Loading...
HomeMy WebLinkAboutM10-0167 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWWOWFVE Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT Permit #: M10-0167 ACOM Project #: PRJ10-0308 Job Address: 675 LIONSHEAD PL VAIL Status. . . : ISSUED Location.....: PATAGONIA,SUITE P214,ARRABELLE Applied . 08/25/2010 Parcel No...: 210106326001 Issued. . . 08/25/2010 Expires . .: 02/21/2011 OWNER ARRABELLE AT VAIL SQUARE LLC 08/25/2010 IN CARE OF NAME VAIL RESORTS MANAGEMENT CO 390 INTERLOCKEN CRESCENT STE 1000 BROOMFILED CO 80021 APPLICANT BILCOR CONTRACTING LLC 08/25/2010 Phone:303-972-5884 12779 W BELLEVIEW AVE LITTLETON CO 80127 License: 395-M CONTRACTOR BILCOR CONTRACTING LLC 08/25/2010 Phone:303-972-5884 12779 W BELLEVIEW AVE LITTLETON CO 80127 License:395-M Desciption: DEMO DUCT MOVE DIFFUSER ADD DUCT RUNS FOR TENANT IMPROVEMENT(PATAGONIA) Valuation: $5,200.00 **********«*******«**#*««««#*«*##*#««««««******#**«**#««***«««*********#***«****FEE SUMMARY****««««*««****«««*««««*«***«««********#«««««*««#*«*******##««##**««««**********«#*** Mechanical Permit Fee---> $120.00 Will Call------------> $4.00 Total Calculated Fees---> $154.00 Plan Check------------—-----> $30.00 Use Tax Fee------> $0.00 Additional Fees—---------> $55.00 Investigation--------------> $0.00 TOTAL PERMIT FEE---> $209.00 Total Calculated Fees--> $154.00 Payments-----------------> $209.00 BALANCE DUE---------> $0.00 APPROVALS Item:05100 BUILDING DEPARTMENT 08/25/2010 JRM Action:AP Item:05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond:42 (BLDG 2009)CARBON MONOXIDE DETECTORS REQUIRED TO BE INSTALLED PER 2009 IRC R315 DECLARATIONS I hereby acknowledge that 1 have read this application,filled out in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4 PM. Signature of Owner or Contractor Date L- rrC_ p)e✓sC � V"" - �- Print Name m e ch ca n ica I_pe rm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R100001159 Amount: $209.00 08/25/201011:58 AM Payment Method:Credit Crd Init: SAB Notation: VISA - COREY JOHNSTON ----------------------------------------------------------------------------- Permit No: M10-0167 Type: MECHANICAL PERMIT Parcel No: 2101-063-2600-1 Site Address: 675 LIONSHEAD PL VAIL Location: PATAGONIA, SUITE P214, ARRABELLE Total Fees: $209.00 This Payment: $209.00 Total ALL Pmts: $209.00 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ CL 00100003123000 CONTRACTOR LICENSES 55.00 MP 00100003111100 MECHANICAL PERMIT FEES 120.00 PF 00100003112300 PLAN CHECK FEES 30.