Loading...
HomeMy WebLinkAboutData Sheet 2818 IPF Series Output Control Module Data Sheet 2818 /�l � B u I �t Engineered Systems IP Fire SeriesTM Output Control Module - �� ,�, .�,:��_ . � • DXP-OC M �� � �� M..�..u... _ . , � �� --__ . : _ Description Features The IP Fire SeriesT"^ control system provides for Analog Loop . Form C dry relay contacts Modules(ALM's)that may be installed throughout a protected Automatically controls facility in any number up to the IPF system maximum of 50 � modules. IPF SeriesT"^ ALM modules offer analog addressable building functions signaling line (SLC)circuits that may each have up to 126 • Fully supervised detectors or 126 addressable control devices in any combination. . Field programmable • Plate mounted for The AsBuilt output control monitor(DXP-OCM) is an addressable surFace/flush mounting in 4" device that is a means of connecting to and controlling building square boxes functions such as electromagnetic door holders, dampers, motors, LED for polling/alarm elevators and disconnects from the main IPF SeriesT"^ system. � annunciation The DXP-OCM connects to the SLC, is programmed via a 7 pin • DIL switch addressing DIL switch and is polarity insensitive. • Green/RoHS Compliant Single or multiple initiating points on the IPF SeriesT"' fire control are assigned to specific DXP-OCM modules that may be connected anywhere on the SLC. When an event is generated by an initiating device,the pre-programmed assignment automatically fires the Form C dry contacts located on the DXP- OCM effecting a change in status to the attached building control device(s). In standby mode, the DXP-OCM monitors its internal circuitry for status of the device itself and supervises the external control circuit for faults. In the event a fault is detected, the DXP-OCM will report a trouble to the IPF SeriesT"' fire control. When tied to specific smoke detectors, switch monitors and other initiating devices,the DXP-OCM allows the IPF SeriesT"^ fire Listinqs control to exercise significant automatic control over all building functions in accordance with local building requirements. UL File: S7003 The DXP-OCM is plate mounted on a 4'/4 x 4'/4 plastic plate for surface or flush mounting on 4"square boxes.The DXP-OCM is fully supervised,field programmable and has an integral LED that is visible through the front plate.The LED flashes on device poll to show that it is active.The red LED latches ON upon activation. Product Data Sheet Number Rev/Revision Date = _ IPF SeriesT"' Output Control Module 2818 1.3/5/1/2009 IPFIRESERIES'" OO Copyright 2008 AsBuilt Engineered Systems, Inc. Enqineer Specification The contractor shall furnish and install,where indicated on the plans, addressable interface devices for the monitoring, supervision and control of programmable relays connected to the Fire Alarm control. The devices shall act as an interface between the Fire Alarm control and building functions such as electromagnetic door holders, dampers, motors, elevators and disconnects and give the Fire Alarm the ability to change the state of the attached building control functions during an emergency condition . The addressable interface device shall communicate to the main fire control via the analog addressable circuit.The addressable interface device must be UL listed and UL listed as compatible with the AsBuilt IP Fire Series network fire controls. The addressable interface device shall be As Built Engineered Systems part numbers DXP-OCM. Technical Data All DeviCes: Dimensions: Current Consumption: 600 NA typically Dimensions:4'/z"W x 4 '/z"H x 1"D LED on:4 mA Weight: 3 oz Operating Temp: -4°F to 158°F LED visible through fascia plate label Humidity: 0%to 95% (no condensation or icing) Shock: To UL 864 Vibration:To UL 864 Orderinq Information Part Number Data Sheet Description DXP-OCM 2818 Output Control Module(55000-863) Related Modules DXP-PIM 2810 Point Identification Module (55000-805) DXP-MPIM 2810 Mini Point Identification Module (55000-831) DXP-PID 2810 Priority Input Device (55000-806) DXP-MPID 2810 Mini Priority Input Device(55000-830) DXP-IOM 2812 Input/Output Monitor(55000-820) DXP-SDR 2814 Sounder(55000-825) DXP-2PID 2816 Dual Priority Input Device(55000-790) DXP-OCM 2818 Output Control Module(55000-863) Related Data Sheets Discovery Detectors: DISC-P, 2106; DISC-I, 2107; DISC-T, 2108; DISC-M, 2109 XP Detectors: XP-P, 2101;XP-I, 2102;XP-T, 2103;XP-M, 2104 Addressable Base Options: All Bases,2310 Product Name Data Sheet Number Rev/Revision Date = _ _ IPF SeriesT"^ Output Control Module 2818 1.3/5/1/2009 IPFIRfSERIES" As Built Engineered Systems, Inc. Phone: (508)788-8333 ■ �, 1451 Concord Street Fax: (508)788-8334 �� � � ' I� Framingham, MA 01701-7782 Contact: info asbuiltes.com USA Visit: www.asbuiltes.com Engineered Systems O Copyright 2008 AsBuilt Engineered Systems, Inc.