HomeMy WebLinkAboutM10-0149NO TE: THIS PERMIT MUS T BE POS TED ON JOBSI TE A T
WOF M
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149
MECHANICAL PERMIT
ADUP
Job Address: 1475 LIONS RIDGE LP VAIL
Location.....: 1475 LIONS RIDGE LOOP (W)
Parcel No...: 210312202028
OWNER STALCY, TRENTON J. 08/04/2010
8395 PONDEROSA DR
PARKER
CO 80138
APPLICANT WESTERN FIREPLACE SUPPLY, IN 08/04/2010 Phone: 668 -3760
1685 PAONIA
COLO SPRINGS, CO 80915
PO BOX 670
MINTURN, CO 81645
License: 323 -M
CONTRACTOR WESTERN FIREPLACE SUPPLY, IN 08/04/2010 Phone: 668 -3760
1685 PAONIA
COLO SPRINGS, CO 80915
PO BOX 670
MINTURN, CO 81645
License: 323 -M
Desciption: INSTALL GA LOG SET IN EXISTING ZERO CLEARANCE FIREPLACE USE
EXISITING GAS LINE
Valuation: $2,625.00
ALL TIMES
Permit #: M10 -0149
Project #: PRJ10 -0427
Status ...:
ISSUED
Applied ..:
08/04/2010
Issued . .:
08/05/2010
Expires. .:
02/01/2011
Mechanical Permit Fee - -> $60.00 Will Call ------------ > $4.00 Total Calculated Fees --- > $79.00
Plan Check------------ - - - - -> $15.00 Use Tax Fee ------ > $0.00 Additional Fees --- — ------ > $0.00
Investigation — --------------- > $0.00 TOTAL PERMIT FEE --- > $79.00
Total Calculated Fees - -> $79.00 Payments -- ------- > $79.00
BALANCE DUE-- - - - - -> $0.00
Item: 05100 BUILDING DEPARTMENT
08/04/2010 JRM Action: AP
APPROVALS
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 42
(BLDG 2009) CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSP SHALL BE MADE IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(
AM -4 PM.
8 S /c7
e of Owner or Contractor Date
mechcanica I_pe rm it_041908
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO
Statement
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number:
R100000978 Amount: $79.00 08/05/201009:33 AM
Payment Method:
Check Init: LC
Notation:
#2631 /
WESTERN FIREPLACE SUPLLY INC
-----------------------------------------------------------------------------
Permit No:
M10 -0149 Type: MECHANICAL PERMIT
Parcel No:
2103 - 122 - 0202 -8
Site Address:
1475 LIONS RIDGE LP VAIL
Location:
1475 LIONS RIDGE LOOP (W)
Total Fees:
$79.00
This Payment:
$79.00 Total ALL Pmts:
$79.00
Balance:
$0.00
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code
Description Current Pmts
-------------- - - -
MP 00100003111100
- -- ------------------------ - - - - -- ------
MECHANICAL PERMIT FEES
- - - - --
60.00
PF 00100003112300
PLAN CHECK FEES
15.00
WC 00100003112800
WILL CALL INSPECTION FEE
4.00
08/02/2010 08:27 FAX' 9708279222 ",YE"'TEPN FIPEF1J.!'E 2001/003
❑ Complete Mechanical Room Floor Plan with Dimensions
o Combustion Air Duct Size and Location
❑ Flue detail or Vent size, location & torm(nifflon
o Gas Piping layout including development length calculations
Q Meet Low Calculations
............
Project Street Address
147 �0tl5 F4 t>4F- Zwr
(Number) (Street) (suite 0)
a Boller size & efficlency
u Equipment Cut Sheets for Ffreplaces/Log Sets
(Manufacturer's info shoWna nuke, model & aODP
Office Use:
Building Permit t
I m , o1 #7;5
Mechanical Permit 9: -- rr
Lot A. — Block # — Subdivision:
i Bulldlng/Complax Name:
i Contractor information;
i Company; W6WFLRAi_EtLF.Ft,4W– 6J??LY
Company Address: To Slog 4 23
Clty: Asl 0`AJ state: CAC) zip: ( 2
Contact Name: &F- 14 6 FITS
Contact Phone: 624 — 14 2- 1
'Town of Vail Cont tratlon No.: :5 M
7:>
Cent . h I VqUIMU)
Property Infonnatlon
Parcel 0: 122-0 2. -0 ZS
(For parcel X, oor►tect Eagle County Assessors Offlos at 970-326-6040 of
visit www.saglecounty.us/potle)
Name; (Commercial Pro artioa)
Owner Name:
Complete Valuation for Mechanical Permit: (inoluding fireplaces)
C*
Mechanical $:
DofineSoopa and Location of Work: JAt&T1*44. 4 A
LOCc fa C I At rO 116 T, A*4 9:Z
KODF-L
(um edftonal shm if necesvery)
o Gas Piping included
❑ Gas Plolng by Others
❑ Wood to Gas Fireplace Conversion
J
Boller Location:
interior , Exterior Other
Number of Existing Fireplaoss!