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- r Oe, l eq D"Ortmerkotlaoinmuri t* nl . Sguth Fr9 n tag� e`en - .. �' III''•. MECHANICAL PERMIT Boiler/ Furnace&Fireplace plications --AgE Jude, Complete Mechanical Room Floor Plan with Dimensions a Boiler size&efficiency Combustion Air Duct Size and Location n Equipment Cut Sheets for Fireplaces/Log Sets o Flue detail or Vent size,location&termination (Manufacturer's info shovjin2 make, model&approval listing) Gas Piping layout including development length calculations Office Use: o Heat Loss Calculations Project#:_—,e Project Street Address: Building Permit#: 675 Llonshead Pl.Vail P214 Mechanical Permit#' (Number) (Street) (Suite#) Lot#: Block# Su division: Building/Complex Name: Arrabe le'at Vail Square-Patagon i - '.........._......._....... Define Scope and Location of Work: Demo duct, move Contractor Information: Bilcor Contracting LLc diffusers and duct,add Duct runs. Company: 9 ...'Company Address: 12779 W Belleview Ave City. Littleton State: Co Zip:80127 ruse additional sheet if necessary) Contact Name: Cory Johnston _ _ _ .:,...... ... _ .__... 720-373-4378 _ , o Gas Piping Included Contact Phone: Gas Piping by Others E-mail bilcorllc @msn.com t o Wood to Gas Fireplace Conversion Town of V it Contract Regis ration No.: 395-M ;Boiler Location: ;i anterior( ) Exterior( ) Other( ) Number of Existin�Fire laces: `--._ _..__......__._...-._ _._•_ Conti Sig ure(required) _ g p Gas Appliances Gas Logs _ Wood/Pellet Property Information _ �._,._._..,,v .__..._..._...,►_._... __..._...,. I Patel#: 210106326001 VNumber of Proposed Fireplaces: (For parcel#.contact Eagle County Assessors Office at 970-328.8640 or Gas Appliances Gas Logs Wood/Pellet 1visawww.eaglecounty.us/patie) �._ ------ Tenant Name; Patagonia ;Type of Building: (Commercial Properties) — `Single-Family( ) Duplex( ) Mulfi-Family( ) Commercial r,) i Owner Name. Arrabell at Vail Square LLc-Vail Resorts 'Restaurant( ) Other( ) �..._...:..__..,., ,_:_.._....-_._,.._,,..,._ Date Received: Complete Valuation for Mechanical Permit:(including fireplaces) ; Mechanical$ $5200.00 EAUG 3 2010 c� C:\cdev\Forms`•pen-niLs\building�neehnnical_rrr^•i._0101 10 � VXI a... . .R�..- --SID -CQ/y7 s �O € s e 4 PATAGONIA THE ARRABELLE AT VAIL SQUARE VAIL, CO 81657 OCTOBER 2010 r t 1 d f S } S s: i- f xx, C L-- TESTING om plete PO BOX 27706 t { ADJUSTING Mechanical DENVER, CO. 8=7 TABB CERTIFIED Balancing, Inc. FAX =-srz-74W k SYSTEM.BALANCING PHONE 303-948-6429 U OCT 11 2010 TOWN OF VAIL , PAGE 8104 TESTING COMPLTrTE P.O. BOX 27706 ADJUSTING MECHANICAL DENVER, CO. 80227 SYSTEM BALANCING BALANCING, INC. FAX 303-972-7453 TABB CERTIFIED PHONE 303-948-5429 GENERAL INFORMATION g PROJECT PATAGONIA LOCATION THE ARRABELLE AT VAIL SQUARE,VAIL, CO 81657 ARCHITECT - TODD ARCHITECTURE MECHANICAL ENGINEER SHEETMETAL CONTRACTOR BILCOR CONTRACTING BALANCING CREW GCATLETT J.CATLETT DATE OCTOBER 2010 { INSTRUMENTS USED t FLOW HOOD ALNOR / SHORTRIDGE ANEMOMETER DAVIS TYPE LCA 6000 SPEED INDICATOR BIDDLE TYPE 9915 AMMETER / VOLTMETER AMPROBE TYPE DIGITAL ' INCLINED DRAFT GAGE DWYER 0-0.25" 0-0.50" 400" f MAGNEHELIC GAGE 0-0.50" 0-1.0" 0-2.0" 0-4.0" 0-8.0" PRESSURE GAGE -30--+30 PSI 0-60 PSI 0-100 PSI k PRESSURE GAGE DIFFERENTIAL BARCO 0-50" 0-100" 300" 500" 0-100' PYROMETER ALNOR THERMOMETERS FLUKE TYPE 52 MICROMANOMETER ALNOR TYPE 530 o P cad coke