HomeMy WebLinkAboutB10-0189 comment letterDepartment of Community Development
5 South Frontage Road
Vail, Colorado 81657
970-479-2138
FAX 970-479-2452
www.vailgov.com
______________________________________________________________________
PROJECT REVIEW COMMENTS
DATE: 8/13/10
TO: sparks@vailplazahotel.com
toddg@gouldingadvisors.com
PERMIT APPLICATION #: B10-0189
PROJECT ADDRESS: 16 Vail Road
OCCUPANCY GROUP: mixed
TYPE OF CONSTRUCTION: IB
NUMBER OF STORIES: existing
BUILDING AREA: addition
● Submit three complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified.
● Please respond in writing to each comment with a response letter addressing each comment.
BUILDING DEPARTMENT COMMENTS
Rear vestibule addition
1 Revise plans to include complete construction details for 1 hour fire resistive columns, beams and roof assembly. Include UL or other fire resistive listing detail. The UL F906 referenced
does not appear to be applicable. IBC table 601
2 Include wall, and roof sections showing insulation R-values at exterior walls and roof per 2009 IECC
3 Show class A roof covering per Town of Vail ordinance at new
4 Complete the attached Town of Vail special inspection packet for structural steel and welding inspection.
5 Include connection detail for HSS columns to new foundation and HSS column to beams