Loading...
HomeMy WebLinkAboutD10-0004TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES DEMO. OF PART /ALL BLDG Job Address: 996 PTARMIGAN RD VAIL Location.......: Parcel No....: 210108115003 OWNER OML INVESTMENTS INC 08/04/2010 975 AMERICAN PACIFIC DR STE 104 HENDERSON 08/16/2010 NV 89014 02/12/2011 APPLICANT BECK BUILDING COMPANY 08/04/2010 P.O. BOX 4030 $816.21 VAIL $4.00 CO 81658 $816.21 License: 117 -A CONTRACTOR BECK BUILDING COMPANY 08/04/2010 P.O. BOX 4030 VAIL CO 81658 License: 117 -A Desciption: DEMO STRUCTURE Occupancy: R3 Single Family Residence Type Construction: VA Permit # D10 -0004 Project # ?? R aTL d —ol t Z Status ...: ISSUED Applied ...: 08/04/2010 Issued ...: 08/16/2010 Expires.....: 02/12/2011 Phone: 970 - 949 -1800 Phone: 970 - 949 -1800 Valuation: $35,000.00 Revision Valuation: ?? Total Sq Ft Added: 0 FEE SUMMARY Building ---- -> $492.25 Restuarant Plan Review —> $0.00 Total Calculated Fees —> $816.21 Plan Check --- > $319.96 Recreation Fee-- - - - - -> $0.00 Additional Fees ------ > $0.00 Investigation -> $0.00 TOTAL FEES-- - - - - -> $816.21 Total Permit Fee ------ > $816.21 Will Call —> $4.00 Payments - - - - -- $816.21 BALANCE DUE- - - - - -> $0.00 ++ *+*+ s*+ s###***++ sssf#*##++ s+# f###* ffs+ s*#*#* s* s*#+#**#+*+*+ f+***+*+*+ f+*#*#+* s+ s++##### fs++*##*##* s++ s+*##* s* s+ s +s # * * + * * * +ss + + * * + * # fss +s + + # # # *s Approvals: Item: 05100 BUILDING DEPARTMENT 08/16/2010 JRM Action: AP Item: 05400 PLANNING DEPARTMENT 08/11/2010 bgibson Action: AP see conditions. plans routed to JRM. Item: 05600 FIRE DEPARTMENT 08/11/2010 McGee Action: CR Provide asbestos clearence letter or submit for asbestos abatement permit. 08/16/2010 drhoades Action: AP Asbestos Inspection report received. Negative for ACM. Item: 05500 PUBLIC WORKS 08/12/2010 is Action: AP See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 479 -2149 OR AT OUR OFFICE FROM 00 AM 4 PM. / Glc. L O /�� C .o SIdN49TUn OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ************************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CONDITIONS OF APPROVAL Permit #: D10 -0004 as of 08 -16 -2010 Status: ISSUED ************************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Type: DEMO. OF PART /ALL BLDG. Applicant: BECK BUILDING COMPANY 08/16/2010 970 - 949 -1800 Job Address: 996 PTARMIGAN RD VAIL Location: Parcel No: 210108115003 Description: DEMO STRUCTURE Applied: 08/04/2010 Issued: To Expire: 02/12/2011 Cond: 38 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479 -2252. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0011562 The applicant shall re -grade and re- vegetate the site to a natural state within 14 days of completing demolition if a building permit for the proposed new residence has not been obtained and construction is being diligently pursued. ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 08 -16 -2010 at 11:04:10 08/16/2010 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R100001078 Amount: $816.21 08/16/201011:03 AM Payment Method: Check Init: JRM Notation: ----------------------------------------------------------------------------- Permit No: D10 -0004 Type: DEMO. OF PART /ALL BLDG. Parcel No: 2101 - 081 - 1500 -3 Site Address: 996 PTARMIGAN RD VAIL Location: Total Fees: $816.21 This Payment: $816.21 Total ALL Pmts: $816.21 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 492.25 PF 00100003112300 PLAN CHECK FEES 319.96 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 I 0 Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: Office Use: P 99 41 f'7 *A_'0I f /� 1 49,¢4 Project #: � /� + �� L (Number) (Street) (Suite #) DRB #: Building /Complex Name: AA Building Permit #: l u -- 64 b Contractor Information: Company: Ace!. 4041016 . Go. Company Address: P19 BoX 4�ov?O City: 0—/ L, State: GG Zip: 4!5V445 Contact Name: &; /LOG.' Nti &W Contact Phone: '7 7 O 1 7 - 7 — is G 7 E -Mail 60 b a hdw -GjC k"- ld t • GOw� To f Vail Con actor Registration No.: 117 X Contra for