Loading...
HomeMy WebLinkAboutB10-0216 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWWOFV& Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 i i p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 I r I ADD/ALT MF BUILD PERMIT Permit #: 1310-0216 Project #: PRJ10-0424 Job Address: 1500 MATTERHORN CR VAIL Status. . ISSUED Location......: UNIT 211 Applied. 08/03/2010 Parcel No....: 210312325015 Issued. .. : 09/01/2010 Expires . ..: 02/28/2011 f OWNER POINTES OF COLORADO 08/03/2010 EAGLE POINT RESORT ' 1500 MATTERHORN CIR VAIL t `.. CO 81657 APPLICANT LIFESTYLE KITCHEN&BATH CEN 08/03/2010 Phone:303-841-8899 10530 S. PARKER RD. UNIT A # PARKER COLORADO 80134 License:900-B CONTRACTOR LIFESTYLE KITCHEN&BATH CEN 08/03/2010 Phone: 303-841-8899 'x 10530 S. PARKER RD. UNIT A PARKER is COLORADO 80134 License:900-B Description: REMOVE TILE AND DRYWALL ABOVE BATHS, INSULATE, REINSTALL DUROCK,TILE F Occupancy: R1 Multi-Family Valuation: $3,060.00 I Type Constructlon:VB Total Sq Ft Added: 0 FEE SUMMARY **********************************************************t*****tt************* G Building Permit Fee----> $97.25 Will Cal Fee-----------------> $4.00 Total Calculated Fees-----------> $164.46 Plan Check-------------> $63.21 Use Tax Fee—-----—-----------> $0.00 Additional Fees-------------—--------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES-------> $164.46 Investigation------- ----> $0.00 Recreation Fee----------------> $0.00 Payments------------------------------> $164.46 Total Calculated Fees--------> $164.46 BALANCE DUE------------------------> $0.00 t ** DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 A i Signature of wner or Contractor Date e �Prr{t- Print Name bld_alt_construction _perm it_041908 f 3 APPROVALS Permit#: B10-0216 as of 09-01-2010 Status: ISSUED I I Item: 05100 BUILDING DEPARTMENT 08/31/2010 cg Action: AP f a See the Conditions section of this Document for any that may apply. I i f 7 [a E t }k f is P i S yy3 i f r, S f t i 1 bld_alt_construction _perm it_041908 RYWW!#iRY«Y!R««WW!#R«YYf#RRY##«RWYWiR«RWY4RRRWYl k!!WW#fRR#W!#««fWWYY4i#RWW##ifiR«RW!!i«R«WW##R«WW#ifRRW#WfRRWYf#«itWWY«RRRtYYl f«««WW4ifiRWWWYl fR«#«Y##««««YW##!R«#WYY!#Ri«iWWf!!!«««Y CONDITIONS OF APPROVAL 1 Permit#: B10-0216 as of 09-01-2010 Status: ISSUED !##«««WY!!R«tYR««i«W*«i«WWi«ikYWi#i««WWk#««YW#!R««WYW«««WYY«!««YY##««WWl R!!«WW#f«««RYW#««««WYY««««WWf«««WW**««WW!#«««WWYfi««WWff««««W!«#«*WWW#««Rii'k*i«iifY lilrfr«YYY!lIiYYYIYr#««WWf!!# 4 i Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.):ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. _ I i t ) ( I t bld_a It_construction_pe rm it_041908 i ******************************************************************************************** TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: R100001211 Amount: $164.46 09/01/201004 :15 PM Payment Method: Check Init: SAB Notation: 17903 - LIFESTYLE KITCHEN & BATH -------------- Permit No: B10-0216 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2103-123-2501-5 Site Address: 1500 MATTERHORN CR VAIL Location: UNIT 211 Total Fees: $164.46 This Payment: $164 .46 Total ALL Pmts: $164 .46 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 97.25 PF 00100003112300 PLAN CHECK FEES 63 .21 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ` ----------------------------------------------------------------------------- d s a r s S 3 4 i. c a. Department of Communi;tjr Dwelopment� 3 4} h 75 South Frantage_ Vail,x�n�ara . 