TABB TwhWd= NO ,ed Names Jimmie Catlett TARS IDs=957485T 6' ft- Rq*st m Dates 12/31/2011 /J, k 12/3lawo PROJECT ALTITUDE 5200' FLOW HOOD CORRECT 1.10 APPLIED TO;AREA(K FACTOR) X VELOCITY r STATIC PRESSURE CORRECTION 1.21 RECORDED PRESSURE READINGS ARE MEASURED X CORRECTED COWLETE E MECHANICAL Page 8104-A BALANCING, INC. NOTES JOB• PATAGONIA FCU-D2-12-1 OUTLET#I IS ATTACHED TO FCU-D2-13. PAGE 3 FCU-D2-9 FCU-D2-9 IS NOT OPERATIONAL AT TIME OF BALANCE. ONLY ONE DIFFUSER = WAS RELOCATED FROM THIS FCU. PAGE 6 FCU-D2-9 FCU-D2-9 IS NOT OPERATIONAL AT TIME OF BALANCE. ONLY ONE DIFFUSER OSA WAS RELOCATED FROM THIS FCU. PAGE 7 4- F S } z C s t COMPLETE MECHANICAL PAGE 8104-1 BAIANCI NG. INC. AIR SYSTEM RECAP SHEET JOB: PATAGONIA ZONE OR REQ'D ACT"L %OF FUNCTION UNIT NO. MAIN CFM CFM REQ'D OSA REMARKS PAGE SUPPLY FCU-D2-1 1-10 2050 1763 86 407 SEE NOTE PAGE 2-3 SUPPLY FCU-D2-1 11-19A 2000 1995 100 277 4-5 SUPPLY FCU-D2-9 20-26 2000 0 SEE NOTE PAGE 6 SUPPLY FCU-D2-13 387 7 TOTAL 6050 3758 62 z 5 4 t. i s i 7 p 4'' Complete Page 8104-2 Mechanical Date 10-01-10 Balancing, Inc. Contrac BILCOR Balance:J.C. EQUIPMENT`DATA A) PROJECT PATAGONIA UNIT NO. FCU-D2-12 PLAN LOC. MAKE INTERNATIONAL ENVIROMENTAL CORP MODEL NO. HBC2000051647 SER. NO. 961451-30-2 RATING 2000 CFM ® 0.6" E.S.P. INITIAL RPM 803 4: FINAL RPM 803 B) MOTOR BALDOR HP. 1 RATED EFF/PF 66/72 TYPE NONE GIVEN PH. 1 RATED SPEED 1725 MEAS.VOLTS (L/L) 209 SF. 1.15 RATED VOLTS 115-230 INITIAL AMPS 4.91 FR. 56/56H RATED AMPS 13.4/6.7 } MEAS.VOLTS (L/G) S F AMPS NONE GIVEN FINAL AMPS 4.91 C) STARTER SIZE THERMALS (E)GSTS AMP. RATING THERMALS (REQ'D) AMP. RATING OTHER BUILT IN OVERLOAD PROTECTION r E D) DRIVEN AK59 SHEAVE X BORE 1" DRIVER IVP40 SHEAVE X BORE 7/8" BELTS A28 SIZE X NO. BELTS 1 MOT.ADJ. IN/OUT CL. DIST. DRIVE CHANGE NONE BELT CHANGE NONE E) FILTERS IN -0.09 IN. OUT N/A IN. DROP 0.09 IN. 1 HEAT COIL IN IN. OUT IN. DROP IN. COOL COIL IN N/A IN. OUT -0.36 IN. DROP -0.36 IN. FAN IN -0.36 IN. OUT 0.21 IN. DROP 0.57 IN. G) PUMP IN PSI OUT PSI RISE PSI FT DEAD HEAD IN PSI OUT PSI RISE PSI FT H) REMARKS AREA= SQ. FT.X FPM= CFM FINAL: SQ. FT.X FPM= CFM =` i COMPLETE MECHAPIICAL PROJECT PATAGONIA PAGE NO 8104-3 BALANCING LOCATION VAIL. CO DATE 10-01-10 FAN SYSTEM FCU-D2-12 BALANCER j.c. COWRACTOR BILCOR CONTRACTING SIZE FlEQLTII2ED TEST 1 TEST 2 TEST 3 FINAL OPENING PLAN kCT*l AREA VEL CFM VEL % VEL orb VEL % VEL CFM % REMARKS CU-132-12-1 4'SLT 1.16 259 300 SEE NO'T'E PAGE 2 4'SLT 1.16 194 225 240 124 200 232 103 3 4'SLTI 1.16 194 225 200 103 200 232 103 4 4'SLT 1.16 194 225 180 93 190 220 98 5 4'SLT 1.16 194 225 200 103 200 232 103 E 6 4'SLT 1.16 194 225 1701 881 200 232 103 7 4'SLT 1.16 194 225 170 88 195 226 101 8 4'SLT 1.16 151 175 150 99 145 168 96 9 4'SLT 1.16 151 175 150 99 145 168 96 100% OPEN 10 4'SLT 1.16 43 50 30 70 45 52 104 f TOTAL 2050 1763 F: Y t 2 - r z _ e I` y. REMARKS AlRBAL 7 Complete Page 8104-4 MecllaIItcal Date 10-01-10 Balancing, Inc. Contrac