The architecture of an IP Fire SeriesT"' fire control network is comprised of a
series of IP-based distributable modules.These modules include alternate
configurations of analog loop and NAC circuit modules(ALM-xy), standard
display modules (SDM), annunciator control modules(ACM)and other
specialized modules noted in other documents.
The Analog Loop Module (ALM)communicates with all other modules Features
installed on the network through an Ethernet connection and is addressed . Unique IP address
through the ALM's unique IP address.
• 3000 event history log per module
The ALM manages Class A/B Signaling Line Circuits(SLC), Class A/B • May be distributed through facility
Notification Appliance Circuits(NAC)or both, depending on the module in any number up to system max
of 50 modules
configuration. The number of each type of circuit is specified by the trailing 2 Continues to operate with loss of
digits in the ALM part number. Thus, an ALM-12 would have a single SLC • system communication
and two NAC circuits. . Synchronizes data with network
when communication link is
Once programmed, each ALM maintains an integral 3000 event history log restored
and will continue to operate its connected circuits even if communication . SmokeClearT"^ alert signals when
with the remaining network is severed. Upon rejoining the network,the ALM smoke has cleared detector
will synchronize its data with the remaining modules. chamber
• Can be distributed alone,with
ALM modules may be located anywhere within a facility and can be other modules,with central or
packaged in a variety of remote or pre-configured enclosures that allow for local power
additional modules, common relay cards or displays to be packaged with the • Supports SLC circuits, NAC
ALM. circuits-or a combination of each
• Power Limited Class A/B NAC
Remote ALM's can draw power from a central location or can be furnished circuits rated at 24V/3A each
with an integral 24V, 8A power source and battery charger. ALM's may be • Each Class A/B SLC circuit
added to the network in any number up to the system maximum module supports 126 XP and Discovery
count of 50. detectors and devices on same
circuit
Each power limited NAC circuit can be synchronized and is rated at 24V/3A. • Modular listing
Each SLC loop supports up to 126 addressable detectors(XP-95, Discovery ' Green/RoHS Compliant
or both on the same SLC circuit)as well as a variety of addressable
input/output modules.
Listinqs
IP Fire SeriesT"' systems feature SmokeClearT"" to report when smoke has
cleared the chamber of any detection device.This information is reported to UL File: S24573
the panel and recorded in the history log allowing first responders to CSFM: Pending
MEA: Pending
determine the length of time that smoke was present at any given location
when evaluating conditions upon arrival. SmokeClearT"" will also put a
notification on the system when pull stations have been reset signaling that
the IP FireT"^ system can be reset.
Product Data Sheet Number Rev/Revision Date = _ —
IPF SeriesT"" ALM 1020 1.4/10/1/2009 IPFIRESERIES"
O Copyright 2008 AsBuilt Engineered Systems, Inc.
Enqineer Specification
The contractor shall furnish and install, where indicated on the plans, central or distributed ALM-xy modules to provide
for analog addressable SLC circuits capable of supporting 126 detectors and i/o devices in any combination and power
limited 3A NAC circuits and attached devices capable of synchronized operation. The ALM-xy shall maintain an
integral 3000 event history log and be capable of stand-alone operation should communication with the network be
interrupted.The ALM-xy shall be capable of synchronizing its data with the remaining network when communication is
restored. The ALM-xy must be distinguished by a unique IP address for secure communication and to distinguish it
from all other modules on the network.The ALM-xy shall be capable of remote installation and shall be capable of
being powered from a central 24V system source or with an integral 8A power supply and battery charger. The ALM-xy
shall contain an integral USB 2.0 Type A communications port for program upload/download to/from a USB Mass
Storage Device.The ALM-xy shall also be programmable through the USB ports of any attached VPM and SDM
modules.The ALM-xy must be UL listed and UL listed as compatible with the AsBuilt IP Fire Series network fire
controls.The ALM-xy modules shall be As Built Engineered Systems part numbers ALM-10,ALM-02 and ALM-12.
Technical Data Each SLC Circuit
Max Circuit Voltage: 24V
ALM-12 Max Current: 0.5A
Quiescent Power Draw: 170 mA
Alarm Power Draw: 195 mA Each NAC Circuit
Max circuit voltage: 24V
ALM-10 Max Current: 3A
Quiescent Power Draw: 149 mA Max RMS Operating Current(Single Notification
Alarm Power Draw: 155 mA Appliance: 0.5A
ALM-02 Maximum allowed:
Quiescent Power Draw: 143 mA Synchronized: max: 50
Alarm Power Draw: 180 mA Non-Synchronized: max 30
Power Limited
Orderinq Information
Part Number Data Sheet Description
ALM-10 1020 ALM Module with One Analog Loop SLC
ALM-02 1020 ALM Module with Two 24V NAC Circuits/3A each
ALM-12 1020 ALM Module with One SLC/2NAC circuits
Related Modules,Accessorv Cards and Cabinets
VPM/SDM 1010 VPM/SDM Configuration/Display Modules
XP, DISC 2100, 2105 Detection Options for XP and Discovery Product Lines
DXP-xxx 2810-2812 Addressable Device Options
MBLR 1051 Optional Masterbox/Line Reversal card
CCR 1051 Optional Common Control Relay Card
KPD 1053 Optional QWERTY Keypad
UXB 1052 Optional USB Extension Card
UXB-KS 1052 Optional USB Extension Card/Key Activated
RTR, EPROT 1030 Optional Routers and Ethernet Protection Cards
RTR-3 1030 Fiber-Optic Long Haul Routers
Cabinets 1045 IPF-xy, IPF-XL and REM-Cabinet Options
IPF/IPF-XL 1050 IPF-xy, IPF-XL Pre-Configured Systems
Product Name Data Sheet Number Rev/Revision Date = - -
I PF SeriesT"" ALM 1020 1.4/10/1/2009 tP FIRE SERIES"
As Built Engineered Systems, Inc. Phone: (508)788-8333 ■ ��,
1451 Concord Street Fax: (508)788-8334 �� � � ' I�
Framingham, MA 01701-7782 Contact: info(a�asbuiltes.com
USA Visit: www.asbuiltes.com Engineered Systems
O Copyright 2008 AsBuilt Engineered Systems, Inc.