Loading...
HomeMy WebLinkAboutData Sheet 1051 IPF Common Cards Data Sheet 1051 /�l � B u I �t Engineered Systems IP Fire SeriesTM Common Cards �`�`�� ���_��� • CCR �����. :, �� • M B L R ��^s � .� .. .. . -,.� f. ��. Description - The IP Fire SeriesT"' from AsBuiltT"" Engineered Systems is a revolutionary IP-based fire control network consisting of a series of addressable control modules that can be distributed throughout any type of facility. Features Core modules connect to other core modules to form the fire protection Common cards can be connected system. No central processing unit is required.With no single point of • to any IP Fire SeriesT"' distributed failure, distributed modules provide the greatest degree of building display module(VPM/SDM) protection.Any module failure will not impact the operation or timely Common cards may be daisy response of any of the remaining modules. � chained up to two per networked Both distributed network systems and pre-configured central systems module require the capability to accommodate common control or panel level • Common Control card (CCR) functions. provides relays for Common Alarm, Common Trouble and The IP Fire SeriesT"" panel-level common cards can connect to any Common Supervisory display module located anywhere on the network. • CCR relays NO/CO/NC, rated at 2A @30VDC Resistive Load The Common Control Relay Card (CCR)provides for Common Alarm, • City tie Masterbox/Line Reversal Common Trouble and Common Supervisory relays(NO/CO/NC) Card activated by events anywhere on the fire control network.The three • Simple ribbon cable connection relays are rated at 2.OA @30 VDC Resistive load each. • Mounts directly onto cabinet chassis The CCR can be mounted with any VPM or SDM installed on the • Green/RoHS Compliant network fire system by a simple ribbon cable connection. Multiple instances of the CCR may be installed as required on each display module installed on the network and up to two CCR boards may be daisy chained together off of any single network module. The CCR is mounted directly to the system chassis within the cabinet. The Masterbox/Line Reversal card (MBLR) is also mounted with any display module installed on the network fire system by a simple ribbon cable connection. If present,the MBLR may be daisy-chained directly off of the CCR. The MBLR is mounted directly to the system chassis Listinqs within the cabinet. UL File: S24573 IP Fire SeriesT"" network modules will continue to operate CFSM: Pending independently during communication loss. Since the CCR and MBLR MEA: Pending may be installed in multiple instances and located in distributed enclosures throughout the facility, redundant connections to outbound signaling systems such as dialing devices, digital transmitters or other notification systems add security to the installed system by adding redundant paths to external reporting agencies. Product Data Sheet Number Rev/Revision Date = _ — IPF SeriesT"" Common Cards 1051 1.3/5/1/2009 IPFIRESERIES" OO Copyright 2008 AsBuilt Engineered Systems, Inc. \J =_r ;_;_; � �_,'� i_� �-� _� =� - --�FYRk:�-�7TQ2Ury� - � � �� G - �� �- & �' F z ' > �_.� �- Di � � +�S �� �l i. i..rr ��:����� i > v V � � �r� '� P� '� ��-�, � CCR Common Control Relay Card (CCR) Masterbox Line Reversal Card (MBLR) Jumper/Switch Description Jumper/Switch Description J1 Alarm Input Wiring Location J1-J3 Line Reversal Wire Connectors(Alarm,Trouble,Supervisory) J2 Trouble input Wiring Location J4 Municipal Box Suita6le forconn.to Masferbox coils rated down to 13JS� J3 Supervisory Input Wiring Location JPi-JP2 MBLR Configura[ion PMS(Apply to ALARMfiROUBLE Only) JP1 Inter-Board Connector 1(In) JP3-JP4 Inter-Board Connec[ors JP2 Inter-Board Connector 2(Ou[) JP5 Onboard Municipal Boz Disable Pins 1-2:Enable Pins 23:Oisable • NC-NOrmallY�losed 51 Municipal Box Disable Switch • CO-Common D1 Municipal LED S[atus(On:Disabled,Off-Enabled) • NO-NOrmallyOpen • �JPl-1P2:PIN51-2:OperateNOrmally • JP1 and JP2 chain connectors allow connections[o the ALM,and[o ano[her General • PINS 2-3:Combines AL4RM and TROUBLE conditions into one circuit Relay Board(GRB),or to a Line Reversal/Mas[erbox Board(MBLR) • No2e:when mmbined,only 11(nL4kM)Is operaEional. Technical Data CCR MBLR Quiescent Power Draw: 0 mA Quiescent Power Draw: 0 mA Alarm Power Draw: 69 mA Alarm Power Draw: 92 mA Orderinq Information Part Number Data Sheet Description CCR, MBLR 1051 Optional Common Control Relay Card Related Modules,Accessorv Cards and Cabinets Cabinets 1045 IPF-xy, IPF-XL and REM-Cabinet Options IPF-xy, XL 1050 IPF-xy, IPF-XL Pre-Configured Systems VPM/SDM 1010 VPM/SDM Configuration/Display Modules ALM 1020 Analog SLC and NAC Circuits UXB, UXB-KS 1052 Optional USB Extension Card KPD 1053 Optional QWERTY Keypad Product Name Data Sheet Number Rev/Revision Date = _ — IPF SeriesT"' Common Cards 1051 1.3/5/1/2009 IPFIRESERIES-" As Built Engineered Systems, Inc. Phone: (508)788-8333 ■ �•: 1451 Concord Street Fax: (508)788-8334 �� � � ' I� Framingham, MA 01701-7782 Contact: info(a�asbuiltes.com USA Visit: www.asbuiltes.com Engineered Systems OO Copyright 2008 AsBuilt Engineered Systems, Inc.