9 -1 - e RI ill DING PERMIT APPLICATION Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: Office Use: �f _ 15 0 0 Matterhorn Circle Project#: t(./� U��1 2 r'1 - (Number) (Street) (Suite#) DRB#: Building/Complex Name: Eagle P O int Resort —v Building Permit#: Lot#: Block# Subdivision: Contractor Information, _ Company: Lifestyle Kitchen & Bath Ctr Company Address: 10530 S . Rarker Rd #A Detailed Smoe and Location of Work: Remo ve til e & dryw a 11 above bath tub. Per UL es U329 our Parker State: CO Zip: 80134 assembly. Insulate with 3 1/2`.' Thermafiber City. SAFB. n-I stal urock (1/2" on interior walls) contact Name: Timothy Tait (5/811 on artition/corrmon walls) , Install 1/4' pp,orce ain tie on walls & ceiling above tub Contact Phone: 303-841-8899/303-324-6970 change to existing tub. (use additional sheet if necessary) E-Mail tim @lifestylekit.chenandbath.com 9 0 OB Work Class: Town of Vail Contractor Registration No.: New( ) Addition( ) Remodel(X) Repair( ) Other( ) Work Type Con actor Signature(required) Interior(X ) Exterior( ) Both( j Property information Time e of Building' Parcel#: 210 3-123-25– 0 15 Single-Family ( ) Duplex( ) Multi-Family (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or Commercial( ) Other( ) visit www.eaglecounty.uslpatie) Tenant Name: Does a Fire Alarm Exist? Yes( X) No( ) Monitored Alarm? Owne Name: Points O f Colorado Yes( X) No ( r ) Does a Sprinkler System Exist? Yes( ) No (X ) #&Type of Existing Fireplaces: Gas Appliances Valuations(Labor& Materials) Gas Log_ WoodlPellet Wood Burning Building: $ 2050 . 0 0 #&Type of Proposed Fireplaces: Gas Appliances Plumbing: $ 560 , 00 Gas Log Wood/Pellet Wood Burning Electrical_ $ 45 0 0 0 Date Received: Mechanical: (including fireplace) $ Total $ 3060 . 00 n 7 Q �� J JUL 28 2010 TOWN OFVA!1_ All PIItE'- �RQNCY SERVG'�/ Vail Fire Department Asbestos Testing &Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regu- lations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing:_ One- and Two-Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units,and fractional fee units. - Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified and Vail-registered abate- ment contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) Tested positive at more than 1%, requires abatement (1 copies of test results included) Tips&Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of any age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA.Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: State of Colorado Contact: Fire Prevention Bureau Colorado Department of Public Health Vail Fire Department and Environment 75 S Frontage Rd Asbestos Compliance Assistance Group Fire_inspectors @vailgov.com 303-692-3158 970-479-2252 asbestos @state.co.us www.vailrjov.conn :vvvvv. .a)he.state.c:,u.,, 15-May-10 Y A & D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Design, and Consulting INTRODUCTION: On February 19th, 2010 an inspection/survey was conducted and 5 bulk samples were collected from: Eagle Point 1500 Matterhorn Circle Units: 201, 205, 207, 210, and 211 Vail, CO. 0 The purpose of the inspection/survey was to locate and sample suspected Asbestos containing materials that might be present in the above units that are planned for renovation. The inspection was made, and the samples were collected by John R. Peterman, an A.H.E.RA. and State of Colorado Certified Asbestos Inspector. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation for unseen conditions or stored items_ All samples were analyzed by DCM Science Lab in Wheatridge, CO. This laboratory is deemed "Proficient" in the E.P.A.Quality Assurance (QA) program for the determination of asbestos in bulk materials, and is accredited by the American Hygiene Association (AHA). SAMPLING PROTOCOL: A random sampling scheme was used to sample the suspect materials that were discovered. If during any future demolition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed, work should be halted until the material has been tested. 3 T .d e9-1. = T T 0 1 a T -+e W A & D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Design, and Consulting Eagle Point 1500 Matterhorn Circle Units: 201, 205, 207, 210, and 211 Vail, CO. UNIT DESCRIPTIONS: The Eagle Point is a multi-unit condo complex that is planned for selective renovation in several units. The units to be renovated are homogeneous in construction. Random units were selected from the designated units for testing purposes. The interior walls are covered in sheetrock with a heavy texture, and the ceilings in the renovation areas are covered in sheetrock like the walls, and spray-on acoustic texture. The floors are covered in carpet, and in ceramic tiles. This is the third set of testing that has been done at Eagle Point. The previous two reports are dated 6/29/07 and 8/21/09. I CONCLUSIONS & RECOMMENDATIONS: Laboratory analysis, of the composite sheetrock samples, indicates that Asbestos was detected in two out of the six bulk samples taken. However, the Asbestos content, of the positive samples, is less than the Regulatory Limit (Greater than I%Asbestos). The Asbestos content was verified by the required Point Count Analysis. i 4 z d eLt, = iT 0T aT JeW Date: February '19th, 2010 Location: Eagle Point, 1500 Matterhorn Circle, Units: 201, 205, 207, 210, and 211 in Vail, CO. SAMPLE LOCATIONS SAMPLE NUMBER AREA SAMPLE REMOVED FROM DESCRIPTION FRIABLE EP - B 023 Room 201 - Hallway Closet Wall Composite Sheetrock w/Texture NO EP - 13 024 Room 205 - Hallway Closet Wall Composite Sheetrock w/Texture NO EP - B 025 Room 211 - Living Room Closet Wall Composite Sheetrock w/Texture NO EP - B 026 Room 207 - Living Room Closet Wall Composite Sheetrock w/Texture NO EP - B 027 Room 210 - Living Room Closet Wall Composite Sheetrock w/Texture NO .v 0 N L N E Date: February 19th, 2010 Q Location: Eagle Point, 1500 Matterhorn Circle, Units: 201, 205, 207, 210, and 211 in Vail, CO. SAMPLE RESULTS: SAMPLE NUMBER DESCRIPTION ASBESTOS TYPE % EP - B 023 Composite Sheetrock vv/Texture NAD 0.00 EP - B 024 Composite Sheetrock vv/Texture NAD 0.00 EP - B 025 Composite Sheetrock vv/Texture CHRY PC <0.01 EP - B 026 Composite Sheetrock vv/Texture CHRY PC <0.01 EP - B 027 Composite Sheetrock vv/Texture NAD 0.00 KEY: �o r 0 L E NAD - No Asbestos Detected CHRY - Chrysotile PC - Point Count Analysis un Date: February 19th, 2010 Location: Eagle Point, 1500 Matterhorn Circle, Units: 201, 205, 207, 210, and 211 in Vail, CO. SUSPECT MATERIAL CONDITIONS SAMPLE NUMBER TYPE OF SUSPECT MATERIAL OVERALL CONDITION DAMAGED % TYPE OF DAMAGE EP - B 023 SUR GOOD NO 0.00 N/A EP - B 024 SUR GOOD NO 0.00 NIA EP - B 025 SUR GOOD