Loading...
HomeMy WebLinkAboutData Sheet 1045 IPF Series Module Cabinetry Data Sheet 1045 /�l � B u I �t Engineered Systems IP Fire SeriesT"' Distributed System �T � � � Cabinet Options i � • IPF � � . • IPF-XL � �� • REM-R -� • REM-C Description Features The IP Fire SeriesT"' from AsBuilt Engineered Systems is an IP-based Fire ' �P FireT"" Series Cabinets available Control network consisting of a series of addressable control modules that in 4 basic sizes can be distributed throughout any type of facility. • Chassis and door options provide for a variety of configurations Distributed modules are housed in AsBuilt IPF SeriesT"" cabinets that are • Cabinets can be installed centrally available in a variety of configurations to accommodate any building or distributed throughout facility requirement. • All cabinets are available with blank doors for installation in Large (IPF-XL), medium (IPF-xy), and small (REM)cabinets can be electrical rooms or closets configured to accommodate single modules, multiple modules,with or • Cabinet configurations for central without displays and with or without local power. or integral power distribution • IPF-XL cabinets can accommodate The standard IPF cabinet(IPF-xy)fits between standard stud placements, up to two PS-24 power supplies measures 14Wx23Hx4.5 deep and is available with three different door for local/distributed power and up options. The IPF-xy cabinets are key-enabled. to two APS-4 battery chargers • IPF-xy and REM cabinets surface, The larger IPF-XL can accommodate a display and up to 4 additional system flush or semi-flush mounting modules, common control cards,two power supplies and an additional 8A of . �pF-XL surface or semi-flush power available for charging batteries. IPF-XL cabinets are available in a mounting variety of configurations behind a clear locked Lexan door.The IPF-XL . IPF-XL left or right hand hinged for measures 22Wx23Hx5.5D. side-by-side mounting REM series cabinets measure 14Wx10.5Hx4.5D or 9Wx12Hx3D and house requirements from one to three system modules–with or without displays. REM cabinets • Key-activated USB extension slots with displays are key-enabled. (UXB) bring on-board US ports to front of cabinet An REM-R enclosure can be configured to mount a single module, a single module with space for common control cards or two modules–all with or without a system display modules(VPM or SDM).The REM-R and REM-C Listinqs enclosures do not provide room for a power source.The REM-R and REM-C must be powered with 24V from a separate IPF distributed enclosure. Power UL File: S24573 monitoring is provided by the power supply monitor module(PSM)at the CFSM: Pending power source. MEA: Pending The variety of cabinet configurations and distributed system modules allow the system designer to cost effectively deploy the fire system network throughout the building. Also refer to DS 1050, IPF Series Pre-Configured Systems for more options. Product Data Sheet Number Rev/Revision Date = _ — IPF SeriesT"^ Distributed Cabinet Options 1045 1.4/ 10/1/2009 IPFIRESERIES" O Copyright 2008 AsBuilt Engineered Systems, Inc. IPF-xy, IPF-XL and REM Cabinet Options Product Name Backbox Dimensions SDM/ Module PS-24 APS-4/ General Contact QWERTY VPM Slot' PSM SlotsZ (Keyboard) IPF-xy3 14Wx23Hx4.5D 1 1 1 1 2 - IPF-xy-K3 14Wx23Hx4.5D 1 1 1 1 2 1 IPF-xy-ND3 14Wx23Hx4.5D - 1 1 1 - - IPF-XL-xy3 22Wx30Hx5.5D 1 4 2 2 2 - IPF-XL-xy-K3 22Wx30Hx5.5D 1 4 2 2 2 1 IPF-XL-xy-ND3 22Wx30Hx5.5D - 4 2 2 - - REM-C-1 9Wx12Hx3D - 1 - - - - REM-R-M2 14Wx10.5Hx4.5D - 2 - - - - REM-R-SDM 14Wx10.5Hx4.5D 1 - - - - - REM-R-SDM2 14Wx10.5Hx4.5D 1 2 - - - - REM-R-SDM2C 14Wx10.5Hx4.5D 1 1 - - 2 - �May contain ALM-12,ALM-10,ALM-02,RTR-1 or RTR-2(in applicable configurations)modules. z General Contact Slots may hold any combination of Common Control Relay(CCR)boards and/or Line Reversal/Masterbox(MBLR) 3The xy represents the base configuration as included for the panel corresponding to the available ALM configurations, whereas x represents the number of detector Signaling Line Circuits(SLC's),and y represents the number of Notification Appliance Circuits (NACs). Orderinp Information Part Number Data Sheet Description Cabinets 1045 IPF-xy, IPF-XL and REM-Cabinet Options Related Modules,Accessorv Cards and Cabinets IPF/IPF-XL 1050 IPF-xy, IPF-XL Pre-Configured Systems VPM/SDM 1010 VPM/SDM Configuration/Display Modules ALM 1020 Analog SLC and NAC Circuits XP, DISC 2100, 2105 Detection Options for XP and Discovery Product Lines DXP-xxx 2810-2818 Addressable Device Options MBLR 1051 Optional Masterbox/Line Reversal card CCR 1051 Optional Common Control Relay Card KPD 1053 Optional QWERTY Keypad UXB 1052 Optional USB Extension Card UXB-KS 1052 Optional USB Extension Card/Key Activated RTR, EPROT 1030 Optional Routers and Ethernet Protection Cards SDM-NY 1010 Standard Display Module NYC Enclosure Product Name Data Sheet Number Rev/Revision Date = _ _ IPF SeriesT"' Distributed Cabinet Options 1045 1.4/ 10/1/2009 IPFIRESERIES" As Built Engineered Systems, Inc. Phone: (508)788-8333 ■ 1451 Concord Street Fax: (508)788-8334 �� � � ' I� Framingham, MA 01701-7782 Contact: info asbuiltes.com USA Visit: www.asbuiltes.com Engineered Systems O Copyright 2008 AsBuilt Engineered Systems, Inc.