Sample Location: Main Level Bathroom 4 Wall Sample Location: Lower Level Family Room Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: >1,OOOftz <5,OOOftz Material Quantity: <1,OOOft2
Material Condition: Good Material Condition: Good
Physical Description (layers): White compound Physical Description (layers): White texture
w/white paint; White tape; White joint w/white paint; White joint compound; White tape;
com ound; White tan d all White tan dr all
Asbestos Content (layers): Negative; 2% Asbestos Content (layers): Negative; Negative;
Ch sotile PC ; Ne ative; 2.5% Ch sotile PC Ne ative; Ne ative
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
� ��. .� . . .1 � ��. .� . ., . �
Sample #: DW02-02 Sample #: DW02-03
Sample Description: Drywall Sample Description: Drywall
Sample Location: Lower Level Family Room Wall Sample Location: Lower Level Bedroom 5 Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOftz Material Quantity: <1,OOOft2
Material Condition: Good Material Condition: Good
Physical Description (layers): White tape; White Physical Description (layers): White tape; White
joint compound; White texture w/white paint; joint compound; White texture w/white paint;
White tan d all White tan d all
Asbestos Content (layers): Negative; Negative; Asbestos Content (layers): Negative; 1.5%
Ne ative; Ne ative Ch sotile PC ; 1.75% Ch sotile PC ; Ne ative
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
1 1 � . . � � . . � 1 1 � . . � ♦ . . �
Sample #: DW03-01 Sample #: DW03-02
Sample Description: Drywall Sample Description: Drywall
Sample Location: Lower Level Game Room Ceiling Sample Location: Lower Level Game Room Ceiling
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOftz Material Quantity: <1,OOOftz
Material Condition: Good Material Condition: Good
Physical Description (layers): White tape; White Physical Description (layers): White tape; White
joint compound; White texture w/white paint; joint compound; White texture w/white paint;
White tan dr all White tan d all
Asbestos Content (layers): Negative; 4% Asbestos Content (layers): Negative; 3.25%
Ch sotile; 3% Ch sotile; Ne ative Ch sotile PC ; 2.25% Ch sotile PC ; Ne ative
Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII
� �•. .� . . .1 i �•. .� . .�.
Sample #: DW03-03 Sample #: PL01-01
Sample Description: Drywall Sample Description: Plaster
Sample Location: Lower Level Game Room Ceiling Sample Location: Exterior Wall
Material Classification: Surfacing Material Material Classification: Surfacing Material
Material Quantity: <1,OOOft2 Material Quantity: <1,OOOftz
Material Condition: Good Material Condition: Good
Physical Description (layers): White tape; White physical Description (layers): Gary granular
joint compound; White texture w/white paint; plaster; White plaster; White granular plaster
White tan dr all
Asbestos Content (layers): Negative; 3% Asbestos Content (layers): Negative; Negative;
Ch sotile; 3% Ch sotile; Ne ative Ne ative
Recommendations: IMMEDIATE - See Section VII Recommendations: GENERAL - See Section VII
1 1 � . . � � . � � � � , . . � � . . � .
Sample #: PL01-02 Sample #: PL01-03
Sample Description: Plaster Sample Description: Plaster
Sample Location: Exterior Wall Sample Location: Exterior Wall
Material Classification: Surfacing Material Material Classifrcation: Surfacing Material
Material Quantity: <1,OOOftz Material Quantity: <1,OOOft2
Material Condition: Good Material Condition: Good
Physical Description (layers): Tan plaster w/white Physical Description (layers): White plaster
aint; Tan ranular laster w white aint; White ranular laster
Asbestos Content (layers): Negative; Negative Asbestos Content (layers): Negative; Negative
Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII
� ��. .� . .�
Sample #: FT01-01
Sample Description: Floor Tile
Sample Location: Lower Level Family Room Floor
Material Classification: Miscellaneous Material
Material Quantity: <1,OOOftz
Material Condition: Good
Physical Description (layers): Black mastic; Red
Floor Tile
Asbestos Content (layers): Negative; 2%
Ch sotile
Recommendations: IMMEDIATE - See Section VII
VII. Recommendations
IMMEDIATE:
The laboratory results of the potential ACM sampled at 115 Forest Rd, Vail, Colorado, on June 29, 2010,
indicate that eight (8) bulk-samples of drywall and resilient floor tile collected from the resident were
reported as positive for asbestos greater than 1% Chrysotile.
If the above-referenced ACM is to be removed from the residence and the total quantity exceeds any of
the regulatory trigger levels of 50 linear feet on pipes, 32 square feet on other surfaces, or the volume
equivalent of a 55-gallon drum, a Colorado-licensed asbestos abatement contractor is required to
perform the removal, including formal notification to the Colorado Department of Public Health and
Environment prior to the abatement of the ACM.
