HomeMy WebLinkAboutData Sheet 2816 IPF Series Dual Input Device Data Sheet 2816 /�l � B u I �t Engineered Systems IP Fire SeriesT"' Dual Point Identification � � Device �: � °. � � ��� �� :��, � ` �� � . • DXP-2 P I D a; �; . � :�� �___ _ . � .� _ ,:� ` T: Description '� � -.,z.�-,_ _. The IP Fire SeriesT"" control system provides for Analog Loop Modules (ALM's)that may be installed throughout a protected facility in any number up to the IPF system maximum of 50 modules. IPF SeriesT"' ALM modules offer analog addressable signaling line(SLC)circuits that Features may each have up to 126 detectors or 126 addressable control devices in any combination. • Dual Class A/B Input Circuits on a single address The AsBuilt Dual Priority Input Device(DXP-2PID)is an addressable . Monitors dry ContaCt devices dual switch monitor that is a means of connecting and identifying two • priority interrupt feature for conventional monitor point circuits at the main IPF SeriesT"' system. fast response DXP-2PID switch monitors connect to the SLC, are programmed via an 8 pin DIL switch (1-7 for addressing, 8 for Class A/B), are polarity • Dual LED's visible through the insensitive and are used to monitor one or two Class A or B (Style D or fascia plate label B)circuits. • Field programmable • Fully supervised The DXP-2PID are designed to monitor the state of one or more single- . Plate mounted for pole,volt-free contacts connected on a single pair of cables on two surface/flush mounting in 4" separate circuits. square boxes AsBuilt DXP-2PID switch monitors are available for surface/flush • LED for polling/alarm mounting in 4"square boxes. annunCiation • DIL switch addressing In standby mode,the DXP-2PID monitors its internal circuitry for status . Green/RoHS Compliant of the device itself and supervises both input circuits for faults. In the event a fault is detected,the DXP-2PID will report a trouble to the IPF SeriesT"" fire control. The DXP-2PID incorporates the priority interrupt feature on each of its two available circuits. Priority interrupt is used where a fast response is required (as with pull stations). Priority input devices produce output states of normal, off-normal and alarm.These devices do not produce pre-alarm output states. Terminal Block Assignments Listinqs TB1 L1 —Loop In/Out UL File: S7003 TB5 L2—Loop In/Out L1 and L2 non-polarized TB3 Switch Monitor Circuit Class A or B These devices all use end of line monitoring resistance of 47k'f2. Product Data Sheet Number Rev/Revision Date = _ IPF SeriesT"' Dual PID 2816 1.3/5/1/2009 IPFIRESERIES'" OO Copyright 2008 AsBuilt Engineered Systems, Inc. Enqineer Specification The contractor shall furnish and install,where indicated on the plans, addressable interface devices for the monitoring and supervision of contact type devices connected to the Fire Alarm control.The devices shall monitor one or two normally open dry contact circuits.The addressable interface devices shall communicate to the main fire control via the analog addressable circuit. The addressable interface device must be UL listed and UL listed as compatible with the AsBuilt IP Fire Series network fire controls. The addressable interface device shall be As Built Engineered Systems part numbers DXP-2PID. Technical Data Dual Priority Input Device: �imensions: Current Consumption: 600 NA typically Dimensions:4'/z"W x 4 '/z"H x 1 '/4"D LED on:4 mA Weight: 3 oz Operating Temp: -4°F to 158°F LED visible through fascia plate label Humidity: 0%to 95% (no condensation or icing) Shock: To UL 864 Vibration:To UL 864 Orderinq Information Part Number Data Sheet Description DXP-2PID 2816 Dual Priority Input Device(55000-790) Related Modules DXP-SDR 2814 Sounder Control Module (55000-825) DXP-IOM 2812 Input/Output Monitor(55000-820) DXP-OCM 2818 Output Control Module(55000-863) DXP-PIM 2810 Point Identification Module (55000-805) DXP-MPIM 2810 Mini Point Identification Module (55000-831) DXP-PID 2810 Priority Input Device (55000-806) DXP-MPID 2810 Mini Priority Input Device(55000-830) Related Data Sheets Discovery Detectors: DISC-P, 2106; DISC-I, 2107; DISC-T, 2108; DISC-M, 2109 XP Detectors: XP-P, 2101;XP-I, 2102;XP-T, 2103;XP-M, 2104 Addressable Base Options: All Bases,2310 Product Name Data Sheet Number Rev/Revision Date = _ _ IPF SeriesT"" Dual PID 2816 1.3/5/1/2009 IPFIRfSERIES" As Built Engineered Systems, Inc. Phone: (508)788-8333 ■ �, 1451 Concord Street Fax: (508)788-8334 �� � � ' I� Framingham, MA 01701-7782 Contact: info asbuiltes.com USA Visit: www.asbuiltes.com Engineered Systems O Copyright 2008 AsBuilt Engineered Systems, Inc.