HomeMy WebLinkAboutData Sheet 2108 IPF Series DISC-T Data Sheet 2108 /�l � B u I �t
Engineered Systems
IP Fire SeriesT"'
Discovery Thermal �a .;
Detector ��►.� ,,,� ���`
.� � ='� � -
• DISC-T - . �
�
Description
The AsBuilt intelligent analog addressable thermal detector(DISC-T)
operates seamlessly with the AsBuilt IP Fire SeriesT"" network fire control.
The DISC-T communicates to and is managed and controlled by the IPF
SeriesT"" analog loop module(ALM).
DISC-T heat detectors have a common profile with the photoelectric and Features
ionization smoke detectors but have a low air flow resistance case made
of self extinguishing white polycarbonate. The DISC-T has two red colored • Discovery detectors distribute
LED's that light steady when in an alarm condition and flash briefly when intelligence across the installed
polled by the ALM. The dual LED's provide for 360 degree visibility. system
• Sleek, non-fading white
Operation polycarbonate enclosure
• Zero insertion force base
The DISC-T heat detector uses a single thermistor to sense the air 5 user selectable modes combine
temperature at the detector position. The thermistor is connected in a �
resistor network,which produces a voltage output dependant on static response with rate-of-rise
temperature. features
• Powerful transient rejection
The design of the resistor network,together with the processing algorithm algorithms
in the microcontroller, gives an approximate linear temperature Conventional device mode
characteristic. This signal is further processed, depending on the response �
mode selected, and converted to an analog output for transmission to the • Patented XPert programming card
ALM. eliminates addressing errors during
system installation and maintenance
Upon crossing the alarm threshold the detector will make the . Alarm flag sends signal to system
determination that an alarm condition exists and send a signal to the ALM even when device is not being
that interrupts the normal polling process to signal the alarm condition. interrogated
The ALM puts the changed state on the IP network and all outputs . Wide variety of addressable
associated with the specific detector are activated. input/output devices
• Relay and synchronized temporal
Like all Discovery devices,the DISC-T has five pre-programmed user sounder bases
settings that may be accessed and changed from the IPF Series network . Green/RoHS Compliant
control. Further, the pre-programmed settings are utilized in establishing
the automatic temperature response values in place with the IPF
Day/Night sensitivity programming.
With DISC-T heat detectors,the five user modes correspond to different Listinqs
combinations of fixed temperature settings with or without rate-of-rise
(ROR)features. UL File: S5022
CSFM: 7270-1394:119
Settings are classified as static(S)if it incorporates fixed temperature MEA: 294-95-E-4
settings only. With this setting,the detector will not respond below its
minimum static response temperature even when exposed to high rates of
rise of air temperature. This type of setting is therefore suitable for areas
such as kitchens or boiler rooms where large, rapid temperature changes
ara rnnci�lara�l nnrmal
Product Data Sheet Number Rev/Revision Date = _
IPF SeriesT"" DeteCtors DISGT 2108 1.4/10/1/2009 IPFIRESERIES'"
OO Copyright 2008 AsBuilt Engineered Systems, Inc.
Enqineer Specification
The contractor shall furnish and install, where indicated on the plans, intelligent thermal heat detectors with one of the
several addressable mounting base options available. The detector base will contain the patented XPERT programming
card which will permit the free interchange of sensor heads without requiring additional programming of the detector
head or attached base. The intelligent thermal heat detector shall be self reporting and contain dual integral LED's which
will flash intermittently when polled and shall latch when the unit goes into Alarm. The detector head shall have 5
programmable settings that can be accessed automatically or by manual setting from the fire control which will allow the
detector several response modes of the individual heat detector to be modified as required.The combination of the
detector head and twist lock mounting base shall be UL listed and UL listed as compatible with the AsBuilt IP Fire Series
network fire controls. The detector base shall be installed without regard to wire polarity. The thermal heat detector shall
be the AsBuilt model DISC-T.
Technical Data Five Pre-Proqrammed Response Settinqs
Operating Voltage: 17-28VDC . Mode 1 (135°F)25/50C (ROR)
Standby Current: 500uA avg./750uA peak
Alarm LED Current: 3.4mA
Remote Alarm Output: 5mA max • Mode 2 (150°F)25/50C (ROR)
Temperature range: -4°F to x(-20°C-x)
Relative Humidity(non-condensing):0%-95% . Mode 3 (150°F)25/50C (Static)
Clean-air Analog Value: 23+4/-0
Alarm Level Analog Value: 55 Mode 4 (200°F)55/80C (ROR)
Wire Supply: Two-wire supply, polarity insensitive �
x-see response settings
• Mode 5 (200°F)55/80C (Static)
Orderinq Information
Part Number Data Sheet Description
DISC-T 2108 Intelligent Analog Addressable Thermal Detector(model 58000-450)
DXP-6 2310 6" Low Profile Base w/Expert Card (model 45681-250)
DXP-4 2310 4" Low Profile Base w/Expert Card (model 45681-210)
DXP-RLY 2310 6" Low Profile 4-wire Relay Base (model MB-RLYT-AA)
DXP-SND/T 2310 6"Low Profile 4-wire Sounder Base (model MB-SDRT-AA)
DXP65 2310 Sync Module for Temporal Sounder Bases(model MB-SDRT-SM/G/R)
DXI 2300 Line Isolator(55000-750)
DXP-LIB 2300 Isolating Base for DXI only(45681-211)
DXP-IB 2300 Line Isolating Base for Use with XP/DISC Detectors(45681-321)
DXP-XPC Additional XPERT programming card
DXP-XPC#A Order"A"for Addresses 1-42, "B"for 43-84, "C"for 85-126,#for Loop#
DXP-126 126 Pre-Programmed XPERT cards
DXP-REM Remote LED(24V)
Related Data Sheets
Discovery Detectors: DISC-P, 2106; DISC-I, 2107; DISC-M, 2109
XP Detectors: XP-P, 2101;XP-I, 2102;XP-T, 2103;XP-M, 2104
Addressable Devices: DXP-PIM/MPIM, DXP-PID/MPID, 2810; DXP-IOM, 2812; DXP-SDR, 2814, DXP-
2PID, 2816; DXP-OCR, 2818
Addressable Base Options: All Bases, 2310
Product Name Data Sheet Number Rev/Revision Date = _ —
IPF SeriesT"' Detectors DISGT 2108 1.4/10/1/2009 fPFIR�seRies'°
As Built Engineered Systems, Inc. Phone: (508)788-8333 ■ �,
1451 Concord Street Fax: (508)788-8334 �� � � ' I�
Framingham, MA 01701-7782 Contact: info(a�asbuiltes.com
USA Visit: www.asbuiltes.com Engineered Systems
O Copyright 2008 AsBuilt Engineered Systems, Inc.