Gas Appliances I G*31 Wood/Pellet
Number Of PPOP680d Firaplacow
Gas Appliances — GaS LOGS I Wood/Pallet
Type of Building;
single-Family Duplex Multi-Family ComrneMlQl
Restaurant Other
Date Received;
E E
AUG 0 2 2010
C:'4dv\forms\permitskbuEdbigVrmhanicaLjcrjWLOIOIIC
- TOWN OF VAIL
MECHANICAL PERMIT
08102/2010 08:28 FAX 9708279222 WE;a7ERN FIREPLPCE 2002,'003
0 Installation
HEARTH & HOM E Instructions
technologles
.Models-
REMISING, REM18LP, REI�,24NG3, REM24LP,
REM30NG, REM30LP, SH tIONG, SHKISLP,
SHK24NG, 8HK24LP, SHK30NG, SHK30LR
STREMI8NG, STREMI8LP, STREM24NG,
STREM24LP, STSHKI8NG,#,STSHK1SLP,
STSHK24NG, STSHK24LP
Fireside Burner /Hearth Kits
Check with your local building code agency before you begin installation to answe compliance with local codes. including
the need for permits and follow -up inspections. If you encounter any problems regarding code approvals, or if you need
clarification of any of the instructions contained here, contact the Technical Services Dept.. Hearth 8 Home Technologies
Inc., phone 1 -888 -427 -3973 or 1-800 -e27 -6841.
CAUTION
DO NOT DISCARD THIS MANUAL 440 14"
• Important operating • Read, understand - Leave this manual with +
and maintenance and follow these party responsible for 0 0
Instructions included. instructions for safe use and operation.
Installation and
® WARNING
If the intornmitlon In these iaa#ruc-
tlons Is not followed exactly, a
fire may result causing property
--•- -- damage, personal Injury, or death.
• Do not store or use g4sollne or other flam-
mable vapors and liquids in the vicinity of
this or any other appliaince.
• What to do If you small gas;
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency. or
the gas supplier.
I ,k, A WARNING
Installation and service of this
appliance should be performed by
qualified personnel. Hearth & Home
Technologies suggests NFI certified
or factory- trained professionals, or
c technicians super-
•. vised by an NFI
certified profes �•••
slonal.
KOTt DO NOT TOUCH
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children In same room as
appliance.
• Alert children and adults to hazards of high
"Veratures,
• Keep clothing, furniture, draperies and other
combustibles away.
In the Commonwealth of Massachusetts:
Note: An arrow (0) found in the text signifies change in
This appliance must be installed by a licensed plumber
or gag fitter:
The chimney flue damper, when used with gas logs, will
be wetded open or compifiy removed.
A CO detector shall be Installed In the room where the
a Is Installed.
content.
Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004 -303 Rev A • 05/05
02;02!2010 08:22 FAX 97082J9222 WEJERN FIB. P! ACE
[)003/003
Listing and Code Approvals
A. Appliance Certification
The Fireside Sumer /Hearth Kits have been tested and listed
in the U.S. In accordance with ANSI Z21.80b -2004 (Gas Lop
Set). In Canada the Gas Log Hearth Kits have been tested
and approved in accordance +with CGA 2.26b,2004. They
have been listed by OMNI lost Labs for Installation and
operation In the United States and Canada sus described in
these Installation and Operating Instructions. All components
are UL, OMNI, or CSA safety certified.
■
Check with your local building code agency prior to installing
this appliance to ensure compliance with local codes,
Including the need for permits and follow -up inspections.
In the absence of local codes, comply with the National
Fuel Gas Code, ANSI Z223.1-1_atost Edition In the U.S.;
In Canada, the CAN/CGA 8149 Installation Codes. If any
assistance is required during installation, please contact
your local dealer or call the 'rechnical Services Department
at 1- 888 -427 -3973 or 1.804- 927 -8841.
WARNING
Improper Installation, adjustment, alteration, service
or maintenance can cause Injury or property damage.
Refer to the owner's Information manual provided with
this appliance. For assistance or additional information
consult a qualified installer, service agency or the gas
A WARNING
Fire Risk
Exhaust Fumes Risk
Do NOT uae this appliance as a vent free
heater.
The flue must be permanently open. Refer
to Table 1.
B. Table 1
08 -18 -2010 Inspection Request Re orting Page 32
4:13 pm Vail, Co - City OF
Requested Inspect Date: Thursday, August 19, 2010
Assigned To: CGUNION
Inspection Type: MECH
Site Address: 1475 LIONS RIDGE LP VAIL
1475 LIONS RIDGE LOOP (W)
A/P /D Information
Activity: M10 -0149 Type: B -MECH
Sub Type: ADUP
Status: ISSUED
Const Type: Occupancy:
Use:
Insp Area:
Owner: STALCY, TRENTON J.
330 MECH - Supply Air
Item:
Contractor: WESTERN FIREPLACE SUPPLY, INC.
Phone: 668 -3760
390 MECH -Final
Description: INSTALL GA LOG SET IN EXISTING ZERO CLEARANCE FIREPLACE USE EXISITING GAS LINE
Item: 390 MECH -Final
Requested Time:
10:30 AM
Requestor: WESTERN FIREPLACE SUPPLY, INC.
Phone:
668 -3760 -or- (970) 827 -
9623
Comments: 445 -7173
Assigned To: CGUNION
Entered By:
JMONDRAGON K
Action: Time Exp:
Inspec History
Item:
Item:
200 MECH -Rough
310 MECH - Heating
Item:
Item:
315 PLMB -Gas Pipin�gg
320 MECH - Exhaust Noods
Item:
330 MECH - Supply Air
Item:
340 MECH -Misc.
Item:
390 MECH -Final
, 1 A . 1jd
REPT131 Run Id: 11835