Signature (required) Lot #: Block # Subdivision: Detailed Scope and Location of Work: AIP (use additional sheet if necessary) Work Class: New ( ) Addition ( ) Remodel ( ) Repair ( ) Other (� Work Type Interior( ) Exterior( ) Both( Property Information Type of Building: Parcel #: Z/ o / Single-Family Duplex( ) Multi-Family( ) (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or l ia visit www.eaglecounty.us /patie) Commercial( ) Other( ) Tenant Name: Does a Fire Alarm Exist? Yes ( ) No( ) Owner Name: 1�/} -!J VA _t lam, L t,G . Monitored Alarm? Yes ( ) No( ) Does a Sprinkler System Exist? Yes ( ) No( ) Valuations (Labor & Materials) Building: Plumbing: Electrical: Mechanical: (including fireplace) Total: $ O�S Opp $ / 'V42' $ /NYC. $ 1AJ C $ 36 # & Type of Existing Fireplaces: Gas Appliances [ Gas Log Wood /Pellet Wood Burning I # & Type of Proposed Fireplaces: Gas Appliances Gas Log Wood /Pellet Wood Burning _ _ ..... _ _ ..... __..._...._ __ ......... ............. Date Received: 15- May -10 BUILDING PERMIT APPLICATION DSConsulti ng, Inc. Asbestos Inspection and Sampling Report 996 Ptarmigan W Vail, Cblorado 81657 J)ID-000y Presented to: Mr. Bob Brownlee Beds Building Company PO Box 4030 Vail, 00 81658 Performed & Prepared by.• Mr. Steve Shurtliff DSConsulting, Inc. PO Box 6864 Avon, 00 81620 (303) 378 -1544 Project Details DSC Project #: 2473 Conducted: July 14, 2010 EXECUTI VE SUMMARY On Jily 14, 2010, Mr. Steve Shurtliff of DSConsulting, Inc. (DSC) performed a full building inspection and collected asbestos bulk - samples at 996 Ptarmigan Rd, Vail, Colorado, in order to identify potentially hazardous friable and non - friable asbestos- containing materials (ACM) within the above - referenced, single family residence that is scheduled for demolition. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos-containing material (AQW) as a material containing more than 1 % asbestos. Mr. Shurtliff performed asbestos bulk - sampling of drywall (surfacing material) in a total of seven (7) locations throughout the residence and garage, stucco (surfacing material) in a total of five (5) locations on the exterior of the residence aswell as insulation (miscellaneous material) in a total of one (1) location within the crawlspaoe. All thirteen (13) bulk - samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP #200860 -0) in Denver, Colorado with all thirteen (13) laboratory results reporting as negative for asbestos ( see Appendix 8 for laboratory resul ts) . 2 IZ:Z•ii • :� a I. Introduction Afull building inspection and bulk - sampling for ACM was conducted at 996 Ptarmigan Rd, Vail, Colorado, by Mr. 9iurtliff on dily 14, 2010 at the request of Mr. Bob Brownlee with Beds Building Company. Mr. Shurtliff isa Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix A for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non - friable ACM within the interior of the residence and garage aswell asthe exterior. II. Structural Design The structure isa wood - framed, two-level, single - family residencewith attached garage. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk - sampling techniques. The asbestos bulk - sampling was conducted on suspect ACM with a limited number of bulk - samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency / AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk - samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title I I of the Toxic Substances Control Act (TSCA),15 USG Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un- sampled material. Bulk - samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600 / R( 116, .Lly, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk - samples was performed on the "date reported," as listed in the bulk - sample analysis report. 3 IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. S.rrfacingMaterial: sprayed or troweled onto structural building member. 