8
APPENDIX A
SAMPLE LOCATIONS
Living Rnam
�
Kitchen
DW01•04
Batfiroom 1 (� ���
dW01-03
SLorage
�
�
Bathrnom 4
Bedro�om 1 �) �� ��L
"image not to scale, approximate
10
Bedcoom 2
Bathmom 2J3
Bedr�om 3
Bedraom4
1-0�
-01
DWill-OZ
LOWER LfiVEL
DW03-03
•
pt,al-ol
Bedmom S
DW02•03
Laundrq Rnom I) II Badu+oom 5
PL01-Q2
Game Room I�--�—i II F'T� •01
DW03-02
�
Bathroom 6
DW42-02
P401-03
�
Family Roam
�DW03-02 II U�� �m () DW02-01
'image not to scale, apprniadmate
11
APPENDIX B
CERTIFICATION
APPENDIX C
LABORATORY ANALYSIS
12
�
�
�
��
;
�
,�
�;
�;
�:
�,
�"
�"
F�'�.�-:.i:. .
��� HERUUIULC?Cjy LJ�IUURATURy
--„��� ASSOCIATES, INCORPORATED
`` COfVSULTING LABORATORY
Certi�cate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.2323746
www.aerobioloav.net
ClientName DS Consulting, Inc. ������ Date Collected: 06/29/]0
Street address 5366 Flatrock Ct. fl Date Received: 06/30/10
City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10
Attn: Steve Shurtliff #200860-0 Date Reported: 07/07/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition
98%
104456-1A White Tape N 4,5% Negative CELL 2
104456-1B White Compound w/ Cream Paint N 4,5% Negative 100 C
DWO1-01
104456-1C White Joint Compound N 4,10% Negative 100 C
10%
104456-1D White/Tan Drywall N 4,80% Negative CELL 90
98%
104456-2A White Tape N 4,5% Negative CELL 2
104456-2B White Compound w/ Cream Paint N 4,5% Negative 100 C
DWO1-02
104456-2C White Joint Compound N 4,10% Negative 100 C
10%
104456-2D White/Tan Drywall N 4,80% Negative CELL 90
98%
104456-3A White Tape N 4,10% Negative CELL 2
DWO1-03 POSITIVE
104456-3B White Compound w/ Cream Paint N 4,10% 2% CHRY 98 C
, i/��{�i��2Y G�r��
� %
i e c aum ce e
Laboratory Analyst
�'�l�,�--�-.._._____.-__�_._ __ ..
f
Adam Aumphreys
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysoti(e
CR = Croc�dolite
TR = Tremolite
Trace=Less Than 1 %
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vermiculite
G = Gypsum
M = Mica
T = Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
�� ` HERUUIULGIti�/ LAUURATUR�/
-•`--� ASSOCIAiES, INC4RPORATED
�` CONSUUING U80RATORY
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.2323746
www.aerobioloav.net
Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10
Street address 5366 Flatrock Ct. � Date Received: 06/30/10
City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10
Attn: Steve Shurtliff #200860-o Date Reported: 07/07/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition
POSITIVE
104456-3C White Joint Compound N 4,15% 2% CHRY 98 C
DWO1-03
10%
104456-3D White/Tan Drywall N 4,65% Negative CELL 90
POSITIVE
104456-4A Tan Compound w/ White Paint N 2,30% 2% CHRY 98 C
DWO1-04
POSITIVE
104456-4B White Compound N 2,70% 3% CHRY 97 C
POSITIVE
104456-SA White Compound w/ White Paint N 4,5% 3% CHRY 97 C
98%
104456-SB White Tape N 4,5% Negative CELL 2
DWO1-OS
POSITIVE
104456-5C White Joint Compound N 4,15% 3% CHRY 97 C
50%
104456-SD White/Tan Drywall N 4,75% Negative CELL 50
104456-6A White Texture w/ White Paint N 4,10% Negative 100 C
DW02-O 1
104456-6B White Joint Compound N 4,10% Negative 100 C
f���� ����
%
� e c aum oe e
Laboratory Analyst
G-�/'�� � �'�.�---� --_ _
�
Adam Humplireys
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysotile
CR = Crocidolite
TR = Tremolite
Trace=Less Than 1%
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vermiculite
G = Gypsum
M = Mica
T = Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
�\ HERUUIULUCjy 1�1UORAT�R)/
--��-� ASSOCWTES, INCQRPORATED
�` CONSUUING LABORATORY
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.2323746
www.aerobioloav.net
Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10
Street address 5366 Flatrock Ct. fl Date Received: 06/30/]0
City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10
Attn: Steve ShuRliff #200860-0 Date Reported: 07/07/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition
98%
104456-6C White Tape N 4,10% Negative CELL 2
DW02-O 1 10%
104456-6D White/Tan Drywall N 4,70% Negative CELL 90
98%
104456-7A White Tape N 4,5% Negative CELL 2
104456-7B White Joint Compound N 4,5% Negative 100 C
DW02-02
104456-7C White Texture w/ White Paint N 4,15% Negative 100 C
10%