NO 0.00 N/A EP - B 026 SUR GOOD NO 0.00 N/A EP - B 027 SUR GOOD NO 0.00 N/A KEY: 0 N L I0 E SUR -Surfacing co Date: February 19th, 2010 Location: Eagle Point, 1500 Matterhorn Circle, Units: 201, 205, 207, 210, and 211 in Vail, CO. POTENTIAL FOR DISTURBANCE Sample Number Accessibility Potential Influence Potential Located in Plenum yes/no contact vibration air erosion yes/no EP - B 023 YES HIGH LOW LOW NO EP - 13 024 YES HIGH LOW LOW NO EP - B 025 YES HIGH LOW LOW NO EP - B 026 YES HIGH LOW LOW NO EP - B 027 YES HIGH LOW LOW NO M co 0 N L M E 3 N r 0 r .A m Iv 73 BULK ASBESTOS TEST REPORT PAGElOF3 ANALYSIS DATE: 2-25.10 IENT: A&D ASBESTOS TESTING AND CONSULTING REPORTING DATE: 2-25-10 P.O.BOX 1230 RECEIPT DATE: 2-22-10 CLIFTON,CO 81520.1230 CLIENT JOB NO.: EAGLE POINT CONDO PROJECT TITLE; 1500 MATTERHORN-VAIL,CO DCMSL PROJECT: ADAT563 PERCENTAGE!COMPOSITION BY VISUAL.ESTIMATE TOTAL TOTAL PERCENTAGE 'MSL CLIENT SAMPLE. PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED MPLE IMBER SAMPLE NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS ND 0.0 100.0 100.0 EP-B-023 2.19-10 A. PINK PAINT 1'�0 ND 0.0 100,0 100.0 -4 B. WHITE DRYWALL MUD 3.0% 100.0 0.0 100.0 C, TAN AND GREEN FIBROUS 15.091 ND 1.0 99.0 100.0 D. WHITE DRYWALL 8110% ND ND ND 0.0 100.0 100.0 5 EP-B-024 2-19.10 A. WHITE PAINT 2.0% ND 0.0 100.0 100.0 B. WHITE DRYWALL MUD 3 0% 100.0 0.0 100.0 C. TAN FIBROUS 10.0% ND ND 1,.0 99.0 10010 D. WHITE DRYWALL 85.0% ND 2 A. PINK DRYWALL MUD 0.5% CHRYSOTILE (TR-1] 0.5 0.0 0.0 99.5 10010 1000 100.0 -6 EP-B-025 -19.10 B. WHITE PAINT 2'�0 ND 0.0 140,0 100.0 C. WHITE DRYWALL MUD 7.0% ND 100.0 100.0 4.0 100'0 D.TAN FIBROUS 12.0% ND ND I.0 99.0 I- PINK DRYWALL 78.50A <0.l 3 N r 0 r .A m Iv 73 3 Ol r N r O r r m Ili m 12421 W.49TH AVENUE,UNIT#6 WHEAT RIDGE,CO 80033 (303)463.8270 BULK ASBESTOS TEST REPORT PAGE 2 OF 3 LIENT: ANALYSIS DATE: 2-25-10 A&D ASBESTOS TESTING AND CONSULTING REPORTING DATE: 2.25-10 P.O.BOX 1230 RECEIPT DATE: 2-22-10 CLIFTON,CO 81520-1230 CLIENT JOB NO.: EAGLE POINT CONDO PROJECT TITLE: 1500 MATTERHORN -VAIL,CO DCMSL PROJECT: ADAT563 PERCENTAGE COMPOSITION BY VISUAL ESTIMATE TOTAL TOTAL PERCENTAGE CMSL CLIENT AMPLE SAMPLE SAMPLE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED UMBER NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS -7 EP-8-026 2-19.10 A. PINK DRYWALL MUD 0.5% CHRYSOTILE [TR-11 0.5 0.0 99.5 100.0 B. WHITE PAINT 1.0% ND 0.0 100.0 100.0 C. WHITE DRYWALL MUD 5.0% ND 0.0 100.0 100.0 D. TAN FIBROUS 12.0% ND 100.0 0.0 100.0 E. PINK DRYWALL 81.5% ND 1.0 99.0 100.0 <0.I -8 EP-B-027 2-19.10 A. WHITE PAINT 2.0% ND 010 10010 100.0 B. WHITE DRYWALL MUD 7.0% ND 0.0 100.0 100.0 C. TAN FIBROUS 10.0% ND 100.0 0.0 100.0 D. WHITE DRYWALL 81.0% ND 1.0 99.0 100.0 ND OR CALCULATION PURPOSES,TRACE (TR)IS ASSUMED TO BE 0.5%. )-INSEPARABLE LAYERS ND-NONE DETECTED 3 Ol r N r O r r m Ili m ' III DCM SCIENCE LABORATORY,INC. 12421 W.49TH AVENUE,UNIT#t6 WHEAT RIDGE,CO 80033 (303)463-8270 BULK ASBESTOS ANALYSIS-POINT COUNT METHOD PAGE 1 OF 2 CLIENT: ANALYSIS DATE: 3-2-10 A&D ASBESTOS TESTING AND CONSULTING REPORTING DATE: 3-2-10 P.O.BOX 1230 REQUESTED DATE: 2-25-10 CLIFTON,CO 81520-1230 CLIENT JOB NO.: EAGLE POINT CONDO PROJECT TITLE: 1500 MATTERHORN-VAIL DCMSL PROJECT: ADAT565 CROSS REFERENCE: ADAT563 PERCENTAGE COMPOSITION BY AREANOLUME DCM LAB NO.: -1 -2 SAMPLE DATE: 2-19-10 2-19-10 %OF TOTAL SAMPLE: 0.5% 