2. Thermal system Insulation (T9): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl/ linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). • One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response- action recommendations for asbestos - containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1 % within the bulk - sample, or a bulk - sample in the same HA, and should be addressed accordingly. Ageneral recommendation indicates asbestos does not exist greater than 1% within the bulk - sample, or a bulk - sample in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1 % unless it i s analyzed by t he point-count method to be l ess t han 1%. V. Inspector Comments No asbestos - containing material (ACM) was identified during the bulk - sampling conducted at 996 Ptarmigan Rd, Vail, Colorado. Atotal of thirteen (13) bulk - samples were collected from drywall, stucco and insulation. All thirteen (13) bulk - samples tested negativefor asbestos. 4 VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent- asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 996 Ptarmigan Rd, Vail, Colorado on Ily 14, 2010. The quantities are approximations and are subject to field verification: Homogeneous Area #0 1 Homogeneous Area #0 1 temple #: DW01 -01 Simple #: DW01 -02 ,%mple Description: Drywal I %mple Description: Drywall Sample Location: Garage Wal I - NW Corner %mple Location: Ground Level - NW Room - NE Material Cjantity. >5,OOOft Corner Material Oassification: Surfacing Material Material Oasgfication: Surfacing Material Material Oiantity >5,OOOft Material Qiantity.� >5,OOOft Material Condition: GxA Material Condition: Good Physical Description (layers): White joint Plhysrca/ Description (layers): Yellow fibrous compound; White tape; White compound w/ white woven; White compound w/ white paint p aint; White/ tan drywal l Asbestos Detected (layers): Negative; Negative; Asbestos Detected (layers): Negative; Negative N tive; N egative fecornmendations GENERAL -See Section VI I Fboommendations GENERAL See Section VI I Homogeneous Area #01 Semple #: DW01 -03 Homogeneous Area #0 1 Simple #: DW01 -04 SampleDescription: Drywall %mple Description: Drywall Samp/eLocaticn: Ground Level - Hallway Bathroom - NE Corner Sample Location: Ground Level - Beneath Steirsto Upper Level - NE Corner Material Oassification: Surfacing Material Material Oas4f!cation: Surfacing Material Material Cjantity. >5,OOOft Material Qjantity. >5,OOOft Material Condition: Good Material Condition: Cbod Physycal Description (layers): Yellow fibrous woven; White tape; White texture; White/ tan drywall Physical Description (layers): White tape; White joint compound; Whitetexture; Whiteltan drywall Asbestos Detected (layers): Negative; Negative; Negative; Negative Asbestos Detected (layers): Negative; Negative; Negative; Negative Fiscommendations C -See Section VI I Fbcommendations GENERAL - See Section VI I H omogeneous Area 1 S%mple #: DW01 -05 Homogeneo Area #01 Simple #: DW01 -06 ,%mpleDescription: Drywall �%mpleDescription: Drywall Sample Location: Upper Level -Master Bedroom - SW Corner Sample Location: Upper Level - Kitchen - NE Corner Material Classification: Surfacing Material Material Classification: Surfaci ng Material Material Qjantity. >5,00oft Material Qjantity. >5,000ft Material Condition: Good Material Condition: Good Physical Description (layers): Yellow fibrous woven; White tape; White texture Physical Description (layers): White tape; White compound; White texture; White/ tan drywall Asbestos Detected (layers): Negative; Negative; Negative - joint Asbestos Detected (layers): Negative; Negative; Negative; Negative lgcommendations GE NERAL -See Section VI I Rq=nmendations GENERAL - See Section VI I Homogeneous Area #0 1 temple #: DW01 -07 Homogeneous Area #02 Sample #: PL01 -01 Sample Description: Drywall %mpleDescription: Exterior Stucco ,%mple Location: Upper Level - Di ni ng Room - NW Corner %mple Location: North Wal I Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity >5,00oft Material Cjantity. >1,000ft but <5,00oft Material Condition: Good Material Condition: Cbod