104456-7D White/Tan Drywall N 4,75% Negative CELL 90
98%
104456-8A White Tape N 4,5% Negative CELL 2
POSITIVE
104456-8B White Joint Compound N 4,5% 3% CHRY 97 C
DW02-03 POSITIVE
104456-8C White Texture w/ White Paint N 4,15% 2% CHRY 98 C
10%
104456-8D White/Tan Drywall N 4,75% Negative CELL 90
:.��,�i���.,-�'��
✓ �
i e c aum oe e
Laboratory Analyst
.,. %�'��/G� c �....-___------ --_-_
G-.1�j
r
%'�
Adam Humplireys
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysotile
CR = Crocidolite
TR = Tremolite
Trace=Less Than 1%
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vermiculite
G = Gypsum
M = Mica
T = Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
��fiERUUIUIUCiy LAUURATfJR�/
--.,�--� ASSOCIATES, INC4RPORATED
`` CONSUITING UBORATORY
Certificate of Analysis
13949 W. Colfax Ave
sU�te zos
Lakewood, CO 80401
303.232.?r746
www.aerobioloav.net
Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10
Street address 5366 Flatrock Ct. fl Date Received: 06/30/10
City, State ZIP Monison, CO 80465 Date Analyzed: 07/07/10
Attn: Steve Shurtliff #200860-0 Date Reported: 07/07/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Buiiding Materials. EPA-600/R-93/116, July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additioaal Comments es/no La ers % area % area % com sition
98%
104456-9A White Tape N 4,10% Negative CELL 2
POSITIVE
104456-9B White Joint Compound N 4,10% 4% CHRY 96 C
DW03-01
POSITIVE
104456-9C White Texture w/ White Paint N 4,15% 3% CHRY 97 C
50%
104456-9D White/Tan Drywall N 4,65% Negative CELL 50
98%
104456-10A White Tape N 4,10% Negative CELL 2
POSITIVE
104456-1OB White Joint Compound N 4,10% 4% CHRY 96 C
DW03-02
POSITIVE
104456-1OC White Texture w/ White Paint N 4,15°/a 3% CHRY 97 C
70%
104456-1OD White/Tan Drywall N 4,65% Negative CELL 30
98%
104456-11A White Tape N 4,5% Negative CELL 2
DW03-03
POSITIVE
104456-11B White Joint Compound N 4,5% 3% CHRY 97 C
✓ �t �� `%' '�
�
i e c aum oe e
Laboratory Analyst
�`�,-/: �---�-.._..-______-. _
�
A� m Aumphreys
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysotile
CR = Crocidolite
TR = Tremolite
Trace=Less Than 1 %
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vermiculite
G = Gypsum
M = Mica
T=Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
��_HERUUIUIU(.�y LAUURATUIty
� IYJSIJ�W, W� �NliO��Rl1��
CONSUUING U80RATORY
Certificate of Analysis
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
303.232.�746
www.aerobioloav.net
Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10
Street address 5366 Flatrock Ct. fl Date Received: 06/30/10
City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10
Attn: Steve Shurtliff �200860-0 Date Reported: 07/07/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Homo- Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition
POSITIVE
104456-11C White Texture w/ White Paint N 4,10% 3% CHRY 97 C
DW03-03
50%
104456-11D White/Tan Drywall N 4,80% Negative CELL 50
104456-12A Gray Granular Plaster N 3,10% Negative 100 C
PLO1-01 104456-12B White Plaster N 3,30% Negative 100 C
104456-12C White Granular Plaster N 3,60% Negative 100 C
104456-13A Tan plaster w/ White Paint N 2,2% Negative 100 C
PLO 1-02
� 104456-13B Tan Granular Plaster N 2,98% Negative 100 C
104456-14A White Plaster w/ White Paint N 2,1% Negative 100 C
PLO 1-03
104456-14B White Granular Plaster N 2,99% Negative 100 C
FTO1-01 104456-15A Black Mastic N 2,2% Negative 100 B
f����,����,�
%
i e c aum oe e
Laboratory Analyst
% �� f:,�f� ��,.-----------_ _-
G- , �
r' ��,
--_ _
am Humphrey§
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysotile
CR = Crocidolite
TR = Tremolite
Trace=Less Than 1 %
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vermiculite
G = Gypsum
M = Mica
T = Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
��: AERUUIULUCjy LAUURATURy
-..�-•` ASSOCIATES, INCORPORATED
�` CANSULTING LABORATORY
Certifcate of Analysis
13949 W. Colfa�c Ave
Suite 205
Lakewood, CO 80401
303.2323746
www.aerobioloav.net
Client Name DS Consulting, Inc. _^����� Date Collected: 06/29/10
Street address 5366 Flatrock Ct. w � Date Received: 06/30/10
City, State ZIP Morrison, CO 80465 Date Analyzed: 07/07/10