0.5% CLIENT NO.: EP-B-025 EP-B-026 PART A PART A ASBESTIFORM MINERAL FIBERS: CHRYSOTILE 0.25% 0.25% AMOSITE ND ND CROCIDOLITE ND ND TREMOLITE-ACTINOLITE ND ND ANTHOPHYLLITE ND ND TOTAL ASBESTOS COUNTED 0.25% 0.25% TOTAL ASBESTOS IN LAYER 0.25% 0.25% TOTAL ASBESTOS IN SAMPLE <0.01% <0.01% NOTES: SAMPLES NO. 1 AND 2 ARE PINK DRYWALL.MUD_ ND-NONE DETECTED DEFINITIONS TOTAL ASBESTOS COUNTED = THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN LAYER = THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN SAMPLE = THE PERCENT OF TOTAL SAMPLE(FROM PLM/SM ANALYSIS) TIMES THE TOTAL ASBESTOS IN LAYER(IF NO ASBESTOS IN OTHER LAYERS). 6 'd eBb = TT OT Zi JeW I i I i Closet CO CO I Bedroom i W General Scope of Building Permit Remove tile & drywall above exiting bath tub Per UL Des U329 I hour assembly Insulate with 3 1/2" Thermafiber SAFB Install Durock (I/2" on interior walls) (5/8" on partition/common areas) X Existing Install 1/4" porcelain the on walls & Bath Fan ceiling above tub No Changes No change to existing tub & tub/shower faucet Bath — .IXVV2436 IXW.3321 IXW 1 36 IXW302124 � 05" in 24.gW Spac IBER24L IXk315WASTEA W ) 0:/ Kitchen it 60R-BATH-1 BF3 , O .. .. -- --... . ..................... ..... ....°-.......... O' IXB 6 -" IXW3021 k. M Closet ,t 1051, Eating Nook Y11 + CR I Eagle Point j Std 1 Bedroom 599 Sq Ft 3/8" Scale Overall Scope in addition to above Remove & install new kitchen & bath cabinets, countertops, sinks, faucets in same location Remove & install tile on floor of kitchen I baths, 44 entry Install wall tile above new kitchen $-� countertops to underside of wall cabs 10 i Living Room Install undercabinet light over kitchen sink on separate switch I Install new circuit for microwave 00 I Install new electric devices in kitchen & bath N Install GFCI outlets in kitchen & bath o o Remove smoke detector in kitchen/living area Install heat sensor during construction Re-install smoke detector upon completion --— – 179" 11 28" 0 207",,n i 0 I C All dimensions _size designations given are n ^s This is an original design and must not be Designed:7/9/2007­Y g 2 20;F�� released or copied unless a licable fee• has Yrintcd: 7 1 U/-1007 �l .,. (subject to verification on job site and TECHNOIOGIes P applicable, �-_.- 1- 1ridjustmenr to fit job conditions. been paid or job order placed. 1 i 0�&E 10 -oq Z-,-( 11-15-2010 Inspection Request Reporting Page 27 5:04 pm Vail, CO - City Of Requested Inspect Date: Tuesday, November 16, 2010 Inspection Area: CG Site Address: 1500 MATTERHORN CR VAIL UNIT 211 A/P/D Information Activity: B10-0216 Type: A-MF Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: VB Insp Area: CG Owner: POINTES OF COLORADO Contractor: LIFESTYLE KITCHEN & BATH CENTER Phone: 303-841-8899 Description: REMOVE TILE AND DRYWALL ABOVE BATHS, INSULATE, REINSTALL DUROCK,TILE Requested Inspection(s) Item: 90 BLDG-Final Requested Time: 09:30 AM Requestor: LIFESTYLE KITCHEN & BATH CENTER Phone: 303-841-8899 -or- 303-324- Comments: 303.880.9428 6970 TIM Assigned To: JMONDRAGON Entered By: CGUNION K Action: Time Exp: Pl. Inspection History ` Item: 30 BLDG-Framing **Approved** 1 09/20/10 Inspector: MDENNEY Action: AP APPROVED Comment: Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail **Approved** 09/30/10 Inspector: Martin Action: AP APPROVED Comment: Item: 70 BLDG-Misc. Item: 90 BLDG-Final REPT131 Run Id: 12186