Physical Description (layers): Yellow fibrous woven; Whitetape; White texture w/ white paint; White'oint compound; White/ tan drywall Phys+cal Description (layers): Cray plaster; White granular plaster Asbestos Detected (layers): Negative; Negative; Negative; N ive; Negative Asbestos Detected (layers): Negative; Negative Rq=nmendations GENERAL - See Section VII fbcommendations GE NE RAL - See Section VI I H omogeneous Area 1 S %mple #: PL01 -02 • ••- -• 1 Simple #: PL01 -03 S %mpleDsscription: Exterior Stu000 %mpleDescription: Exterior Stu000 ,ample Location: West Wall I Simple Location: West Wall I Material Cassification: Surfacing Material Material aassification: Surfacing Material Material GLantity >1,000ft but <5,00oft Material Qjantity.* >1,000ft but <5,00oft Material Qmdition: Good Material Condition: Good Physical Description (layers): White foam; Cray taster; White granular plaster Plhyscal Des ription (layers): White granular plaster; Gray plaster Asbestos Detected (layers): Negative; Negative; Negative �� la e (y o Negative; Negative Pecommendations GE NERAL - See Section VI I Pecommeadations GENERAL - See Section VI I H omogeneous Area 1 S%mp/e #: PL01 -04 • ••- -• 1 Sample #: PL01 -05 ,amp/eDescription: Exterior Stucoo %mpleDescription: Exterior Stu000 SbmpleLocation: South Wall ,%mpleLocation: East Wall Material Classification: Surfacing Material Material C1ass±tication: Surfacing Material Material Qjantity. >1,000ft but <5,00oft Material Qjantity. >1,000ft but <5,00oft Material Condition: Good Material Condition: Good Physfca/ Description (layers): Gray plaster; White g ranular plaster Physical Description (layers): White granular plaster; Gray plaster Asbestos Detected (layers): Negative; Negative Asbestos Detected (layers): Negative; Negative Pecommeadations GENERAL - See Section VI I Flq=nmeidations GENERAL - See Section VI I Homogeneous Sbmple #: I NS01 -01 ,%mple Description: Insulation SbmpleLocation: Crawlspace Material Classification: Miscellaneous Material Material Qantity. Unknown Material Condition: Good Physical Description (layers): Pink fibrous material; Silver wra Asbestos Detected (layers): Negative; Negative fbcommendations: GENERAL -See Section VII VII. Recommendations CIEENERAL Y The laboratory results of the potential ACM sampled at 996 Ptarmigan Rd, Vail, Cblorado, indicate that all thirteen (13) bulk - samples of drywall, stucco and insulation collected were reported as negative for asbestos. Therefore, no professional abatement activities are recommended to remove the above - referenced material prior to the demolition of the residence. 0 APPENDIX A CERTI FI CATI ON STATE OF COLORADO ASBESTOS CER'T`IFICATION* Colorado IDepartinentorPublic Health and £nvixrrwent Air Pollution C'.oRtrpt Division This certifies that Steve Shurtiiff Certification No: 1'1413 tors tint the requirvinents of 25 -7 -507, C,R.S. and Air Quality Control Commission Regulation No, $, Par B, and is hereby certified by die state of Colorado in the following discipline: Building Inspector* Issued: 6/12/2010 Expires on: 6/1212011 r I ms d avCA Re$ —kbv r •7krx i +nt/6rer«7r w1 d -ly.*h the red w.Jv rarar+.rlb.•tdra - w g reWere rent /1ads.un�iatr�•1vus ay.a�INmhron w z . • �1 AEROblO[Ogy LABORATORY .,�,,- -•� ASSOCIATES, INCORPORATED C LA"ATORY1A80RAT012Y Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746• www.aerobiolopY.net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. ���� �- Date Collected: Date Received: 07/22/10 07/22/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/22/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/22/10 Client Project Name: 996 Ptarmigan Rd. Vail, CO Project ID: 104811 Client Lab Sample Number Job ID: 104811 -1A Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos "in Bulk Building Materials. EPA - 600 /R- 93/116, July 1993. Homo- Number Asbestos Detected Non - Asbestos Non-Fibrous Matrix Sample Identification Physical Description of Sample; Additional Comments geneous es/no of La er % Fibers