BILCOR Balance:J.C. E9UIPMENT DATA A) PROJECT PATAGONIA UNIT NO. FCU-D2-10 PLAN LOC. MAKE INTERNATIONAL ENVIROMENTAL CORP MODEL NO. HBC2000051647 SER. NO. 961451-40-1 RATING 2000 CFM ® 0.6" E.S.P. INITIAL RPM 847 FINAL.RPM 847 B) MOTOR BALDOR HP. 1 RATED EFF/PF 66/72 TYPE NONE GIVEN PH. 1 RATED SPEED 1725 t MEAS.VOLTS (L/L) 208 SF. 1.15 RATED VOLTS 115-230 = INITIAL AMPS 5.43 FR. 56/56H RATED AMPS 13.4/6.7 MEAS.VOLTS (L/G) S F AMPS NONE GIVEN 4 FINAL AMPS 5.43 3 C) STARTER SIZE THERMALS (EXIS71 AMP. RATING THERMALS (REQ'D) AMP. RATING OTHER BUILT IN OVERLOAD PROTECTION D) DRIVEN AK59 SHEAVE X BORE 1" DRIVER 1VP40 SHEAVE X BORE 7/8" BELTS A28 SIZE X NO. BELTS 1 MOT. ADJ. IN/OUT CL. DIST. DRIVE CHANGE NONE BELT CHANGE NONE p E) FILTERS IN -0.13 IN. OUT N/A IN. DROP 0.13 IN. r HEAT COIL IN IN. OUT IN. DROP IN. COOL COIL IN __ N/A IN. OUT -0.41 IN. DROP -0.41 IN. FAN IN -0.41 IN. OUT 0.23 IN. DROP 0.64 IN. r G) PUMP _IN PSI OUT PSI RISE PSI FT DEAD HEAD IN PSI OUT PSI RISE PSI FT t: H) REMARKS AREA= SQ. FT.X FPM= CFM FINAL: SQ. FT.X FPM= CFM COMPLETE MECHANICAL PROJECT' PATAGONIA PAGE NO 8104-5 ELMANCING LOCATION VAIL, CO DATE 10-01-10 FAN SYSTEM FCU—D2-10 BALANCER J.C. COMMACPOR BILCOR CONTRACTING SIZE REQUIRED TEST 1 TESr 2 TESr 3 FINAL OPENING PLAN kCT"I AREA VEL CFM VEL % VEL % VEL % VEL CFM % REMARKS ¢F E FCU—D2-10-11 4'SLT 1.16 190 220 240 127 200 232 105 12 4'SLT 1.16 259 300 270 104 260 302 101 13 4'SLTI 1.16 259 300 210 81 250 290 97 14 4'SLT 1.16 259 300 220 85 245 284 95 15 4'SLT 1.16 259 300 250 97 270 313 104 16 4'SLT 1.16 259 300 230 89 245 284 95 100% OPEN 17 24/24 1.161 52 60 80 155 55 64 106 ': 18124/24 1.16 26 30 90 348 25 29 97 19 18"0 1.16 78 90 60 77 80 93 103 19A 24/24 1.16 86 100 50 58 90 104 104 TOTAL 2000 1995 r x s; E- 3 f Z i RENIAR S AIRBAL j' Y' F' f COMPLETE MECHANICAL PROJECT PATAGONIA PAGE NO 8104-6 BALANCING LOCATION VAIL, CO DATE 10-01-10 FAN SYSTEM FCU-D2-9 BALANCER J.C. CONIRACPOR BILCOR CONTRACTING 4 SIZE MUMED TEST 1 IESr 2 TEST 3 FUgAL OPENING PLAN VEL CFM VEL % VEL % % VEL CFM % REMARKS FCU-D2-9-20 4'SLT 1.16 216 250 SEE NOTE PAGE 21 4'SLT 1.16 259 300 22 4'SLT 1.16 259 300 23 4'SLT 1.16 259 300 24 4'SLT 1.16 259 300 25 4'SLT 1.16 237 275 26 4'SLT 1.16 237 275 TOTAL 2000 I L 1 1+ k l i E f i �pp b' Y- S- f REMARKS g ARREML 1- t COMPLETE MECHANICAL PROJECT PATAGONIA PAGE NO 81047 BAIANCING LOCATION VAIL, CO DATE 10-01-10 R' FAN SYSTEM MUA FOR OSA BALANCER J.C. CONTRACPOR BILCOR CONTRACTING t SIZE REQUERED TESL' 1 17Sr 2 TEST 3 FINAL OPENING PLAN kCrI AREA VEL CFM VEL % VEL % % VEL CFM % REMAIt O ` FCU-D2-9 10"0 0.58 483 280 SEE NOTE PAGE FCU-D2-10 1010 0.58 483 280 590 122 478 277 99 FCU-D2-12 10"Ol 0.58 681 395 832 122 701 407 103 FCU-D2-13 10"0 0.58 681 395 896 132 668 387 98 r z- s REMARKS AIRBAL f M10-0167: Entries for Item:390 - MECH-Final 09:58 03/14/2013 Action Comments By Date Unique_ Key AP Martin 10/21/2010 A000137 924 Total Rows: 1 Page 1