Attn: Steve Shurtliff #200860-o Date Reported: 07/07/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: 104456
Job ID:
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Homa Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition
POSITIVE
FTOI-01 104456-15B Red Floor Tile N 2,98% 2% CHRY 98 B
f�.���i��--�'
�
i e c aum oe e
Laboratory Analyst
�''�,,,--�/„2---�-,.______..-- w.__._.__`_
�
AdamNumpTireys
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysotile
CR = Crocidolite
TR = Tremolite
Trace=Less Than 1 %
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vermiculite
G = Gypsum
M = Mica
T = Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
`�`HERUUIULUCjy LAUURATUR)/
--�„�-� ASSOCIATES, INCORPORATED
`` CANSUUING LA80RATORY
Certificate of Analysis
13949 W. Colfaz Ave
Suite 205
Lakewood, CO 80401
303.2323746
www.aerobioloqv.net
Client Name DS Consulting, Inc. ������ Date Collected: 06/29/10
Street address 5366 Flatrock Ct. fl Date Received: 06/30/10
City, State ZIP Morrison, CO 80465 Date Analyzed: 07/14/10
Attn: Steve Shurtliff #200860-0 Date Reported: 07/14/10
Client Project Name: 115 Forest Rd. Vail, CO Project ID: ]04456
Job ID: POINT COUNT
Test Requested: 3002, Asbestos in Bulk Samples
Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993.
Homa Number Asbestos Detected Non-Asbestos Non-Fibrous Matrix
Sam le Identification Physical Description of Sample; geneous of Fibers Material Material
Client Lab Sam le Number Additional Comments es/no La ers % area % area % com osition
POSITIVE
104456-SA White Compound w/ White Paint N 100% 2% CHRY
DWO1-OS
POSITIVE
104456-SC White Joint Compound N 100% 2.5% CHRY
POSITIVE
104456-8B White Joint Compound N 100% 1.5% CHRY
DW02-03 POSITIVE
104456-8C White Texture w/ White Paint N 100% 1.75% CHRY
POSITIVE
104456-1OB White Joint Compound N 100% 3.25% CHRY
DW03-02
POSITIVE
104456-1OC White Texture w/ White Paint N 100% 2.25% CHRY
/����i���� ��✓�/ %
J /
� e c aum oe e
Laboratory Analyst
/ /� .-�"`___----_.._...__. _
c�
Adam7-Iumplireys
Asbestos Laboratory Supervisor
A = Amosite
AC = Actinolite
AN = Anthophyllite
CHRY=Chrysotile
CR = Crocidolite
TR = Tremolite
Trace=Less Than 1 %
CELL = Cellulose
MW = Mineral Wool
FBG = Fiberglass
SYN = Synthetic
WO = Wollastonite
NTR = Non-Asbestiform TR
NAC = Non-Asbestiform AC
FT = Fibrous Talc
AH = Animal Hair
Q = Quartz
C = Carbonates
V = Vertniculite
G = Gypsum
M = Mica
T = Tar
P = Perlite
O = Organic
B = Binder
OP = Opaques
�AEROb10I.00.�y LAbORATOR}/
-`-` ASSOCIATES, INCORPORATED
`` CONSl1�nNG LABURATORY Certificate of Analysis
DS Consulting, Inc.
5366 Flatrock Ct.
Morrison, CO 80465
Steve Shurtliff
Client Project Name:
General Notes
115 Forest Rd. Vail, CO
♦ lYegative indicates no asbestos was detected; the method detection limit is 1%.
avdQ�.
N200860-0
♦ Trace or "<1" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1%.
13949 W. Colfax Ave
Suite 205
Lakewood, CO 80401
3032323746
www.aerobioloav.net
Date Collected: O6/29/10
Date Received: 06/30/10
Date Analyzed: 07/07/10
Date Reported: 07/07/10
Project ID: 104456
Job ID:
♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos
minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the
asbestiform variety of the mineral reibekite.
♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM.
Eor such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi-quantitative bulk TEM
floor tile analysis is accepted under the NESHAPS regulations.
♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation
of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted.
♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, [nc. will store the samples for a minimum period of thirty (30) days
before discarding. A shipping and handling charge will be assessed for the retum of any samples.
Notes Reauired bv NVLAP
♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
♦ This test repod relates only to the items tested or calibrated.
♦ This report is not valid unless it bears the name of a NVLAP-approved signatory.
♦ Any reproduction of this document must include the entire document in order for the report to be valid.
13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.2323746