area % Material area % Material (composition Client Lab Sample Number WO = Wollastonite 104811 -1A White Joint Compound N 4,10% Negative T = Tar 100 C Trace —Less Than 1% NAC — Non - Asbestiform AC P — Perlite Laboratory Analyst Asbestos Laboratory Supervisor 98% O = Organic 104811 -1B White Tape N 4,15% Negative CELL 2 OP = Opaques DWO1 -01 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 D = Diatoms 104811 -1C White Compound w/ White Paint N 4,35% Negative 100 C 50% 104811 -1D White/Tan Drywall N 4,40% Negative CELL 50 98% 104811 -2A Yellow Fibrous Woven N 2,10% Negative FBG 2 DWO1 -02 104811 -213 White Compound w/ White Paint N 2,90% Negative 100 98% 104811 -3A Yellow Fibrous Woven N 4,2% Negative FBG 2 98% 104811 -3B White Tape N 4,4% Negative CELL 2 DWO1 -03 104811 -3C White Texture N 4,40% Negative 100 C 15% 104811 -3D White/Tan Drywall N 4,54% Negative CELL 85 G A = Amosite CELL = Cellulose Q — Quartz AC = Actinolite MW = Mineral Wool C = Carbonates f Y AN — Anthophyllite CHRY= Chrysotile FBG = Fiberglass SYN = Synthetic V = Vermiculite G = Gypsum CR = Crocidolite WO = Wollastonite M = Mica TR = Tremolite NTR = Non - Asbestiform TR T = Tar Paul Knappe Adam Humphreys Trace —Less Than 1% NAC — Non - Asbestiform AC P — Perlite Laboratory Analyst Asbestos Laboratory Supervisor FT = Fibrous Talc O = Organic AH =Animal Hair B = Binder OP = Opaques Page 1 of 5 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 D = Diatoms '%k,AERobio1oqy LAb ORATORy ASSOCIATES, INCORPORATED CONSULT LA 80RATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 wvwv.a erobioloav . net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. ��'J�, Date Collected: W 11 L4 d Date Received: 07/22/10 07/22/10 City, State ZIP Morison, CO 80465 U Date Analyzed: 07/22/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/22/10 Client Project Name: 996 Ptarmigan Rd. Vail, CO Project ID: 104811 Negative 98% CELL Job ID: NAC - Non- Asbestiform AC Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA - 600 /R- 93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous es/no Number of La er % Asbestos Detected Non-Asbestos Fibers area % on- Fibrous Material area % Matrix Material (composition V = Vermiculite Client Lab Sample Number DWO1 -04 1048114A White Tape N 4,5% Negative 98% CELL 2 NAC - Non- Asbestiform AC 1048114B White Joint Compound N 4,15% Negative AH =Animal Hair 100 C 1048114C White Texture N 4,35% Negative 100 C 1048114D White/Tan Drywall N 4,45% Negative 15% CELL 85 G DWO1 -05 104811 -5A Yellow Fibrous Woven N 3,2% Negative 98% FBG 2 104811 -513 White Tape N 3,8% Negative 98% CELL 2 104811 -5C White Texture N 3,90% Negative 100 C DWO1 -06 104811 -6A White Tape N 4,4% Negative 98% CELL 2 104811 -613 White Joint Compound N 4,15% Negative 100 C 104811 -6C White Texture N 4,15% Negative 100 C A = Amosite CELL = Cellulose Q - Quartz AC = Actinolite MW = Mineral Wool C = Carbonates _ AN = Anthophyllite g �r - FBG = Fiberglass V = Vermiculite . CHRY�hrysotile ¢ SYN = Synthetic G = Gypsum CR = Crocidollte WO = Wollastonite M = Mica TR = Tremolite NTR = Non- Asbestiform TR T = Tar Paul Knappe Adam Humphreys Trace -Less Than 1% NAC - Non- Asbestiform AC P - Perlite Laboratory Analyst Asbestos Laboratory Supervisor FT = Fibrous Talc O = Organic AH =Animal Hair B = Binder OP = Opaques Page 2 of 5 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 D = Diatoms '%k,A LAboRATORy ASSOCIATES, INCORPORATED CONSULTING LABORATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobioloay.net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. ���� Date Collected: d Date Received: ? 07/22/10 07/22/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/22/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/22/10 Client Project Name: 996 Ptarmigan Rd. Vail, CO Project ID: 104811 Negative 15% CELL Job ID: G Test Requested: 3002, Asbestos In Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA - 600 /R- 93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous (yes/no) Number of La er % Asbestos Detected Non- Asbestos Elm area % Non-Fibrous Material area % Matrix Material (composition CR = Crocidolite Client Lab Sam le Number DWO1 -06 104811 -613 White/Tan Drywall N 4,66% Negative 15% CELL 85 G DWO1 -07 104811 -7A Yellow Fibrous Woven N 5,2% Negative 98% FBG 2 104811 -713 White Tape N 5,5% Negative 98% CELL 2 104811 -7C White Texture w/ White Paint N 5,10% Negative 100 C 104811 -713 White Joint Compound N 5,15% Negative 100 C 104811 -7E White/Tan Drywall N 5,68% Negative 15% CELL 85 G PLO1 -01 104811 -8A Gray Plaster N 2,5% Negative 100 C 104811 -813 White Granular Plaster N 2,95% Negative 100 Q,C PLO 1 -02 104811 -9A White Foam N 3,5% Negative 100 104811 -913 Gray Plaster N 3,40% Negative 100 C Paul Knappe Laboratory Analyst Page 3 of 5 Adam Humphreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose AC = Actinolite MW = Mineral Wool AN = Anthophyllite FBG = Fiberglass CHRY= Chrysotile SYN = Synthetic CR = Crocidolite WO = Wollastonite TR = Tremolite NTR = Non- Asbestiform TR Trace —Less Than 1% NAC — Non - Asbestiform AC FT = Fibrous Talc AH =Animal Hair 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q — Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P — Perlite O = Organic B = Binder OP = Opaques D = Diatoms 1 %k,AERobio1oc j y LAbORATORy - ASSOCIATES, INCORPORATED S N CONSULTING LABORATORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 _ www.aerobioloay.net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. ���� 3, Date Collected: D Date Received: ? 07/22/10 07/22/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/22/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/22/10 Client Project Name: 996 Ptarmigan Rd. Vail, CO Project ID: 104811 Negative Job ID: Q,C Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous es/no _ . Layers( "/.) umber of Asbestos Detected Non - Asbestos Fibers area % Non-Fibrous Material area % Matrix Material (composition Client Lab Sample Number PLO 1 -02 104811 -9C White Granular Plaster N 3,55% Negative 100 Q,C PLO1 -03 104811 -10A White Granular Plaster N 2,10% Negative 100 Q,C 104811 -1OB Gray Plaster N 2,90% Negative 100 C PLO1 -04 104811 -11A Gray Plaster N 2,25% Negative 100 C 104811 -1113 White Granular Plaster N 2,75% Negative 100 Q,C PLO1 -05 104811 -12A White Granular Plaster N 2,10% Negative 100 Q,C 104811 -12B Gray Plaster N 2,90% Negative 100 C INSO1 -01 104811 -13A Pink Fibrous Material N 2,10% Negative 98% FBG 2 104811 -13B Silver Wrap N 2,90% Negative 20% FBG 80 Page 4 of 5 A = Amosite CELL = Cellulose AC = Actinolite MW = Mineral Wool AN = Anthophyllite FBG = Fiberglass CHRY= Chrysohle SYN = Synthetic CR = Crocidohte WO = Wollastonite TR = Tremolite NTR = Non - Asbestiform TR Paul Knappe Adam Humphreys Trace -Less Than 1% NAC — Non- Asbestifom AC Laboratory Analyst Asbestos Laboratory Supervisor FT = Fibrous Talc AH = Animal Hair 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q — Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P — Perlite O = Organic B = Binder OP = Opaques D = Diatoms &Robio ocy LAbORATORy ASSOCIATES, INCORPORATED CONSWING tABORAIORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood CO 80401 303.232.3746 www.aerobii oov.net DS Consulting, Inc. 5366 Flatrock Ct. 5 Date Collected: fl Date Received: 07/22/10 07/22/10 Morrison, CO 8046 Date Analyzed: 07/22/10 Steve Shurtliff #200860 -0 Date Reported: 07/22/10 Client Project Name: 996 Ptarmigan Rd. Vail, CO Project ID: 104811 Job ID: General Notes ♦ Negative indicates no asbestos was detected; the method detection limit is 1 %. ♦ Trace or " <1" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1 %. ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestiform variety of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM floor tile analysis is accepted under the NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples. Notes Required by NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP - approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746